<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Carbon Monoxide Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/product-tag/carbon-monoxide/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/product-tag/carbon-monoxide/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Tue, 03 Jun 2025 03:28:51 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.7</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>Carbon Monoxide Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/product-tag/carbon-monoxide/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>REED R9450 Carbon Monoxide Monitor with Temperature and Humidity &#8211; &#124; REED</title>
		<link>https://rapid-tech.com.au/reed-r9450-carbon-monoxide-monitor-with-temperature-and-humidity-reed/</link>
					<comments>https://rapid-tech.com.au/reed-r9450-carbon-monoxide-monitor-with-temperature-and-humidity-reed/#respond</comments>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Wed, 08 Jun 2022 23:04:45 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=22298</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-980" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/reed-logo-red.jpg" alt="reed logo red" width="120" height="50" /></p>
<p>The REED R9450 Carbon Monoxide Monitor with Temperature and Humidity is a must-have for any home, vehicle, or office. This reliable monitor simultaneously displays carbon monoxide levels, ambient temperature, relative humidity, time and date on a clear, multi-line LCD screen. It also features an adjustable alarm limit.</p>
<h4><img class="alignnone size-full wp-image-19718" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" />  <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2022/06/REED-R9450-Datasheet.pdf" rel="noopener">REED R9450 Datasheet</a></h4>
<p>The post <a href="https://rapid-tech.com.au/reed-r9450-carbon-monoxide-monitor-with-temperature-and-humidity-reed/">REED R9450 Carbon Monoxide Monitor with Temperature and Humidity &#8211; | REED</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p id="84aca7e4-aa7b-4403-b920-88711a55f84d" class="quill-block">With the REED R9450, you can rest assured that you and your loved ones are safe from the dangers of carbon monoxide poisoning. Place it in a central location such as the living room or kitchen to easily monitor CO levels at all times. Order yours today and breathe easier knowing you&#8217;re protected from this invisible threat.</p>
<p id="84aca7e4-aa7b-4403-b920-88711a55f84d" class="quill-block">This easy-to-use monitor is capable of detecting concentrations of carbon monoxide up to 999ppm, making it ideal for use in homes, offices, and other commercial settings.</p>
<p id="84aca7e4-aa7b-4403-b920-88711a55f84d" class="quill-block">The R9450 features a large LCD display that shows both the current CO level and the temperature, as well as a built-in clock and calendar. The max hold function ensures you always know the highest CO concentration that has been detected, while the user-adjustable alarm limit lets you customize the device to your specific needs.</p>
<p id="84aca7e4-aa7b-4403-b920-88711a55f84d" class="quill-block">REED is a trusted name in environmental monitoring, so you can rest assured that the R9450</p>
<div class="epyt-video-wrapper"><iframe  id="_ytid_12416"  width="1020" height="574"  data-origwidth="1020" data-origheight="574"  data-relstop="1" src="https://www.youtube.com/embed/YMEow2BQvIs?enablejsapi=1&autoplay=0&cc_load_policy=0&cc_lang_pref=&iv_load_policy=1&loop=0&rel=0&fs=1&playsinline=1&autohide=2&theme=dark&color=red&controls=1&disablekb=0&" class="__youtube_prefs__  no-lazyload" title="R9450 Carbon Monoxide Monitor with Temperature and Humidity"  allow="fullscreen; accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen data-no-lazy="1" data-skipgform_ajax_framebjll=""></iframe></div>
<p>&nbsp;</p>
<p>The post <a href="https://rapid-tech.com.au/reed-r9450-carbon-monoxide-monitor-with-temperature-and-humidity-reed/">REED R9450 Carbon Monoxide Monitor with Temperature and Humidity &#8211; | REED</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/reed-r9450-carbon-monoxide-monitor-with-temperature-and-humidity-reed/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Multiple Gas Detector &#124; CEM GD-3803</title>
		<link>https://rapid-tech.com.au/multiple-gas-detector-cem-gd-3803/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Wed, 15 Sep 2021 04:18:52 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=19773</guid>

					<description><![CDATA[<p><img class="alignnone wp-image-18520" src="https://rapid-tech.com.au/wp-content/uploads/2021/06/CEM-logo-white-300x105.png" alt="CEM logo" width="231" height="81" /></p>
<p>&#160;</p>
<p><a target="_blank" href="https://mymeter.com.au/product/handheld-multiple-gas-detector-cem-gd-3803/" rel="noopener"><img class="alignnone size-full wp-image-17843" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/BUY-NOW-form-My-Meter-e1620004827208.png" alt="Buy now form My Meter" width="220" height="55" /></a></p>
<p>The CEM GD-3803 is a handheld multiple gas detector capable of measuring and recording Oxygen (O2), Carbon Monoxide (CO), Carbon Dioxide (CO2), as well as air temperature and humidity. The device has a rechargeable battery and can save up to 500 data points.</p>
<h4><img class="size-full wp-image-19718 alignnone" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" />  <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2021/09/CEM-GD-3803-Datasheet.pdf" rel="noopener">CEM GD-3803 Datasheet</a></h4>
<p>The post <a href="https://rapid-tech.com.au/multiple-gas-detector-cem-gd-3803/">Multiple Gas Detector | CEM GD-3803</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span style="font-weight: 400;">The CEM GD-3803 is a multifunction handheld GAS meter that can measure and record Oxygen (O2), Carbon Monoxide (CO), Carbon Dioxide (CO2), as well as air temperature and humidity. It comes with relational software for downloading data and data logging, as well as for programming. The CEM GD-3803 handheld device has a rechargeable battery and can save up to 500 data points.</span></p>
<h4>FEATURES</h4>
<ul>
<li>Oxygen Measurement</li>
<li>Carbon Monoxide Measurement</li>
<li>Carbon Dioxide Measurement</li>
<li>Air Temperature Measurement</li>
<li>Humidity Measurement</li>
<li>500 Data Points</li>
<li>Rechargeable Battery</li>
<li>MIN, MAX, AVG, HOLD Display</li>
<li>Temperature Unit Converter</li>
<li>Auto Power Off</li>
<li>Record Data</li>
<li>Query Data</li>
<li>Backlight</li>
<li>Record Time</li>
</ul>
<p>The post <a href="https://rapid-tech.com.au/multiple-gas-detector-cem-gd-3803/">Multiple Gas Detector | CEM GD-3803</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Combustible Gas Leak Detector &#124; CEM GD-3308</title>
		<link>https://rapid-tech.com.au/combustible-gas-leak-detector-cem-gd-3308/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Thu, 24 Jun 2021 02:14:02 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=18665</guid>

