<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>TEKBOX Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/tekbox/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/tekbox/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Mon, 23 Sep 2024 03:35:29 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.9</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>TEKBOX Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/tekbox/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>TEKBOX TBL5016-2 50uH Line Impedance Stabilization Network</title>
		<link>https://rapid-tech.com.au/tekbox-tbl5016-2-50uh-line-impedance-stabilization-network/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 15 Dec 2020 04:57:46 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=17150</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2020/11/TekBox-Logo.gif"><img class="alignnone size-full wp-image-16971" src="https://rapid-tech.com.au/wp-content/uploads/2020/11/TekBox-Logo.gif" alt="" width="292" height="50" /></a></p>
<p>The TEKBOX TBL5016-2 is a Line Impedance Stabilization Network (LISN)for the measurement of line-conducted interference within the range of 9kHz to 30MHz, according to the CISPR 16-1-2 standard.</p>
<p>The device is designed for testing single phase, AC-powered equipment with <strong>supply voltages up to maximum 240V and 16A.</strong></p>
<p><strong><img class="alignnone size-full wp-image-17809" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-Download-e1620015214396.png" alt="PDF Download icon" width="51" height="60" /></strong>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/12/TEKBOX-TBL5016-2-User-Manual.pdf" rel="noopener">TEKBOX TBL5016-2 User Manual</a></span></p>
<p>The post <a href="https://rapid-tech.com.au/tekbox-tbl5016-2-50uh-line-impedance-stabilization-network/">TEKBOX TBL5016-2 50uH Line Impedance Stabilization Network</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>With the TEKBOX TBL5016-2 50uH Line Impedance Stabilization Network (LISN) conducted noise can be measured on the phase and on the neutral conductor. The TBL5016-2 is equipped with a switchable limiter/attenuator and an artificial hand connection.</p>
<p>The device is available with <span style="font-size: 110%;"><strong>country-specific DUT output connectors.</strong></span></p>
<h4>SPECIFICATIONS</h4>
<div class="section__content">
<ul>
<li>Frequency range: 9 kHz to 30 MHz</li>
<li>Impedance: 50 Ω ║ (50 µH + 5 Ω)</li>
<li>Artificial hand: 220 pF + 511 Ω</li>
<li>Switchable PE: 50 Ω ║ 50 µH</li>
<li>Limiter / attenuator: 150 kHz to 30 MHz; 10 dB</li>
<li>Air core inductors</li>
<li>Line voltage: max. 240V / 50 – 60 Hz, CAT ‖‖</li>
<li>Max. current: 16A @ 23°C</li>
<li>DUT socket: country specific</li>
<li>Measurement connector: 50 Ω BNC</li>
<li>Power connector: IEC 60320 C19</li>
<li>Operating Temperature Range: +5°C … + 40°C; 5% to 80% RH</li>
<li>Safety: Safety Class I, IEC 1010-01</li>
</ul>
</div>
<p>The post <a href="https://rapid-tech.com.au/tekbox-tbl5016-2-50uh-line-impedance-stabilization-network/">TEKBOX TBL5016-2 50uH Line Impedance Stabilization Network</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>TEKBOX TBPS01 EMC Near Field Probe Set</title>
		<link>https://rapid-tech.com.au/tekbox-tbps01-emc-near-field-probe-set/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Mon, 23 Nov 2020 05:11:56 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=17021</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2020/11/TekBox-Logo.gif"><img class="alignnone size-full wp-image-16971" src="https://rapid-tech.com.au/wp-content/uploads/2020/11/TekBox-Logo.gif" alt="" width="292" height="50" /></a></p>
<p>The TBPS01 EMC near field probes H20, H10, H5 and E5 are magnetic field (H) and electric field (E) probes for radiated emissions EMC pre-compliance measurements. The probes are used in the near field of sources of electromagnetic radiation.</p>
<p>The probes act similar as wide bandwidth antennas, picking up radiated emissions from components, PCB traces, housing openings or gaps and from any other parts that could be emitting RF. The probes are usually connected to a spectrum analyzer. Scanning the probe over the surface of a PCB assembly or housing quickly identifies locations which emit electromagnetic radiation. By changing to a probe with smaller size, the origination of the emissions can be further narrowed down.</p>
<ul>
<li>TBPS01 EMC Near Field Probe Set</li>
<li>Slim design for good access in between tightly spaced components</li>
<li>Shielded loops to avoid picking up common mode noise; insensitive to the human hand</li>
<li>Frequency range: 3GHz, though they can be used well beyond</li>
<li>SMB connectors to avoid twisting the RF cable when scanning DUTs</li>
</ul>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/11/TBPS01-Datasheet.pdf" rel="noopener noreferrer">TBPS01 Datasheet</a></span></h4>
