<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>HT ITALIA Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/product-tag/ht-italia/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/product-tag/ht-italia/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Mon, 03 Aug 2026 04:32:43 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.7</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>HT ITALIA Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/product-tag/ht-italia/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>HT Italia PQA924 Power and Energy Quality Analyzer &#8211; Class S, Advanced Auto-Configuration, 3180 Channel Recording, IEC/EN61000-4-30 Compliance</title>
		<link>https://rapid-tech.com.au/ht-italia-pqa924-power-and-energy-quality-analyzer/</link>
					<comments>https://rapid-tech.com.au/ht-italia-pqa924-power-and-energy-quality-analyzer/#respond</comments>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Sun, 16 Mar 2025 22:33:53 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=1117882</guid>

					<description><![CDATA[<h4><img class="alignnone wp-image-1117854" src="https://rapid-tech.com.au/wp-content/uploads/2025/03/HT_Italia-Logo.png" alt="" width="152" height="50" /></h4>
<p><a target="_blank" href="https://mymeter.com.au/product/ht-italia-pqa924-power-and-energy-quality-analyzer" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<p class="ai-optimize-13">The HT Italia PQA924 Power and Energy Quality Analyzer is a reliable tool for accurate power quality analysis.</p>
<p class="ai-optimize-14">Designed with Class S accuracy and advanced auto-configuration, it simplifies the process for professionals. Key features include 3180-channel recording, harmonic analysis, and fast voltage transient detection, making it ideal for troubleshooting electrical systems and ensuring compliance with IEC/EN61000-4-30 standards.</p>
<p>With its intuitive software and precise measurements, this energy analyzer is the perfect tool for power monitoring, energy efficiency, and system optimisation. It also supports remote monitoring via Ethernet using the Agora Software.</p>
<p class="ai-optimize-16"><img class="alignnone size-full wp-image-19718" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" /> <a href="https://rapid-tech.com.au/wp-content/uploads/2025/03/HT-PQA-924-Datasheet.pdf">HT PQA-924 Datasheet</a></p>
<p class="ai-optimize-17"><img class="alignnone size-full wp-image-19718" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" /> <a href="https://rapid-tech.com.au/wp-content/uploads/2025/03/HT-PQA-924.pdf">HT PQA-924</a></p>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/ht-italia-pqa924-power-and-energy-quality-analyzer/">HT Italia PQA924 Power and Energy Quality Analyzer &#8211; Class S, Advanced Auto-Configuration, 3180 Channel Recording, IEC/EN61000-4-30 Compliance</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 class="font-bold text-h3 leading-[40px] pt-[21px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]" dir="ltr">HT Italia PQA924 Power and Energy Quality Analyzer &#8211; Class S</h2>
<h3 class="font-bold text-h4 leading-[30px] pt-[15px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]" dir="ltr">Simplify Advanced Power Quality Analysis</h3>
<p class="text-body font-regular leading-[24px] pt-[9px] pb-[2px]" dir="ltr">The <b><strong class="font-bold">HT Italia PQA924 Power and Energy Quality Analyzer (Class S)</strong></b> is the ultimate tool for professionals who need accuracy, efficiency, and reliability in power quality analysis and troubleshooting. Designed with cutting-edge technology and a user-friendly interface, the <b><strong class="font-bold">PQA924 analyzer</strong></b> makes even complex power quality studies simple and precise.</p>
<p class="text-body font-regular leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Fully compliant with <b><strong class="font-bold">IEC/EN61000-4-30</strong></b> standards, this analyzer delivers <b><strong class="font-bold">high-accuracy Class S measurements</strong></b>, making it the ideal solution for analyzing single-phase or three-phase systems. Whether you&#8217;re diagnosing voltage dips, harmonic issues, or power interruptions, the <b><strong class="font-bold">HT Italia PQA924</strong></b> has the tools and features to meet your needs.</p>
<hr />
<h3 class="font-bold text-h4 leading-[30px] pt-[15px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]" dir="ltr">Key Features of the HT Italia PQA924</h3>
<h4 class="font-bold text-body leading-[24px] pt-[12px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]" dir="ltr">1. High-Performance Data Recording</h4>
<ul class="pt-[9px] pb-[2px] pl-[24px] list-inside list-disc pt-[5px]">
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="1">Record up to <b><strong class="font-bold">3180 channels</strong></b> of data, including voltage-current events.</li>
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="2">Analyze <b><strong class="font-bold">386 network parameters</strong></b> such as frequency, voltage, current, and power.</li>
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="3">Perform <b><strong class="font-bold">harmonics analysis</strong></b> with up to <b><strong class="font-bold">2225 data points</strong></b> for voltages and currents.</li>
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="4">Monitor <b><strong class="font-bold">24 energy channels</strong></b> for active and reactive energy data.</li>
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="5">Detect voltage anomalies like dips, swells, and interruptions with <b><strong class="font-bold">10ms resolution</strong></b>.</li>
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="6">Capture fast voltage transients with <b><strong class="font-bold">1μs resolution</strong></b> for detailed analysis.</li>
</ul>
<h4 class="font-bold text-body leading-[24px] pt-[12px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]" dir="ltr">2. Comprehensive Power Quality Insights</h4>
<ul class="pt-[9px] pb-[2px] pl-[24px] list-inside list-disc pt-[5px]">
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="1">Analyze voltage and current harmonics up to the <b><strong class="font-bold">63rd order</strong></b> with THD% calculations.</li>
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="2">Detect <b><strong class="font-bold">inrush currents</strong></b>, perfect for electric motor diagnostics.</li>
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="3">Measure active, reactive, and apparent power and energy.</li>
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="4">Identify phase sequence and unbalance issues in three-phase systems.</li>
</ul>
<h4 class="font-bold text-body leading-[24px] pt-[12px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]" dir="ltr">3. Advanced Auto-Configuration (AUTOSET)</h4>
<ul class="pt-[9px] pb-[2px] pl-[24px] list-inside list-disc pt-[5px]">
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="1">Automatically detects current transducers to prevent connection errors.</li>
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="2">Corrects reversed clamp connections instantly for accurate readings.</li>
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="3">Eliminates wiring errors, saving you time and ensuring reliable results.</li>
</ul>
<h4 class="font-bold text-body leading-[24px] pt-[12px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]" dir="ltr">4. Robust Data Management</h4>
<ul class="pt-[9px] pb-[2px] pl-[24px] list-inside list-disc pt-[5px]">
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="1">Store data on a convenient <b><strong class="font-bold">32GB removable memory card</strong></b>.</li>
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="2">Transfer data via <b><strong class="font-bold">USB, Ethernet, or Wi-Fi</strong></b> for easy access.</li>
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="3">Use the <b><strong class="font-bold">HTAgorà software</strong></b> to analyze data and create professional reports.</li>
</ul>
<hr />
<h3 class="font-bold text-h4 leading-[30px] pt-[15px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]" dir="ltr">Why Choose the HT Italia PQA924?</h3>
<p class="text-body font-regular leading-[24px] pt-[9px] pb-[2px]" dir="ltr">The <b><strong class="font-bold">HT Italia PQA924 Power and Energy Quality Analyzer</strong></b> is an essential tool for power quality professionals. Its advanced features, including a <b><strong class="font-bold">color touch screen display</strong></b>, <b><strong class="font-bold">Class S accuracy</strong></b>, and innovative <b><strong class="font-bold">AUTOSET technology</strong></b>, make it reliable and easy to use.</p>
<p class="text-body font-regular leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Whether you&#8217;re troubleshooting voltage anomalies, monitoring harmonics, or capturing inrush currents, the <b><strong class="font-bold">PQA924 analyzer</strong></b> delivers exceptional performance every time.</p>
<hr />
<h3 class="font-bold text-h4 leading-[30px] pt-[15px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]" dir="ltr">Popular Applications</h3>
<ul class="pt-[9px] pb-[2px] pl-[24px] list-inside list-disc pt-[5px]">
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="1">Conducting <b><strong class="font-bold">power quality studies</strong></b> in industrial, commercial, or residential systems.</li>
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="2">Diagnosing voltage dips, swells, interruptions, and electrical imbalances.</li>
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="3">Monitoring harmonics and interharmonics for improved system efficiency.</li>
<li class="text-body font-regular leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="4">Capturing <b><strong class="font-bold">fast voltage transients</strong></b> and identifying inrush current events.</li>