					<description><![CDATA[<p><img class="alignnone wp-image-18520" src="https://rapid-tech.com.au/wp-content/uploads/2021/06/CEM-logo-white-300x105.png" alt="CEM logo" width="231" height="81" /></p>
<p>&#160;</p>
<p><a target="_blank" href="https://mymeter.com.au/product/combustible-gas-leak-detector-cem-gd-3308/" rel="noopener"><img class="alignnone size-full wp-image-17843" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/BUY-NOW-form-My-Meter-e1620004827208.png" alt="Buy now form My Meter" width="220" height="55" /></a></p>
<p><strong>Combustible Gas Leak Detector - Carbon Monoxide Meter Co Detector</strong></p>
<p>GD 3308 Combustible Gas Leak Detector detects the presence of combustible gas and measures concentrations between 0~10000 parts per million (PPM).</p>
<p><strong>Features</strong></p>
<ul>
<li>Highly sensitive and reliable</li>
<li>inpoint small Leaks: Detects all combustible gas leaks even tiny leaks</li>
<li>Auto Zero</li>
<li>Highly Accuracy, quick response</li>
<li>Auto power off</li>
<li>LCD display</li>
<li>16" Adjustable Probe</li>
<li>Repiaceabie Sensor</li>
<li>TRI Mode Detection</li>
</ul>
<p><img class="alignnone size-full wp-image-17809" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-Download-e1620015214396.png" alt="PDF Download icon" width="51" height="60" /> <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2021/06/CEM-GD-3306_08-Combustible-Gas-Detector.pdf" rel="noopener">GD-3306 Datasheet</a>    <img class="alignnone size-full wp-image-17809" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-Download-e1620015214396.png" alt="PDF Download icon" width="51" height="60" /> <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2021/06/GD-3308v161229A6.pdf" rel="noopener">GD-3308 User Manual</a></p>
<p>The post <a href="https://rapid-tech.com.au/combustible-gas-leak-detector-cem-gd-3308/">Combustible Gas Leak Detector | CEM GD-3308</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The CEM GD-3308 Combusitbie Gas Leak Detecor Combustible Gas Detector is a gas leak locating tool that is used to identify the presence of and isolate the source location of combustible gases such as methane, propane, butane, ammonia, carbon monoxide and many others(please see back of manual for a more complete list). Even low levels of combustible gas can be detected in seconds.</p>
<p>The micro MICRO Combusitbie Gas Leak Detecor detects gas concentrations through the use of an internal sensor. This sensor is heated during operation. As the heated sensor interacts with gases, the unit immediately indicates to the user that combustible gases are present.</p>
<p>The GD-3308 Combusitble Gas Leak Detecor indicates the presence of combustible gases with visual, audio and vibration feedback mechanisms. It can detect different combustible gas concentration 1-1 OOOppm or 0-1 OOOOppm by setting high and low concentration detection. When the tool senses the presence of a combustible gas, it will tell the operator by LCD display, triggering the appropriate audible alert or providing the appropriate vibration alert. The GD-3308 Combusitbie Gas Leak Detecor comes equipped with an attached flexible 16&#8243;probe hose.</p>
<p>The post <a href="https://rapid-tech.com.au/combustible-gas-leak-detector-cem-gd-3308/">Combustible Gas Leak Detector | CEM GD-3308</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Flue gas analyzer (O2, CO up to 4,000 ppm) &#124; Testo 300 Domestic Kit</title>
		<link>https://rapid-tech.com.au/flue-gas-analyzer-o2-co-up-to-4000-ppm-testo-300-domestic-kit/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Thu, 20 May 2021 05:06:09 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=18340</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-13413" src="https://rapid-tech.com.au/wp-content/uploads/2019/12/Testo-Be-Sure-Logo.jpg" alt="" width="207" height="90" /></p>
<p>The Testo 300 flue gas analyzer is ideal for the most important measurements involving heating systems. It combines decades of experience in measuring technology with contemporary smart-touch operation, robust construction and e-mailing of reports.</p>
<p>The Testo 300 enables easy measurement of flue gas, draught, pressure, ambient CO and differential temperature.</p>
<ul class="list-elements">
<li>Intuitive measurement menus and the fast-response Smart-Touch display ensure easy operation – as on your smartphone</li>
<li>Including O<sub>2</sub> and CO sensor up to 4,000 ppm</li>
<li>Large 5-inch HD display – see all the system's measuring values at a glance</li>
<li>Creation of documentation directly on site and e-mailing of reports</li>
</ul>
<article class="child-1">
<h3>Kit components</h3>
</article>
<article class="child-1"><strong>testo 300 - Flue gas analyzer (O<sub>2</sub>, CO up to 4,000 ppm)</strong><br />
Order-Nr. 0633 3002 70</article>
<article class="child-1"><strong>Compact basic flue gas probe, 180 mm, Ø 6 mm, Tmax 500 °C</strong><br />
Order-Nr. 0600 9740</article>
<article class="child-1"><strong>Spare particle filter, compact probe; 10 off</strong><br />
<span style="color: #555555; font-size: 14.4px;">Order-Nr. 0554 0040</span></article>
<article class="child-1"><strong>testo EasyHeat v2.12 SP5 - PC software</strong><br />
<span style="color: #555555; font-size: 14.4px;">Order-Nr. 0554 3332</span></article>
<article class="child-1"><strong>Instrument bag with carrying strap</strong><br />
<span style="color: #555555; font-size: 14.4px;">Order-Nr. 0516 3001</span></article>
<article class="child-1"><strong>USB mains unit with cable</strong><br />
<span style="color: #555555; font-size: 14.4px;">Order-Nr. 0554 1106</span></article>
<p><img class="alignnone size-full wp-image-17809" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-Download-e1620015214396.png" alt="PDF Download icon" width="45" height="60" />  <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2019/12/Testo-300-Datasheet.pdf" rel="noopener">Testo 300 Datasheet</a></span></p>
<p><img class="alignnone size-full wp-image-17809" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-Download-e1620015214396.png" alt="PDF Download icon" width="45" height="60" /> <span style="text-decoration: underline; font-size: 100%;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2019/12/Testo-300-User-Manual.pdf" rel="noopener">Testo 300 User Manual</a></span></p>
<p>The post <a href="https://rapid-tech.com.au/flue-gas-analyzer-o2-co-up-to-4000-ppm-testo-300-domestic-kit/">Flue gas analyzer (O2, CO up to 4,000 ppm) | Testo 300 Domestic Kit</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<article class="child-1">
<div class="m-list">
<article><div class="epyt-video-wrapper"><iframe  id="_ytid_54122"  width="1020" height="574"  data-origwidth="1020" data-origheight="574"  data-relstop="1" src="https://www.youtube.com/embed/8JvCnxrJ7v4?enablejsapi=1&autoplay=0&cc_load_policy=0&cc_lang_pref=&iv_load_policy=1&loop=0&rel=0&fs=1&playsinline=1&autohide=2&theme=dark&color=red&controls=1&disablekb=0&" class="__youtube_prefs__  no-lazyload" title="The new testo 300 flue gas analyzer | Be sure. Testo"  allow="fullscreen; accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen data-no-lazy="1" data-skipgform_ajax_framebjll=""></iframe></div></article>
<article><div class="epyt-video-wrapper"><iframe  id="_ytid_83583"  width="1020" height="574"  data-origwidth="1020" data-origheight="574"  data-relstop="1" src="https://www.youtube.com/embed/ackOfNr4W3Y?enablejsapi=1&autoplay=0&cc_load_policy=0&cc_lang_pref=&iv_load_policy=1&loop=0&rel=0&fs=1&playsinline=1&autohide=2&theme=dark&color=red&controls=1&disablekb=0&" class="__youtube_prefs__  no-lazyload" title="testo 300 flue gas analyzer - 360 view"  allow="fullscreen; accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen data-no-lazy="1" data-skipgform_ajax_framebjll=""></iframe></div></article>
<article><div class="epyt-video-wrapper"><iframe loading="lazy"  id="_ytid_41043"  width="1020" height="574"  data-origwidth="1020" data-origheight="574"  data-relstop="1" src="https://www.youtube.com/embed/lnv8smfEuJk?enablejsapi=1&autoplay=0&cc_load_policy=0&cc_lang_pref=&iv_load_policy=1&loop=0&rel=0&fs=1&playsinline=1&autohide=2&theme=dark&color=red&controls=1&disablekb=0&" class="__youtube_prefs__  no-lazyload" title="Flue gas measurement with the testo 300 flue gas analyzer"  allow="fullscreen; accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen data-no-lazy="1" data-skipgform_ajax_framebjll=""></iframe></div></article>
</div>
<p>The Testo 300 Flue gas analyzer is truly a smart flue gas measurement instrument for use on heating systems. High-quality sensors, intuitive operation with smart-touch technology and smart features, such as efficient documentation and e-mailing of reports, The Testo 300 will make your day-to-day work easier.</p>
<h3>Testo 300 flue gas analyzer with smart-touch operation</h3>
<h4><strong>Impressive measuring technology and quality</strong></h4>
<ul>
<li>O<sub>2</sub> sensor and CO sensor up to 4,000 ppm</li>
<li>Longer sensor service life thanks to automatic sensor protection</li>
<li>TÜV-tested according to first German Federal Immission Control Ordinance (BImSchV) and EN 50379, Parts 1-3</li>
<li>Integrated fine pressure</li>
<li>Versatile probes and fast probe changes: take advantage of quick-change probes and the multi-functional handle for attaching a variety of probe shafts (each available to order separately). You can for instance use longer probe shafts for flue gas pipes with larger diameters or flexible probes for difficult-to-access measuring points</li>
<li>Optionally available probes and accessories for further measuring tasks, such as gas flow pressure measurement, gas pipe testing, differential temperature measurement and ambient CO measurement</li>
</ul>
<h4> <strong>Smart, intuitive, efficient: easy operation in day-to-day work</strong></h4>
<ul>
<li>Smart-touch display for intuitive operation of the flue gas analyzer: the display responds without delay – just as easy as on your smartphone</li>
<li>Get the measurement result faster: clearly structured measurement menus for all relevant measurements</li>
<li>Create documentation (including measuring value, measuring location, customer data) easily on site</li>
<li>Save PDF measurement reports directly in the instrument and always have them available</li>
<li>Signature function: your customer can sign measurement reports directly on the instrument</li>
<li>E-mail measurement reports directly to the office or to customers via WLAN (hotspot)</li>
<li>Large 5-inch HD display – enables you to see all the system&#8217;s parameters immediately</li>
<li>Testo interface function for direct data transfer of measuring values to industry/customer-specific software*</li>
<li>Ready to use straight away: in standby mode, the testo 300 is ready to measure at the touch of a button. Use it straight away with the next customer – because you no longer need to wait for the end of the zeroing phase</li>
<li>Integrated Bluetooth<sup>®</sup> interface: immediate printout of the measuring values on site with the appropriate printer</li>
</ul>
<p>*Note: the manufacturer has to integrate an interface into the industry software to use the function</p>
<h4> <strong>Other advantages</strong></h4>
<ul>
<li>10-hour rechargeable battery life: an average measurement period of 2 hours means the flue gas analyzer is capable of being used for one week</li>
<li>Integrated, extra-strong magnets for easy fixing during the measuring process</li>
</ul>
<div class="is-divider divider clearfix" style="max-width:100%;"></div>
<h3 class="s4 title">Flue gas measurement on heating systems</h3>
<div class="row"  id="row-289328661">

	<div id="col-1961741381" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<p><strong>Ideal for measurements involving heating systems:</strong></p>
<ul>
<li>high-quality sensors, smart-touch operation, clearly structured measurement menus, creation of documentation on site, e-mailing of reports, large HD display, robust housing</li>
</ul>
<p><strong>Further areas of application:</strong></p>
<ul>
<li>gas flow pressure measurement*, gas pipe test*, differential temperature measurement (flow and return temperature on heating systems)*, ambient CO measurement*, flue draught measurement on heating systems*</li>
</ul>
		</div>
					</div>

	

	<div id="col-1470148736" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<p>&nbsp;</p>
<p><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-13471" src="https://rapid-tech.com.au/wp-content/uploads/2019/12/Testo-300-Fluegas-Measurement-300x217.jpg" alt="" width="300" height="217" srcset="https://rapid-tech.com.au/wp-content/uploads/2019/12/Testo-300-Fluegas-Measurement-300x217.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2019/12/Testo-300-Fluegas-Measurement-600x435.jpg 600w, https://rapid-tech.com.au/wp-content/uploads/2019/12/Testo-300-Fluegas-Measurement-768x557.jpg 768w, https://rapid-tech.com.au/wp-content/uploads/2019/12/Testo-300-Fluegas-Measurement.jpg 999w" sizes="auto, (max-width: 300px) 100vw, 300px" /><br />
		</div>
					</div>

