<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Pressure Calibrators Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/pressure-calibrators/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/pressure-calibrators/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Mon, 23 Sep 2024 04:11:23 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.10</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>Pressure Calibrators Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/pressure-calibrators/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Pressure Calibrator &#124; PC-507-IS</title>
		<link>https://rapid-tech.com.au/pressure-calibrator-pc-507-is/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Thu, 29 Jul 2021 02:10:53 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=19019</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-5972" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg" alt="" width="265" height="64" /></p>
<p>The Pressure Calibrator PC-507-IS is an intrinsically safe calibrator suitable for use in hazardous (high explosive) areas like oil and gas. Can be operated in Group IIC Zone 0 which is the most demanding about the need for protection against electric sparks, it is the group of hydrogen and acetylene.</p>
<p><img class="size-full wp-image-17809 alignnone" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-Download-e1620015214396.png" alt="PDF Download icon" width="51" height="60" /> <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2021/07/encomenda_2_155.pdf" rel="noopener">PC-507-IS -Datasheet</a></p>
<p>The post <a href="https://rapid-tech.com.au/pressure-calibrator-pc-507-is/">Pressure Calibrator | PC-507-IS</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The front layout is different from the PC-507, in order to characterize unequivocally the Intrinsically Safe version. RS-232/485 serial communication port there for to connect to the computer. When used together with ISOPLAN® calibration software, it takes advantage of the documenting calibration concept which automatizes the calibration process, allowing data storage and sharing between calibrator and computer, improving efficiency in handling information, preparing report, issuing certificates, storage and registration of process instruments and sensors for an overall coverage of the quality procedure requirements, specially those related to ISO 9000.</p>
<p><strong>Key Features:</strong></p>
<ul id="produto">
<li>Up to four pressure sensors from 10&#8243; H₂O to 10,000 psi gauge or absolute pressure, including vacuum.</li>
<li>Measures differential pressure between any pair of sensors.</li>
<li>Measures and generates mA and volts.</li>
<li>Includes input for optional temperature probe.</li>
<li>Accuracy of 0.025% of full scale.</li>
<li>Pressure Switch test.</li>
<li>Portable, compact, powered by rechargeable batteries.</li>
<li>Power supply for 2-wire transmitters.</li>
<li>Serial communication.</li>
<li>PC-507-IS is an intrinsically safe pressure calibrator Ex ia IIC T4 Ga certified for usage in Ex-hazardous areas Zones 0, 1, and 2.</li>
</ul>
<p>The post <a href="https://rapid-tech.com.au/pressure-calibrator-pc-507-is/">Pressure Calibrator | PC-507-IS</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Presys PCON Kompressor-Y18 Pressure Calibrator</title>
		<link>https://rapid-tech.com.au/presys-pcon-kompressor-y18-pressure-calibrator/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Mon, 20 Nov 2017 22:18:26 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=5971</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg"><img class="alignnone size-full wp-image-5972" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg" alt="" width="265" height="64" /></a></p>
<p>The Presys PCON Kompressor-Y18 Pressure Calibrator provides a complete solution for the test and calibration of your pressure items.</p>
<p>The Presys PCON Kompressor-Y18 Pressure Calibrator isa vailable in Rack Mount and Field Service versions:</p>
<table border="0" width="100%">
<tbody>
<tr>
<td align="center"><a class="imagem1 cboxElement" title="PCON Kompressor-Y18 Rack Mount" href="https://www.presys.com.br//produtos/prod_g_235_1.png"><img src="https://www.presys.com.br/images/pcon_k_y18_rm.png" width="150px" /></a></td>
