<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Insulation Testers Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/insulation-testers-portablehandheld/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/insulation-testers-portablehandheld/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Tue, 24 Jun 2025 06:53:31 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.5</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>Insulation Testers Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/insulation-testers-portablehandheld/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>YOKOGAWA MY600 Digital Insulation Tester &#8211; 1000V</title>
		<link>https://rapid-tech.com.au/yokogawa-my600-digital-insulation-tester-1000v/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Thu, 12 Jul 2018 21:09:00 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=8238</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/10/Yokogawa-Logo-Medium.jpg"><img class="alignnone size-full wp-image-5623" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/Yokogawa-Logo-Medium.jpg" alt="" width="250" height="50" /></a></p>
<p>The MY600 Digital Insulation Tester has enhanced operation compared to the conventional model, by using a shortened measurement time and color indicating judging function. This is a new concept in insulation testing and includes enhanced communication to a PC or tablet.</p>
<p>The MY600 has six test voltages, 50V, 100V, 125V, 250V, 500V, 1000V</p>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2018/07/Yokogawa-MY600-Datasheet.pdf" rel="noopener noreferrer"><span style="font-size: 110%;">Yokogawa MY600 Datasheet</span></a></span></h4>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><span style="font-size: 110%;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2018/07/Yokogawa-MY600-User-Manual.pdf" rel="noopener noreferrer">Yokogawa MY600 User Manual</a></span></span></h4>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-my600-digital-insulation-tester-1000v/">YOKOGAWA MY600 Digital Insulation Tester &#8211; 1000V</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4><span style="font-size: 110%;">YOKOGAWA MY600 Digital Insulation Tester Features</span></h4>
<ul>
<li>The YOKOGAWA MY600 is equipped with an LCD backlight and LED spot light to facilitate working at dimly illuminated location or at night. The built-in illuminance sensor automatically turns on/ off the lights. An auto light-off function is also available to turn off these lights automatically if there is no user interaction for two minutes. These lights can also be set to off at all times.</li>
<li>The instrument has an auto power-off function that automatically turns itself off if there is no user interaction for 10 minutes. This function is not activated when a continuous measurement is in progress.</li>
<li>A test probe with a remote switch is supplied as a standard accessory.</li>
<li>A shoulder strap can be used for two-hand operation.</li>
<li>Live circuit warning is indicated with a blinking symbol and buzzer sound.</li>
<li>In voltage measurement, live circuit warning is indicated at a voltage input of 30 V or higher. In addition, whether the input voltage is AC or DC is automatically detected and indicated.</li>
<li>An auto discharge function is provided. When measuring an insulation resistance, like a capacitive load, electric charges stored in capacitive circuits are automatically discharged after measurement. The discharge status is indicated with a blinking symbol and buzzer sound.</li>
<li>In insulation resistance measurement, blinking LCD backlight indicates whether a measured value is less than or higher than the reference value. This pass/fail<br />
judgment function can be turned off.</li>
<li>To prevent mistakes in operation, an empty range is provided between the 500 V and 1000 V ranges of the range switch.</li>