</ul>
<hr />
<h3 class="font-bold text-h4 leading-[30px] pt-[15px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]" dir="ltr">Upgrade Your Power Quality Analysis Today</h3>
<p class="text-body font-regular leading-[24px] pt-[9px] pb-[2px]" dir="ltr">The <b><strong class="font-bold">HT Italia PQA924 Power and Energy Quality Analyzer</strong></b> combines <b><strong class="font-bold">accuracy</strong></b>, <b><strong class="font-bold">ease of use</strong></b>, and <b><strong class="font-bold">advanced technology</strong></b> in one powerful device. Whether you&#8217;re an engineer, technician, or energy professional, this analyzer is designed to meet your needs and exceed your expectations.</p>
<p class="text-body font-regular leading-[24px] pt-[9px] pb-[2px]" dir="ltr"><b><strong class="font-bold">Order the HT Italia PQA924 today</strong></b> and elevate your power quality analysis with precision and confidence!</p>
<p>The post <a href="https://rapid-tech.com.au/ht-italia-pqa924-power-and-energy-quality-analyzer/">HT Italia PQA924 Power and Energy Quality Analyzer &#8211; Class S, Advanced Auto-Configuration, 3180 Channel Recording, IEC/EN61000-4-30 Compliance</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/ht-italia-pqa924-power-and-energy-quality-analyzer/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HTI EV-TEST100 EVSE Adapter for Electric Vehicle Charger Testing</title>
		<link>https://rapid-tech.com.au/hti-ev-test100-evse-adapter-for-electric-vehicle-charger-testing/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Fri, 25 Sep 2020 07:09:21 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=16640</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/10/HTI-Auth-Med.jpg"><img class="alignnone size-full wp-image-5688" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/HTI-Auth-Med.jpg" alt="" width="165" height="120" /></a></p>
<p>The EV-TEST100 is a 1- and 3-phase test adapter with type 2 connector for simulation of charge levels and to check the effectiveness of protective measures at e-charging stations for electric cars (EVSE systems - Electrical Vehicle Supply Equipment)</p>
<p>The EV-TEST100 in combination with appropriate HT multifunction instrument simulates an electric vehicle connected to the charging station, allowing you to verify the EVSE full functionality and electrical safety.</p>
<p>EV-TEST100 is able to test charging stations with charging modes 2 and 3 and Type 2 connector (European standard).</p>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/hti-ev-test100-evse-adapter-for-electric-vehicle-charger-testing/">HTI EV-TEST100 EVSE Adapter for Electric Vehicle Charger Testing</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3 style="text-align: center;">HTI EV-TEST100 EVSE Adapter for Electric Vehicle Charger Testing<br />
<iframe src="https://www.youtube.com/embed/EPVzSR1h_MQ" width="506" height="285" frameborder="0" allowfullscreen="allowfullscreen"></iframe></h3>
<div>The EV-Test100 was specially developed as an accessory for testing e-charging stations.</div>
<div>It can be used to simulate charge states and to check the effectiveness of protective measures at type 3 e-charging stations with a type 2 connector.</div>
<div>The simple handling in combination with the Combi G3 or Combi G2 is guaranteed.</div>
<h3>Measurement functions</h3>
<ul>
<li>Universal 4mm sockets for connection to a 1- or 3-phase installation tester using test leads (banana plugs)</li>
<li>Separate phase display with three LEDs for easy voltage checking</li>
<li>Proximity Pilot (PP) rotary switch for simulating different current carrying capacities of charging cables</li>
<li>Control Pilot (CP) rotary switch for simulating the electrical vehicle status A, B, C D</li>
<li>Rotary switch error to simulate a short circuit between CP and PE (state E = error)</li>
<li>Simulation of PE fault (ground fault)</li>
<li>Connection for the CP signal output to check communication between the adapter (= simulated electric vehicle) and the charging station</li>
<li>Type 2 plug for connection to the charging station even with a permanently connected charging cable</li>
<li>Vehicle simulation (CP): The various vehicle states A to D can be simulated using a rotary switch (according to IEC 61851)</li>
<li>Cable simulation (PP): The various codings for charging cables with 13, 20, 32 and 63 A as well as “no cable connected” can be simulated using a rotary switch</li>
<li>Error simulation: Simulation of a short circuit between CP and PE using a rotary switch (state E = error)</li>
<li>Display of phase voltages via LEDs</li>
<li>Testing of e-charging stations even with a permanent</li>
<li>connected charging cable</li>
<li>For vehicle simulation (CP):</li>
</ul>
<h4><strong>According to IEC 61851, the states A, B, C, D and E can be simulated. The various vehicle states are set using the rotary switch.</strong></h4>
<div style="padding-left: 40px;">State A: no vehicle connected</div>
<div style="padding-left: 40px;">Condition B: Vehicle connected but not ready for charging</div>
<div style="padding-left: 40px;">Condition C: Vehicle connected and ready for charging, ventilation of the charging area not required</div>
<div style="padding-left: 40px;">Condition D: Vehicle connected and ready for charging, ventilation of the charging area required</div>
<div style="padding-left: 40px;">State E: Error: Short circuit CP-PE via internal diode</div>
<div></div>
<div><strong>For cable simulation (PP):</strong></div>
<div>The different coding for charging cables with 13, 20, 32 and 63 A can be simulated. It is also possible to simulate the -no cable- state. The different charging cables are simulated by switching different resistors between PP and PE using the rotary switch. According to IEC 61851, the following values ​​are possible:</div>
<div></div>
<div style="padding-left: 40px;">No cable: ∞ Ohm</div>
<div style="padding-left: 40px;">13 A cable: 1.5 k Ohm</div>
<div style="padding-left: 40px;">20 A cable: 680 Ohm</div>
<div style="padding-left: 40px;">32 A cable: 220 Ohm</div>
<div style="padding-left: 40px;">63 A cable. 100 ohms</div>
<div></div>
<div class="pg-opt prodotti">
<div class="container-fluid">
<div class="row">
<div class="col-md-12 bg-greyprod">
<section class="slice ">
<div class="container">
<div class="tab-content">
<div id="tab-2" class="tab-pane fade active in">
<div class="tab-body prodotti">
<h3 class="titlethin funz">HTI EV-TEST100 Functions</h3>
<div class="list-check">
<table border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i> Use for EVSE charging stations</td>
<td class="description">Charging modes 2 and 3</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Test cable with connector</td>
<td class="description">Type 2 (IEC 62196-2)</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Vehicle simulation via Control Pilot (CP state)</td>
<td class="description">States A, B, C, D</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Simulating the current capacity of Proximity Pilot (PP state)</td>
<td class="description">NC, 13A, 30A, 32A, 63A</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Fault condition simulation on PE</td>
<td class="description">FAULT PE</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Diode simulation in short circuit</td>
<td class="description">FAULT E</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>EVSE internal counter efficiency check</td>
<td class="description">LOAD</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Input voltage</td>
<td class="description">Max 415V AC, Phase-Phase, 50 / 60Hz</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>External load L-N-PE</td>
<td class="description">240V 50/60Hz, Max 10A AC</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>CP signal</td>
<td class="description">PWM 12V</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>External load protection</td>
<td class="description">Fuse FF 10A / 250V, 5x20mm</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Operating temperature</td>
<td class="description">0°C ÷ 40°C</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Operating humidity</td>
<td class="description">&lt;80&amp;RH</td>
</tr>
</tbody>
</table>
</div>
<h4 class="titlethin norm">Guidelines</h4>
<div class="row">
<div class="col-sx-12 col-md-12 col-lg-12">
<div class="col-sx-12 col-md-12 col-lg-12 nopadding_right nopadding_left">
<ul>
<li><i class="fa fa-check"></i> IEC/EN60364-7-722</li>
</ul>
</div>
<div class="col-sx-12 col-md-12 col-lg-12 nopadding_right nopadding_left">
<ul>
<li><i class="fa fa-check"></i> IEC/EN61010-1</li>
</ul>
</div>
<div class="col-sx-12 col-md-12 col-lg-12 nopadding_right nopadding_left">
<ul>
<li> IEC/EN61851-1</li>
</ul>
</div>
<h4>EV-TEST100 can only be used in combination with the following master models of the HT family</h4>
<p style="padding-left: 40px;">COMBI G3 MET-5035M<br />
COMBIG2 COMBIG2PLUS<br />
MACROTOUCH<br />
COMBITEST425<br />
MT-300<br />
MFT-PRO<br />
COMBITOUCH<br />
COMBIG3<br />
<span style="font-size: 85%;">(*) The list of available models is subject to change without notice. </span></p>
</div>
</div>
</div>
</div>
</div>
</div>
</section>
</div>
</div>
</div>
</div>
<p>The post <a href="https://rapid-tech.com.au/hti-ev-test100-evse-adapter-for-electric-vehicle-charger-testing/">HTI EV-TEST100 EVSE Adapter for Electric Vehicle Charger Testing</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HT Instruments FULLTEST3 Professional Multifunction Safety Tester</title>
		<link>https://rapid-tech.com.au/ht-instruments-fulltest3-professional-multifunction-safety-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Fri, 28 Aug 2020 02:34:17 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=16399</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/10/HTI-Auth.jpg"><img class="alignnone size-full wp-image-5689" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/HTI-Auth.jpg" alt="" width="220" height="160" /></a></p>
