<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Multifunction Installation Tester Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/product-tag/multifunction-installation-tester/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/product-tag/multifunction-installation-tester/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Thu, 25 Jun 2026 02:56:16 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>Multifunction Installation Tester Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/product-tag/multifunction-installation-tester/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Metrel MI3136 Kit InstalTest COMBO XC — Advanced Set with Bag &#038; Accessories</title>
		<link>https://rapid-tech.com.au/metrel-mi3136-kit-instaltest-combo-xc-advanced-set/</link>
					<comments>https://rapid-tech.com.au/metrel-mi3136-kit-instaltest-combo-xc-advanced-set/#respond</comments>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Wed, 24 Jun 2026 02:50:12 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=1119364</guid>

					<description><![CDATA[<h3><img class="alignnone size-medium wp-image-7625" src="https://mymeter.com.au/wp-content/uploads/2022/04/Metrel-Logo-L-300x78.jpeg" alt="Metrel-Logo" width="300" height="78" /></h3>
<p><a target="_blank" href="https://mymeter.com.au/product/metrel-mi3136-kit-instaltest-combo-xc-advanced-set/" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="439:1-439:479;25862-26340">The Metrel MI3136 Kit delivers everything in the standard MI3136 InstalTest COMBO XC — 12 tests, AS/NZS 3017 Pass/Fail limits, touch-screen operation, and Metrel Cloud reporting — packaged with five essential field accessories: a large padded carry bag, remote probe, resistor box, 4 m trailing lead, and non-contact voltage detector. It's the complete, ready-to-deploy installation testing solution for Australian electricians who want to step on-site and get straight to work.</p>
<h4><img class="alignnone size-full wp-image-6653" src="https://mymeter.com.au/wp-content/uploads/2018/10/PDF-blue.png" alt="PDF download" width="43" height="54" /> <a target="_blank" href="https://mymeter.com.au/wp-content/uploads/2026/06/Single_2026_MI-3136-EurotestCOMBO-XC_Ang.pdf" rel="noopener">Metrel MI3136 Datasheet</a></h4>
<p>The post <a href="https://rapid-tech.com.au/metrel-mi3136-kit-instaltest-combo-xc-advanced-set/">Metrel MI3136 Kit InstalTest COMBO XC — Advanced Set with Bag &#038; Accessories</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="447:1-447:47;26402-26448">The Complete Kit. No Extras to Chase Down.</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="449:1-449:301;26450-26750">The MI3136 is already a serious instrument — 12 tests, a modern touch screen, AS/NZS 3017 preset limits, and Metrel Cloud reporting built in from day one. But when you order the standard unit, you&#8217;ll need to source a carry bag and a few essential accessories separately before it&#8217;s fully field-ready.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="451:1-451:351;26752-27102">The MI3136 Kit solves that in one order. Everything ships together — the instrument plus the five accessories that experienced electricians reach for first — at a combined price that&#8217;s noticeably lower than buying them individually. For contractors equipping a new van, a new employee, or replacing a worn-out kit, this is the straightforward option.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="455:1-455:50;27109-27158">What&#8217;s in the Kit — and Why Each Item Matters</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="457:1-457:43;27160-27202"><strong>A1551 Large Padded Carry Bag for XC/XD</strong></p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="459:1-459:435;27204-27638">The MI3136 doesn&#8217;t include a carry bag in its standard set, and an instrument costing close to $2,000 deserves proper protection in transit. The A1551 is sized for the MI3136 and its full accessory complement — probes, leads, clips, and adapters all stored together, protected, and organised. Whether it&#8217;s going in a van, onto a work site elevator, or into a panel room, a padded bag is not a luxury — it&#8217;s practical asset protection.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="461:1-461:33;27640-27672"><strong>A1401 Remote Probe for XC/XD</strong></p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="463:1-463:414;27674-28087">Think of this as the equivalent of a Fluke TP165x for the Metrel system. The A1401 Remote Probe extends your reach into distribution boards, ceiling-mounted outlets, back-of-panel terminals, and tight cabinet spaces where your standard test probes physically won&#8217;t fit or can&#8217;t be held safely. On any commercial or industrial site with recessed switchgear, this probe earns its place in the first hour on the job.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="465:1-465:23;28089-28111"><strong>A1195 Resistor Box</strong></p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="467:1-467:373;28113-28485">The Resistor Box enables verification of your RCD test results and continuity measurements using a known reference resistance — important for confidence-checking your instrument&#8217;s readings when fault-finding produces unexpected results. It&#8217;s also relevant for demonstrating traceability when your test reports are scrutinised by a building inspector or compliance auditor.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="469:1-469:36;28487-28522"><strong>A1012 Trailing Lead — 4 m Green</strong></p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="471:1-471:465;28524-28988">While the MI3136&#8217;s socket test function works without a trailing lead for standard outlet verification, a 4 m green trailing lead is essential for earthing continuity tests back to a known earth reference — particularly on dead installation testing where the socket circuit isn&#8217;t yet energised. It also extends your reach for PE bonding measurements across larger floor areas. Green is the correct colour coding for earth connections under Australian wiring rules.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="473:1-473:40;28990-29029"><strong>MD-106 Non-Contact Voltage Detector</strong></p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="475:1-475:372;29031-29402">Before you plug your probe into anything, you need to know whether it&#8217;s live. The MD-106 is a simple, reliable non-contact voltage detector that adds a critical layer of personal safety to every site visit. It&#8217;s the first thing you pick up and the last thing you put down — and having it paired with your installation tester from day one reinforces safe working practice.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="485:1-485:35;29773-29807">Everything Else Stays the Same</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="487:1-487:70;29809-29878">The instrument in the MI3136 Kit is identical to the standard MI3136:</p>
