<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Process Calibrators Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/process-calibrators-presys-instruments/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/process-calibrators-presys-instruments/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Wed, 18 Sep 2024 01:49:47 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.10</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>Process Calibrators Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/process-calibrators-presys-instruments/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Presys MCS-XV-IS  -&#124; Intrinsically Safe Multifunction Process Calibrator &#124; Ex ia IIC T4 Ga</title>
		<link>https://rapid-tech.com.au/presys-mcs-xv-is-intrinsically-safe-multifunction-process-calibrator-ex-ia-iic-t4-ga/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Wed, 08 Feb 2023 04:09:42 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=25984</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg"><img class="alignnone size-full wp-image-5972" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg" alt="" width="265" height="64" /></a></p>
<p><a target="_blank" href="https://mymeter.com.au/product/presys-mcs-xv-is-intrinsically-safe-multifunction-process-calibrator-ex-ia-iic-t4-ga" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<p>The Presys MCS-XV-IS Intrinsically Safe Multifunction Process Calibrator is a powerful, versatile tool ideal for instrumentation professionals. The exceptional performance of this high-quality calibrator empowers users with access to all types of signals, from electrical to temperature and frequency readings. It also offers outstanding pressure management capabilities with an optional barometric reference and the capacity to handle up to four pressure sensors that range from 250 mmH2O to 10,000 psi.</p>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png"><img class="alignnone size-full wp-image-19718" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" /></a>  <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2023/02/PRESYS-MCS-XV-IS-Datasheet.pdf" rel="noopener">PRESYS MCS-XV-IS Datasheet</a>     <a href="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png"><img class="alignnone size-full wp-image-19718" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" /></a> <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2023/02/Presys-MCS-XV-IS-User-Manual-.pdf" rel="noopener">Presys MCS-XV-IS User Manual</a></h4>
<p>The post <a href="https://rapid-tech.com.au/presys-mcs-xv-is-intrinsically-safe-multifunction-process-calibrator-ex-ia-iic-t4-ga/">Presys MCS-XV-IS  -| Intrinsically Safe Multifunction Process Calibrator | Ex ia IIC T4 Ga</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Presys MCS-XV-IS is an intrinsically safe multifunction process calibrator that operates a variety of instrumentation signals: electrical, temperature, frequency, and pressure up to four pressure sensors from 250 mmH2O to 10.000 psi.</p>
<p class="">It features a touchscreen display for easy-to-read data with the ability to show two variables simultaneously. The intuitive menu navigation helps users identify information for any operational mode and provides full Hart configurator (optional) capability for configuring all available HART® devices using the DD library from FieldComm Group.</p>
<p>Additionally, this reliable device offers 15 Vdc power supply for 2 wire transmitters as well as 250W internal resistor configuration capabilities, along with data logger functions for data acquisition and graphical visualization plus Wi-Fi USB connection Host / Device options and automated calibration report generation on direct connected printers or a PDF file via pen drive connections.</p>
<p>With its top-notch components and impeccable manufacturing processes, this invaluable Presys MCS-XV-IS offers the ultimate in durability that is sure to last for years &#8211; all while graciously saving you costs.</p>
<p>The post <a href="https://rapid-tech.com.au/presys-mcs-xv-is-intrinsically-safe-multifunction-process-calibrator-ex-ia-iic-t4-ga/">Presys MCS-XV-IS  -| Intrinsically Safe Multifunction Process Calibrator | Ex ia IIC T4 Ga</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PRESYS TC-512 Temperature Calibrator</title>
		<link>https://rapid-tech.com.au/presys-tc-512-temperature-calibrator/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 28 Apr 2020 23:08:25 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=15018</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg"><img class="alignnone size-full wp-image-5972" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg" alt="" width="265" height="64" /></a></p>
<p>The PRESYS TC-512 Temperature Calibrator enables measurement and generation of signals used in instrumentation and Process Control.</p>
<p>It is a high-accuracy instrument, having high stability features in temperature changes and long-term aging conditions.</p>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/04/Presys-TC-512-Datasheet.pdf" rel="noopener noreferrer">Presys TC-512 Datasheet</a></span></h3>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/04/Presys-TC-512-User-Manual.pdf" rel="noopener noreferrer">Presys TC-512 User Manual</a></span></h3>
<p>The post <a href="https://rapid-tech.com.au/presys-tc-512-temperature-calibrator/">PRESYS TC-512 Temperature Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The PRESYS TC-512 Temperature Calibrator enables measurement and generation of signals used in instrumentation and Process Control. It is a high-accuracy instrument, having high stability features in temperature changes and long-term aging conditions.</p>
<p>The TC-512 Probe input calculates the temperature based on international standard tables, in IPTS-68 and ITS-90 scales, and also has algorithms that calculate temperatures using Callendar-Van Dusen coefficients from a calibrated sensor.</p>
<p>PRESYS TC-512 Temperature Calibrator contains useful items allowing its on field and workbench use. The TC-512 also incorporates concepts of automatic checking and calibration via computer, such as report and certificate issues, automatic work management, data archiving for an overall coverage of quality procedure requirements.</p>
<p>Additionally, various optional modules are available, intended to perform pressure and temperature measurements.</p>
<h4>PRESYS TC-512 Temperature Calibrator Features:</h4>
<ul id="produto">
<li>Measures and generates mA, mV, volts, ohms, RTD and TC.</li>
<li>Simultaneous input and output operation.</li>
<li>Isolated input and output.</li>
<li>Interface with a Windows-based Calibration Software to provide a true Computer-Aided Calibration System with documenting capability.</li>
<li>Real-time data acquisition capability when connected to a computer.</li>
<li>Callendar-Van Dunsen coeficientes for Probe input.</li>
</ul>
<p>&nbsp;</p>
