<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Presys Instruments Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/presys-instruments/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/presys-instruments/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Mon, 29 Dec 2025 11:26:15 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.7</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>Presys Instruments Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/presys-instruments/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>&#8221; &#8211; Portable, Intrinsically Safe, with High-Visibility Touchscreen Display and Comprehensive DD Library</title>
		<link>https://rapid-tech.com.au/presys-fcy-15-is-full-hart-communicator-portable-intrinsically-safe-with-high-visibility-touchscreen-display-and-comprehensive-dd-library/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Fri, 20 Oct 2023 04:19:29 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=27095</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg"><img class="alignnone size-full wp-image-5972" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg" alt="" width="265" height="64" /></a></p>
<p><a target="_blank" href="https://mymeter.com.au/product/presys-fcy-15-is-full-hart-communicator-portable-intrinsically-safe-with-high-visibility-touchscreen-display-and-comprehensive-dd-librarypresys-mcs-xv-is-intrinsically-safe-multifunction-pro" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Experience the cutting-edge <b><strong class="font-bold">Presys FCY-15-IS Full HART® Communicator,</strong></b> a supremely portable and intrinsically safe device designed for your field control needs. Independent of manufacturer or model, it provides full access to your instrument's parameters tree via HART® protocol. Its high visibility 5.7-inch touchscreen display ensures easy operation. With the latest DD’s Library, and the ability to include unregistered DD's, stay ahead of the curve. The device also boasts a convenient 15V power supply for two-wire transmitters and an input for measuring current. Its rechargeable batteries promise up to 8 hours of continuous field use. Safeguard your HART® instrument settings with the option to upload, save, and download. Upgrade your field control communication experience today!</p>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png"><img class="alignnone size-full wp-image-19718" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" /></a>  <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2023/02/PRESYS-MCS-XV-IS-Datasheet.pdf" rel="noopener"></a> <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2023/10/EF0898-00FCY-15-IS_en.pdf" rel="noopener">Presys FCY-15 HART Communicator Datasheet</a></h4>
<p>The post <a href="https://rapid-tech.com.au/presys-fcy-15-is-full-hart-communicator-portable-intrinsically-safe-with-high-visibility-touchscreen-display-and-comprehensive-dd-library/">&#8221; &#8211; Portable, Intrinsically Safe, with High-Visibility Touchscreen Display and Comprehensive DD Library</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Introducing the <b><strong class="font-bold">Presys FCY-15-IS Full HART® Communicator</strong></b> &#8211; an intrinsically safe, portable device engineered to fine-tune your field control needs. This tool isn&#8217;t confined by manufacturer or model, offering full access to the entire instrument&#8217;s parameters tree via the HART® protocol.</p>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Experience ease of operation with its 5.7&#8243; high visibility colour display, fully touchscreen with a friendly interface. The device comes with a two-level HART® configuration interface—Calibration HART® and Full HART®—catering to all your configuration needs. The latest Device Descriptions (DD’s) Library, registered in the FieldComm Group, and the capacity to include unregistered DD&#8217;s, keeps you ahead in the game.</p>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">The Presys FCY-15-IS offers a handy 15V power supply for two-wire transmitters with an internal resistor or a selectable 250 Ω. Furthermore, its built-in input for measuring current allows for convenient instrument trim and loop testing.</p>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Never compromise on your work, thanks to its rechargeable Ni-MH batteries, ensuring continuous use for up to 8 hours in the field. The device also provides the ability to upload, save, and download HART® instrument settings, offering a secure backup option on your computer.</p>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">The <b><strong class="font-bold">Presys FCY-15-IS</strong></b> offers a more cost-effective solution compared to the <a target="_blank" href="https://rapid-tech.com.au/emerson-ams-trex-device-communicator/" rel="noopener"><b><strong class="font-bold">Emerson TREX,</strong></b></a> providing the same functionality at a better value.</p>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">The device, with its inclusive DD Library, is both a cost-effective and powerful alternative. Step into the future of field control communication with Presys.</p>
<p>The post <a href="https://rapid-tech.com.au/presys-fcy-15-is-full-hart-communicator-portable-intrinsically-safe-with-high-visibility-touchscreen-display-and-comprehensive-dd-library/">&#8221; &#8211; Portable, Intrinsically Safe, with High-Visibility Touchscreen Display and Comprehensive DD Library</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PRESYS TE-300PLL Dry Well Calibrator &#124;- Liquid Bath combination</title>
		<link>https://rapid-tech.com.au/presys-te-300pll-dry-well-calibrator-liquid-bath-combination/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Thu, 02 Mar 2023 23:16:48 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=26204</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg"><img class="alignnone size-full wp-image-5972" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg" alt="" width="265" height="64" /></a></p>
<p>The PRESYS TE-300PLL Dry Well Calibrator and Liquid Bath combination is the premier choice for precision calibration tasks. Equipped with a technically advanced design that combines high performance parameters, such as ± 0.01 ºC of stability, with unbeatable portability and ease of use, the device will provide maintenance personnel an unprecedented degree of accuracy and reliability in all their calibration needs. The calibrator features an input for thermocouples, resistance thermometers and thermoswitches as well as a 24 Vdc power supply, mA input for 2-wire transmitters and extra-large calibration volume (59 mm diameter x 200 mm height). It can generate temperatures from ambient to 300ºC with 0.01 ºC resolution! Automation capabilities ensure easy setup even without the need for a computer - making it perfect for spontaneous field repairs or scheduled laboratory calibrations. With its foresighted engineering, the PRESYS is sure to become your go-to tool in maintenance!</p>