<ul class="[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3" data-sourcepos="489:1-498:50;29880-30459">
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="489:1-489:76;29880-29955">12 installation tests covering every mandatory function under AS/NZS 3017</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="490:1-490:61;29956-30016">4.3-inch colour TFT touch screen with Pass/Fail evaluation</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="491:1-491:41;30017-30057">Socket testing without a trailing lead</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="492:1-492:58;30058-30115">Auto-Sequences (up to 6 tests per push-button sequence)</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="493:1-493:60;30116-30175">Real-time monitoring of all three voltages simultaneously</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="494:1-494:63;30176-30238">Built-in fuse tables for automatic loop impedance evaluation</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="495:1-495:46;30239-30284">Bluetooth + Wi-Fi + USB Type-C connectivity</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="496:1-496:60;30285-30344">Metrel Cloud and Metrel ES Manager BASIC licence included</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="497:1-497:65;30345-30409">Optional A-1532XA EVSE Adapter for EV charging station testing</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="498:1-498:50;30410-30459">600 V CAT III / 300 V CAT IV overvoltage rating</li>
</ul>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="500:1-500:76;30461-30536">For full technical specifications, see the <a href="#" class="underline underline underline-offset-2 decoration-1 decoration-current/40 hover:decoration-current focus:decoration-current">Metrel MI3136 product page</a>.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h2 class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold" data-sourcepos="504:1-504:28;30543-30570">Technical Specifications</h2>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="506:1-506:141;30572-30712"><em>Full instrument specifications are identical to the MI3136 standard set. See the MI3136 product page for the complete specification table.</em></p>
<div class="overflow-x-auto w-full px-2 mb-6" data-sourcepos="508:1-515:111;30714-31429">
<table class="min-w-full border-collapse text-sm leading-[1.7] whitespace-normal">
<thead class="text-left">
<tr>
<th class="text-text-100 border-b-0.5 border-[hsl(var(--border-300)/0.6)] py-2 pr-4 align-top font-bold" scope="col">Kit Component</th>
<th class="text-text-100 border-b-0.5 border-[hsl(var(--border-300)/0.6)] py-2 pr-4 align-top font-bold" scope="col">Model</th>
<th class="text-text-100 border-b-0.5 border-[hsl(var(--border-300)/0.6)] py-2 pr-4 align-top font-bold" scope="col">Purpose</th>
</tr>
</thead>
<tbody>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Instrument</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">MI3136 InstalTest COMBO XC</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">12-function installation tester, AS/NZS 3017</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Carry Bag</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">A1551 Large Padded Carry Bag</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Protected transport and storage for instrument and accessories</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Remote Probe</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">A1401 Remote Probe for XC/XD</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Access to recessed outlets, panel boards, and cabinet terminals</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Resistor Box</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">A1195 Resistor Box</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Reference resistance for RCD and continuity result verification</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Trailing Lead</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">A1012 Trailing Lead — 4 m Green</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Earth continuity testing and PE bonding measurement extension</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Voltage Detector</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">MD-106 Non-Contact Voltage Detector</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Live/dead identification before probe contact</td>
</tr>
</tbody>
</table>
</div>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h2 class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold" data-sourcepos="519:1-519:21;31436-31456">AEO Answer Blocks</h2>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="521:1-521:72;31458-31529">What&#8217;s the difference between the Metrel MI3136 and the MI3136 Kit?</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="523:1-523:422;31531-31952">The MI3136 Kit contains the same MI3136 InstalTest COMBO XC instrument as the standard set, plus five field accessories: an A1551 Large Padded Carry Bag, an A1401 Remote Probe, an A1195 Resistor Box, an A1012 4 m Green Trailing Lead, and an MD-106 Non-Contact Voltage Detector. The standard MI3136 does not include a carry bag or these accessories. The Kit is priced at $2,590 + GST vs $1,990 + GST for the standard unit.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="527:1-527:71;31959-32029">Is the MI3136 Kit better value than buying accessories separately?</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="529:1-529:283;32031-32313">Yes. The MI3136 Kit is priced below the total cost of the MI3136 plus the five included accessories purchased individually. The combined saving is approximately $166 + GST, with the added convenience of a single order and everything arriving together ready for immediate deployment.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="533:1-533:45;32320-32364">What is the A1401 Remote Probe used for?</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="535:1-535:429;32366-32794">The A1401 Remote Probe is a handheld probe that extends the MI3136&#8217;s reach into locations that standard probes can&#8217;t easily access — distribution board terminals, recessed socket outlets, ceiling-mounted GPOs, and equipment cabinet connection points. It functions similarly to the Fluke TP165x and is particularly useful on commercial and industrial installations where testing at panel-mounted connections is part of the scope.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="539:1-539:81;32801-32881">Why does the MI3136 need a trailing lead if it can test sockets without one?</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="541:1-541:416;32883-33298">The MI3136&#8217;s no-trailing-lead socket test covers outlet verification — earth continuity, polarity, and correct connections at the socket face. A trailing lead (A1012) is still needed for dead installation testing (where circuits aren&#8217;t yet energised), earth continuity measurements back to a reference point, and PE bonding verification across longer distances. The 4 m green lead in the kit covers these scenarios.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="567:1-568:577;34970-35614">