	
</div>
<p><em>* Please note: additional probes or accessories are required for these measurements and have to be ordered separately.</em></p>
<div class="is-divider divider clearfix" style="max-width:100%;"></div>
<h2>Models, Probes and Accessories</h2>
<p>Refer to Testo 300 Datasheet for information on available models, probes and accessories.</p>
<div class="is-divider divider clearfix" style="max-width:100%;"></div>
<h2>Testo 300 Flue gas analyzer Specification</h2>
<table>
<colgroup>
<col class="colWidth25" />
<col /></colgroup>
<thead>
<tr>
<th colspan="2">Temperature &#8211; TC Type K (NiCr-Ni)</th>
</tr>
</thead>
<tbody>
<tr>
<td class="table-bold">Measuring range</td>
<td>-40 to +1200 °C</td>
</tr>
<tr>
<td class="table-bold">Accuracy</td>
<td>±0.5 °C (0.0 to +100.0 °C)</p>
<p>±0.5 % of mv (Remaining Range)</td>
</tr>
<tr>
<td class="table-bold">Resolution</td>
<td>0.1 °C (-40 to +999.9 °C)</p>
<p>1 °C (Remaining Range)</td>
</tr>
</tbody>
</table>
<table>
<colgroup>
<col class="colWidth25" />
<col /></colgroup>
<thead>
<tr>
<th colspan="2">Differential Pressure &#8211; Piezoresistive</th>
</tr>
</thead>
<tbody>
<tr>
<td class="table-bold">Measuring range</td>
<td>-100 to +200 hPa</td>
</tr>
<tr>
<td class="table-bold">Accuracy</td>
<td>±0.5 hPa (0 to +50.0 hPa)</p>
<p>±1 % of mv (+50.1 to +100.0 hPa)</p>
<p>±1.5 % of mv (+100.1 to +200 hPa)</td>
</tr>
<tr>
<td class="table-bold">Resolution</td>
<td>0.01 hPa</td>
</tr>
</tbody>
</table>
<table>
<colgroup>
<col class="colWidth25" />
<col /></colgroup>
<thead>
<tr>
<th colspan="2">Flue gas O₂</th>
</tr>
</thead>
<tbody>
<tr>
<td class="table-bold">Measuring range</td>
<td>0 to 21 Vol.%</td>
</tr>
<tr>
<td class="table-bold">Accuracy</td>
<td>±0.2 Vol.%</td>
</tr>
<tr>
<td class="table-bold">Resolution</td>
<td>0.1 Vol.%</td>
</tr>
</tbody>
</table>
<table>
<colgroup>
<col class="colWidth25" />
<col /></colgroup>
<thead>
<tr>
<th colspan="2">Differential Pressure flue gas Draught &#8211; Piezoresistive</th>
</tr>
</thead>
<tbody>
<tr>
<td class="table-bold">Measuring range</td>
<td>-9.99 to +40 hPa</td>
</tr>
<tr>
<td class="table-bold">Accuracy</td>
<td>±0.005 hPa (+0 to +0.1 hPa)</p>
<p>±0.02 hPa (+0.1 to +3.00 hPa)</p>
<p>±1.5 % of mv (3.01 to +40 hPa)</td>
</tr>
<tr>
<td class="table-bold">Resolution</td>
<td>0.001 hPa (0 to 0.1 hPa)</p>
<p>0.01 hPa (Remaining Range)</td>
</tr>
</tbody>
</table>
<table>
<colgroup>
<col class="colWidth25" />
<col /></colgroup>
<thead>
<tr>
<th colspan="2">Flue gas degree of effectivity, Eta (calculated)</th>
</tr>
</thead>
<tbody>
<tr>
<td class="table-bold">Measuring range</td>
<td>0 to 120 %</td>
</tr>
<tr>
<td class="table-bold">Resolution</td>
<td>0.1 %</td>
</tr>
</tbody>
</table>
<table>
<colgroup>
<col class="colWidth25" />
<col /></colgroup>
<thead>
<tr>
<th colspan="2">Flue gas loss (calculated)</th>
</tr>
</thead>
<tbody>
<tr>
<td class="table-bold">Measuring range</td>
<td>0 to 99.9 %</td>
</tr>
<tr>
<td class="table-bold">Resolution</td>
<td>0.1 %</td>
</tr>
</tbody>
</table>
<table>
<colgroup>
<col class="colWidth25" />
<col /></colgroup>
<thead>
<tr>
<th colspan="2">Flue gas CO₂ calculation (calculated from O₂)</th>
</tr>
</thead>
<tbody>
<tr>
<td class="table-bold">Measuring range</td>
<td>Display range 0 to CO₂ max</td>
</tr>
<tr>
<td class="table-bold">Accuracy</td>
<td>±0.2 Vol.%</td>
</tr>
<tr>
<td class="table-bold">Resolution</td>
<td>0.1 Vol.%</td>
</tr>
</tbody>
</table>
<table>
<colgroup>
<col class="colWidth25" />
<col /></colgroup>
<thead>
<tr>
<th colspan="2">Flue gas CO (without H₂-compensation)</th>
</tr>
</thead>
<tbody>
<tr>
<td class="table-bold">Measuring range</td>
<td>0 to 4000 ppm</td>
</tr>
<tr>
<td class="table-bold">Accuracy</td>
<td>±20 ppm (0 to 400 ppm)</p>
<p>±5 % of mv (401 to 2000 ppm)</p>
<p>±10 % of mv (2001 to 4000 ppm)</td>
</tr>
<tr>
<td class="table-bold">Resolution</td>
<td>1 ppm</td>
</tr>
</tbody>
</table>
<table>
<colgroup>
<col class="colWidth25" />
<col /></colgroup>
<thead>
<tr>
<th colspan="2">Ambient CO</th>
</tr>
</thead>
<tbody>
<tr>
<td class="table-bold">Measuring range</td>
<td>0 to 2000 ppm</td>
</tr>
<tr>
<td class="table-bold">Accuracy</td>
<td>±10 ppm (0 to 100 ppm)</p>
<p>±10 % of mv (101 to 2000 ppm)</td>
</tr>
<tr>
<td class="table-bold">Resolution</td>
<td>1 ppm</td>
</tr>
</tbody>
</table>
<table>
<colgroup>
<col class="colWidth25" />
<col /></colgroup>
<thead>
<tr>
<th colspan="2">General technical data</th>
</tr>
</thead>
<tbody>
<tr>
<td class="table-bold">Operating humidity</td>
<td>15 to 90 %RH non-condensing</td>
</tr>
<tr>
<td class="table-bold">Dimensions</td>
<td>244 (including probe connection) x 98 x 59 LxWxH</td>
</tr>
<tr>
<td class="table-bold">Operating temperature</td>
<td>-5 to +45 °C</td>
</tr>
<tr>
<td class="table-bold">Protection class</td>
<td>IP40</td>
</tr>
<tr>
<td class="table-bold">Product colour</td>
<td>black/orange</td>
</tr>
<tr>
<td class="table-bold">Display type</td>
<td>5.0&#8243; touch display, HD 1280*720 pixels, IPS (160 k)</td>
</tr>
<tr>
<td class="table-bold">Power supply</td>
<td>Rechargeable battery, USB mains unit</td>
</tr>
<tr>
<td class="table-bold">Guarantee</td>
<td>Gas sensors (O₂, CO) 24 months; rechargeable battery: 12 months; Thermocouple 12 months</td>
</tr>
<tr>
<td class="table-bold">Authorizations</td>
<td>TÜV-tested according to 1st German Federal Immission Control Ordinance (BImSchV) EN 50379, Parts 1-3</td>
</tr>
<tr>
<td class="table-bold">Warranty conditions</td>
<td><a href="https://www.testo.com/guarantee">https://www.testo.com/guarantee</a></td>
</tr>
<tr>
<td class="table-bold">Memory</td>
<td>1,000,000 measuring values</td>
</tr>
<tr>
<td class="table-bold">Storage battery type</td>
<td>Lithium ion battery</td>
</tr>
<tr>
<td class="table-bold">Battery life</td>
<td>10 h</td>
</tr>
<tr>
<td class="table-bold">Storage temperature</td>
<td>-20 to +50 °C</td>
</tr>
<tr>
<td class="table-bold">Weight</td>
<td>approximately 800 g</td>
</tr>
<tr>
<td class="table-bold">Charging temperature</td>
<td>0 to +45 °C</td>
</tr>
</tbody>
</table>
<table>
<colgroup>
<col class="colWidth25" />
<col /></colgroup>
<thead>
<tr>
<th colspan="2">Differential Pressure 4 Pa measurement &#8211; Piezoresistive</th>
</tr>
</thead>
<tbody>
<tr>
<td class="table-bold">Measuring Range</td>
<td>-50 to +50 Pa</td>
</tr>
<tr>
<td class="table-bold">Accuracy</td>
<td>±0.3 Pa (&lt; 10 Pa)</p>
<p>±3 % of mv (Remaining Range)</td>
</tr>
<tr>
<td class="table-bold">Resolution</td>
<td>0.1 Pa</td>
</tr>
</tbody>
</table>
</article>
<p>The post <a href="https://rapid-tech.com.au/flue-gas-analyzer-o2-co-up-to-4000-ppm-testo-300-domestic-kit/">Flue gas analyzer (O2, CO up to 4,000 ppm) | Testo 300 Domestic Kit</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FLUKE CO-220 Carbon Monoxide Meter</title>
		<link>https://rapid-tech.com.au/fluke-co-220-carbon-monoxide-meter/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Tue, 11 May 2021 10:45:36 +0000</pubDate>
				<guid isPermaLink="false">https://fluke-test.com.au/?post_type=product&#038;p=1178</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-679" src="https://rapid-tech.com.au/wp-content/uploads/2020/07/Fluke-Logo-Small.png" alt="" width="200" height="67" /></p>
<h2>Fluke CO-220 Carbon Monoxide Meter</h2>
<h4 class="features-title">Features:</h4>
<div id="keyfeature_content" data-readmore="" aria-expanded="true">
<ul>
<li>Rugged case and electronics</li>
<li>Large LCD displays CO levels from 0 to 1000 ppm</li>
<li>Bright back-light allows easy screen viewing under dim lighting conditions</li>
<li>Beeper triggers with increasing frequency as CO levels rise</li>
<li>MAX Hold function stores and displays the maximum CO level</li>
<li>Automatic sensor zeroing and self-test sequence upon start-up</li>
<li>CO level beeper can be silenced if desired</li>
<li>Automatic power-off after 20 minutes extends battery life</li>
<li>Easy to replace battery</li>
<li>Replaceable sensor extends tool life</li>
<li>C50 soft carrying case, battery and instruction sheet</li>
<li>Stabilized electrochemical CO specific sensor</li>
<li>Typical two year sensor life; one year calibration cycle</li>
<li>Battery life typical 500 hours with alkaline battery</li>
<li>Updated sensor</li>
</ul>
<p>&#160;</p>
</div>
<p>The post <a href="https://rapid-tech.com.au/fluke-co-220-carbon-monoxide-meter/">FLUKE CO-220 Carbon Monoxide Meter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Fluke CO-220 Carbon Monoxide Meter</h3>
<div id="fluke-product-display-overview">
<div id="product-overview">
<div id="overview_content">
<h4><strong>Quickly and accurately measure CO levels with easy-to-use compact meter</strong></h4>
<p>The Fluke CO-220 Carbon Monoxide Meter makes it easy to take quick and accurate measurements of CO levels with a single compact instrument.</p>
<p>Featuring the newest generation of electrochemical sensors, the CO-220 responds very quickly to ambient changes in carbon monoxide concentration without the use of a pump.</p>
<p>The CO-220 is the perfect instrument for technicians and other professionals who need to measure CO levels within spaces such as industrial environments, commercial buildings, or residential dwellings where accumulation of combustion gas is possible.</p>
<h4>Specifications: Fluke CO-220 Carbon Monoxide Meter</h4>
<div id="fluke-product-display-specs">
<div id="product-specs">
<div id="specification_content">
<div class="clickability">
<table style="height: 92px;" width="489">
<tbody>
<tr>
<td colspan="2">General Specifications</td>
</tr>
<tr>
<td width="25%">Range</td>
<td>0 to 1000 ppm</td>
</tr>
<tr>
<td>Resolution</td>
<td>1 ppm</td>
</tr>
<tr>
<td>Accuracy</td>
<td>5%</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://rapid-tech.com.au/fluke-co-220-carbon-monoxide-meter/">FLUKE CO-220 Carbon Monoxide Meter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Testo 317-3 Carbon Monoxide Meter</title>
		<link>https://rapid-tech.com.au/testo-317-3-carbon-monoxide-meter/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Thu, 27 Feb 2020 01:23:56 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=14499</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-13413" src="https://rapid-tech.com.au/wp-content/uploads/2019/12/Testo-Be-Sure-Logo.jpg" alt="" width="207" height="90" />    <a target="_blank" href="https://mymeter.com.au/product/testo-317-3-carbon-monoxide-meter/" rel="noopener noreferrer"><img class="alignnone wp-image-5427 size-thumbnail" src="https://rapid-tech.com.au/wp-content/uploads/2017/08/Buy-Now-small-150x65.jpg" alt="" width="150" height="65" /></a></p>
<p><span style="font-size: 120%;"><em><strong>Carbon monoxide is a silent killer. </strong></em></span></p>
<p>The compact Testo 317-3 CO meter is designed to provide you with a quick and reliable means of testing ambient air for carbon monoxide.</p>
<h3>Features:</h3>
<ul class="list-elements">
<li>Instant Start up: no zeroing phase</li>
<li>3-year warranty on CO sensor</li>
<li>Alarm with adjustable thresholds</li>
<li>Carry case with belt clip and hand strap</li>
</ul>
<h3><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" />    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/02/Testo-317-3-Users-Manual.pdf" rel="noopener noreferrer">Testo 317-3 Users Manual</a></span></h3>
<p><iframe src="https://www.youtube.com/embed/xUqVmvRSgIw" width="721" height="541" frameborder="0" allowfullscreen="allowfullscreen"></iframe></p>
<p>The post <a href="https://rapid-tech.com.au/testo-317-3-carbon-monoxide-meter/">Testo 317-3 Carbon Monoxide Meter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Testo 317-3 Carbon Monoxide Meter</h2>
<p>Carbon monoxide is a particularly dangerous gas. It is colorless, it is odorless and above all it is lethal. That’s why it is so important that CO checks are carried out by the book when a gas heating or boiler is being serviced or installed. This not only ensures that the heating or boiler is working properly, it also helps to prevent tragic accidents that occur as a result of carbon monoxide poisoning.</p>
<h3>The Testo 317-3 CO meter. For measuring carbon monoxide in the surrounding air</h3>
<p>A few seconds. That’s all it takes. That’s all it takes to be on the safe side and test the surrounding air for carbon monoxide. The testo 317-3 CO tester measures the concentration of carbon monoxide in ambient air and presents the readings on an easy-to-read display. The CO meter has both a visual and an audible alarm which are triggered when a threshold is crossed.</p>
<p>The CO meter comes with a carry case and a belt clip to ensure that you always have your meter on you and a strap which can be wrapped loosely around the wrist to prevent the meter from falling onto the floor.</p>
<h2 class="s4 title">CO measurement in the heated environment</h2>
<p class="s4 title"><div class="row"  id="row-224257254">