<p><a target="_blank" href="https://mymeter.com.au/product/ht-instruments-fulltest3-professional-multifunction-safety-tester" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<p>[button size="medium" style="secondary" text="<b>RENT BEFORE YOU BUY</b>" link="https://rentmymeter.com.au/product/ht-instruments-fulltest3-professional-multifunction-safety-tester/" target="blank"]</p>
<p><span style="font-size: 110%;"><strong>The HT Instruments FULLTEST3 effects all tests required by IEC/EN60204-1:2006 and IEC/EN61439 in a simple, reliable and fast way.</strong></span></p>
<p>The FULLTEST3 also carries out a considerable number of safety tests that makes it as a flexible solution also in compliance with other standards.</p>
<p>Besides continuity of protection conductors, insulation and withstanding, FULLTEST3 tests type A, AC, and B general, selective and delayed RCDs, curve B, C, D, and K MCBs and type gG and aM fuses, line/fault impedance with standard or high resolution, non-trip earth loop impedance, leakage current, etc.</p>
<p>FULLTEST3 is provided with innovative interfaces such as a colour touch-screen graphical display, 3 USB ports for PC connection, a USB memory stick, a USB printer and bar code readers.</p>
<p style="text-align: center;"><span style="font-size: 110%;"><strong>The FULLTEST3 is the ideal partner for designers, manufacturers and installers.</strong></span></p>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST3-Datasheet.pdf" rel="noopener">HT FULLTEST3 Datasheet</a></span></h3>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST3-Brochure.pdf" rel="noopener">HT FULLTEST3 Brochure</a></span></h3>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST3-User-Manual.pdf" rel="noopener">HT FULLTEST3 User Manual</a></span></h3>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/ht-instruments-fulltest3-professional-multifunction-safety-tester/">HT Instruments FULLTEST3 Professional Multifunction Safety Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><b>FULLTEST 3 is the Most Advanced Solution for a Complete Compliance with the Actual Guidelines</b></p>
<div class="epyt-video-wrapper"><iframe  id="_ytid_77888"  width="1020" height="574"  data-origwidth="1020" data-origheight="574"  data-relstop="1" src="https://www.youtube.com/embed/alEBhWBmBJA?enablejsapi=1&#038;autoplay=0&#038;cc_load_policy=0&#038;cc_lang_pref=&#038;iv_load_policy=1&#038;loop=0&#038;rel=0&#038;fs=1&#038;playsinline=1&#038;autohide=2&#038;theme=dark&#038;color=red&#038;controls=1&#038;disablekb=0&#038;" class="__youtube_prefs__  epyt-is-override  no-lazyload" title="HT FULLTEST3 Tutorials - Prova di Rigidità Dielettrica fino a 5100VAC (ITA)"  allow="fullscreen; accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen data-no-lazy="1" data-skipgform_ajax_framebjll=""></iframe></div>
<p>Multifunction Tester for safety of machinery IEC/EN60204-1:2016 and low voltage switchgears and controlgears IEC/EN61439-1-2:2011</p>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST5-Front-Panel.jpg"><img fetchpriority="high" decoding="async" class="aligncenter wp-image-16402" src="https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST5-Front-Panel-300x213.jpg" alt="" width="500" height="355" srcset="https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST5-Front-Panel-300x213.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST5-Front-Panel-600x425.jpg 600w, https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST5-Front-Panel-768x545.jpg 768w, https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST5-Front-Panel.jpg 1000w" sizes="(max-width: 500px) 100vw, 500px" /></a></p>
<p><strong>IEC/EN60204-1:2016 Measuments:</strong></p>
<p><strong>Power Frequency Dielectric withstand voltage</strong> with test voltage of <strong>1000VAC</strong></p>
<p><strong>Testing protection against indirect contact:</strong></p>
<ul>
<li>Continuity of protective conductors with test current 200mA</li>
<li>Automatic disconnection of the supply (RCD, MCB, Fuse)​</li>
<li>RCD tripping (RCD AC, A, B) up to 1A on TT Systems</li>
<li>Magneto-thermal protections (MCB curve verificaiton on B, C, D, K) and fuses (gG, aM) on TN Systems</li>
</ul>
<p><strong>​Insulation resistance measurement with test voltage of 500VDC</strong></p>
<p><strong>Discharging of residual voltage V&lt;60V in 5sec/1sec</strong></p>
<p><strong>IEC/EN61439-1-2:2011 Measurements:</strong></p>
<p><strong>Clearances and Creepage distances:</strong></p>
<ul>
<li>Dielectric withstand voltage with test voltage of up to 3400/5100VAC</li>
</ul>
<p><strong>Continuity of earth system and protective conductors</strong> ≥10A</p>
<p><strong>Power Frequency Dielectric withstand voltage</strong> with test voltage of <strong>1800VAC</strong></p>
<p><strong>Alternative power-frequency voltage test up to 5100VAC</strong></p>
<p><strong>Test on enclosures of insulating material:</strong></p>
<ul>
<li><strong>​</strong>Dielectric Withstand voltage with test voltage up to <strong>2835V</strong></li>
</ul>
<p><strong>Discharging of residual voltage V&lt;60V in 5sec/1sec</strong></p>
<p>FULLTEST3 is designed to satisfy the requirements of the IEC/EN60204-1:2006 guideline (electrical equipment of industrial machines) and for the new series of prescriptions relative to the IEC/EN61439-1 guideline (Switchgear panels). This last guideline require, among other tests, the Dielectric tests with a test voltage up to 5100V!</p>
<h3><strong>FULLTEST3 Features:</strong></h3>
<ul>
<li>Continuity of protection conductors with 200mA</li>
<li>Continuity of protection conductors with I&gt;10A, V&lt;12V AC</li>
<li>Continuity of protection conductors with I&gt;25A, V&lt;12V AC</li>
<li>Insulation Resistance with 100,250,500,1000VDC test voltage</li>
<li>Withstanding test with test voltage programmable from 250V to 5100V AC</li>
<li>Discharging time test on internal capacitance and on power supply plug</li>
<li>Leakage/absorbed and power on the test socket</li>
<li>Leakage current with external clamp (HT96U optional accessories)</li>
<li>Test on RCDs type A, AC, B General, Selective, Delayed up to 1000mA</li>
<li>Line/Loop impedance and Ipsc calculation</li>
<li>Line/Loop impedance with high resolution (with IMP57 optional accessories)</li>
<li>Test on MCB protection with curve B, C, D, K and Fuse type gG and aM</li>
<li>Selection of length, cable type, insulation of cable, tripping time of protection device</li>
<li>Global earth resistance without RCD tripping</li>
<li>Phase sequence indication</li>
<li>TFT display with touch-screen</li>
<li>Programmable timer on tests</li>
<li>Programmable thresholds on measurement</li>
<li>Internal memory</li>
<li>USB interface for PC connection</li>
<li>USB interface for keyboard, printer and barcode reader connection</li>
</ul>
<h3>Test to Guidelines:</h3>
<div class="col-sx-12 col-md-12 col-lg-12 nopadding_right nopadding_left">
<ul>
<li><i class="fa fa-check"></i> CEI 64-8</li>
<li><i class="fa fa-check"></i> CEI 64-8/7</li>
<li><i class="fa fa-check"></i> CE MARK</li>
<li><i class="fa fa-check"></i> EMC 2014/30/EU</li>
<li><i class="fa fa-check"></i> EMC: IEC/EN61326</li>
<li><i class="fa fa-check"></i> EN50106</li>
<li><i class="fa fa-check"></i> IEC/EN60204-1</li>
<li><i class="fa fa-check"></i> IEC/EN60598-1</li>
<li><i class="fa fa-check"></i> IEC/EN61010-1</li>
<li><i class="fa fa-check"></i> IEC/EN61187</li>
<li><i class="fa fa-check"></i> IEC/EN61335-1</li>
<li><i class="fa fa-check"></i> IEC/EN61439-1</li>
<li><i class="fa fa-check"></i> IEC/EN61439-2</li>
<li><i class="fa fa-check"></i> IEC/EN61557-1</li>
<li><i class="fa fa-check"></i> IEC/EN61557-13</li>
<li><i class="fa fa-check"></i> IEC/EN61557-14</li>
<li><i class="fa fa-check"></i> IEC/EN61557-2</li>
<li><i class="fa fa-check"></i> IEC/EN61557-3</li>
<li><i class="fa fa-check"></i> IEC/EN61557-4</li>
<li><i class="fa fa-check"></i> IEC/EN61557-6</li>
<li><i class="fa fa-check"></i> IEC/EN61557-7</li>
<li><i class="fa fa-check"></i> LVD 2014/35/EU</li>
<li><i class="fa fa-check"></i> UNE20460</li>
</ul>
</div>
<h3>Standard Accessories:</h3>
<ul>
<li>Australian Power cord</li>
<li>Test cable red, 3 metre, 2 pcs</li>
<li>Test cable blue, 3 metre</li>
<li>Test cable green, 3 metre</li>
<li>C2033X : Cable 3 wires with Shuko plug</li>
<li>Cable with 5kV safety, 2 pcs</li>
<li>Test lead CAT III, 3 pcs</li>
<li>Test lead CAT II, 3 pcs</li>
<li>Alligator clip, 3pcs</li>
<li>TOPVIEW2007 : Windows software + USB cable C2007</li>
<li>Carry bag for accessories</li>
<li>ISO9000 calibration certificate</li>
</ul>
<h3>Optional Accessories:</h3>
<ul>
<li>IMP57 : Accessory for high resolution Loop/Line Impedance</li>
<li>HT96U : Rigid clamp 1-100-1000A AC, diameter 54mm</li>
</ul>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST3-Accesories-banner.jpg"><img loading="lazy" decoding="async" class="aligncenter wp-image-16404 size-large" src="https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST3-Accesories-banner-1024x283.jpg" alt="" width="1020" height="282" srcset="https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST3-Accesories-banner-1024x283.jpg 1024w, https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST3-Accesories-banner-300x83.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST3-Accesories-banner-600x166.jpg 600w, https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST3-Accesories-banner-768x213.jpg 768w, https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST3-Accesories-banner.jpg 1250w" sizes="auto, (max-width: 1020px) 100vw, 1020px" /></a></p>
<p>The post <a href="https://rapid-tech.com.au/ht-instruments-fulltest3-professional-multifunction-safety-tester/">HT Instruments FULLTEST3 Professional Multifunction Safety Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HT Instruments HT9023 TRMS AC/DC Clamp-On Power Quality Analyzer</title>
