<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>LCR Meter Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/product-tag/lcr-meter/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/product-tag/lcr-meter/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Fri, 01 Aug 2025 01:28:44 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.5</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>LCR Meter Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/product-tag/lcr-meter/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>UNI-T UT622 Series &#8211; High-Precision Handheld LCR Meter for In-depth Inductance, Capacitance, and Resistance Measurements</title>
		<link>https://rapid-tech.com.au/uni-t-ut622-series-high-precision-handheld-lcr-meter-for-in-depth-inductance-capacitance-and-resistance-measurements/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Wed, 18 Oct 2023 01:59:03 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=27078</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-14791" src="https://rapid-tech.com.au/wp-content/uploads/2020/03/UNI-T-Logo.png" alt="UNI-T Logo" width="222" height="58" /></p>
<p><a target="_blank" href="https://mymeter.com.au/product/uni-t-ut622e-the-ultimate-handheld-precision-lcr-meter-for-detailed-inductance-capacitance-and-resistance-readings" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<p class="text-base font-normal text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Introducing the <b><strong class="font-bold">UNI-T UT622 Series</strong></b> - your high-precision handheld LCR meter solution.</p>
<p class="text-base font-normal text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">This powerful and versatile tool, designed with a clear 2.8'' TFT LCD display, is perfect for all your in-depth measurements of inductance, capacitance, and resistance.</p>
<p class="text-base font-normal text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Featuring unique modes like the <b><strong class="font-bold">Recording Mode</strong></b> for dynamic data statistics and the <b><strong class="font-bold">Tolerance Mode</strong></b> for component sorting, it is a must-have for laboratories, production lines, and maintenance points.</p>
<p class="text-base font-normal text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">With 3-terminal and 5-terminal test ports allowing a range of tests and dual power supply methods, experience uninterrupted, accurate measurements. Make the UT622 Series a part of your workflow today and redefine precision.</p>
<p dir="ltr">[embedyt] https://www.youtube.com/watch?v=cCIFV28bQR0[/embedyt]</p>
<h4><img class="size-full wp-image-19718 alignnone" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" />   <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2023/10/UT622-Datesheet.pdf" rel="noopener">UT622 Datesheet</a><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2023/08/Uni-T-UT255B-Datasheet.pdf" rel="noopener"></a></h4>
<p>The post <a href="https://rapid-tech.com.au/uni-t-ut622-series-high-precision-handheld-lcr-meter-for-in-depth-inductance-capacitance-and-resistance-measurements/">UNI-T UT622 Series &#8211; High-Precision Handheld LCR Meter for In-depth Inductance, Capacitance, and Resistance Measurements</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Introducing the <b><strong class="font-bold">UNI-T UT622 SERIES</strong></b> &#8211; your ultimate handheld LCR metre solution! With its powerful functionality, unrivalled accuracy, and swift operation, it&#8217;s perfectly designed for long-lasting and precision measurements. Its 2.8-inch TFT LCD display adds an intuitive edge to your user experience, making it effortless to read and understand.</p>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">The UNI-T UT622 SERIES is an ideal choice for a variety of applications. Its exceptional versatility makes it suitable for in-depth measurements and screening of inductance, capacitance, and resistance. Whether you&#8217;re working in a laboratory, on a production line, or at your maintenance point, the UT622 will serve your needs flawlessly.</p>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">One of its standout features is the <b><strong class="font-bold">Recording Mode,</strong></b> which enables dynamic data statistics, allowing you to easily obtain the Average, Maximum, Minimum, and Number of records. For component sorting, you&#8217;ll find the <b><strong class="font-bold">Tolerance Mode</strong></b> incredibly helpful. Here, you can set the nominal value, tolerance limit, alarm, LED indicator, and counter. It even displays GO/NG discrimination results.</p>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">The UT622 SERIES offers both 3-terminal and 5-terminal test ports, supporting a range of tests and accommodating both convenient and high-precision testing needs. Powered by a lithium-polymer battery and a USB power adapter, it ensures uninterrupted operation, even during the longest workdays.</p>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Experience the power of precision with the UNI-T UT622 SERIES. A tool that truly redefines accurate measurement. Order yours today and make precision measurement a part of your everyday workflow.</p>
<div>
<h3>MODEL — UT622E</h3>
<ul>
<li>MAX. TEST FREQUENCY: 100kHz</li>
<li>ACCURACY: 0.1%</li>
<li>DISPLAY COUNT: 99999</li>
<li>MAX. TEST RATE: 20 times/s</li>
<li>DCR: YES</li>
<li>CONNECTIVITY: Mini-USB</li>
<li>DISPLAY: 2.8&#8221; TFT LCD</li>
</ul>
</div>
<p dir="ltr"><div class="row"  id="row-686119611">

	<div id="col-1127385022" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<a href="https://rapid-tech.com.au/wp-content/uploads/2023/10/1622184053469923.png"><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-27079" src="https://rapid-tech.com.au/wp-content/uploads/2023/10/1622184053469923.png" alt="" width="800" height="500" srcset="https://rapid-tech.com.au/wp-content/uploads/2023/10/1622184053469923.png 800w, https://rapid-tech.com.au/wp-content/uploads/2023/10/1622184053469923-300x188.png 300w, https://rapid-tech.com.au/wp-content/uploads/2023/10/1622184053469923-768x480.png 768w, https://rapid-tech.com.au/wp-content/uploads/2023/10/1622184053469923-600x375.png 600w" sizes="(max-width: 800px) 100vw, 800px" /></a><br />
		</div>
					</div>

	

	<div id="col-1448740141" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<h4>Function panel introduction</h4>
<p>1. Power switch: long press to turn on, short press to turn off</p>
<p>2. Arrow keys: select menu operation keys</p>
<p>3. Trigger key: trigger/select trigger mode</p>
<p>4. D/Q/θ/ESR: secondary parameter selection</p>
<p>5. FREQ/REC: Frequency 100Hz, 120Hz, 1kHz, 10kHz, 100kHz selection and record mode button.</p>
<p>6. LEVEL/TOL: 0.1V, 0.3V, 1V, switch and tolerance mode buttons</p>
<p>7. L/C/R/Z/AUTO: main parameters and automatic identification.</p>
<p>8. SPEED/P-S: Test speed and equivalent mode switch button</p>
<p>9. CLEAR/UTIL: CLEAR clear and UTIL practical configuration menu.</p>
<p>&nbsp;</p>
		</div>
					</div>

	
<p dir="ltr"></div>
<p>The post <a href="https://rapid-tech.com.au/uni-t-ut622-series-high-precision-handheld-lcr-meter-for-in-depth-inductance-capacitance-and-resistance-measurements/">UNI-T UT622 Series &#8211; High-Precision Handheld LCR Meter for In-depth Inductance, Capacitance, and Resistance Measurements</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Keysight U1700 Series Handheld Capacitance and LCR Meters</title>
		<link>https://rapid-tech.com.au/keysight-u1700-series-handheld-capacitance-and-lcr-meters/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Wed, 15 Mar 2023 03:25:07 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=26262</guid>

					<description><![CDATA[<p class="ai-optimize-15"><img class="size-medium wp-image-19245 alignnone" src="https://rapid-tech.com.au/wp-content/uploads/2021/08/keysight-logo-300x70.png" alt="keysight logo" width="300" height="70" /><a href="https://rapid-tech.com.au/wp-content/uploads/2021/08/keysight-logo.jpg"></a></p>
<p class="ai-optimize-16">Take advantage of Keysight's handheld capacitance and LCR meters to get fast, accurate measurements at an affordable price. Their SMD tweezer option offers superior noise immunity - so you save time and money!</p>
<p><img class="alignnone size-full wp-image-19222" src="https://rapid-tech.com.au/wp-content/uploads/2021/08/3-year-warranty.png" alt="" width="180" height="64" /></p>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/keysight-u1700-series-handheld-capacitance-and-lcr-meters/">Keysight U1700 Series Handheld Capacitance and LCR Meters</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Keysight U1700 Series Handheld Capacitance and LCR Meters</h3>
<p>If you require LCR testing on the go, the U1701B handheld capacitance meters are a must-have! These incredible tools come with everything necessary for electronics assembly and passive component troubleshooting. What&#8217;s more, up to 25 sets of High/Low limits allow for unparalleled accuracy and precision in your results.</p>
<p>The U1731C/32C/33C handheld LCR meters offer a capability not found in most benchtop models: the ability to measure frequencies up to 100 kHz!</p>
<p>Maximize noise immunity and save money with Option-SMD. Each order comes equipped with a convenient soft carrying case, as well as an SMD tweezer—a combination that will give you the highest value for your money. The SMD tweezer is designed to measure components on SMDs and can be used in tandem with handheld LCR meters’ guard terminals for better noise immunity results.</p>
<h2>Find the Model that&#8217;s Right for You</h2>
<div class="row"  id="row-1131691767">

