<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Voltage Data Logger Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/voltage-data-logger/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/voltage-data-logger/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Tue, 24 Jun 2025 07:17:52 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.10</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>Voltage Data Logger Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/voltage-data-logger/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Kyoritsu 5020 TRMS 3-Channel Current / Voltage Data Logger</title>
		<link>https://rapid-tech.com.au/kyoritsu-5020-trms-3-channel-current-voltage-data-logger/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Thu, 24 May 2018 15:39:29 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=7660</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-9900" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/Kyoritsu-Premium-Authorised.jpg" alt="" width="250" height="69" /></p>
<p class="short-description mhide ipad-view-setting">The Kyoritsu 5020 TRMS Current/Voltage Data Logger has three input channels for the simultaneous recording of load current and voltage.</p>
<p class="short-description mhide ipad-view-setting">Various measurements are available with four recording modes: Normal, Trigger, Capture and Power Quality Analysis.</p>
<p>The Kyoritsu 5020 data logger is capable of storing up to 60,000 measurements and features non-volatile memory that allows recorded data to be retained even if power is lost.</p>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><span style="font-size: 110%;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-5020-Datasheet.pdf" rel="noopener">Kyoritsu 5020 Datasheet</a></span></span></h4>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>   <span style="text-decoration: underline;"><span style="font-size: 110%;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-5020-User-Manual.pdf" rel="noopener">Kyoritsu 5020 User Manual</a></span></span></h4>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-5020-trms-3-channel-current-voltage-data-logger/">Kyoritsu 5020 TRMS 3-Channel Current / Voltage Data Logger</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Kyoritsu 5020 TRMS 3-Channel Current / Voltage Data Logger Features:</h3>
<div class="row"  id="row-342033071">

	<div id="col-1188176311" class="col medium-2/3 large-8"  >
				<div class="col-inner"  >
			
			
<ul>
<li>Power Quality Analysis: Reference voltage, Swell, Dip, Short power Interruptions.</li>
<li>Variation of the measured voltage and current data can be confirmed simultaneously on the PC display monitor.</li>
<li>Large capacity for storing 60,000 data points when 1 channel is used, and when all the three channels are used, 20,000 data points per channel can be recorded.</li>
<li>Lowpass Filter will filter out the harmonics (cutoff frequency = approx. 160Hz)</li>
<li>LED flickers when the preset current / voltage value is exceeded</li>
</ul>
		</div>
					</div>

	

	<div id="col-1359856332" class="col medium-1/3 large-4"  >
				<div class="col-inner"  >
			
			
<a href="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-5020_01.jpg"><img decoding="async" class="alignnone wp-image-7664" src="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-5020_01.jpg" alt="" width="164" height="183" /></a><br />
		</div>
					</div>

	
</div>
<ul>
<li>The following can be displayed: number of recorded data points, (max+ min+ peak) value for each channel complete with time/date information in the Normal recording mode. (Detected values (i.e. when values are outside preset limits ) can be displayed in other recording modes)</li>
<li>The last 10 recorded data points including time/date can be recalled on the logger display</li>
<li>Selection of One-time mode or Endless mode:<br />
One-time on: Recording will stop when memory is used up<br />
One-time off: Overwrite the old data, and store the latest data</li>
<li>Non Volatile Memory: Recorded data will be retained even if the batteries are exhausted or replaced due to the presence of a nonvolatile memory (guaranteed for 10 years)</li>
<li>Battery power indicator: Indicates battery voltage in 4-levels (It is possible to use the logger for a further approx. 24 hours even after the warming symbol is flashing)</li>