		<link>https://rapid-tech.com.au/ht-instruments-ht9023-trms-ac-dc-clamp-on-power-quality-analyzer/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 30 Jun 2020 22:08:38 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=15802</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-5689" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/HTI-Auth.jpg" alt="" width="220" height="160" /></p>
<p><a target="_blank" href="https://mymeter.com.au/product/ht-instruments-ht9023-trms-ac-dc-clamp-on-power-quality-analyzer" rel="noopener"><img class="alignnone size-full wp-image-17843" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/BUY-NOW-form-My-Meter-e1620004827208.png" alt="Buy now form My Meter" width="220" height="55" /></a></p>
<p>The HT Instruments HT9023 has been designed to measure AC, DC AC+DC current up to 1000A in TRMS and is CAT IV 600V and CAT III 1000V rated in compliance with safety standard IEC/EN61010-1.</p>
<p>The HT9023 also measures DC voltage up to 1500V, AC, AC+DC voltage up to 1000V, Active, Reactive and Apparent Power, Power Factor, Energy, voltage/current harmonic analysis up to the 25th with THD% calculation in balanced single-phase or three-phase systems.</p>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/07/HT9023-Datasheet.pdf" rel="noopener">HT9023 Datasheet</a></span></h3>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/07/HT9023-User-Manual.pdf" rel="noopener">HT9023 User Manual</a></span></h3>
<p>The post <a href="https://rapid-tech.com.au/ht-instruments-ht9023-trms-ac-dc-clamp-on-power-quality-analyzer/">HT Instruments HT9023 TRMS AC/DC Clamp-On Power Quality Analyzer</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The HT Instruments HT9023 is able to measure AC, DC AC+DC current up to 1000A in TRMS and is CAT IV 600V and CAT III 1000V rated in compliance with safety standard IEC/EN61010-1.</p>
<p>The HT9023 can measures DC voltage up to 1500V, AC, AC+DC voltage up to 1000V, Active, Reactive and Apparent Power, Power Factor, Energy, voltage/current harmonic analysis up to the 25th with THD% calculation in balanced single-phase or three-phase systems.</p>
<p>With the HT Instruments HT9023 TRMS AC/DC Clamp-On Power Quality Analyzer it is also possible to carry out the phase sequence test with 1-terminal. The instrument also detects the events linked to motor starting currents (Dynamic INRUSH) and allows recording each measured electric parameter over time, with the possibility of transferring data via WiFi to Android/iOS devices through the HTAnalysis App or onto PC through the TOPVIEW software.</p>
<p>The HT9023 clamp is provided with a wide graphic dot-matrix screen (128x128pxl) with backlight, in order to allow reading data even in poorly lit environments, and it is provided with an auto power off function to preserve its internal battery.</p>
<div class="list-check">
<p>&nbsp;</p>
</div>
<p>The post <a href="https://rapid-tech.com.au/ht-instruments-ht9023-trms-ac-dc-clamp-on-power-quality-analyzer/">HT Instruments HT9023 TRMS AC/DC Clamp-On Power Quality Analyzer</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HT Instruments HT9025 AC / DC current clamp with DATA LOGGER function</title>
		<link>https://rapid-tech.com.au/ht-instruments-ht9025-ac-dc-current-clamp-with-data-logger-function/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Wed, 29 Apr 2020 04:22:58 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=15026</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/10/HTI-Auth.jpg"><img class="alignnone size-full wp-image-5689" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/HTI-Auth.jpg" alt="" width="220" height="160" /></a></p>
<p><a target="_blank" href="https://mymeter.com.au/product/ht-instruments-ht9025-ac-dc-current-clamp-with-data-logger-function/" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<p>THE HT Instruments HT9025 AC / DC current clamp with DATA LOGGER function is designed to measure AC/DC current up to 1000A, DC voltage up to 1500V &#38; AC voltage up to 1000V in TRMS reaching CAT IV 600V and CAT III 1000V in compliance with safety standard IEC/ EN61010-1.</p>
<p>It is ideal instrument for the<strong> industrial electrician</strong> and for use on<strong> large solar (photovoltaic) farms</strong>.</p>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a> <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/04/HT9025-Datasheet.pdf" rel="noopener">HT9025 Datasheet</a></h3>
<p>The post <a href="https://rapid-tech.com.au/ht-instruments-ht9025-ac-dc-current-clamp-with-data-logger-function/">HT Instruments HT9025 AC / DC current clamp with DATA LOGGER function</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>THE HT Instruments HT9025 AC / DC current clamp with DATA LOGGER function has been designed to measure AC/DC current up to 1000A, DC voltage up to 1500V and AC voltage up to 1000V in TRMS reaching CAT IV 600V and CAT III 1000V in compliance with safety standard IEC/ EN61010-1.</p>
<p>It is ideal instrument for the industrial electrician and for use on large solar (photovoltaic) farms with its 1500V DC function.</p>
<p>The clamp is provided with a display with 6000 measuring spots with backlight and bargraph to allow for a simple reading even in poorly lit environments. HT9025 also measures Resistance, Frequency, Capacity and Temperature with K-type probe.</p>
<p>The Bluetooth connection allows for the transfer of the saved snapshots by means of the dedicated App HTMercury.</p>
<h3 class="titlethin funz">HT Instruments HT9025 Functions</h3>
<div class="list-check">
<table border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>TRMS Measurement</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Current measuring range</td>
<td class="description">1000A</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>AC/DC current</td>
<td class="description">AC+DC</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>AC/DC voltage</td>
<td class="description">1000VAC / 1500VDC</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Leakage current with optional clamp meter</td>
<td class="description">External pliers</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Frequency</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Resistance and continuity test with buzzer</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Capacity</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Diode test</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Duty Cycle (%)</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Temperature with K-type probe</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>AC/DC current</td>
<td class="description">External clamp transducer</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Inrush current measurement (INRUSH)</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Measurement category</td>
<td class="description">CAT IV 600V CAT III 1000V</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Maximum diameter for clamp</td>
<td class="description">40mm</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Measuring counts</td>
<td class="description">6000</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Backlight</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Bargraph</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Autorange</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Auto power off</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Detection of AC voltage without contact</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Data HOLD function</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>MIN/MAX function</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Relative measurement</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Colour LCD display</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Datalogger and Graph</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Memory for data saving</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>PC / Smartphone or Tablet interface</td>
<td class="description">Bluetooth</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Power supply</td>
<td class="description">LI-ION battery</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Size (LxWx H) (mm)</td>
<td class="description">280 x 100 x 50</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Weight in grams (batteries included)</td>
<td class="description">505</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://rapid-tech.com.au/ht-instruments-ht9025-ac-dc-current-clamp-with-data-logger-function/">HT Instruments HT9025 AC / DC current clamp with DATA LOGGER function</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HT Instruments NEPTUNE Multimeter/Insulation Tester</title>
		<link>https://rapid-tech.com.au/ht-instruments-neptune-multimeter-insulation-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Wed, 19 Jun 2019 03:54:54 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=11983</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-5688" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/HTI-Auth-Med.jpg" alt="" width="165" height="120" /></p>
<p><a target="_blank" href="https://mymeter.com.au/product/ht-instruments-neptune-multimeter-insulation-tester/" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<h4>HT Instruments NEPTUNE Features:</h4>
<ul>
<li><span style="font-size: 90%;">Autorange function &#38; automatic detection of AC, DC for all measurements.</span></li>
<li><span style="font-size: 90%;">Insulation test voltages of 50,100,250,500,1000VDC</span></li>
<li><span style="font-size: 90%;">DC, AC TRMS, AC+DC TRMS voltage up to 1000V.</span></li>
<li><span style="font-size: 90%;">Low-impedance LoZ input to eliminate “stray voltages” from the measurement</span></li>
<li><span style="font-size: 90%;">DC, AC TRMS, AC+DC TRMS current by means of an optional external current clamp</span></li>
