<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Probes &amp; Accessories Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/probes-accessories/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/probes-accessories/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Mon, 23 Sep 2024 05:33:16 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.7</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>Probes &amp; Accessories Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/probes-accessories/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Fluke 80TK Module Thermocouple</title>
		<link>https://rapid-tech.com.au/fluke-80tk-module-thermocouple/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Wed, 08 Jul 2020 00:56:25 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/fluke/index.php/product/fluke-80tk-module-thermocouple/</guid>

					<description><![CDATA[<p><a href="https://mymeter.com.au/wp-content/uploads/2020/05/Fluke-Logo.png"><img class="alignnone size-full wp-image-5177" src="https://mymeter.com.au/wp-content/uploads/2020/05/Fluke-Logo.png" alt="" width="105" height="36" /></a></p>
<p>The Fluke 80TK thermocouple module is designed for use with type-K thermocouples in low voltage applications (below 24V AC, 60V DC).</p>
<p>The Fluke 80TK also converts a digital multimeter to a digital thermometer.</p>
<p>The Fluke 80TK thermocouple module's measurement range is from -50° to 1000° (probe dependent).</p>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/fluke-80tk-module-thermocouple/">Fluke 80TK Module Thermocouple</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Fluke 80TK is a Fast, High Accuracy Temperature Measurement Compatible with any DMM having 10MΩ or greater input impedance and a mV dc scale.</p>
<p>The Fluke 80TK Thermocouple Converts any Digital Multimeter having 10MΩ or greater input impedance and a mV dc scale to a digital thermometer:</p>
<ul>
<li>For use with type-K thermocouples in low voltage applications(below 24 V AC, 60 V DC)</li>
<li>Measurement range:-50 to 1000°C (probe dependent)</li>
<li>One year warranty</li>
</ul>
<table class="spectable" width="95%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellcategory" colspan="2"><strong>Specifications</strong></td>
</tr>
<tr>
<td class="speccelltitle" width="150"><strong>Measurement Range</strong></td>
<td class="speccelldata">50ºC to 1000ºC , depending on thermocouple probe used.</td>
</tr>
<tr>
<td class="speccelltitle" width="150">Accuracy</td>
<td class="speccelldata"><strong>-50ºC to -20ºC:</strong> 2.5% ± 2ºC<br />
<strong>-20ºC to 350ºC:</strong> 0.5% ± 2ºC<strong>&#8211;</strong><br />
<strong>350ºC to 500ºC:</strong> 1.75% ± 2ºC<br />
<strong>500ºC to 1000ºC:</strong> 2% ± 2ºC</td>