The MEGGER DLRO2 Low Resistance Ohmmeter can measure low resistance values across a wide range of applications, from railways and aircraft to industry components.
This tough device comes with a brand new ‘difference’ meter that allows repetitive measurements to be easily compared with an initial reference measurement. The difference meter also translates the percentage difference to a needle/pointer movement, making the changes clear to see.
If your applications require long test leads, then the Megger DLRO2 can provide this without compromising test speed or safety. It has a dedicated long lead test to optimise the output, and this long test lead function is able to provide up to 1 A of test current into 4 ohms resistance.
The Megger DLRO2, with its optional cable reel test leads, is therefore ideal for testing wind turbine and avionic lightning protection applications.
MEGGER DLRO2 Specifications
General Specifications | |
PHYSICAL Dimensions | 8.98 x 4.1 x 2.95 in. (228 x 105 x 75 mm) |
Display | Full LCD color screen with user configurable backlight |
Weight | 32 oz (905 grams) |
SAFETY AND ELECTRICAL PROTECTION | |
Safety rating | CATIII 600 V / CATIV 300 V to EN 61010, IEC 61010-031 : 2015, IEC 61010-030 Safety category rating valid to altitude of 9842 ft (3000 m) |
Live voltage | Active live voltage protection to 600 V between any test terminals without blowing a fuse. Live voltage warning on display and audible when >5 V is applied between any test terminals. Fuse protected to 1000 V, fuses are not user changeable. |
TEST CURRENT OUTPUT | |
Current ranges | 2 A, 1 A, 100 mA, 10 mA and 1 mA |
Maximum compliance output voltage | 3.24 V (1 A mode) 2.2 V (2 A mode) |
Current output accuracy | Normal and inductive mode: ±10 % Long lead test mode: +10 % -0% at all battery conditions except with low battery indication. |
Thermal EMF/Seebeck effect compensation | Yes, average of forward and reverse test current measurements |
LOW RESISTANCE MEASUREMENT | |
Resistance measurement test modes | Normal test mode, fast mΩ/long test lead mode and inductive test mode (resistance of inductive loads). |
Overall resistance range | 1 μΩ – 2000 Ω |
Max resistance across C terminals | 2 A with up to 1.1 Ω total resistance and 1 A with up to 3.2 Ω total resistance. |
Basic accuracy | Bi-directional test current mode: ± 1% ±2 digits. Uni-directional test current mode: ± 1% ± 10 digits. Inductive mode or unidirectional mode will introduce an undefined error if an external EMF is present. |
ENVIRONMENT | |
Noise immunity | Less than 1% ±20 digits additional error with 80 mV peak 50/60 Hz with on screen noise limit indicator. Less than 1% ±20 digits additional error with 80 mV peak 400 Hz with on screen noise limit indicator. |
EMC | IEC61326-1, industrial specification IEC61326-2-2 |
Dust and moisture ingress | IP54 to IEC60529 in use |
Altitude | Operational to 9842 ft (3000 m) |
Temperature | Operational range 32º F to 122º F (0 ºC to 50 ºC) Storage range -4º F to +122º F (-20 ºC to 50 ºC) |
Humidity | Operational to 95% Storage to 90% |
Power Supply | Rechargeable 6 x AA NiMH batteries with built-in fast charge (also has the ability to use non-rechargeable alkaline AA batteries (LR6) |
Battery charge time | < 4 hours |
Battery life | >1000 bi-directional tests at 2 A auto into a 1 Ω load |
BATTERY CHARGER ADAPTOR | |
Line input voltage | 100 to 240 V |
Line input frequency | 50 to 60 Hz |
Output | 12 V DC 1.2 A 14.4 W max |
Type | Travel adaptor/interchangeable plug adaptor |
Plug types | Australia |
CONNECTIONS | |
Test terminals | 4 x 4 mm shrouded sockets |
Battery charger | 2.5 mm DC jack connector |