PROVA 23 Power Harmonics and Leakage Clamp Meter Features:
- True RMS value (V and A)
- Leakage Current Measurement at 10 μ A Resolution
- Harmonic Analysis (V and A) to the 99 th Order
- High Frequency Harmonic Analysis (up to 5/6 KHz)
- Non-interrupted Harmonic Analysis
- Analysis of Total Harmonic Distortion (THD-F)
- Analysis of Crest Factor (C.F.)
- Fast Peak Function (33 μ s and 39 μ s)
- Programmable CT Ratio (1 to 250)
- 100A
Measur
es:
- W, KW, H.P.
- VA, KVA, VAR, KVAR
- PF, Phase Angle ( Φ )
- Energy (mWH, WH, KWH)
- Analysis of Standby Power Consumption
- Balanced 3 Φ Power Quality
PROVA 23 Power Harmonics and Leakage Clamp Meter Specifications:
AC Watts:
(50 or 60 Hz, PF 0.6~1, CT=1, Voltage is greater than AC 4V, Current is greater than AC 1mA for mA range & Current is greater than AC 0.04A for A range.Specification applies to continuous waveforms) | |||||
Range (0 to 60A) | Resolution | Accuracy of Readings | |||
0.050 – 9.999 W | 0.001W | ±2% ± 0.025W | |||
10.00 – 99.99 W | 0.01W | ±2% ± 0.25W | |||
100.0 – 999.9 W | 0.1W | ±2% ± 2.5W | |||
1.000 – 9.999 KW | 0.001 KW | ±2% ± 0.025KW | |||
10.00 – 99.99 KW | 0.01 KW | ±2% ± 0.25KW | |||
100.0 – 999.9 KW | 0.1 KW | ±2% ± 2.5KW | |||
1000 – 9999 KW | 1 KW | ±2% ± 25KW | |||
Range (60 – 100A) | Resolution | Accuracy | |||
0.050 – 9.999 W | 0.001W | ±2% of VA ± 5dgts | |||
10.00 – 99.99 W | 0.01W | ±2% of VA ± 5dgts | |||
100.0 – 999.9 W | 0.1W | ±2% of VA ± 5dgts | |||
1.000 – 9.999 KW | 0.001 KW | ±2% of VA ± 5dgts | |||
10.00 – 99.99 KW | 0.01 KW | ±2% of VA± 5dgts | |||
100.0 – 999.9 KW | 0.1 KW | ±2%of VA ± 5dgts | |||
1000 – 9999 KW | 1 KW | ±2% of VA ± 5dgts |
AC VOLTS:
(Auto Range, True RMS, Crest Factor<4, Input Impedance 10 MΩ, Max. peak value 860VDC & Overload Protection AC 800V) | ||||
Range | Resolution | Accuracy of Readings (50/60Hz) | ||
5V – 250 V | 0.1 V | ±0.5% ± 5dgts | ||
250 V – 600 V | 0.1 V | ±0.5% ± 5dgts | ||
Range | Resolution | Accuracy of Readings (45-1KHz) | ||
5V – 250 V | 0.1 V | ±1.5% ± 5dgts | ||
250 V – 600 V | 0.1 V | ±1.5% ± 5dgts |
AC CURRENT:
(Auto Range, True RMS, Crest Factor<4, CT=1, Max. peak values 880mADC for mA range, | ||||
73.5ADC for A range, Overload Protection AC 600A) | ||||
Range | Resolution | Accuracy of Readings (50/60Hz) | ||
0.5 – 60mA | 0.01mA | ±0.5% ± 5dgts | ||
60 – 100mA | 0.01mA | ±0.5% ± 50dgts | ||
100 – 600 mA | 0.1 mA | ±0.5% ± 5dgts | ||
0.05 – 3 A | 0.001 A | ±0.5% ± 5dgts | ||
3 – 30 A | 0.01 A | ±0.5% ± 5dgts | ||
30 – 90 A | 0.01 A | ±1.0% ± 5dgts | ||
Range | Resolution | Accuracy of Readings (45-1KHz) | ||
0.5 – 60mA | 0.01mA | ±1.5% ± 5dgts | ||
60 – 100mA | 0.01mA | ±1.5% ± 50dgts | ||
100 – 600 mA | 0.1 mA | ±1.5% ± 5dgts | ||
0.05 – 3 A | 0.001 A | ±1.5% ± 5dgts | ||
3 – 30 A | 0.01 A | ±1.5% ± 5dgts | ||
30 – 90 A | 0.01 A | ±1.5% ± 5dgts |
HARMONICS:
Harmonics of AC Voltage in Percentage (1 to 99th order, minimum voltage at 50 or 60Hz is greater | |||||
than AC 80V. If the voltage is 0 at 50 or 60 Hz, all the percentage (%) display is 0.) | |||||
Range | Resolution | Accuracy | |||
1 – 10th | 0.1 % | ±0.7% of reading ±1% | |||
11 – 20th | 0.1 % | ±2% of reading ±1% | |||
21 – 50th (A range) | 0.1 % | ±5% of reading ±1% | |||
21 – 50th (mA range) | 0.1 % | ±10% of reading ±1% | |||
51 – 99th | 0.1 % | ±35% of reading ±1% | |||
Harmonics of AC Voltage in Magnitude (1 to 99th order, minimum voltage at 50 or 60 Hz is | |||||
greater than AC 80V) | |||||
Range | Resolution | Accuracy | |||
1 – 10th | 0.1 V | ±0.7% of reading ±7dgts | |||
11 – 20th | 0.1 V | ±2% of reading ±7dgts | |||
