<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Power Analyzer Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/power-analyzer/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/power-analyzer/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Sat, 06 Dec 2025 01:21:05 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.10</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>Power Analyzer Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/power-analyzer/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>PROVA 6200 Graphic Power Quality Analyzer &#124; Power Quality Clamps meter</title>
		<link>https://rapid-tech.com.au/prova-6200-graphic-power-quality-analyzer-power-quality-clamps-meter/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Thu, 03 Mar 2022 03:28:08 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=20963</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2016/02/Prova_Logo.gif"><img class="alignnone size-full wp-image-839" src="https://rapid-tech.com.au/wp-content/uploads/2016/02/Prova_Logo.gif" alt="" width="154" height="52" /></a></p>
<p><a target="_blank" href="https://mymeter.com.au/product/prova-6200-graphic-power-quality-analyzer-power-quality-clamps-meter/" rel="noopener"><img class="alignnone size-full wp-image-17843" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/BUY-NOW-form-My-Meter-e1620004827208.png" alt="Buy now form My Meter" width="220" height="55" /></a></p>
<p><span style="font-weight: 400;">PROVA 6200 is a power quality analyzer for single and balanced three phase systems. </span><span style="font-weight: 400;">With this power quality clamps meter, you can see a graphic waveform of voltage and current, as well as a phasor diagram. PROVA 6200 power quality analyzer is capable of data-logging and downloading to a PC.</span></p>
<p><img class="alignnone size-full wp-image-19718" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" />    <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2022/03/Prova-6200-Datasheet.pdf" rel="noopener">PROVA 6200 Datasheet</a></p>
<p>The post <a href="https://rapid-tech.com.au/prova-6200-graphic-power-quality-analyzer-power-quality-clamps-meter/">PROVA 6200 Graphic Power Quality Analyzer | Power Quality Clamps meter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span style="font-weight: 400;">PROVA 6200 is a power quality analyzer for single and balanced three phase systems. </span><span style="font-weight: 400;">With this power quality clamps meter, you can see a graphic waveform of voltage and current, as well as a phasor diagram. PROVA 6200 power quality analyzer is capable of data-logging and downloading to a PC.</span></p>
<p><strong>Features:</strong></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Power Quality Analysis for Single and Balanced Three Phase System.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Harmonic Analysis of Voltage and Current (1 to 50th order).</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">True RMS measurement of V with 0.5% of reading basic accuracy.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">True RMS measurement of A with 1% of reading basic accuracy.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Graphic Waveform of Voltage and Current.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Graphic Phasor Diagram.