<p>The post <a href="https://rapid-tech.com.au/metrel-mi3136-kit-instaltest-combo-xc-advanced-set/">Metrel MI3136 Kit InstalTest COMBO XC — Advanced Set with Bag &#038; Accessories</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/metrel-mi3136-kit-instaltest-combo-xc-advanced-set/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Title: Metrel MI3136 InstalTest COMBO XC — Multifunction Installation Tester Australia</title>
		<link>https://rapid-tech.com.au/metrel-mi3136-instaltest-combo-xc/</link>
					<comments>https://rapid-tech.com.au/metrel-mi3136-instaltest-combo-xc/#respond</comments>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Tue, 23 Jun 2026 23:22:12 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=1119359</guid>

					<description><![CDATA[<h3><img class="alignnone size-medium wp-image-7625" src="https://mymeter.com.au/wp-content/uploads/2022/04/Metrel-Logo-L-300x78.jpeg" alt="Metrel-Logo" width="300" height="78" /></h3>
<p><a target="_blank" href="https://mymeter.com.au/product/metrel-mi3136-instaltest-combo-xc/" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="17:1-17:554;279-832">The Metrel MI3136 InstalTest COMBO XC is a next-generation touch-screen multifunction installation tester purpose-built for Australian electricians. Replacing five separate instruments with 12 tests in a single compact unit, it delivers Pass/Fail results to AS/NZS 3017, tests sockets in seconds without a trailing lead, and stores job records for professional PDF reporting via Metrel Cloud. The ideal upgrade for licensed electricians, inspectors, and maintenance professionals who need compliant, fast, and accurate installation verification on-site.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="19:1-19:102;834-935">Carry bag not included — see the MI3136 Kit for a bundled accessory option.</p>
<h4><img class="alignnone size-full wp-image-6653" src="https://mymeter.com.au/wp-content/uploads/2018/10/PDF-blue.png" alt="PDF download" width="43" height="54" /> <a target="_blank" href="https://mymeter.com.au/wp-content/uploads/2026/06/Single_2026_MI-3136-EurotestCOMBO-XC_Ang.pdf" rel="noopener">Metrel MI3136 Datasheet</a></h4>
<p>The post <a href="https://rapid-tech.com.au/metrel-mi3136-instaltest-combo-xc/">Title: Metrel MI3136 InstalTest COMBO XC — Multifunction Installation Tester Australia</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="25:1-25:51;978-1028">Five Instruments Retired. One Tester Steps Up.</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="27:1-27:402;1030-1431">Every licensed electrician knows the problem. You show up to a new build or a periodic inspection and you&#8217;re lugging a multimeter, an insulation tester, an RCD tester, a loop impedance tester, and a phase sequence tester — all needing their own cables, batteries, and firmware. Then come the reports. Handwritten notes, manually assembled spreadsheets, chasing down job numbers at the end of the week.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="29:1-29:442;1433-1874">The Metrel MI3136 InstalTest COMBO XC was designed to fix exactly that. It replaces those five instruments with a single touch-screen unit that runs 12 distinct tests, stores your results, and produces professional PDF reports — ready to hand to a client or file for compliance records. This is what it looks like when Metrel takes a decade of installation testing experience and rebuilds it from the ground up for today&#8217;s electrical trades.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="33:1-33:50;1881-1930">Built for AS/NZS 3017 Compliance from Day One</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="35:1-35:457;1932-2388">Australian installation testing isn&#8217;t optional — and neither is accuracy. The MI3136 has Pass/Fail limits preset to AS/NZS 3017, so there&#8217;s no second-guessing whether a loop impedance result actually passes or whether you need to cross-reference a fuse table manually. The built-in fuse tables handle that evaluation automatically based on the selected area group. Built-in help screens give on-site guidance when you need it, without pulling out a manual.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="37:1-37:211;2390-2600">For initial verification and periodic inspection of low-voltage TT and TN systems — the bread and butter of residential and commercial electrical work under AS/NZS 3000 — the MI3136 covers every mandatory test:</p>
<ul class="[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3" data-sourcepos="39:1-48:22;2602-3276">
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="39:1-39:110;2602-2711"><strong>Continuity</strong> at 200 mA (for earth resistance and equipotential bonding) and 7 mA (for general resistance)</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="40:1-40:78;2712-2789"><strong>Insulation resistance</strong> at 50V, 100V, 250V, 500V, and 1000V test voltages</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="41:1-41:109;2790-2898"><strong>RCD testing</strong> — trip time and trip current for 10 mA through 1000 mA, with 0° and 180° starting polarity</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="42:1-42:82;2899-2980"><strong>Fault loop impedance</strong> (L-PE, L-L, L-N) and prospective short-circuit current</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="43:1-43:21;2981-3001"><strong>Line impedance</strong></li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="44:1-44:34;3002-3035"><strong>Phase sequence and rotation</strong></li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="45:1-45:115;3036-3150"><strong>Live socket testing</strong> — earth continuity, polarity, and correct connections, Pass/Fail without a trailing lead</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="46:1-46:44;3151-3194"><strong>Earth resistance</strong> (3-wire measurement)</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="47:1-47:60;3195-3254"><strong>Voltage and frequency</strong> measurement to 550 V / 499.9 Hz</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="48:1-48:22;3255-3276"><strong>Contact voltage</strong></li>
