<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Data Acquisition System Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/product-tag/data-acquisition-system/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/product-tag/data-acquisition-system/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Mon, 15 Sep 2025 05:18:14 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.5</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>Data Acquisition System Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/product-tag/data-acquisition-system/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Data Acquisition System &#124; Keysight DAQ970A &#124; DAQ973A</title>
		<link>https://rapid-tech.com.au/data-acquisition-system-keysight-daq970a-daq973a/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Thu, 26 Aug 2021 03:28:48 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=19498</guid>

					<description><![CDATA[<p><img class="size-medium wp-image-19245 alignnone" src="https://rapid-tech.com.au/wp-content/uploads/2021/08/keysight-logo-300x70.png" alt="keysight logo" width="300" height="70" /><a href="https://rapid-tech.com.au/wp-content/uploads/2021/08/keysight-logo.jpg"></a></p>
<p class="p1"><span style="font-weight: 400;">This Keysight DAQ970A / DAQ973A next-generation data acquisition (DAQ) system has a three-slot mainframe and nine plug-in modules. The DAQ can be accessed from Keysight BenchVue DAQ software or from the front panel's easy-to-use graphical display with self-guiding, task-oriented menus.</span></p>
<p><img class="alignnone size-full wp-image-17809" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-Download-e1620015214396.png" alt="PDF Download icon" width="51" height="60" /><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2021/08/Keysight-DAQ970A_DAQ973A-Datasheet.pdf" rel="noopener">DAQ970A/DAQ973A - Datasheet</a>   <img class="alignnone size-full wp-image-17809" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-Download-e1620015214396.png" alt="PDF Download icon" width="51" height="60" /> <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2021/08/Keysight-DAQ970ADAQ973A-Fact-sheet.pdf" rel="noopener">DAQ970A/DAQ973A - Fact sheet</a></p>
<p>The post <a href="https://rapid-tech.com.au/data-acquisition-system-keysight-daq970a-daq973a/">Data Acquisition System | Keysight DAQ970A | DAQ973A</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3><span style="font-weight: 400;">Data Acquisition System Of The Future</span></h3>
<p>The DAQ970A / DAQ973A data acquisition systems feature high-quality switching and an advanced 6.5 digit DMM that provides accurate measurements.</p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">6.5 digit DMM with three slots integrated into a mainframe</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Nine plug-in modules for switch and control</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Measures and converts 12 different input signals, including temperature with thermocouples, </span><span style="font-weight: 400;">direct strain and bridge strain,</span> <span style="font-weight: 400;">thermistors and RTDs, AC/DC volts, 2- and 4-wire resistance, AC/DC current, capacitance, frequency and period</span></li>
<li aria-level="1"><span style="font-weight: 400;">Easy PC connectivity via USB, LAN, or GPIB interface</span></li>
<li aria-level="1"><span style="font-weight: 400;">Virtual front panel control via Web interface for point and click monitor and control</span></li>
</ul>
<p>&nbsp;</p>
<div class="row"  id="row-1187533156">

	<div id="col-1380875314" class="col medium-12 small-12 large-6"  >
				<div class="col-inner" style="background-color:rgb(244, 244, 244);" >
			