<li> Intermittent warning buzzer sounds when the range switch is set to 1000 V range.</li>
<li><strong>Hold function</strong><br />
A measured insulation or low-resistance value is held and displayed until the range is changed or another measurement is started.</li>
<li><strong> 0Ω adjustment function</strong><br />
In low-resistance measurements, the resistance of the cord and fuse can be cancelled up to about 3 Ω.</li>
<li><strong>Elapsed time display</strong><br />
The measurement time is displayed upon starting an insulation resistance measurement.</li>
<li><strong>One-minute value display</strong><br />
The measurement 1 minute after starting an insulation resistance measurement can be displayed.</li>
<li><strong> Dielectric Absorption Ratio (DAR)/Polarization Index (PI) measurement</strong><br />
DAR and PI values are calculated automatically during an insulation resistance measurement.</li>
<li><strong>Memory function</strong><br />
Measured data can be saved, loaded, and deleted from the internal memory.</li>
<li><strong>Communication function</strong><br />
Data saved in the internal memory can be transferred to a PC using communication.</li>
<li><strong>Clock</strong><br />
Measured data is saved with the measurement time information.</li>
</ul>
<h4>Two colors for judging measurement results</h4>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2018/07/MY600-Pass-Fail-Display.jpg"><img decoding="async" class="alignnone wp-image-8239 size-full" src="https://rapid-tech.com.au/wp-content/uploads/2018/07/MY600-Pass-Fail-Display.jpg" alt="" width="469" height="94" srcset="https://rapid-tech.com.au/wp-content/uploads/2018/07/MY600-Pass-Fail-Display.jpg 469w, https://rapid-tech.com.au/wp-content/uploads/2018/07/MY600-Pass-Fail-Display-300x60.jpg 300w" sizes="(max-width: 469px) 100vw, 469px" /></a><br />
Set a desired reference value with the comparator function, and it will judge PASS (Green) or FAIL (Red) of a measurement result.</p>
<h4>Insulation deterioration diagnosis (PI and DAR measurement*)</h4>
<p>The increase and decrease of resistance value can be measured by continuously measuring the insulation resistance for a prescribed time. The insulation deterioration of the unit under test can be diagnosed by this increase/decrease. This parameter is useful for preventive maintenance of industrial automation equipment such as Magnetic Flow Meters or electrical equipment.<br />
<span style="font-size: 75%;">*PI: Polarization Index (Resistance after 1 minute/Resistance after 10 minutes)</span><br />
<span style="font-size: 75%;">DAR: Dielectric Absorption Rate (Resistance after 15 seconds/Resistance after 1 minute)</span></p>
<h4>Auto lighting backlight and LED light</h4>
<p>YOKOGAWA MY600 has a backlight that automatically lights up in a dark place, as well as an LED light to illuminate the work area.</p>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2018/07/YEW-MY600-Display.jpg"><img fetchpriority="high" decoding="async" class="alignnone wp-image-8240" src="https://rapid-tech.com.au/wp-content/uploads/2018/07/YEW-MY600-Display.jpg" alt="" width="400" height="339" srcset="https://rapid-tech.com.au/wp-content/uploads/2018/07/YEW-MY600-Display.jpg 611w, https://rapid-tech.com.au/wp-content/uploads/2018/07/YEW-MY600-Display-300x254.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2018/07/YEW-MY600-Display-600x509.jpg 600w" sizes="(max-width: 400px) 100vw, 400px" /></a></p>
<p>&nbsp;</p>
<h4>USB communication and memory function</h4>