<li>User-friendly PC software &#8220;KEW LOG Soft 2&#8221; is supplied</li>
<li>Permits editing, analysis and graphical display of data.</li>
<li>Recorded data is downloadable onto a PC via USB cable.</li>
<li>Simplified Power Integration: (The &#8220;KEW LOG Soft 2&#8221; uses current and voltage recorded to calculate the integral power consumption).</li>
</ul>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-5020-Recording-Modes.jpg"><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-7662" src="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-5020-Recording-Modes.jpg" alt="" width="945" height="783" srcset="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-5020-Recording-Modes.jpg 945w, https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-5020-Recording-Modes-300x249.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-5020-Recording-Modes-600x497.jpg 600w, https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-5020-Recording-Modes-768x636.jpg 768w" sizes="(max-width: 945px) 100vw, 945px" /></a></p>
<h4><span style="font-size: 110%;">Kyoritsu 5020 TRMS 3-Channel Data Logger Specifications:</span></h4>
<div class="editor">
<p>Normal Recording Mode<br />
(AC 50/60Hz, Sine wave, Input: 10% or more of the range at CH1)</p>
<div class="tableScroller">
<table>
<tbody>
<tr>
<th>Range</th>
<th>RMS Accuracy</th>
</tr>
<tr>
<td>100.0mA</td>
<td>±2.0%rdg±0.9%f.s.+ Accuracy of Sensor</td>
</tr>
<tr>
<td>Other ranges</td>
<td>±1.5%rdg±0.7%f.s.+ Accuracy of Sensor</td>
</tr>
<tr>
<td>Crest Factor</td>
<td>2.5 or less: RMS accuracy (sine) + 2%rdg + 1%f.s.</td>
</tr>
</tbody>
</table>
</div>
<p>*Max, Min and Instant Peak values in Normal Recording mode are just reference values:<br />
their accuracies aren&#8217;t guaranteed.</p>
<p>Trigger Recording Mode (AC 50/60Hz sine wave)</p>
<div class="tableScroller">
<table>
<tbody>
<tr>
<th>Range</th>
<th>Accuracy</th>
</tr>
<tr>
<td>100.0mA</td>
<td>±3.5%rdg±2.2%f.s.+ Accuracy of Sensor</td>
</tr>
<tr>
<td>Other ranges</td>
<td>±3.0%rdg±2.0%f.s.+ Accuracy of Sensor</td>
</tr>
</tbody>
</table>
</div>
<p>Capture Recording Mode</p>
<div class="tableScroller">
<table>
<tbody>
<tr>
<th>Range</th>
<th>Accuracy</th>
</tr>
<tr>
<td>100.0mA</td>
<td>±3.0%rdg±1.7%f.s.+ Accuracy of Sensor</td>
</tr>
<tr>
<td>Other ranges</td>
<td>±2.5%rdg±1.5%f.s.+ Accuracy of Sensor</td>
</tr>
</tbody>
</table>
</div>
</div>
<section class="mb10">
<div class="tableScroller">
<table class="specTable mb0">
<tbody>
<tr>
<th>Recording mode</th>
<td>Normal, Trigger, Capture, Power Quality Analysis</td>
</tr>
<tr>
<th>Operating system</th>
<td>Successive Approximation<br />
(CH1 single synchronized sampling)</td>
</tr>
<tr>
<th>Rated max. working voltage</th>
<td>AC 9.9Vrms, 14V peak value</td>
</tr>
<tr>
<th>Number of input channel</th>
<td>3ch</td>
</tr>
<tr>
<th>Measuring method</th>
<td>True RMS</td>
</tr>
<tr>
<th>RMS measuring interval</th>
<td>approx. 100ms</td>
</tr>
<tr>
<th>Sampling interval</th>
<td>Normal/Trigger mode : approx. 1.65ms/CH<br />
Capture mode : approx. 0.55ms (waveform: at every 1.1ms)<br />
P.Q.A. mode : approx. 0.55ms</td>
</tr>
<tr>
<th>Low battery warning</th>
<td>Battery mark display (in 4 levels)</td>
</tr>
<tr>
<th>Over-range indication</th>
<td>&#8220;OL&#8221; mark is displayed when exceeding the measuring range</td>
</tr>
<tr>
<th>Auto power off</th>
<td>Power-off function operates automatically after a switch remains for 3min. (when recording is stopped)</td>
</tr>
<tr>
<th>Possible measurement time</th>
<td>Approx. 10 days (with alkaline LR6 batteries)</td>
</tr>
<tr>
<th>Applicable standards</th>
<td>IEC 61010-1:2001 CAT III 300V Pollution degree2<br />
IEC 61326 (EMC standard)</td>
</tr>
<tr>
<th>Dimensions</th>
<td>111(L)×60(W)×42(D)mm</td>
</tr>
<tr>
<th>Weight</th>
<td>Approx. 265g</td>
</tr>
<tr>
<th>Included Accessories</th>
<td>Alkaline battery LR6×4pcs, 9118 (Carrying case)<br />
PC software &#8220;KEW LOG Soft 2&#8221;, 7148 (USB cable)<br />
Instruction manual, Quick manual, Install manual,<br />
USB Notice sheet</td>
</tr>
<tr>
<th>Optional Accessories</th>
<td>8146/8147/8148 (Leakage &amp; Load current Clamp Sensor),<br />
8121/8122/8123 (Load current Clamp Sensor),<br />
8129/8130 (Flexible Clamp Sensor),<br />
8309 (Voltage Sensor: only KEW 5020), 8320 (AC Adapter),<br />
9135 (Carrying bag), 9119 (Hard carry case),<br />