			
	<div class="img has-hover x md-x lg-x y md-y lg-y" id="image_819312838">
		<a class="image-lightbox lightbox-gallery" title="" href="https://rapid-tech.com.au/wp-content/uploads/2021/08/3-keysight-DAQ970A-data-acquisition-system-with-BenchVue-DAQ-for-simple-test-automation-and-control-1024x557.jpg">						<div class="img-inner dark" >
			<img fetchpriority="high" decoding="async" width="1020" height="555" src="https://rapid-tech.com.au/wp-content/uploads/2021/08/3-keysight-DAQ970A-data-acquisition-system-with-BenchVue-DAQ-for-simple-test-automation-and-control-1024x557.jpg" class="attachment-large size-large" alt="Keysight DAQ970A data acquisition system with BenchVue" srcset="https://rapid-tech.com.au/wp-content/uploads/2021/08/3-keysight-DAQ970A-data-acquisition-system-with-BenchVue-DAQ-for-simple-test-automation-and-control-1024x557.jpg 1024w, https://rapid-tech.com.au/wp-content/uploads/2021/08/3-keysight-DAQ970A-data-acquisition-system-with-BenchVue-DAQ-for-simple-test-automation-and-control-300x163.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2021/08/3-keysight-DAQ970A-data-acquisition-system-with-BenchVue-DAQ-for-simple-test-automation-and-control-768x418.jpg 768w, https://rapid-tech.com.au/wp-content/uploads/2021/08/3-keysight-DAQ970A-data-acquisition-system-with-BenchVue-DAQ-for-simple-test-automation-and-control-1536x836.jpg 1536w, https://rapid-tech.com.au/wp-content/uploads/2021/08/3-keysight-DAQ970A-data-acquisition-system-with-BenchVue-DAQ-for-simple-test-automation-and-control-600x326.jpg 600w, https://rapid-tech.com.au/wp-content/uploads/2021/08/3-keysight-DAQ970A-data-acquisition-system-with-BenchVue-DAQ-for-simple-test-automation-and-control.jpg 2000w" sizes="(max-width: 1020px) 100vw, 1020px" />						
					</div>
						</a>		
<style>
#image_819312838 {
  width: 100%;
}
</style>
	</div>
	
<h4><span style="font-weight: 400;">Key DAQ970A and DAQ973A Mainframe Capabilities</span></h4>
<hr />
<table style="height: 668px;" width="380">
<tbody>
<tr>
<td><strong>Features</strong></td>
<td><strong>Description</strong></td>
</tr>
<tr>
<td><strong>Types of measurements</strong></td>
<td><span style="font-weight: 400;">Temperature, voltage, current, resistance, frequency, diode and capacitance, </span>direct strain and bridge strain</td>
</tr>
<tr>
<td><strong>Digital Input/Output</strong></td>
<td><span style="font-weight: 400;">Up to 48-bits</span></td>
</tr>
<tr>
<td><strong>Analog output</strong></td>
<td><span style="font-weight: 400;">-10 V to +10 V, 20 mA</span></td>
</tr>
<tr>
<td><strong>Multiplexing</strong></td>
<td><span style="font-weight: 400;">Maximum 120 (1-wire), 60 (2-wire) channels</span></td>
</tr>
<tr>
<td><strong>Matrix switching</strong></td>
<td><span style="font-weight: 400;">Maximum 96 cross points</span></td>
</tr>
<tr>
<td><strong>General purpose</strong></td>
<td><span style="font-weight: 400;">Maximum 60 switches</span></td>
</tr>
<tr>
<td><strong>RF multiplexing</strong></td>
<td><span style="font-weight: 400;">Maximum 24 channels, 2 GHz</span></td>
</tr>
<tr>
<td><strong>Simultaneous sampling</strong></td>
<td><span style="font-weight: 400;">Maximum 12 channels, up to 800 kSa/s, 24-bit resolution</span></td>
</tr>
<tr>
<td><strong>Interface</strong></td>
<td><span style="font-weight: 400;">Graphic web, USB front/rear, LAN/LXI, GPIB (only for DAQ973A)</span></td>
</tr>
</tbody>
</table>
		</div>
				
<style>
#col-1380875314 > .col-inner {
  padding: 15px 15px 14px 15px;
}
</style>
	</div>

	

	<div id="col-1246362562" class="col medium-12 small-12 large-6"  >
				<div class="col-inner" style="background-color:rgb(254, 255, 246);" >
			