<li><span style="font-size: 90%;">Measurement of voltage or current frequency.</span></li>
<li><span style="font-size: 90%;">Resistance and continuity with buzzer.</span></li>
<li><span style="font-size: 90%;">MAX/MIN/PEAK/HOLD functions.</span></li>
<li><span style="font-size: 90%;"> CAT IV 600V, CAT III 1000V Safety Rating</span></li>
<li><span style="font-size: 90%;">ISO 9000 Calibration Certificate included</span></li>
<li><span style="font-size: 90%;">Similar to the Fluke 1587 &#38; Fluke 1577</span></li>
</ul>
<p><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" />    <a href="https://rapid-tech.com.au/wp-content/uploads/2019/06/NEPTUNE-Datasheet.pdf">NEPTUNE Datasheet</a></p>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/ht-instruments-neptune-multimeter-insulation-tester/">HT Instruments NEPTUNE Multimeter/Insulation Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The HT Instruments NEPTUNE Multimeter/Insulation Tester is a mix of technology that includes an instrument for electrical safety testing (insulation up to 1000V and continuity with 200mA), an Harmonics analyzer and a True  RMS multimeter.</p>
<h4>HT Instruments NEPTUNE Key Features:</h4>
<ul>
<li>it can quickly measure insulation up to 1000V, just like top-of-the-range testers.</li>
<li>50,100,250,500,1000VDC Insulation test voltages.</li>
<li>it measures continuity of protective conductors with 200mA to solve the most common problems related to masses.</li>
<li>measure Inrush currents, Harmonics and THD%, just like top-of-the-range power quality analyzers.</li>
<li>with a wide range of external clamp transducers it can measure AC TRMS, DC, AC+DC current and Inrush current, starting from 1mA up to 3000A.</li>
<li>compare each measurement with the limits prescribed by the Guidelines and I provide a clear result OK or NOT OK</li>
<li>it&#8217;s a multimeter with functions only available if using top-of-the-range instruments.</li>
<li>CAT IV 600V, CAT III 1000V Safety Rating</li>
<li>Similar to the Fluke 1587 &amp; Fluke 1577</li>
<li>ISO 9000 CALIBRATION CERTIFICATE INCLUDED</li>
</ul>
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellcategory" colspan="2">
<h4><strong>HT Instruments NEPTUNE Technical Specifications</strong></h4>
</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>DC voltage</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.0V ÷ 999.9V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.1V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(0.5%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>AC TRMS, DC, AC+DC TRMS, LoZ voltage</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.5V ÷ 999.9V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.1V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">32Hz ÷ 1kHz</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(0.5%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>AC TRMS current with flexible clamp F3000U</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1A ÷ 3000A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.01A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(0.5%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>AC TRMS, DC, AC+DC TRMS current with standard clamp</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1mV ÷ 1000mV</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1mV</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(0.5%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Inrush current (DIRC) &#8211; Flexible clamp F3000U</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1A ÷ 3000A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.01A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">42.5Hz ÷ 69Hz</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(2.0%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Response time of peak</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1ms</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Max RMS response time</span></td>
<td class="speccelldata"><span style="font-size: 90%;">16.6ms, 20ms, 50ms, 100ms, 150ms, 175ms, 200ms</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Inrush current (DIRC) &#8211; Standard clamp</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1mV ÷ 1000mV</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1mV</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">42.5Hz ÷ 69Hz</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(2.0%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Response time of peak</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1ms</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Max RMS response time</span></td>
<td class="speccelldata"><span style="font-size: 90%;">16.6ms, 20ms, 50ms, 100ms, 150ms, 175ms, 200ms</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Resistance and Continuity test</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.0Ω ÷ 1999Ω</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.1Ω</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(1.0%reading + 5digits)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Buzzer test</span></td>
<td class="speccelldata"><span style="font-size: 90%;">R&lt;30Ω</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Voltage / Current harmonics</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Harmonic order</span></td>
<td class="speccelldata"><span style="font-size: 90%;">DC, 1st ÷ 25th + THD%</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">42.5Hz ÷ 69Hz</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.1V / 0.1A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(5.0%rdg + 10digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Phase sequence with 1 terminal</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">100V ÷ 999.9V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">42.5Hz ÷ 69Hz</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Insulation resistance</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Test voltages</span></td>
<td class="speccelldata"><span style="font-size: 90%;">50,100,250,500,1000VDC</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range (@ 500V)</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.01MΩ ÷ 999MΩ</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.01MΩ ÷ 1MΩ</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic accuracy (@ 500V)</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(2.0%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Timer for measurements</span></td>
<td class="speccelldata"><span style="font-size: 90%;">15s, 30s, 1min, 5min, 10min</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Continuity of protective conductors</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Test current</span></td>
<td class="speccelldata"><span style="font-size: 90%;">&gt;200mA DC (@ R&lt;5Ω)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.00Ω ÷ 199.9Ω</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Open-circuit voltage</span></td>
<td class="speccelldata"><span style="font-size: 90%;">4 &lt; Vo &lt; 12V DC</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(2.0%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>General characteristics</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Instrument safety</span></td>
<td class="speccelldata"><span style="font-size: 90%;">IEC/EN61010-1, IEC/EN61010-2-030, IEC/EN61010-2-033</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">EMC</span></td>
<td class="speccelldata"><span style="font-size: 90%;">IEC/EN 61326-1</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Test MΩ</span></td>
<td class="speccelldata"><span style="font-size: 90%;">CEI 64-8, IEC/EN61557-2</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Test LoΩ</span></td>
<td class="speccelldata"><span style="font-size: 90%;">CEI 64-8, IEC/EN61557-4</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Phase sequence</span></td>
<td class="speccelldata"><span style="font-size: 90%;">IEC/EN 61557-7</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Insulation</span></td>
<td class="speccelldata"><span style="font-size: 90%;">double insulation</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Pollution level</span></td>
<td class="speccelldata"><span style="font-size: 90%;">2</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measurement category</span></td>
<td class="speccelldata"><span style="font-size: 90%;">CAT IV 600V, CAT III 1000V to earth and between inputs</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;">Mechanical characteristics</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Size (L x W x H)</span></td>
<td class="speccelldata"><span style="font-size: 90%;">175 x 85 x 55mm</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Weight (batteries included)</span></td>
<td class="speccelldata"><span style="font-size: 90%;">420g</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Mechanical protection</span></td>
<td class="speccelldata"><span style="font-size: 90%;">IP40</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Power supply</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Battery type</span></td>
<td class="speccelldata"><span style="font-size: 90%;">4&#215;1.5V batteries type AAA IEC LR03</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Auto power off</span></td>
<td class="speccelldata"><span style="font-size: 90%;">after 15 minutes’ idling</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;">Display</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Type of display</span></td>
<td class="speccelldata"><span style="font-size: 90%;">4 dgt LCD, max 9999 dots, decimal sign, point, backlight and bargraph, indication of polarity</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Updating frequency</span></td>
<td class="speccelldata"><span style="font-size: 90%;">2 times/s</span></td>
</tr>
</tbody>
</table>