<h4><img class="alignnone size-full wp-image-19718" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" /> <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2023/03/PRESYS-TE-300PLL-Dry-Well-Calibrator-Datasheet.pdf" rel="noopener">PRESYS TE-300PLL Dry Well Calibrator Datasheet</a></h4>
<p>The post <a href="https://rapid-tech.com.au/presys-te-300pll-dry-well-calibrator-liquid-bath-combination/">PRESYS TE-300PLL Dry Well Calibrator |- Liquid Bath combination</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The PRESYS TE-300PLL Dry Well Calibrator and Liquid Bath combination is a high performance, portable solution for calibrating a wide range of instruments. This powerful device can generate temperatures from ambient to 300ºC with an extra large calibration volume (59 mm diameter x 200 mm height). It features high stability, uniformity and accuracy with 0.01 ºC resolution and better than ± 0.01 ºC stability. The calibrator has inputs for thermocouples, resistance thermometers and thermoswitches as well as an internal regulated 24 Vdc power supply and mA input for 2-wire transmitters. Automated calibration can easily be achieved even without the use of a computer &#8211; perfect for on-the-spot adjustments or preplanned tasks in laboratory environments! Additionally, it offers documenting capabilities such as connection with computers using ISOPLAN calibration software plus Bluetooth remote control through Android devices making this product ideal for quick, reliable results wherever you are.</p>
<h4>Key Features</h4>
<ul>
<li>PRESYS TE-300PLL Dry Well Calibrator / Liquid Bath combination</li>
<li>Portable Stirred Liquid Bath and Dry Block Calibrator with Large Calibration Volume</li>
<li>TE-300PLL generates temperatures from ambient temperature to 300 ºC.</li>
<li>Extra large calibration volume: 59 mm diameter x 200 mm height</li>
<li>High Stability, Uniformity and Accuracy.</li>
<li>Resolution of 0.01 °C.</li>
<li>Stability better than ± 0.01 °C.</li>
<li>Have input for thermocouples, resistance thermometers and thermoswitches.</li>
<li>Internal regulated 24 Vdc power supply and mA input for 2-wire transmitters.</li>
<li>Completely automatic calibration with or without the use of a computer.</li>
<li>Documenting capabilities: connection with computer and ® ISOPLAN calibration software.</li>
<li>Remote Control via Bluetooth and Android application.</li>
</ul>
<p>The post <a href="https://rapid-tech.com.au/presys-te-300pll-dry-well-calibrator-liquid-bath-combination/">PRESYS TE-300PLL Dry Well Calibrator |- Liquid Bath combination</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Presys MCS-XV-IS  -&#124; Intrinsically Safe Multifunction Process Calibrator &#124; Ex ia IIC T4 Ga</title>
		<link>https://rapid-tech.com.au/presys-mcs-xv-is-intrinsically-safe-multifunction-process-calibrator-ex-ia-iic-t4-ga/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Wed, 08 Feb 2023 04:09:42 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=25984</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg"><img class="alignnone size-full wp-image-5972" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg" alt="" width="265" height="64" /></a></p>
<p><a target="_blank" href="https://mymeter.com.au/product/presys-mcs-xv-is-intrinsically-safe-multifunction-process-calibrator-ex-ia-iic-t4-ga" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<p>The Presys MCS-XV-IS Intrinsically Safe Multifunction Process Calibrator is a powerful, versatile tool ideal for instrumentation professionals. The exceptional performance of this high-quality calibrator empowers users with access to all types of signals, from electrical to temperature and frequency readings. It also offers outstanding pressure management capabilities with an optional barometric reference and the capacity to handle up to four pressure sensors that range from 250 mmH2O to 10,000 psi.</p>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png"><img class="alignnone size-full wp-image-19718" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" /></a>  <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2023/02/PRESYS-MCS-XV-IS-Datasheet.pdf" rel="noopener">PRESYS MCS-XV-IS Datasheet</a>     <a href="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png"><img class="alignnone size-full wp-image-19718" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" /></a> <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2023/02/Presys-MCS-XV-IS-User-Manual-.pdf" rel="noopener">Presys MCS-XV-IS User Manual</a></h4>
<p>The post <a href="https://rapid-tech.com.au/presys-mcs-xv-is-intrinsically-safe-multifunction-process-calibrator-ex-ia-iic-t4-ga/">Presys MCS-XV-IS  -| Intrinsically Safe Multifunction Process Calibrator | Ex ia IIC T4 Ga</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Presys MCS-XV-IS is an intrinsically safe multifunction process calibrator that operates a variety of instrumentation signals: electrical, temperature, frequency, and pressure up to four pressure sensors from 250 mmH2O to 10.000 psi.</p>
<p class="">It features a touchscreen display for easy-to-read data with the ability to show two variables simultaneously. The intuitive menu navigation helps users identify information for any operational mode and provides full Hart configurator (optional) capability for configuring all available HART® devices using the DD library from FieldComm Group.</p>
<p>Additionally, this reliable device offers 15 Vdc power supply for 2 wire transmitters as well as 250W internal resistor configuration capabilities, along with data logger functions for data acquisition and graphical visualization plus Wi-Fi USB connection Host / Device options and automated calibration report generation on direct connected printers or a PDF file via pen drive connections.</p>
<p>With its top-notch components and impeccable manufacturing processes, this invaluable Presys MCS-XV-IS offers the ultimate in durability that is sure to last for years &#8211; all while graciously saving you costs.</p>
<p>The post <a href="https://rapid-tech.com.au/presys-mcs-xv-is-intrinsically-safe-multifunction-process-calibrator-ex-ia-iic-t4-ga/">Presys MCS-XV-IS  -| Intrinsically Safe Multifunction Process Calibrator | Ex ia IIC T4 Ga</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Pressure Calibrator &#124; PC-507-IS</title>
		<link>https://rapid-tech.com.au/pressure-calibrator-pc-507-is/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Thu, 29 Jul 2021 02:10:53 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=19019</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-5972" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg" alt="" width="265" height="64" /></p>
<p>The Pressure Calibrator PC-507-IS is an intrinsically safe calibrator suitable for use in hazardous (high explosive) areas like oil and gas. Can be operated in Group IIC Zone 0 which is the most demanding about the need for protection against electric sparks, it is the group of hydrogen and acetylene.</p>
