<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Phase Rotation Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/phase-rotation/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/phase-rotation/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Mon, 01 Jun 2026 02:42:17 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.7</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>Phase Rotation Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/phase-rotation/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>KYORITSU KEW 3552BT Insulation Tester &#124; 1000V Bluetooth</title>
		<link>https://rapid-tech.com.au/kyoritsu-kew-3552bt-insulation-continuity-tester/</link>
					<comments>https://rapid-tech.com.au/kyoritsu-kew-3552bt-insulation-continuity-tester/#respond</comments>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Mon, 01 Jun 2026 00:08:25 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=1119284</guid>

					<description><![CDATA[<p><img class="alignnone wp-image-770" src="https://mymeter.com.au/wp-content/uploads/2014/10/Kyoritsu.png" alt="" width="246" height="52" /></p>
<p><a target="_blank" href="https://mymeter.com.au/product/kyoritsu-kew-3552bt-insulation-continuity-tester/" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The KYORITSU KEW 3552BT is a fast, professional-grade insulation resistance and continuity tester built for electricians, solar installers and maintenance crews who can't afford to wait. With world's-fastest-class 0.5-second measurement, six test voltages up to 1000V, and Bluetooth 5.0 plus onboard memory for paperless reporting, it's ready to test straight out of the box. Verify, log, and certify — all in one rugged handheld.</p>
<p>&#160;</p>
<h4><img class="alignnone size-full wp-image-6653" src="https://mymeter.com.au/wp-content/uploads/2018/10/PDF-blue.png" alt="PDF download" width="43" height="54" /> <a target="_blank" href="https://www.kew-ltd.co.jp/en/download/dl/228/" rel="noopener" data-filename="/files/co/en/catalog/LC_3551_3552_3552BT_3_0_Low_en_P.pdf">KEW 3552BT Product Catalog (English)（1.20 MB)</a></h4>
<h4><img class="alignnone size-full wp-image-6653" src="https://mymeter.com.au/wp-content/uploads/2018/10/PDF-blue.png" alt="PDF download" width="43" height="54" /> <a target="_blank" href="https://www.kew-ltd.co.jp/en/download/dl/278/" rel="noopener" data-filename="/files/co/en/catalog/LC_KSA_4_0_A4_Low_en_P.pdf">KEW Smart Advanced Application Catalog (English)（13.33 MB)</a></h4>
<h4><img class="alignnone size-full wp-image-6653" src="https://mymeter.com.au/wp-content/uploads/2018/10/PDF-blue.png" alt="PDF download" width="43" height="54" /> <a target="_blank" href="https://www.kew-ltd.co.jp/en/download/dl/652/" rel="noopener" data-filename="/files/co/en/manual/IM_3551_3552_3552BT_92-2339C_en.pdf">KEW 3552BT Instruction Manual (English)（3.07 MB）</a></h4>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-kew-3552bt-insulation-continuity-tester/">KYORITSU KEW 3552BT Insulation Tester | 1000V Bluetooth</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold">The Problem: Slow Insulation Testing Is Costing You Billable Hours</h2>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Insulation resistance testing is non-negotiable. Whether you&#8217;re commissioning a new installation under AS/NZS 3000, verifying a solar array to AS/NZS 5033 and IEC 62446-1, or running scheduled maintenance on industrial switchboards, you have to prove the insulation holds up. The trouble is, traditional insulation testers can be painfully slow — waiting for readings to settle, manually transcribing results onto paper, then re-keying everything into a report back at the office.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">For a time-poor sparkie or solar tech doing dozens of tests a day, those wasted seconds and double-handled data points add up to real money and real risk. Transcription errors creep into compliance documents. Test certificates get delayed. And when a client or auditor asks for evidence, you&#8217;re digging through a clipboard instead of pulling a clean digital record.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h2 class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold">The Solution: Speed, Range and Wireless Reporting in One Handheld</h2>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The KYORITSU KEW 3552BT was engineered to strip the friction out of insulation and continuity testing. At its core is a measurement engine delivering <strong>world&#8217;s-fastest-class measurement speed of just 0.5 seconds</strong> — so you spend less time waiting at the probes and more time moving through the job.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">It covers <strong>six selectable insulation test voltages — 50V, 100V, 125V, 250V, 500V and 1000V</strong> — making it equally at home on low-voltage control circuits, standard 230V domestic and commercial wiring, and higher-voltage solar PV strings. The 1000V range pushes insulation resistance measurement up to 40GΩ, giving you the headroom needed for serious PV and industrial work.