21 – 50th (A range) | 0.1 V | ±5% of reading ±7dgts | |||
21 – 50th (mA range) | 0.1 V | ±10% of reading ±7dgts | |||
51 – 99th | 0.1 V | ±35% of reading ±7dgts |
Harmonics of AC Current in Percentage (1 to 99th order, minimum current at 50 or 60 Hz is greater than 100mA for mA range, and greater than 1A for A range. If the current is 0 at 50 or 60 Hz, all the percentage (%) display is 0.) | |||||
Range | Resolution | Accuracy | |||
1 – 10th | 0.1 % | ±0.7% of reading ±1% | |||
11 – 20th | 0.1 % | ±2% of reading ±1% | |||
21 – 50th (A range) | 0.1 % | ±5% of reading ±1% | |||
21 – 50th (mA range) | 0.1 % | ±10% of reading ±1% | |||
51 – 99th | 0.1 % | ±35% of reading ±1% |
Power Factor (PF, ACV > 4V, AC mA > 1mA, AC A > 0.04A, Watt > 50 digits) | ||||||
Range | Resolution | Accuracy | ||||
0.000 – 1.000 | 0.001 | ±0.04 | ||||
Phase Angle (Φ, 50 or 60Hz) | ||||||
Range | Resolution | Accuracy | ||||
-180° to 180° | 0.1° | ± 2° | ||||
0° to 360° | 0.1° | ± 2° | ||||
Total Harmonic Distortion | ||||||
(THD-F with respect to the first (fundamental) harmonics, min. value in the range from 45 to 65Hz is greater than AC 80V, greater than 1A for A range, and greater than 100mA for mA range. Calculation is done over 1 to 50th Harmonics. If the voltage or current is 0 in the range from 45 to 65Hz, all the percentage (%) display is 0) | ||||||
Range (45~65Hz) | Resolution | Accuracy | ||||
0.0 – 20.0 % | 0.1% | ± 2% | ||||
20.0 – 100% | 0.1% | ±3% of reading ± 5% | ||||
100 – 999.9% | 0.1% | ±10% of reading ±10% | ||||
Peak Value of AC Periodic Voltage (peak value> 10V) or AC Periodic Current (peak value>10mA for mA range and peak value>0.5A for A range) for continuous | ||||||
waveform except for square wave: | ||||||
Range | Sampling Time | Accuracy of Reading | ||||
50 Hz | 39 μs | ± 5% ± 30 digits | ||||
60 Hz | 33 μs | ± 5% ± 30 digits | ||||
Crest Factor (C.F.) of AC Voltage (peak value > 10V) or AC Current (peak value> 10mA for mA range and peak value>0.5A for A range) for continuous waveform | ||||||
except for square wave: | ||||||
Range (45~65Hz) | Resolution | Accuracy of Readings | ||||
1.00 – 99.99 | 0.01 | ± 5% ± 30 digits |
Frequency (Hz) | ||||||||||||
Range | Resolution | Accuracy of Readings | Allowed Input | |||||||||
mA (45 – 65Hz) | 0.1Hz | ± 0.5Hz | 20mA to 1.2A | |||||||||
A (45 – 65Hz) | 0.1Hz | ± 0.5Hz | 1A to 100A | |||||||||
Sensitivity: > 20mA for mA range, > 3A for A range, and > 50V | ||||||||||||
General Specifications: | ||||||||||||
Conductor Size: | 30mm (approx.) | |||||||||||
Battery Type: | two 1.5V SUM-3 | |||||||||||
Display: | 4+2+2 digits LCD | |||||||||||
Range Selection: | Auto | |||||||||||
Overload Indication: | OL | |||||||||||
Power Consumption: | 10 mA (approx.) | |||||||||||
Low battery Indication: | | |||||||||||
Auto-Power-Off: | 30 minutes after power-on | |||||||||||
Update Time: | 2 times/second (display) | |||||||||||
No. Of Samples per Period | 512 (voltage or current); 256 (power) | |||||||||||
Temperature Coefficient (<18℃ or >28℃): | 0.15 x (Specified Accuracy) / ℃ | |||||||||||
Operating Temperature: | -10°C to 50°C | |||||||||||
Operating Humidity: | less than 85% relative | |||||||||||
Altitude: | up to 2000M | |||||||||||
Storage Temperature: | -20°C to 60°C | |||||||||||
Storage Humidity: | less than 75% relative | |||||||||||
Dimension: | 210mm (L) x 62mm (W) x 35.6mm (H) 8.3″ (L) x 2.5″ (W) x 1.4″ (H) | |||||||||||
Weight: | 200g (battery included) | |||||||||||
Accessories: | Test leads x 1 pair, Carrying bag x 1, Users manual x 1, Batteries 1.5V x 2 | |||||||||||
Option: | Alligator clips |