	<div id="col-75537917" class="col medium-3 large-3"  >
				<div class="col-inner"  >
			
			
<div class="dynamic-table__models--block-heading">
<div class="dynamic-table__models--heading"><strong>U1701B</strong></div>
<div class="dynamic-table__models--sub-heading">Handheld Capacitance Meter</div>
</div>
<div class="dynamic-table__models--body">
<div class="dynamic-table__models--footer has-price has-quote has-buy" data-buyquote-model="U1701B">
<div class="dynamic-table__button--wrapper configurator-wrap"></div>
</div>
<div class="dynamic-table__models--block-wrapper dynamic-table--fontColorGray">
<div class="dynamic-table__models--block"><span class="dynamic-table__models--value">Keysight’s U1701B handheld capacitance meter puts a new level of convenience, performance and reliability into the world of the capacitance meter.</span></div>
</div>
</div>
		</div>
					</div>

	

	<div id="col-1500340981" class="col medium-3 large-3"  >
				<div class="col-inner"  >
			
			
<div class="dynamic-table__models--block-heading">
<div class="dynamic-table__models--heading"><strong>U1731C</strong></div>
<div class="dynamic-table__models--sub-heading">100Hz/120Hz/1kHz Handheld LCR Meter</div>
<div class="dynamic-table__models--sub-heading"></div>
</div>
<div class="dynamic-table__models--body">
<div class="dynamic-table__models--block-wrapper dynamic-table--fontColorGray">
<div class="dynamic-table__models--block"><span class="dynamic-table__models--value">U1731C 100Hz/120Hz/1kHz Handheld LCR Meter</span></div>
</div>
</div>
		</div>
					</div>

	

	<div id="col-834032034" class="col medium-3 large-3"  >
				<div class="col-inner"  >
			
			
<div class="dynamic-table__models--block-heading">
<div class="dynamic-table__models--heading"><strong>U1732C</strong></div>
<div class="dynamic-table__models--sub-heading">100Hz/120Hz/1kHz/10kHz Handheld LCR Meter</div>
</div>
<div class="dynamic-table__models--body">
<div class="dynamic-table__models--footer has-price has-quote has-buy" data-buyquote-model="U1732C">
<div class="dynamic-table__button--wrapper configurator-wrap"></div>
</div>
<div class="dynamic-table__models--block-wrapper dynamic-table--fontColorGray">
<div class="dynamic-table__models--block"><span class="dynamic-table__models--value">U1732C 100Hz/120Hz/1kHz/10kHz Handheld LCR Meter</span></div>
</div>
</div>
		</div>
					</div>

	
</div>
<div class="dynamic-table__models--block">
<div class="row"  id="row-726591078">
	<div id="col-1752811881" class="col medium-3 large-3"  >
				<div class="col-inner"  >
			
			
<div class="dynamic-table__models--block-heading">
<div class="dynamic-table__models--heading"><strong>U1732C</strong></div>
<div class="dynamic-table__models--sub-heading">100Hz/120Hz/1kHz/10kHz Handheld LCR Meter</div>
</div>
<div class="dynamic-table__models--body">
<div class="dynamic-table__models--footer has-price has-quote has-buy" data-buyquote-model="U1732C">
<div class="dynamic-table__button--wrapper configurator-wrap"></div>
</div>
<div class="dynamic-table__models--block-wrapper dynamic-table--fontColorGray">
<div class="dynamic-table__models--block"><span class="dynamic-table__models--value">U1732C 100Hz/120Hz/1kHz/10kHz Handheld LCR Meter</span></div>
</div>
</div>
		</div>
					</div>

	

	<div id="col-2053933574" class="col medium-3 large-3"  >
				<div class="col-inner"  >
			
			
<div class="dynamic-table__models--block-heading">
<div class="dynamic-table__models--heading"><strong>U1733C</strong></div>
<div class="dynamic-table__models--sub-heading">100Hz/120Hz/1kHz/10kHz/100kHz Handheld LCR Meter</div>
</div>
<div class="dynamic-table__models--body">
<div class="dynamic-table__models--footer has-price has-quote has-buy" data-buyquote-model="U1733C">
<div class="dynamic-table__button--wrapper configurator-wrap"></div>
</div>
<div class="dynamic-table__models--block-wrapper dynamic-table--fontColorGray">
<div class="dynamic-table__models--block"><span class="dynamic-table__models--value">The U1733C LCR meters allow you to measure frequencies as high as 100 kHz, a capability typically found only in benchtop meters. It come with a 3-year warranty which is backed by Keysight’s outstanding service and support.</span></div>
</div>
</div>
		</div>
					</div>

	

	<div id="col-1003937357" class="col medium-4 large-4"  >
				<div class="col-inner"  >
			