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Transient Detection and Logging of Swell, Dip, and Outage.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Fast peak function (39μs for 50 Hz, 33μs for 60Hz).</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Active (W, KW, HP), reactive (VAR, KVAR) and apparent (VA, KVA) power</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Power factor (PF), phase angle (Φ), and energy (WH, KWH, KVARH, PFH).</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Measurement of balanced 3Φ Power Quality.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Programmable VT ratio from 1 to 3000.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Hold functions.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Auto power off function in 15 minutes (selectable).</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Datalogging and Download to a PC.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Optical isolated USB data connection.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Unlimited datalogging facility on a PC.</span></li>
</ul>
<p>&nbsp;</p>
<p>The post <a href="https://rapid-tech.com.au/prova-6200-graphic-power-quality-analyzer-power-quality-clamps-meter/">PROVA 6200 Graphic Power Quality Analyzer | Power Quality Clamps meter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PROVA 23 Power Harmonics and Leakage Clamp Meter</title>
		<link>https://rapid-tech.com.au/prova-23-power-harmonics-and-leakage-clamp-meter/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Fri, 23 Nov 2018 01:22:28 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=9297</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2016/02/Prova_Logo.gif"><img class="alignnone size-full wp-image-839" src="https://rapid-tech.com.au/wp-content/uploads/2016/02/Prova_Logo.gif" alt="" width="154" height="52" /></a></p>
<p><a target="_blank" href="https://mymeter.com.au/product/prova-23-power-harmonics-and-leakage-tester/" rel="noopener"><img class="alignnone size-full wp-image-17843" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/BUY-NOW-form-My-Meter-e1620004827208.png" alt="Buy now form My Meter" width="220" height="55" /></a></p>
<p>The PROVA 23 Power Harmonics and Leakage Clamp Meter is a versatile instrument capable of measuring TRMS AC current and a wide range of power parameters, including Watts, active power, reactive power (VAR and KVAR), apparent power (VA and KVA), energy consumption (mWH, WH, and KWH), power factor (PF) and phase angle.</p>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2018/11/Prova-23-Datasheet.pdf" rel="noopener">Prova 23 Datasheet</a></span></h4>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2018/11/Prova-23-User-Manual.pdf" rel="noopener">Prova 23 User Manual</a></span></h4>
<p>The post <a href="https://rapid-tech.com.au/prova-23-power-harmonics-and-leakage-clamp-meter/">PROVA 23 Power Harmonics and Leakage Clamp Meter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4>PROVA 23 Power Harmonics and Leakage Clamp Meter Features:</h4>
<ul>
<li>True RMS value (V and A)</li>
<li>Leakage Current Measurement at 10 μ A Resolution</li>
<li>Harmonic Analysis (V and A) to the 99 th Order</li>
<li>High Frequency Harmonic Analysis (up to 5/6 KHz)</li>
<li>Non-interrupted Harmonic Analysis</li>
<li>Analysis of Total Harmonic Distortion (THD-F)</li>
<li>Analysis of Crest Factor (C.F.)</li>
