Fluke 17B MAX Digital Multimeter – Accurate AC/DC Measurements, Input Alert™ Safety System, Compact Design

BUY NOW form My Meter

The Fluke 17B MAX Digital Multimeter offers reliable performance with AC/DC measurements up to 1000V, CAT III 600V safety rating, resistance, capacitance, and diode testing. Its Input Alert™ alarm ensures safety, while the compact design, bright display, and fine test leads provide accurate measurements for DIYers and professionals alike.

PDF Download Fluke 17B Max Datasheet

If you would like more information regarding this product, simply email us here.

  • Enter your query
  • Drop files here or
    Accepted file types: jpg, gif, png, pdf, Max. file size: 1 MB, Max. files: 4.
    • This field is for validation purposes and should be left unchanged.

    Fluke 17B MAX Digital Multimeter – Reliable, Accurate, and Safe

    The Fluke 17B MAX Digital Multimeter is the perfect tool for DIY enthusiasts, beginner electricians, and professionals in the electrical field. Offering robust functionality and a user-friendly design, it delivers accurate measurements while ensuring safety during operation. Whether you’re troubleshooting a circuit, testing electrical components, or working on electronics, the Fluke 17B MAX is the ultimate tool to have in your toolkit.

    Fluke 17B MAX Digital Multimeter - Accurate AC/DC Measurements, Input Alert™ Safety System, Compact Design

    Key Features of the Fluke 17B MAX Digital Multimeter

    • Wide Measuring Range
    • AC/DC Voltage: Up to 1000V
    • AC/DC Current: Up to 10A
    • Resistance, Continuity, and Capacitance Measurements
    • Capacitance Range: 2000uF
    • Frequency and Temperature Measurement
    • Enhanced Safety

    With a CAT III 600V safety rating and built-in overload protection, the Fluke 17B MAX ensures reliable performance while keeping you safe. It includes the innovative Input Alert™ Audible and Visual Alarm, which warns against incorrect test lead connections to prevent blown fuses and operational errors.

    • Precise and Efficient Testing

    The multimeter features test leads with fine tips, making it ideal for circuit board testing and precise measurements. It’s the perfect companion for electricians and electronics R&D professionals.

    • User-Friendly Design

    The 17B MAX has a large, easy-to-read display with a bright backlight for working in dim environments. Its simple interface allows users to wake the meter from sleep mode by pressing any button, saving time and energy.

    • Additional Functionalities

    Includes diode testing to identify faulty diodes and an audible continuity tester for quick diagnostics. The 17B MAX is designed with a focus on both convenience and performance.

    Why Choose the Fluke 17B MAX Digital Multimeter?

    The Fluke 17B MAX continues the legacy of the 17B+ with significant improvements, making it one of the most reliable multimeters in its class. It is designed to meet the needs of electricians, technicians, and DIY hobbyists who demand accuracy and safety. With its Input Alert™ technology, incorrect connections are detected instantly, reducing the risk of errors and ensuring more productive workflows.

    Fluke 17B MAX Digital Multimeter - Accurate AC/DC Measurements, Input Alert™ Safety System, Compact Design in use

    Built for Safety and Performance

    Switching to an incorrect function while the test leads are in the current terminals is a common mistake that can damage the multimeter. With Fluke’s Input Alert™ system, you’ll receive real-time audible and visual warnings that help protect the meter, prevent blown fuses, and reduce downtime.

    Order the Fluke 17B MAX Today!

    Ready to enhance your electrical testing capabilities? The Fluke 17B MAX Digital Multimeter is your dependable partner for accurate measurements and safe operation. Buy now and experience the difference in performance and durability that Fluke is known for. Perfect for both professionals and beginners, the Fluke 17B MAX is built to handle every challenge with ease.