<p>PC communication is possible with the dedicated USB communication adaptor (91030). Users can save as many as 1000 measurements to the internal memory from which data required for report generation, such as measurement data/time, measured value and range can be transmitted to a PC via communication.</p>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2018/07/MY600-Communicatios.jpg"><img decoding="async" class="alignnone wp-image-8242 size-full" src="https://rapid-tech.com.au/wp-content/uploads/2018/07/MY600-Communicatios.jpg" alt="" width="820" height="120" srcset="https://rapid-tech.com.au/wp-content/uploads/2018/07/MY600-Communicatios.jpg 820w, https://rapid-tech.com.au/wp-content/uploads/2018/07/MY600-Communicatios-300x44.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2018/07/MY600-Communicatios-600x88.jpg 600w, https://rapid-tech.com.au/wp-content/uploads/2018/07/MY600-Communicatios-768x112.jpg 768w" sizes="(max-width: 820px) 100vw, 820px" /></a></p>
<div class="row"  id="row-436754686">

	<div id="col-290191665" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<p>&nbsp;</p>
<h4>Line probe with switch is provided as a standard accessory</h4>
<p>Users can turn measurement on/off with the hand switch on the line probe, allowing them work more efficiently</p>
		</div>
					</div>

	

	<div id="col-1032858380" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<a href="https://rapid-tech.com.au/wp-content/uploads/2018/07/MY600-Probe.jpg"><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-8241" src="https://rapid-tech.com.au/wp-content/uploads/2018/07/MY600-Probe-300x203.jpg" alt="" width="300" height="203" srcset="https://rapid-tech.com.au/wp-content/uploads/2018/07/MY600-Probe-300x203.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2018/07/MY600-Probe.jpg 401w" sizes="auto, (max-width: 300px) 100vw, 300px" /></a></p>
		</div>
					</div>

	
</div>
<h4>YOKOGAWA MY600 Specifications:</h4>
<table>
<tbody>
<tr>
<td width="172">Rated measuring voltage</td>
<td width="87">50 V</td>
<td width="87">100 V*</td>
<td width="89">125 V*</td>
<td width="88">250 V</td>
<td width="83">500 V</td>
<td width="65">1000 V</td>
<td width="23"></td>
</tr>
<tr>
<td width="172"></td>
<td width="87"></td>
<td width="87"></td>
<td width="89"></td>
<td width="88"></td>
<td width="83"></td>
<td width="65"></td>
<td width="23"></td>
</tr>
<tr>
<td width="172">Maximum effective reading</td>
<td width="87">100 MΩ</td>
<td width="87">200 MΩ</td>
<td width="89">250 MΩ</td>
<td width="88">500 MΩ</td>
<td width="83">2000 MΩ</td>
<td width="65">4000 MΩ</td>
<td width="23"></td>
</tr>
<tr>
<td width="172"></td>
<td width="87"></td>
<td width="87"></td>
<td width="89"></td>
<td width="88"></td>
<td width="83"></td>
<td colspan="2" width="88"></td>
</tr>
<tr>
<td width="172">First effective measurement range</td>
<td width="87">0.100 to 10.00 MΩ</td>
<td width="87">0.100 to 20.00 MΩ</td>
<td width="89">0.100 to 25.00 MΩ</td>
<td width="88">0.100 to 50.0 MΩ</td>
<td width="83">0.100 to 500 MΩ</td>
<td colspan="2" width="88">0.100 to 1000 MΩ</td>
</tr>
<tr>
<td width="172"></td>
<td width="87"></td>
<td width="87"></td>
<td colspan="2" width="177"></td>
<td width="83"></td>
<td width="65"></td>
<td width="23"></td>
</tr>
<tr>
<td width="172">Accuracy</td>
<td width="87"></td>
<td width="87"></td>
<td colspan="2" width="177">±2% reading ±2 digit</td>
<td width="83"></td>
<td width="65"></td>
<td width="23"></td>
</tr>
<tr>
<td width="172"></td>
<td width="87"></td>
<td width="87"></td>
<td width="89"></td>
<td width="88"></td>
<td width="83"></td>
<td width="65"></td>
<td width="23"></td>
</tr>
<tr>
<td width="172">Second effective measurement range</td>
<td width="87">10.01 to 100.0 MΩ</td>
<td width="87">20.01 to 200.0 MΩ</td>
<td width="89">25.01 to 250.0 MΩ</td>
<td width="88">50.1 to 500 MΩ</td>
<td width="83">501 to 2000 MΩ</td>
<td width="65">1001 to 4000</td>
<td width="23">MΩ</td>
</tr>
<tr>
<td width="172"></td>
<td width="87"></td>
<td width="87"></td>
<td colspan="2" width="177"></td>
<td width="83"></td>
<td width="65"></td>
<td width="23"></td>
</tr>
<tr>
<td width="172">Accuracy</td>
<td width="87"></td>
<td width="87"></td>