<p><img class="size-full wp-image-17809 alignnone" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-Download-e1620015214396.png" alt="PDF Download icon" width="51" height="60" /> <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2021/07/encomenda_2_155.pdf" rel="noopener">PC-507-IS -Datasheet</a></p>
<p>The post <a href="https://rapid-tech.com.au/pressure-calibrator-pc-507-is/">Pressure Calibrator | PC-507-IS</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The front layout is different from the PC-507, in order to characterize unequivocally the Intrinsically Safe version. RS-232/485 serial communication port there for to connect to the computer. When used together with ISOPLAN® calibration software, it takes advantage of the documenting calibration concept which automatizes the calibration process, allowing data storage and sharing between calibrator and computer, improving efficiency in handling information, preparing report, issuing certificates, storage and registration of process instruments and sensors for an overall coverage of the quality procedure requirements, specially those related to ISO 9000.</p>
<p><strong>Key Features:</strong></p>
<ul id="produto">
<li>Up to four pressure sensors from 10&#8243; H₂O to 10,000 psi gauge or absolute pressure, including vacuum.</li>
<li>Measures differential pressure between any pair of sensors.</li>
<li>Measures and generates mA and volts.</li>
<li>Includes input for optional temperature probe.</li>
<li>Accuracy of 0.025% of full scale.</li>
<li>Pressure Switch test.</li>
<li>Portable, compact, powered by rechargeable batteries.</li>
<li>Power supply for 2-wire transmitters.</li>
<li>Serial communication.</li>
<li>PC-507-IS is an intrinsically safe pressure calibrator Ex ia IIC T4 Ga certified for usage in Ex-hazardous areas Zones 0, 1, and 2.</li>
</ul>
<p>The post <a href="https://rapid-tech.com.au/pressure-calibrator-pc-507-is/">Pressure Calibrator | PC-507-IS</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>High Temperature Furnace for your thermocouple calibrations &#124; TA-1200PLAB</title>
		<link>https://rapid-tech.com.au/high-temperature-furnace-for-your-thermocouple-calibrations-ta-1200plab/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Mon, 19 Jul 2021 03:00:14 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=18909</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg"><img class="alignnone size-full wp-image-5972" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg" alt="" width="265" height="64" /></a></p>
<p>The TA-1200PLAB is an extensive immersion high temperature furnace, offering the best-in-class accuracy, stability, and homogeneity, that will reduce drastically the uncertainties of your thermocouples <a target="_blank" href="https://rapid-tech.com.au/?product_cat=&#38;s=Dry+Block+Calibrators&#38;post_type=product" rel="noopener" class="guideLinr-element-highlight">dry block calibrators</a>.</p>
<h4><strong>Features:</strong></h4>
<ul>
<li>Best-in-class temperature stability and uniformity</li>
<li>Use of Type R noble metal thermocouples for uniformity control</li>
<li>3 zones control</li>
<li>Improve uncertainty of thermocouples calibrations</li>
</ul>
<p><img class="alignnone size-full wp-image-17809" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-Download-e1620015214396.png" alt="PDF Download icon" width="51" height="60" /> <a href="https://rapid-tech.com.au/wp-content/uploads/2021/07/TA-1200pLab-Datasheet.pdf">TA-1200pLab Datasheet</a></p>
<p>The post <a href="https://rapid-tech.com.au/high-temperature-furnace-for-your-thermocouple-calibrations-ta-1200plab/">High Temperature Furnace for your thermocouple calibrations | TA-1200PLAB</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>TA-1200PLAB <a target="_blank" href="https://rapid-tech.com.au/dry-blockwell-calibrators/" rel="noopener">dry well Calibrator</a> produces temperature values in the insert or block from 50 to 1200 °C. It has two inputs for mV and for various thermocouples types, including Au-Pt, with deviation function configurable. It is available in two mounting versions: horizontal and vertical.</p>
<p>Its high accuracy, uniformity and stability is due to the fact that TA-1200PLAB high temperature calibrator has three control zones, allowing better distribution of temperature throughout the block and ensuring a better radial and axial uniformity through the extension of the 100 mm of measurement zone.</p>
<p>TA-1200PLAB incorporates concepts of automatic calibration with calibration management softwares, especially with the Isoplan® Software, such as issuing reports and certificates, task management, calibration data organization and archiving etc.</p>
<p>The post <a href="https://rapid-tech.com.au/high-temperature-furnace-for-your-thermocouple-calibrations-ta-1200plab/">High Temperature Furnace for your thermocouple calibrations | TA-1200PLAB</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PRESYS T-650PH Multifunction Temperature Calibrator</title>
		<link>https://rapid-tech.com.au/drywell-temperature-calibrator/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Fri, 10 Jul 2020 08:05:30 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=15958</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg"><img class="alignnone size-full wp-image-5972" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg" alt="" width="265" height="64" /></a></p>
<p>The PRESYS T-650PH dry block calibrator controls temperature of an insert in order to calibrate thermocouples, thermoresistances, glass thermometers, thermoswitches etc.</p>
<p>As well as providing high accuracy temperature values, it also allows the measurement of signals generated by thermo-elements which are being calibrated.</p>
<p><strong>PRESYS T-650PH Features:</strong></p>
<ul id="produto">
<li>Generates temperatures from ambient to 650 °C.</li>
<li>Dry Block and <strong>Black Body</strong> Inserts.</li>
<li>Horizontal mounting, facilitates infrared thermometer calibration.</li>
</ul>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/07/PRESYS-T-650PH.pdf" rel="noopener noreferrer">PRESYS T-650PH Datasheet</a></span></h3>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/07/Presys-T-650-User-Manual.pdf" rel="noopener noreferrer">Presys T-650 User Manual</a></span></h3>
<p>The post <a href="https://rapid-tech.com.au/drywell-temperature-calibrator/">PRESYS T-650PH Multifunction Temperature Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The PRESYS T-650PH dry block calibrator controls temperature of an insert in order to calibrate thermocouples, thermoresistances, glass thermometers, thermoswitches etc.</p>
<p>As well as providing high accuracy temperature values, it also allows the measurement of signals generated by thermo-elements which are being calibrated. This is possible due to an embedded calibrator specific for these types of signal, including 4-20 mA. Thus, they incorporate the functions of dry block, standard thermometer and calibrator for RTD, TC and mA.</p>
<ul>
<li>T-650PH calibrator model generates temperatures from room temperature to 650ºC (1202ºF).</li>
