Key Features:
- Upgradable Bandwidth from 200MHz to 1.5GHz.
- 1,000,000 Waveform update rate
- Segmented Memory, allows greater flexibility in managing Memory depth for burst or long duration Signals capture & Analysis.
- InfiniiScan Zone touch trigger, “Precise Triggering capabilities”
- 12.1-inch display. Capacitive Touch Screen
- Optional Built-in 4 Channel 20MHz Waveform Generator (DSOX4WAVEGEN2).
- Software upgrades for embedded serial decode and trigger plus Mask Limit testing
- BenchVue Software with the BV0004B BenchVue Oscilloscope app (standard) allows control and display of multiple measurements simultaneously.
DSOX4024A, DSOX4034A, DSOX4054A, DSOX4104A and DSOX4154A are 4 Channel 200MHz (base Bandwidth) Oscilloscopes. The DSOX4024A can be upgraded at time of purchase to 350MHz, 500MHz 1GHz OR 1.5GHz via upgrades in the future. Waveform update rate is 1,000,000 waveforms / sec, Maximum Sample rate is 5GS/s.
All DSOX4000A series have Segmented memory, inbuilt Frequency counter and DVM.
Waveform Generator & Serial Trigger and Decode are available as options.
BenchVue Software with the BV0004B BenchVue Oscilloscope app (standard) lets you control and visualize multiple measurements simultaneously.
When you see anomalies, all you have to do is draw a zone box to trigger on them.
12.1-inch multi-touch capacitive display with gesture support
The 4000 X-Series captures a glitch occurring once in a million waveform cycles.
The 4000 X-Series provides the capabilities of five instruments seamlessly integrated into one.
Multi-domain analysis: Time-correlate analog, digital, and frequency domain signals
Viewing the frequency content of waveforms is greatly simplified by a touch screen operation. Pop up keypads make inputting start, stop, span and center frequency easy.And the new problem solving feature called “gated FFT” lets you time correlate the analog, digital, and frequency domain to aid in analysis and debug. In addition, there are new capabilities for peak searching, max and min hold and averaging of FFTs to increase dynamic range.
When gated FFT is on, the oscilloscope goes into zoom mode.The FFT analysis shown in the zoomed (bottom) window is taken from the period of time indicated by the zoom box in the main (top) window. In the gated FFT mode, touch and flick the zoom box through the acquisition to investigate how the FFT analysis changes over time, correlating the RF phenomenon with the analog and digital phenomenon.
Serial protocol analysis: Hardware-based serial protocol decode and triggering
Keysight InfiniiVision Series, including the new 4000 X-Series, are the only oscilloscopes to use hardware-based serial protocol decoding.Other vendors’ oscilloscopes use software post-processing techniques to decode serial packets⁄ frames, and therefore have slow waveform and decode capture rates and could miss critical events and errors due to a long dead-time.Faster decoding with hardware-based technology enhances the probability of capturing infrequent serial communication errors.
After capturing serial bus communication, you can easily perform a search operation based on specific criteria and then quickly navigate to bytes/frames of serial data that satisfy that search criteria.The 4000 X-Series can decode two serial buses simultaneously using hardware-based decoding, and display the captured data in a time interleaved “lister”display.
Serial protocol decoding can be used simultaneously with segmented memory and zone touch triggering.
Dual-channel WaveGen 20-MHz function/arbitrary waveform generator
The 4000 X-Series offers the industry’s first dual-channel, integrated 20-MHz function/arbitrary waveform generator.(DSOX4WAVEGEN2) The integrated generator provides stimulus output of sine, square, ramp, pulse, DC, noise, sine cardinal (sinc), exponential rise, exponential fall, cardiac, Gaussian pulse and arbitrary waveforms (AWG) to your device under test.Signal modulation capability is also available.
With AWG functionality, you can store waveforms from analog channels or reference memory to the arbitrary memory and output from WaveGen.Easily create and edit the waveform using the built-in editor or Keysight’s BenchLink Waveform Builder Basic software: www.keysight.com/find/33503.
With dual channels, you can generate differential signals to: output arbitrary clock and data signals to simulate serial buses, create complex modulations (more than the standard modulation feature), output IQ signals and more.The two channels can be tracked together as well (identical frequency, amplitude, offset and duty cycle).
Mixed signal oscilloscope (MSO): Integrated 16 digital channels
With an additional 16 integrated digital channels, you now have up to 20 channels of time-correlated triggering, acquisition and viewing on the same instrument.This is especially important in today’s embedded designs with sophisticated digital control circuitry. Unlike other oscilloscopes in this class, you can buy a 2- or 4-channel DSO and enable the 16 digital channels already in the instrument at any time to make it an MSO. (DSOXPERFMSO)
Power measurements and analysis
When you are working with switching power supplies and power devices, the Power Software Package (D4000PWRA) provides a full suite of power measurements and analysis in the oscilloscope.
To learn more about power supply testing, go to www.keysight.com/find/D4000PWRA.
Power measurements and analysis
When you are working with switching power supplies and power devices, the Power Software Package (D4000PWRA) provides a full suite of power measurements and analysis in the oscilloscope.
To learn more about power supply testing, go to www.keysight.com/find/D4000PWRA.
USB 2.0 signal quality analysis
In addition to triggering on and decoding low-speed, full-speed, and hi-speed USB 2.0 signals (hi-speed trigger & decode require a 1.0 or 1.5 GHz model), the optional USB Software Package (D4000USBA) also supports USB 2.0 signal quality testing (hi-speed tests require the 1.5 GHz model).The USB 2.0 signal quality test with HTML pass/fail report generation includes eye-diagram mask testing, jitter analysis, EOP bit-width, signaling rate, edge monotonicity, and rise/fall times; all based on official USB-IF algorithms embedded in the oscilloscope.
To learn more about USB signal quality testing, go to www.keysight.com/find/D4000USBA.
USB 2.0 signal quality analysis
In addition to triggering on and decoding low-speed, full-speed, and hi-speed USB 2.0 signals (hi-speed trigger & decode require a 1.0 or 1.5 GHz model), the optional USB Software Package (D4000USBA) also supports USB 2.0 signal quality testing (hi-speed tests require the 1.5 GHz model).The USB 2.0 signal quality test with HTML pass/fail report generation includes eye-diagram mask testing, jitter analysis, EOP bit-width, signaling rate, edge monotonicity, and rise/fall times; all based on official USB-IF algorithms embedded in the oscilloscope.