<p>The post <a href="https://rapid-tech.com.au/presys-tc-512-temperature-calibrator/">PRESYS TC-512 Temperature Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PRESYS MCS-12-IS Multifunction Intrinsically Safe Process Calibrator</title>
		<link>https://rapid-tech.com.au/presys-mcs-12-is-multifunction-intrinsically-safe-process-calibrator/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 28 Apr 2020 01:13:48 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=15014</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg"><img class="alignnone size-full wp-image-5972" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg" alt="" width="265" height="64" /></a></p>
<p>The PRESYS MCS-12-IS is a documenting multifunction calibrator that enables measurement and generation of signals used in Instrumentation and Process Control.</p>
<p>It is portable, compact and ideal for field use with performance levels comparable to laboratory standards.</p>
<p>The MCS-12-IS communicates with ISOPLAN® Calibration Software in a Windows™ environment providing a true Document Assisted Calibration System.</p>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/04/Presys-MCS-12-IS-Datasheet.pdf" rel="noopener noreferrer">Presys MCS-12-IS Datasheet</a></span></h3>
<p>The post <a href="https://rapid-tech.com.au/presys-mcs-12-is-multifunction-intrinsically-safe-process-calibrator/">PRESYS MCS-12-IS Multifunction Intrinsically Safe Process Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The PRESYS MCS-12-IS Multifunction Intrinsically Safe Process Calibrator has been approved for use in hazardous areas.<br />
The MCS-12-IS is approved as intrinsically safe and can be operated in the Group IIC Zone 0, which is the most demanding regarding the need for protection against electric sparks, is the group of hydrogen and acetylene.</p>
<p>The Probe input calculates temperatures based on standard international tables on the IPTS-68 and ITS-90 scales and also has internal algorithms that calculate temperatures using Callendar-Van Dusen coefficients from a sensor calibration. It has useful items that allow it to be used in the field and on a bench.</p>
<p>The calibrator also incorporates automatic computer calibration concepts, such as report and certificate issuance, automatic task management, organization and data archiving to meet the requirements of quality procedures.</p>
<h3>PRESYS MCS-12-IS Features</h3>
<ul>
<li>Intrinsically safe Universal Process Calibrator Certified Ex ia IIC T4 Ga for usage in Ex-hazardous areas Zones 0,1 and 2.</li>
<li>Portable, compact, powered by rechargeable batteries.</li>
<li>Measures and generates mA, mV, volts, ohms, RTD, TC and Hz.</li>
<li>Simultaneous input and output operation. 12 Vcc/ 30 mA Power supply for 2-wire transmitters. Includes input for optional temperature probe.</li>
<li>Callendar-Van Dunsen coeficientes for Probe input.</li>
</ul>
<p>&nbsp;</p>
<p>The post <a href="https://rapid-tech.com.au/presys-mcs-12-is-multifunction-intrinsically-safe-process-calibrator/">PRESYS MCS-12-IS Multifunction Intrinsically Safe Process Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Documenting Process Calibrator With Full HART Communicator &#124; PRESYS MCS-XV</title>
		<link>https://rapid-tech.com.au/presys-mcs-xv-documenting-process-calibrator/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Mon, 23 Apr 2018 18:02:08 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=7267</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg"><img class="alignnone size-full wp-image-5972" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg" alt="" width="265" height="64" /></a></p>
<h3>PRESYS MCS-XV Documenting Process Calibrator Features:</h3>
<ul id="produto">
<li>Measures and generates <strong>mA, mV, Volts, ohms, RTD, TC, and Hz</strong> with accuracy <strong>0.01%</strong> up to full scale.</li>
<li>Up to four optional Pressure modules of <strong>250 mmH<sub>2</sub>O pressure to 10,000 psi</strong>. It has the barometric reference (optional) for absolute pressure indication.</li>
<li>Hart Full Configurator (optional). Compatible with DD configuration files recorded in FieldComm Group.</li>
<li>24Vdc power supply for two-wire transmitter. internal 250 ohms resistor configurable.</li>
<li>Documentation capability. Automatic calibration tasks can be created or executed with or without the use of computers.</li>
<li>Calibration Reports issued directly to USB printer or PDF file.</li>
<li>Data logger function for data acquisition and display in graphical format.</li>
<li>Touchscreen display with high visibility friendly interface.</li>
<li>Compact, portable, powered by rechargeable batteries for field use.</li>
<li>Also available in versions <strong>Desktop (DT) and 19" Rack Mounting (RM).</strong></li>
<li>e-Connected: Ethernet, Wi-Fi (optional), Pen-drive, Hart, Profibus*, Fieldbus Foundation*, Modbus* and USB Host/Device</li>
<li>Similar to Fluke 754 Documenting Process Calibrator and Emerson TREX Communicator</li>
</ul>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2017/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-5148" src="https://rapid-tech.com.au/wp-content/uploads/2017/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="color: #0000ff;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-MCS-XV-Datasheet.pdf" rel="noopener">Presys MCS-XV Datasheet</a></span></h3>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="color: #0000ff;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-MCS-XV-User-Manual.pdf" rel="noopener">Presys MCS-XV User Manual</a></span></h3>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/presys-mcs-xv-documenting-process-calibrator/">Documenting Process Calibrator With Full HART Communicator | PRESYS MCS-XV</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The PRESYS MCS-XV Documenting Process Calibrator with HART Communicator enables measurement and generation of signals used in instrumentation and process control. It provides all the features required for easier calibration and adjustment services on process instruments. It has high levels of accuracy, including aspects relating to changes in room temperature and maintains the specifications over long periods of time. It is similar in function to the Fluke 754 Documenting Process Calibrator.</p>
<p>The PRESYS MCS-XV Documenting Process Calibrator with HART Communicator is <strong>designed for field use</strong> and includes: carrying case, holders with fastener rings or belts for a hands-free operation, 5.7” display with LED backlight for a better viewing in poor lighting conditions, rechargeable battery and large memory capacity to store the values obtained during calibrations enabling the transfer of these to the PC when needed.</p>
<p>In addition to these features the PRESYS MCS-XV with HART Communicator is available in a <strong>19&#8243; Rack Mount version</strong> (RM) or as a <strong>Desktop Instrument</strong> (DT).</p>