</ul>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="50:1-50:207;3278-3484">All results display on a 4.3-inch colour TFT touch screen with real-time monitoring of all three voltages simultaneously. Automatic polarity reversal on continuity keeps testing moving without manual reset.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="54:1-54:51;3491-3541">Sockets in Seconds — No Trailing Lead Required</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="56:1-56:362;3543-3904">One of the most time-consuming aspects of socket testing on larger jobs is running trailing leads across a floor or down a hallway for every outlet. The MI3136 eliminates that step entirely. Its socket test function checks earth continuity, polarity, and correct connections in a single push-button operation — directly from the socket, no trailing lead needed.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="58:1-58:439;3906-4344">Combine that with Auto-Sequences that chain up to six individual tests into one push-button sequence, and high-volume socket testing on large residential or commercial installations becomes significantly faster. Auto-sequences can be configured for standard installation verification workflows, or customised for specific job types — RCD-heavy commercial work, new subdivision wiring, or periodic inspections under a specific test regime.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="62:1-62:32;4351-4382">Record, Report, and Move On</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="64:1-64:384;4384-4767">Paper-based test records are a liability. A missed entry, an illegible reading, or a misfiled result creates compliance exposure you don&#8217;t want. The MI3136 stores test results internally and connects via Wi-Fi and Bluetooth to Metrel Cloud — allowing you to manage test structures, upload results from the field, and generate professional PDF reports without returning to a PC first.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="66:1-66:351;4769-5119">Back at the office or workshop, Metrel ES Manager (BASIC licence included) lets you build test structures, manage customer job histories, and produce polished reports for clients and regulators. For contractors managing multiple jobs simultaneously, the Metrel Cloud App extends this to mobile devices — giving you live visibility across active jobs.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="70:1-70:38;5126-5163">EV Charging Station Testing Ready</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="72:1-72:489;5165-5653">With EV charging infrastructure rolling out across Australian residential, commercial, and light-industrial sites, the capacity to test Mode 3 EVSE charging stations is increasingly part of an electrician&#8217;s scope of work. The MI3136 supports the optional A-1532XA EVSE Adapter, which turns the tester into a dedicated EVSE verification tool for Type 2 charging stations — performing electrical safety and functional testing from a single push button and generating compliant test reports.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="74:1-74:216;5655-5870">Note: The A-1532XA adapter is available separately. For field technicians working on EV charging installation projects, this represents a practical capability extension without investing in a standalone EVSE tester.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="78:1-78:38;5877-5914">Remote Probe for Difficult Access</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="80:1-80:412;5916-6327">Like the Fluke TP165x, the optional A1401 Remote Probe allows the MI3136 to reach sockets and test points in panel boards, cabinets, and ceiling-mounted outlets where the standard probe set can&#8217;t reach comfortably. This is particularly useful on large commercial or industrial sites where distribution board testing is part of the scope. The Remote Probe is included in the MI3136 Kit — or available separately.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="84:1-84:43;6334-6376">What the MI3136 Is (and What It Isn&#8217;t)</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="86:1-86:309;6378-6686">The MI3136 is Metrel&#8217;s newest mid-range installation tester — the direct replacement for the MI3152, which is now at end of stock. It covers every mandatory installation test that Australian electricians need to perform under AS/NZS 3017, plus EV charging station verification with the optional EVSE adapter.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="88:1-88:547;6688-7234">It&#8217;s worth being clear about one trade-off: the MI3136 does not support the extended adapter ecosystem available on the MI3155 EurotestXD. If your scope of work regularly includes luxmeter measurements (emergency lighting inspections), cable tracing with the R10K receiver, or current clamp-based earth resistance testing, the MI3155 remains the appropriate choice. The MI3136 is purpose-designed for installation verification — it does that job thoroughly, efficiently, and with professional reporting built in, at a more accessible price point.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="92:1-92:30;7241-7270">In the Box — Standard Set</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="94:1-94:57;7272-7328">The MI3136 ships with a complete standard accessory set:</p>
<ul class="[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3" data-sourcepos="96:1-103:34;7330-7597">
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="96:1-96:39;7330-7368">Test probes × 3 (Brown, Blue, Green)</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="97:1-97:43;7369-7411">Crocodile clips × 3 (Brown, Blue, Green)</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="98:1-98:33;7412-7444">Test cable, BRN/GRN/BLU, 1.5 m</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="99:1-99:20;7445-7464">Test cable, 1.5 m</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="100:1-100:19;7465-7483">USB Type-C cable</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="101:1-101:54;7484-7537">Rechargeable Li-ion battery pack (7.2 V / 5200 mAh)</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="102:1-102:26;7538-7563">Calibration certificate</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="103:1-103:34;7564-7597">Metrel ES Manager BASIC Licence</li>