			
		</div>
					</div>

	
</div>
</div>
<div></div>
<div class="dynamic-table__models--items-wrapper slick-slide slick-current slick-active" data-slick-index="0" aria-hidden="false">
<div class="dynamic-table__models--items-wrapper slick-slide slick-active" data-slick-index="2" aria-hidden="false">
<div class="dynamic-table__models--items">
<div class="dynamic-table__models--wrapper">
<div class="dynamic-table__models--block-heading"></div>
<div class="dynamic-table__models--body">
<div class="dynamic-table__models--block-wrapper dynamic-table--fontColorGray">
<div class="dynamic-table__models--block"></div>
</div>
</div>
</div>
</div>
</div>
<div class="dynamic-table__models--items-wrapper slick-slide slick-current slick-active" data-slick-index="3" aria-hidden="false">
<div class="dynamic-table__models--items">
<div class="dynamic-table__models--wrapper">
<div class="dynamic-table__models--block-heading"></div>
<div class="dynamic-table__models--body">
<div class="dynamic-table__models--block-wrapper dynamic-table--fontColorGray">
<div class="dynamic-table__models--block"></div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="dynamic-table__models--items-wrapper slick-slide slick-active" data-slick-index="1" aria-hidden="false">
<div class="dynamic-table__models--items">
<div class="dynamic-table__models--wrapper">
<div class="dynamic-table__models--block-heading"></div>
<div class="dynamic-table__models--body">
<div class="dynamic-table__models--block-wrapper dynamic-table--fontColorGray">
<div class="dynamic-table__models--block"></div>
</div>
</div>
</div>
</div>
</div>
<div class="dynamic-table__models--items-wrapper slick-slide slick-active" data-slick-index="2" aria-hidden="false">
<div class="dynamic-table__models--items">
<div class="dynamic-table__models--wrapper">
<div class="dynamic-table__models--block-heading"></div>
<div class="dynamic-table__models--body">
<div class="dynamic-table__models--block-wrapper dynamic-table--fontColorGray">
<div class="dynamic-table__models--block"></div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://rapid-tech.com.au/keysight-u1700-series-handheld-capacitance-and-lcr-meters/">Keysight U1700 Series Handheld Capacitance and LCR Meters</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>R&#038;S LCX LCR METER &#124;  DC, 4 Hz to 10 MHz &#124; R&#038;S LCX100 LCR &#124; R&#038;S LCX200</title>
		<link>https://rapid-tech.com.au/rslcx100-lcr-meter-dc-4-hz-to-10-mhz/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Tue, 15 Mar 2022 00:09:55 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=21632</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-16086" src="https://rapid-tech.com.au/wp-content/uploads/2020/07/RS-New-Logo-Smaller.jpg" alt="" width="304" height="90" /></p>
<p>R&#38;S<span style="font-weight: 400;">®</span>LCX100 LCR meters cover a frequency range of 4 Hz to 300 kHz. The R&#38;S®LCX200 has an upper frequency limit of 500 kHz and can be extended to 1 MHz or 10 MHz using software options when needed. They are ideal for challenging applications in research, development and production. With its internal bias and external bias functions, comprehensive analysis options, and versatile test fixtures, the product can be used for all kinds of applications.</p>
<h4><img class="alignnone size-full wp-image-19718" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" />  <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2022/03/RS LCX-LCR-Meters-Datasheet.pdf" rel="noopener">R&#38;S LCX LCR Meters Datasheet</a></h4>
<p>The post <a href="https://rapid-tech.com.au/rslcx100-lcr-meter-dc-4-hz-to-10-mhz/">R&#038;S LCX LCR METER |  DC, 4 Hz to 10 MHz | R&#038;S LCX100 LCR | R&#038;S LCX200</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3><strong>Benefits and Key Features</strong></h3>
<p><strong>Universal LCR meter</strong></p>
<ul>
<li>Fast, accurate and versatile (Fast: ≤ 15 ms, Medium: ≤ 100 ms, Slow: ≤ 500 ms)</li>
<li>Selectable frequency range (4 Hz to 10 MHz)</li>
<li>Test signals for all requirements (100 mV to 10 V &#8211; up to 200 mA)</li>
<li>DC bias (Voltage of up to 10 V)</li>
<li>Measurement functions</li>
<li>Data logging function (up to 10 sample/s)</li>
</ul>
<p><strong>Options for advanced applications</strong></p>
<ul>
<li>R&amp;S LCX-K106 advanced analysis functions</li>
<li>R&amp;S LCX-K107 digital I/O ports and binning function</li>
<li>R&amp;S LCX-K108 extended bias functions</li>
<li>R&amp;S LCX-K201/-K210 frequency upgrade to 1 MHz/10 MHz</li>
</ul>
<p><strong>Easy operation</strong></p>
<ul>
<li>High-resolution touchscreen</li>
<li>Graphical representation of measurements</li>
<li>Save and recall instrument settings</li>
</ul>
<p><strong>Test fixtures</strong></p>
<ul>
<li>R&amp;S LCX-Z1 test fixture for axial/radial lead type devices</li>
<li>R&amp;S LCX-Z2 Kelvin clip lead</li>
<li>R&amp;S LCX-Z3 test fixture for SMD components</li>
<li>R&amp;S LCX-Z4 test tweezers for SMD components</li>
<li>R&amp;S LCX-Z5 transformer test cables</li>
<li>R&amp;S LCX-Z11 BNC extension</li>
</ul>
<div class="epyt-video-wrapper"><iframe  id="_ytid_36358"  width="1020" height="574"  data-origwidth="1020" data-origheight="574"  data-relstop="1" src="https://www.youtube.com/embed/jHghAqSg9tM?enablejsapi=1&autoplay=0&cc_load_policy=0&cc_lang_pref=&iv_load_policy=1&loop=0&rel=0&fs=1&playsinline=1&autohide=2&theme=dark&color=red&controls=1&disablekb=0&" class="__youtube_prefs__  no-lazyload" title="R&amp;S LCX LCR METER"  allow="fullscreen; accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen data-no-lazy="1" data-skipgform_ajax_framebjll=""></iframe></div>
<p>&nbsp;</p>
<p><span style="font-weight: 400;">R&amp;S®LCX100 LCR meters cover a frequency range of 4 Hz to 300 kHz. The R&amp;S®LCX200 has an upper frequency limit of 500 kHz and can be extended to 1 MHz or 10 MHz using software options when needed. </span></p>
<p><span style="font-weight: 400;">The R&amp;S®LCX200 offers an upper frequency limit of 500 kHz and can be extended to 1 MHz or 10 MHz using software options when needed. </span></p>
<p><span style="font-weight: 400;">DC measurements are available on all instruments. Most applications can be covered with voltages as high as 10 V generated internally. It is also possible to apply bias voltages of up to 40 V externally. </span></p>
<p><span style="font-weight: 400;">All measured values are recorded up to 10 times per second using the fast logging function.</span></p>
<p><span style="font-weight: 400;">The advanced analysis function allows you to perform dynamic impedance measurements. These sweep measurements determine the impedance values for a series of frequency values or other parameters. </span></p>
<p><span style="font-weight: 400;">Digital I/O ports can be used to trigger and control measurements externally. Using the binning function, the measured components can be sorted by their values into eight categories. </span></p>
<div class="row"  id="row-373625028">

	<div id="col-339687188" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<figure id="attachment_21635" aria-describedby="caption-attachment-21635" style="width: 412px" class="wp-caption alignnone"><a href="https://rapid-tech.com.au/wp-content/uploads/2022/03/Up-to-four-measurement-parameters-can-be-shown-on-the-display-at-the-same-time.jpg"><img decoding="async" class="wp-image-21635" src="https://rapid-tech.com.au/wp-content/uploads/2022/03/Up-to-four-measurement-parameters-can-be-shown-on-the-display-at-the-same-time.jpg" alt="Up to four measurement parameters can be shown on the display at the same time" width="412" height="241" srcset="https://rapid-tech.com.au/wp-content/uploads/2022/03/Up-to-four-measurement-parameters-can-be-shown-on-the-display-at-the-same-time.jpg 798w, https://rapid-tech.com.au/wp-content/uploads/2022/03/Up-to-four-measurement-parameters-can-be-shown-on-the-display-at-the-same-time-300x176.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2022/03/Up-to-four-measurement-parameters-can-be-shown-on-the-display-at-the-same-time-768x449.jpg 768w, https://rapid-tech.com.au/wp-content/uploads/2022/03/Up-to-four-measurement-parameters-can-be-shown-on-the-display-at-the-same-time-600x351.jpg 600w" sizes="(max-width: 412px) 100vw, 412px" /></a><figcaption id="caption-attachment-21635" class="wp-caption-text">Up to four measurement parameters can be shown on the display at the same time</figcaption></figure>
		</div>
					</div>

	

	<div id="col-225536757" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<figure id="attachment_21634" aria-describedby="caption-attachment-21634" style="width: 407px" class="wp-caption alignnone"><a href="https://rapid-tech.com.au/wp-content/uploads/2022/03/Test-signals-and-measurement-functions-can-be-configured-as-required.jpg"><img loading="lazy" decoding="async" class="wp-image-21634" src="https://rapid-tech.com.au/wp-content/uploads/2022/03/Test-signals-and-measurement-functions-can-be-configured-as-required.jpg" alt="Test signals and measurement functions can be configured as required" width="407" height="238" srcset="https://rapid-tech.com.au/wp-content/uploads/2022/03/Test-signals-and-measurement-functions-can-be-configured-as-required.jpg 798w, https://rapid-tech.com.au/wp-content/uploads/2022/03/Test-signals-and-measurement-functions-can-be-configured-as-required-300x176.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2022/03/Test-signals-and-measurement-functions-can-be-configured-as-required-768x449.jpg 768w, https://rapid-tech.com.au/wp-content/uploads/2022/03/Test-signals-and-measurement-functions-can-be-configured-as-required-600x351.jpg 600w" sizes="auto, (max-width: 407px) 100vw, 407px" /></a><figcaption id="caption-attachment-21634" class="wp-caption-text">Test signals and measurement functions can be configured as required</figcaption></figure>
		</div>
					</div>