<p>The PRESYS MCS-XV Documenting Process Calibrator incorporates state-of-the-art concepts of automatic calibration and adjustment via computer. Instrument and computer share measurement data obtained for a more efficient handling of information such as report and certificate issues, automatic work management, data sorting and storage, for an overall coverage of quality procedure requirements, especially those related to ISO-9000.</p>
<p>The PRESYS MCS-XV has HART communication for reading and setting parameters of field devices that have this protocol and can be supplied with up to four pressure sensors. Thus, a single calibrator can have different ranges of pressure, for example vacuum, 0 to 100 psi, 0 to 1,000 psi and 0 to 3,000 psi, or any combination of available ranges.</p>
<figure id="attachment_5985" aria-describedby="caption-attachment-5985" style="width: 635px" class="wp-caption aligncenter"><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-MCSXV-Operator.jpg"><img fetchpriority="high" decoding="async" class="size-full wp-image-5985" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-MCSXV-Operator.jpg" alt="" width="635" height="364" srcset="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-MCSXV-Operator.jpg 635w, https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-MCSXV-Operator-300x172.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-MCSXV-Operator-600x344.jpg 600w" sizes="(max-width: 635px) 100vw, 635px" /></a><figcaption id="caption-attachment-5985" class="wp-caption-text">Presys MCS-XV Portable version in use.</figcaption></figure>
<h3>PRESYS MCS-XV Documenting Process Calibrator Specifications:</h3>
<div>
<table style="height: 13px;" border="0" width="998" cellspacing="0" cellpadding="5">
<thead>
<tr>
<td class="center" colspan="2">Ranges</td>
<td class="center">Resolution</td>
<td class="center">Accuracy</td>
<td class="center">Remarks</td>
</tr>
</thead>
</table>
</div>
<div>
<table border="0" cellspacing="0" cellpadding="0">
<colgroup>
<col width="5%" />
<col width="15%" />
<col width="25%" />
<col width="17%" />
<col width="17%" />
<col width="21%" /></colgroup>
<tbody>
<tr>
<td></td>
<td colspan="6"><b>Specifications &#8211; Inputs</b></td>
</tr>
<tr>
<th rowspan="38"><img decoding="async" src="https://www.mcsxv.com/images/entradas_en.png" width="25px" border="0" /></th>
<td><b>milivolt</b></td>
<td>-150 to 150 mV</td>
<td>0.001 mV</td>
<td>± 0.01 % FS <sup>***</sup></td>
<td>R<sub>input</sub> &gt; 10 MΩ</td>
</tr>
<tr>
<td></td>
<td>-500 to -150 mV</td>
<td>0.01 mV</td>
<td>± 0.02 % FS</td>
<td>auto-ranging</td>
</tr>
<tr>
<td></td>
<td>150 to 2450 mV</td>
<td>0.01 mV</td>
<td>± 0.02 % FS</td>
<td></td>
</tr>
<tr>
<td><b>volt</b></td>
<td>-10 to 45 V</td>
<td>0.0001 V</td>
<td>± 0.02 % FS</td>
<td>R<sub>input</sub> &gt; 1 MΩ</td>
</tr>
<tr>
<td><b>mA</b></td>
<td>-5 to 24.5 mA</td>
<td>0.0001 mA</td>
<td>± 0.02 % FS</td>
<td>R<sub>input</sub> &lt; 120Ω</td>
</tr>
<tr>
<td><b>resistance</b></td>
<td>0 to 400 Ω</td>
<td>0.01 Ω</td>
<td>± 0.01 % FS</td>
<td>Excitation current 0.85 mA</td>
</tr>
<tr>
<td></td>
<td>400 to 2500 Ω</td>
<td>0.01 Ω</td>
<td>± 0.03 % FS</td>
<td>auto-ranging</td>
</tr>
<tr>
<td><b>frequency<sup>*</sup></b></td>
<td>0 to 600 Hz</td>
<td>0.01 Hz</td>
<td>± 0.04 Hz</td>
<td>R<sub>input</sub> &gt; 50KΩ</td>
</tr>
<tr>
<td></td>
<td>600 to 1300 Hz</td>
<td>0.1 Hz</td>
<td>± 0.2 Hz</td>
<td>Voltage DC<sub>max</sub> = 30 V</td>
</tr>
<tr>
<td></td>
<td valign="top">1300 to 5000 Hz</td>
<td valign="top">1 Hz</td>
<td valign="top">± 2 Hz</td>
<td>AC Signal from 0.3 to 30 V<br />
auto-ranging</td>
</tr>
<tr>
<td valign="top"><b>counter<sup>*</sup></b></td>
<td valign="top">0 to 10<sup>8</sup> -1 count</td>
<td valign="top">1 count</td>
<td valign="top"></td>
<td valign="top">The same remark as frequency Pulses Frequency &lt; 3000 Hz</td>
</tr>
<tr>
<td><b>Pt-100</b></td>
<td>-200 to 850 °C / -328 to 1562 °F</td>
<td>0.01 °C / 0.01 °F</td>
<td>± 0.1 °C / ± 0.2 °F</td>
<td>IEC-60751</td>
</tr>
<tr>
<td><b>Pt-1000</b></td>
<td>-200 to 400 °C / -328 to 752 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.1 °C / ± 0.2 °F</td>
<td>IEC-60751</td>
</tr>
<tr>
<td><b>Cu-10</b></td>
<td>-200 to 260 °C / -328 to 500 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 2.0 °C / ± 4.0 °F</td>
<td>Minco 16-9</td>
</tr>
<tr>
<td><b>Ni-100</b></td>
<td>-60 to 250 °C / -76 to 482 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.2 °C / ± 0.4 °F</td>
<td>DIN-43760</td>
</tr>
<tr>
<td><b>probe<sup>**</sup></b></td>
<td>-200 to 850 °C / -328 to 1562 °F</td>
<td>0.01 °C / 0.01 °F</td>
<td>± 0.1 °C / ± 0.2 °F</td>
<td>IEC-60751</td>
</tr>
<tr>
<td><b>TC-J</b></td>
<td>-210 to 1200 °C / -346 to 2192 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.2 °C / ± 0.4 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td><b>TC-K</b></td>
<td>-270 to -150 °C / -454 to -238 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.5 °C / ± 1.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>-150 to 1370 °C / -238 to 2498 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.2 °C / ± 0.4 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-T</b></td>
<td>-260 to -200 °C / -436 to -328 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.6 °C / ± 1.2 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>-200 to -75 °C / -328 to -103 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.4 °C / ± 0.8 °F</td>
<td></td>
</tr>
<tr>
<td></td>
<td>-75 to 400 °C / -103 to 752 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.2 °C / ± 0.4 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-B</b></td>
<td>50 to 250 °C / 122 to 482 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 2.5 °C / ± 5.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>250 to 500 °C / 482 to 932 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.5 °C / ± 3.0 °F</td>
<td></td>
</tr>
<tr>
<td></td>
<td>500 to 1200 °C / 932 to 2192 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.0 °C / ± 2.0 °F</td>
<td></td>
</tr>
<tr>
<td></td>
<td>1200 to 1820 °C / 2192 to 3308 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.7 °C / ± 1.4 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-R</b></td>
<td>-50 to 300 °C / -58 to 572 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.0 °C / ± 2.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>300 to 1760 °C / 572 to 3200 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.7 °C / ± 1.4 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-S</b></td>
<td>-50 to 300 °C / -58 to 572 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.0 °C / ± 2.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>300 to 1760 °C / 572 to 3200 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.7 °C / ± 1.4 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-E</b></td>
<td>-270 to -150 °C / -454 to -238 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.3 °C / ± 0.6 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>-150 to 1000 °C / -238 to 1832 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.1 °C / ± 0.2 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-N</b></td>