			
	<div class="img has-hover x md-x lg-x y md-y lg-y" id="image_995973455">
		<a class="image-lightbox lightbox-gallery" title="" href="https://rapid-tech.com.au/wp-content/uploads/2021/08/DAQ970A-and-DAQ973A-Plug-in-Modules.jpg">						<div class="img-inner dark" >
			<img decoding="async" width="1000" height="544" src="https://rapid-tech.com.au/wp-content/uploads/2021/08/DAQ970A-and-DAQ973A-Plug-in-Modules.jpg" class="attachment-large size-large" alt="" srcset="https://rapid-tech.com.au/wp-content/uploads/2021/08/DAQ970A-and-DAQ973A-Plug-in-Modules.jpg 1000w, https://rapid-tech.com.au/wp-content/uploads/2021/08/DAQ970A-and-DAQ973A-Plug-in-Modules-300x163.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2021/08/DAQ970A-and-DAQ973A-Plug-in-Modules-768x418.jpg 768w, https://rapid-tech.com.au/wp-content/uploads/2021/08/DAQ970A-and-DAQ973A-Plug-in-Modules-600x326.jpg 600w" sizes="(max-width: 1000px) 100vw, 1000px" />						
					</div>
						</a>		
<style>
#image_995973455 {
  width: 100%;
}
</style>
	</div>
	
<h4><span style="font-weight: 400;">DAQ970A and DAQ973A Plug-in Modules</span></h4>
<hr />
<table style="height: 772px;" width="285">
<tbody>
<tr>
<td><strong>Part</strong></td>
<td><strong>Description</strong></td>
</tr>
<tr>
<td><strong>DAQ970A</strong></td>
<td><span style="font-weight: 400;">DAQ mainframe with USB and LAN interfaces</span></td>
</tr>
<tr>
<td><strong>DAQ973A</strong></td>
<td><span style="font-weight: 400;">DAQ mainframe with USB, LAN and GPIB interfaces</span></td>
</tr>
<tr>
<td><strong>DAQM900A</strong></td>
<td><span style="font-weight: 400;">20-channel solid state multiplexer</span></td>
</tr>
<tr>
<td><strong>DAQM901A</strong></td>
<td><span style="font-weight: 400;">20-channel armature multiplexer</span></p>
<p><span style="font-weight: 400;">+ 2 current channels</span></td>
</tr>
<tr>
<td><strong>DAQM902A</strong></td>
<td><span style="font-weight: 400;">16-channel reed multiplexer</span></td>
</tr>
<tr>
<td><strong>DAQM903A</strong></td>
<td><span style="font-weight: 400;">20-channel actuator/GP switch</span></td>
</tr>
<tr>
<td><strong>DAQM904A</strong></td>
<td><span style="font-weight: 400;">4 x 8 matrix</span></td>
</tr>
<tr>
<td><strong>DAQM905A</strong></td>
<td><span style="font-weight: 400;">Dual 4-channel 50 Ω RF mux</span></td>
</tr>
<tr>
<td><strong>DAQM907A</strong></td>
<td><span style="font-weight: 400;">Multifunction module</span></td>
</tr>
<tr>
<td><strong>DAQM908A</strong></td>
<td><span style="font-weight: 400;">40-channel armature multiplexer</span></td>
</tr>
<tr>
<td><strong>DAQM909A</strong></td>
<td><span style="font-weight: 400;">4-channel 24-bit simultaneous sampling digitizer</span></td>
</tr>
</tbody>
</table>
		</div>
				
<style>
#col-1246362562 > .col-inner {
  padding: 15px 15px 15px 15px;
}
</style>
	</div>

	
</div>
<div class="row"  id="row-1902843101">

	<div id="col-1108551706" class="col medium-6 small-12 large-6"  >
				<div class="col-inner"  >
			