	<div id="col-25774698" class="col medium-2/3 large-8"  >
				<div class="col-inner"  >
			
			
<p>Carbon monoxide (CO) is a colourless, odourless and taste-free gas, but also poisonous. Its sources include the incomplete combustion of substances containing carbon (oil, gas and solid fuels, etc.).</p>
<p>If CO manages to get into the bloodstream through the lungs, it combines with haemoglobin thus preventing oxygen from being transported in the blood; this in turn will result in death through suffocation.</p>
<p>This is why it is necessary to regularly check CO emissions at the combustion points of heating systems and also in the surrounding areas.</p>
		</div>
					</div>

	

	<div id="col-832000677" class="col medium-1/3 large-4"  >
				<div class="col-inner"  >
			
			
<p><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/02/Testo-713-in-use.jpg" rel="noopener noreferrer"><img loading="lazy" decoding="async" class="aligncenter wp-image-14500 size-medium" src="https://rapid-tech.com.au/wp-content/uploads/2020/02/Testo-713-in-use-230x300.jpg" alt="" width="230" height="300" srcset="https://rapid-tech.com.au/wp-content/uploads/2020/02/Testo-713-in-use-230x300.jpg 230w, https://rapid-tech.com.au/wp-content/uploads/2020/02/Testo-713-in-use-300x391.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2020/02/Testo-713-in-use.jpg 454w" sizes="auto, (max-width: 230px) 100vw, 230px" /></a></p>
		</div>
					</div>