	
</div>
<p><span style="font-weight: 400;">With the large capacitive touchscreen, you can operate the instruments in a modern and intuitive way and visualize the results of your measurements graphically. </span></p>
<p><span style="font-weight: 400;">Remote controllability and rack installation make the R&amp;S®LCX ideal for system applications.</span></p>
<p><strong>Ideal for use in labs and test systems</strong></p>
<ul>
<li>Tailored for use in labs and system racks</li>
<li>Full remote capabilities</li>
<li>Advanced instrument design: compact form factor, quiet operation</li>
</ul>
<p class="p2"><b>Key</b><b> </b><b>facts</b></p>
<table class="t1" style="height: 398px;" width="688" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="td1" valign="top">
<p class="p1"><b>Features<span class="Apple-converted-space"> </span></b></p>
</td>
<td class="td1" valign="top">
<p class="p1"><b>R&amp;S®LCX100<span class="Apple-converted-space"> </span></b></p>
</td>
<td class="td1" valign="top">
<p class="p1"><b>R&amp;S®LCX200<span class="Apple-converted-space"> </span></b></p>
</td>
</tr>
<tr>
<td class="td1" valign="top">
<p class="p2">Test signal frequency<span class="Apple-converted-space"> </span></p>
</td>
<td class="td1" valign="top">
<p class="p2">DC, 4 Hz to 300 kHz<span class="Apple-converted-space"> </span></p>
</td>
<td class="td1" valign="top">
<p class="p2">DC, 4 Hz to 10 MHz (option)<span class="Apple-converted-space"> </span></p>
</td>
</tr>
<tr>
<td class="td1" valign="top">
<p class="p2">Test signal voltage<span class="Apple-converted-space"> </span></p>
</td>
<td class="td1" valign="top">
<p class="p2">100 mV to 10 V<span class="Apple-converted-space"> </span></p>
</td>
<td class="td1" valign="top">
<p class="p2">&lt; 1 MHz: 100 mV to 10 V,<span class="Apple-converted-space"> </span></p>
<p class="p2">&gt; 1 MHz: 100 mV to 2 V<span class="Apple-converted-space"> </span></p>
</td>
</tr>
<tr>
<td class="td1" valign="top">
<p class="p2">DC bias voltage (internal)<span class="Apple-converted-space"> </span></p>
</td>
<td class="td1" valign="top">
<p class="p2">0 V to +10 V<span class="Apple-converted-space"> </span></p>
</td>
</tr>
<tr>
<td class="td1" valign="top">
<p class="p2">DC bias current (internal)<span class="Apple-converted-space"> </span></p>
</td>
<td class="td1" valign="top">
<p class="p2">0 mA to 200 mA<span class="Apple-converted-space"> </span></p>
</td>
</tr>
<tr>
<td class="td1" valign="top">
<p class="p2">External DC bias voltage, input<span class="Apple-converted-space"> </span></p>
</td>
<td class="td1" valign="top">
<p class="p2">0 V to +40 V<span class="Apple-converted-space"> </span></p>
</td>
</tr>
<tr>
<td class="td1" valign="top">
<p class="p2">Source impedance<span class="Apple-converted-space"> </span></p>
</td>
<td class="td1" valign="top">
<p class="p2">100 Ω, 10 Ω<span class="Apple-converted-space"> </span></p>
</td>
</tr>
<tr>
<td class="td1" valign="top">
<p class="p2">Measurement range<span class="Apple-converted-space"> </span></p>
</td>
<td class="td1" valign="top">
<p class="p2">100 mΩ to 100 MΩ<span class="Apple-converted-space"> </span></p>
</td>
</tr>
<tr>
<td class="td1" valign="top">
<p class="p2">Basic accuracy for impedance measurements<span class="Apple-converted-space"> </span></p>
</td>
<td class="td1" valign="top">
<p class="p2">0.05 %</p>
</td>
</tr>
</tbody>
</table>
<p class="p9"><span class="s6"><span class="Apple-converted-space"> </span></span></p>
<p>The post <a href="https://rapid-tech.com.au/rslcx100-lcr-meter-dc-4-hz-to-10-mhz/">R&#038;S LCX LCR METER |  DC, 4 Hz to 10 MHz | R&#038;S LCX100 LCR | R&#038;S LCX200</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Handheld LCR Meter &#124; Keysight U1733C &#124; 100Hz/120Hz/1kHz/10kHz/100kHz</title>
		<link>https://rapid-tech.com.au/handheld-lcr-meter-keysight-u1733c-100hz-120hz-1khz-10khz-100khz/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Thu, 24 Feb 2022 04:17:14 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=20931</guid>

					<description><![CDATA[<p><img class="size-medium wp-image-19245 alignnone" src="https://rapid-tech.com.au/wp-content/uploads/2021/08/keysight-logo-300x70.png" alt="keysight logo" width="300" height="70" /><a href="https://rapid-tech.com.au/wp-content/uploads/2021/08/keysight-logo.jpg"></a></p>
<p><a target="_blank" href="http://mymeter.com.au/product/handheld-lcr-meter-keysight-u1733c-100hz-120hz-1khz-10khz-100khz/" rel="noopener"><img class="alignnone size-full wp-image-17843" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/BUY-NOW-form-My-Meter-e1620004827208.png" alt="Buy now form My Meter" width="220" height="55" /></a></p>
<p>With the Keysight Technologies U1730C Series handheld LCR meters, you can measure at frequencies as high as 100 kHz, a feature typically only found in benchtop meters.</p>
<h4><span style="font-weight: 400;">Key features </span></h4>
<ul>
<li>20,000 counts resolution</li>
<li>0.2% accuracy</li>
<li>Wide LCR ranges with 5 selectable test frequencies (100Hz, 120Hz, 1kHz, 10kHz, and 100kHz)</li>
<li>Auto identification (Ai) automatically determines and displays component type and measurements</li>
<li>Detailed component analysis with DCR, ESR, Z, D, Q, Ө functions</li>
<li>Battery life of 16 hours/Ac-powered</li>
<li>IR-to-USB connectivity for data logging to PC</li>
</ul>
<p><img class="alignnone size-full wp-image-19222" src="https://rapid-tech.com.au/wp-content/uploads/2021/08/3-year-warranty.png" alt="" width="180" height="64" /></p>
<h4><img class="size-full wp-image-19718 alignnone" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" />    <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2022/02/Keysight-U1733C-Datasheet.pdf" rel="noopener">Keysight U1733C Datasheet</a></h4>
<p>The post <a href="https://rapid-tech.com.au/handheld-lcr-meter-keysight-u1733c-100hz-120hz-1khz-10khz-100khz/">Handheld LCR Meter | Keysight U1733C | 100Hz/120Hz/1kHz/10kHz/100kHz</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>With the Keysight Technologies U1730C Series handheld LCR meters, you can measure at frequencies as high as 100 kHz, a feature typically only found in benchtop meters.</p>
<p>Measurements can be completed more quickly by using the one-touch automatic identification function button, which displays component type and further component analysis such as Z, ESR, and DCR.</p>
<p>These LCR meters operate on a battery that can last up to 16 hours and are perfect for testing on the go. You can easily conduct basic LCR measurements at an affordable price with the U1730C Series that is designed for your convenience.</p>
<p>The post <a href="https://rapid-tech.com.au/handheld-lcr-meter-keysight-u1733c-100hz-120hz-1khz-10khz-100khz/">Handheld LCR Meter | Keysight U1733C | 100Hz/120Hz/1kHz/10kHz/100kHz</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Handheld LCR Meter &#124; Keysight U1732C &#124;  100Hz/120Hz/1kHz/10kHz</title>
		<link>https://rapid-tech.com.au/handheld-lcr-meter-keysight-u1732c-100hz-120hz-1khz-10khz/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Fri, 22 Oct 2021 01:44:07 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=20165</guid>