<li>Fast Peak Function (33 μ s and 39 μ s)</li>
<li>Programmable CT Ratio (1 to 250)</li>
<li>100A</li>
</ul>
<h4>Measur</h4>
<h4>es:</h4>
<ul>
<li>W, KW, H.P.</li>
<li>VA, KVA, VAR, KVAR</li>
<li>PF, Phase Angle ( Φ )</li>
<li>Energy (mWH, WH, KWH)</li>
<li>Analysis of Standby Power Consumption</li>
<li>Balanced 3 Φ Power Quality</li>
</ul>
<h4>PROVA 23 Power Harmonics and Leakage Clamp Meter Specifications:</h4>
<h4><strong>AC Watts:</strong></h4>
<table width="613">
<tbody>
<tr>
<td colspan="6" width="613"><span style="font-size: 90%;">(50 or 60 Hz, PF 0.6~1, CT=1, Voltage is greater than AC 4V, Current is greater than AC 1mA for mA  range &amp; Current is greater than AC 0.04A for A range.Specification applies to continuous waveforms)</span></td>
</tr>
<tr>
<td width="187"><strong>Range (0 to 60A)</strong></td>
<td colspan="3" width="187"><strong>Resolution</strong></td>
<td colspan="2" width="239"><strong>Accuracy of Readings</strong></td>
</tr>
<tr>
<td width="187">0.050 – 9.999 W</td>
<td colspan="3" width="187">0.001W</td>
<td colspan="2" width="239">±2% ± 0.025W</td>
</tr>
<tr>
<td width="187">10.00 – 99.99 W</td>
<td colspan="3" width="187">0.01W</td>
<td colspan="2" width="239">±2% ± 0.25W</td>
</tr>
<tr>
<td width="187">100.0 &#8211; 999.9 W</td>
<td colspan="3" width="187">0.1W</td>
<td colspan="2" width="239">±2% ± 2.5W</td>
</tr>
<tr>
<td width="187">1.000 – 9.999 KW</td>
<td colspan="3" width="187">0.001 KW</td>
<td colspan="2" width="239">±2% ± 0.025KW</td>
</tr>
<tr>
<td width="187">10.00 – 99.99 KW</td>
<td colspan="3" width="187">0.01 KW</td>
<td colspan="2" width="239">±2% ± 0.25KW</td>
</tr>
<tr>
<td width="187">100.0 – 999.9 KW</td>
<td colspan="3" width="187">0.1 KW</td>
<td colspan="2" width="239">±2% ± 2.5KW</td>
</tr>
<tr>
<td width="187">1000 – 9999 KW</td>
<td colspan="3" width="187">1 KW</td>
<td colspan="2" width="239">±2% ± 25KW</td>
</tr>
<tr>
<td width="187">Range (60 – 100A)</td>
<td colspan="3" width="187">Resolution</td>
<td colspan="2" width="239">Accuracy</td>
</tr>
<tr>
<td width="187">0.050 – 9.999 W</td>
<td colspan="3" width="187">0.001W</td>
<td colspan="2" width="239">±2% of VA ± 5dgts</td>
</tr>
<tr>
<td width="187">10.00 – 99.99 W</td>
<td colspan="3" width="187">0.01W</td>
<td colspan="2" width="239">±2% of VA ± 5dgts</td>
</tr>
<tr>
<td width="187">100.0 &#8211; 999.9 W</td>
<td colspan="3" width="187">0.1W</td>
<td colspan="2" width="239">±2% of VA ± 5dgts</td>
</tr>
<tr>
<td width="187">1.000 – 9.999 KW</td>
<td colspan="3" width="187">0.001 KW</td>
<td colspan="2" width="239">±2% of VA ± 5dgts</td>
</tr>
<tr>
<td width="187">10.00 – 99.99 KW</td>
<td colspan="3" width="187">0.01 KW</td>
<td colspan="2" width="239">±2% of VA± 5dgts</td>
</tr>
<tr>
<td width="187">100.0 – 999.9 KW</td>
<td colspan="3" width="187">0.1 KW</td>
<td colspan="2" width="239">±2%of VA ± 5dgts</td>
</tr>
<tr>
<td width="187">1000 – 9999 KW</td>
<td colspan="3" width="187">1 KW</td>
<td colspan="2" width="239">±2% of VA ± 5dgts</td>
</tr>
</tbody>
</table>
<h4><strong>AC VOLTS:</strong></h4>
<table width="602">
<tbody>
<tr>
<td colspan="5" width="602"><span style="font-size: 90%;">(Auto Range, True RMS, Crest Factor&lt;4, Input Impedance 10 MΩ, Max. peak value 860VDC &amp; Overload Protection AC 800V)</span></td>
</tr>
<tr>
<td width="187"><strong>Range</strong></td>