<td>-260 to -200 °C / -436 to -328 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.0 °C / ± 2.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>-200 to -20 °C / -328 to -4 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.4 °C / ± 0.8 °F</td>
<td></td>
</tr>
<tr>
<td></td>
<td>-20 to 1300 °C / -4 to 2372 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.2 °C / ± 0.4 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-L</b></td>
<td>-200 to 900 °C / -328 to 1652 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.2 °C / ± 0.4 °F</td>
<td>DIN-43710</td>
</tr>
<tr>
<td><b>TC-C</b></td>
<td>0 to 1500 °C / 32 to 2732 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.5 °C / ± 1.0 °F</td>
<td>W5Re / W26Re</td>
</tr>
<tr>
<td></td>
<td>1500 to 2320 °C / 2732 to 4208 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.7 °C / ± 1.4 °F</td>
<td></td>
</tr>
<tr>
<td colspan="6">(*) Accuracy valid since the frequency output is not configured.<br />
(**) The Probe is a separate input used as reference thermometer. The related accuracy is relative only to the MCS-XV.<br />
(***) FS = Full Scale.</td>
</tr>
</tbody>
</table>
<table border="0" cellspacing="0" cellpadding="0">
<colgroup>
<col width="5%" />
<col width="15%" />
<col width="25%" />
<col width="17%" />
<col width="17%" />
<col width="21%" /></colgroup>
<tbody>
<tr>
<td></td>
<td colspan="6"><b>Specifications &#8211; Outputs</b></td>
</tr>
<tr>
<th rowspan="35"><img decoding="async" src="https://www.mcsxv.com/images/saidas_en.png" width="25px" border="0" /></th>
<td><b>milivolt</b></td>
<td>-10 to 110 mV</td>
<td>0.001 mV</td>
<td>± 0.02 % FS <sup>***</sup></td>
<td>R<sub>out</sub> &lt; 0.3 Ω</td>
</tr>
<tr>
<td><b>volt</b></td>
<td>-0.5 to 12 V</td>
<td>0.0001 V</td>
<td>± 0.02 % FS</td>
<td>R<sub>out</sub> &lt; 0.3 Ω</td>
</tr>
<tr>
<td><b>mA</b></td>
<td>0 to 24 mA</td>
<td>0.0001 mA</td>
<td>± 0.02 % FS</td>
<td>R<sub>max</sub> = 700 Ω</td>
</tr>
<tr>
<td><b>2-wire transmitter (XTR)</b></td>
<td>4 to 24 mA</td>
<td>0.0001 mA</td>
<td>± 0.02 % FS</td>
<td>V<sub>max</sub> = 60 V</td>
</tr>
<tr>
<td valign="top"><b>resistance</b></td>
<td valign="top">0 to 400 Ω</td>
<td valign="top">0.01 Ω</td>
<td valign="top">± 0.02 % FS</td>
<td valign="top">For external excitation current<br />
of 1.0 mA</td>
</tr>
<tr>
<td></td>
<td>0 to 2500 Ω</td>
<td>0.1 Ω</td>
<td>± 0.03 % FS</td>
<td></td>
</tr>
<tr>
<td><b>frequency</b></td>
<td>0 to 100 Hz</td>
<td>0.01 Hz</td>
<td>± 0.02 Hz</td>
<td>Peak value:</td>
</tr>
<tr>
<td></td>
<td>0 to 10000 Hz</td>
<td>1 Hz</td>
<td>± 2 Hz</td>
<td>22 V / 25 mA max.</td>
</tr>
<tr>
<td valign="top"><b>pulse</b></td>
<td valign="top">0 to 10<sup>8</sup> &#8211; 1 pulse</td>
<td valign="top">1 pulse</td>
<td valign="top"></td>
<td valign="top">Peak value:<br />
22 V / 25 mA max.<br />
Pulses frequency up to 10000 Hz</td>
</tr>
<tr>
<td><b>Pt-100</b></td>
<td>-200 to 850 °C / -328 to 1562 °F</td>
<td>0.01 °C / 0.01 °F</td>
<td>± 0.2 °C / ± 0.4 °F</td>
<td>IEC-60751</td>
</tr>
<tr>
<td><b>Pt-1000</b></td>
<td>-200 to 400 °C / -328 to 752 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.1 °C / ± 0.2 °F</td>
<td>IEC-60751</td>
</tr>
<tr>
<td><b>Cu-10</b></td>
<td>-200 to 260 °C / -328 to 500 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 2.0 °C / ± 4.0 °F</td>
<td>Minco 16-9</td>
</tr>
<tr>
<td><b>Ni-100</b></td>
<td>-60 to 250 °C / -76 to 482 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.2 °C / ± 0.4 °F</td>
<td>DIN-43760</td>
</tr>
<tr>
<td><b>TC-J</b></td>
<td>-210 to 1200 °C / -346 to 2192 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.4 °C / ± 0.8 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td><b>TC-K</b></td>
<td>-270 to -150 °C / -454 to -238 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.0 °C / ± 2.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>-150 to 1370 °C / -238 to 2498 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.4 °C / ± 0.8 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-T</b></td>
<td>-260 to -200 °C / -436 to -328 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.2 °C / ± 2.4 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>-200 to -75 °C / -328 to -103 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.8 °C / ± 1.6 °F</td>
<td></td>
</tr>
<tr>
<td></td>
<td>-75 to 400 °C / -103 to 752 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.4 °C / ± 0.8 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-B</b></td>
<td>50 to 250 °C / 122 to 482 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 5.0 °C / ± 10.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>250 to 500 °C / 482 to 932 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 3.0 °C / ± 6.0 °F</td>
<td></td>
</tr>
<tr>
<td></td>
<td>500 to 1200 °C / 932 to 2192 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 2.0 °C / ± 4.0 °F</td>
<td></td>
</tr>
<tr>
<td></td>
<td>1200 to 1820 °C / 2192 to 3308 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.4 °C / ± 2.8 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-R</b></td>
<td>-50 to 300 °C / -58 to 572 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 2.0 °C / ± 4.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>300 to 1760 °C / 572 to 3200 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.4 °C / ± 2.8 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-S</b></td>
<td>-50 to 300 °C / -58 to 572 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 2.0 °C / ± 4.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>300 to 1760 °C / 572 to 3200 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.4 °C / ± 2.8 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-E</b></td>
<td>-270 to -150 °C / -454 to -238 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.6 °C / ± 1.2 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>-150 to 1000 °C / -238 to 1832 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.2 °C / ± 0.4 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-N</b></td>
<td>-260 to -200 °C / -436 to -328 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 2.0 °C / ± 4.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>-200 to -20 °C / -328 to -4 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.8 °C / ± 1.6 °F</td>
<td></td>
</tr>
<tr>
<td></td>
<td>-20 to 1300 °C / -4 to 2372 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.4 °C / ± 0.8 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-L</b></td>
<td>-200 to 900 °C / -328 to 1652 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.4 °C / ± 0.8 °F</td>
<td>DIN-43710</td>
</tr>
<tr>
<td><b>TC-C</b></td>
<td>0 to 1500 °C / 32 to 2732 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.5 °C / ± 1.0 °F</td>
<td>W5Re / W26Re</td>
</tr>
<tr>
<td></td>
<td>1500 to 2320 °C / 2732 to 4208 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.7 °C / ± 1.4 °F</td>