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Where the 3552BT really earns its keep is data. The &#8220;BT&#8221; model adds <strong>Bluetooth 5.0 wireless communication and internal memory</strong>, so every reading can be saved on the instrument and pushed straight to your phone or tablet via the free KEW Smart Advanced app. No clipboard, no re-keying, no transcription mistakes — just clean, time-stamped records ready to drop into a compliance report.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h2 class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold">Key Benefits That Matter on the Job</h2>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Lightning-fast 0.5-second measurement → more tests per day → higher productivity.</strong> When you&#8217;re working through a multi-circuit board or a string of solar panels, half-second readings let you keep a rhythm instead of standing around watching a display settle.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Six test voltages (50V to 1000V) → one tester for nearly every job → less gear in the ute.</strong> From sensitive electronics and control wiring at 50–125V, through standard installation testing at 250–500V, to solar and HV applications at 1000V, a single instrument has the range covered.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Bluetooth 5.0 + onboard memory → paperless, error-free reporting → faster certification.</strong> Save results on the tester, sync wirelessly to the KEW Smart Advanced app on Android or iOS, and generate professional reports without manual data entry. KEW Report PC software is also available for desktop reporting.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Automatic discharge → safer handling → peace of mind.</strong> When an insulation test finishes, any electric charge stored in the tested object is discharged automatically, protecting you from a nasty surprise on capacitive loads like cables and motor windings.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Continuity testing at 200mA → AS/NZS 3000-compliant earth checks → complete verification.</strong> Built-in low-resistance continuity testing lets you verify protective earthing and bonding conductors as part of the same workflow.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Rugged build with backlit display → works where you do → reliable in the field.</strong> A backlit LCD makes readings easy in dim switch rooms and roof cavities, and the robust housing is rated to handle the knocks of daily trade use.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h2 class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold">Technical Specifications</h2>
<div class="overflow-x-auto w-full px-2 mb-6">
<table class="min-w-full border-collapse text-sm leading-[1.7] whitespace-normal">
<thead class="text-left">
<tr>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">Specification</th>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">Value</th>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">Why It Matters</th>
</tr>
</thead>
<tbody>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Insulation test voltages</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">50 / 100 / 125 / 250 / 500 / 1000V</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Six ranges cover everything from control circuits to solar PV — one tester for the whole site</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Max insulation resistance</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">40.00GΩ (at 1000V)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Ample headroom for high-quality insulation on PV strings and industrial cabling</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Insulation accuracy</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">±2%rdg ±2dgt (first effective range)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Tight tolerance you can stand behind in a compliance certificate</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Measurement speed</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">0.5 sec (world&#8217;s fastest class)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">More tests per hour means more billable jobs completed each day</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Rated current</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">1.0 to 1.1mA</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Meets the load-current requirements for valid insulation testing</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Continuity range</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">40.00 / 400.0 / 4000Ω (auto-ranging)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Covers earth continuity and bonding checks under AS/NZS 