					<description><![CDATA[<p><img class="size-medium wp-image-19245 alignnone" src="https://rapid-tech.com.au/wp-content/uploads/2021/08/keysight-logo-300x70.png" alt="keysight logo" width="300" height="70" /><a href="https://rapid-tech.com.au/wp-content/uploads/2021/08/keysight-logo.jpg"></a></p>
<p><a target="_blank" href="https://mymeter.com.au/product/handheld-lcr-meter-keysight-u1732c-100hz-120hz-1khz-10khz/" rel="noopener"><img class="alignnone size-full wp-image-17843" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/BUY-NOW-form-My-Meter-e1620004827208.png" alt="Buy now form My Meter" width="220" height="55" /></a></p>
<p><span style="font-weight: 400;">The Keysight U1732C LCR meter features 20,000 counts resolution and four selectable test frequencies (100 Hz, 120 Hz, 1 kHz, 10 kHz). Furthermore, provide more detailed component analyses, such as Z, ESR, and DCR.</span></p>
<h4><span style="font-weight: 400;">Key features </span></h4>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">20,000 counts resolution</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">0.2% basic accuracy</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Wide LCR ranges with three to five selectable test frequencies (up to 100 kHz for U1733C)</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Auto identification (Ai) automatically determines and displays component type and measurements </span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Detailed component analysis with DCR, ESR, Z, D, Q, and θ functions </span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Battery life of 16 hours/AC-powered </span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">– IR-to-USB connectivity for data logging to PC</span></li>
</ul>
<p><img class="alignnone size-full wp-image-19222" src="https://rapid-tech.com.au/wp-content/uploads/2021/08/3-year-warranty.png" alt="" width="180" height="64" /></p>
<h4><img class="size-full wp-image-19718 alignnone" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" />    <a href="https://rapid-tech.com.au/wp-content/uploads/2021/10/Keysight-U1732C-Datasheet.pdf">Keysight U1732C Datasheet</a></h4>
<p>The post <a href="https://rapid-tech.com.au/handheld-lcr-meter-keysight-u1732c-100hz-120hz-1khz-10khz/">Handheld LCR Meter | Keysight U1732C |  100Hz/120Hz/1kHz/10kHz</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3><b>Keysight U1732C LCR Meter</b></h3>
<p><span style="font-weight: 400;">With the Keysight U1730C Series LCR meters, you can measure frequencies up to 100 kHz, a capability typically found only in benchtop meters. Utilize the one-touch automatic identification function button which displays component type and more detailed component analysis such as Z, ESR, and DCR. With a battery life of up to 16 hours, these LCR meters are perfect for testing on the go. You can perform basic LCR measurements quickly and easily with the U1730C Series, which is built for your convenience.</span></p>
<h4><span style="font-weight: 400;">Key features </span></h4>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">20,000 counts resolution</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">0.2% basic accuracy</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Wide LCR ranges with three to five selectable test frequencies (up to 100 kHz for U1733C)</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Auto identification (Ai) automatically determines and displays component type and measurements </span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Detailed component analysis with DCR, ESR, Z, D, Q, and θ functions </span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Battery life of 16 hours/AC-powered </span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">– IR-to-USB connectivity for data logging to PC</span></li>
</ul>
<p>The post <a href="https://rapid-tech.com.au/handheld-lcr-meter-keysight-u1732c-100hz-120hz-1khz-10khz/">Handheld LCR Meter | Keysight U1732C |  100Hz/120Hz/1kHz/10kHz</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>UNI-T UT612 LCR Meter</title>
		<link>https://rapid-tech.com.au/uni-t-ut612-lcr-meter/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sun, 03 May 2020 10:32:00 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=15112</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-14791" src="https://rapid-tech.com.au/wp-content/uploads/2020/03/UNI-T-Logo.png" alt="" width="222" height="58" /></p>
<p><a target="_blank" href="https://mymeter.com.au/product/uni-t-ut612-lcr-meter" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<p>The UNI-T UT612 LCR Meter is used to measure inductance, capacitance and resistance.</p>
<p>Advanced features include series/parallel measurement modes, quality factor/loss/phase angle measurements, equivalent/DC resistance measurements and 5 kinds of measurement frequency in AC mode for selection.</p>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>   <span style="text-decoration: underline;"> <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/05/UNI-T-UT612-Datasheet.pdf" rel="noopener">UNI-T UT612 Datasheet</a></span></h3>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/uni-t-ut612-lcr-meter/">UNI-T UT612 LCR Meter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The UNI-T UT612 LCR Meter meter is designed to accurately measure not only the capacitance, inductance and resistance, but also the ESR of components. This allows the meter to calculate a corresponding quality factor, dissipation and phase angle. The UT612 can perform these measurements at 5 frequencies and the dual display can show two values simultaneously. The main display has 20,000 counts, and the secondary 2000 counts.</p>
<p>The meter can be connected to a computer via USB to log data.</p>
<p>The UNI-T UT612 can be easily operated in production lines, component inspection and electronic maintenance.</p>
<p>Advanced features include series/parallel measurement modes, quality factor/loss/phase angle measurements, equivalent/DC resistance measurements and 5 kinds of measurement frequency in AC mode for selection.</p>
<h3>UNI-T UT612 LCR Meter Specification</h3>
<table style="height: 908px;" border="0" width="559" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td height="16"><strong>Specifications</strong></td>
<td><strong>Range</strong></td>
<td><strong>Accuracy</strong></td>
</tr>
<tr>
<td height="16">Inductance (H)</td>
<td>20uH~2000H</td>
<td>±(0.5%+5)</td>
</tr>
<tr>
<td height="16">Capacitance (F)</td>
<td>200pF~20mF</td>
<td>±(0.5%+5)</td>
</tr>
<tr>
<td height="16">Resistance (Ω)</td>
<td>20Ω~200MΩ</td>
<td>±(0.3%+5)</td>
</tr>
<tr>
<td height="16">Test frequency (Hz)</td>
<td>100Hz/120Hz/1kHz/10kHz/100kHz</td>
<td>√</td>
</tr>
<tr>
<td height="16">Operating voltage</td>
<td>0.6Vrms</td>
<td>√</td>
</tr>
<tr>
<td height="16">Test parameters</td>
<td>L/C/R/DCR/Q/D/θ/ESR</td>
<td>√</td>
</tr>
<tr>
<td colspan="3" height="16"><strong>Features</strong></td>
</tr>
<tr>
<td height="16">Display count</td>
<td></td>
<td>20000</td>
</tr>
<tr>
<td height="16">D/Q display count</td>
<td></td>
<td>2000</td>
</tr>
<tr>
<td height="16">D/Q resolution</td>
<td>0.001</td>
<td>√</td>
</tr>
<tr>
<td height="16">Auto range</td>
<td></td>
<td>√</td>
</tr>
<tr>
<td height="16">Test frequency real-time display</td>
<td></td>
<td>√</td>
</tr>
<tr>
<td height="16">Measurement mode</td>
<td>Series/Parallel</td>
<td>√</td>
</tr>
<tr>
<td height="16">Auto power off</td>
<td></td>
<td>√</td>
</tr>
<tr>
<td height="16">Low battery indication</td>
<td>≤6.8V</td>
<td>√</td>
</tr>
<tr>
<td height="16">Data hold</td>
<td></td>
<td>√</td>
</tr>
<tr>
<td height="16">Relative mode</td>
<td></td>
<td>√</td>
</tr>
<tr>
<td height="16">USB interface</td>
<td></td>
<td>√</td>
</tr>
<tr>
<td height="16">USB interface/PC data records</td>
<td></td>
<td>60000</td>
</tr>
<tr>
<td height="16">LCD backlight</td>
<td></td>
<td>√</td>
</tr>
<tr>
<td height="16">Analog bar graph</td>
<td></td>
<td>26</td>
</tr>
<tr>
<td height="16">Deviation ratio measurement</td>
<td></td>
<td>√</td>
</tr>
<tr>
<td height="16">Comparison function</td>
<td></td>
<td>√</td>
</tr>
<tr>
<td height="16">Calibration function</td>
<td></td>
<td>√</td>
</tr>
<tr>
<td height="16">Output impedance</td>
<td>120Ω</td>
<td>√</td>
</tr>
<tr>
<td height="18">Auto LCR check and measurement</td>
<td></td>
<td>√</td>
</tr>
<tr>
<td colspan="3" height="16"><strong>General Characterisitics</strong></td>
</tr>
<tr>
<td height="16">Power</td>
<td colspan="2">9V battery (6F22) or USB</td>
</tr>
<tr>
<td height="16">Display</td>
<td colspan="2">40mm x 63mm</td>
</tr>
<tr>
<td height="16">Product color</td>
<td colspan="2">Red and grey</td>
</tr>
<tr>
<td height="16">Product net weight</td>
<td colspan="2">374g</td>
</tr>
<tr>
<td height="16">Product size</td>
<td colspan="2">96mm x 193mm x 47mm</td>
</tr>
<tr>
<td height="16">Standard accessories</td>