<li>Present input for thermocouples, RTDs, thermoswitches. Besides generating temperature, they measure the signal from the sensor being calibrated.</li>
<li>Dry block and black body inserts.</li>
<li>Allows the control of the dry block temperature by using an external probe (optional). The temperature calculation uses Callendar-Van Dusen coefficients.</li>
<li>Make no use of external standard thermometer.</li>
<li>Carries out completely automatic calibrations with or without the use of a computer.</li>
<li>Accuracy to 0.1ºC ± 0.1% of reading, stability of 0.05ºC and resolution of 0.01ºC.</li>
<li>Documenting capabilities: communication with computer and ISOPLAN Calibration Software.</li>
<li>Portable, compact, provide interchangeable inserts and carrying case.</li>
</ul>
<p>It presents a wide variety of programming resources, allowing the performance of automatic calibrations of thermocouples, RTDs, thermoswitches. In this case, the sensor is placed in the insert and their electrical terminals are connected to the embedded calibrator. The operator defines the calibration points and the number of repetitions, then the process is started and all the sequence is automatically accomplished.</p>
<p>Another way of performing automatic documented calibrations is by means of ISOPLAN Calibration Software for PC/WindowsTM, which uses RS-232 or RS-485 serial communication to connect the computer to the dry block. With ISOPLAN it is possible to register sensors and instruments of a factory, generate work orders, create and print calibrations certificates and reports, that is, it brings all advantages of computer data management to the calibration environment.</p>
<p>T<strong>-650PH has also many other features:</strong></p>
<p>·   The electric signal calibrator is independent from the dry block function.<br />
·   Internal buzzer beeps when the temperature reaches the desired value.<br />
·   Keypad that eases the operation and configuration of the calibrator.<br />
·   Graphic Fluorescent vacuum display to present big-size digit numbers.<br />
·   Thermo-element reading scaled to ITS-90 or IPTS-68.<br />
·   Internal regulated 24 Vdc power supply for 2-wire transmitters.<br />
·   Internal  rechargeable  battery  and  battery  charger  included  in  the  electric  signal calibrator.<br />
·   Independent circuitry for over-temperature protection and safety.<br />
·   Insert to choose, carrying case, strap and test leads included.</p>
<h4>Basic Specifications:</h4>
<table style="height: 431px;" width="542">
<tbody>
<tr>
<td width="172">Operating Range</td>
<td width="322">From room temperature to 650 °C (1202 °F)</td>
</tr>
<tr>
<td width="172">Power Supply</td>
<td width="322">110Vac or 220Vac 50/60Hz, according to order code.</td>
</tr>
<tr>
<td width="172">Well Depth</td>
<td width="322">124 mm</td>
</tr>
<tr>
<td width="172">Resolution</td>
<td width="322">0.01 °C (0.01 °F)</td>
</tr>
<tr>
<td width="172">Accuracy</p>
<p>Internal reference<br />
with external probe<br />
with external thermometer</td>
<td width="322">&nbsp;</p>
<p>± 0.1 °C ± 0.1 % of reading<br />
± 0.10 °C<br />
± 0.05 °C</td>
</tr>
<tr>
<td width="172">Stability<br />
(after 10 minutes)</td>
<td width="322">±0.05 °C</td>
</tr>
<tr>
<td width="172">Power Consumption</td>
<td width="322">1000 W</td>
</tr>
<tr>
<td width="172">Heating Rate</td>
<td width="322">20 minutes (50 °C to 650 °C)</td>
</tr>
<tr>
<td width="172">Cooling Rate</td>
<td width="322">21 minutes (650 °C to 200 °C)</td>
</tr>
<tr>
<td width="172">Dimensions (H,W,D)</td>
<td width="322">215 x 390 x 310 mm</td>
</tr>
<tr>
<td width="172">Weight</td>
<td width="322">9.0 kg</td>
</tr>
<tr>
<td width="172">Warranty</td>
<td width="322">1 year</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/drywell-temperature-calibrator/">PRESYS T-650PH Multifunction Temperature Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PRESYS TC-512 Temperature Calibrator</title>
		<link>https://rapid-tech.com.au/presys-tc-512-temperature-calibrator/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 28 Apr 2020 23:08:25 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=15018</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg"><img class="alignnone size-full wp-image-5972" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg" alt="" width="265" height="64" /></a></p>
<p>The PRESYS TC-512 Temperature Calibrator enables measurement and generation of signals used in instrumentation and Process Control.</p>
<p>It is a high-accuracy instrument, having high stability features in temperature changes and long-term aging conditions.</p>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/04/Presys-TC-512-Datasheet.pdf" rel="noopener noreferrer">Presys TC-512 Datasheet</a></span></h3>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/04/Presys-TC-512-User-Manual.pdf" rel="noopener noreferrer">Presys TC-512 User Manual</a></span></h3>
<p>The post <a href="https://rapid-tech.com.au/presys-tc-512-temperature-calibrator/">PRESYS TC-512 Temperature Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The PRESYS TC-512 Temperature Calibrator enables measurement and generation of signals used in instrumentation and Process Control. It is a high-accuracy instrument, having high stability features in temperature changes and long-term aging conditions.</p>
<p>The TC-512 Probe input calculates the temperature based on international standard tables, in IPTS-68 and ITS-90 scales, and also has algorithms that calculate temperatures using Callendar-Van Dusen coefficients from a calibrated sensor.</p>
<p>PRESYS TC-512 Temperature Calibrator contains useful items allowing its on field and workbench use. The TC-512 also incorporates concepts of automatic checking and calibration via computer, such as report and certificate issues, automatic work management, data archiving for an overall coverage of quality procedure requirements.</p>
<p>Additionally, various optional modules are available, intended to perform pressure and temperature measurements.</p>
<h4>PRESYS TC-512 Temperature Calibrator Features:</h4>
<ul id="produto">
<li>Measures and generates mA, mV, volts, ohms, RTD and TC.</li>
<li>Simultaneous input and output operation.</li>
<li>Isolated input and output.</li>
<li>Interface with a Windows-based Calibration Software to provide a true Computer-Aided Calibration System with documenting capability.</li>
<li>Real-time data acquisition capability when connected to a computer.</li>
<li>Callendar-Van Dunsen coeficientes for Probe input.</li>
</ul>
<p>&nbsp;</p>
<p>The post <a href="https://rapid-tech.com.au/presys-tc-512-temperature-calibrator/">PRESYS TC-512 Temperature Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PRESYS MCS-12-IS Multifunction Intrinsically Safe Process Calibrator</title>
		<link>https://rapid-tech.com.au/presys-mcs-12-is-multifunction-intrinsically-safe-process-calibrator/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 28 Apr 2020 01:13:48 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=15014</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg"><img class="alignnone size-full wp-image-5972" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg" alt="" width="265" height="64" /></a></p>