	
</div>
<p><strong>PLEASE NOTE:</strong> The Testo 317-3 is suitable to check Co in ambient air, Its however not suitable for measuring CO in discharged airstream.</p>
<div class="is-divider divider clearfix" style="max-width:100%;"></div>
<h3>Testo 317-3 Specifications:</h3>
<table style="height: 224px;" width="485">
<thead>
<tr>
<th colspan="2">Ambient CO</th>
</tr>
</thead>
<tbody>
<tr>
<td class="table-bold">Measuring range</td>
<td>0 to +1999 ppm</td>
</tr>
<tr>
<td class="table-bold">Accuracy</td>
<td>±3 ppm (0 to +29 ppm)</p>
<p>±10 % (+30 to +1999 ppm)</td>
</tr>
<tr>
<td class="table-bold">Resolution</td>
<td>1 ppm</td>
</tr>
</tbody>
</table>
<table style="height: 248px;" width="486">
<colgroup>
<col class="colWidth25" />
<col /></colgroup>
<thead>
<tr>
<th colspan="2">General technical data</th>
</tr>
</thead>
<tbody>
<tr>
<td class="table-bold">Operating temperature</td>
<td>-5 to +45 °C</td>
</tr>
<tr>
<td class="table-bold">Battery type</td>
<td>2 AAA micro batteries</td>
</tr>
<tr>
<td class="table-bold">Battery life</td>
<td>150 h (with beeper switched off)</td>
</tr>
<tr>
<td class="table-bold">Storage temperature</td>
<td>-20 to +45 °C</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>The post <a href="https://rapid-tech.com.au/testo-317-3-carbon-monoxide-meter/">Testo 317-3 Carbon Monoxide Meter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>CEM DT-9881M Air Particle Counter + Gas Detector</title>
		<link>https://rapid-tech.com.au/cem-dt-9881m-air-particle-counter-gas-detector/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 07 Jan 2020 09:09:16 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=13678</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-9810" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/CEM-Logo-medium.jpg" alt="" width="150" height="66" /></p>
<p>The CEM DT-9881M Air Particle Counter with 2.8”color TFT LCD display with the ability to measure Suspended Particle Mass Concentration.</p>
<p>With a microSD memory card you can capture images (JPEG) or video (3GP) for viewing on your PC, providing  fast, easy and accurate readings for particle counter, plus <strong>S</strong><strong style="font-size: 14.4px;">uspended Particle Concentration in the air of the weight method (PM2.5/PM10),</strong> <strong>GAS Formaldehyde (HCHO) &#38; Carbon Monoxide (CO) detectors,</strong> air temperature &#38; relative humidity.</p>
<p>It is the ideal instrument for air quality and environmental safety surveys.</p>
<h3><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" />    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/01/CEM-DT-9881M-Datasheet.pdf" rel="noopener noreferrer">CEM DT-9881M Datasheet</a></span></h3>
<p>The post <a href="https://rapid-tech.com.au/cem-dt-9881m-air-particle-counter-gas-detector/">CEM DT-9881M Air Particle Counter + Gas Detector</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span style="font-size: 100%;">CEM DT-9881M Air Particle Counter + Gas Detector provides fast,easy and accurate readings for particle count, It can measure <strong>Suspended Particle Concentration, </strong><strong>GAS Formaldehyde (HCHO) &amp; Carbon Monoxide (CO) </strong>detectection, air temperature &amp; relative humidity &amp;,most surface temperature measurements.</span></p>
<p><span style="font-size: 100%;">The CEM DT-9881M Air Particle Counter has many functions. With it is possible to determine the number of particles in the size of 0.3, 2.5 and 10 µm. In addition to measuring the particles, the fine dust it can also measure the PM 2.5 and PM 10 mass concentration. The mass concentration of the fine dust determines the weight of the particles in one cubic metre. </span></p>
<p><span style="font-size: 100%;">In addition the CEM DT-9881M can also determine the formaldehyde content in ppm. During this HCHO measurement, the temperature, the ambient humidity and the dew point are determined and displayed by it.  As a further important feature it can all store data and it is therefore possible  to evaluate all measured values ​​after a measurement.</span></p>
<p><span style="font-size: 100%;">It is the ideal instrument for environmental safety and energy saving surveys.</span></p>
<h4><strong>CEM DT-9881M Air Particle Counter + Gas Detector Features:</strong></h4>
<ul>
<li><strong>Measures suspended particle concentration in the air of the weight method (PM2.5/PM10)</strong></li>
<li>2.8″ TFT 320×240 pixels Color LCD display</li>
<li>Images(JPEG) &amp; Video(3GP)</li>
<li><strong>Simultaneously measure and display 6 channel of particle sizes, measure particle size down to 0.3 </strong><strong>μm</strong></li>
<li>IR temperature measure &amp; Laser targeting</li>
<li><strong>GAS Formaldehyde (HCHO) &amp; Carbon Monoxide (CO) detectors</strong></li>
<li><strong>Air temperature and humidity, Dew point &amp; Wet bulb temperature</strong></li>
<li>Max, Min, DIF, AVG record, Date/time setup controls, High and low alarm</li>
<li>Adjustable emissivity &amp; Trigger lock</li>
<li>MicroSD (MAX. use 8GB) memory card, USB interface</li>
<li>Auto Power Off</li>
<li>Selectable sample time, count data, programmable delay</li>
<li>Store 5000 records of date, time, counts, relative humidity, temperature, sample volumes, alarms and location label</li>
<li>Language selection English, Chinese, French, German, Spanish</li>
</ul>
<h4><strong>CEM DT-9881M Air Particle Counter + Gas Detector Specifications:</strong></h4>
<table width="567">
<tbody>
<tr>
<td width="227">Channel</td>
<td width="340">0.3, 0.5, 1.0,2.5, 5.0, 10μm</td>
</tr>
<tr>
<td width="227">Flow Rate</td>
<td width="340">0.1ft 3 (2.83L/min) controlled by internal pump</td>
</tr>
<tr>
<td width="227">Count Modes</td>
<td width="340">Totalize, Concentration, Audio</td>
</tr>
<tr>
<td width="227">Coincidence Loss</td>
<td width="340">5%, 2,000,000 particles per ft³</td>
</tr>
<tr>
<td width="227">Mass Concentration Channel</td>
<td width="340">PM2.5 ：0~500ug/m³ ；PM10：0~500ug/m³</td>
</tr>
<tr>
<td colspan="2" width="567"><strong>Air Temperature Measure</strong></td>
</tr>
<tr>
<td rowspan="2" width="227">Air Temp Range</td>
<td width="340">0 to 50ºC/32 to 122ºF;</td>
</tr>
<tr>
<td width="340">Basic Accuracy: ±0.5ºC/1ºF</td>
</tr>
<tr>
<td rowspan="2" width="227">Humidity Range</td>
<td width="340">0 to 100%RH;</td>
</tr>
<tr>
<td width="340">Basic Accuracy: ±2.5%RH (20%~80%RH)</td>
</tr>
<tr>
<td width="227">Dew Point Temp. Range</td>
<td width="340">-30~100ºC/ -22~199ºF</td>
</tr>
<tr>
<td width="227">Wet Bulb Temp. Range</td>
<td width="340">0~80ºC/ 32~176ºF</td>
</tr>
<tr>
<td colspan="2" width="567"><strong>GAS Detectors</strong></td>
</tr>
<tr>
<td width="227">HCHO (methanal) Range</td>
<td width="340">0.01~5.00ppm; Basic Accuracy: ±5%F.S</td>
</tr>
<tr>
<td width="227">CO (carbon monoxide) Range</td>
<td width="340">0~1000ppm; Basic Accuracy:±5%F.S</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/cem-dt-9881m-air-particle-counter-gas-detector/">CEM DT-9881M Air Particle Counter + Gas Detector</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Testo 300 Flue Gas Analyzer (O2, CO up to 4,000 ppm)</title>
		<link>https://rapid-tech.com.au/testo-300-flue-gas-analyzer-o2-co-up-to-4000-ppm/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Wed, 11 Dec 2019 04:27:41 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=13470</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-13413" src="https://rapid-tech.com.au/wp-content/uploads/2019/12/Testo-Be-Sure-Logo.jpg" alt="" width="207" height="90" /></p>
<p>The Testo 300 flue gas analyzer is ideal for the most important measurements involving heating systems. It combines decades of experience in measuring technology with contemporary smart-touch operation, robust construction and e-mailing of reports.</p>
<p>The Testo 300 enables easy measurement of flue gas, draught, pressure, ambient CO and differential temperature.</p>
<ul class="list-elements">
<li>Intuitive measurement menus and the fast-response Smart-Touch display ensure easy operation – as on your smartphone</li>
<li>Including O<sub>2</sub> and CO sensor up to 4,000 ppm</li>
<li>Large 5-inch HD display – see all the system's measuring values at a glance</li>
<li>Creation of documentation directly on site and e-mailing of reports</li>
</ul>
<h3><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" />    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2019/12/Testo-300-Datasheet.pdf" rel="noopener noreferrer">Testo 300 Datasheet</a></span></h3>
<h3><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" />    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2019/12/Testo-300-User-Manual.pdf" rel="noopener noreferrer">Testo 300 User Manual</a></span></h3>
<p>The post <a href="https://rapid-tech.com.au/testo-300-flue-gas-analyzer-o2-co-up-to-4000-ppm/">Testo 300 Flue Gas Analyzer (O2, CO up to 4,000 ppm)</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Testo 300 Flue gas analyzer is truly a smart flue gas measurement instrument for use on heating systems. High-quality sensors, intuitive operation with smart-touch technology and smart features, such as efficient documentation and e-mailing of reports, The Testo 300 will make your day-to-day work easier.</p>
<h3>Testo 300 flue gas analyzer with smart-touch operation</h3>
<h4><strong>Impressive measuring technology and quality</strong></h4>
<ul>
<li>O<sub>2</sub> sensor and CO sensor up to 4,000 ppm</li>
<li>Longer sensor service life thanks to automatic sensor protection</li>
<li>TÜV-tested according to first German Federal Immission Control Ordinance (BImSchV) and EN 50379, Parts 1-3</li>
<li>Integrated fine pressure</li>
<li>Versatile probes and fast probe changes: take advantage of quick-change probes and the multi-functional handle for attaching a variety of probe shafts (each available to order separately). You can for instance use longer probe shafts for flue gas pipes with larger diameters or flexible probes for difficult-to-access measuring points</li>
<li>Optionally available probes and accessories for further measuring tasks, such as gas flow pressure measurement, gas pipe testing, differential temperature measurement and ambient CO measurement</li>
</ul>
<h4> <strong>Smart, intuitive, efficient: easy operation in day-to-day work</strong></h4>
<ul>
<li>Smart-touch display for intuitive operation of the flue gas analyzer: the display responds without delay – just as easy as on your smartphone</li>
<li>Get the measurement result faster: clearly structured measurement menus for all relevant measurements</li>
<li>Create documentation (including measuring value, measuring location, customer data) easily on site</li>
<li>Save PDF measurement reports directly in the instrument and always have them available</li>
<li>Signature function: your customer can sign measurement reports directly on the instrument</li>
<li>E-mail measurement reports directly to the office or to customers via WLAN (hotspot)</li>
<li>Large 5-inch HD display – enables you to see all the system&#8217;s parameters immediately</li>
<li>Testo interface function for direct data transfer of measuring values to industry/customer-specific software*</li>
<li>Ready to use straight away: in standby mode, the testo 300 is ready to measure at the touch of a button. Use it straight away with the next customer – because you no longer need to wait for the end of the zeroing phase</li>
<li>Integrated Bluetooth<sup>®</sup> interface: immediate printout of the measuring values on site with the appropriate printer</li>
</ul>
<p>*Note: the manufacturer has to integrate an interface into the industry software to use the function</p>
<h4> <strong>Other advantages</strong></h4>
<ul>
<li>10-hour rechargeable battery life: an average measurement period of 2 hours means the flue gas analyzer is capable of being used for one week</li>
<li>Integrated, extra-strong magnets for easy fixing during the measuring process</li>
</ul>
<div class="is-divider divider clearfix" style="max-width:100%;"></div>
<h3 class="s4 title">Flue gas measurement on heating systems</h3>
<div class="row"  id="row-559137469">

	<div id="col-855975399" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<p><strong>Ideal for measurements involving heating systems:</strong></p>
<ul>
<li>high-quality sensors, smart-touch operation, clearly structured measurement menus, creation of documentation on site, e-mailing of reports, large HD display, robust housing</li>
</ul>
<p><strong>Further areas of application:</strong></p>
<ul>
<li>gas flow pressure measurement*, gas pipe test*, differential temperature measurement (flow and return temperature on heating systems)*, ambient CO measurement*, flue draught measurement on heating systems*</li>
</ul>
		</div>
					</div>

	