<td colspan="2">Battery, SMD test clamp, USB interface cable, multi-purpose socket, PC software CD</td>
</tr>
</tbody>
</table>
<p><a href="https://www.uni-trend.com/uploadfile/cloud/Software/Meters-software/UT612.rar"><span style="text-decoration: underline;">Download UT612 Software</span></a></p>
<p>&nbsp;</p>
<p>The post <a href="https://rapid-tech.com.au/uni-t-ut612-lcr-meter/">UNI-T UT612 LCR Meter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Extech LCR200 Passive Component LCR Meter</title>
		<link>https://rapid-tech.com.au/extech-lcr200-passive-component-lcr-meter/</link>
					<comments>https://rapid-tech.com.au/extech-lcr200-passive-component-lcr-meter/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sun, 03 Apr 2016 18:05:49 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=2322</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-1918" src="http://rapid-tech.com.au/wp-content/uploads/2016/03/Extech-logo.jpg" alt="Extech logo" width="200" height="61" /></p>
<p>The Extech LCR200 is useful for manufacturing facilities performing QC and testing, as well as for individual users that need to validate and sort a range of components in custom projects. Unlike the capacitance and resistance capabilities of a digital multimeter, this affordable-yet-advanced meter provides enhanced accuracy and the advantage of inductance. For your circuit testing, the LCR meter enables you to test a range of important secondary parameters such as the Quality, Dissipation, θ (Phase), and Equivalent Series Resistance (ESR) of your components with both series and parallel modes.</p>
<h4>Authorised Australian Distributor</h4>
<p><img class="alignnone size-full wp-image-2451" src="http://rapid-tech.com.au/wp-content/uploads/2016/04/Capture-2.jpg" alt="CE" width="37" height="30" />   <img class="alignnone size-full wp-image-2450" src="http://rapid-tech.com.au/wp-content/uploads/2016/04/1-Year.jpg" alt="1 Year" width="67" height="35" /></p>
<h4>Optional Accessories</h4>
<p><img class="alignnone wp-image-2458" src="http://rapid-tech.com.au/wp-content/uploads/2016/04/LCR-200-Optional-Extras.jpg" alt="LCR 200 Optional Extras" width="350" height="137" /></p>
<p>The post <a href="https://rapid-tech.com.au/extech-lcr200-passive-component-lcr-meter/">Extech LCR200 Passive Component LCR Meter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4>Extech LCR200 Features</h4>
<ul>
<li>The Extech LCR200 measures inductance, capacitance, and resistance</li>
<li>Tests secondary parameters of Q (Quality), D (Dissipation), R (Resistance), θ (Phase), and ESR (Equivalent Series Resistance)</li>
<li>Higher accuracy than DMMs</li>
<li>Built-in test fixture</li>
<li>5 preset test frequencies</li>
<li>Dual display with bargraph</li>
</ul>
<p><strong>Key Functionality</strong></p>
<p>With the Extech LCR200 you can see simultaneous 20,000/2,000 count displays of the primary parameter on the high contrast backlit display coupled with a segmented bargraph display. You can set Hi/Lo limits using absolute values or percentage limits and test with 5 preset frequencies. Open and Short Zero removes unwanted stray impedances from the measurement. Use the built-in test fixture or external test leads (included). You can expand the functionality of your LCR200 with several optional accessories (not included): SMD Component Tweezers (LCR203) and a plug-in SMD Chip Component Fixture (LCR205). A soft pouch storage case (CA900) is also available. The LCR200 has an Auto Power Off function that can also be disabled and a low battery indicator to alert you when to replace the batteries.</p>
<p><strong>Open/Short Calibration</strong></p>
<p>In order to improve the accuracy for high/low impedance measurements , it is recommended to do OPEN/SHORT calibration mode before the measurement. This removes stray impedances in test leads or fixtures.</p>
<ol>
<li>Press the CAL button for greater than 2 seconds to start the open/short calibration procedure:</li>
<li>The “CAL” icon and “OPEN” appear in the display</li>
<li>With no component connected, press the CAL button. The display will count down from 30 and either “PASS” or “FAIL” will appear in the display.</li>
<li>Press the CAL button and “Srt” will appear.</li>
<li>Short the input and press the CAL button. The display will count down from 30 and either “PASS” or “FAIL” will appear in the display.</li>
<li>Press the CAL button to exit the cal mode.</li>
<li>If PASS appeared for both the OPEN and SHORT modes, the calibration data will be saved to external EEPROM.</li>
<li>If FAIL appeared for either calibration, the impedance was too large to zero out and the data is not stored.</li>
</ol>
<h3>Specifications</h3>
<div id="tab-specifications" class="tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom ui-tabs-hide">
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellheader" colspan="2">Specifications</td>
</tr>
<tr>
<td class="speccelltitle" align="center">Display</td>
<td class="speccelldata" align="center">LCD size:66.8 X 52.8 mm. with green backlight</td>
</tr>
<tr>
<td class="speccelltitle" align="center">Test frequency</td>
<td class="speccelldata" align="center">100Hz, 120Hz, 1KHz, 10 KHz, 100KHz</td>
</tr>
<tr>
<td class="speccelltitle" align="center">Dissipation factor</td>
<td class="speccelldata" align="center">0.000 to 1999</td>
</tr>
<tr>
<td class="speccelltitle" align="center">Quality factor</td>
<td class="speccelldata" align="center">0.000 to 1999</td>
</tr>
<tr>
<td class="speccelltitle" align="center">θ measurement</td>
<td class="speccelldata" align="center">± 90°</td>
</tr>
<tr>
<td class="speccelltitle" align="center">Sorting tolerance</td>
<td class="speccelldata" align="center">± 0.25%, ± 0.5%, ± 1%, ± 2%, ± 5% ± 10%, ± 20%, +80% -20%</td>
</tr>
<tr>
<td class="speccelltitle" align="center">Calibration</td>
<td class="speccelldata" align="center">Open/Short calibration</td>
</tr>
<tr>
<td class="speccelltitle" align="center">Data output</td>
<td class="speccelldata" align="center">RS232/USB PC computer interface</td>
</tr>
<tr>
<td class="speccelltitle" align="center">Power off</td>
<td class="speccelldata" align="center">Auto shut off saves battery life or manual off by push button</td>
</tr>
<tr>
<td class="speccelltitle" align="center">Operating temperature</td>
<td class="speccelldata" align="center">0°C to 50°C</td>
</tr>
<tr>
<td class="speccelltitle" align="center">Operating humidity</td>
<td class="speccelldata" align="center">Less then 85% R.H</td>
</tr>
<tr>
<td class="speccelltitle" align="center">Power Supply</td>
<td class="speccelldata" align="center">006P DC 9V battery * Alkaline or Heavy duty type</td>
</tr>
<tr>
<td class="speccelltitle" align="center">Power consumption</td>
<td class="speccelldata" align="center">DC 35 mA approximately</td>
</tr>
<tr>
<td class="speccelltitle" align="center">Dimension</td>
<td class="speccelldata" align="center">193 x 88 x 41mm</td>
</tr>
<tr>
<td class="speccelltitle" align="center">Weight</td>
<td class="speccelldata" align="center">385 g * meter only</td>
</tr>
</tbody>
</table>
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellheader" colspan="3">Electrical Specifications (23± 5 ° C)</td>
</tr>
<tr>
<td class="speccellcategory" colspan="3">DC Resistance</td>
</tr>
<tr>
<td class="speccelltitle" align="center">Range</td>
<td class="speccelltitle" align="center">Accuracy</td>
<td class="speccelltitle" align="center">Remark</td>
</tr>
<tr>
<td class="speccelldata" align="center">20Ω</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center">After calibration</td>
</tr>
<tr>
<td class="speccelldata" align="center">200Ω</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">2kΩ</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">20kΩ</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">200kΩ</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">2MΩ</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center">After calibration</td>
</tr>
<tr>
<td class="speccelldata" align="center">20MΩ</td>
<td class="speccelldata" align="center">± (1.0%rdg + 5digits)</td>
<td class="speccelldata" align="center">After calibration</td>
</tr>
<tr>
<td class="speccelldata" align="center">200MΩ</td>
<td class="speccelldata" align="center">± (2.0%rdg + 5digits)</td>
<td class="speccelldata" align="center">After calibration</td>
</tr>
</tbody>
</table>
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellcategory" colspan="4">AC Resistance</td>
</tr>
<tr>
<td class="speccelltitle" align="center">Range</td>
<td class="speccelltitle" align="center">Accuracy</td>
<td class="speccelltitle" align="center">Accuracy</td>
<td class="speccelltitle" align="center">Remark</td>
</tr>
<tr>
<td class="speccelldata" align="center"></td>
<td class="speccelltitle" align="center">100Hz/120Hz</td>
<td class="speccelltitle" align="center">1000Hz</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">20Ω</td>
<td class="speccelldata" align="center">± (1% + 5digits)</td>