<p>The PRESYS MCS-12-IS is a documenting multifunction calibrator that enables measurement and generation of signals used in Instrumentation and Process Control.</p>
<p>It is portable, compact and ideal for field use with performance levels comparable to laboratory standards.</p>
<p>The MCS-12-IS communicates with ISOPLAN® Calibration Software in a Windows™ environment providing a true Document Assisted Calibration System.</p>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/04/Presys-MCS-12-IS-Datasheet.pdf" rel="noopener noreferrer">Presys MCS-12-IS Datasheet</a></span></h3>
<p>The post <a href="https://rapid-tech.com.au/presys-mcs-12-is-multifunction-intrinsically-safe-process-calibrator/">PRESYS MCS-12-IS Multifunction Intrinsically Safe Process Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The PRESYS MCS-12-IS Multifunction Intrinsically Safe Process Calibrator has been approved for use in hazardous areas.<br />
The MCS-12-IS is approved as intrinsically safe and can be operated in the Group IIC Zone 0, which is the most demanding regarding the need for protection against electric sparks, is the group of hydrogen and acetylene.</p>
<p>The Probe input calculates temperatures based on standard international tables on the IPTS-68 and ITS-90 scales and also has internal algorithms that calculate temperatures using Callendar-Van Dusen coefficients from a sensor calibration. It has useful items that allow it to be used in the field and on a bench.</p>
<p>The calibrator also incorporates automatic computer calibration concepts, such as report and certificate issuance, automatic task management, organization and data archiving to meet the requirements of quality procedures.</p>
<h3>PRESYS MCS-12-IS Features</h3>
<ul>
<li>Intrinsically safe Universal Process Calibrator Certified Ex ia IIC T4 Ga for usage in Ex-hazardous areas Zones 0,1 and 2.</li>
<li>Portable, compact, powered by rechargeable batteries.</li>
<li>Measures and generates mA, mV, volts, ohms, RTD, TC and Hz.</li>
<li>Simultaneous input and output operation. 12 Vcc/ 30 mA Power supply for 2-wire transmitters. Includes input for optional temperature probe.</li>
<li>Callendar-Van Dunsen coeficientes for Probe input.</li>
</ul>
<p>&nbsp;</p>
<p>The post <a href="https://rapid-tech.com.au/presys-mcs-12-is-multifunction-intrinsically-safe-process-calibrator/">PRESYS MCS-12-IS Multifunction Intrinsically Safe Process Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Documenting Process Calibrator With Full HART Communicator &#124; PRESYS MCS-XV</title>
		<link>https://rapid-tech.com.au/presys-mcs-xv-documenting-process-calibrator/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Mon, 23 Apr 2018 18:02:08 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=7267</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg"><img class="alignnone size-full wp-image-5972" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg" alt="" width="265" height="64" /></a></p>
<h3>PRESYS MCS-XV Documenting Process Calibrator Features:</h3>
<ul id="produto">
<li>Measures and generates <strong>mA, mV, Volts, ohms, RTD, TC, and Hz</strong> with accuracy <strong>0.01%</strong> up to full scale.</li>
<li>Up to four optional Pressure modules of <strong>250 mmH<sub>2</sub>O pressure to 10,000 psi</strong>. It has the barometric reference (optional) for absolute pressure indication.</li>
<li>Hart Full Configurator (optional). Compatible with DD configuration files recorded in FieldComm Group.</li>
<li>24Vdc power supply for two-wire transmitter. internal 250 ohms resistor configurable.</li>
<li>Documentation capability. Automatic calibration tasks can be created or executed with or without the use of computers.</li>
<li>Calibration Reports issued directly to USB printer or PDF file.</li>
<li>Data logger function for data acquisition and display in graphical format.</li>
<li>Touchscreen display with high visibility friendly interface.</li>
<li>Compact, portable, powered by rechargeable batteries for field use.</li>
<li>Also available in versions <strong>Desktop (DT) and 19" Rack Mounting (RM).</strong></li>
<li>e-Connected: Ethernet, Wi-Fi (optional), Pen-drive, Hart, Profibus*, Fieldbus Foundation*, Modbus* and USB Host/Device</li>
<li>Similar to Fluke 754 Documenting Process Calibrator and Emerson TREX Communicator</li>
</ul>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2017/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-5148" src="https://rapid-tech.com.au/wp-content/uploads/2017/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="color: #0000ff;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-MCS-XV-Datasheet.pdf" rel="noopener">Presys MCS-XV Datasheet</a></span></h3>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="color: #0000ff;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-MCS-XV-User-Manual.pdf" rel="noopener">Presys MCS-XV User Manual</a></span></h3>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/presys-mcs-xv-documenting-process-calibrator/">Documenting Process Calibrator With Full HART Communicator | PRESYS MCS-XV</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The PRESYS MCS-XV Documenting Process Calibrator with HART Communicator enables measurement and generation of signals used in instrumentation and process control. It provides all the features required for easier calibration and adjustment services on process instruments. It has high levels of accuracy, including aspects relating to changes in room temperature and maintains the specifications over long periods of time. It is similar in function to the Fluke 754 Documenting Process Calibrator.</p>
<p>The PRESYS MCS-XV Documenting Process Calibrator with HART Communicator is <strong>designed for field use</strong> and includes: carrying case, holders with fastener rings or belts for a hands-free operation, 5.7” display with LED backlight for a better viewing in poor lighting conditions, rechargeable battery and large memory capacity to store the values obtained during calibrations enabling the transfer of these to the PC when needed.</p>
<p>In addition to these features the PRESYS MCS-XV with HART Communicator is available in a <strong>19&#8243; Rack Mount version</strong> (RM) or as a <strong>Desktop Instrument</strong> (DT).</p>
<p>The PRESYS MCS-XV Documenting Process Calibrator incorporates state-of-the-art concepts of automatic calibration and adjustment via computer. Instrument and computer share measurement data obtained for a more efficient handling of information such as report and certificate issues, automatic work management, data sorting and storage, for an overall coverage of quality procedure requirements, especially those related to ISO-9000.</p>
