HT Italia HT4014 Features:
- AC current up to 400A
- AC/DC voltage up to 600V
- Resistance
- Continuity test
- Frequency
- Diode test
- Autorange
- Backlight
- Bargraph
- AutoPowerOFF
- Data HOLD
- MAX/MIN
- Low battery indication
HT Italia HT4014 Specifications:
| 1. ELECTRICAL SPECIFICATIONS | |
| DC VOLTAGE | |
| Range | 400mV to 600V |
| Resolution | 0.1mV to 1V |
| Accuracy | ±(0.8%rdg+2dgt) ±(1.0%rdg+2dgt) |
| Overload protection | 600VDC/AC RMS |
| Input impedance | 10MΩ |
| AC VOLTAGE | |
| Range | 400mV to 600V |
| Resolution | 0.1mV to 1V |
| Accuracy | ±(1.0%rdg+50dgt) (40 – 60 Hz) ±(1.0%rdg+3dgt) ±(1.2%rdg+3dgt) |
| Overload protection | 660V DC/AC RMS |
| AC CURRENT | |
| Range | 40A to 400A |
| Resolution | 0.01A to 0.1A |
| Accuracy | ±(2.0%rdg+10dgt) |
| Overload protection | 600A RMS (60 second) |
| RESISTANCE | |
| Range | 400Ω to 40MΩ |
| Resolution | 0.1Ω to 10kΩ |
| Accuracy | ±(1.0%rdg+5dgt) ±(1.0%rdg+3dgt) ±(3.0%rdg+3dgt) |
| Overload protection | 600VDC/AC RMS |
| 2.GENERAL SPECIFICATIONS | |
| Display | The liquid crystal display (LCD) is 3 ¾ digits with maximum reading 3999 counts. Decimal point and symbol indication Backlight function Analogical Bargraph Automatic polarity indication. |
| Function | DCV, ACV, ACA, OHM, HZ, Diode check and Audible continuity tests. |
| Measuring rate | 2 times per second; 20 times per second for analogical bargraph |
| Operating temperature | 5°C to 40 °C, 0 – 80 % R.H. |
| Storage temperature | -10°C to 60°C, 0 – 70 % R.H. |
| General informations | Indoor use Altitude up to 2000m Pollution degree: 2 Insulation: class 2 (double insulation) Max. diameter conductor size : 30 mm |
| Power supply | 2 x 1.5V IEC R03 AAA carbon-zinc or alkaline type batteries AutoPowerOFF function for more of 30 minutes of don’t work |
| Dimension | 205 (H) x 64 (W) x 39 (L) mm |
| Weight | 280 grams with batteries included. |
| Applied standards | LVD: EN 61010-1 CAT III 600V EMC: EN60326 |