<td colspan="2" width="177">±5% reading</td>
<td width="83"></td>
<td width="65"></td>
<td width="23"></td>
</tr>
<tr>
<td width="172"></td>
<td width="87"></td>
<td width="87"></td>
<td colspan="2" width="177"></td>
<td width="83"></td>
<td width="65"></td>
<td width="23"></td>
</tr>
<tr>
<td width="172"></td>
<td width="87"></td>
<td width="87"></td>
<td colspan="2" width="177">0.050 to 0.099 MΩ: ±2% reading ±4 digit</td>
<td width="83"></td>
<td width="65"></td>
<td width="23"></td>
</tr>
<tr>
<td width="172"></td>
<td width="87"></td>
<td width="87"></td>
<td colspan="2" width="177"></td>
<td width="83"></td>
<td width="65"></td>
<td width="23"></td>
</tr>
<tr>
<td width="172">Other ranges accuracy</td>
<td width="87"></td>
<td width="87"></td>
<td colspan="2" width="177">0.000 to 0.049 MΩ: ±2% reading ±6 digit</td>
<td width="83"></td>
<td width="65"></td>
<td width="23"></td>
</tr>
</tbody>
</table>
<h4>Standard Accessories</h4>
<p><strong>The following accessories are included. </strong><br />
Carrying case<br />
Line probe with remote switch<br />
Earth probe set<br />
Shoulder strap<br />
Alkaline dry cell x 4<br />
User Manual</p>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-my600-digital-insulation-tester-1000v/">YOKOGAWA MY600 Digital Insulation Tester &#8211; 1000V</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Yokogawa 2406E Series (Multi Range) Analogue Insulation Tester</title>
		<link>https://rapid-tech.com.au/yokogawa-2406e-series-multi-range-analogue-insulation-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 07 Nov 2017 15:36:03 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=5832</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/10/Yokogawa-Logo-Medium.jpg"><img class="alignnone size-full wp-image-5623" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/Yokogawa-Logo-Medium.jpg" alt="" width="250" height="50" /></a></p>
<p>The Yokogawa 2406E Series Analog Insulation Testers have two and three ratings available. The 2406E has a max AC voltage measuring range of 0 to 600V. The tester automatically begins discharge when you turn off the MEAS switch.</p>
<p>The Yokogawa 2406E Analogue Insulation Tester Features:</p>
<ul>
<li>Analogue models with two and three rating</li>
<li>AC voltage measurement</li>
<li>Automatic discharge</li>
<li>Sky blue EL backlight</li>
<li>Increased safety (covered battery charger)</li>
</ul>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg"><img class="alignnone size-full wp-image-5776" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg" alt="" width="200" height="186" /></a></p>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="color: #0000ff;"><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/Yokogawa-2406E-Datasheet.pdf">Yokogawa 2406E Datasheet</a></span></h3>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-2406e-series-multi-range-analogue-insulation-tester/">Yokogawa 2406E Series (Multi Range) Analogue Insulation Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Yokogawa 2406E Series (Multi Range) Analogue Insulation Tester</h3>
<p>The Yokogawa 2406E Series Analog Insulation Testers have two and three ratings available. The 2406E has a max AC voltage measuring range of 0 to 600V. The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (∞) scale value. Under this condition, the tester is ready to enter voltage measurement mode.</p>
<p><b>Discharge Function:<br />
</b>The tester automatically discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit breaker under test. You can make sure the discharge is complete by checking that the pointer swings back to the infinate (∞) scale value. Under this condition, the tester is ready to enter voltage measurement mode.</p>
<p><b>AC Voltage Measurement:<br />
</b>The tester enters AC Voltage measurement Mode is available wherever the rotary switch is positioned.</p>