7185 (Extension cable for sensor)</td>
</tr>
</tbody>
</table>
</div>
</section>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-5020-trms-3-channel-current-voltage-data-logger/">Kyoritsu 5020 TRMS 3-Channel Current / Voltage Data Logger</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Extech DL160 Dual Input True RMS AC Voltage/Current Datalogger</title>
		<link>https://rapid-tech.com.au/extech-dl160-dual-input-true-rms-ac-voltagecurrent-datalogger/</link>
					<comments>https://rapid-tech.com.au/extech-dl160-dual-input-true-rms-ac-voltagecurrent-datalogger/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Mon, 11 Jul 2016 11:56:21 +0000</pubDate>
				<guid isPermaLink="false">http://rapid-tech.com.au/?post_type=product&#038;p=4050</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-8174" src="https://rapid-tech.com.au/wp-content/uploads/2018/06/Extech-Authorised-Distributor-1.jpg" alt="" width="250" height="77" /></p>
<p><a target="_blank" href="https://mymeter.com.au/product/extech-dl160-true-rms-ac-voltage-current-datalogger/" rel="noopener"><img class="alignnone size-full wp-image-17843" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/BUY-NOW-form-My-Meter-e1620004827208.png" alt="Buy now form My Meter" width="220" height="55" /></a></p>
<h4>Datalog up to 256,000 readings with user programmable sample rate</h4>
<p>The Extech DL160 is a Dual Input True RMS AC Voltage/Current Data logger. Simultaneously data log 2 channels of up to 256,000 readings of TRMS AC Voltage (600V) or Current (200A) or one AC Voltage and one AC Current input with a user programmable sample rate from 1 second to 24 hours. LCD displays time/date, current reading, and min/max.</p>
<p>&#160;</p>
<p><img class="alignnone size-full wp-image-2454" src="http://rapid-tech.com.au/wp-content/uploads/2016/04/CAT-III.jpg" alt="CAT III" width="46" height="33" />    <img class="alignnone size-full wp-image-2451" src="http://rapid-tech.com.au/wp-content/uploads/2016/04/Capture-2.jpg" alt="CE" width="37" height="30" />    <img class="alignnone size-full wp-image-2450" src="http://rapid-tech.com.au/wp-content/uploads/2016/04/1-Year.jpg" alt="1 Year" width="67" height="35" /></p>
<h5><img class="alignnone size-full wp-image-3188" src="http://rapid-tech.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" />    <span style="text-decoration: underline; color: #0000ff;"><strong><a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2016/07/DL160-Datasheet.pdf" rel="noopener">DL160 Datasheet</a></strong></span></h5>
<h5><img class="alignnone size-full wp-image-3188" src="http://rapid-tech.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" />    <a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2016/07/DL160-User-Manual.pdf" rel="noopener"><span style="text-decoration: underline; color: #0000ff;"><strong>DL160 User Manua</strong></span>l</a></h5>
<p>The post <a href="https://rapid-tech.com.au/extech-dl160-dual-input-true-rms-ac-voltagecurrent-datalogger/">Extech DL160 Dual Input True RMS AC Voltage/Current Datalogger</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>With the Extech DL160 Dual Input Voltage/Current datalogger you can monitor and log data (Voltage/Voltage, Current/Current or Voltage/Current) over long periods of time and then easily transfer the data to a pc for viewing and evaluation. The LCD display provides real time data, Max/Min data and time information.</p>
<p>Readings can be downloaded to your PC via the USB interface. Featuring Normal, Peak, and Capture (user specified trigger level) recording modes. Complete with 2 current clamps, two sets of test leads, 2 sets of alligator clips, software, USB cable, Universal AC Adapter, and 4 x AAA and 2 x CR2032 Batteries.</p>
<h4>Extech DL160 Dual Input True RMS AC Voltage/Current Datalogger Features:</h4>
<div>
<ul>
<li>Simultaneously measure two AC Voltage inputs or two AC Current inputs or one AC Voltage and one AC Current input</li>
<li>Readings can be downloaded to your PC via the USB interface and analyzed using the included software or exported to a spreadsheet</li>
<li>LCD indicates time/date, current readings and Min/Max</li>
<li>Auto Power off and battery check</li>
<li>Complete with 2 Current and Voltage sensor modules, two sets of test leads and alligator clips, USB cable, Windows® software, AC Adaptor and four AAA batteries</li>