			
	<div class="img has-hover x md-x lg-x y md-y lg-y" id="image_588470336">
		<a class="image-lightbox lightbox-gallery" title="" href="https://rapid-tech.com.au/wp-content/uploads/2021/08/Keysight-DAQ970A-DAQ973A-c2.jpg">						<div class="img-inner dark" >
			<img loading="lazy" decoding="async" width="997" height="561" src="https://rapid-tech.com.au/wp-content/uploads/2021/08/Keysight-DAQ970A-DAQ973A-c2.jpg" class="attachment-large size-large" alt="" srcset="https://rapid-tech.com.au/wp-content/uploads/2021/08/Keysight-DAQ970A-DAQ973A-c2.jpg 997w, https://rapid-tech.com.au/wp-content/uploads/2021/08/Keysight-DAQ970A-DAQ973A-c2-300x169.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2021/08/Keysight-DAQ970A-DAQ973A-c2-768x432.jpg 768w, https://rapid-tech.com.au/wp-content/uploads/2021/08/Keysight-DAQ970A-DAQ973A-c2-600x338.jpg 600w" sizes="auto, (max-width: 997px) 100vw, 997px" />						
					</div>
						</a>		
<style>
#image_588470336 {
  width: 100%;
}
</style>
	</div>
	
		</div>
					</div>

	

	<div id="col-232162036" class="col medium-6 small-12 large-6"  >
				<div class="col-inner"  >
			
			
	<div class="img has-hover x md-x lg-x y md-y lg-y" id="image_459988337">
		<a class="image-lightbox lightbox-gallery" title="" href="https://rapid-tech.com.au/wp-content/uploads/2021/08/Keysight-DAQ970A-DAQ973A-c1.jpg">						<div class="img-inner dark" >
			<img loading="lazy" decoding="async" width="999" height="562" src="https://rapid-tech.com.au/wp-content/uploads/2021/08/Keysight-DAQ970A-DAQ973A-c1.jpg" class="attachment-large size-large" alt="Keysight DAQ970A-DAQ973A-chart 2" srcset="https://rapid-tech.com.au/wp-content/uploads/2021/08/Keysight-DAQ970A-DAQ973A-c1.jpg 999w, https://rapid-tech.com.au/wp-content/uploads/2021/08/Keysight-DAQ970A-DAQ973A-c1-300x169.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2021/08/Keysight-DAQ970A-DAQ973A-c1-768x432.jpg 768w, https://rapid-tech.com.au/wp-content/uploads/2021/08/Keysight-DAQ970A-DAQ973A-c1-600x338.jpg 600w" sizes="auto, (max-width: 999px) 100vw, 999px" />						
					</div>
						</a>		
<style>
#image_459988337 {
  width: 100%;
}
</style>
	</div>
	
		</div>
					</div>

	
</div>
	<section class="section hide-for-small" id="section_9682075">
		<div class="bg section-bg fill bg-fill  bg-loaded" >

			
			
			

		</div>

		

		<div class="section-content relative">
			
<div class="row"  id="row-1912634131">

	<div id="col-916054702" class="col medium-6 small-12 large-6"  >
				<div class="col-inner"  >
			
			
<h4><span style="font-weight: 400;">Explore how to measure thermistors on a temperature cube using a DAQ970A/DAQ973A combined with a DAQM901A multiplex module, and observe how the fan impacts the system.</span></h4>
<p><span style="font-weight: 400;">You can also use DAQ systems to measure:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">AC to DC power converters</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Battery packs</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Medical devices</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Radio communication devices and more</span></li>
</ul>
		</div>
					</div>

	

	<div id="col-1139844083" class="col medium-6 small-12 large-6"  >
				<div class="col-inner"  >
			
			
<div class="video video-fit mb" style="padding-top:56.25%;"><div class="epyt-video-wrapper"><iframe loading="lazy"  id="_ytid_11291"  width="1020" height="574"  data-origwidth="1020" data-origheight="574"  data-relstop="1" src="https://www.youtube.com/embed/WdxQ1kfOEO0?enablejsapi=1&#038;autoplay=0&#038;cc_load_policy=0&#038;cc_lang_pref=&#038;iv_load_policy=1&#038;loop=0&#038;rel=0&#038;fs=1&#038;playsinline=1&#038;autohide=2&#038;theme=dark&#038;color=red&#038;controls=1&#038;disablekb=0&#038;" class="__youtube_prefs__  epyt-is-override  no-lazyload" title="How to Make Temperature Measurements with a DAQ"  allow="fullscreen; accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen data-no-lazy="1" data-skipgform_ajax_framebjll=""></iframe></div>
</div>
		</div>
					</div>