<p><b>Dimensions (main unit):</b><br />
Approx. 120(W) x 110(H) x 60(D)mm</p>
<p><b>Weight:</b><br />
Approx. 500g (main unit and batteries only)</p>
<p><strong>Yokogawa 2406E Series Specifications:</strong></p>
<table id="Range" style="height: 431px;" border="1" width="737" cellspacing="1" cellpadding="2">
<tbody>
<tr align="middle">
<td><strong>Model</strong></td>
<td><strong>Rating</strong></td>
<td><strong>Measuring Range</strong></td>
<td><strong>AC Voltage Measuring Range</strong></td>
</tr>
<tr>
<td style="text-align: center;">240631 240641</td>
<td>25V/5MΩ 50V/10MΩ 125V/20MΩ</td>
<td>0.001 to 5MΩ 0.005 to 10MΩ 0.01 to 20MΩ</td>
<td>0 to 300V</td>
</tr>
<tr>
<td style="text-align: center;">240632 240642</td>
<td>125V/20MΩ 250V/50MΩ</td>
<td>0.01 to 20MΩ 0.01 to 50MΩ</td>
<td>0 to 300V</td>
</tr>
<tr>
<td style="text-align: center;">240633 240643</td>
<td>125V/20MΩ 250V/50MΩ 500V/100MΩ</td>
<td>0.01 to 20MΩ 0.01 to 50MΩ 0.05 to 100MΩ</td>
<td>0 to 600V</td>
</tr>
<tr>
<td style="text-align: center;">240634 240644</td>
<td>250V/50MΩ 500V/100MΩ 1000V/2000MΩ</td>
<td>0.01 to 50MΩ 0.05 to 100MΩ 1 to 2000MΩ</td>
<td>0 to 600V</td>
</tr>
<tr>
<td style="text-align: center;">240635 240645</td>
<td>250V/50MΩ 500V/100MΩ 1000V/2000MΩ</td>
<td>0.01 to 50MΩ 0.05 to 100MΩ 1 to 2000MΩ</td>
<td>0 to 600V</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-2406e-series-multi-range-analogue-insulation-tester/">Yokogawa 2406E Series (Multi Range) Analogue Insulation Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Yokogawa MY40-01 Digital Insulation Tester</title>
		<link>https://rapid-tech.com.au/yokogawa-my40-01-digital-insulation-tester/</link>
					<comments>https://rapid-tech.com.au/yokogawa-my40-01-digital-insulation-tester/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:12:23 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/yokogawa-my40-01-digital-insulation-tester/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-33" src="http://rapid-tech.com.au/wp-content/uploads/2015/12/Yokogawa_logo_sml.jpg" alt="Yokogawa_logo_sml" width="110" height="20" /></p>
<table border="0" width="650" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2">
<h4>Yokogawa MY4001 Digital Insulation Tester</h4>
</td>
</tr>
<tr>
<td rowspan="2">
<ul>
<li>Four Test Voltages (125V, 250V, 500V &#38; 1000V)</li>
<li>Insulation resistance: AC voltage and conductor resistance measurement</li>
<li>Insulation test mode: Comparator, memory, auto-hold and discharge function</li>
<li>All test modes: Live-line alarm (Exchange AC voltage measurement)</li>
<li>Easy to view, function-free display</li>
<li>Double-action safety mechanism</li>
<li>
<h4 style="text-align: left;">Includes Carrying Case (93015)</h4>
</li>
<li>
<h4 style="text-align: center;"><a href="https://rapid-tech.com.au/yokogawa-my600-digital-insulation-tester-1000v/"><span style="text-decoration: underline;"><span style="color: #ff0000; text-decoration: underline;">See also the Yokogawa MY600</span></span></a></h4>
</li>
</ul>
</td>
</tr>
</tbody>
</table>
<h4></h4>
<h4 style="text-align: center;"></h4>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-my40-01-digital-insulation-tester/">Yokogawa MY40-01 Digital Insulation Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<table border="0" width="650" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2">
<h3>Yokogawa MY40-01 Features:</h3>
<p><b>Display:<br />
</b>3 1/2-digit LCD; 4000 count; backlight-illuminated; logarithmic bar graph; extension bar graph–no fluctuations, as the display shows the digits of a reading in the order in which each digit settles.</p>
<p><b>Comparator function:<br />
</b>The MY40 alerts you by turning on the LOW symbol and sounding the buzzer if the measured value is smaller than the reference value. You can allocate as many as three user-defined reference values to each rating. The factory-set defaults are 0.1 MΩ, 0.2 MΩ and 0.4 MΩ.</p>