</ul>
</div>
<p>The post <a href="https://rapid-tech.com.au/extech-dl160-dual-input-true-rms-ac-voltagecurrent-datalogger/">Extech DL160 Dual Input True RMS AC Voltage/Current Datalogger</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/extech-dl160-dual-input-true-rms-ac-voltagecurrent-datalogger/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT Italia XL424 True-Rms AC Three-Phase Voltage Logger</title>
		<link>https://rapid-tech.com.au/ht-italia-xl424-true-rms-ac-three-phase-voltage-logger/</link>
					<comments>https://rapid-tech.com.au/ht-italia-xl424-true-rms-ac-three-phase-voltage-logger/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sat, 16 Apr 2016 23:58:07 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=2845</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-974" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/HT-ITALIA-LOGO-1.png" alt="HT ITALIA LOGO" width="160" height="100" /></p>
<p>The XL424 is a 3 phase Voltage data logger that is capable of performing measurements and recordings of TRMS AC voltage up to 600V. It has a sophisticated memory algorithm allowing it to record for up to 90 days.</p>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/ht-italia-xl424-true-rms-ac-three-phase-voltage-logger/">HT Italia XL424 True-Rms AC Three-Phase Voltage Logger</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The HT Italia XL424 can perform measurements and recording of True-Rms AC voltage up to 600 volts in a three phase three-wire system. Applications include evaluation of network voltages and unbalanced loads etc. The instrument is contained in a safety IP65 case with built-in test leads and safety alligator clips for voltage measurements. The system can record for a very long time, up to around 90 days. With DATALINK Windows software supplied with the model, the recorded data is easily downloaded to a PC for analysis<span class="TXTSTANDARD">.</span></p>
<h4><span style="font-size: large;">HT Italia XL424 Functions:</span></h4>
<ul>
<li>True-rms AC voltage measurement up to 600V.</li>
<li>Recording with sampling programmable period.</li>
<li>Manual activation of recording.</li>
<li>Low battery indication.</li>
<li>LED indication of any operation.</li>
<li>RS-232 interface.</li>
<li>Data maintained without batteries.</li>
<li>Programming with DATALINK software.</li>
</ul>
<h4><span style="font-size: large;">Included Accessories</span></h4>
<ul>
<li>Set of two alligator clips, KITXL423C.</li>
<li>RS-232 serial cable, type C2004.</li>
<li>Adhesive Velcro for fixing.</li>
<li>Carrying bag, type BORSA2000.</li>
<li>User&#8217;s manual.</li>
</ul>
<table id="table88" border="1" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><span style="font-size: large;">Specifications </span>(accuracy stated at 23<span style="font-family: Verdana;">°C ±5°C ±(% of rdg + number of digits), &lt; 60% R.H.)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Measurement Range</td>
<td bgcolor="#C0C0C0">0 Volts to 600 Volts</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Resolution</td>
<td bgcolor="#C0C0C0">0.1 Volt</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Accuracy</td>
<td bgcolor="#C0C0C0"><span style="font-family: Verdana;">±(1.0% of reading + 2 digits)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Working Frequency</td>
<td bgcolor="#C0C0C0">50/60Hz <span style="font-family: Verdana;">±6%</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Type of Measurement</td>
<td bgcolor="#C0C0C0">True Rms</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Bandwidth</td>
<td bgcolor="#C0C0C0">3200Hz</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Maximum Crest Factor</td>
<td bgcolor="#C0C0C0">3</td>
</tr>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><i>Note: meter consider null readings &lt; 2 volts</i></td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><span style="font-size: large;">General Specifications</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Sampling Rate</td>
<td bgcolor="#C0C0C0">64 point, 20ms for each sampling period</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Sampling Period</td>
<td bgcolor="#C0C0C0">1 sec, 6 sec, 30 sec, 1 min, 5 min</td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Memory Capacity</td>
<td bgcolor="#C0C0C0">1 Mbyte<br />