<td></td>
</tr>
<tr>
<td colspan="6">The values of accuracy cover one year period and for a temperature range between 20 and 26 °C. Outside this range, the thermal stability is 0.001% FS / °C with reference<br />
to 23 °C. Thermocouple with internal cold junction compensation, one must consider the error of this cold junction compensation of up to ± 0.2 °C or ± 0.4 °F.</td>
</tr>
</tbody>
</table>
<table border="0" cellspacing="0" cellpadding="0">
<colgroup>
<col width="5%" />
<col width="15%" />
<col width="25%" />
<col width="17%" />
<col width="17%" />
<col width="21%" /></colgroup>
<tbody>
<tr>
<td></td>
<td colspan="6"><b>Specifications &#8211; Pressure</b></td>
</tr>
<tr>
<th rowspan="13"><img decoding="async" src="https://www.mcsxv.com/images/pressao_en.png" width="22" border="0" /></th>
<td><b>(0)</b></td>
<td>0 &#8211; 250 mmH20</td>
<td>0,001</td>
<td>± 0,05 % FS</td>
<td rowspan="3">Gage pressure.<br />
Used with air or inert gases.</td>
</tr>
<tr>
<td><b>(1)</b></td>
<td>0 &#8211; 1 psi</td>
<td>0,0001</td>
<td>± 0,05 % FS</td>
</tr>
<tr>
<td><b>(2)</b></td>
<td>0 &#8211; 5 psi</td>
<td>0,0001</td>
<td>± 0,025 % FS</td>
</tr>
<tr>
<td><b>(3)</b></td>
<td>0 &#8211; 15 psi</td>
<td>0,0001</td>
<td>± 0,025 % FS</td>
<td rowspan="10">Gage or absolute pressure.<br />
Used with fluids (gases or liquids) compatible with 316 L stainless steel.</td>
</tr>
<tr>
<td><b>(4)</b></td>
<td>0 &#8211; 30 psi</td>
<td>0,0001</td>
<td>± 0,025 % FS</td>
</tr>
<tr>
<td><b>(5)</b></td>
<td>0 &#8211; 100 psi</td>
<td>0,001</td>
<td>± 0,025 % FS</td>
</tr>
<tr>
<td><b>(6)</b></td>
<td>0 &#8211; 250 psi</td>
<td>0,001</td>
<td>± 0,025 % FS</td>
</tr>
<tr>
<td><b>(7)</b></td>
<td>0 &#8211; 500 psi</td>
<td>0,01</td>
<td>± 0,025 % FS</td>
</tr>
<tr>
<td><b>(8)</b></td>
<td>0 &#8211; 1000 psi</td>
<td>0,01</td>
<td>± 0,025 % FS</td>
</tr>
<tr>
<td><b>(9)</b></td>
<td>0 &#8211; 3000 psi</td>
<td>0,01</td>
<td>± 0,025 % FS</td>
<td></td>
</tr>
<tr>
<td><b>(10)</b></td>
<td>0 &#8211; 5000 psi</td>
<td>0,1</td>
<td>± 0,025 % FS</td>
</tr>
<tr>
<td><b>(11)</b></td>
<td>0 &#8211; 10000 psi</td>
<td>0,1</td>
<td>± 0,05 % FS</td>
</tr>
<tr>
<td><b>(12)</b></td>
<td>Others on request</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="6"></td>
</tr>
</tbody>
</table>
</div>
<div></div>
<p>The post <a href="https://rapid-tech.com.au/presys-mcs-xv-documenting-process-calibrator/">Documenting Process Calibrator With Full HART Communicator | PRESYS MCS-XV</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PRESYS LC-505 Process Loop Calibrator</title>
		<link>https://rapid-tech.com.au/presys-lc-505-process-loop-calibrator/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 28 Nov 2017 20:16:36 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=6070</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg"><img class="alignnone size-full wp-image-5972" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg" alt="" width="265" height="64" /></a></p>
<ul id="produto">
<li>Measures and generates standard <b>linear signals for current and voltage loops (mA and volts)</b>.</li>
<li>Designed for on-field use, it offers all advantages of a documenting calibrator.</li>
<li>Simultaneous input and output operation.</li>
<li>Internal regulated 24 Vdc power supply for 2-wire transmitters.</li>
<li>Special function for <b>transmitter calibration</b> converts any input signal into any output signal.</li>
<li>Square root function for mA input and output.</li>
<li>Generates, simulates and reads mA signals.</li>
<li>Automatic power off configuration to save battery.</li>
<li>Small, battery-operated, portable (rechargeable battery, charger and carrying case included).</li>
<li>Interfaces with Windows-based <b>Calibration Software Isoplan-5</b> to provide a true Computer-Aided Calibration System.</li>
<li>Real-time data acquisition capability when connected to a computer.</li>
</ul>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LC-505-Datasheet.pdf" rel="noopener noreferrer">PRESYS LC-505 Datasheet</a></h3>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LC-505-User-Manual.pdf" rel="noopener noreferrer">PRESYS LC-505 User Manual</a></h3>
<p style="text-align: center;"><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-Authorised.png"><img class="alignnone size-full wp-image-6055" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-Authorised.png" alt="" width="200" height="119" /></a></p>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/presys-lc-505-process-loop-calibrator/">PRESYS LC-505 Process Loop Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The PRESYS LC-505 Process Loop Calibrator enables measurement and generation of signals used in DC current (4-20mA) and voltage (1-5V, 0-10V) loops.</p>
<p>Distinguished from regular loop calibrators due to its high-accuracy, possibility of simultaneous measurement and generation of isolated signals, real time connection with computer, working as a data acquisition point and full computer-aid for instrument calibration and adjustment tasks.</p>
<p>Its accuracy refers to changes in room temperature and maintenance of specifications for a long time of use. Designed for field use, it contains useful items as carrying case holders with fastener rings or belts for a hands-free operation, a high contrast LCD for a better viewing in poor lighting conditions, besides presenting measured and generated signals with large digits so that they can be seen far away.</p>
<p>It includes rechargeable battery, and a high-size memory intended to store values obtained for a later upload to a computer, when applicable. Moreover, various other constructive features aggregate quality and efficiency to LC-505, allowing also its field and workbench use</p>
<h3>PRESYS LC-505 Process Loop Calibrator Specifications:</h3>
<table style="height: 221px;" width="771">
<tbody>
<tr>
<td width="189">
<h4><strong>Input Ranges</strong></h4>
</td>
<td width="95"><strong>Resolution</strong></td>
<td width="95"><strong>Accuracy</strong></td>
<td width="95"><strong>Remarks</strong></td>
</tr>
<tr>
<td width="189"><strong>VOLT  </strong></p>
<p>-10 to 11V</p>
<p>11 to 45V</td>
<td width="95">&nbsp;</p>
<p>0.0001 V</p>
<p>0.0001 V</td>
<td width="95">&nbsp;</p>
<p><u>+</u> 0.02% FS</p>
<p><u>+</u> 0.02% FS</td>
<td width="95">&nbsp;</p>
<p>RInput &gt;1MΩ</td>
</tr>
<tr>
<td width="189"><strong>mA </strong></p>
<p>-5 to 24.5mA</td>
<td width="95">&nbsp;</p>
<p>0.0001 mA</td>
<td width="95">&nbsp;</p>
<p><u>+</u> 0.02% FS</td>
<td width="95">&nbsp;</p>
<p>RInput &lt;160Ω</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table style="height: 315px;" width="771">
<tbody>
<tr>
<td width="183">
<h4><strong>Output Ranges</strong></h4>
</td>
<td width="92"><strong>Resolution</strong></td>
<td width="92"><strong>Accuracy</strong></td>
<td width="92"><strong>Remarks</strong></td>
</tr>
<tr>
<td width="183"><strong>VOLT </strong></p>
<p>-1 to 11V</td>
<td width="92">&nbsp;</p>