<td align="center"><a class="imagem1 cboxElement" title="PCON Kompressor-Y18 Field Service" href="https://www.presys.com.br//produtos/prod_g_235.png"><img src="https://www.presys.com.br/images/pcon_k_y18_fs.png" width="150px" /></a></td>
</tr>
<tr>
<td>Rack Mount</td>
<td>Field Service</td>
</tr>
</tbody>
</table>
<p>No extra software or computer is needed to generate the calibration test report on the fly and the data are tamper proofed in accordance with 21 CFR Part 11.</p>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="color: #0000ff;"><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-PCON-Y18-Brochures.pdf" target="_blank" rel="noopener">Presys PCON-Y18 Brochures</a></span></h3>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-Authorised.png"><img class="size-full wp-image-6055 aligncenter" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-Authorised.png" alt="" width="200" height="119" /></a></p>
<p>The post <a href="https://rapid-tech.com.au/presys-pcon-kompressor-y18-pressure-calibrator/">Presys PCON Kompressor-Y18 Pressure Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Presys PCON Kompressor-Y18 Pressure Calibrator is a real documenting automated calibrator to calibrate more efficiently your instruments in the industrial areas that will become quickly an indispensable tool in your day to day work allowing real gains of productivity.</p>
<h3>Presys PCON Kompressor-Y18 Pressure Calibrator Features:</h3>
<ul id="produto">
<li>5.7&#8243; Touch Screen Color Display. Dual Core 1 GHz processor and Flash memory of 16 GB.</li>
<li>Ethernet, Wi-Fi via USB/Ethernet router adapter, Serial USB with SCPI protocol.</li>
<li>Integrated WebServer, client-server technology to pick-up tasks on remote server.</li>
<li>Host/Device USB port.</li>
<li>Optional HART® / Profibus® Communication.</li>
<li>Pressure switch automatic testing.</li>
<li>Input Current: -1 to 24.5 mA, ± 0.01% FS.</li>
<li>Transmitter Power Supply: 24 Vdc regulated.</li>
<li>Leak test.</li>
<li>Temperature compensated accuracy from 0°C to 50°C.</li>
<li>User selectable pressure unit: Pa, hPa, kPa, MPa, bar, mbar, psi, mmHg@0°C,cmHg@0°C, mHg@0°C, inHg@0°C, inH<sub>2</sub>O@4°C, mmH<sub>2</sub>O@4°C, cmH<sub>2</sub>O@4°C, mH<sub>2</sub>O@4°C, mmH<sub>2</sub>O@20°C, cmH<sub>2</sub>O@20°C, mH<sub>2</sub>O@20°C, kg/m<sup>2</sup>, kg/cm<sup>2</sup>, mtorr, torr, atm, lb/ft<sup>2</sup>.</li>
<li>Control speed: 10 s (for 10 % FS pressure increase in a 50 ml test volume).</li>
<li>Integrated electric pump for positive and negative pressure generation.</li>
</ul>
<h3>Presys PCON Kompressor-Y18 Pressure Calibrator Standard Accessories:</h3>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-Konpressor-Y18-Accessories.jpg"><img fetchpriority="high" decoding="async" class="alignnone wp-image-5975" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-Konpressor-Y18-Accessories.jpg" alt="" width="654" height="391" srcset="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-Konpressor-Y18-Accessories.jpg 852w, https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-Konpressor-Y18-Accessories-300x179.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-Konpressor-Y18-Accessories-600x358.jpg 600w, https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-Konpressor-Y18-Accessories-768x459.jpg 768w" sizes="(max-width: 654px) 100vw, 654px" /></a></p>
<h3>Presys PCON Kompressor-Y18 Ordering Code:</h3>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-Konpressor-Y18-Order-Code.jpg"><img decoding="async" class="alignnone wp-image-5976" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-Konpressor-Y18-Order-Code.jpg" alt="" width="654" height="290" srcset="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-Konpressor-Y18-Order-Code.jpg 774w, https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-Konpressor-Y18-Order-Code-300x133.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-Konpressor-Y18-Order-Code-600x266.jpg 600w, https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-Konpressor-Y18-Order-Code-768x340.jpg 768w" sizes="(max-width: 654px) 100vw, 654px" /></a></p>
<p>The post <a href="https://rapid-tech.com.au/presys-pcon-kompressor-y18-pressure-calibrator/">Presys PCON Kompressor-Y18 Pressure Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		