<td class="speccelldata" align="center">± (1%rdg + 5digits)</td>
<td class="speccelldata" align="center">After calibration</td>
</tr>
<tr>
<td class="speccelldata" align="center">200Ω</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">2kΩ</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">20kΩ</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">200kΩ</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">2MΩ</td>
<td class="speccelldata" align="center">± (1.0%rdg + 5digits)</td>
<td class="speccelldata" align="center">± (1.0%rdg + 5digits)</td>
<td class="speccelldata" align="center">After calibration</td>
</tr>
<tr>
<td class="speccelldata" align="center">20MΩ</td>
<td class="speccelldata" align="center">± (1.0%rdg + 5digits)</td>
<td class="speccelldata" align="center">± (2.0%rdg + 5digits)</td>
<td class="speccelldata" align="center">After calibration</td>
</tr>
<tr>
<td class="speccelldata" align="center"></td>
<td class="speccelltitle" align="center">10kHz</td>
<td class="speccelltitle" align="center">100kHz</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">20Ω</td>
<td class="speccelldata" align="center">± (1.0%rdg + 5digits)</td>
<td class="speccelldata" align="center">± (2.0%rdg + 5digits)</td>
<td class="speccelldata" align="center">After calibration</td>
</tr>
<tr>
<td class="speccelldata" align="center">200Ω</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">2kΩ</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">20kΩ</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">200kΩ</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">2MΩ</td>
<td class="speccelldata" align="center">± (1%rdg + 5digits)</td>
<td class="speccelldata" align="center">± (2.0%rdg + 5digits)</td>
<td class="speccelldata" align="center">After calibration</td>
</tr>
<tr>
<td class="speccelldata" align="center">20MΩ</td>
<td class="speccelldata" align="center">± (2.0%rdg + 5digits)</td>
<td class="speccelldata" align="center">&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;</td>
<td class="speccelldata" align="center">After calibration</td>
</tr>
</tbody>
</table>
<p>* If the impedance is larger than 10kΩ, Rp is shown on the display.<br />
* If the impedance is less than 10kΩ, Rs is shown on the display.</p>
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellcategory" colspan="4">Capacitance (Cp/Cs) : D ≦ 0.1</td>
</tr>
<tr>
<td class="speccelltitle" align="center">Range</td>
<td class="speccelltitle" align="center">Accuracy</td>
<td class="speccelltitle" align="center">Accuracy</td>
<td class="speccelltitle" align="center">Remark</td>
</tr>
<tr>
<td class="speccelldata" align="center"></td>
<td class="speccelltitle" align="center">100Hz/120Hz</td>
<td class="speccelltitle" align="center">1000Hz</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">20pF</td>
<td class="speccelldata" align="center">± (2.0%rdg + 5digits)</td>
<td class="speccelldata" align="center">± (1.0%rdg + 5digits)</td>
<td class="speccelldata" align="center">After calibration</td>
</tr>
<tr>
<td class="speccelldata" align="center">200pF</td>
<td class="speccelldata" align="center">± (1.0%rdg + 5digits)</td>
<td class="speccelldata" align="center">± (1.0%rdg + 5digits)</td>
<td class="speccelldata" align="center">After calibration</td>
</tr>
<tr>
<td class="speccelldata" align="center">2000pF</td>
<td class="speccelldata" align="center">± (0.8%rdg + 5digits)</td>
<td class="speccelldata" align="center">± (0.8%rdg + 5digits)</td>
<td class="speccelldata" align="center">After calibration</td>
</tr>
<tr>
<td class="speccelldata" align="center">20nF</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">200nF</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">2000nF</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">20uF</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">200uF</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center">After calibration</td>
</tr>
<tr>
<td class="speccelldata" align="center">2000uF</td>
<td class="speccelldata" align="center">± (1.0%rdg + 5digits)</td>
<td class="speccelldata" align="center">± (1.0%rdg + 5digits)</td>
<td class="speccelldata" align="center">After calibration</td>
</tr>
<tr>
<td class="speccelldata" align="center">20mF</td>
<td class="speccelldata" align="center">± (2.0%rdg + 5digits)</td>
<td class="speccelldata" align="center">&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;</td>
<td class="speccelldata" align="center">After calibration</td>
</tr>
<tr>
<td class="speccelldata" align="center"></td>
<td class="speccelltitle" align="center">10kHz</td>
<td class="speccelltitle" align="center">100kHz</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">20pF</td>
<td class="speccelldata" align="center">± (1.0%rdg + 5digits)</td>
<td class="speccelldata" align="center">± (1.0%rdg + 5digits)</td>
<td class="speccelldata" align="center">After calibration</td>
</tr>
<tr>
<td class="speccelldata" align="center">200pF</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center">± (0.5%rdg+ 5digits)</td>
<td class="speccelldata" align="center">After calibration</td>
</tr>
<tr>
<td class="speccelldata" align="center">2000pF</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center">± (0.5%rdg+ 5digits)</td>
<td class="speccelldata" align="center">After calibration</td>
</tr>
<tr>
<td class="speccelldata" align="center">20nF</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center">± (0.5%rdg+ 5digits)</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">200nF</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center">± (0.5%rdg+ 5digits)</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">2000nF</td>
<td class="speccelldata" align="center">± (0.5%rdg + 5digits)</td>
<td class="speccelldata" align="center">± (0.5%rdg+ 5digits)</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">20uF</td>
<td class="speccelldata" align="center">± (0.8%rdg + 5digits)</td>
<td class="speccelldata" align="center">± (0.8%rdg+ 5digits)</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">200uF</td>
<td class="speccelldata" align="center">± (1.0%rdg + 5digits)</td>
<td class="speccelldata" align="center">&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;</td>
<td class="speccelldata" align="center"></td>
</tr>
</tbody>
</table>
<p>* If the impedance is larger than 10kΩ, Cp is shown on the display.<br />
* If the impedance is less than 10kΩ, Cs is shown on the display.</p>
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellcategory" colspan="4">Inductance (Lp/Ls) : D ≦ 0.1</td>
</tr>
<tr>
<td class="speccelltitle" align="center">Range</td>
<td class="speccelltitle" align="center">Accuracy</td>
<td class="speccelltitle" align="center">Accuracy</td>
<td class="speccelltitle" align="center">Remark</td>
</tr>
<tr>
<td class="speccelldata" align="center"></td>
<td class="speccelltitle" align="center">100Hz/120Hz</td>
<td class="speccelltitle" align="center">1000Hz</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">20uH</td>
<td class="speccelldata" align="center">± (1% + 5d)</td>
<td class="speccelldata" align="center">± (1% + 5d)</td>
<td class="speccelldata" align="center">After calibration</td>
</tr>
<tr>
<td class="speccelldata" align="center">200uH</td>
<td class="speccelldata" align="center">± (1% + 5d)</td>
<td class="speccelldata" align="center">± (1% + 5d)</td>
<td class="speccelldata" align="center">After calibration</td>
</tr>
<tr>
<td class="speccelldata" align="center">2000uH</td>
<td class="speccelldata" align="center">± (0.8% + 5d)</td>
<td class="speccelldata" align="center">± (0.8% + 5d)</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">20mH</td>
<td class="speccelldata" align="center">± (0.5% + 5d)</td>
<td class="speccelldata" align="center">± (0.5% + 5d)</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">200mH</td>
<td class="speccelldata" align="center">± (0.5% + 5d)</td>
<td class="speccelldata" align="center">± (0.5% + 5d)</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">2000mH</td>
<td class="speccelldata" align="center">± (0.5% + 5d)</td>
<td class="speccelldata" align="center">± (0.5% + 5d)</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">20H</td>
<td class="speccelldata" align="center">± (0.5% + 5d)</td>
<td class="speccelldata" align="center">± (0.5% + 5d)</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">200H</td>
<td class="speccelldata" align="center">± (0.5% + 5d)</td>
<td class="speccelldata" align="center">± (0.8% + 5d)</td>
<td class="speccelldata" align="center">After calibration</td>
</tr>
<tr>
<td class="speccelldata" align="center">2000H</td>
<td class="speccelldata" align="center">± (1% + 5d)</td>
<td class="speccelldata" align="center">&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;</td>
<td class="speccelldata" align="center">After calibration</td>
</tr>
<tr>
<td class="speccelldata" align="center"></td>