Life in days (depending on batteries life):<br />
1.5 days/1 sec; 8 days/6 sec; 42 days/30 sec; 91 days/1 min;<br />
455 days/ 5 min</td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Computer Interface</td>
<td bgcolor="#C0C0C0">RS-232</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Operating Temperature/Humidity</td>
<td bgcolor="#C0C0C0">-20<span style="font-family: Verdana;">°C to 60°C; 0 to 100% R.H. (RS-232 connector closed)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Storage Temperature</td>
<td bgcolor="#C0C0C0">-20<span style="font-family: Verdana;">°C to 60°C; 0 to 100% R.H. (RS-232 connector closed)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Insulation</td>
<td bgcolor="#C0C0C0">class 2 (double insulation)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Protection Degree</td>
<td bgcolor="#C0C0C0">IP65 (RS-232 connector closed)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Maximum Altitude</td>
<td bgcolor="#C0C0C0">2000 meters</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td rowspan="2" valign="top" bgcolor="#C0C0C0" width="281">Reference Standards</td>
<td bgcolor="#C0C0C0">LVD: IEC/EN 61010-1 CAT III 1000V (to ground), CAT IV 600V (to ground)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0">EMC: IEC/EN 61326 (1997) +A1 (1998) +A2 (2001)</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Power Supply</td>
<td bgcolor="#C0C0C0">2 x 1.5 volt type &#8216;AA&#8217; alkaline batteries type LR6, AM3, MN1500</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Battery Life</td>
<td bgcolor="#C0C0C0">6 months</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Dimensions</td>
<td bgcolor="#C0C0C0">120mm (L) x 80mm (W) x 43mm (D)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Test Lead Length</td>
<td bgcolor="#C0C0C0">2.6 meters</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Weight</td>
<td bgcolor="#C0C0C0">500g (with internal batteries)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/ht-italia-xl424-true-rms-ac-three-phase-voltage-logger/">HT Italia XL424 True-Rms AC Three-Phase Voltage Logger</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/ht-italia-xl424-true-rms-ac-three-phase-voltage-logger/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT Italia XL423 True-Rms AC  Single-Phase Voltage Logger</title>
		<link>https://rapid-tech.com.au/ht-italia-xl423-true-rms-ac-single-phase-voltage-logger/</link>
					<comments>https://rapid-tech.com.au/ht-italia-xl423-true-rms-ac-single-phase-voltage-logger/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sat, 16 Apr 2016 23:52:46 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=2843</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-974" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/HT-ITALIA-LOGO-1.png" alt="HT ITALIA LOGO" width="160" height="100" /></p>
<p>The HT Italia XL423 is a single phase voltage date logger capable of performing measurements and recordings of TRMS AC voltage up to 600V. It has a sophisticated memory algorithm which allows it to record for up to 1 year.</p>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/ht-italia-xl423-true-rms-ac-single-phase-voltage-logger/">HT Italia XL423 True-Rms AC  Single-Phase Voltage Logger</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The HT Italia XL423 can perform measurements and recording of True-Rms AC voltage up to 600 volts in a single phase system. Applications include evaluation of network voltages and unbalanced loads etc. The instrument is contained in a safety IP65 case with built-in test leads and safety alligator clips for voltage measurements. The system can record for a very long time, up to around a year. With DATALINK Windows software supplied with the model, the recorded data is easily downloaded to a PC for analysis<span class="TXTSTANDARD">.</span></p>
<table id="table77" border="0" width="100%" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="42%">
<h4><span style="font-size: large;">HT Italia XL423 Functions:</span></h4>
<ul>
<li>True-rms AC voltage measurement up to 600V.</li>
<li>Recording with sampling programmable period.</li>
<li>Manual activation of recording.</li>
<li>Low battery indication.</li>
<li>LED indication of any operation.</li>
<li>RS-232 interface.</li>
<li>Data maintained without batteries.</li>
<li>Programming with DATALINK software.</li>
</ul>
<p>&nbsp;</p>
