FLUKE ii910 Precision Acoustic Imager

Leaks in compressed air, gas, steam and vacuum systems hurt both production uptime and the operations bottom line. And now there’s also an easy way to detect, locate and analyze partial discharge in one tool.

Tired of spending too much time detecting partial discharge?

Introducing the Fluke ii910 Precision Acoustic Imager, engineered to locate partial discharge, corona discharge as well as gas and vacuum leaks. The ii910 acoustic imaging camera’s groundbreaking technology is a cost efficient, safe, effective, and comfortable tool for teams who inspect and maintain power distribution and industrial high voltage equipment.

FLUKE ii910 Features

  • Quick and easy partial discharge detection and PD testing
  • Reduce outages and increase uptime
  • Cut costs and save energy everyday by finding and fixing PD
  • PDQ Mode to capture and analyze partial discharge

    Fluke ii910 Datasheet

REQUEST A DEMO AND WIN

If you would like more information regarding this product, simply email us here.

  • Enter your query
  • Drop files here or
    Accepted file types: jpg, gif, png, pdf, Max. file size: 1 MB, Max. files: 4.
    • This field is for validation purposes and should be left unchanged.

    Fluke ii910 Precision Acoustic Imager

    Finally, an easy way to detect, locate and analyze partial discharge in one tool

    Tired of spending too much time detecting partial discharge? Introducing the ii910 Precision Acoustic Imager, engineered to locate partial discharge, corona discharge as well as gas and vacuum leaks.

    The Fluke ii910 acoustic imaging camera’s groundbreaking technology is a cost efficient, safe, effective, and comfortable tool for teams who inspect and maintain power distribution and industrial high voltage equipment.

    The invisible threat….now you can see

    Partial discharge is a serious issue that teams monitor everyday. Whether you are scanning insulators, transformers, switch gears or high voltage powerlines you need to be sure that you spot a problem quickly and early.

    Partial discharge that goes unchecked can cause blackouts, fires, explosions, or death from arc flashes. In addition to the danger that this can pose to the environment and human lives, it also has a very steep price tag.

    Key areas to scan for Partial Discharge

    • Insulators
    • Transformers
    • High voltage powerlines
    • Switch gears
    • Arrestors
    • Busbars
    • High voltage coils
    • Breakers
    • Capacitors

    Fluke safety you can trust with performance you value

    The Fluke ii910 Precision Acoustic Imager is the perfect tool for high voltage electricians, electrical test engineers, and grid maintenance teams that are constantly inspecting & maintaining power distribution and industrial high voltage equipment.

    The ii910 provides a safe quick and easy way to detect and locate partial discharge in order to maintain high voltage equipment and prevent catastrophic events. With the SoundSightâ„¢ technology the ii910 translates the sounds that it hears into a visual representation so that you can quickly locate problem areas.

    The higher frequency capability of the ii910 allows for earlier detection to facilitate early maintenance planning that is why the ii910 has a frequency range of 2-100Khz.

    Find and fix before flash

    Partial discharge can cause a number of very serious and expensive problems from catastrophic equipment failure to lethal arc flashes. The only way to stop this from happening is to inspect and maintain the equipment properly. The ii910 Precision Acoustic Imager is built to make finding PD much more comfortable faster and easy.

    Gone are the days of wearing headphones and listening for very faint sounds or squinting at a small screen to locate issues. Everything you will need to locate issues from a large distance is in the ii910, no cords or other accessories hanging down and getting tangled. Simply pick it up, turn it on and start locating issues.

    Safety you expect with the rugged product you trust

    Safety is key when working on high voltage equipment and here at Fluke safety is all that matters, everything else is just a bonus. Due to the combination of specific microphone positions and a sophisticated algorithm the ii910 Precision Acoustic Imager can detect PD and Corona Discharge from 120 meters away.

    This means that you can stay even further than the required distance away while still being effective and efficient at finding all of the problem areas. With no external cords or dangling accessories the ii910 ensures that you wont get tangled up in any equipment as you do your rounds. In addition with the acoustic imaging technology being able to pick up reflections of sounds you don’t even need to have direct line of sight to locate a problem.

    This means you can locate PD without ever opening a cabinet.

    Find it quickly, find it easily with no training

    The ii910 is truly designed so that anyone can use it with little to no training. Simply turn on the ii910 with one button select your frequency range, or let the tool do that for you, and start scanning around immediately looking for PD or leaks. Once you find a concerning image of a sound you can take a video or a photo to be used later after you have added any text annotation. If you want to know more details about a specific leak or PD switch into PDQ or LeakQ.

     uptime while prioritizing team safety.

     Fluke ii910 and MecQ™, maintenance professionals can minimize the risk of unplanned downtime on conveyor systems. Timely identification of potential bearing failures allows for prompt maintenance, preventing costly disruptions. Additionally, the ii910 enables remote inspections, ensuring team safety and eliminating hazards. Optimize productivity and enhance conveyor system performance with the Fluke ii910 and MecQ™.

    LeakQ online reporting tool

    • Local PC installed application
    • No Leak Type selection (should be included at time of capturing the measurement)
    • Offers customization of reporting template