Additel 878 Reference Dry Well Calibrators
Welcome to the future of temperature calibration with the Additel 878 series, setting new benchmarks for performance and precision. Renowned for their versatility, these state-of-the-art dry well calibrators are designed to cater to your most demanding calibration needs with efficiency and accuracy. Whether you operate within industrial, laboratory, or field environments, the Additel 878 dry well series is your ultimate solution.
Premium Features and Flexibility
The Additel 878 Reference Dry Well Calibrators offer consistent performance across a comprehensive temperature range from -40°C to an impressive 700°C. Each of the three models, ADT878-160, ADT878-425, and ADT878-700, integrates seamlessly into your workflow to deliver unsurpassed calibration capabilities. These calibrators are crafted to be environmentally adaptive with a dual-zone control and a customizable process calibrator option designed to enhance your operational flexibility.
Unmatched Accuracy and Calibration
Boasting an industry-leading display accuracy, these dry wells represent the pinnacle of precision. The 878-160 model ensures accuracy within ±0.1°C across the full range, while both the 878-425 and 878-700 guarantee up to ±0.2°C. Additionally, each model is ISO 17025-accredited with traceable calibration data, ensuring reliability and confidence in every measurement.
Process Calibrator Option
Enhance the standard functionality of your calibrator with Additel’s Process Calibrator (PC) option. This feature incorporates an external reference input and two-channel readout, facilitating comprehensive measurement solutions for resistance temperature detectors (RTDs), thermocouples, and more. Capture critical data and communicate effortlessly with HART transmitters using onboard full HART documentation capabilities. Notably, our snapshot functionality empowers users to save real-time screen information with a single button press.
Self-calibration and Automation Features
The self-calibration function simplifies maintaining precision by employing an external reference probe. Experience the automation of this process with a few simple selections, thus ensuring fresh and traceable internal control sensor calibration. The 878 series also supports automated processes such as annealing, where the ADT878-700 is equipped with preconfigured and user-customizable annealing procedures to ensure the longevity and effectiveness of PRTs.
Revolutionary Triple Point of Water Realization
As a pioneer in automation, Additel introduces an automatic Triple Point of Water (TPW) realization feature with the ADT878-160. When coupled with the ADT878-TPW-KIT, this model effortlessly maintains your TPW cells, conducting assessments with incredible ease. This capability proves especially beneficial for verifying PRT drift over time, effectively reducing time and effort typically required in traditional TPW methods.
Why Choose Additel 878?
Selecting the Additel 878 series means investing in precision, reliability, and adaptive innovation. Whether you need the temperature control from -40°C to 160°C offered by the 878-160, the expansive range of 33°C to 425°C provided by the 878-425, or the high-temperature capacity of the 878-700 extending up to 700°C, you get an unmatched combination of cutting-edge technology and user-centric design.
Elevate your calibration capabilities today with Additel 878 Reference Dry Wells—where performance meets precision. Explore our extensive data sheets and experience unparalleled service and support, setting a new standard within the realm of temperature calibration equipment.