<p>0.0001 V</td>
<td width="92">&nbsp;</p>
<p><u>+</u> 0.02% FS</td>
<td width="92">&nbsp;</p>
<p>R output &lt;0.3Ω</td>
</tr>
<tr>
<td width="183"><strong>mA </strong></p>
<p>0 to 22mA</td>
<td width="92">&nbsp;</p>
<p>0.0001 mA</td>
<td width="92">&nbsp;</p>
<p><u>+</u> 0.02% FS</td>
<td width="92">&nbsp;</p>
<p>Rmax=700Ω</td>
</tr>
<tr>
<td width="183"><strong>2-Wire Transmitter (XTR) </strong></p>
<p>4mA to 22mA</td>
<td width="92">&nbsp;</p>
<p>0.0001 mA</td>
<td width="92">&nbsp;</p>
<p><u>+</u> 0.02% FS</td>
<td width="92">&nbsp;</p>
<p>V max= 60V</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>The post <a href="https://rapid-tech.com.au/presys-lc-505-process-loop-calibrator/">PRESYS LC-505 Process Loop Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PRESYS MCS-XV Universal Multifunction Process Calibrator</title>
		<link>https://rapid-tech.com.au/presys-mcs-xv-universal-multifunction-process-calibrator/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Mon, 20 Nov 2017 17:54:25 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=5981</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg"><img class="alignnone size-full wp-image-5972" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg" alt="" width="265" height="64" /></a></p>
<h3>Presys MCS-XV Universal Multifunction Process Calibrator Features:</h3>
<ul id="produto">
<li>Measures and generates <strong>mA, mV, Volts, ohms, RTD, TC, and Hz</strong> with accuracy <strong>0.01%</strong> up to full scale.</li>
<li>Up to four optional modules of <strong>250 mmH<sub>2</sub>O pressure to 10,000 psi</strong>. It has the barometric reference (optional) for absolute pressure indication.</li>
<li>Hart Full Configurator (optional). Compatible with DD configuration files recorded in FieldComm Group.</li>
<li>24Vdc power supply for two-wire transmitter. internal 250 ohms resistor configurable.</li>
<li>Documentation capability. Automatic calibration tasks can be created or executed with or without the use of computers.</li>
<li>Calibration Reports issued directly to USB printer or PDF file.</li>
<li>Data logger function for data acquisition and display in graphical format.</li>
<li>Touchscreen display with high visibility friendly interface.</li>
<li>Compact, portable, powered by rechargeable batteries for field use.</li>
<li>Also available in versions Desktop (DT) and 19" Rack Mounting (RM).</li>
<li>e-Connected: Ethernet, Wi-Fi (optional), Pen-drive, Hart, Profibus*, Fieldbus Foundation*, Modbus* and USB Host/Device</li>
</ul>
<p style="text-align: right;"><em>*Check availability</em></p>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2017/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-5148" src="https://rapid-tech.com.au/wp-content/uploads/2017/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="color: #0000ff;"><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-MCS-XV-Datasheet.pdf" target="_blank" rel="noopener">Presys MCS-XV Datasheet</a></span></h3>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="color: #0000ff;"><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-MCS-XV-User-Manual.pdf" target="_blank" rel="noopener">Presys MCS-XV User Manual</a></span></h3>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/presys-mcs-xv-universal-multifunction-process-calibrator/">PRESYS MCS-XV Universal Multifunction Process Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The PRESYS MCS-XV Process Multifunction Calibrator enables measurement and generation of signals used in instrumentation and process control. It provides all the features required for easier calibration and adjustment services on process instruments. It has high levels of accuracy, including aspects relating to changes in room temperature and maintains the specifications over long periods of time.</p>
<p>The PRESYS MCS-XV Process Multifunction Calibrator is <strong>designed for field use</strong> and includes: carrying case, holders with fastener rings or belts for a hands-free operation, 5.7” display with LED backlight for a better viewing in poor lighting conditions, rechargeable battery and large memory capacity to store the values obtained during calibrations enabling the transfer of these to the PC when needed.</p>
<p>In addition to these features the PRESYS MCS-XV is available in a <strong>19&#8243; Rack Mount version</strong> (RM) or as a <strong>Desktop Instrument</strong> (DT).</p>
<p>The PRESYS MCS-XV Universal Multifunction Process Calibrator incorporates state-of-the-art concepts of automatic calibration and adjustment via computer. Instrument and computer share measurement data obtained for a more efficient handling of information such as report and certificate issues, automatic work management, data sorting and storage, for an overall coverage of quality procedure requirements, especially those related to ISO-9000.</p>
<p>The PRESYS MCS-XV has HART® communication for reading and setting parameters of field devices that have this protocol and can be supplied with up to four pressure sensors. Thus, a single calibrator can have different ranges of pressure, for example vacuum, 0 to 100 psi, 0 to 1,000 psi and 0 to 3,000 psi, or any combination of available ranges.</p>
<figure id="attachment_5985" aria-describedby="caption-attachment-5985" style="width: 635px" class="wp-caption aligncenter"><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-MCSXV-Operator.jpg"><img decoding="async" class="size-full wp-image-5985" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-MCSXV-Operator.jpg" alt="" width="635" height="364" srcset="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-MCSXV-Operator.jpg 635w, https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-MCSXV-Operator-300x172.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-MCSXV-Operator-600x344.jpg 600w" sizes="(max-width: 635px) 100vw, 635px" /></a><figcaption id="caption-attachment-5985" class="wp-caption-text">Presys MCS-XV Portable version in use.</figcaption></figure>
<h3>Presys MCS-XV Universal Multifunction Process Calibrator Specifications:</h3>
<div>
<table style="height: 13px;" border="0" width="998" cellspacing="0" cellpadding="5">
<thead>
<tr>
<td class="center" colspan="2">Ranges</td>
<td class="center">Resolution</td>
<td class="center">Accuracy</td>
<td class="center">Remarks</td>
</tr>
</thead>
</table>
</div>
<div>
<table border="0" cellspacing="0" cellpadding="0">
<colgroup>
<col width="5%" />
<col width="15%" />
<col width="25%" />
<col width="17%" />
<col width="17%" />
<col width="21%" /></colgroup>
<tbody>
<tr>
<td></td>
<td colspan="6"><b>Specifications &#8211; Inputs</b></td>
</tr>
<tr>
<th rowspan="38"><img decoding="async" src="https://www.mcsxv.com/images/entradas_en.png" width="25px" border="0" /></th>
<td><b>milivolt</b></td>
<td>-150 to 150 mV</td>
<td>0.001 mV</td>
<td>± 0.01 % FS <sup>***</sup></td>
<td>R<sub>input</sub> &gt; 10 MΩ</td>
</tr>
<tr>
<td></td>
<td>-500 to -150 mV</td>
<td>0.01 mV</td>
<td>± 0.02 % FS</td>