<h3>HT Instruments NEPTUNE  Included Accessories:</h3>
<p>• 4324-2 Pair of Red/Black banana connectors with 2/4mm tip<br />
• YAAMK0001HT0 Pair of Red/Black alligator clips<br />
• YABAT0001HT0 Alkaline battery type AAA IEC LR03 1.5V, 4 pieces<br />
• YABRS0002HT0 Carrying bag<br />
• YAMUM0068HT0 User manual on CD-ROM<br />
• YAMUM0067HT0 Quick user guide<br />
• Calibration certificate ISO9000</p>
<h3>Optional Accessories:</h3>
<p>• F3000U Flexible clamp with full scale 30/300/3000A AC and banana connectors<br />
• HT96U* Standard clamp with full scale 1/100/1000A AC and Hypertac connector<br />
• HT97U* Standard clamp with full scale 10/100/1000A AC and Hypertac connector<br />
• HT98U* Standard clamp with full scale 1000A DC and Hypertac connector<br />
• HT4006 Standard clamp with full scale 40/400A AC/DC and banana connectors<br />
• NOCANBA Adapter for clamp connection with Hypertac connector<br />
• 5004-IECR Red alligator clip<br />
• 5004-IECN Black alligator clip<br />
• C2065 3-wire cable Red, Black and Green with Schuko plug</p>
<p>The post <a href="https://rapid-tech.com.au/ht-instruments-neptune-multimeter-insulation-tester/">HT Instruments NEPTUNE Multimeter/Insulation Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HT INSTRUMENTS HT309 Digital LED Light Lux Meter</title>
		<link>https://rapid-tech.com.au/ht-instruments-ht309-digital-led-light-lux-meter/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Mon, 04 Mar 2019 03:28:22 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=10107</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-5689" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/HTI-Auth.jpg" alt="" width="220" height="160" />                    <a target="_blank" href="https://mymeter.com.au/product/ht-instruments-ht309-digital-led-light-lux-meter/" rel="noopener noreferrer"><img class="alignnone wp-image-5427 size-thumbnail" src="https://rapid-tech.com.au/wp-content/uploads/2017/08/Buy-Now-small-150x65.jpg" alt="" width="150" height="65" /></a></p>
<p>The HT Instruments HT309 is digital light meters used to <strong>measure illuminance</strong> up to 400k Lux through a silicon photodiode sensor.</p>
<p>The HT309 also allows measuring illuminance of LED sources with various colours by setting the relevant correction factors, further to measuring luminous intensity (expressed in Candles).</p>
<h4><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" />    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2019/03/HT-Instruments-HT309-User-Manual.pdf" rel="noopener noreferrer">HT Instruments HT309 User Manual</a></span></h4>
<p>The post <a href="https://rapid-tech.com.au/ht-instruments-ht309-digital-led-light-lux-meter/">HT INSTRUMENTS HT309 Digital LED Light Lux Meter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The HT INSTRUMENTS HT309 Digital LED Light Lux Meter is a precision luxmeter used for measuring illuminance of both white light sources and LED sources of various colours, expressed in Lux (Lx) or Foot-candles (Fc). The instrument complies with CIE (International Commission on Illumination) standards on spectrum response and corrects according to the cosine of the angle of incidence of light. The silicon photodiode sensor used in the HT Instruments HT309 guarantees measurement stability.</p>
<h4>HT INSTRUMENTS HT309 Digital LED Light Lux Meter Features:</h4>
<p>• Illuminance measurement up to 400kLux / 40kFc<br />
• Luminous intensity measurement (expressed in Candles)<br />
• Selection of the measuring unit: Lx/Fc/CD<br />
• Light source: white light source and LED sources in their visible spectrum<br />
• High-precision and rapid measurements<br />
• Data HOLD function<br />
• MAX/MIN/AVG functions<br />
• Zeroing of the displayed value<br />
• Internal memory for saving measurement results<br />
• Auto Power OFF<br />
• Backlight<br />
• Autorange</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>The post <a href="https://rapid-tech.com.au/ht-instruments-ht309-digital-led-light-lux-meter/">HT INSTRUMENTS HT309 Digital LED Light Lux Meter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HT Instruments Mercury Infrared Digital Multimeter</title>
		<link>https://rapid-tech.com.au/ht-instruments-mercury-infrared-digital-multimeter/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Mon, 30 Jul 2018 02:04:12 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=8392</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/10/HTI-Auth.jpg"><img class="alignnone size-full wp-image-5689" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/HTI-Auth.jpg" alt="" width="220" height="160" /></a></p>
<p><span style="text-align: left; color: #2f2f2f; text-transform: none; text-indent: 0px; letter-spacing: normal; font-family: 'Roboto',sans-serif; font-size: 100%; font-style: normal; font-variant: normal; font-weight: 300; text-decoration: none; word-spacing: 0px; display: inline !important; white-space: normal; orphans: 2; float: none; text-shadow: none; -webkit-text-stroke-width: 0px; background-color: transparent;">The HT Instruments Mercury is a Professional CAT IV 600V – CAT III 1000V Digital Multimeter with built-in infrared camera &#38; comes standard with a  F3000U AC flexible clamp with 30/300/3000A full scale</span></p>
<p><span style="font-size: 100%;"><span style="color: #353535;">The HT Instruments Mercury Infrared Digital Multimeter i</span><span style="text-align: left; color: #353535; text-transform: none; line-height: 26.66px; text-indent: 0px; letter-spacing: normal; font-family: Roboto,'sans-serif'; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; display: inline !important; white-space: normal; orphans: 2; float: none; text-shadow: none; -webkit-text-stroke-width: 0px; background-color: transparent;">s a </span>TRMS digital multimeter capable<span style="text-align: left; color: #353535; text-transform: none; line-height: 26.66px; text-indent: 0px; letter-spacing: normal; font-family: Roboto,'sans-serif'; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; display: inline !important; white-space: normal; orphans: 2; float: none; text-shadow: none; -webkit-text-stroke-width: 0px; background-color: transparent;"> of measuring</span> AC/DC voltage<span style="text-align: left; color: #353535; text-transform: none; line-height: 26.66px; text-indent: 0px; letter-spacing: normal; font-family: Roboto,'sans-serif'; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; display: inline !important; white-space: normal; orphans: 2; float: none; text-shadow: none; -webkit-text-stroke-width: 0px; background-color: transparent;"> up to </span>1000V<span style="text-align: left; color: #353535; text-transform: none; line-height: 26.66px; text-indent: 0px; letter-spacing: normal; font-family: Roboto,'sans-serif'; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; display: inline !important; white-space: normal; orphans: 2; float: none; text-shadow: none; -webkit-text-stroke-width: 0px; background-color: transparent;">, </span>AC/DC<span style="text-align: left; color: #353535; text-transform: none; line-height: 26.66px; text-indent: 0px; letter-spacing: normal; font-family: Roboto,'sans-serif'; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; display: inline !important; white-space: normal; orphans: 2; float: none; text-shadow: none; -webkit-text-stroke-width: 0px; background-color: transparent;"> </span>current<span style="text-align: left; color: #353535; text-transform: none; line-height: 26.66px; text-indent: 0px; letter-spacing: normal; font-family: Roboto,'sans-serif'; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; display: inline !important; white-space: normal; orphans: 2; float: none; text-shadow: none; -webkit-text-stroke-width: 0px; background-color: transparent;"> up to </span>10A <span style="text-align: left; color: #353535; text-transform: none; line-height: 26.66px; text-indent: 0px; letter-spacing: normal; font-family: Roboto,'sans-serif'; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; display: inline !important; white-space: normal; orphans: 2; float: none; text-shadow: none; -webkit-text-stroke-width: 0px; background-color: transparent;">as well as </span>resistance, continuity test, diode test, frequency, capacitance and temperature with K-type probe<span style="text-align: left; color: #353535; text-transform: none; line-height: 26.66px; text-indent: 0px; letter-spacing: normal; font-family: Roboto,'sans-serif'; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; display: inline !important; white-space: normal; orphans: 2; float: none; text-shadow: none; -webkit-text-stroke-width: 0px; background-color: transparent;">.</span></span></p>