	
</div>
<h3><span style="font-weight: 400;">Keysight DAQ970A/DAQ973A modules-at-a-glance selection guide</span></h3>
<table>
<tbody>
<tr>
<td><strong>Model description</strong></td>
<td><strong>Type</strong></td>
<td><strong>Speed (ch/sec)</strong></td>
<td><strong>Max volts</strong></td>
<td><strong>Max amps</strong></td>
<td><strong>Bandwidth</strong></td>
<td><strong>Thermal offset</strong></td>
<td><strong>Comments</strong></td>
</tr>
<tr>
<td><strong>DAQM900A</strong></p>
<p><span style="font-weight: 400;">20 ch Multiplexer</span></td>
<td><span style="font-weight: 400;">2-wire solid state</span></p>
<p><span style="font-weight: 400;">(4-wire selectable)</span></td>
<td><span style="font-weight: 400;">450</span></td>
<td><span style="font-weight: 400;">120 V</span></td>
<td><span style="font-weight: 400;">20 mA</span></td>
<td><span style="font-weight: 400;">10 MHz</span></td>
<td><span style="font-weight: 400;">&lt; 4 µV</span></td>
<td><span style="font-weight: 400;">Built-in cold junction reference</span></td>
</tr>
<tr>
<td><strong>DAQM901A</strong></p>
<p><span style="font-weight: 400;">20 ch Multiplexer</span></p>
<p><span style="font-weight: 400;">+ 2 current channels</span></td>
<td><span style="font-weight: 400;">2-wire armature</span></p>
<p><span style="font-weight: 400;">(4-wire selectable)</span></td>
<td><span style="font-weight: 400;">80</span></td>
<td><span style="font-weight: 400;">300 V</span></td>
<td><span style="font-weight: 400;">1 A</span></td>
<td><span style="font-weight: 400;">10 MHz</span></td>
<td><span style="font-weight: 400;">0 µV</span></td>
<td><span style="font-weight: 400;">Built-in cold junction reference 2 additional current channels (22 total)</span></td>
</tr>
<tr>
<td><strong>DAQM902A</strong></p>
<p><span style="font-weight: 400;">16 ch Multiplexer</span></td>
<td><span style="font-weight: 400;">2-wire reed</span></p>
<p><span style="font-weight: 400;">(4-wire selectable)</span></td>
<td><span style="font-weight: 400;">250</span></td>
<td><span style="font-weight: 400;">300 V</span></td>
<td><span style="font-weight: 400;">50 mA</span></td>
<td><span style="font-weight: 400;">10 MHz</span></td>
<td><span style="font-weight: 400;">&lt; 4 µV</span></td>
<td><span style="font-weight: 400;">Built-in cold junction</span></p>
<p><span style="font-weight: 400;">reference</span></td>
</tr>
<tr>
<td><strong>DAQM903A</strong></p>
<p><span style="font-weight: 400;">20 ch Actuator/GP</span></p>
<p><span style="font-weight: 400;">Switch</span></td>
<td><span style="font-weight: 400;">SPDT/form C</span></td>
<td><span style="font-weight: 400;">120</span></td>
<td><span style="font-weight: 400;">300 V</span></td>
<td><span style="font-weight: 400;">1 A</span></td>
<td><span style="font-weight: 400;">10 MHz</span></td>
<td><span style="font-weight: 400;">&lt; 1 µV</span></td>
<td></td>
</tr>
<tr>
<td><strong>DAQM904A</strong></p>
<p><span style="font-weight: 400;">4 x 8 Matrix</span></td>
<td><span style="font-weight: 400;">2-wire armature</span></td>
<td><span style="font-weight: 400;">120</span></td>
<td><span style="font-weight: 400;">300 V</span></td>
<td><span style="font-weight: 400;">1 A</span></td>
<td><span style="font-weight: 400;">10 MHz</span></td>
<td><span style="font-weight: 400;">&lt; 1 µV</span></td>
<td></td>
</tr>
<tr>