<p>The PRESYS MCS-XV has HART communication for reading and setting parameters of field devices that have this protocol and can be supplied with up to four pressure sensors. Thus, a single calibrator can have different ranges of pressure, for example vacuum, 0 to 100 psi, 0 to 1,000 psi and 0 to 3,000 psi, or any combination of available ranges.</p>
<figure id="attachment_5985" aria-describedby="caption-attachment-5985" style="width: 635px" class="wp-caption aligncenter"><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-MCSXV-Operator.jpg"><img fetchpriority="high" decoding="async" class="size-full wp-image-5985" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-MCSXV-Operator.jpg" alt="" width="635" height="364" srcset="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-MCSXV-Operator.jpg 635w, https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-MCSXV-Operator-300x172.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-MCSXV-Operator-600x344.jpg 600w" sizes="(max-width: 635px) 100vw, 635px" /></a><figcaption id="caption-attachment-5985" class="wp-caption-text">Presys MCS-XV Portable version in use.</figcaption></figure>
<h3>PRESYS MCS-XV Documenting Process Calibrator Specifications:</h3>
<div>
<table style="height: 13px;" border="0" width="998" cellspacing="0" cellpadding="5">
<thead>
<tr>
<td class="center" colspan="2">Ranges</td>
<td class="center">Resolution</td>
<td class="center">Accuracy</td>
<td class="center">Remarks</td>
</tr>
</thead>
</table>
</div>
<div>
<table border="0" cellspacing="0" cellpadding="0">
<colgroup>
<col width="5%" />
<col width="15%" />
<col width="25%" />
<col width="17%" />
<col width="17%" />
<col width="21%" /></colgroup>
<tbody>
<tr>
<td></td>
<td colspan="6"><b>Specifications &#8211; Inputs</b></td>
</tr>
<tr>
<th rowspan="38"><img decoding="async" src="https://www.mcsxv.com/images/entradas_en.png" width="25px" border="0" /></th>
<td><b>milivolt</b></td>
<td>-150 to 150 mV</td>
<td>0.001 mV</td>
<td>± 0.01 % FS <sup>***</sup></td>
<td>R<sub>input</sub> &gt; 10 MΩ</td>
</tr>
<tr>
<td></td>
<td>-500 to -150 mV</td>
<td>0.01 mV</td>
<td>± 0.02 % FS</td>
<td>auto-ranging</td>
</tr>
<tr>
<td></td>
<td>150 to 2450 mV</td>
<td>0.01 mV</td>
<td>± 0.02 % FS</td>
<td></td>
</tr>
<tr>
<td><b>volt</b></td>
<td>-10 to 45 V</td>
<td>0.0001 V</td>
<td>± 0.02 % FS</td>
<td>R<sub>input</sub> &gt; 1 MΩ</td>
</tr>
<tr>
<td><b>mA</b></td>
<td>-5 to 24.5 mA</td>
<td>0.0001 mA</td>
<td>± 0.02 % FS</td>
<td>R<sub>input</sub> &lt; 120Ω</td>
</tr>
<tr>
<td><b>resistance</b></td>
<td>0 to 400 Ω</td>
<td>0.01 Ω</td>
<td>± 0.01 % FS</td>
<td>Excitation current 0.85 mA</td>
</tr>
<tr>
<td></td>
<td>400 to 2500 Ω</td>
<td>0.01 Ω</td>
<td>± 0.03 % FS</td>
<td>auto-ranging</td>
</tr>
<tr>
<td><b>frequency<sup>*</sup></b></td>
<td>0 to 600 Hz</td>
<td>0.01 Hz</td>
<td>± 0.04 Hz</td>
<td>R<sub>input</sub> &gt; 50KΩ</td>
</tr>
<tr>
<td></td>
<td>600 to 1300 Hz</td>
<td>0.1 Hz</td>
<td>± 0.2 Hz</td>
<td>Voltage DC<sub>max</sub> = 30 V</td>
</tr>
<tr>
<td></td>
<td valign="top">1300 to 5000 Hz</td>
<td valign="top">1 Hz</td>
<td valign="top">± 2 Hz</td>
<td>AC Signal from 0.3 to 30 V<br />
auto-ranging</td>
</tr>
<tr>
<td valign="top"><b>counter<sup>*</sup></b></td>
<td valign="top">0 to 10<sup>8</sup> -1 count</td>
<td valign="top">1 count</td>
<td valign="top"></td>
<td valign="top">The same remark as frequency Pulses Frequency &lt; 3000 Hz</td>
</tr>
<tr>
<td><b>Pt-100</b></td>
<td>-200 to 850 °C / -328 to 1562 °F</td>
<td>0.01 °C / 0.01 °F</td>
<td>± 0.1 °C / ± 0.2 °F</td>
<td>IEC-60751</td>
</tr>
<tr>
<td><b>Pt-1000</b></td>
<td>-200 to 400 °C / -328 to 752 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.1 °C / ± 0.2 °F</td>
<td>IEC-60751</td>
</tr>
<tr>
<td><b>Cu-10</b></td>
<td>-200 to 260 °C / -328 to 500 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 2.0 °C / ± 4.0 °F</td>
<td>Minco 16-9</td>
</tr>
<tr>
<td><b>Ni-100</b></td>
<td>-60 to 250 °C / -76 to 482 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.2 °C / ± 0.4 °F</td>
<td>DIN-43760</td>
</tr>
<tr>
<td><b>probe<sup>**</sup></b></td>
<td>-200 to 850 °C / -328 to 1562 °F</td>
<td>0.01 °C / 0.01 °F</td>
<td>± 0.1 °C / ± 0.2 °F</td>
<td>IEC-60751</td>
</tr>
<tr>
<td><b>TC-J</b></td>
<td>-210 to 1200 °C / -346 to 2192 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.2 °C / ± 0.4 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td><b>TC-K</b></td>
<td>-270 to -150 °C / -454 to -238 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.5 °C / ± 1.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>-150 to 1370 °C / -238 to 2498 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.2 °C / ± 0.4 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-T</b></td>
<td>-260 to -200 °C / -436 to -328 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.6 °C / ± 1.2 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>-200 to -75 °C / -328 to -103 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.4 °C / ± 0.8 °F</td>
<td></td>
</tr>
<tr>
<td></td>
<td>-75 to 400 °C / -103 to 752 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.2 °C / ± 0.4 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-B</b></td>
<td>50 to 250 °C / 122 to 482 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 2.5 °C / ± 5.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>250 to 500 °C / 482 to 932 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.5 °C / ± 3.0 °F</td>
<td></td>
</tr>
<tr>
<td></td>
<td>500 to 1200 °C / 932 to 2192 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.0 °C / ± 2.0 °F</td>
<td></td>
</tr>
<tr>
<td></td>
<td>1200 to 1820 °C / 2192 to 3308 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.7 °C / ± 1.4 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-R</b></td>
<td>-50 to 300 °C / -58 to 572 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.0 °C / ± 2.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>300 to 1760 °C / 572 to 3200 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.7 °C / ± 1.4 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-S</b></td>
<td>-50 to 300 °C / -58 to 572 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.0 °C / ± 2.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>300 to 1760 °C / 572 to 3200 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.7 °C / ± 1.4 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-E</b></td>
<td>-270 to -150 °C / -454 to -238 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.3 °C / ± 0.6 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>-150 to 1000 °C / -238 to 1832 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.1 °C / ± 0.2 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-N</b></td>
<td>-260 to -200 °C / -436 to -328 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.0 °C / ± 2.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>-200 to -20 °C / -328 to -4 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.4 °C / ± 0.8 °F</td>
<td></td>
</tr>
<tr>
<td></td>
<td>-20 to 1300 °C / -4 to 2372 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.2 °C / ± 0.4 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-L</b></td>
