MI 3108 EurotestPV is a high-quality photovoltaic tester and electrical installation safety tester in one. The Metrel PV string tester is capable of testing low voltage photovoltaic systems. In addition, the MI 3108 EurotestPV tester can perform all the necessary tests, such as insulation resistance current, voltage, power, insulation and continuity, module temperature, and more.
With Eurolink software, you can produce professional reports, which include measuring the performance of different PV modules, inverters, and more.
Metrel PV tester enables electrical installations to be completely tested according to EN 61557, as well as to carry out all the required tests for single-phase photovoltaic (PV) installations.
This includes all of the tests as required by EN 62446, but also includes I – U characteristic, Calculation of STC values as required by EN 61829 and power measurements on Inverter’s DC and AC sides.
MI 3108 EurotestPV is designed for working under demanding conditions (up to 1000 V, 15A DC). In order to enhance user safety, the MI 3108 EurotestPV comes with a PV Safety Probe that ensures safe disconnection every time.
Key features
Photovoltaic installations:
- Calculation of STC values: the measured current and voltage values are, according to environment conditions, recalculated to Standard Test Condition values which makes possible, to compare the results even if they were taken under different test conditions.
- Graphical representation: the I-V characteristic of PV module or string is graphically represented on LCD display.
- Power and efficiency measurements: 2 voltage & 2 current channels for simultaneous AC & DC parameters measurements.
- PV Remote Unit: Optional unit for simultaneous measurements of solar irradiation and temperature of PV module.
Electrical installations:
- RCD Auto: Automated RCD testing procedure significantly reduces test time.
- Trip Lock function: Loop impedance test are performed without tripping the RCD.
- B type RCD testing: is supported.
- Earth resistance measurement: instrument supports 3-wire earth resistance testing.
- Built-in fuse tables: for automatic evaluation of the line / loop impedance results.
- Online voltage monitoring: monitors all 3 voltages in real time.
- Scope function: real-time U/I scope.
- Harmonics analysis: 1-phase power and energy measurements with up to 11th harmonics analysis is supported.
- Memory: Up to 1800 test results or up to 500 graphical results with timestamp can be stored in internal memory.
- BT connectivity: it enables BT communication with Android tablets and smart phones via optional BT dongle.
- Android application: enables advanced data management APP EuroLink PV and EuroLink Android.
- PC SW EuroLink PRO enables downloading, uploading, review, analyses and printing of test results.
Measuring functions
Photovoltaic installations:
- Measurements on DC side of PV installation:
- Voltage, current, power;
- Uoc (Open Circuit Voltage) and Isc (Short Circuit Current);
- I – U curve of PV modules and strings;
- Irradiance;
- Module temperature.
- Measurements on AC side of PV installation:
- Voltage, current, power;
- Efficiency of PV module, inverter, PV system calculation.
Electrical installations:
- Insulation resistance;
- Continuity of PE conductors;
- Line impedance;
- Loop impedance (sub-functions with high current and without RCD tripping);
- RCD testing (type AC, A and B);
- Earth resistance;
- AC current (load and leakage);
- TRMS voltage, frequency, phase sequence;
- Power, energy, harmonics.
Standards applied
Building LV Installation
- EISinsp Competences: Low Voltage Electrical Installation Safety Inspection
- EISc Competences: Low Voltage Electrical Installation Safety for Contractors and Maintainers
- IEC/EN 60364 Electrical Installations for Buildings series
- IEC/EN 60364-4-41 Electrical Installations for Buildings – Protection against electric shock
- IEC/EN 61008-1 Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs)
- IEC/EN 61557 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC – Equipment for testing, measuring or monitoring of protective measures – series
- IEC/EN 61557-1 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC – Equipment for testing, measuring or monitoring of protective measures – Part 1: General requirements
- IEC/EN 61557-2 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC – Equipment for testing, measuring or monitoring of protective measures – Part 2: Insulation resistance
- IEC/EN 61557-3 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC – Equipment for testing, measuring or monitoring of protective measures – Part 3: Loop impedance
- IEC/EN 61557-6 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC – Equipment for testing, measuring or monitoring of protective measures – Part 6: Effectiveness of residual current devices (RCD) in TT, TN and IT systems
- IEC/EN 61557-7 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC – Equipment for testing, measuring or monitoring of protective measures – Part 7: Phase sequence
- IEC/EN 61557-10 Electrical safety in low voltage distribution systems up to 1 000 v a.c. and 1 500 v d.c. – Equipment for testing, measuring or monitoring of protective measures – Part 10: Combined measuring equipment for testing, measuring and monitoring of protective measures
- BS 7671 IEE Wiring Regulations (18th edition)
Earthing and lightning protection
- LPSinsp Competences: Lightning Protection of Buildings Inspection
- LPSc Competences: Lightning Protection of Buildings for Contractors and Maintainers
- IEC 62305 Protection against lightning – series
- IEC/EN 61557-5 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC – Equipment for testing, measuring or monitoring of protective measures – Part 5: Resistance to earth
- IEC/EN 61557-4 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC – Equipment for testing, measuring or monitoring of protective measures – Part 4: Resistance of earth connection and equipotential bonding
Photovoltaic systems
- PVV Competences: Photo Voltaic Installations Safety/Quality
- IEC / HD 60364-7-712 Low Voltage Electrical Installation Safety – Special installtions and locations
- IEC/EN 62446 Photovoltaic (PV) systems – Requirements for testing, documentation and maintenance
- IEC/EN 61829 Crystalline silicon photovoltaic (PV) array – On-site measurement of I / V characteristics
Power quality
- PQA Competences: Power Quality Analyzing & Reporting
- IEC/EN 61557-12 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC – Equipment for testing, measuring or monitoring of protective measures – Part 12: Power metering and monitoring devices (PMD)
Instrument safety towards user
- IEC/EN 61010 Safety requirements for electrical equipment for measurement, control, and laboratory use – series
- IEC/EN 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 1: General requirements
EMC safety
- IEC/EN 61326 Electrical equipment for measurement, control and laboratory use – EMC requirements – series
- IEC/EN 61326-1 Electrical equipment for measurement, control and laboratory use – EMC requirements – Part 1: General requirements
- Instrument MI 3108 EurotestPV
- Large carrying bag
- Schuko-plug test cable
- Test lead, 3 x 1.5 m
- Test probe, 4 pcs (red, green, blue, black)
- Crocodile clip, 4 pcs (red, green, blue, black)
- Fastening clamp, 2 pcs
- PV Safety Probe
- PV MC3/4 male/female adapters
- AC/DC current clamp
- PV reference cell + cable adapter
- Temperature probe + cable adapter
- Power supply adapter + 6 NiMH batteries, type AA
- USB and RS232 – PS/2 cable
- PC SW EuroLink PRO
- Set of carrying straps
- Short instruction manual
- Instruction manual and handbook on CD
- Calibration certificate