<td width="127"><strong>Resolution</strong></td>
<td colspan="3" width="288"><strong>Accuracy of Readings (50/60Hz)</strong></td>
</tr>
<tr>
<td width="187">5V – 250 V</td>
<td width="127">0.1 V</td>
<td colspan="3" width="288">±0.5% ± 5dgts</td>
</tr>
<tr>
<td width="187">250 V – 600 V</td>
<td width="127">0.1 V</td>
<td colspan="3" width="288">±0.5% ± 5dgts</td>
</tr>
<tr>
<td width="187">Range</td>
<td width="127">Resolution</td>
<td colspan="3" width="288">Accuracy of Readings (45-1KHz)</td>
</tr>
<tr>
<td width="187">5V – 250 V</td>
<td width="127">0.1 V</td>
<td colspan="3" width="288">±1.5% ± 5dgts</td>
</tr>
<tr>
<td width="187">250 V – 600 V</td>
<td width="127">0.1 V</td>
<td colspan="3" width="288">±1.5% ± 5dgts</td>
</tr>
</tbody>
</table>
<h4><span style="font-size: 14.4px;"><br />
<span style="font-size: 100%;"><strong>AC CURRENT:</strong></span></span></h4>
<table width="602">
<tbody>
<tr>
<td colspan="5" width="602"><span style="font-size: 90%;">(Auto Range, True RMS, Crest Factor&lt;4, CT=1, Max. peak values 880mADC for mA range,</span></td>
</tr>
<tr>
<td colspan="5"><span style="font-size: 90%;"> 73.5ADC for A range, Overload Protection AC 600A)</span></td>
</tr>
<tr>
<td width="188"><strong>Range</strong></td>
<td colspan="2" width="125"><strong>Resolution</strong></td>
<td colspan="2" width="289"><strong>Accuracy of Readings (50/60Hz)</strong></td>
</tr>
<tr>
<td width="188">0.5 – 60mA</td>
<td colspan="2" width="125">0.01mA</td>
<td colspan="2" width="289">±0.5% ± 5dgts</td>
</tr>
<tr>
<td width="188">60 – 100mA</td>
<td colspan="2" width="125">0.01mA</td>
<td colspan="2" width="289">±0.5% ± 50dgts</td>
</tr>
<tr>
<td width="188">100 – 600 mA</td>
<td colspan="2" width="125">0.1 mA</td>
<td colspan="2" width="289">±0.5% ± 5dgts</td>
</tr>
<tr>
<td width="188">0.05 – 3 A</td>
<td colspan="2" width="125">0.001 A</td>
<td colspan="2" width="289">±0.5% ± 5dgts</td>
</tr>
<tr>
<td width="188">3 – 30 A</td>
<td colspan="2" width="125">0.01 A</td>
<td colspan="2" width="289">±0.5% ± 5dgts</td>
</tr>
<tr>
<td width="188">30 – 90 A</td>
<td colspan="2" width="125">0.01 A</td>
<td colspan="2" width="289">±1.0% ± 5dgts</td>
</tr>
<tr>
<td width="188">Range</td>
<td colspan="2" width="125">Resolution</td>
<td colspan="2" width="289">Accuracy of Readings (45-1KHz)</td>
</tr>
<tr>
<td width="188">0.5 – 60mA</td>
<td colspan="2" width="125">0.01mA</td>
<td colspan="2" width="289">±1.5% ± 5dgts</td>
</tr>
<tr>
<td width="188">60 – 100mA</td>
<td colspan="2" width="125">0.01mA</td>
<td colspan="2" width="289">±1.5% ± 50dgts</td>
</tr>
<tr>
<td width="188">100 – 600 mA</td>
<td colspan="2" width="125">0.1 mA</td>
<td colspan="2" width="289">±1.5% ± 5dgts</td>
</tr>
<tr>
<td width="188">0.05 – 3 A</td>
<td colspan="2" width="125">0.001 A</td>
<td colspan="2" width="289">±1.5% ± 5dgts</td>
</tr>
<tr>
<td width="188">3 – 30 A</td>
<td colspan="2" width="125">0.01 A</td>
<td colspan="2" width="289">±1.5% ± 5dgts</td>
</tr>
<tr>
<td width="188">30 – 90 A</td>
<td colspan="2" width="125">0.01 A</td>
<td colspan="2" width="289">±1.5% ± 5dgts</td>
</tr>
</tbody>
</table>
<h4>HARMONICS:</h4>
<table style="height: 489px;" width="639">
<tbody>
<tr>
<td colspan="6" width="614"><span style="font-size: 90%;">Harmonics of AC Voltage in Percentage   (1 to 99<sup>th</sup> order, minimum voltage at 50 or 60Hz is greater </span></td>
</tr>
<tr>
