The SEW 7015IN High Voltage Insulation Tester is provided with a guard rail to eliminate surface leakage when testing insulation resistance of assets such as PILC cables. Internal data storage can hold 200 measurements, and the instrument’s optical USB to RS-232 transmission
port allows data export to PCs via SEW’s standard CD-supplied software.
Standard features of the SEW 7015IN High Voltage Insulation Tester include an AC/DC voltmeter as well as audible alarm for live circuits, auto ranging on all insulation resistance ranges with auto hold to freeze readings, bar graph display allowing visual observation of charging patterns, overload protection, calendar and auto-power off.
SEW 7015IN Features:
● Test Insulation Resistance up to 2 TΩ (2000GΩ).
● Short-circuit current up to 5mA.
● Microprocessor controlled.
● 30 insulation test voltages :
500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV,
3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV,
6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV,
9.5kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV,
12.5kV, 13kV, 13.5kV, 14kV, 14.5kV, 15kV
● AC/DC Voltmeter.
● PI (Polarization Index) indication.
● DAR (Dielectric Absorption ratio) indication.
● Auto-ranging on all insulation ranges.
● Backlight function.
● Bargraph indicates test voltage, rise and decay
can be observed.
● Menu driven.
● Visual and audible warning if external voltage is
present. (≥30Vac or ≥30Vdc).
● Auto-hold function to freeze the reading.
● Overload protection.
● Adjustment for testing time (duration) : 1~30 minutes.
● Auto-off.
● Calendar.
● Optical USB to RS-232 data transmission.
● 200 measurement results can be saved in the
memory and recalled on the display.
● Safety standard: EN 61010-1 CAT IV 600V
EN 61010-2-030
EN 61326-1
SEW 7015IN Specifications:
Test Voltage | From 500Vdc to 15kVdc Adjustable in 500V steps |
Preset buttons | 1kV, 5kV, 10kV, 15kV |
Insulation resistance | 70GΩ/0.5kV 70GΩ at 0.5kV~2TΩ at 15kV |
Accuracy | ±(5.0%rdg+5dgt) |
Resolution | 2GΩ : 0.001GΩ 20GΩ : 0.01GΩ 200GΩ : 0.1GΩ 2TΩ : 1GΩ |
Short circuit current | up to 5mA |
PI (Polarization Index) | V |
DAR (Dielectric Absorption Ratio) | V |
Voltmeter | ACV : 0~600V (50/60Hz) DCV : 0~600V Accuracy : ±(2.0%rdg+3dgt) Resolution : 1V |
Power source | Rechargeable battery |
AC Adapter | Input : 100-240V~ ,0.4A ,50-60Hz Output : 24V … 0.62A |
Dimensions | 430(L) x 324(W) x 127(D)mm |
Weight | Approx : 5kg |
Reviews
There are no reviews yet.