<p><span style="text-align: left; color: #353535; text-transform: none; line-height: 26.66px; text-indent: 0px; letter-spacing: normal; font-family: Roboto,'sans-serif'; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; display: inline !important; white-space: normal; orphans: 2; float: none; text-shadow: none; -webkit-text-stroke-width: 0px; background-color: transparent;">Other major functions include </span><span style="font-size: 100%; color: #333333;">AC+DC </span><span style="text-align: left; color: #353535; text-transform: none; line-height: 26.66px; text-indent: 0px; letter-spacing: normal; font-family: Roboto,'sans-serif'; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; display: inline !important; white-space: normal; orphans: 2; float: none; text-shadow: none; -webkit-text-stroke-width: 0px; background-color: transparent;">mode taking into account </span><span style="font-size: 100%; color: #333333;">DC </span><span style="text-align: left; color: #353535; text-transform: none; line-height: 26.66px; text-indent: 0px; letter-spacing: normal; font-family: Roboto,'sans-serif'; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; display: inline !important; white-space: normal; orphans: 2; float: none; text-shadow: none; -webkit-text-stroke-width: 0px; background-color: transparent;">components overlapping </span><span style="font-size: 100%; color: #333333;">AC</span><span style="text-align: left; color: #353535; text-transform: none; line-height: 26.66px; text-indent: 0px; letter-spacing: normal; font-family: Roboto,'sans-serif'; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; display: inline !important; white-space: normal; orphans: 2; float: none; text-shadow: none; -webkit-text-stroke-width: 0px; background-color: transparent;"> signals and </span><span style="font-size: 100%; color: #333333;">current measuremen</span><span style="text-align: left; color: #353535; text-transform: none; line-height: 26.66px; text-indent: 0px; letter-spacing: normal; font-family: Roboto,'sans-serif'; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; display: inline !important; white-space: normal; orphans: 2; float: none; text-shadow: none; -webkit-text-stroke-width: 0px; background-color: transparent;">t with standard and flexible transducer clamps<strong> (the HT F3000U Flexible Current Clamp is included with the HT Mercury). </strong></span></p>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Instruments-Mercury-Datasheet.pdf" rel="noopener">HT Instruments Mercury Datasheet</a></span></h4>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>   <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Instruments-Mercury-Brochure-1.pdf" rel="noopener">HT Instruments Mercury Brochure</a></span></h4>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>   <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Instruments-Mercury-User-Manual.pdf" rel="noopener">HT Instruments Mercury User Manual</a></span></h4>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/ht-instruments-mercury-infrared-digital-multimeter/">HT Instruments Mercury Infrared Digital Multimeter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3><span style="font-size: 110%;">HT Instruments Mercury Infrared Digital Multimeter</span></h3>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Mercury-Multimeter-c.jpg"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-8406" src="https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Mercury-Multimeter-c.jpg" alt="" width="1053" height="379" srcset="https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Mercury-Multimeter-c.jpg 1053w, https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Mercury-Multimeter-c-300x108.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Mercury-Multimeter-c-600x216.jpg 600w, https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Mercury-Multimeter-c-768x276.jpg 768w, https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Mercury-Multimeter-c-1024x369.jpg 1024w" sizes="auto, (max-width: 1053px) 100vw, 1053px" /></a></p>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Mercury-Multimeter-a.jpg"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-8407" src="https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Mercury-Multimeter-a.jpg" alt="" width="1053" height="380" srcset="https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Mercury-Multimeter-a.jpg 1053w, https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Mercury-Multimeter-a-300x108.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Mercury-Multimeter-a-600x217.jpg 600w, https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Mercury-Multimeter-a-768x277.jpg 768w, https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Mercury-Multimeter-a-1024x370.jpg 1024w" sizes="auto, (max-width: 1053px) 100vw, 1053px" /></a></p>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Mercury-Multimeter-b.jpg"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-8409" src="https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Mercury-Multimeter-b.jpg" alt="" width="1054" height="374" srcset="https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Mercury-Multimeter-b.jpg 1054w, https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Mercury-Multimeter-b-300x106.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Mercury-Multimeter-b-600x213.jpg 600w, https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Mercury-Multimeter-b-768x273.jpg 768w, https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Mercury-Multimeter-b-1024x363.jpg 1024w" sizes="auto, (max-width: 1054px) 100vw, 1054px" /></a></p>
<h3><span style="font-size: 110%;">HT Instruments MERCURY Multimeter Function:</span></h3>
<ul>
<li>DC/ AC / AC+DC TRMS voltage</li>
<li>DC / AC / AC+DC TRMS current</li>
<li>DC / AC / AC+DC TRMS current with clamp transducer</li>
<li>Resistance and Continuity test</li>
<li>Diode test</li>
<li>Capacitance</li>
<li>Frequency</li>
<li>Duty Cycle</li>
<li>Temperature with K-type probe</li>
<li>Data Logger function and display of graphs of measured data</li>
<li>Storage of BMP images on external micro SD card</li>
<li>CAT IV 600V – CAT III 1000V Safety Rating</li>
</ul>
<h3><span style="font-size: 110%;">HT Instruments MERCURY Thermal Imaging Camera Function:</span></h3>
<ul>
<li>Infrared temperature measurement ranging from -20°C to 260°C</li>
<li>3 measuring cursors (central steady + hot spot + cold spot)</li>
<li>Emissivity of materials which can be selected between 0.01 and 1.00</li>
<li>Image frequency: 50Hz</li>
<li>5 selectable color palettes</li>
<li>Automatic detection of hot/cold spots of the image</li>
<li>Storage of BMP images on external micro SD card</li>
<li>IR sensor resolution: 80x80pxl</li>
<li>Bluetooth connection to mobile devices through the APP HTMercury</li>
<li>Built-in laser pointer and illuminator</li>
</ul>
<p>Each of the above functions can be selected by means of the appropriate switch. The MERCURY is also equipped with function keys, analogue bargraph and LCD TFT high-contrast color display. The Mercury is also equipped with an Auto Power OFF function which automatically switches off the instrument after a certain (programmable) idling time.</p>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-App-Mercury.jpg"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-8413" src="https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-App-Mercury.jpg" alt="" width="873" height="295" srcset="https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-App-Mercury.jpg 873w, https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-App-Mercury-300x101.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-App-Mercury-600x203.jpg 600w, https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-App-Mercury-768x260.jpg 768w" sizes="auto, (max-width: 873px) 100vw, 873px" /></a></p>
<h4>Included Accessories:</h4>
<ul>
<li>Pair of leads (red &amp; black) with 2/4mm tip (Code 4413-2)</li>
<li>Adapter &amp; K-type thermocouple wire probe</li>
<li>Flexible clamp transducer AC 30/300/3000A (Code F3000U)</li>
<li>Li-ION rechargeable battery, 2 pieces (Code BATMCY)</li>
<li>Multiplug Universal power supply + recharging base (Code A0MCY)</li>
<li>Alkaline battery type AAA LR03, 2 pieces</li>
<li>Micro SD card, 8GB</li>
<li>Carrying bag (Code B0MCY)</li>
<li>ISO9000 calibration certificate</li>
<li>User manuals</li>
</ul>
<h3><span style="font-size: 110%;">Why True RMS?</span></h3>
<p>Measuring instruments for AC are divided into two types: </p>
<ul>
<li>AVERAGE-VALUE meters: instruments measuring the value of the sole wave at fundamental frequency (50 or 60 Hz). </li>
<li>TRMS (True Root Mean Square) VALUE meters</li>
</ul>
<p>True RMS instruments measuring the TRMS value of the quantity being tested. With a perfectly sinusoidal wave, the two families of instruments provide identical results. With distorted waves, instead, the readings shall differ.</p>
<p>Average-value meters provide the RMS value of the sole fundamental wave; TRMS meters, instead, provide the RMS value of the whole wave, including harmonics (within the instruments bandwidth).</p>
<p>Therefore, by measuring the same quantity with instruments from both types, the values obtained are identical only if the wave is perfectly sinusoidal. In case it is distorted, TRMS meters shall provide higher values than the values read by average-value meters.</p>
<p>The post <a href="https://rapid-tech.com.au/ht-instruments-mercury-infrared-digital-multimeter/">HT Instruments Mercury Infrared Digital Multimeter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HT Instruments FLASHMETER TRMS Digital Multimeter</title>
		<link>https://rapid-tech.com.au/ht-instruments-flashmeter-trms-digital-multimeter/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Wed, 17 Jan 2018 11:01:56 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=6156</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/10/HTI-Auth.jpg"><img class="alignnone size-full wp-image-5689" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/HTI-Auth.jpg" alt="" width="220" height="160" /></a></p>
<p>&#160;</p>
<p><a target="_blank" href="https://mymeter.com.au/product/ht-instruments-flashmeter-rugged-digital-multimeter/" rel="noopener"><img class="alignnone size-full wp-image-17843" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/BUY-NOW-form-My-Meter-e1620004827208.png" alt="Buy now form My Meter" width="220" height="55" /></a></p>
<p class="strong">The HT Instruments Flashmeter is a True RMS Digital multimeter up to CAT-IV 600V and water resistant with automatic measurement sequence</p>