	<div id="col-1041924550" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<p>&nbsp;</p>
<p><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-13471" src="https://rapid-tech.com.au/wp-content/uploads/2019/12/Testo-300-Fluegas-Measurement-300x217.jpg" alt="" width="300" height="217" srcset="https://rapid-tech.com.au/wp-content/uploads/2019/12/Testo-300-Fluegas-Measurement-300x217.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2019/12/Testo-300-Fluegas-Measurement-600x435.jpg 600w, https://rapid-tech.com.au/wp-content/uploads/2019/12/Testo-300-Fluegas-Measurement-768x557.jpg 768w, https://rapid-tech.com.au/wp-content/uploads/2019/12/Testo-300-Fluegas-Measurement.jpg 999w" sizes="auto, (max-width: 300px) 100vw, 300px" /><br />
		</div>
					</div>

	
</div>
<p><em>* Please note: additional probes or accessories are required for these measurements and have to be ordered separately.</em></p>
<div class="is-divider divider clearfix" style="max-width:100%;"></div>
<h2>Models, Probes and Accessories</h2>
<p>Refer to Testo 300 Datasheet for information on available models, probes and accessories.</p>
<div class="is-divider divider clearfix" style="max-width:100%;"></div>
<h2>Testo 300 Flue gas analyzer Specification</h2>
<table>
<colgroup>
<col class="colWidth25" />
<col /></colgroup>
<thead>
<tr>
<th colspan="2">Temperature &#8211; TC Type K (NiCr-Ni)</th>
</tr>
</thead>
<tbody>
<tr>
<td class="table-bold">Measuring range</td>
<td>-40 to +1200 °C</td>
</tr>
<tr>
<td class="table-bold">Accuracy</td>
<td>±0.5 °C (0.0 to +100.0 °C)</p>
<p>±0.5 % of mv (Remaining Range)</td>
</tr>
<tr>
<td class="table-bold">Resolution</td>
<td>0.1 °C (-40 to +999.9 °C)</p>
<p>1 °C (Remaining Range)</td>
</tr>
</tbody>
</table>
<table>
<colgroup>
<col class="colWidth25" />
<col /></colgroup>
<thead>
<tr>
<th colspan="2">Differential Pressure &#8211; Piezoresistive</th>
</tr>
</thead>
<tbody>
<tr>
<td class="table-bold">Measuring range</td>
<td>-100 to +200 hPa</td>
</tr>
<tr>
<td class="table-bold">Accuracy</td>
<td>±0.5 hPa (0 to +50.0 hPa)</p>
<p>±1 % of mv (+50.1 to +100.0 hPa)</p>
<p>±1.5 % of mv (+100.1 to +200 hPa)</td>
</tr>
<tr>
<td class="table-bold">Resolution</td>
<td>0.01 hPa</td>
</tr>
</tbody>
</table>
<table>
<colgroup>
<col class="colWidth25" />
<col /></colgroup>
<thead>
<tr>
<th colspan="2">Flue gas O₂</th>
</tr>
</thead>
<tbody>
<tr>
<td class="table-bold">Measuring range</td>
<td>0 to 21 Vol.%</td>
</tr>
<tr>
<td class="table-bold">Accuracy</td>
<td>±0.2 Vol.%</td>
</tr>
<tr>
<td class="table-bold">Resolution</td>
<td>0.1 Vol.%</td>
</tr>
</tbody>
</table>
<table>
<colgroup>
<col class="colWidth25" />
<col /></colgroup>
<thead>
<tr>
<th colspan="2">Differential Pressure flue gas Draught &#8211; Piezoresistive</th>
</tr>
</thead>
<tbody>
<tr>
<td class="table-bold">Measuring range</td>
<td>-9.99 to +40 hPa</td>
</tr>
<tr>
<td class="table-bold">Accuracy</td>
<td>±0.005 hPa (+0 to +0.1 hPa)</p>
<p>±0.02 hPa (+0.1 to +3.00 hPa)</p>
<p>±1.5 % of mv (3.01 to +40 hPa)</td>
</tr>
<tr>
<td class="table-bold">Resolution</td>
<td>0.001 hPa (0 to 0.1 hPa)</p>
<p>0.01 hPa (Remaining Range)</td>
</tr>
</tbody>
</table>
<table>
<colgroup>
<col class="colWidth25" />
<col /></colgroup>
<thead>
<tr>
<th colspan="2">Flue gas degree of effectivity, Eta (calculated)</th>
</tr>
</thead>
<tbody>
<tr>
<td class="table-bold">Measuring range</td>
<td>0 to 120 %</td>
</tr>
<tr>
<td class="table-bold">Resolution</td>
<td>0.1 %</td>
</tr>
</tbody>
</table>
<table>
<colgroup>
<col class="colWidth25" />
<col /></colgroup>
<thead>
<tr>
<th colspan="2">Flue gas loss (calculated)</th>
</tr>
</thead>
<tbody>
<tr>
<td class="table-bold">Measuring range</td>
<td>0 to 99.9 %</td>
</tr>
<tr>
<td class="table-bold">Resolution</td>
<td>0.1 %</td>
</tr>
</tbody>
</table>
<table>
<colgroup>
<col class="colWidth25" />
<col /></colgroup>
<thead>
<tr>
<th colspan="2">Flue gas CO₂ calculation (calculated from O₂)</th>
</tr>
</thead>
<tbody>
<tr>
<td class="table-bold">Measuring range</td>
<td>Display range 0 to CO₂ max</td>
</tr>
<tr>
<td class="table-bold">Accuracy</td>
<td>±0.2 Vol.%</td>
</tr>
<tr>
<td class="table-bold">Resolution</td>
<td>0.1 Vol.%</td>
</tr>
</tbody>
</table>
<table>
<colgroup>
<col class="colWidth25" />
<col /></colgroup>
<thead>
<tr>
<th colspan="2">Flue gas CO (without H₂-compensation)</th>
</tr>
</thead>
<tbody>
<tr>
<td class="table-bold">Measuring range</td>
<td>0 to 4000 ppm</td>
</tr>
<tr>
<td class="table-bold">Accuracy</td>
<td>±20 ppm (0 to 400 ppm)</p>
<p>±5 % of mv (401 to 2000 ppm)</p>
<p>±10 % of mv (2001 to 4000 ppm)</td>
</tr>
<tr>
<td class="table-bold">Resolution</td>
<td>1 ppm</td>
</tr>
</tbody>
</table>
<table>
<colgroup>
<col class="colWidth25" />
<col /></colgroup>
<thead>
<tr>
<th colspan="2">Ambient CO</th>
</tr>
</thead>
<tbody>
<tr>
<td class="table-bold">Measuring range</td>
<td>0 to 2000 ppm</td>
</tr>
<tr>
<td class="table-bold">Accuracy</td>
<td>±10 ppm (0 to 100 ppm)</p>
<p>±10 % of mv (101 to 2000 ppm)</td>
</tr>
<tr>
<td class="table-bold">Resolution</td>
<td>1 ppm</td>
</tr>
</tbody>
</table>
<table>
<colgroup>
<col class="colWidth25" />
<col /></colgroup>
<thead>
<tr>
<th colspan="2">General technical data</th>
</tr>
</thead>
<tbody>
<tr>
<td class="table-bold">Operating humidity</td>
<td>15 to 90 %RH non-condensing</td>
</tr>
<tr>
<td class="table-bold">Dimensions</td>
<td>244 (including probe connection) x 98 x 59 LxWxH</td>
</tr>
<tr>
<td class="table-bold">Operating temperature</td>
<td>-5 to +45 °C</td>
</tr>
<tr>
<td class="table-bold">Protection class</td>
<td>IP40</td>
</tr>
<tr>
<td class="table-bold">Product colour</td>
<td>black/orange</td>
</tr>
<tr>
<td class="table-bold">Display type</td>
<td>5.0&#8243; touch display, HD 1280*720 pixels, IPS (160 k)</td>
</tr>
<tr>
<td class="table-bold">Power supply</td>
<td>Rechargeable battery, USB mains unit</td>
</tr>
<tr>
<td class="table-bold">Guarantee</td>
<td>Gas sensors (O₂, CO) 24 months; rechargeable battery: 12 months; Thermocouple 12 months</td>
</tr>
<tr>
<td class="table-bold">Authorizations</td>
<td>TÜV-tested according to 1st German Federal Immission Control Ordinance (BImSchV) EN 50379, Parts 1-3</td>
</tr>
<tr>
<td class="table-bold">Warranty conditions</td>
<td><a href="https://www.testo.com/guarantee">https://www.testo.com/guarantee</a></td>
</tr>
<tr>
<td class="table-bold">Memory</td>
<td>1,000,000 measuring values</td>
</tr>
<tr>
<td class="table-bold">Storage battery type</td>
<td>Lithium ion battery</td>
</tr>
<tr>
<td class="table-bold">Battery life</td>
<td>10 h</td>
</tr>
<tr>
<td class="table-bold">Storage temperature</td>
<td>-20 to +50 °C</td>
</tr>
<tr>
<td class="table-bold">Weight</td>
<td>approximately 800 g</td>
</tr>
<tr>
<td class="table-bold">Charging temperature</td>
<td>0 to +45 °C</td>
</tr>
</tbody>
</table>
<table>
<colgroup>
<col class="colWidth25" />
<col /></colgroup>
<thead>
<tr>
<th colspan="2">Differential Pressure 4 Pa measurement &#8211; Piezoresistive</th>
</tr>
</thead>
<tbody>
<tr>
<td class="table-bold">Measuring Range</td>
<td>-50 to +50 Pa</td>
</tr>
<tr>
<td class="table-bold">Accuracy</td>
<td>±0.3 Pa (&lt; 10 Pa)</p>
<p>±3 % of mv (Remaining Range)</td>
</tr>
<tr>
<td class="table-bold">Resolution</td>
<td>0.1 Pa</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/testo-300-flue-gas-analyzer-o2-co-up-to-4000-ppm/">Testo 300 Flue Gas Analyzer (O2, CO up to 4,000 ppm)</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Testo 310 Basic Flue Gas Analyser</title>
		<link>https://rapid-tech.com.au/testo-310-basic-flue-gas-analyser/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sat, 07 Dec 2019 07:50:58 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=13425</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-13413" src="https://rapid-tech.com.au/wp-content/uploads/2019/12/Testo-Be-Sure-Logo.jpg" alt="" width="207" height="90" />    <a target="_blank" href="https://mymeter.com.au/product/testo-310-flue-gas-analyzer/" rel="noopener noreferrer"><img class="alignnone wp-image-5427 size-thumbnail" src="https://rapid-tech.com.au/wp-content/uploads/2017/08/Buy-Now-small-150x65.jpg" alt="" width="150" height="65" /></a></p>
<p><strong>The Testo 310 basic flue gas analyser</strong> sets a new standard in affordable flue gas analysis with its rugged housing, simple design and advanced sensor technology. With five different fuels to select from, it provides the flexibility you need for your applications like checking furnace efficiency, boiler tuning, and water heater checks.</p>
<h4><strong>Features:</strong></h4>
<ul class="list-elements">
<li>Integrated measurement menus: Flue gas, draught, ambient CO &#38; pressure</li>
<li>Bright backlit 2 line display and icons for easy viewing</li>
<li>Battery life up to 10 hours</li>
<li>2 year warranty</li>
</ul>
<h4><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" />    <span style="text-decoration: underline;"><span style="font-size: 110%;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2019/12/Testo-310-Datasheet.pdf" rel="noopener noreferrer">Testo 310 Datasheet</a></span></span></h4>
<h4><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" />    <span style="text-decoration: underline;"><span style="font-size: 110%;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2019/12/Testo-310-Users-Manual.pdf" rel="noopener noreferrer">Testo 310 Users Manual</a></span></span></h4>
<p><iframe src="https://www.youtube.com/embed/6NgdlOpsLPk?list=PLjMJHBkSDaw4KOwUOME0WW_VaOyjxisz_" width="962" height="541" frameborder="0" allowfullscreen="allowfullscreen"></iframe></p>
<p>The post <a href="https://rapid-tech.com.au/testo-310-basic-flue-gas-analyser/">Testo 310 Basic Flue Gas Analyser</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>The Testo 310 basic flue gas analyzer. For reliable heating system checks</h3>
<p>The Testo 310 Basic Flue Gas Analyser is a fully featured residential combustion analyzer that provides exceptional value and complete capabilities in combustion testing and furnace efficiency. With its capability to perform both basic, or more complex flue gas analysis, maintenance or safety checks, or confirm furnace efficiency, the fully featured Testo 310 combustion analyzer delivers more combustion parameters.</p>
<p>The stainless steel probe and cone-stop is perfect for residential, and boiler applications. The 310 can be used for accurate heating adjustments, so you can get it right the first time &#8211; every time.</p>
<p>With <strong>five different fuels</strong> to select from (Natural Gas, Propane, Fuel Oil , Biomass 5%, Wood 20%), it provides the flexibility you need for your tuning opportunities. With an optional printer kit available, you are able to keep records of all readings taken.</p>
<h2>Testo 310 Applications:</h2>
<h3>Draught measurement in the flue gas duct</h3>
<p>Draught measurement is actually a differential pressure measurement. This differential pressure occurs between two sub-areas as a result of a difference in temperature. This is turn generates a flow to compensate. In the case of flue gas systems, the difference in pressure is an indicator of the “chimney flue draught”. This is measured between the flue gas and ambient air at the measurement orifice at the core of the flue gas flow.</p>
