TDK-Lambda Genesys power supplies have been designed to meet the demands of a wide variety of applications. System Designers will appreciate new, standard, remote programming features such as Global commands. Also, new high-speed status monitoring is available for the RS-485 bus. Test Systems using the IEEE-488 bus may achieve significant cost savings by incorporating the Optional IEEE Multi-Drop Interface for a Master and up to 30 RS-485 Multi-Drop Slaves. Higher power systems can be configured with up to four 2.4kW modules. Each module is 1U with zero space
between them (zero stack).
Flexible configuration is provided by the complete Genesys Family: 1U 750W Half-Rack, 1U 750W and 1500W Full-Rack, 2U 3.3kW & 5kW. All are identical in Front Panel, Rear Panel Analog, and all Digital Interface Commands.
A wide variety of outputs allows testing of many different devices. OEM Designers have a wide variety of Inputs and Outputs from which to select depending on application and location.
These units can operate in either Constant-Current (CC) or Constant-Voltage (CV) mode with a user-friendly front panel interface (continuous encoders for FINE and COARSE adjustment and four-digit LED Voltage and Current meters) and provide safety features such as Safe/Auto Re-Start, Last Setting Memory and built-in protective functions (OVP, UVL, Current FOLDback, OTP and AC Low-Line). In addition, these models include two auxiliary Outputs (+5V Output @ 0.2A and +15V Output @ 0.2A) to simplify the setup of customer power supply control.
Applications
TDK-Lambda Genesys power supplies have been designed to meet the demands of a wide variety of applications. System Designers will appreciate new, standard, remote programming features such as Global commands. Also, new high-speed status monitoring is available for the RS-485 bus.
Test Systems using the IEEE-488 bus may achieve significant cost savings by incorporating the Optional IEEE MultiDrop Interface for a Master and up to 30 RS-485 Multi-Drop Slaves. Then up to 30 Slaves may be equipped with the less expensive Optional RS-485 Multi-Drop (MD) interface.
Higher power systems can be configured with up to four 2.4kW modules. Each module is 1U with zero space between them (zero stack). Flexible configuration is provided by the complete GenesysTM Family: 1U 750W Half-Rack, 1U 750W/1500W/2400W 2U 3.3kW/5kW, 3U 10/15kW Full-Rack. All are identical in Front Panel, Rear Panel Analog, and all Digital Interface Commands.
OEM Designers have a wide variety of Inputs and Outputs from which to select depending on application and location
TDK-Lambda Genesys Front Panel
1. ON/OFF Switch
2. Air Intake allows zero stacking for maximum system flexibility and power density.
3. Reliable encoder controls Output Voltage, Address, OVP and UVL settings.
4. Volt Display shows Output Voltage and directly displays OVP, UVL and Address settings.
5. Reliable encoder controls Output Current, sets baudrate and Advanced Parallel mode.
6. Current Display shows Output Current and displays Baud rate. Displays total current in Parallel Master/Slave Mode
7. Function/Status LEDs:
8. Pushbuttons allow flexible user configuration
- Coarse and Fine adjustment of Output Voltage/Current and Advanced Parallel Master or Slave select.
- Preview settings and set Voltage/Current with Output OFF, Front Panel Lock
- Parallel Master/Slave
- Set OVP and UVL Limits
- Set Current Foldback Protection
- Go to Local Mode and select Address and Baud rate
- Output ON/OFF and Auto-Re-Start/Safe-Start Mode
TDK-Lambda Genesys Rear Panel
1. Remote/Local Output Voltage Sense Connections.
2. DIP Switches select 0-5V or 0-10V Programming and other functions.
3. DB25 (Female) connector allows (Non-isolated) Analog Program and Monitor and other functions.
4. RS-485 OUT to other Genesys™ Power Supplies.
5. RS-232/RS-485 IN Remote Serial Programming.
6. Output Connections: Rugged busbars (shown) for up to 100V Output; wire clamp connector for Outputs >100V.
7. Exit air assures reliable operation when zero stacked.
8. Input: 230VAC Single Phase (shown), 208 VAC Three Phase, 50/60 Hz AC Input Connector: Phoenix P/N: FRONT-4-H-7.62.
9. Optional Interface Position for IEEE 488.2 SCPI (shown) or Isolated Analog Interface or LAN Interface.
10. Auxiliary Output Voltage Connector. Phoenix P/N: IMC1.5/7-ST-3.81
TDK-Lambda Genesys Specifications:
Model Number | Rated | Output | Output | Voltage Ripple | Ripple & Noise | Efficiency |
Power | Voltage | Current | mV RMS | mV p-p | % | |
(Watts) | (Volts) | (Amps) | (5Hz-1MHz) | (<20MHz) | (100/200VAC) | |
GEN 8-300 | 2400 | 0-8 | 0-300 | 8 | 60 | 84 |
GEN 10-240 | 2400 | 0-10 | 0-240 | 8 | 60 | 84 |
GEN 16-150 | 2400 | 0-16 | 0-150 | 8 | 60 | 86 |
GEN 20-120 | 2400 | 0-20 | 0-120 | 8 | 60 | 86 |
GEN 30-80 | 2400 | 0-30 | 0-80 | 8 | 60 | 88 |
GEN 40-60 | 2400 | 0-40 | 0-60 | 8 | 60 | 88 |
GEN 60-40 | 2400 | 0-60 | 0-40 | 8 | 60 | 88 |
GEN 80-30 | 2400 | 0-80 | 0-30 | 8 | 80 | 88 |
GEN 100-24 | 2400 | 0-100 | 0-24 | 8 | 80 | 88 |
GEN 150-16 | 2400 | 0-150 | 0-16 | 25 | 100 | 88 |
GEN 300-8 | 2400 | 0-300 | 0-8 | 50 | 200 | 88 |
GEN 600-4 | 2400 | 0-600 | 0-4 | 75 | 300 | 87 |