</ul>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="105:1-105:228;7599-7826"><strong>Note:</strong> The MI3136 standard set does not include a carry bag. For a complete field-ready kit with padded bag, remote probe, resistor box, trailing lead, and non-contact voltage detector, see the <strong>MI3136 Kit</strong> ($2,590 + GST).</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h2 class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold" data-sourcepos="109:1-109:28;7833-7860">Technical Specifications</h2>
<div class="overflow-x-auto w-full px-2 mb-6" data-sourcepos="111:1-133:179;7862-11295">
<table class="min-w-full border-collapse text-sm leading-[1.7] whitespace-normal">
<thead class="text-left">
<tr>
<th class="text-text-100 border-b-0.5 border-[hsl(var(--border-300)/0.6)] py-2 pr-4 align-top font-bold" scope="col">Specification</th>
<th class="text-text-100 border-b-0.5 border-[hsl(var(--border-300)/0.6)] py-2 pr-4 align-top font-bold" scope="col">Value</th>
<th class="text-text-100 border-b-0.5 border-[hsl(var(--border-300)/0.6)] py-2 pr-4 align-top font-bold" scope="col">Why It Matters</th>
</tr>
</thead>
<tbody>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Test Functions</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">12 (continuity, insulation resistance, RCD trip time &amp; current, loop/line impedance, phase sequence, socket test, earth resistance, voltage, frequency, contact voltage)</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Replaces five separate instruments; covers every mandatory test under AS/NZS 3017</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Continuity — 200 mA</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">0.00 Ω to 1999 Ω, ±(3% + 3 digits) to ±(5%)</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">AS/NZS 3017 requires 200 mA for earth and equipotential bonding verification</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Continuity — 7 mA</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">0.0 Ω to 1999 Ω, ±(5% + 3 digits)</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">General resistance measurement without the arc risk of higher current at live terminations</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Insulation Resistance</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">50V / 100V / 250V / 500V / 1000V test voltages; range to 200 MΩ (500V) and indicative to 999 MΩ (1000V)</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Full insulation test range for both LV and medium-voltage-adjacent applications</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>RCD Testing</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">10 mA to 1000 mA; trip time 0 – 10.00 s; ramp current test; 0° and 180° starting polarity</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Covers general-purpose, Type A, and high-sensitivity RCDs across residential and commercial installations</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Fault Loop Impedance (Zloop L-PE)</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">0.00 Ω to 9.99 kΩ, ±(3% + 3 digits) at low range</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Required for prospective fault current calculation and AS/NZS 3017 compliance verification</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Line Impedance (Zline L-L, L-N)</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">0.00 Ω to 9.99 kΩ</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Determines prospective short-circuit current at the point of supply</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Voltage Measurement</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">0 – 550 V, ±(2% + 2 digits)</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Covers 230 V single-phase and 415 V three-phase Australian supply systems</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Frequency</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">14.0 – 499.9 Hz, ±(0.2% + 1 digit)</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">50 Hz nominal for Australian networks; range covers harmonic analysis contexts</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Earth Resistance (3-wire)</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">0.00 Ω to 9999 Ω, ±(5% + 5 digits)</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Essential for earthing system verification on TT systems and standalone earth electrodes</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Socket Test</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Earth continuity, polarity, correct connections — Pass/Fail, no trailing lead</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Dramatically speeds socket verification on large floor-plate installations</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Auto-Sequences</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Up to 6 tests per sequence</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Reduces per-socket test time; supports high-volume RCD testing workflows</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Display</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">4.3-inch colour TFT, 480 × 272 pixels, touch screen</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Clear result readout in all lighting conditions; touch-based navigation without rotary dial</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Overvoltage Category</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">600 V CAT III / 300 V CAT IV</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Safe for use at distribution boards and supply metering points</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Connectivity</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Bluetooth + Wi-Fi + USB Type-C</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Supports wireless Metrel Cloud sync and wired PC connection for ES Manager</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Battery</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">7.2 V Li-ion, 5200 mAh, rechargeable</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Charged via USB-C; no proprietary charger required in the field</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Weight</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">1.78 kg</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Compact and portable for single-handed operation across multiple work sites</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Dimensions</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">252 × 111 × 165 