<p>The FLASHMETER is a compact DMM capable of carrying out TRMS voltage measurements up to 600V as well as resistance measurements automatically under autorange, just connecting input terminals. It was designed in compliance with safety standards IEC/EN61010-1 with double insulation protection under CAT IV 600V. FLASHMETER is provided with a white light torch, a probe to detect AC voltage without contact and is water resistant according to IP67.</p>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2017/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-5148" src="https://rapid-tech.com.au/wp-content/uploads/2017/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2018/01/HT-Instruments-Flashmeter-Datasheet.pdf" rel="noopener">HT Instruments Flashmeter Datasheet</a></h3>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2017/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-5148" src="https://rapid-tech.com.au/wp-content/uploads/2017/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2018/01/HT-Instruments-Flashmeter-User-Manual.pdf" rel="noopener">HT Instruments Flashmeter User Manual</a></h3>
<p>The post <a href="https://rapid-tech.com.au/ht-instruments-flashmeter-trms-digital-multimeter/">HT Instruments FLASHMETER TRMS Digital Multimeter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<h3></h3>
<div class="row"  id="row-1876363181">

	<div id="col-1569074627" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<p>The HT Instruments FLASHMETER is a compact DMM capable of carrying out TRMS voltage measurements up to 600V as well as resistance measurements automatically under autorange, just connecting input terminals.</p>
<p>It was designed in compliance with safety standards IEC/EN61010-1 with double insulation protection under CAT IV 600V. The HT Instruments FLASHMETER has an inbuilt white light torch, a non-contact probe to detect AC voltage and is water resistant according to IP67.</p>
		</div>
					</div>

	

	<div id="col-942342183" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<a href="https://rapid-tech.com.au/wp-content/uploads/2018/01/HT-Instruments-Flashmeter-sm.jpg"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-6157" src="https://rapid-tech.com.au/wp-content/uploads/2018/01/HT-Instruments-Flashmeter-sm.jpg" alt="" width="300" height="300" srcset="https://rapid-tech.com.au/wp-content/uploads/2018/01/HT-Instruments-Flashmeter-sm.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2018/01/HT-Instruments-Flashmeter-sm-100x100.jpg 100w, https://rapid-tech.com.au/wp-content/uploads/2018/01/HT-Instruments-Flashmeter-sm-150x150.jpg 150w" sizes="auto, (max-width: 300px) 100vw, 300px" /></a></p>
		</div>
					</div>

	
</div>
<h3 class="titlethin funz">HT Instuments FlashMeter Specifications:</h3>
<div class="list-check">
<table border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr class="list-item">
<td class="function">Protection category</td>
<td class="description">CAT IV 600V</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function">Protection rating</td>
<td class="description">IP67</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function">Auto Power OFF</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function">TRMS</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function">Automatic recognition of internal functions</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function">AC/DC voltage</td>
<td class="description">600V</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function">Resistance</td>
<td class="description">40.0Ω &#8211; 400.0kΩ</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function">Continuity with buzzer</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function">Integrated white light illuminator</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function">Measuring counts</td>
<td class="description">4000</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function">Power supply</td>
<td class="description">2 x 1.5V AAA LR03</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function">Backlight</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function">Weight</td>
<td class="description">220g</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function">Size (LxWxH) (mm)</td>
<td class="description">140x75x40mm</td>
</tr>
</tbody>
</table>
</div>
<h3>The Ht Instruments FlashMeter conforms to the following standards:</h3>
<div class="col-sx-12 col-md-12 col-lg-12 nopadding_right nopadding_left">
<ul>
<li> EMC 2004/108/CE Directive</li>
</ul>
</div>
<div class="col-sx-12 col-md-12 col-lg-12 nopadding_right nopadding_left">
<ul>
<li><i class="fa fa-check"></i> LVD 2006/95/CE Directive</li>
</ul>
</div>
<div class="col-sx-12 col-md-12 col-lg-12 nopadding_right nopadding_left">
<ul>
<li><i class="fa fa-check"></i> IEC/EN 61010-1</li>
</ul>
</div>
<div class="col-sx-12 col-md-12 col-lg-12 nopadding_right nopadding_left">
<ul>
<li><i class="fa fa-check"></i> EMC: IEC/EN61326</li>
</ul>
</div>
<p>The post <a href="https://rapid-tech.com.au/ht-instruments-flashmeter-trms-digital-multimeter/">HT Instruments FLASHMETER TRMS Digital Multimeter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HT Instruments HA000951 Line Splitter &#8211; Separator</title>
		<link>https://rapid-tech.com.au/ht-instruments-ha000951-line-splitter-separator/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Wed, 25 Oct 2017 05:39:41 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=5756</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2016/05/HTI-Auth-Large.jpg"><img class="alignnone size-full wp-image-5691" src="https://rapid-tech.com.au/wp-content/uploads/2016/05/HTI-Auth-Large.jpg" alt="" width="350" height="160" /></a></p>
<p><a target="_blank" href="https://mymeter.com.au/product/ht-instruments-ac-line-splitter-separator/" rel="noopener"><img class="alignnone size-full wp-image-17843" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/BUY-NOW-form-My-Meter-e1620004827208.png" alt="Buy now form My Meter" width="220" height="55" /></a></p>
<p>The HT Instruments HA000951 Line Splitter is a special accessory for clamp meters that allows you to conveniently measure current without destroying the insulation part of an equipment’s power cable.</p>
<p>It can also be used to safely measure the line voltage being supplied to the equipment with a digital multimeter via its safety shrouded banana sockets. It’s a “must have” tool for anyone involved in electrical testing.</p>
<p><strong>The LINESPLITTER</strong> was designed by <strong>HT</strong> to <strong>carry out splitting among active Phase, Neutral and PE</strong> conductors on single-phase installations powered by 2- or 3-pole cord cables.</p>
<p><em><strong>Can be connected to 10A and 15A outlets.</strong></em></p>
<p>You will be able to take <strong>immediate measurements </strong>of <strong>current by means of a clamp meter, which would be otherwise impossible without stripping the cable to get access to individual conductors, and line voltage with a DMM's probes in the voltage test points ,</strong></p>
<p>Supplied with Australian plug and socket.</p>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2017/05/pdf_sml-1.png"><img class="alignnone size-full wp-image-5149" src="https://rapid-tech.com.au/wp-content/uploads/2017/05/pdf_sml-1.png" alt="" width="40" height="40" /></a>    <span style="color: #0000ff;"><a href="https://rapid-tech.com.au/wp-content/uploads/2017/10/HT-Splitter-datasheet.pdf">HT Splitter datasheet</a></span></h3>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2017/05/pdf_sml-1.png"><img class="alignnone size-full wp-image-5149" src="https://rapid-tech.com.au/wp-content/uploads/2017/05/pdf_sml-1.png" alt="" width="40" height="40" /></a>    <span style="color: #0000ff;"><a href="https://rapid-tech.com.au/wp-content/uploads/2017/10/HT-Splitter-User-Manual.pdf">HT Splitter User Manual</a></span></h3>
<p>&#160;</p>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/ht-instruments-ha000951-line-splitter-separator/">HT Instruments HA000951 Line Splitter &#8211; Separator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>HT Instruments HA000951 Line Splitter &#8211; Separator</h3>
<p>The HT Line Splitter separates the Active (Line) from the neutral and ground wires on a standard 240VAC 10A &amp; 15A outlet allowing current measurements to be made with a current clamp. Without the Line Splitter, the current clamp measures the load current going in both directions, effectively cancelling the measurement.</p>
<p>The HT Line Splitter has a standard measurement section and a x10 multiplier section for use with higher ranged clamp meters.</p>
<p>The HT Instruments HA000951 Line Splitter can also be used to make voltage checks safely with standard multimeter probes.</p>
<p>Suitable for bot 10A and 15A outlets.</p>
<figure id="attachment_5759" aria-describedby="caption-attachment-5759" style="width: 600px" class="wp-caption aligncenter"><a href="https://rapid-tech.com.au/wp-content/uploads/2017/10/HT-linesplitter_eng.jpg"><img loading="lazy" decoding="async" class="wp-image-5759 size-full" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/HT-linesplitter_eng.jpg" alt="" width="600" height="338" srcset="https://rapid-tech.com.au/wp-content/uploads/2017/10/HT-linesplitter_eng.jpg 600w, https://rapid-tech.com.au/wp-content/uploads/2017/10/HT-linesplitter_eng-300x169.jpg 300w" sizes="auto, (max-width: 600px) 100vw, 600px" /></a><figcaption id="caption-attachment-5759" class="wp-caption-text">HT Instruments HA000951 Line Splitter &#8211; Separator</figcaption></figure>
<p style="text-align: center;"><iframe loading="lazy" src="https://www.youtube.com/embed/BvyJHv7nFtU" width="560" height="315" frameborder="0" allowfullscreen="allowfullscreen"></iframe></p>
<h4 class="titlethin funz">HT Instruments HA000951 Line Splitter Functions:</h4>
<p><strong>Conductor splitting without cable stripping!</strong></p>
<ul>
<li>Measure Mains voltages safely via shrouded banana sockets</li>
<li>Leakage current on earth conductor</li>
<li>Measurement of leakage current under RCD mode (Line-Neutral)</li>
<li>Line current</li>
<li>10X magnified Line current</li>
</ul>
<div class="list-check"></div>
<p>&nbsp;</p>
<p>The post <a href="https://rapid-tech.com.au/ht-instruments-ha000951-line-splitter-separator/">HT Instruments HA000951 Line Splitter &#8211; Separator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