<h4><span style="font-size: large;">Included Accessories</span></h4>
<ul>
<li>Set of two alligator clips, KITXL423C.</li>
<li>RS-232 serial cable, type C2004.</li>
<li>Adhesive Velcro for fixing.</li>
<li>Carrying bag, type BORSA2000.</li>
<li>User&#8217;s manual.</li>
</ul>
</td>
</tr>
<tr>
<td colspan="2" valign="top" width="79%">
<div align="center">
<table id="table80" border="1" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><span style="font-size: large;">Specifications </span>(accuracy stated at 23<span style="font-family: Verdana;">°C ±5°C ±(% of rdg + number of digits), &lt; 60% R.H.)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Measurement Range</td>
<td bgcolor="#C0C0C0">0 Volts to 600 Volts</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Resolution</td>
<td bgcolor="#C0C0C0">0.1 Volt</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Accuracy</td>
<td bgcolor="#C0C0C0"><span style="font-family: Verdana;">±(1.0% of reading + 2 digits)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Working Frequency</td>
<td bgcolor="#C0C0C0">50/60Hz <span style="font-family: Verdana;">±6%</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Type of Measurement</td>
<td bgcolor="#C0C0C0">True Rms</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Bandwidth</td>
<td bgcolor="#C0C0C0">3200Hz</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Maximum Crest Factor</td>
<td bgcolor="#C0C0C0">3</td>
</tr>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><i>Note: meter consider null readings &lt; 2 volts</i></td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><span style="font-size: large;">General Specifications</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Sampling Rate</td>
<td bgcolor="#C0C0C0">64 point, 20ms for each sampling period</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Sampling Period</td>
<td bgcolor="#C0C0C0">1 sec, 6 sec, 30 sec, 1 min, 5 min</td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Memory Capacity</td>
<td bgcolor="#C0C0C0">1 Mbyte<br />
Life in days (depending on batteries life):<br />
5 days/1 sec; 34 days/6 sec; 170 days/30 sec; 364 days/1 min;<br />
1820 days/ 5 min</td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Computer Interface</td>
<td bgcolor="#C0C0C0">RS-232</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Operating Temperature/Humidity</td>
<td bgcolor="#C0C0C0">-20<span style="font-family: Verdana;">°C to 60°C; 0 to 100% R.H. (RS-232 connector closed)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Storage Temperature</td>
<td bgcolor="#C0C0C0">-20<span style="font-family: Verdana;">°C to 60°C; 0 to 100% R.H. (RS-232 connector closed)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Insulation</td>
<td bgcolor="#C0C0C0">class 2 (double insulation)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Protection Degree</td>
<td bgcolor="#C0C0C0">IP65 (RS-232 connector closed)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Maximum Altitude</td>
<td bgcolor="#C0C0C0">2000 meters</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td rowspan="2" valign="top" bgcolor="#C0C0C0" width="281">Reference Standards</td>
<td bgcolor="#C0C0C0">LVD: IEC/EN 61010-1 CAT III 1000V (to ground), CAT IV 600V (to ground)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0">EMC: IEC/EN 61326 (1997) +A1 (1998) +A2 (2001)</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Power Supply</td>
<td bgcolor="#C0C0C0">2 x 1.5 volt type &#8216;AA&#8217; alkaline batteries type LR6, AM3, MN1500</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Battery Life</td>
<td bgcolor="#C0C0C0">6 months</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Dimensions</td>
<td bgcolor="#C0C0C0">120mm (L) x 80mm (W) x 43mm (D)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Test Lead Length</td>
<td bgcolor="#C0C0C0">2.6 meters</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Weight</td>
<td bgcolor="#C0C0C0">500g (with internal batteries)</td>
</tr>
</tbody>
</table>
</div>
</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/ht-italia-xl423-true-rms-ac-single-phase-voltage-logger/">HT Italia XL423 True-Rms AC  Single-Phase Voltage Logger</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/ht-italia-xl423-true-rms-ac-single-phase-voltage-logger/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>