mm</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Fits in a standard tool bag; optimised for on-site portability</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Standards</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">IEC/EN 61557; AS/NZS 3017; EN 61010-1; EN 61010-2-030; IEC 62752; IEC 62955</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Full compliance with Australian installation testing references and international safety standards</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>EVSE Compatibility</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Optional A-1532XA adapter for Mode 3 / Type 2 EV charging station testing</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Extends capability to EVSE verification without additional instruments</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Software</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Metrel ES Manager BASIC (included); MESM PRO and Metrel Cloud (optional licences)</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Structured reporting and cloud data management for professional contractors</td>
</tr>
</tbody>
</table>
</div>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h2 class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold" data-sourcepos="137:1-137:21;11302-11322"></h2>
<blockquote>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="139:1-139:41;11324-11364">What does the Metrel MI3136 replace?</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="141:1-141:301;11366-11666">The Metrel MI3136 InstalTest COMBO XC replaces five separate instruments: a multimeter, an insulation tester, an RCD tester, a loop impedance tester, and a phase sequence tester. It performs 12 distinct tests in a single portable unit and is the direct replacement for the discontinued Metrel MI3152.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="145:1-145:83;11673-11755">Is the Metrel MI3136 compliant with Australian installation testing standards?</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="147:1-147:339;11757-12095">Yes. The MI3136 has Pass/Fail limits preset to AS/NZS 3017 and covers all mandatory tests required for initial verification and periodic inspection of low-voltage electrical installations under AS/NZS 3000. Built-in fuse tables automatically evaluate loop impedance results against the appropriate fuse rating for the selected area group.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="151:1-151:53;12102-12154">Can the Metrel MI3136 test EV charging stations?</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="153:1-153:322;12156-12477">Yes, with the optional A-1532XA EVSE Adapter. When fitted, the MI3136 can perform electrical safety and functional verification of Mode 3 AC electric vehicle charging stations with Type 2 connectors — including single push-button EVSE test sequences and professional PDF report generation. The adapter is sold separately.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="157:1-157:62;12484-12545">What is the difference between the MI3136 and the MI3155?</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="159:1-159:629;12547-13175">The MI3136 is Metrel&#8217;s mid-range installation tester, covering all mandatory tests under AS/NZS 3017 with touch-screen operation, auto-sequences, and Metrel Cloud reporting. The MI3155 EurotestXD is Metrel&#8217;s flagship industrial instrument and supports a broader adapter ecosystem — including luxmeter sensors, cable tracers (R10K receiver), current clamp accessories, and advanced TRMS measurements. The MI3136 does not accept these extended adapters. Electricians whose scope of work includes emergency lighting lux measurement, cable tracing, or current clamp-based earth resistance testing should consider the MI3155 instead.</p>
</blockquote>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<blockquote>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="163:1-163:48;13182-13229">Does the Metrel MI3136 include a carry bag?</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="165:1-165:347;13231-13577">No. The MI3136 standard set does not include a carry bag. A soft padded bag (A1289) and a large padded bag (A1551) are available as optional accessories. The MI3136 Kit includes the A1551 Large Padded Carry Bag plus a Remote Probe, Resistor Box, 4 m Green Trailing Lead, and Non-Contact Voltage Detector as a ready-to-field bundle.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="169:1-169:57;13584-13640">Can the MI3136 test sockets without a trailing lead?</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="171:1-171:355;13642-13996">Yes. The MI3136&#8217;s socket test function verifies earth continuity, correct polarity, and correct wiring connections directly from the socket outlet — without requiring a trailing lead. This is combined with Push-button Auto-Sequences (up to 6 tests per sequence) to enable fast, high-volume socket verification on residential and commercial installations.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="175:1-175:56;14003-14058">What reporting software does the Metrel MI3136 use?</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="177:1-177:410;14060-14469">The MI3136 includes Metrel ES Manager BASIC, which enables test structure creation, result management, and professional PDF report generation via PC. Wi-Fi and Bluetooth connectivity allow direct upload to Metrel Cloud Storage (optional licence), with the Metrel Cloud App providing mobile access for field-based job management. Advanced reporting functionality is available with the MESM PRO licence upgrade.</p>
</blockquote>
<p>The post <a href="https://rapid-tech.com.au/metrel-mi3136-instaltest-combo-xc/">Title: Metrel MI3136 InstalTest COMBO XC — Multifunction Installation Tester Australia</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/metrel-mi3136-instaltest-combo-xc/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Megger MFT1815 Multifunction Installation Tester &#124; CAT IV Safety &#124; Two-Wire Non-Trip Loop Testing</title>
		<link>https://rapid-tech.com.au/megger-mft1815-multifunction-installation-tester/</link>
					<comments>https://rapid-tech.com.au/megger-mft1815-multifunction-installation-tester/#respond</comments>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Tue, 11 Mar 2025 04:04:13 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=1117866</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-29" src="http://rapid-tech.com.au/wp-content/uploads/2015/12/Megger_Logo_ssml.jpg" alt="Megger_Logo_ssml" width="114" height="30" /></p>