<td>-200 to 900 °C / -328 to 1652 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.2 °C / ± 0.4 °F</td>
<td>DIN-43710</td>
</tr>
<tr>
<td><b>TC-C</b></td>
<td>0 to 1500 °C / 32 to 2732 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.5 °C / ± 1.0 °F</td>
<td>W5Re / W26Re</td>
</tr>
<tr>
<td></td>
<td>1500 to 2320 °C / 2732 to 4208 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.7 °C / ± 1.4 °F</td>
<td></td>
</tr>
<tr>
<td colspan="6">(*) Accuracy valid since the frequency output is not configured.<br />
(**) The Probe is a separate input used as reference thermometer. The related accuracy is relative only to the MCS-XV.<br />
(***) FS = Full Scale.</td>
</tr>
</tbody>
</table>
<table border="0" cellspacing="0" cellpadding="0">
<colgroup>
<col width="5%" />
<col width="15%" />
<col width="25%" />
<col width="17%" />
<col width="17%" />
<col width="21%" /></colgroup>
<tbody>
<tr>
<td></td>
<td colspan="6"><b>Specifications &#8211; Outputs</b></td>
</tr>
<tr>
<th rowspan="35"><img decoding="async" src="https://www.mcsxv.com/images/saidas_en.png" width="25px" border="0" /></th>
<td><b>milivolt</b></td>
<td>-10 to 110 mV</td>
<td>0.001 mV</td>
<td>± 0.02 % FS <sup>***</sup></td>
<td>R<sub>out</sub> &lt; 0.3 Ω</td>
</tr>
<tr>
<td><b>volt</b></td>
<td>-0.5 to 12 V</td>
<td>0.0001 V</td>
<td>± 0.02 % FS</td>
<td>R<sub>out</sub> &lt; 0.3 Ω</td>
</tr>
<tr>
<td><b>mA</b></td>
<td>0 to 24 mA</td>
<td>0.0001 mA</td>
<td>± 0.02 % FS</td>
<td>R<sub>max</sub> = 700 Ω</td>
</tr>
<tr>
<td><b>2-wire transmitter (XTR)</b></td>
<td>4 to 24 mA</td>
<td>0.0001 mA</td>
<td>± 0.02 % FS</td>
<td>V<sub>max</sub> = 60 V</td>
</tr>
<tr>
<td valign="top"><b>resistance</b></td>
<td valign="top">0 to 400 Ω</td>
<td valign="top">0.01 Ω</td>
<td valign="top">± 0.02 % FS</td>
<td valign="top">For external excitation current<br />
of 1.0 mA</td>
</tr>
<tr>
<td></td>
<td>0 to 2500 Ω</td>
<td>0.1 Ω</td>
<td>± 0.03 % FS</td>
<td></td>
</tr>
<tr>
<td><b>frequency</b></td>
<td>0 to 100 Hz</td>
<td>0.01 Hz</td>
<td>± 0.02 Hz</td>
<td>Peak value:</td>
</tr>
<tr>
<td></td>
<td>0 to 10000 Hz</td>
<td>1 Hz</td>
<td>± 2 Hz</td>
<td>22 V / 25 mA max.</td>
</tr>
<tr>
<td valign="top"><b>pulse</b></td>
<td valign="top">0 to 10<sup>8</sup> &#8211; 1 pulse</td>
<td valign="top">1 pulse</td>
<td valign="top"></td>
<td valign="top">Peak value:<br />
22 V / 25 mA max.<br />
Pulses frequency up to 10000 Hz</td>
</tr>
<tr>
<td><b>Pt-100</b></td>
<td>-200 to 850 °C / -328 to 1562 °F</td>
<td>0.01 °C / 0.01 °F</td>
<td>± 0.2 °C / ± 0.4 °F</td>
<td>IEC-60751</td>
</tr>
<tr>
<td><b>Pt-1000</b></td>
<td>-200 to 400 °C / -328 to 752 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.1 °C / ± 0.2 °F</td>
<td>IEC-60751</td>
</tr>
<tr>
<td><b>Cu-10</b></td>
<td>-200 to 260 °C / -328 to 500 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 2.0 °C / ± 4.0 °F</td>
<td>Minco 16-9</td>
</tr>
<tr>
<td><b>Ni-100</b></td>
<td>-60 to 250 °C / -76 to 482 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.2 °C / ± 0.4 °F</td>
<td>DIN-43760</td>
</tr>
<tr>
<td><b>TC-J</b></td>
<td>-210 to 1200 °C / -346 to 2192 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.4 °C / ± 0.8 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td><b>TC-K</b></td>
<td>-270 to -150 °C / -454 to -238 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.0 °C / ± 2.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>-150 to 1370 °C / -238 to 2498 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.4 °C / ± 0.8 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-T</b></td>
<td>-260 to -200 °C / -436 to -328 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.2 °C / ± 2.4 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>-200 to -75 °C / -328 to -103 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.8 °C / ± 1.6 °F</td>
<td></td>
</tr>
<tr>
<td></td>
<td>-75 to 400 °C / -103 to 752 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.4 °C / ± 0.8 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-B</b></td>
<td>50 to 250 °C / 122 to 482 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 5.0 °C / ± 10.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>250 to 500 °C / 482 to 932 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 3.0 °C / ± 6.0 °F</td>
<td></td>
</tr>
<tr>
<td></td>
<td>500 to 1200 °C / 932 to 2192 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 2.0 °C / ± 4.0 °F</td>
<td></td>
</tr>
<tr>
<td></td>
<td>1200 to 1820 °C / 2192 to 3308 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.4 °C / ± 2.8 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-R</b></td>
<td>-50 to 300 °C / -58 to 572 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 2.0 °C / ± 4.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>300 to 1760 °C / 572 to 3200 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.4 °C / ± 2.8 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-S</b></td>
<td>-50 to 300 °C / -58 to 572 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 2.0 °C / ± 4.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>300 to 1760 °C / 572 to 3200 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 1.4 °C / ± 2.8 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-E</b></td>
<td>-270 to -150 °C / -454 to -238 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.6 °C / ± 1.2 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>-150 to 1000 °C / -238 to 1832 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.2 °C / ± 0.4 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-N</b></td>
<td>-260 to -200 °C / -436 to -328 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 2.0 °C / ± 4.0 °F</td>
<td>IEC-60584</td>
</tr>
<tr>
<td></td>
<td>-200 to -20 °C / -328 to -4 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.8 °C / ± 1.6 °F</td>
<td></td>
</tr>
<tr>
<td></td>
<td>-20 to 1300 °C / -4 to 2372 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.4 °C / ± 0.8 °F</td>
<td></td>
</tr>
<tr>
<td><b>TC-L</b></td>
<td>-200 to 900 °C / -328 to 1652 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.4 °C / ± 0.8 °F</td>
<td>DIN-43710</td>
</tr>
<tr>
<td><b>TC-C</b></td>
<td>0 to 1500 °C / 32 to 2732 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.5 °C / ± 1.0 °F</td>
<td>W5Re / W26Re</td>
</tr>
<tr>
<td></td>
<td>1500 to 2320 °C / 2732 to 4208 °F</td>
<td>0.1 °C / 0.1 °F</td>
<td>± 0.7 °C / ± 1.4 °F</td>
<td></td>
</tr>
<tr>
<td colspan="6">The values of accuracy cover one year period and for a temperature range between 20 and 26 °C. Outside this range, the thermal stability is 0.001% FS / °C with reference<br />
to 23 °C. Thermocouple with internal cold junction compensation, one must consider the error of this cold junction compensation of up to ± 0.2 °C or ± 0.4 °F.</td>
</tr>
</tbody>
</table>
<table border="0" cellspacing="0" cellpadding="0">
<colgroup>
<col width="5%" />
<col width="15%" />
<col width="25%" />
<col width="17%" />
<col width="17%" />
<col width="21%" /></colgroup>
<tbody>
<tr>
<td></td>
<td colspan="6"><b>Specifications &#8211; Pressure</b></td>
</tr>
<tr>