<td colspan="6"><span style="font-size: 90%;">than AC 80V. If the voltage is 0 at 50 or 60 Hz, all the percentage (%) display is 0.)</span></td>
</tr>
<tr>
<td colspan="2" width="200"><strong>Range</strong></td>
<td colspan="2" width="201"><strong>Resolution</strong></td>
<td colspan="2" width="213"><strong>Accuracy</strong></td>
</tr>
<tr>
<td colspan="2" width="200">1 – 10<sup>th</sup></td>
<td colspan="2">0.1 %</td>
<td colspan="2" width="213">±0.7% of reading ±1%</td>
</tr>
<tr>
<td colspan="2" width="200">11 – 20<sup>th</sup></td>
<td colspan="2">0.1 %</td>
<td colspan="2" width="213">±2% of reading ±1%</td>
</tr>
<tr>
<td colspan="2" width="200">21 – 50<sup>th</sup> (A range)</td>
<td colspan="2">0.1 %</td>
<td colspan="2" width="213">±5% of reading ±1%</td>
</tr>
<tr>
<td colspan="2" width="200">21 – 50<sup>th</sup> (mA range)</td>
<td colspan="2">0.1 %</td>
<td colspan="2" width="213">±10% of reading ±1%</td>
</tr>
<tr>
<td colspan="2" width="200">51 &#8211; 99<sup>th</sup></td>
<td colspan="2">0.1 %</td>
<td colspan="2" width="213">±35% of reading ±1%</td>
</tr>
<tr>
<td colspan="6"><strong>Harmonics of AC Voltage in Magnitude </strong>   (1 to 99<sup>th</sup> order, minimum voltage at 50 or 60 Hz is</td>
</tr>
<tr>
<td>greater than AC 80V)</td>
<td></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2" width="200"><strong>Range</strong></td>
<td colspan="2" width="201"><strong>Resolution</strong></td>
<td colspan="2" width="213"><strong>Accuracy</strong></td>
</tr>
<tr>
<td colspan="2" width="200">1 – 10<sup>th</sup></td>
<td colspan="2" width="201">0.1 V</td>
<td colspan="2" width="213">±0.7% of reading ±7dgts</td>
</tr>
<tr>
<td colspan="2" width="200">11 – 20<sup>th</sup></td>
<td colspan="2" width="201">0.1 V</td>
<td colspan="2" width="213">±2% of reading ±7dgts</td>
</tr>
<tr>
<td colspan="2" width="200">21 – 50<sup>th</sup> (A range)</td>
<td colspan="2" width="201">0.1 V</td>
<td colspan="2" width="213">±5% of reading ±7dgts</td>
</tr>
<tr>
<td colspan="2" width="200">21 – 50<sup>th</sup> (mA range)</td>
<td colspan="2" width="201">0.1 V</td>
<td colspan="2" width="213">±10% of reading ±7dgts</td>
</tr>
<tr>
<td colspan="2" width="200">51 &#8211; 99<sup>th</sup></td>
<td colspan="2" width="201">0.1 V</td>
<td colspan="2" width="213">±35% of reading ±7dgts</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table style="height: 295px;" width="676">
<tbody>
<tr>
<td colspan="6" width="614"><span style="font-size: 90%;">Harmonics of AC Current in Percentage    (1 to 99<sup>th</sup> order, minimum current at 50 or 60 Hz is greater than 100mA for mA range, and greater than 1A for A range. If the current is 0 at 50 or 60 Hz, all the percentage (%) display is 0.)</span></td>
</tr>
<tr>
<td colspan="2"></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2" width="200"><strong>Range</strong></td>
<td colspan="2" width="201"><strong>Resolution</strong></td>
<td colspan="2" width="213"><strong>Accuracy</strong></td>
</tr>
<tr>
<td colspan="2" width="200">1 – 10<sup>th</sup></td>
<td colspan="2">0.1 %</td>
<td colspan="2" width="213">±0.7% of reading ±1%</td>
</tr>
<tr>
<td colspan="2" width="200">11 – 20<sup>th</sup></td>
<td colspan="2">0.1 %</td>
<td colspan="2" width="213">±2% of reading ±1%</td>
</tr>
<tr>
<td colspan="2" width="200">21 – 50<sup>th</sup> (A range)</td>
<td colspan="2">0.1 %</td>