<p>The post <a href="https://rapid-tech.com.au/tekbox-tbps01-emc-near-field-probe-set/">TEKBOX TBPS01 EMC Near Field Probe Set</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The TEKBOX TBPS01 EMC Near Field Probe Set consists of H20, H10, H5 and E5 are magnetic field (H) and electric field (E) probes for radiated emissions EMC pre- compliance measurements. The probes are used in the near field of sources of electromagnetic radiation. They serve to locate and identify potential sources of interference within the building blocks of electronic assemblies.</p>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2020/11/TekBox-TBPS01-case.jpg"><img fetchpriority="high" decoding="async" class="size-medium wp-image-17024 aligncenter" src="https://rapid-tech.com.au/wp-content/uploads/2020/11/TekBox-TBPS01-case-296x300.jpg" alt="" width="296" height="300" srcset="https://rapid-tech.com.au/wp-content/uploads/2020/11/TekBox-TBPS01-case-296x300.jpg 296w, https://rapid-tech.com.au/wp-content/uploads/2020/11/TekBox-TBPS01-case-300x304.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2020/11/TekBox-TBPS01-case-100x100.jpg 100w, https://rapid-tech.com.au/wp-content/uploads/2020/11/TekBox-TBPS01-case.jpg 586w" sizes="(max-width: 296px) 100vw, 296px" /></a></p>
<p>The probes act similar as wide bandwidth antennas, picking up radiated emissions from components, PCB traces, housing openings or gaps and from any other parts that could be emitting RF. The probes are usually connected to a spectrum analyser. Scanning the probe over the surface of a PCB assembly or housing quickly identifies locations which emit electromagnetic radiation. By changing to a probe with smaller size, the origination of the emissions can be further narrowed down.</p>
<p>Additional applications are RF immunity tests by feeding a RF signal into the probe and radiating it into potentially susceptible circuit sections: Furthermore the probes can be used in the field of repair or debugging to track down issues in RF signal chains by contactless measurement of RF signal levels.</p>
<p>One more application is non- invasive measurement of RF building blocks such as modulators or oscillators. Frequency, phase noise and spectral components can be measured in conjunction with a low noise preamplifier. The TBWA2/20dB and TBWA2/40db wideband amplifiers are connected between EMC probe and Spectrum Analyzer to increase the dynamic range of the measurements.</p>
<p>The post <a href="https://rapid-tech.com.au/tekbox-tbps01-emc-near-field-probe-set/">TEKBOX TBPS01 EMC Near Field Probe Set</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>TEKBOX TBOH01 5UH Line Impedance Stablisation Network – CISPR 25</title>
		<link>https://rapid-tech.com.au/tekbox-tboh01-5uh-line-impedance-stablisation-network-cispr-25/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Thu, 19 Nov 2020 06:52:07 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=16976</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2020/11/TekBox-Logo.gif"><img class="alignnone size-full wp-image-16971" src="https://rapid-tech.com.au/wp-content/uploads/2020/11/TekBox-Logo.gif" alt="" width="292" height="50" /></a></p>
<p>The TBOH01 5uH LISN is a device required to setup conducted noise measurements of DC-powered devices.</p>
<p>It is designed to be used for EMC pre-testing in the frequency range of 150kHz to 110 MHz.</p>
<p>The LISN is inserted into the supply line of the DUT (Device Under Test). Conducted noise which is present at the supply terminals of the DUT can be measured at the BNC connector using a spectrum analyzer or a measurement receiver.</p>
<p>The source (supply) terminal and the DUT terminal are decoupled by a 5µH inductor.</p>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><strong><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/11/TBOH01-Users-Manual.pdf" rel="noopener noreferrer">TBOH01 Users Manual</a></strong></span></h4>
<p>The post <a href="https://rapid-tech.com.au/tekbox-tboh01-5uh-line-impedance-stablisation-network-cispr-25/">TEKBOX TBOH01 5UH Line Impedance Stablisation Network – CISPR 25</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>TEKBOX TBOH01 5UH Line Impedance Stablisation Network</h3>
<p>The Tekbox TBOH01 5µH LISN is a device required to setup conducted noise measurements of DC-powered devices.</p>
<p>It is designed to be used for EMC pre-testing in the frequency range of 150kHz to 110 MHz according to the CISPR-25 standard, ISO 7637-2, ISO11452-2/4/5 and with limitations DO-160/ED-14G.</p>
<p>The LISN is inserted into the supply line of the DUT (Device Under Test). Conducted noise which is present at the supply terminals of the DUT can be measured at the BNC connector using a spectrum analyzer or a measurement receiver. The source (supply) terminal and the DUT terminal are decoupled by a 5µH inductor.</p>