<th rowspan="13"><img decoding="async" src="https://www.mcsxv.com/images/pressao_en.png" width="22" border="0" /></th>
<td><b>(0)</b></td>
<td>0 &#8211; 250 mmH20</td>
<td>0,001</td>
<td>± 0,05 % FS</td>
<td rowspan="3">Gage pressure.<br />
Used with air or inert gases.</td>
</tr>
<tr>
<td><b>(1)</b></td>
<td>0 &#8211; 1 psi</td>
<td>0,0001</td>
<td>± 0,05 % FS</td>
</tr>
<tr>
<td><b>(2)</b></td>
<td>0 &#8211; 5 psi</td>
<td>0,0001</td>
<td>± 0,025 % FS</td>
</tr>
<tr>
<td><b>(3)</b></td>
<td>0 &#8211; 15 psi</td>
<td>0,0001</td>
<td>± 0,025 % FS</td>
<td rowspan="10">Gage or absolute pressure.<br />
Used with fluids (gases or liquids) compatible with 316 L stainless steel.</td>
</tr>
<tr>
<td><b>(4)</b></td>
<td>0 &#8211; 30 psi</td>
<td>0,0001</td>
<td>± 0,025 % FS</td>
</tr>
<tr>
<td><b>(5)</b></td>
<td>0 &#8211; 100 psi</td>
<td>0,001</td>
<td>± 0,025 % FS</td>
</tr>
<tr>
<td><b>(6)</b></td>
<td>0 &#8211; 250 psi</td>
<td>0,001</td>
<td>± 0,025 % FS</td>
</tr>
<tr>
<td><b>(7)</b></td>
<td>0 &#8211; 500 psi</td>
<td>0,01</td>
<td>± 0,025 % FS</td>
</tr>
<tr>
<td><b>(8)</b></td>
<td>0 &#8211; 1000 psi</td>
<td>0,01</td>
<td>± 0,025 % FS</td>
</tr>
<tr>
<td><b>(9)</b></td>
<td>0 &#8211; 3000 psi</td>
<td>0,01</td>
<td>± 0,025 % FS</td>
<td></td>
</tr>
<tr>
<td><b>(10)</b></td>
<td>0 &#8211; 5000 psi</td>
<td>0,1</td>
<td>± 0,025 % FS</td>
</tr>
<tr>
<td><b>(11)</b></td>
<td>0 &#8211; 10000 psi</td>
<td>0,1</td>
<td>± 0,05 % FS</td>
</tr>
<tr>
<td><b>(12)</b></td>
<td>Others on request</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="6"></td>
</tr>
</tbody>
</table>
</div>
<div></div>
<p>The post <a href="https://rapid-tech.com.au/presys-mcs-xv-documenting-process-calibrator/">Documenting Process Calibrator With Full HART Communicator | PRESYS MCS-XV</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PRESYS LC-505 Process Loop Calibrator</title>
		<link>https://rapid-tech.com.au/presys-lc-505-process-loop-calibrator/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 28 Nov 2017 20:16:36 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=6070</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg"><img class="alignnone size-full wp-image-5972" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg" alt="" width="265" height="64" /></a></p>
<ul id="produto">
<li>Measures and generates standard <b>linear signals for current and voltage loops (mA and volts)</b>.</li>
<li>Designed for on-field use, it offers all advantages of a documenting calibrator.</li>
<li>Simultaneous input and output operation.</li>
<li>Internal regulated 24 Vdc power supply for 2-wire transmitters.</li>
<li>Special function for <b>transmitter calibration</b> converts any input signal into any output signal.</li>
<li>Square root function for mA input and output.</li>
<li>Generates, simulates and reads mA signals.</li>
<li>Automatic power off configuration to save battery.</li>
<li>Small, battery-operated, portable (rechargeable battery, charger and carrying case included).</li>
<li>Interfaces with Windows-based <b>Calibration Software Isoplan-5</b> to provide a true Computer-Aided Calibration System.</li>
<li>Real-time data acquisition capability when connected to a computer.</li>
</ul>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LC-505-Datasheet.pdf" rel="noopener noreferrer">PRESYS LC-505 Datasheet</a></h3>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LC-505-User-Manual.pdf" rel="noopener noreferrer">PRESYS LC-505 User Manual</a></h3>
<p style="text-align: center;"><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-Authorised.png"><img class="alignnone size-full wp-image-6055" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-Authorised.png" alt="" width="200" height="119" /></a></p>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/presys-lc-505-process-loop-calibrator/">PRESYS LC-505 Process Loop Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The PRESYS LC-505 Process Loop Calibrator enables measurement and generation of signals used in DC current (4-20mA) and voltage (1-5V, 0-10V) loops.</p>
<p>Distinguished from regular loop calibrators due to its high-accuracy, possibility of simultaneous measurement and generation of isolated signals, real time connection with computer, working as a data acquisition point and full computer-aid for instrument calibration and adjustment tasks.</p>
<p>Its accuracy refers to changes in room temperature and maintenance of specifications for a long time of use. Designed for field use, it contains useful items as carrying case holders with fastener rings or belts for a hands-free operation, a high contrast LCD for a better viewing in poor lighting conditions, besides presenting measured and generated signals with large digits so that they can be seen far away.</p>
<p>It includes rechargeable battery, and a high-size memory intended to store values obtained for a later upload to a computer, when applicable. Moreover, various other constructive features aggregate quality and efficiency to LC-505, allowing also its field and workbench use</p>
<h3>PRESYS LC-505 Process Loop Calibrator Specifications:</h3>
<table style="height: 221px;" width="771">
<tbody>
<tr>
<td width="189">
<h4><strong>Input Ranges</strong></h4>
</td>
<td width="95"><strong>Resolution</strong></td>
<td width="95"><strong>Accuracy</strong></td>
<td width="95"><strong>Remarks</strong></td>
</tr>
<tr>
<td width="189"><strong>VOLT  </strong></p>
<p>-10 to 11V</p>
<p>11 to 45V</td>
<td width="95">&nbsp;</p>
<p>0.0001 V</p>
<p>0.0001 V</td>
<td width="95">&nbsp;</p>
<p><u>+</u> 0.02% FS</p>
<p><u>+</u> 0.02% FS</td>
<td width="95">&nbsp;</p>
<p>RInput &gt;1MΩ</td>
</tr>
<tr>
<td width="189"><strong>mA </strong></p>
<p>-5 to 24.5mA</td>
<td width="95">&nbsp;</p>
<p>0.0001 mA</td>
<td width="95">&nbsp;</p>
<p><u>+</u> 0.02% FS</td>
<td width="95">&nbsp;</p>
<p>RInput &lt;160Ω</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table style="height: 315px;" width="771">
<tbody>
<tr>
<td width="183">
<h4><strong>Output Ranges</strong></h4>
</td>
<td width="92"><strong>Resolution</strong></td>
<td width="92"><strong>Accuracy</strong></td>
<td width="92"><strong>Remarks</strong></td>
</tr>
<tr>
<td width="183"><strong>VOLT </strong></p>
<p>-1 to 11V</td>
<td width="92">&nbsp;</p>
<p>0.0001 V</td>
<td width="92">&nbsp;</p>
<p><u>+</u> 0.02% FS</td>
<td width="92">&nbsp;</p>
<p>R output &lt;0.3Ω</td>
</tr>
<tr>
<td width="183"><strong>mA </strong></p>
<p>0 to 22mA</td>
<td width="92">&nbsp;</p>
<p>0.0001 mA</td>
<td width="92">&nbsp;</p>
<p><u>+</u> 0.02% FS</td>
<td width="92">&nbsp;</p>
<p>Rmax=700Ω</td>
</tr>
<tr>
<td width="183"><strong>2-Wire Transmitter (XTR) </strong></p>
<p>4mA to 22mA</td>
<td width="92">&nbsp;</p>
<p>0.0001 mA</td>
<td width="92">&nbsp;</p>
<p><u>+</u> 0.02% FS</td>
<td width="92">&nbsp;</p>
<p>V max= 60V</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>The post <a href="https://rapid-tech.com.au/presys-lc-505-process-loop-calibrator/">PRESYS LC-505 Process Loop Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>