<p>The Megger MFT1815 is an entry-level multifunction installation tester offering CAT IV safety, IP54 rating, two-wire non-trip loop testing, 200 mA continuity, and a large, clear backlit display.</p>
<p>Designed for low voltage installations, it ensures reliable, precise testing for industrial, commercial, and residential wiring while meeting IEC 60364 standards.</p>
<ul>
<li>
<div role="presentation">Three-phase RCD testing for industrial applications with no earth/ground</div>
</li>
<li>Two-wire and three-wire non-trip loop testing for RCD protected circuits</li>
<li>Simple colour-coded test selection and large clear backlit display for ease of use</li>
<li>
<div role="presentation">Auto reversing continuity test of a 200 mA test currents</div>
</li>
<li>EN61010 CATIV safety ratings and tough IP54 case</li>
</ul>
<h4><img class="alignnone size-full wp-image-19718" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" />  <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2025/03/Megger-MFT1800-Series-Datasheet.pdf" rel="noopener">Megger MFT1800 Series Datasheet</a></h4>
<p>The post <a href="https://rapid-tech.com.au/megger-mft1815-multifunction-installation-tester/">Megger MFT1815 Multifunction Installation Tester | CAT IV Safety | Two-Wire Non-Trip Loop Testing</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Megger MFT1815 Multifunction Installation Tester – Reliable and User-Friendly</strong></p>
<p>Looking for an easy-to-use, reliable multifunction installation tester? The <strong>Megger MFT1815</strong> is the perfect choice for electricians working on domestic, commercial, and industrial low-voltage electrical installations. Designed for accuracy, durability, and efficiency, this entry-level tester helps you ensure compliance with IEC 60364 standards while saving time on testing.</p>
<h3><strong>Key Features of the Megger MFT1815</strong></h3>
<h4><strong>Rugged and Durable Design (IP54 Rated)</strong></h4>
<p>The Megger MFT1815 is built to last with an IP54-rated casing that protects against dust and moisture. Whether you&#8217;re working on outdoor electrical installations or at a busy construction site, this tester is designed to perform in tough conditions.</p>
<h4><strong>Non-Trip Loop Testing</strong></h4>
<p>Safely test RCD-protected circuits without tripping the mains supply. The MFT1815 allows for two-wire and three-wire loop testing, making it both efficient and non-disruptive during inspections.</p>
<h4><strong>Intuitive and Easy-to-Use Interface</strong></h4>
<p>With its large backlit display, colour-coded rotary controls, and digital/analogue arc display, the MFT1815 simplifies test selection and reduces errors. The dual display shows fluctuating values alongside precise digital readings, making it easy to interpret your test results.</p>
<h4><strong>Enhanced Safety Features</strong></h4>
<p>Safety is a priority with the Megger MFT1815. It is rated to EN61010 CAT IV 300V standards, ensuring protection for high-energy systems. Additional safety features include full input protection and visible/audible alerts for hazardous voltages, keeping you and your device safe during use.</p>
<h3><strong>Why Choose the Megger MFT1815 Multifunction Tester?</strong></h3>
<p>The Megger MFT1815 is one of the best multifunction testers for electricians looking for a dependable, user-friendly solution. Key benefits include:</p>
<ul>
<li><strong>Affordable entry-level option</strong> in the MFT1800 series.</li>
<li><strong>Durable IP54-rated build</strong> for tough environments.</li>
<li><strong>Non-trip loop testing</strong> for safe and efficient circuit checks.</li>
<li><strong>Simple interface</strong> for fast and error-free testing.</li>
</ul>
<h3><strong>Built for Any Job</strong></h3>
<p>From small domestic electrical systems to larger commercial and industrial installations, the MFT1815 is designed to handle it all. Its portable and robust design, combined with essential safety features, makes it the trusted choice for professional electricians.</p>
<h3><strong>Order the Megger MFT1815 Today!</strong></h3>
<p>Get the <strong>Megger MFT1815 multifunction installation tester</strong> and enjoy a reliable, durable, and easy-to-use solution for your electrical testing needs. Perfect for verifying fixed wiring systems and ensuring compliance with electrical standards, this tester is a must-have for professionals.</p>
<p>&nbsp;</p>
<p><strong>Buy now</strong> and experience the performance, safety, and convenience of the Megger MFT1815!</p>
<div class="epyt-video-wrapper"><iframe  id="_ytid_13505"  width="1020" height="574"  data-origwidth="1020" data-origheight="574"  data-relstop="1" src="https://www.youtube.com/embed/1PGhnFIDyN0?enablejsapi=1&#038;autoplay=0&#038;cc_load_policy=0&#038;cc_lang_pref=&#038;iv_load_policy=1&#038;loop=0&#038;rel=0&#038;fs=1&#038;playsinline=1&#038;autohide=2&#038;theme=dark&#038;color=red&#038;controls=1&#038;disablekb=0&#038;" class="__youtube_prefs__  epyt-is-override  no-lazyload" title="Megger MFT1800 Series user guide"  allow="fullscreen; accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen data-no-lazy="1" data-skipgform_ajax_framebjll=""></iframe></div>
<p>The post <a href="https://rapid-tech.com.au/megger-mft1815-multifunction-installation-tester/">Megger MFT1815 Multifunction Installation Tester | CAT IV Safety | Two-Wire Non-Trip Loop Testing</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/megger-mft1815-multifunction-installation-tester/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Megger MET1000 All-in-One True RMS Electrical Tester &#8211; Accurate Voltage &#038; AC Current Measurement</title>
		<link>https://rapid-tech.com.au/megger-met1000-all-in-one-true-rms-electrical-tester/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Thu, 05 Sep 2024 08:16:36 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=28090</guid>

					<description><![CDATA[<p><img class="alignnone wp-image-27996" src="https://rapid-tech.com.au/wp-content/uploads/2024/08/Megger-logo.svg" alt="" width="167" height="35" /></p>
<p><a target="_blank" href="https://mymeter.com.au/product/megger-met1000-all-in-one-true-rms-electrical-tester/" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<p>The Megger MET1000 All-in-One True RMS electrical tester offers reliable voltage and current measurements up to 1000 V and 200 A AC.</p>
<p>With its durable design, safety features, and versatile functionality, it is the ideal choice for electrical professionals seeking efficiency and precision in a compact tool.</p>