<td colspan="2" width="213">±5% of reading ±1%</td>
</tr>
<tr>
<td colspan="2" width="200">21 – 50<sup>th</sup> (mA range)</td>
<td colspan="2">0.1 %</td>
<td colspan="2" width="213">±10% of reading ±1%</td>
</tr>
<tr>
<td colspan="2" width="200">51 &#8211; 99<sup>th</sup></td>
<td colspan="2">0.1 %</td>
<td colspan="2" width="213">±35% of reading ±1%</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table width="613">
<tbody>
<tr>
<td colspan="6" width="549"><strong>Power Factor    </strong></p>
<p>(PF, ACV &gt; 4V, AC mA &gt; 1mA, AC A &gt; 0.04A, Watt &gt; 50 digits)</td>
<td width="64"></td>
</tr>
<tr>
<td colspan="2" width="200"><strong>Range</strong></td>
<td colspan="3" width="200"><strong>Resolution</strong></td>
<td colspan="2" width="213"><strong>Accuracy</strong></td>
</tr>
<tr>
<td colspan="2" width="200">0.000 – 1.000</td>
<td colspan="3">0.001</td>
<td colspan="2" width="213">±0.04</td>
</tr>
<tr>
<td colspan="3"><strong>Phase Angle </strong></p>
<p>(Φ, 50 or 60Hz)</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2" width="200"><strong>Range</strong></td>
<td colspan="3" width="200"><strong>Resolution</strong></td>
<td colspan="2" width="213"><strong>Accuracy</strong></td>
</tr>
<tr>
<td colspan="2" width="200">-180° to 180°</td>
<td colspan="3" width="200">0.1°</td>
<td colspan="2" width="213">± 2°</td>
</tr>
<tr>
<td colspan="2" width="200">0° to 360°</td>
<td colspan="3" width="200">0.1°</td>
<td colspan="2" width="213">± 2°</td>
</tr>
<tr>
<td colspan="3"><strong>Total Harmonic Distortion</strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="7"><span style="font-size: 90%;">(THD-F with respect to the first (fundamental) harmonics, min. value in the range from 45 to 65Hz is greater than AC 80V, greater than 1A for A range, and greater than 100mA for  mA range. Calculation is done over 1 to 50<sup>th</sup> Harmonics. If the voltage or current is 0 in the range from 45 to 65Hz, all the percentage (%) display is 0)</span></td>
</tr>
<tr>
<td colspan="2" width="200"><strong>Range (45~65Hz)</strong></td>
<td colspan="3" width="200"><strong>Resolution</strong></td>
<td colspan="2" width="213"><strong>Accuracy</strong></td>
</tr>
<tr>
<td colspan="2" width="200">0.0 – 20.0 %</td>
<td colspan="3">0.1%</td>
<td colspan="2" width="213">± 2%</td>
</tr>
<tr>
<td colspan="2" width="200">20.0 – 100%</td>
<td colspan="3">0.1%</td>
<td colspan="2" width="213">±3% of reading ± 5%</td>
</tr>
<tr>
<td colspan="2" width="200">100 – 999.9%</td>
<td colspan="3">0.1%</td>
<td colspan="2" width="213">±10% of reading ±10%</td>
</tr>
<tr>
<td colspan="7">Peak Value of AC Periodic Voltage (peak value&gt; 10V) or AC Periodic Current (peak value&gt;10mA   for   mA   range   and   peak   value&gt;0.5A   for   A   range)   for   continuous</td>
</tr>
<tr>
<td colspan="4">waveform except for square wave:</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2" width="200"><strong>Range</strong></td>
<td colspan="3" width="200"><strong>Sampling Time</strong></td>
<td colspan="2" width="213"><strong>Accuracy of Reading</strong></td>
</tr>
<tr>
<td colspan="2" width="200">50 Hz</td>
<td colspan="3" width="200">39 μs</td>
<td colspan="2" width="213">± 5% ± 30 digits</td>
</tr>
<tr>
<td colspan="2" width="200">60 Hz</td>
<td colspan="3" width="200">33 μs</td>
<td colspan="2" width="213">± 5% ± 30 digits</td>
</tr>
<tr>