<td class="speccelltitle" align="center">10kHz</td>
<td class="speccelltitle" align="center">100khz</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">20uH</td>
<td class="speccelldata" align="center">± (1% + 5d)</td>
<td class="speccelldata" align="center">± (1% + 5d)</td>
<td class="speccelldata" align="center">After calibration</td>
</tr>
<tr>
<td class="speccelldata" align="center">200uH</td>
<td class="speccelldata" align="center">± (0.8% + 5d)</td>
<td class="speccelldata" align="center">± (0.8% + 5d)</td>
<td class="speccelldata" align="center">After calibration</td>
</tr>
<tr>
<td class="speccelldata" align="center">2000uH</td>
<td class="speccelldata" align="center">± (0.5% + 5d)</td>
<td class="speccelldata" align="center">± (0.5% + 5d)</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">20mH</td>
<td class="speccelldata" align="center">± (0.5% + 5d)</td>
<td class="speccelldata" align="center">± (0.5% + 5d)</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">200mH</td>
<td class="speccelldata" align="center">± (0.5% + 5d)</td>
<td class="speccelldata" align="center">&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;</td>
<td class="speccelldata" align="center"></td>
</tr>
<tr>
<td class="speccelldata" align="center">2000mH</td>
<td class="speccelldata" align="center">± (0.5% + 5d)</td>
<td class="speccelldata" align="center">&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;</td>
<td class="speccelldata" align="center"></td>
</tr>
</tbody>
</table>
<p>* If the impedance is larger than 10kΩ, Lp is shown on the display.<br />
* If the impedance is less than 10kΩ, Ls is shown on the display.</p>
<p>&nbsp;</p>
</div>
<p>The post <a href="https://rapid-tech.com.au/extech-lcr200-passive-component-lcr-meter/">Extech LCR200 Passive Component LCR Meter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/extech-lcr200-passive-component-lcr-meter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Reed R5001 LCR Meter</title>
		<link>https://rapid-tech.com.au/reed-r5001-lcr-meter/</link>
					<comments>https://rapid-tech.com.au/reed-r5001-lcr-meter/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Sun, 14 Feb 2016 15:11:48 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/reed-r5001-lcr-meter/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-980" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/reed-logo-red.jpg" alt="reed logo red" width="120" height="50" /></p>
<p>The Reed R5001 LCR meter with Data Hold and Autoranging operation for AC impedance and DE resistance measurement feature allowing you to conduct Inductance (F=1kHz) and Resistance (F=1kHz) tests.</p>
<h4>Reed R5001 Features:</h4>
<ul class="gkCircle2">
<li>Measure inductance/capacitance/resistance with secondary parameters including dissipation<br />
factor (D), quality factor (Q), phase angle (Ø), equivalent series/parallel resistance (ESR or Rp)</li>
<li>Autoranging operation for AC impedance and DE resistance measurement</li>
<li>Auto LCR smart check and measurement</li>
<li>Series/Parallel modes</li>
<li>Ls/Lp/Cp with D/Q/Ø/ESR parameters</li>
<li>Support DCR mode 200 to 200MΩ</li>
<li>High accuracy with 4 or 5 terminal Kelvin measurement</li>
<li>Testing frequency is up to 10kHz and output frequency is up to 100kHz</li>
<li>Dual display with backlight</li>
<li>Data hold function</li>
<li>Low battery indication with auto power off</li>
<li>Dust and waterproof to IP67</li>
<li>Includes test leads and batteries.</li>
</ul>
<p><strong>Authorised Australian Distributor</strong></p>
<p><img class="alignnone  wp-image-2716" src="http://rapid-tech.com.au/wp-content/uploads/2016/03/1-Year-Warranty.jpg" alt="1 Year Warranty" width="106" height="63" /></p>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/reed-r5001-lcr-meter/">Reed R5001 LCR Meter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4 class="title">How to use Reed R5001 Data hold LCR meter</h4>
<p>&nbsp;</p>
<p><strong>Test Frequency Functions</strong><br />
When <strong>measuring capacitance</strong>, commonly a 1kHz test frequency is used to measure capacitors that are 0.01μF or smaller. For capacitors that are 10μF or larger, a lower frequency of 120Hz is used. Based on this settings, a high-test frequencies are best for testing very low capacitance components. For large capacitance components, low frequency would be optimal.</p>
<p>When you use this instrument for <strong>measuring inductance</strong>inductors below 2 mH should be measured at 1kHz frequency while inductors above 200H should be measured at 120Hz.</p>
<p><strong>Test Frequency Select</strong><br />
The test frequency can affect the accuracy of the results depending on what frequency is selected and what type and value of a component is being measured or tested. The meter has five test frequencies: 100Hz/120Hz/1kHz/10kHz/100kHz. To set the <strong>&#8220;Test Frequency&#8221;</strong>press the Frequency Button to scroll through the five frequencies sequentially.</p>
<p><strong>Primary Impedance with Secondary Parameter Test</strong><br />
&#8220;Auto-LCR Mode&#8221;, will check the type of impedance and automatically. To switch from &#8220;Auto-LCR&#8221; Mode to &#8220;Auto-&#8220;L Mode, &#8220;Auto-C&#8221; Mode, &#8220;Auto-R&#8221; Mode, and &#8220;DCR&#8221; Mode, Press the Function Button. When Auto-L or Auto-C Mode are selected, the impedance measurement is auto ranging.The Reed R5001&#8217;s primary LCD display will show the inductance or capacitance of DUT (device under test); the secondary LCD display will show the quality or dissipation factor. Press the Secondary Display/Left Button to display the D/Q/ θ/ESR value. When Auto-R (ACR mode) or DCR mode is selected the secondary parameter is omitted.</p>
<p><strong>Series or Parallel Functions</strong><br />
Most <strong>capacitance measurements</strong> will obtain best results with parallel mode selected. Most <strong>inductance measurements</strong> will obtain best results with series mode selected.</p>
<p><strong>Series/Parallel Measurements</strong><br />
When any L/C/R function is selected, the default measurement will be automatically selected. If the impedance is greater than 10kΩ, the meter will select the parallel mode and “Lp/Cp/Rp” icon will be displayed on the LCD screen. The meter will automatically select the &#8220;series mode&#8221; in case of 10kΩ less impedance. “Ls/ Cs/Rs” icon will display on the LCD. You can set the impedance measurement in series mode or in parallel mode sequentially by pressing the Parallel/Series/Right Button.</p>
<p><strong>Data Hold</strong><br />
Press the Hold Button to activate data hold function and &#8220;freeze&#8221; the current measurement on the display. Press the Hold Button again to deactivate it.</p>
<p><strong>Relative mode</strong><br />
This function able you to reserve the current DUT readings (DCUR) on the primary display as a reference value (DREF). To activate this, press the Relative/Down Button.The secondary display will show the percentage of the relative value (REL%). Press the Relative/ Down Button again to show the reference value (DREF) on the primary display;The percentage range is -99.9% to 99.9%. When the relative value is larger than double the reference value (DREF), the symbol “OL%” will appear on the secondary display.</p>
<h4>REED R5001 Specifications</h4>
<table class="table table-striped">
<tbody>
<tr>
<td colspan="2"><strong>Inductance (F=1kHz)</strong></td>
</tr>
<tr>
<td>Range</td>
<td>2000.0µH<br />
20.000/200.0/2000.0mH<br />
20.000/200.00/2000.0H</td>
</tr>
<tr>
<td>Resolution</td>
<td>0.1/1µH<br />
0.01/0.1/1mH<br />
0.01/1H</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±(1.5% +15 dgt.)</td>
</tr>
<tr>
<td colspan="2"><strong>Capacitance (F=1kHz)</strong></td>
</tr>
<tr>
<td>Range</td>
<td>2000.0pF<br />
20.000/200.00/2000.0nF<br />
20.00/200.00/2000µF</td>
</tr>
<tr>
<td>Resolution</td>
<td>0.01/0.1/1pF<br />
0.01/0.1/1nF<br />
0.1µF</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±(1.0% +10 dgt.)</td>
</tr>
<tr>
<td colspan="2"><strong>Resistance (F=1kHz)</strong></td>
</tr>
<tr>
<td>Range</td>
<td>20.000/200.00Ω<br />
2.0000/20.000/200.00kΩ<br />
2.0000/20.000/200.0MΩ</td>
</tr>
<tr>
<td>Resolution</td>
<td>0.01/0.1/1Ω<br />
0.01/0.1/1kΩ<br />
0.1MΩ</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±(1.5% +5 dgt.)</td>
</tr>
<tr>
<td colspan="2"><strong>General Specifications</strong></td>
</tr>
<tr>
<td>Test Frequencies</td>
<td>100/120/1k Hz<br />
10k Hz<br />
100k Hz</td>
</tr>
<tr>
<td>Test Signal Level</td>
<td>0.5V AC RMS typical</td>
</tr>
<tr>
<td>Power Supply</td>
<td>6 x 1.5V AA batteries</td>
</tr>
<tr>
<td>Dimensions</td>
<td>220 x 96 x 60mm</td>
</tr>
<tr>
<td>Weight</td>
<td>360g</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/reed-r5001-lcr-meter/">Reed R5001 LCR Meter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/reed-r5001-lcr-meter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