<td>auto-ranging</td>
</tr>
<tr>
<td></td>
<td>150 to 2450 mV</td>
<td>0.01 mV</td>
<td>± 0.02 % FS</td>
<td></td>
</tr>
<tr>
<td><b>volt</b></td>
<td>-10 to 45 V</td>
<td>0.0001 V</td>
<td>± 0.02 % FS</td>
<td>R<sub>input</sub> &gt; 1 MΩ</td>
</tr>
<tr>
<td><b>mA</b></td>
<td>-5 to 24.5 mA</td>
<td>0.0001 mA</td>
<td>± 0.02 % FS</td>
<td>R<sub>input</sub> &lt; 120Ω</td>
</tr>
<tr>
<td><b>resistance</b></td>
<td>0 to 400 Ω</td>
<td>0.01 Ω</td>
<td>± 0.01 % FS</td>
<td>Excitation current 0.85 mA</td>
</tr>
<tr>
<td></td>
<td>400 to 2500 Ω</td>
<td>0.01 Ω</td>
<td>± 0.03 % FS</td>
<td>auto-ranging</td>
</tr>
<tr>
<td><b>frequency<sup>*</sup></b></td>
<td>0 to 600 Hz</td>
<td>0.01 Hz</td>
<td>± 0.04 Hz</td>
<td>R<sub>input</sub> &gt; 50KΩ</td>
</tr>
<tr>
<td></td>
<td>600 to 1300 Hz</td>
<td>0.1 Hz</td>
<td>± 0.2 Hz</td>
<td>Voltage DC<sub>max</sub> = 30 V</td>
</tr>
<tr>
<td></td>
<td valign="top">1300 to 5000 Hz</td>
<td valign="top">1 Hz</td>
<td valign="top">± 2 Hz</td>
<td>AC Signal from 0.3 to 30 V<br />
auto-ranging</td>
</tr>
<tr>
<td valign="top"><b>counter<sup>*</sup></b></td>
<td valign="top">0 to 10<sup>8</sup> -1 count</td>
<td valign="top">1 count</td>
<td valign="top"></td>
<td valign="top">The same remark as frequency Pulses Frequency &lt; 3000 Hz</td>
</tr>
<tr>
<td><b>Pt-100</b></td>
<td>-200 to 850 °C / -328 to 1562 °F</td>
<td>0.01 °C / 0.01 °F</td>
<td>± 0.1 °C / ± 0.2 °F</td>
<td>IEC-60751</td>
</tr>
<tr>
<td><b>Pt-1000</b></td>
<td>-200 to 400 °C / -328 to 752 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.1 °C / ± 0.2 °F</td>
<td>IEC-60751</td>
</tr>
<tr>
<td><b>Cu-10</b></td>
<td>-200 to 260 °C / -328 to 500 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 2.0 °C / ± 4.0 °F</td>
<td>Minco 16-9</td>
</tr>
<tr>
<td><b>Ni-100</b></td>
<td>-60 to 250 °C / -76 to 482 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.2 °C / ± 0.4 °F</td>
<td>DIN-43760</td>
</tr>
<tr>
<td><b>probe<sup>**</sup></b></td>
<td>-200 to 850 °C / -328 to 1562 °F</td>
<td>0.01 °C / 0.01 °F</td>
<td>± 0.1 °C / ± 0.2 °F</td>
<td>IEC-60751</td>
</tr>
<tr>
<td><b>TC-J</b></td>
<td>-210 to 1200 °C / -346 to 2192 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.2 °C / ± 0.4 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td><b>TC-K</b></td>
<td>-270 to -150 °C / -454 to -238 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.5 °C / ± 1.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>-150 to 1370 °C / -238 to 2498 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.2 °C / ± 0.4 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-T</b></td>
<td>-260 to -200 °C / -436 to -328 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.6 °C / ± 1.2 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>-200 to -75 °C / -328 to -103 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.4 °C / ± 0.8 °F</td>
<td></td>
</tr>
<tr>
<td></td>
<td>-75 to 400 °C / -103 to 752 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.2 °C / ± 0.4 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-B</b></td>
<td>50 to 250 °C / 122 to 482 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 2.5 °C / ± 5.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>250 to 500 °C / 482 to 932 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.5 °C / ± 3.0 °F</td>
<td></td>
</tr>
<tr>
<td></td>
<td>500 to 1200 °C / 932 to 2192 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.0 °C / ± 2.0 °F</td>
<td></td>
</tr>
<tr>
<td></td>
<td>1200 to 1820 °C / 2192 to 3308 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.7 °C / ± 1.4 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-R</b></td>
<td>-50 to 300 °C / -58 to 572 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.0 °C / ± 2.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>300 to 1760 °C / 572 to 3200 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.7 °C / ± 1.4 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-S</b></td>
<td>-50 to 300 °C / -58 to 572 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.0 °C / ± 2.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>300 to 1760 °C / 572 to 3200 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.7 °C / ± 1.4 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-E</b></td>
<td>-270 to -150 °C / -454 to -238 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.3 °C / ± 0.6 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>-150 to 1000 °C / -238 to 1832 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.1 °C / ± 0.2 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-N</b></td>
<td>-260 to -200 °C / -436 to -328 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.0 °C / ± 2.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>-200 to -20 °C / -328 to -4 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.4 °C / ± 0.8 °F</td>
<td></td>
</tr>
<tr>
<td></td>
<td>-20 to 1300 °C / -4 to 2372 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.2 °C / ± 0.4 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-L</b></td>
<td>-200 to 900 °C / -328 to 1652 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.2 °C / ± 0.4 °F</td>
<td>DIN-43710</td>
</tr>
<tr>
<td><b>TC-C</b></td>
<td>0 to 1500 °C / 32 to 2732 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.5 °C / ± 1.0 °F</td>
<td>W5Re / W26Re</td>
</tr>
<tr>
<td></td>
<td>1500 to 2320 °C / 2732 to 4208 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.7 °C / ± 1.4 °F</td>
<td></td>
</tr>
<tr>
<td colspan="6">(*) Accuracy valid since the frequency output is not configured.<br />
(**) The Probe is a separate input used as reference thermometer. The related accuracy is relative only to the MCS-XV.<br />
(***) FS = Full Scale.</td>
</tr>
</tbody>
</table>
<table border="0" cellspacing="0" cellpadding="0">
<colgroup>
<col width="5%" />
<col width="15%" />
<col width="25%" />
<col width="17%" />
<col width="17%" />
<col width="21%" /></colgroup>
<tbody>
<tr>
<td></td>
<td colspan="6"><b>Specifications &#8211; Outputs</b></td>
</tr>
<tr>
<th rowspan="35"><img decoding="async" src="https://www.mcsxv.com/images/saidas_en.png" width="25px" border="0" /></th>
<td><b>milivolt</b></td>
<td>-10 to 110 mV</td>
<td>0.001 mV</td>
<td>± 0.02 % FS <sup>***</sup></td>
<td>R<sub>out</sub> &lt; 0.3 Ω</td>
</tr>
<tr>
<td><b>volt</b></td>
<td>-0.5 to 12 V</td>
<td>0.0001 V</td>
<td>± 0.02 % FS</td>
<td>R<sub>out</sub> &lt; 0.3 Ω</td>
</tr>
<tr>
<td><b>mA</b></td>
<td>0 to 24 mA</td>
<td>0.0001 mA</td>
<td>± 0.02 % FS</td>
<td>R<sub>max</sub> = 700 Ω</td>
</tr>
<tr>
<td><b>2-wire transmitter (XTR)</b></td>
<td>4 to 24 mA</td>
<td>0.0001 mA</td>
<td>± 0.02 % FS</td>
<td>V<sub>max</sub> = 60 V</td>
</tr>
<tr>
<td valign="top"><b>resistance</b></td>
<td valign="top">0 to 400 Ω</td>
<td valign="top">0.01 Ω</td>
<td valign="top">± 0.02 % FS</td>
<td valign="top">For external excitation current<br />
of 1.0 mA</td>
</tr>
<tr>
<td></td>
<td>0 to 2500 Ω</td>
<td>0.1 Ω</td>
<td>± 0.03 % FS</td>
<td></td>