<h4>Tekbox TBOH01 Specification</h4>
<div class="section__content">
<ul>
<li>Frequency range: 100kHz – 110MHz (1GHz, see picture 4 in the manual)</li>
<li>DC Resistance: 40 mΩ</li>
<li>Maximum current: 10A</li>
<li>Nominal operating voltage range: 0 – 60V DC *</li>
</ul>
<p><strong>* T<em>he operating voltage range is limited to 60V DC for safety reasons. Though the component rating of the LISN is ≥ 200V, the positive supply voltage could accidentally be connected to the negative terminal of the LISN and thereby to the LISN housing. Under this circumstance, a DC voltage &gt; 60V  could cause a lethal electric shock when touching the housing.</em></strong></p>
</div>
<p>The post <a href="https://rapid-tech.com.au/tekbox-tboh01-5uh-line-impedance-stablisation-network-cispr-25/">TEKBOX TBOH01 5UH Line Impedance Stablisation Network – CISPR 25</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>TEKBOX TBLC08 5µH AC Line Impedance Stabilisation Network 8A</title>
		<link>https://rapid-tech.com.au/tekbox-tblc08-5%c2%b5h-ac-line-impedance-stabilisation-network-8a/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Thu, 19 Nov 2020 06:12:53 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=16970</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2020/11/TekBox-Logo.gif"><img class="alignnone size-full wp-image-16971" src="https://rapid-tech.com.au/wp-content/uploads/2020/11/TekBox-Logo.gif" alt="" width="292" height="50" /></a></p>
<p>The TEKBOX TBLC08 50uH LISN is a Line Impedance Stabilization Network for the measurement of line-conducted interference within the range of 9kHz to 30MHz, according to the CISPR16 standard.</p>
<p>The device is designed for testing single phase, AC-powered equipment with supply voltages up to maximum 240V.</p>
<p>Conducted noise can be measured on the phase and on the neutral conductor.</p>
<p>The TBLC08 is equipped with a switchable limiter/attenuator and an artificial hand connection.</p>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><strong><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/11/TBLC08-Users-Manual.pdf" rel="noopener noreferrer">Tekbox TBLC08 Users Manual</a></strong></span></p>
<p>The post <a href="https://rapid-tech.com.au/tekbox-tblc08-5%c2%b5h-ac-line-impedance-stabilisation-network-8a/">TEKBOX TBLC08 5µH AC Line Impedance Stabilisation Network 8A</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The TBLC08 is a Line Impedance Stabilization Network (LISN) for the measurement of line-conducted interference within the range of 9kHz to 30MHz, according to the CISPR16 standard. The device is designed for testing single phase, AC-powered equipment with supply voltages up to maximum 260V.</p>
<p>Conducted noise can be measured on the phase and on the neutral conductor. The TBLC08 is equipped with a switchable limiter/attenuator and an artificial hand connection.</p>
<p>Full compliance measurement of AC mains supplied products requires a high end set up consisting of an anechoic or screened chamber, a measurement receiver that complies with the requirements of CISPR 16, a 50µH LISN and a suitable table for the measurement setup.</p>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2020/11/Basic-LISN-Setup.jpg"><img decoding="async" class="aligncenter wp-image-16974" src="https://rapid-tech.com.au/wp-content/uploads/2020/11/Basic-LISN-Setup-300x120.jpg" alt="" width="600" height="239" srcset="https://rapid-tech.com.au/wp-content/uploads/2020/11/Basic-LISN-Setup-300x120.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2020/11/Basic-LISN-Setup-600x239.jpg 600w, https://rapid-tech.com.au/wp-content/uploads/2020/11/Basic-LISN-Setup-1024x409.jpg 1024w, https://rapid-tech.com.au/wp-content/uploads/2020/11/Basic-LISN-Setup-768x306.jpg 768w, https://rapid-tech.com.au/wp-content/uploads/2020/11/Basic-LISN-Setup.jpg 1030w" sizes="(max-width: 600px) 100vw, 600px" /></a></p>
<h4>TEKBOX TBLC08 SPECIFICATIONS</h4>
<div class="section__content">
<ul>
<li>Frequency range: 9 kHz to 30 MHz</li>
<li>Impedance: 50 Ω ║ (50 µH + 5 Ω)</li>
<li>Artificial hand: 220 pF + 511 Ω</li>
<li>Switchable PE: 50 Ω ║ 50 µH</li>
<li>Limiter / attenuator: 150 kHz to 30 MHz; 10 dB</li>
<li>Air core inductors</li>
<li>Line voltage: max. 240V / 50 – 60 Hz, CAT ‖</li>
<li>Max. current: 8A @ 23°C</li>
<li>DUT socket: country specific</li>
<li>Measurement connector: 50 Ω BNC</li>
<li>Power connector: IEC 60320 C13</li>
<li>Operating Temperature Range: +5°C … + 40°C; 5% to 80% RH</li>
<li>Safety: Safety Class I, IEC 1010-01</li>
</ul>
</div>
<p>The post <a href="https://rapid-tech.com.au/tekbox-tblc08-5%c2%b5h-ac-line-impedance-stabilisation-network-8a/">TEKBOX TBLC08 5µH AC Line Impedance Stabilisation Network 8A</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