3000</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Continuity accuracy</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">±2.5%rdg ±8dgt</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Dependable low-resistance readings for protective conductor verification</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Continuity test current</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">200mA max</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Sufficient test current for compliant continuity measurement</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Voltage measurement</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">AC 2.0–600V (45–65Hz), DC ±2.0–600V</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Confirms a circuit is dead before testing and doubles as a handy voltmeter</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Voltage accuracy</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">±1%rdg ±4dgt</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Trustworthy live-voltage detection for safe work practices</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Auto-discharge</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Yes</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Automatically discharges the tested object for safe handling</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Memory</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Internal memory (save measured results)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Store readings on the instrument for later sync and reporting</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Communication</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">USB + Bluetooth® 5.0</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Wireless data transfer to phone/tablet, USB for PC</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Compatible apps</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">KEW Smart Advanced, KEW Power (Android / iOS)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Free apps for live readings, data management and reporting</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Safety rating</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">CAT III 600V / CAT IV 300V</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Rated for use at the origin of the installation and distribution boards</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Standards</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">IEC 61010, IEC 61010-2-034, IEC 61557-1/2/4, IEC 61326-1/2-2</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Designed and tested to international measurement and safety standards</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Ingress protection</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">IP40</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Protected against solid objects over 1mm — suited to general site conditions</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Power source</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">4 × LR6/R6 (AA) 1.5V batteries</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Easy off-the-shelf battery replacement, no proprietary packs</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Dimensions</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">97(L) × 156(W) × 46(D) mm</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Compact enough for a tool pouch</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Weight</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Approx. 490g (incl. batteries)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Light enough for all-day handheld use</td>
</tr>
</tbody>
</table>
</div>
<blockquote class="ml-2 border-l-4 border-border-300/10 pl-4 text-text-300">
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Model family note:</strong> The 3550 series comes in three variants. The <strong>KEW 3551</strong> is the standard model, the <strong>KEW 3552</strong> adds memory, and the <strong>KEW 3552BT</strong> (this model) adds both memory <em>and</em> Bluetooth communication — the right choice if wireless reporting matters to your workflow.</p>