<p><b>Memory function:<br />
</b>For each rating, you can save as many as 20 measurements at desired memory address numbers.</td>
</tr>
<tr>
<td colspan="2"><b>Automatic discharge function:<br />
</b>The MY40 automatically begins discharge when you turn off the MEAS switch. You can monitor the state of discharge by checking the bar graph and make sure discharge is complete by checking that the segment bar disappear.<b>High-voltage indicators:<br />
</b>The high-voltage symbol and LED lamp come on to alert you when the MY40 is in insulation testing mode or if any voltage remains to be discharged.<b>Live-line alarm:<br />
</b>If you apply an AC voltage of approximately 40 V or higher across the input terminals, the MY40 alerts you by blinking the LED lamp and sounding the buzzer.<b>Over range input alarm:</b><br />
If the voltage being measured exceeds 600 V during AC voltage measurement, the MY40 alerts you by flashing the Maximum Value indicator and sounding the buzzer.</p>
<p><b>Auto-hold function:<br />
</b>The tester retains the measured resistance for approximately 5 seconds after the MEAS switch is turned off.</td>
</tr>
</tbody>
</table>
<table border="0" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="2"><strong><span style="font-size: medium;">Specifications</span></strong></td>
</tr>
<tr>
<td colspan="2">
<div align="center">
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td align="center" bgcolor="#B4CDCD" width="187"><b>Model<br />
</b></td>
<td align="center" bgcolor="#B4CDCD" width="187"><b>Rating<br />
</b></td>
<td align="center" bgcolor="#B4CDCD" width="188"><b>Measuring Range<br />
</b></td>
<td align="center" bgcolor="#B4CDCD" width="188"><b>AC Measuring Range<br />
</b></td>
</tr>
<tr>
<td rowspan="12" align="center" bgcolor="#C0D9D9" width="187">MY40-01<b></b></p>
<p>&nbsp;</td>
<td rowspan="3" bgcolor="#C0D9D9" width="187">125V/200M<span style="font-family: Verdana;">Ω</span></p>
<p>&nbsp;</td>
<td bgcolor="#C0D9D9" width="188">0 to .0199M<span style="font-family: Verdana;">Ω</span></td>
<td rowspan="3" align="center" bgcolor="#C0D9D9" width="188">0 to 600V AC</td>
</tr>
<tr>
<td bgcolor="#C0D9D9" width="188"><span style="font-family: Verdana;">.0200 to 20.00MΩ*</span></td>
</tr>
<tr>
<td bgcolor="#C0D9D9" width="188"><span style="font-family: Verdana;">20.01 to 200.0MΩ</span></td>
</tr>
<tr>
<td rowspan="3" bgcolor="#C0D9D9" width="187">250V / 200M<span style="font-family: Verdana;">Ω</span></p>
<p>&nbsp;</td>
<td bgcolor="#C0D9D9" width="188">0 to .0499M<span style="font-family: Verdana;">Ω</span></td>
<td rowspan="3" align="center" bgcolor="#C0D9D9" width="188">0 to 600V AC</td>
</tr>
<tr>
<td bgcolor="#C0D9D9" width="188"><span style="font-family: Verdana;">.0500 to 20.00MΩ*</span></td>
</tr>
<tr>
<td bgcolor="#C0D9D9" width="188"><span style="font-family: Verdana;">20.01 to 200.0MΩ</span></td>
</tr>
<tr>
<td rowspan="3" bgcolor="#C0D9D9" width="187">500V / 2000<span style="font-family: Verdana;">Ω</span></p>
<p>&nbsp;</td>
<td bgcolor="#C0D9D9" width="188">0 to 0.999M<span style="font-family: Verdana;">Ω</span></td>
<td rowspan="3" align="center" bgcolor="#C0D9D9" width="188">0 to 600V AC</td>
</tr>
<tr>
<td bgcolor="#C0D9D9" width="188"><span style="font-family: Verdana;">1.000 to 500MΩ*</span></td>
</tr>
<tr>
<td bgcolor="#C0D9D9" width="188"><span style="font-family: Verdana;">501 to 2000MΩ</span></td>
</tr>
<tr>
<td rowspan="3" bgcolor="#C0D9D9" width="187">1000V /2000<span style="font-family: Verdana;">Ω</span></p>
<p>&nbsp;</td>
<td bgcolor="#C0D9D9" width="188">0 to 1.999M<span style="font-family: Verdana;">Ω</span></td>
<td rowspan="3" align="center" bgcolor="#C0D9D9" width="188">0 to 600V AC</td>
</tr>
<tr>
<td bgcolor="#C0D9D9" width="188"><span style="font-family: Verdana;">2000 to 1000MΩ*</span></td>