<p>To ensure the flue gases are safely transported through the chimney there must be a differential pressure (chimney flue draught) for boiler systems that work with low pressure.</p>
<p>If the draught is permanently too high, the average flue gas temperature increases and therefore flue gas loss. The level of efficiency drops.</p>
<p>If the draught is permanently too low, oxygen may be lacking during combustion, resulting in soot and carbon monoxide. This will also cause a drop in the level of efficiency.</p>
<h3>Ambient CO measurement in the heated environment</h3>
<p>Carbon monoxide (CO) is a colourless, odourless and taste-free gas, but also poisonous. It is produced during the incomplete combustion of substances containing carbon (oil, gas, and solid fuels, etc.). If CO manages to get into the bloodstream through the lungs, it combines with haemoglobin thus preventing oxygen from being transported in the blood; this in turn will result in death through suffocation. This is why it is necessary to regularly check CO emissions at the combustion points of heating systems, and places often frequented by people (in our case, where the combustion systems for hot water generation are), and in the surrounding areas.</p>
<h3>Measuring the flue gas parameters of the burner (CO, O2, and temperature, etc.)</h3>
<p>The flue gas measurement for a heating system helps to establish the pollutants released with the flue gas (e.g. carbon monoxide CO) and the heating energy lost with the warm flue gas. In some countries, flue gas measurement is a legal requirement. It primarily has two objectives:</p>
<p>1. Ensuring the atmosphere is contaminated as little as possible by pollutants; and</p>
<p>2. energy is used as efficiently as possible.</p>
<p>Stipulated pollutant quantities per flue gas volume and energy losses must never be exceeded.</p>
<p>Measurement in terms of results required by law takes place during standard operation (every performance primarily using the appliance). Using a Lambda probe (single hole or multi-hole probe), the measurement is taken at the centre of flow in the connecting pipe (in the centre of the pipe cross-section, not at the edge) between the boiler and chimney/flue. The measured values are recorded by the flue gas analyzer and can be logged either for print out or transfer to a PC at a later stage.</p>
<p>Measurement is taken by the installer at commissioning, and if necessary four weeks later by the flue gas inspector/chimney sweep, and then at regular intervals by the authorised service engineer.</p>
<h3>Measuring pressure on burners (nozzle pressure, gas flow pressure, etc.)</h3>
<p>Standard readings taken during services of domestic heating systems include checking the gas pressure on the burners. This involves measuring the gas flow pressure and gas resting pressure. The flow pressure, also called supplied pressure, refers to the gas pressure of the flowing gas and resting pressure of the static gas. If the flow pressure for gas boilers is slightly outside the 18 to 25 mbar range, adjustments must not be made and the boiler must not be put into operation. If put into operation nonetheless, the burner will not be able to function properly, and explosions will occur when setting the flame and ultimately malfunctions; the burner will therefore fail and the heating system will shut down.</p>
<div class="is-divider divider clearfix" style="max-width:100%;"></div>
<h2>Testo 310 Specifications:</h2>
<table width="651">
<tbody>
<tr style="font-style: inherit; font-weight: inherit;">
<td colspan="2" width="651"><strong>Temperature &#8211; TC Type K (NiCr-Ni)</strong></td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Measuring range</td>
<td style="font-style: inherit;" width="276">-20 to +100 °C</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Accuracy</td>
<td style="font-style: inherit;" width="276">±1 °C</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Resolution</td>
<td style="font-style: inherit;" width="276">0.1 °C</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Reaction time</td>
<td style="font-style: inherit;" width="276">&lt; 50 s</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td width="375"><strong>Temperature (ambient temperature)</strong></td>
<td></td>
</tr>
<tr>
<td colspan="2" width="651">Temperature &#8211; TC Type J (Fe-CuNi)</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Measuring range</td>
<td style="font-style: inherit;" width="276">0 to +400 °C</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" rowspan="2" width="375">Accuracy</td>
<td style="font-style: inherit;" width="276">±1 °C (0 to +100 °C)</td>
</tr>
<tr>
<td width="276">±1.5 % of mv (&gt; 100 °C)</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Resolution</td>
<td style="font-style: inherit;" width="276">0.1 °C</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Reaction time</td>
<td style="font-style: inherit;" width="276">&lt; 50 s</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td width="375"><strong>Temperature (flue gas)</strong></td>
<td></td>
</tr>
<tr>
<td colspan="2" width="651">Flue gas O₂</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Measuring range</td>
<td style="font-style: inherit;" width="276">0 to 21 Vol.%</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Accuracy</td>
<td style="font-style: inherit;" width="276">±0.2 Vol.%</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Resolution</td>
<td style="font-style: inherit;" width="276">0.1 Vol.%</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Reaction time t₉₀</td>
<td style="font-style: inherit;" width="276">30 s</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2" width="651"><strong>Flue gas Draught</strong></td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Measuring range</td>
<td style="font-style: inherit;" width="276">-20 to +20 hPa</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" rowspan="2" width="375">Accuracy</td>
<td style="font-style: inherit;" width="276">±0.03 hPa (-3.00 to +3.00 hPa)</td>
</tr>
<tr>
<td width="276">±1.5 % of mv (Remaining Range)</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Resolution</td>
<td style="font-style: inherit;" width="276">0.01 hPa</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2" width="651"><strong>Flue gas degree of effectivity, Eta (calculated)</strong></td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Measuring range</td>
<td style="font-style: inherit;" width="276">0 to 120 %</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Resolution</td>
<td style="font-style: inherit;" width="276">0.10%</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2" width="651"><strong>Flue gas loss (calculated)</strong></td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Measuring range</td>
<td style="font-style: inherit;" width="276">0 to 99.9 %</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Resolution</td>
<td style="font-style: inherit;" width="276">0.10%</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2" width="651"><strong>Flue gas CO₂ calculation (calculated from O₂)</strong></td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Measuring range</td>
<td style="font-style: inherit;" width="276">0 to CO₂ max (Display range)</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Accuracy</td>
<td style="font-style: inherit;" width="276">±0.2 Vol.%</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Resolution</td>
<td style="font-style: inherit;" width="276">0.1 Vol.%</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Reaction time t₉₀</td>
<td style="font-style: inherit;" width="276">&lt; 40 s</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2" width="651"><strong>Pressure measurement</strong></td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Measuring range</td>
<td style="font-style: inherit;" width="276">-40 to +40 hPa</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Accuracy</td>
<td style="font-style: inherit;" width="276">±0.5 hPa</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Resolution</td>
<td style="font-style: inherit;" width="276">0.1 hPa</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2" width="651"><strong>Flue gas CO (without H₂-compensation)</strong></td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Measuring range</td>
<td style="font-style: inherit;" width="276">0 to 4000 ppm</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" rowspan="3" width="375">Accuracy</td>
<td style="font-style: inherit;" width="276">±20 ppm (0 to 400 ppm)</td>
</tr>
<tr>
<td width="276">±5 % of mv (401 to 2000 ppm)</td>
</tr>
<tr>
<td width="276">±10 % of mv (2001 to 4000 ppm)</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Resolution</td>
<td style="font-style: inherit;" width="276">1 ppm</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Reaction time t₉₀</td>
<td style="font-style: inherit;" width="276">60 s</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2" width="651"><strong>Ambient CO</strong></td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Measuring range</td>
<td style="font-style: inherit;" width="276">0 to 4000 ppm</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" rowspan="3" width="375">Accuracy</td>
<td style="font-style: inherit;" width="276">±20 ppm (0 to 400 ppm)</td>
</tr>
<tr>
<td width="276">±5 % of mv (401 to 2000 ppm)</td>
</tr>
<tr>
<td width="276">±10 % of mv (2001 to 4000 ppm)</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Resolution</td>
<td style="font-style: inherit;" width="276">1 ppm</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Reaction time</td>
<td style="font-style: inherit;" width="276">60 s</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2" width="651"><strong>General technical data</strong></td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Dimensions</td>
<td style="font-style: inherit;" width="276">201 x 83 x 44 mm</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Operating temperature</td>
<td style="font-style: inherit;" width="276">-5 to +45 °C</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Display type</td>
<td style="font-style: inherit;" width="276">LCD</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Display function</td>
<td style="font-style: inherit;" width="276">Backlit 2-line display</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Power supply</td>
<td style="font-style: inherit;" width="276">Battery: 1500 mAh, mains unit 5V/1A</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Storage temperature</td>
<td style="font-style: inherit;" width="276">-20 to +50 °C</td>
</tr>
<tr style="font-style: inherit; font-weight: inherit;">
<td style="font-style: inherit;" width="375">Weight</td>
<td style="font-style: inherit;" width="276">(with probe) Approx. 700 g</td>
</tr>
</tbody>
</table>
<h3>Testo 310 Basic Flue Gas Analyser Standard Accessories</h3>
<div class="row"  id="row-247377197">