</blockquote>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h2 class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold">Applications &amp; Use Cases</h2>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Electrical contractors &amp; sparkies:</strong> Commission new installations and verify insulation resistance and earth continuity under the AS/NZS 3000 Wiring Rules. Run periodic testing on existing switchboards, submains and final subcircuits, then sync results for instant certificates.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Solar PV installers:</strong> Use the 500V and 1000V ranges to test PV array and string insulation resistance in line with AS/NZS 5033 and IEC 62446-1 commissioning requirements. The 40GΩ ceiling and fast readings make string-by-string testing efficient on big rooftop and ground-mount arrays — ideal for CEC-accredited installers documenting handover.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Industrial &amp; facility maintenance teams:</strong> Schedule predictive maintenance on motors, cables, transformers and control gear. Trend insulation resistance over time using saved memory data to catch degrading insulation before it becomes a failure or a shutdown.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Technical educators &amp; RTOs:</strong> A clear, fast, app-connected tester makes an excellent teaching instrument for TAFE and RTO electrical programs, letting students see live readings on a tablet via Bluetooth.</p>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-kew-3552bt-insulation-continuity-tester/">KYORITSU KEW 3552BT Insulation Tester | 1000V Bluetooth</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/kyoritsu-kew-3552bt-insulation-continuity-tester/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Tenmars TM-604N Three-Phase Motor Rotation Tester</title>
		<link>https://rapid-tech.com.au/tenmars-tm-604n-three-phase-motor-rotation-tester/</link>
					<comments>https://rapid-tech.com.au/tenmars-tm-604n-three-phase-motor-rotation-tester/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:12:05 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/tenmars-tm-604n-three-phase-motor-rotation-tester/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-928" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/Tenmars_logo_05-1.jpg" alt="Tenmars_logo_05" width="228" height="85" /></p>
<p><a target="_blank" href="https://mymeter.com.au/product/tenmars-tm-604n-three-phase-motor-rotation-tester/" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<p><strong><span style="font-size: large;">Tenmars TM-604N Three-Phase Motor Rotation Tester Features</span></strong></p>
<ul>
<li>Display by LED indicators.</li>
<li>Inter-phase voltage: 45V AC up to 600V AC.</li>
<li>Signal Frequency Range: 45Hz to 400Hz.</li>
<li>Test Currents inter-phase less than 3.5mA.</li>
<li>Two UL 500mA/700V fuse protection.</li>
<li>Low battery detection.</li>
</ul>
<p><span style="font-size: large;"> Applications</span></p>
<ul>
<li>Phase sequence testing. Three phase motor installation and maintenance.</li>
<li>Check motors for rotation direction.</li>
<li>Identifies the phase sequence of three phase electrical systems.</li>
<li>Indicates normal or reversed phases as well as loss of phase.</li>
</ul>
<p><strong>Authorised Australian distributor</strong></p>
<p><img class="alignnone size-full wp-image-1611" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="147" height="45" /></p>
<p>The post <a href="https://rapid-tech.com.au/tenmars-tm-604n-three-phase-motor-rotation-tester/">Tenmars TM-604N Three-Phase Motor Rotation Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<table border="0" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="2"><span style="font-size: large;">Tenmars TM-604N Three-Phase Motor Rotation Tester Ordering Information:</span></td>
</tr>
<tr>
<td colspan="2">
<div align="center">
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td align="left" bgcolor="#085aa5" width="233"><span style="color: #ffffff; font-size: medium;"> Model Name</span></td>
<td align="left" bgcolor="#085aa5" width="557"><span style="color: #ffffff; font-size: medium;"> Description</span></td>
</tr>
<tr>
<td align="left" valign="top" bgcolor="#e7f7ff" width="233">Tenmars TM-604N</td>
<td align="left" bgcolor="#e7f7ff" width="557">Three-Phase Motor Rotation Tester<br />
<b>Included accessories: </b> User&#8217;s manual, battery, carrying case, three test leads complete with removable alligator clips.</td>
</tr>
</tbody>
</table>
</div>
</td>
</tr>
</tbody>
</table>
<p>Safety and maintenance standards The instrument complies with : UL61010-1,and CSA C22.2 No.61010-1 (between ground and input terminal) and EN 61010-1(2001) and EN61557.  Operating altitude : below 2,000m.  Operating environment: for indoor use, expose to pollution level II.  This is a precision device. During use or storage, do not go beyond its spec. to prevent any possible damage or danger.  Do not put this device in direct sunlight or where it is hot and/or damp.  Remember to turn OFF the power after use. For long storage, remove the battery to prevent the battery from leaking to cause damage to the parts inside.  Clean the device with a dry soft cloth. Wet cloths, liquid and water are prohibited.</p>
<p>The post <a href="https://rapid-tech.com.au/tenmars-tm-604n-three-phase-motor-rotation-tester/">Tenmars TM-604N Three-Phase Motor Rotation Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/tenmars-tm-604n-three-phase-motor-rotation-tester/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Tenmars TM-601N Three-Phase Motor Rotation Tester</title>