</tr>
<tr>
<td><b>frequency</b></td>
<td>0 to 100 Hz</td>
<td>0.01 Hz</td>
<td>± 0.02 Hz</td>
<td>Peak value:</td>
</tr>
<tr>
<td></td>
<td>0 to 10000 Hz</td>
<td>1 Hz</td>
<td>± 2 Hz</td>
<td>22 V / 25 mA max.</td>
</tr>
<tr>
<td valign="top"><b>pulse</b></td>
<td valign="top">0 to 10<sup>8</sup> &#8211; 1 pulse</td>
<td valign="top">1 pulse</td>
<td valign="top"></td>
<td valign="top">Peak value:<br />
22 V / 25 mA max.<br />
Pulses frequency up to 10000 Hz</td>
</tr>
<tr>
<td><b>Pt-100</b></td>
<td>-200 to 850 °C / -328 to 1562 °F</td>
<td>0.01 °C / 0.01 °F</td>
<td>± 0.2 °C / ± 0.4 °F</td>
<td>IEC-60751</td>
</tr>
<tr>
<td><b>Pt-1000</b></td>
<td>-200 to 400 °C / -328 to 752 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.1 °C / ± 0.2 °F</td>
<td>IEC-60751</td>
</tr>
<tr>
<td><b>Cu-10</b></td>
<td>-200 to 260 °C / -328 to 500 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 2.0 °C / ± 4.0 °F</td>
<td>Minco 16-9</td>
</tr>
<tr>
<td><b>Ni-100</b></td>
<td>-60 to 250 °C / -76 to 482 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.2 °C / ± 0.4 °F</td>
<td>DIN-43760</td>
</tr>
<tr>
<td><b>TC-J</b></td>
<td>-210 to 1200 °C / -346 to 2192 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.4 °C / ± 0.8 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td><b>TC-K</b></td>
<td>-270 to -150 °C / -454 to -238 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.0 °C / ± 2.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>-150 to 1370 °C / -238 to 2498 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.4 °C / ± 0.8 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-T</b></td>
<td>-260 to -200 °C / -436 to -328 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.2 °C / ± 2.4 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>-200 to -75 °C / -328 to -103 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.8 °C / ± 1.6 °F</td>
<td></td>
</tr>
<tr>
<td></td>
<td>-75 to 400 °C / -103 to 752 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.4 °C / ± 0.8 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-B</b></td>
<td>50 to 250 °C / 122 to 482 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 5.0 °C / ± 10.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>250 to 500 °C / 482 to 932 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 3.0 °C / ± 6.0 °F</td>
<td></td>
</tr>
<tr>
<td></td>
<td>500 to 1200 °C / 932 to 2192 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 2.0 °C / ± 4.0 °F</td>
<td></td>
</tr>
<tr>
<td></td>
<td>1200 to 1820 °C / 2192 to 3308 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.4 °C / ± 2.8 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-R</b></td>
<td>-50 to 300 °C / -58 to 572 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 2.0 °C / ± 4.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>300 to 1760 °C / 572 to 3200 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.4 °C / ± 2.8 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-S</b></td>
<td>-50 to 300 °C / -58 to 572 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 2.0 °C / ± 4.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>300 to 1760 °C / 572 to 3200 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.4 °C / ± 2.8 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-E</b></td>
<td>-270 to -150 °C / -454 to -238 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.6 °C / ± 1.2 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>-150 to 1000 °C / -238 to 1832 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.2 °C / ± 0.4 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-N</b></td>
<td>-260 to -200 °C / -436 to -328 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 2.0 °C / ± 4.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>-200 to -20 °C / -328 to -4 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.8 °C / ± 1.6 °F</td>
<td></td>
</tr>
<tr>
<td></td>
<td>-20 to 1300 °C / -4 to 2372 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.4 °C / ± 0.8 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-L</b></td>
<td>-200 to 900 °C / -328 to 1652 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.4 °C / ± 0.8 °F</td>
<td>DIN-43710</td>
</tr>
<tr>
<td><b>TC-C</b></td>
<td>0 to 1500 °C / 32 to 2732 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.5 °C / ± 1.0 °F</td>
<td>W5Re / W26Re</td>
</tr>
<tr>
<td></td>
<td>1500 to 2320 °C / 2732 to 4208 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.7 °C / ± 1.4 °F</td>
<td></td>
</tr>
<tr>
<td colspan="6">The values of accuracy cover one year period and for a temperature range between 20 and 26 °C. Outside this range, the thermal stability is 0.001% FS / °C with reference<br />
to 23 °C. Thermocouple with internal cold junction compensation, one must consider the error of this cold junction compensation of up to ± 0.2 °C or ± 0.4 °F.</td>
</tr>
</tbody>
</table>
<table border="0" cellspacing="0" cellpadding="0">
<colgroup>
<col width="5%" />
<col width="15%" />
<col width="25%" />
<col width="17%" />
<col width="17%" />
<col width="21%" /></colgroup>
<tbody>
<tr>
<td></td>
<td colspan="6"><b>Specifications &#8211; Pressure</b></td>
</tr>
<tr>
<th rowspan="13"><img decoding="async" src="https://www.mcsxv.com/images/pressao_en.png" width="22" border="0" /></th>
<td><b>(0)</b></td>
<td>0 &#8211; 250 mmH20</td>
<td>0,001</td>
<td>± 0,05 % FS</td>
<td rowspan="3">Gage pressure.<br />
Used with air or inert gases.</td>
</tr>
<tr>
<td><b>(1)</b></td>
<td>0 &#8211; 1 psi</td>
<td>0,0001</td>
<td>± 0,05 % FS</td>
</tr>
<tr>
<td><b>(2)</b></td>
<td>0 &#8211; 5 psi</td>
<td>0,0001</td>
<td>± 0,025 % FS</td>
</tr>
<tr>
<td><b>(3)</b></td>
<td>0 &#8211; 15 psi</td>
<td>0,0001</td>
<td>± 0,025 % FS</td>
<td rowspan="10">Gage or absolute pressure.<br />
Used with fluids (gases or liquids) compatible with 316 L stainless steel.</td>
</tr>
<tr>
<td><b>(4)</b></td>
<td>0 &#8211; 30 psi</td>
<td>0,0001</td>
<td>± 0,025 % FS</td>
</tr>
<tr>
<td><b>(5)</b></td>
<td>0 &#8211; 100 psi</td>
<td>0,001</td>
<td>± 0,025 % FS</td>
</tr>
<tr>
<td><b>(6)</b></td>
<td>0 &#8211; 250 psi</td>
<td>0,001</td>
<td>± 0,025 % FS</td>
</tr>
<tr>
<td><b>(7)</b></td>
<td>0 &#8211; 500 psi</td>
<td>0,01</td>
<td>± 0,025 % FS</td>
</tr>
<tr>
<td><b>(8)</b></td>
<td>0 &#8211; 1000 psi</td>
<td>0,01</td>
<td>± 0,025 % FS</td>
</tr>
<tr>
<td><b>(9)</b></td>
<td>0 &#8211; 3000 psi</td>
<td>0,01</td>
<td>± 0,025 % FS</td>
<td></td>
</tr>
<tr>
<td><b>(10)</b></td>
<td>0 &#8211; 5000 psi</td>
<td>0,1</td>
<td>± 0,025 % FS</td>
</tr>
<tr>
<td><b>(11)</b></td>
<td>0 &#8211; 10000 psi</td>
<td>0,1</td>
<td>± 0,05 % FS</td>
</tr>
<tr>
<td><b>(12)</b></td>
<td>Others on request</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="6"></td>
</tr>
</tbody>
</table>
</div>
<div></div>
<p>The post <a href="https://rapid-tech.com.au/presys-mcs-xv-universal-multifunction-process-calibrator/">PRESYS MCS-XV Universal Multifunction Process Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