	<div id="col-1034372594" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<ul>
<li>lithium battery</li>
<li>sensors</li>
<li>probe with cone</li>
<li>hose</li>
<li>silicon tubing (for pressure)</li>
<li>extra particulate filters (5),</li>
<li>AC power supply (USB)</li>
<li>calibration protocol certificate</li>
<li>case.</li>
</ul>
		</div>
					</div>

	

	<div id="col-1970900526" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<img loading="lazy" decoding="async" class="alignnone size-medium wp-image-13428" src="https://rapid-tech.com.au/wp-content/uploads/2019/12/Testo-310-set-300x300.jpg" alt="" width="300" height="300" srcset="https://rapid-tech.com.au/wp-content/uploads/2019/12/Testo-310-set-300x300.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2019/12/Testo-310-set-100x100.jpg 100w, https://rapid-tech.com.au/wp-content/uploads/2019/12/Testo-310-set-150x150.jpg 150w, https://rapid-tech.com.au/wp-content/uploads/2019/12/Testo-310-set.jpg 600w" sizes="auto, (max-width: 300px) 100vw, 300px" /></p>
		</div>
					</div>

	
</div>
<p>The post <a href="https://rapid-tech.com.au/testo-310-basic-flue-gas-analyser/">Testo 310 Basic Flue Gas Analyser</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>CEM DT-9881 Air Particle Counter + Gas Detector</title>
		<link>https://rapid-tech.com.au/cem-dt-9881-air-particle-counter-gas-detector/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Fri, 15 Mar 2019 03:21:50 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=10194</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-9810" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/CEM-Logo-medium.jpg" alt="" width="150" height="66" /></p>
<p>The CEM DT-9881 Air Particle Counter with 2.8”color TFT LCD display &#38;  microSD memory card can capture images (JPEG) or video (3GP) for viewing on your PC, providing  fast, easy and accurate readings for particle counter,plus  <strong style="color: #333333;">GAS Formaldehyde (HCHO) &#38; Carbon Monoxide (CO) detectors,</strong> air temperature &#38; relative humidity, most surface temperature measurements.</p>
<h4><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" />    <span style="text-decoration: underline;"><span style="font-size: 110%;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2019/03/DT-9881-User-Manual.pdf" rel="noopener noreferrer">DT-9881-User-Manual</a></span></span></h4>
<p>The post <a href="https://rapid-tech.com.au/cem-dt-9881-air-particle-counter-gas-detector/">CEM DT-9881 Air Particle Counter + Gas Detector</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>THE CEM DT-9881 Air Particle Counter + Gas Detector provides fast,easy and accurate readings for particle count, <strong style="color: #333333;">GAS Formaldehyde (HCHO) &amp; Carbon Monoxide (CO) </strong>detectection, air temperature &amp; relative humidity &amp;,most surface temperature measurements.<br />
It is the ideal instrument for environmental and energy saving surveys.</p>
<h4><strong>CEM DT-9881 Air Particle Counter + Gas Detector Features:</strong></h4>
<ul>
<li>2.8&#8243; TFT 320&#215;240 pixels Color LCD display</li>
<li>Images(JPEG) &amp; Video(3GP)</li>
<li><strong>Simultaneously measure and display 6 channel of particle sizes, measure particle size down to 0.3 </strong><strong>μm</strong></li>
<li>IR temperature measure &amp; Laser targeting</li>
<li><strong>GAS Formaldehyde (HCHO) &amp; Carbon Monoxide (CO) detectors</strong></li>
<li><strong>Air temperature and humidity, Dew point &amp; Wet bulb temperature</strong></li>
<li>Max, Min, DIF, AVG record, Date/time setup controls, High and low alarm</li>
<li>Adjustable emissivity &amp; Trigger lock</li>
<li>MicroSD (MAX. use 8GB) memory card, USB interface</li>
<li>Auto Power Off</li>
<li>Selectable sample time, count data, programmable delay</li>
<li>Store 5000 records of date, time, counts, relative humidity, temperature, sample volumes, alarms and location label</li>
<li>Language selection English, Chinese, French, German, Spanish</li>
</ul>
<h4><strong>CEM DT-9881 Air Particle Counter + Gas Detector Specifications:</strong></h4>
<table border="1" cellspacing="0" cellpadding="1">
<tbody>
<tr>
<td colspan="2"><strong> Particle Counter</strong></td>
</tr>
<tr>
<td><span lang="EN-US">Channel</span></td>
<td><span lang="EN-US">0.3, 0.5, 1.0, 2.5, 5.0, 10μm</span></td>
</tr>
<tr>
<td><span lang="EN-US">Flow Rate</span></td>
<td><span lang="EN-US">0.1ft3(2.83L/min) controlled by internal pump</span></td>
</tr>
<tr>
<td><span lang="EN-US">Count Modes</span></td>
<td><span lang="EN-US">Totalize, Concentration, Audio</span></td>
</tr>
<tr>
<td><span lang="EN-US">Coincidence Loss</span></td>
<td><span lang="EN-US">5%, 2000000 particles per ft3</span></td>
</tr>
<tr>
<td colspan="2"><strong> IR Temperature Measure</strong></td>
</tr>
<tr>
<td><span lang="EN-US">IR Temp. Range</span></td>
<td>-20.0ºC to 500.0ºC<br />
Basic Accuracy: ±1.5% of reading</td>
</tr>
<tr>
<td><span lang="EN-US">Optical Resolution</span></td>
<td><span lang="EN-US">8:1 Distance to Spot size</span></td>
</tr>
<tr>
<td><span lang="EN-US">Emissivity Adjustable</span></td>
<td><span lang="EN-US">0.10~1.0 Adjustable</span></td>
</tr>
<tr>
<td><span lang="EN-US">Response Time</span></td>
<td><span lang="EN-US">500mS</span></td>
</tr>
<tr>
<td colspan="2"><strong> Air Temperature Measure</strong></td>
</tr>
<tr>
<td><span lang="EN-US">Air Temp Range</span></td>
<td><span lang="EN-US">0 to 50ºC; Basic Accuracy:±0.5ºC</span></td>
</tr>
<tr>
<td><span lang="EN-US">Humidity Range</span></td>
<td><span lang="EN-US">0 to 100%RH; Basic Accuracy:±2.5%RH(20%~80%RH)</span></td>
</tr>
<tr>
<td><span lang="EN-US">Dew Point Temp. Range</span></td>
<td><span lang="EN-US">-30~100ºC</span></td>
</tr>
<tr>
<td><span lang="EN-US">Wet Bulb Temp. Range</span></td>
<td><span lang="EN-US">0~80ºC</span></td>
</tr>
<tr>
<td colspan="2"><strong> GAS Detectors</strong></td>
</tr>
<tr>
<td><span lang="EN-US">HCHO Range</span></td>
<td><span lang="EN-US">0.01~5.00ppm; Basic Accuracy: ±5%± 0.01ppm</span></td>
</tr>
<tr>
<td><span lang="EN-US">CO (carbon monoxide) Range</span></td>
<td><span lang="EN-US">0~1000ppm; Basic Accuracy:±5% ± 10ppm</span></td>
</tr>
<tr>
<td colspan="2"><strong> Other</strong></td>
</tr>
<tr>
<td>Battery</td>
<td>Rechargeable battery(Could be use 4 hours)</td>
</tr>
<tr>
<td>Charging time</td>
<td>2 hours</td>
</tr>
<tr>
<td>Size</td>
<td>240*75*57mm</td>
</tr>
<tr>
<td>Weight</td>
<td>570g</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/cem-dt-9881-air-particle-counter-gas-detector/">CEM DT-9881 Air Particle Counter + Gas Detector</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