		<link>https://rapid-tech.com.au/tenmars-tm-601n-three-phase-motor-rotation-tester/</link>
					<comments>https://rapid-tech.com.au/tenmars-tm-601n-three-phase-motor-rotation-tester/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Sun, 14 Feb 2016 15:12:05 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/tenmars-tm-601n-three-phase-motor-rotation-tester/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-928" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/Tenmars_logo_05-1.jpg" alt="Tenmars_logo_05" width="228" height="85" /></p>
<p><span style="font-size: large;">Features/Benefits</span></p>
<ul>
<li>Display by LED indicators.</li>
<li>Inter-phase voltage: 45V AC up to 600V AC.</li>
<li>Signal Frequency Range: 45Hz to 400Hz.</li>
<li>Test Currents inter-phase less than 3.5mA.</li>
<li>Two UL 500mA/700V fuse protection.</li>
<li>Low battery detection.</li>
<li>Waterproof resist.</li>
<li><span style="color: #000000;"><b>EN 61010-1 CAT III 1000V, CAT IV 600V EN 61557-7 safety rating</b></span></li>
</ul>
<p><span style="font-size: large;"> Applications</span></p>
<ul>
<li>Phase sequence testing. Three phase motor installation and maintenance.</li>
<li>Check motors for rotation direction.</li>
<li>Identifies the phase sequence of three phase electrical systems.</li>
<li>Indicates normal or reversed phases as well as loss of phase.</li>
</ul>
<p><strong>Authorised Australian Distributor</strong></p>
<p><img class="alignnone size-full wp-image-1611" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="147" height="45" /></p>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2016/02/Tenmars-TM-601N-Datasheet.pdf" rel="noopener"><span style="color: #0000ff;">Tenmars TM-601N Datasheet</span></a></h3>
<p>The post <a href="https://rapid-tech.com.au/tenmars-tm-601n-three-phase-motor-rotation-tester/">Tenmars TM-601N Three-Phase Motor Rotation Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<table border="0" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="2">
<div align="center">
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="2" bgcolor="#085aa5"><span style="color: #ffffff; font-size: medium;">Specifications</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="29%">Inter phase Voltage:</td>
<td bgcolor="#e7f7ff" width="70%">45V AC up to 600V AC.</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="29%">Signal Frequency Range:</td>
<td bgcolor="#e7f7ff" width="70%">45Hz to 400Hz.</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="29%">Inter Phase Test Currents:</td>
<td bgcolor="#e7f7ff" width="70%">less than 3.5mA.</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="29%">Dimensions:</td>
<td bgcolor="#e7f7ff" width="70%">143mm (L) x 68mm (W) x 35mm (D)</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="29%">Weight:</td>
<td bgcolor="#e7f7ff" width="70%">200g approx.</td>
</tr>
</tbody>
</table>
</div>
</td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2"><span style="font-size: large;">Ordering Information</span></td>
</tr>
<tr>
<td colspan="2">
<div align="center">
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td align="left" bgcolor="#085aa5" width="233"><span style="color: #ffffff; font-size: medium;"> Model Name</span></td>
<td align="left" bgcolor="#085aa5" width="557"><span style="color: #ffffff; font-size: medium;"> Description</span></td>
</tr>
<tr>
<td align="left" valign="top" bgcolor="#e7f7ff" width="233">Tenmars TM-601N</td>
<td align="left" bgcolor="#e7f7ff" width="557">Three-Phase Motor Rotation Tester<br />
<b>Included accessories:</b> User&#8217;s manual, 9 volt battery, carrying case, three test leads (4ft long) complete with removable alligator clips.</td>
</tr>
</tbody>
</table>
</div>
</td>
</tr>
</tbody>
</table>
<p>Safety precautions and procedures This instrument conforms with safety Standard EN 61010-1 related to electronic measuring instruments. For your own safety and to avoid damaging the instrument follow the procedures described in this instruction manual and read carefully all notes preceded by this symbol .</p>
<p>When taking measurements: </p>
<p>Avoid doing that in humid or wet places. Avoid doing that in rooms where explosive gas, combustible gas, steam or excessive dust is present. TM-601N/603/604 EN-13  Keep you insulated from the object under test. Do not touch exposed metal parts such as test lead ends, sockets, fixing objects, circuits etc.  Avoid doing that if you notice anomalous conditions such as breakages, deformations, fractures, leakages of battery liquid, blind display etc.  Be particularly careful when measuring voltages exceeding 20V to avoid risks of electrical shocks.</p>
<p>&nbsp;</p>
<p>The post <a href="https://rapid-tech.com.au/tenmars-tm-601n-three-phase-motor-rotation-tester/">Tenmars TM-601N Three-Phase Motor Rotation Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/tenmars-tm-601n-three-phase-motor-rotation-tester/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