<p><img class="alignnone size-full wp-image-19718" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" /> <a target="_blank" href="https://mymeter.com.au/wp-content/uploads/2024/09/Megger-MET1000-Datasheet.pdf" rel="noopener">Megger MET1000 Datasheet</a></p>
<p>The post <a href="https://rapid-tech.com.au/megger-met1000-all-in-one-true-rms-electrical-tester/">Megger MET1000 All-in-One True RMS Electrical Tester &#8211; Accurate Voltage &#038; AC Current Measurement</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 class="font-bold text-h2 leading-[45px] pt-[30px] pb-[4px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]" dir="ltr">Megger MET1000 All-in-One True RMS Electrical Tester &#8211; Overview</h2>
<p class="text-body font-regular leading-[24px] pt-[9px] pb-[2px]" dir="ltr">The Megger MET1000 All-in-One True RMS electrical tester combines functionality and practicality to meet the demanding needs of electrical professionals.</p>
<p class="text-body font-regular leading-[24px] pt-[9px] pb-[2px]" dir="ltr">This comprehensive device provides an accurate and reliable solution for measuring voltage and current in various environments, including commercial, industrial, and domestic settings.</p>
<p class="text-body font-regular leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Crafted with user convenience in mind, the MET1000 features a detachable test lead system and easy-to-read LED and LCD displays, ensuring that both seasoned electricians and electrical engineers have a robust handheld tool at their disposal.</p>
<h2 class="font-bold text-h3 leading-[36px] pt-[21px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]" dir="ltr">Key Features</h2>
<ul class="pt-[9px] pb-[2px] pl-[24px] list-disc [&amp;_ul]:pt-[5px] pt-[5px]">
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="1"><b><strong class="font-bold">Versatile Voltage and Current Measurement</strong></b>: Capable of measuring AC/DC voltage up to 1000 V and providing 200 A AC current measurements, the MET1000 is designed for everyday use. Whether you are troubleshooting electrical systems or conducting routine maintenance, this tester is indispensable.</li>
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="2"><b><strong class="font-bold">True RMS Measurements</strong></b>: The MET1000 excels in providing True RMS readings for AC voltage and current, ensuring that users attain accurate measurement results even in non-linear power systems.</li>
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="3"><b><strong class="font-bold">Robust and Durable Design</strong></b>: Rated CAT IV 600 V and CAT III 1000 V, the MET1000 is built to withstand harsh working conditions. Its IP65 rating further enhances its durability, making it suitable for use in challenging environments. The instrument’s protective finger guard and ergonomic design help ensure user safety at all times.</li>
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="4"><b><strong class="font-bold">Enhanced Functionality</strong></b>: The tester features auto-ranging voltage measurement, phase rotation testing, and a single pole voltage test, which are critical for efficient electrical diagnostics. Additionally, the built-in current clamp simplifies AC current measurements, enabling professionals to work quickly and effectively.</li>
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="5"><b><strong class="font-bold">Safety Features</strong></b>: Equipped with a bright LED torch, the MET1000 aids in working safely in low-light conditions. GS38 shrouds are included to ensure compliance with the latest safety standards, further solidifying the instrument’s suitability for professional use.</li>
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="6"><b><strong class="font-bold">Easy Storage and Portability</strong></b>: The MEGGER MET1000 comes with a carrying holster and incorporates easy-to-use probe mounts on the rear, ensuring that your workspace remains organised and your tools protected.</li>
</ul>
<h2 class="font-bold text-h3 leading-[36px] pt-[21px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]" dir="ltr">Why Choose the Megger MET1000?</h2>
<p class="text-body font-regular leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Investing in the Megger MET1000 All-in-One True RMS electrical tester means choosing reliability and efficiency.</p>
<p>This instrument reduces the need for multiple testers, streamlining your toolkit. With an intuitive design and comprehensive safety features, it enhances user confidence and performance on the job.</p>
<p class="text-body font-regular leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Whether you&#8217;re conducting electrical inspections, performing installations, or troubleshooting, the MET1000 is a powerful ally that delivers accurate results.</p>
<h3 class="font-bold text-h4 leading-[30px] pt-[15px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]" dir="ltr">Specifications Summary</h3>
<ul class="pt-[9px] pb-[2px] pl-[24px] list-disc [&amp;_ul]:pt-[5px] pt-[5px]">
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="1"><b><strong class="font-bold">Electrical Measurement Categories</strong></b>: CAT III 1000 V, CAT IV 600 V</li>
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="2"><b><strong class="font-bold">Voltage Measuring Range (AC)</strong></b>: 6.0 &#8211; 999.9 V (with batteries), 45 V &#8211; 999.9 V (without batteries)</li>
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="3"><b><strong class="font-bold">Voltage Measuring Range (DC)</strong></b>: 7.0 &#8211; 999.9 V (with batteries), 45 V &#8211; 999.9 V (without batteries)</li>
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="4"><b><strong class="font-bold">AC Current Measurement</strong></b>: Up to 200 A</li>
</ul>
<h2 class="font-bold text-h3 leading-[36px] pt-[21px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]" dir="ltr">Conclusion</h2>
<p class="text-body font-regular leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Choose the Megger MET1000 All-in-One True RMS electrical tester for a dependable and multifunctional tool that meets the challenges of today’s electrical testing demands.</p>
<p class="text-body font-regular leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Its combination of advanced features, safety measures, and durable construction makes it an essential addition to any professional electrician’s toolkit. Visit our website to learn more and purchase yours today.</p>
<p>The post <a href="https://rapid-tech.com.au/megger-met1000-all-in-one-true-rms-electrical-tester/">Megger MET1000 All-in-One True RMS Electrical Tester &#8211; Accurate Voltage &#038; AC Current Measurement</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>