The Yokogawa CA700 Pressure Calibrator has a basic accuracy of 0.01% of rdg on pressure measurement and 0.015% of rdg on Current / Voltage of the source and measurement portions of the CA700. The CA700 is the most accurate calibrator in the portable calibrator class. It also has the highest resolution and widest range of any hand held portable in its class with resolution of 0.001 kpa (200.00 kpa range) and a resolution of 0.0001 psi (29 psi range)
Applications for the Yokogawa CA700 include:
- Field calibration of differential pressure and pressure transmitters
- Pressure switch test
- Check and I/O adjustment of an electro-pneumatic converter
- 20 mA SIMULATE (two-wire transmitter simulator)
- Two-wire transmitter loop check
- Input command check and adjustment of recorders and controllers
Yokogawa CA700 Features:
- Achieves the highest accuracy in the portable class
- Available ranges:
- -80 to 200 kPa
- -80 to 1000 kPa
- -80 to 3500 kPa
- Basic accuracy:
- Pressure; 0.01% rdg
- Current/voltage; 0.015% rdg
- 0.001 kPa resolution
- Calibration procedures are embedded
- IP54 dustproof and waterproof
Yokogawa CA700 Calibrator Specifications: | |||
Pressure Measurement | CA700-E-01 | CA700–E–02 | CA700–E–03 |
Pressure Type | Gauge | ||
Measurement range: | Pos. : 0 to 200 kPa Neg. : -80 to 0 kPa | Pos. : 0 to 1000 kPa Neg. : -80 to 0 kPa | Pos. : 0 to 3500 kPa Neg. pressure: -80 to 0 kPa |
Measurement display range: | To 240.000 kPa | To 1200.00 kPa | To 4200.00 kPa |
Resolution: | 0.001 kPa | 0.01 kPa | 0.01 kPa |
Meas. accuracy 6mo.: Positive pressure: | 20 to 200 kPa: ±(0.01% of rdg + 0.003 kPa) 0 to 20 kPa: ±(0.005 kPa) | (0.01% of rdg + 0.04 kPa) | ±(0.01% of rdg + 0.15 kPa) |
Meas. accuracy 6mo.: Negative pressure: | ±(0.2% of rdg + 0.080 kPa) | ±(0.2% of rdg + 0.08 kPa) | ±(0.2% of rdg + 0.08 kPa) |
Meas. accuracy 1yr.: Positive pressure: | 20 to 200 kPa: ±(0.01% of rdg + 0.010 kPa) 0 to 20 kPa: ±0.012 kPa | ±(0.01% of rdg + 0.08 kPa | ±(0.01% of rdg + 0.30 kPa) |
Meas. accuracy 1yr.: Negative pressure: | ±(0.2% of rdg + 0.090 kPa) | ±(0.2% of rdg + 0.09 kPa) | ±(0.2% of rdg + 0.09 kPa) |
Response time: | 2.5 s or less | ||
Allowable input: | 2.7 kPa abs to 500 kPa gauge | 2.7 kPa abs to 3000 kPa gauge | 2.7 kPa abs to 4500 kPa gauge |
Internal volume: | Approx. 6 cm3 | ||
Temperature coefficient: | ±(0.001% of reading + 0.001% of full scale)/°C or less | ||
Influence of positional setup: | Zero-point drift ±0.3 kPa or less | ||
Measurement fluid: | Gas and liquid (non-corrosive, non-flammable, non-explosive, and non-toxic fluids) | ||
Measurement fluid temperature: | -10 to 50°C | ||
Pressure sensor: | Silicon resonant sensor | ||
Pressure sensor element: | Diaphragm | ||
Pressure display units: | kPa and other units (Pa, hPa, MPa, mbar, bar, atm, mmHg, inHg, gf/cm2, kgf/cm2, mmH2O@4°C, mmH2O@20°C, ftH2O@4°C, ftH2O@20°C, inH2O@4°C, inH2O@20°C, Torr, psi ) | ||
Input port: | Rc 1/4 or 1/4 NPT female thread (selectable | ||
Measurement unit material: | Diaphragm: Hastelloy C276 and input port: SUS316 |
Yokogawa CA700 General Specifications: | |
Display: | Dot matrix LCD (320×240 dots) c/w LED Backlight |
Display refresh rate; | Approx. 300ms (3 times/sec) |
Warm-up time: | Approx. 5 minutes |
Power Voltage: | Six alkaline AA batteries |
Battery life: | Approx. 35 hours when measuring current with the 24 V loop power supply OFF and approx 10 hours with the 24 V loop power supply ON |
Auto power-off: | Approx. 60 minutes (the function can be disabled) |
Insulation resistance: | 100 MΩ or more (500 VDC) between the input terminal and case and between the input port and case |
Withstand voltage: | 500 VAC for 1 minute between the input terminal and case and between the input port and case |
Protection grade: | IP54 dustproof and waterproof structure |
Dimensions: | Approx. 264 (W) x 188 (H) x 96 (D) mm, excluding protrusions |
Weight: | Approx. 2kg (including batteries |
Compliance standards: | Safety: EN61010-1, EN61010-2-030, contamination class 2 EMC: EN61326-1 Class A, EN55011 Class A Group 1 |
Operating temperature: | -10 to 50°C and 20 to 80%RH (no condensation) |
Storage temperature: | -20 to 60°C and 20 to 80%RH (no condensation) |
Interfaces: | Select and switch between USB A mass-storage device, USB mini-B communication device class, and mass storage class |
External sensor: | A dedicated external sensor can be connected via a connector. (Planned to be released in the future |
Accessories: | A set of 1.7m long black and red lead wires with alligator clips for generation and measurement, six alkaline AA batteries, R1 1/4” – 1/8” NPT female thread x 1, ferrite core x 2, R 1/4” – 1/4” NPT female thread x 1, accessory case, instruction manual (CD), startup guide, shoulder strap |