<td colspan="7"><strong>Crest Factor</strong> (C.F.) of AC Voltage (peak value &gt; 10V) or AC Current (peak value&gt; 10mA  for  mA  range  and  peak  value&gt;0.5A  for  A  range)  for  continuous  waveform</td>
</tr>
<tr>
<td colspan="2">except for square wave:</td>
<td></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2" width="200"><strong>Range (45~65Hz)</strong></td>
<td colspan="3" width="200"><strong>Resolution</strong></td>
<td colspan="2" width="213"><strong>Accuracy of Readings</strong></td>
</tr>
<tr>
<td colspan="2" width="200">1.00 – 99.99</td>
<td colspan="3">0.01</td>
<td colspan="2" width="213">± 5% ± 30 digits</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table width="608">
<tbody>
<tr>
<td colspan="2" width="137"><strong>Frequency (Hz)</strong></td>
<td width="77"></td>
<td width="47"></td>
<td width="49"></td>
<td width="25"></td>
<td width="81"></td>
<td width="41"></td>
<td width="151"></td>
</tr>
<tr>
<td colspan="2" width="137"><strong>Range</strong></td>
<td colspan="2" width="124"><strong>Resolution</strong></td>
<td colspan="4" width="196"><strong>Accuracy of Readings</strong></td>
<td width="151"><strong>Allowed Input</strong></td>
</tr>
<tr>
<td colspan="2" width="137">mA (45 – 65Hz)</td>
<td colspan="2" width="124">0.1Hz</td>
<td colspan="4" width="196">± 0.5Hz</td>
<td width="151">20mA to 1.2A</td>
</tr>
<tr>
<td colspan="2" width="137">A (45 – 65Hz)</td>
<td colspan="2" width="124">0.1Hz</td>
<td colspan="4" width="196">± 0.5Hz</td>
<td width="151">1A to 100A</td>
</tr>
<tr>
<td colspan="7">Sensitivity: &gt; 20mA for mA range, &gt; 3A for A range, and &gt; 50V</td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="4"><strong><span style="font-size: 120%;">General Specifications:</span></strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="5" width="310">Conductor Size:</td>
<td colspan="4" width="298">30mm (approx.)</td>
</tr>
<tr>
<td colspan="5" width="310">Battery Type:</td>
<td colspan="4" width="298">two 1.5V SUM-3</td>
</tr>
<tr>
<td colspan="5" width="310">Display:</td>
<td colspan="4" width="298">4+2+2 digits LCD</td>
</tr>
<tr>
<td colspan="5" width="310">Range Selection:</td>
<td colspan="4" width="298">Auto</td>
</tr>
<tr>
<td colspan="5" width="310">Overload Indication:</td>
<td colspan="4" width="298">OL</td>
</tr>
<tr>
<td colspan="5" width="310">Power Consumption:</td>
<td colspan="4" width="298">10 mA (approx.)</td>
</tr>
<tr>
<td colspan="5" width="310">Low battery Indication:</td>
<td colspan="4" width="298">
<table>
<tbody>
<tr>
<td colspan="4" width="298"></td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td colspan="5" width="310">Auto-Power-Off:</td>
<td colspan="4" width="298">30 minutes after power-on</td>
</tr>
<tr>
<td colspan="5" width="310">Update Time:</td>
<td colspan="4" width="298">2 times/second (display)</td>
</tr>
<tr>
<td colspan="5" width="310">No. Of Samples per Period</td>
<td colspan="4" width="298">512 (voltage or current);<br />
256 (power)</td>
</tr>
<tr>
<td colspan="5" width="310">Temperature Coefficient (＜18℃ or  ＞28℃):</td>
<td colspan="4" width="298">0.15 x (Specified Accuracy) / ℃</td>
</tr>
<tr>
<td colspan="5" width="310">Operating Temperature:</td>
<td colspan="4" width="298">-10°C to 50°C</td>
</tr>
<tr>
<td colspan="5" width="310">Operating Humidity:</td>
<td colspan="4" width="298">less than 85% relative</td>
</tr>
<tr>