<td><strong>DAQM905A</strong></p>
<p><span style="font-weight: 400;">Dual 4 ch RF Mux</span></p>
<p><span style="font-weight: 400;">50 Ω</span></td>
<td><span style="font-weight: 400;">Common low</span></p>
<p><span style="font-weight: 400;">(unterminated)</span></td>
<td><span style="font-weight: 400;">60</span></td>
<td><span style="font-weight: 400;">42 V</span></td>
<td><span style="font-weight: 400;">0.7 A</span></td>
<td><span style="font-weight: 400;">2 GHz</span></td>
<td><span style="font-weight: 400;">&lt; 4 µV</span></td>
<td><span style="font-weight: 400;">1 GHz bandwidth through</span></p>
<p><span style="font-weight: 400;">BNC-to-SMB adapter cable</span></td>
</tr>
<tr>
<td rowspan="3"><strong>DAQM907A</strong></p>
<p><span style="font-weight: 400;">Multifunction Module</span></td>
<td><span style="font-weight: 400;">Two 8-bit digital I/O</span></p>
<p><span style="font-weight: 400;">ports</span></td>
<td></td>
<td><span style="font-weight: 400;">42 V</span></td>
<td><span style="font-weight: 400;">400 mA</span></td>
<td></td>
<td></td>
<td><span style="font-weight: 400;">Open drain</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">26-bit event counter</span></td>
<td></td>
<td><span style="font-weight: 400;">42 V</span></td>
<td></td>
<td><span style="font-weight: 400;">100 MHz</span></td>
<td></td>
<td><span style="font-weight: 400;">Selectable input threshold</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Two 16-bit analog</span></p>
<p><span style="font-weight: 400;">outputs</span></td>
<td></td>
<td><span style="font-weight: 400;">± 12 V</span></td>
<td><span style="font-weight: 400;">10 mA</span></td>
<td><span style="font-weight: 400;">DC</span></td>
<td></td>
<td><span style="font-weight: 400;">Max 40 mA total output per</span></p>
<p><span style="font-weight: 400;">frame</span></td>
</tr>
<tr>
<td><strong>DAQM908A</strong></p>
<p><span style="font-weight: 400;">40 ch Single-Ended Mux</span></td>
<td><span style="font-weight: 400;">1-wire armature</span></p>
<p><span style="font-weight: 400;">(common low)</span></td>
<td><span style="font-weight: 400;">100</span></td>
<td><span style="font-weight: 400;">300 V</span></td>
<td><span style="font-weight: 400;">1 A</span></td>
<td><span style="font-weight: 400;">10 MHz</span></td>
<td></td>
<td><span style="font-weight: 400;">No four-wire measurements</span></td>
</tr>
<tr>
<td><strong>DAQM909A</strong></p>
<p><span style="font-weight: 400;">4 ch Digitizer</span></td>
<td><span style="font-weight: 400;">Simultaneous sampling</span></td>
<td><span style="font-weight: 400;">800</span></p>
<p><span style="font-weight: 400;">kSa/s <span style="font-size: 75%;">*</span></span><span style="font-weight: 400; font-size: 75%;">1</span></td>
<td><span style="font-weight: 400;">36 Vpk</span></td>
<td></td>
<td></td>
<td></td>
<td><span style="font-weight: 400;">24-bit resolution, differential inputs</span></td>
</tr>
<tr>
<td colspan="8"><span style="font-weight: 400;">*1. Sampling rate.</span></td>
</tr>
</tbody>
</table>
		</div>

		
<style>
#section_9682075 {
  padding-top: 30px;
  padding-bottom: 30px;
}
</style>
	</section>
	
<p>The post <a href="https://rapid-tech.com.au/data-acquisition-system-keysight-daq970a-daq973a/">Data Acquisition System | Keysight DAQ970A | DAQ973A</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
