Using the R&S FPL1000 Spectrum Analyzer is as intuitive as using a smartphone. Simple swiping gestures adjust the center frequency or the reference level. Two-finger gestures change the span or the displayed power level, while the 10.1″ screen with 1280×800 pixel resolution provides a clear display of the signal. Furthermore, the user can freely arrange the layout of the measurement results on the display.
Using the MultiView display mode, even different measurement modes can be combined and all the results can be displayed on one screen
Its light weight and battery operation capability lets you take it anywhere to perform measurements. The optional battery pack provides three hours of operation.
Thanks to its rich set of accessories, the R&S®FPL1000 is suitable for field measurements. For transport, a protective hard cover is available as well as a padded carrying bag that allows the instrument to be operated while in the bag. A shoulder harness simplifies portable operation.
Key Facts:
► Frequency range 5 kHz to 3 GHz or 5 kHz to 7.5 GHz
► SSB phase noise: –108 dBc (1 Hz) at 10 kHz offset (1 GHz carrier)
► DANL with preamplifier: –166 dBm from 10 MHz to 2 GHz
► Lightweight with small footprint
► Battery or 12 V/24 V DC operation (option)
► Use with power sensors (option)
► 40 MHz analysis bandwidth (option)
► Analog and digital signal analysis (option)
► Internal generator (option)
► Gated sweep, narrowband resolution filters and spectrogram measurements as standard
Specifications in brief | ||
Frequency | ||
Frequency range | R&S®FPL1003 | 5 kHz to 3 GHz |
R&S®FPL1007 | 5 kHz to 7.5 GHz | |
Aging per year | 1 × 10–6 | |
with R&S®FPL1-B4 option | 1 × 10–7 | |
Frequency resolution | 0.01 Hz | |
Bandwidth | ||
Resolution bandwidth (–3 dB) | sweep filters | 100 kHz to 10 MHz in 1/2/3/5 sequence |
FFT filters | 1 Hz to 50 kHz in 1/2/3/5 sequence | |
I/Q demodulation bandwidth | 12.8 MHz | |
with R&S®FPL1-B40 option | 40 MHz | |
Displayed average noise level (DANL) | ||
RF preamplifier off | 5 MHz ≤ f < 3 GHz | typ. –152 dBm |
5 GHz ≤ f ≤ 7.5 GHz | typ. –143 dBm | |
RF preamplifier on (option R&S®FPL1-B22) | 10 MHz ≤ f < 2 GHz | typ. –166 dBm |
5 GHz ≤ f < 7 GHz | typ. –159 dBm | |
Intermodulation | ||
1 dB compression of input mixer | nom. +7 dBm | |
Third-order intercept point (TOI) | 300 MHz ≤ fin < 3 GHz | typ. +20 dBm |
3 GHz ≤ fin ≤ 7.5 GHz | typ. +18 dBm | |
Phase noise | f = 1 GHz, 10 kHz frequency offset | typ. –108 dBc (1 Hz) |
Total measurement uncertainty | 1 MHz ≤ f < 3 GHz | 0.5 dB |
3 GHz ≤ f < 7.5 GHz | 0.8 dB |