<td colspan="5" width="310">Altitude:</td>
<td colspan="4" width="298">up to 2000M</td>
</tr>
<tr>
<td colspan="5" width="310">Storage Temperature:</td>
<td colspan="4" width="298">-20°C to 60°C</td>
</tr>
<tr>
<td colspan="5" width="310">Storage Humidity:</td>
<td colspan="4" width="298">less than 75% relative</td>
</tr>
<tr>
<td colspan="5" width="310">Dimension:</td>
<td colspan="4" width="298">210mm (L) x 62mm (W) x 35.6mm (H)<br />
8.3&#8243; (L) x 2.5&#8243; (W) x 1.4&#8243; (H)</td>
</tr>
<tr>
<td colspan="5" width="310">Weight:</td>
<td colspan="4" width="298">200g (battery included)</td>
</tr>
<tr>
<td colspan="5" width="310">Accessories:</td>
<td colspan="4" width="298">Test leads x 1 pair, Carrying bag x 1, Users manual x 1,<br />
Batteries 1.5V x 2</td>
</tr>
<tr>
<td colspan="5" width="310">Option:</td>
<td colspan="4" width="298">Alligator clips</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/prova-23-power-harmonics-and-leakage-clamp-meter/">PROVA 23 Power Harmonics and Leakage Clamp Meter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PROVA AFLEX 6300 Graphic Power Quality Analyzer</title>
		<link>https://rapid-tech.com.au/prova-aflex-6300-graphic-power-quality-analyzer/</link>
					<comments>https://rapid-tech.com.au/prova-aflex-6300-graphic-power-quality-analyzer/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Thu, 10 Mar 2016 02:12:26 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=1522</guid>

					<description><![CDATA[<p>&#160;</p>
<p><img class="alignnone size-full wp-image-839" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/Prova_Logo.gif" alt="Prova_Logo" width="154" height="52" /></p>
<p>&#160;</p>
<p><b>Flexible probe, different from normal clamp meters, can pass through obstacles at will and wind many conducting wires simultaneously, maximum diameter 170mm.</b></p>
<h4><span style="font-size: large;">Features</span></h4>
<ul>
<li>Power Quality Analysis for Single and Balanced Three Phase Systems.</li>
<li>True RMS measurement of voltage with 0.5% basic accuracy.</li>
<li>True RMS measurement of current with 1% of range basic accuracy.</li>
<li>3000Amp.</li>
<li>Large LCD Display with Backlight.</li>
<li>Graphic Waveform of Voltage and Current.</li>
<li>Graphic Phasor Diagram.</li>
<li>Active Power (KW), Apparent (KVA) and Reactive Power (KVAR).</li>
<li>Power Factor and Phase Angle.</li>
<li>Energy (WH, KWH, KVARH, PFH).</li>
<li>Maximum Demand (MD in W, KW, MW) with Programmable Period.</li>
<li>Harmonic Analysis Volts and Current to 50th Order.</li>
<li>Display of 25 Harmonics on Screen.</li>
</ul>
<p>&#160;</p>
<h4><img class="alignnone size-full wp-image-1367" src="http://rapid-tech.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="logopdf (2)" width="58" height="58" /> <a href="http://rapid-tech.com.au/wp-content/uploads/2016/03/6300-Data-Sheet.pdf" rel="">6300-Data Sheet</a></h4>
<p>The post <a href="https://rapid-tech.com.au/prova-aflex-6300-graphic-power-quality-analyzer/">PROVA AFLEX 6300 Graphic Power Quality Analyzer</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The post <a href="https://rapid-tech.com.au/prova-aflex-6300-graphic-power-quality-analyzer/">PROVA AFLEX 6300 Graphic Power Quality Analyzer</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/prova-aflex-6300-graphic-power-quality-analyzer/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>