    Specifications

    Specifications: Fluke 17B MAX Digital Multimeter

    Specifications
    Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 % Accuracy specifications take the form of: ± ([% of Reading] + [Number of Least Significant Digits]).
    Function Range Resolution Accuracy
    15B MAX 17B MAX
    AC Volts (40 Hz to 500 Hz)1 6.000 V
    60.00 V
    600.0 V
    1000 V
    0.001 V
    0.01 V
    0.1 V
    1 V
    1.0 % + 3 1.0 % + 3
    AC Millivolts 600.0 mV 0.1 mV 3.0 % + 3 3.0 % + 3
    DC Volts 6.000 V
    60.00 V
    600.0 V
    1000 V
    0.001 V
    0.01 V
    0.1 V
    1 V
    0.5 % + 3 0.5 % + 3
    DC Millivolts 600.0 mV 0.1 mV 1.0 % + 10 1.0 % + 10
    AC Current μA (40 Hz to 400 Hz)2 400.0 μA
    4000 μA
    0.1 μA
    1 μA
    1.5 % + 3 1.5 % + 3
    AC Current mA (40 Hz to 400 Hz)2 40.00 mA
    400.0 mA
    0.01 mA
    0.1 mA
    1.5 % + 3 1.5 % + 3
    AC Current A (40 Hz to 400 Hz)2 4.000 A
    10.00 A
    0.001 A
    0.01 A
    1.5 % + 3 1.5 % + 3
    DC Current μA2 400.0 μA
    4000 μA
    0.1 μA
    1 μA
    1.5 % + 3 1.5 % + 3
    DC Current mA2 40.00 mA
    400.0 mA
    0.01 mA
    0.1 mA
    1.5 % + 3 1.5 % + 3
    DC Current A2 4.000 A
    10.00 A
    0.001 A
    0.01 A
    1.5 % + 3 1.5 % + 3
    Diode Test3 2.000 V 0.001 V 10% 10%
    Temperature 4 50.0 °C to 400.0 °C
    0 °C to 50.0 °C
    -55.0 °C to 0 °C
    0.1 °C NA 2 %+1 °C
    2 °C
    9 %+2 °C
    Resistance (Ohms)5 400.0 Ω
    4.000 kΩ
    40.00 kΩ
    400.0 kΩ
    4.000 MΩ
    40.00 MΩ
    0.1 Ω
    0.001 kΩ
    0.01 kΩ
    0.1 kΩ
    0.001 MΩ
    0.01 MΩ
    0.5 % + 3
    0.5 % + 2
    0.5 % + 2
    0.5 % + 2
    0.5 % + 2
    1.5 % + 3
    0.5 % + 3
    0.5 % + 2
    0.5 % + 2
    0.5 % + 2
    0.5 % + 2
    1.5 % + 3
    Capacitance6 40.00 nF
    400.0 nF
    4.000 μF
    40.00 μF
    400.0 μF
    2000 μF
    0.01 nF
    0.1 nF
    0.001 μF
    0.01 μF
    0.1 μF
    1 μF
    2 % + 5
    2 % + 5
    5 % + 5
    5 % + 5
    5 % + 5
    5 % + 5
    2 % + 5
    2 % + 5
    5 % + 5
    5 % + 5
    5 % + 5
    5 % + 5
    Frequency1 (10 Hz to 100 kHz) 50.00 Hz
    500.0 Hz
    5.000 kHz
    50.00 kHz
    100.0 kHz
    0.01 Hz
    0.1 Hz
    0.001 kHz
    0.01 kHz
    0.1 kHz
    NA 0.1 % + 3
    Duty Cycle1 1% to 99% 0.10% NA 1 % typical7
    Continuity Threshold 70Ω 70Ω
    Backlight Yes Yes
    1 All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
    2 Typical burden voltage: DC/AC Current µA: 100 µV / µA; DC/AC Current mA: 2 mV/mA; DC/AC Current A: 0.03 V/A
    3Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA
    4Use Type K thermocouple
    5 Typical open circuit test voltage is 0.54 V, maximum short circuit current is 1.8 mA
    6Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).
    7 Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10 % and 90 %.
    Input Characteristics
    Function Overload Protection Input Impedance (Nominal) Common Mode Rejection Ratio Normal Mode Rejection Ratio
    AC Volts 1000 V 1 >10 MΩ, <100 pF >60 dB at 50 Hz or 60 Hz
    AC Millivolts 1000 V 1 >1 MΩ, <100 pF >80 dB at 50 Hz or 60 Hz
    DC Volts 1000 V 1 >10 MΩ, <100 pF >100 dB at 50 Hz or 60 Hz >60 dB at 50 Hz or 60 Hz
    DC Millivolts 1000 V 1 >1 MΩ, <100 pF >80 dB at 50 Hz or 60 Hz
    1106 V Hz max
    General Specifications
    Maximum voltage between any Terminal and Earth Ground 600 V
    Maximum differential voltage between V and COM terminals 1000V
    Display (LCD) 6000 counts, updates 3/sec
    Battery Type 2 AA, IEC LR6
    Battery life 500 hours minimum
    Temperature Operating 0 °C to 40 °C;
    Storage -30 °C to 60 °C
    Relative Humidity Operating Humidity Non-condensing
    (<10 °C); ≤90 % RH at 10 °C to 30 °C;
    ≤75 % RH at 30 °C to 40 °C
    Operating Humidity, 40 MΩ range ≤80 % RH at 10 °C to 30 °C; ≤70 % RH at 30 °C to 40 °C
    Altitude Operating 2000 m; Storage 12000 m
    Temperature Coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
    Fuse protection for current inputs 440 mA, 1000 V, fast-blow, use only Fluke
    specified parts. 11 A, 1000 V, fast-blow,
    use only Fluke specified parts
    Size (HxWxL) 183 mm x 91 mm x 49.5 mm
    Weight 455 g
    Ingress Protection IP40
    Safety IEC 61010-1, IEC61010-2-030: CAT III
    600 V, Pollution Degree 2
    Electromagnetic Environment IEC 61326-1: Portable
    Electromagnetic Compatibility (EMC) Only applicable in Korea

    Class A Equipment (Industrial Broadcasting & Communication Equipment)1
    1Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.

    announcement  EOFY specials It's that time of the year again - the end of financial year! And here at Rapid-Tech, we've got some amazing EOFY specials for all our customers.