</tr>
<tr>
<td bgcolor="#C0D9D9" width="188"><span style="font-family: Verdana;">1001 to 2000MΩ</span></td>
</tr>
</tbody>
</table>
</div>
</td>
</tr>
<tr>
<td colspan="2">
<div align="center">
<table border="0" width="100%" cellpadding="0">
<tbody>
<tr>
<td width="59"><b><i>Note **</i></b></td>
<td><b><i>First effective measuring range</i></b></td>
</tr>
</tbody>
</table>
</div>
</td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2"><strong><span style="font-size: medium;">General Specifications</span></strong></td>
</tr>
<tr>
<td colspan="2">
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td bgcolor="#B4CDCD" width="195">Display</td>
<td bgcolor="#C0D9D9" width="593">3<span style="font-family: Verdana;">½-digit LCD; 4000 count; backlight-illuminated bar graph; extension bar graph-no fluctuations, as the display shows the digit of a reading in the order in which each digit settles.</span></td>
</tr>
<tr>
<td bgcolor="#B4CDCD" width="195">Comparator Function</td>
<td bgcolor="#C0D9D9" width="593">The MY40 alerts you by turning on the LOW symbol and sounding the buzzer if the measured value is smaller than reference value. You can allocate as many as three user-defined reference values to each rating. The factory-set defaults are 0.1M<span style="font-family: Verdana;">Ω, 0.2MΩ, and 0.4MΩ.</span></td>
</tr>
<tr>
<td bgcolor="#B4CDCD" width="195">Memory Function</td>
<td bgcolor="#C0D9D9" width="593">For each rating, you can save as many as 20 measurements at desired memory address numbers.</td>
</tr>
<tr>
<td bgcolor="#B4CDCD" width="195">Automatic Discharge Function</td>
<td bgcolor="#C0D9D9" width="593">The MY40 automatically begins discharge when you turn off the MEAN switch. You can monitor the state of discharge by checking the bar graph and make sure discharge is complete by checking that the segment bar disappear.</td>
</tr>
<tr>
<td bgcolor="#B4CDCD" width="195">High-Voltage Indicators</td>
<td bgcolor="#C0D9D9" width="593">The high-voltage symbol and LED lamp come on to alert you when the MY40 is in insulation testing mode or if any voltage remains to be discharged.</td>
</tr>
<tr>
<td bgcolor="#B4CDCD" width="195">Live-Line Alarm</td>
<td bgcolor="#C0D9D9" width="593">If you apply an AC voltage of approximately 40V or higher across the input terminals, the MY40 alerts you by blinking the LED lamp and sounding buzzer.</td>
</tr>
<tr>
<td bgcolor="#B4CDCD" width="195">Overrange Input Alarm</td>
<td bgcolor="#C0D9D9" width="593">If the voltage being measured exceeds 600V during AC voltage measurement, the MY40 alerts you by flashing the Maximum Value indicator and sounding the buzzer.</td>
</tr>
<tr>
<td bgcolor="#B4CDCD" width="195">Auto-Hold Function</td>
<td bgcolor="#C0D9D9" width="593">The tester retains the measured resistance for approximately 5 seconds after the MEAS switch is turned off.</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2">
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td bgcolor="#B4CDCD" width="195">Power Supply</td>
<td bgcolor="#C0D9D9" width="593">Four (4) type &#8216;AA&#8217; Alkaline batteries.</td>
</tr>
<tr>
<td bgcolor="#B4CDCD" width="195">Dimensions</td>
<td bgcolor="#C0D9D9" width="593">125mm (W) x 103mm (H) x 53mm (D) excluding protrusions.</td>
</tr>
<tr>
<td bgcolor="#B4CDCD" width="195">Weight</td>
<td bgcolor="#C0D9D9" width="593">420g (main unit and batteries only, excluding accessories).</td>
</tr>
<tr>
<td bgcolor="#B4CDCD" width="195">Batteries</td>
<td bgcolor="#C0D9D9" width="593">Four AA (R6P) batteries.</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-my40-01-digital-insulation-tester/">Yokogawa MY40-01 Digital Insulation Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/yokogawa-my40-01-digital-insulation-tester/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>