Benefits and Key Features
Universal LCR meter
- Fast, accurate and versatile (Fast: ≤ 15 ms, Medium: ≤ 100 ms, Slow: ≤ 500 ms)
- Selectable frequency range (4 Hz to 10 MHz)
- Test signals for all requirements (100 mV to 10 V – up to 200 mA)
- DC bias (Voltage of up to 10 V)
- Measurement functions
- Data logging function (up to 10 sample/s)
Options for advanced applications
- R&S LCX-K106 advanced analysis functions
- R&S LCX-K107 digital I/O ports and binning function
- R&S LCX-K108 extended bias functions
- R&S LCX-K201/-K210 frequency upgrade to 1 MHz/10 MHz
Easy operation
- High-resolution touchscreen
- Graphical representation of measurements
- Save and recall instrument settings
Test fixtures
- R&S LCX-Z1 test fixture for axial/radial lead type devices
- R&S LCX-Z2 Kelvin clip lead
- R&S LCX-Z3 test fixture for SMD components
- R&S LCX-Z4 test tweezers for SMD components
- R&S LCX-Z5 transformer test cables
- R&S LCX-Z11 BNC extension
R&S®LCX100 LCR meters cover a frequency range of 4 Hz to 300 kHz. The R&S®LCX200 has an upper frequency limit of 500 kHz and can be extended to 1 MHz or 10 MHz using software options when needed.
The R&S®LCX200 offers an upper frequency limit of 500 kHz and can be extended to 1 MHz or 10 MHz using software options when needed.
DC measurements are available on all instruments. Most applications can be covered with voltages as high as 10 V generated internally. It is also possible to apply bias voltages of up to 40 V externally.
All measured values are recorded up to 10 times per second using the fast logging function.
The advanced analysis function allows you to perform dynamic impedance measurements. These sweep measurements determine the impedance values for a series of frequency values or other parameters.
Digital I/O ports can be used to trigger and control measurements externally. Using the binning function, the measured components can be sorted by their values into eight categories.
With the large capacitive touchscreen, you can operate the instruments in a modern and intuitive way and visualize the results of your measurements graphically.
Remote controllability and rack installation make the R&S®LCX ideal for system applications.
Ideal for use in labs and test systems
- Tailored for use in labs and system racks
- Full remote capabilities
- Advanced instrument design: compact form factor, quiet operation
Key facts
Features |
R&S®LCX100 |
R&S®LCX200 |
Test signal frequency |
DC, 4 Hz to 300 kHz |
DC, 4 Hz to 10 MHz (option) |
Test signal voltage |
100 mV to 10 V |
< 1 MHz: 100 mV to 10 V, > 1 MHz: 100 mV to 2 V |
DC bias voltage (internal) |
0 V to +10 V |
|
DC bias current (internal) |
0 mA to 200 mA |
|
External DC bias voltage, input |
0 V to +40 V |
|
Source impedance |
100 Ω, 10 Ω |
|
Measurement range |
100 mΩ to 100 MΩ |
|
Basic accuracy for impedance measurements |
0.05 % |