<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Meatest Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/meatest/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/meatest/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Wed, 13 May 2026 05:14:08 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>Meatest Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/meatest/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Meatest 9020 Multifunction Calibrator &#124; 9 ppm Lab Reference</title>
		<link>https://rapid-tech.com.au/meatest-9020-multifunction-calibrator-9-ppm-lab-reference/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Wed, 13 May 2026 02:07:40 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=1119235</guid>

					<description><![CDATA[<p><img class="alignnone wp-image-27271 " src="https://rapid-tech.com.au/wp-content/uploads/2023/12/Meatest-logo-300x109.png" alt="Meatest logo" width="248" height="90" /></p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Running a calibration lab means your reference standard has to be better than everything it tests — by a significant margin.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The Meatest 9020 is a bench-top multifunction calibrator that sources AC/DC voltage to 1050 V, current to 30 A, resistance, capacitance, power, temperature, and frequency from a single instrument, with a basic uncertainty of just 9 ppm.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Whether you're certifying 6½-digit DMMs, clamp meters, power analysers, insulation testers, or oscilloscopes, the 9020 handles your entire calibration workload — compliantly, traceably, and without compromise.</p>
<p><img class="alignnone size-full wp-image-19718" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" /> <a target="_blank" href="https://www.meatest.com/pages/File.aspx?id=3c317f12-a45a-4ee2-9a00-e10f1cfb31be" rel="noopener">Datasheets</a></p>
<p><img class="alignnone size-full wp-image-19718" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" /> <a target="_blank" href="https://www.meatest.com/pages/File.aspx?id=3e1cead1-d49d-40e8-8c7f-a8d2a0d5444f" rel="noopener">Manuals</a></p>
<p>The post <a href="https://rapid-tech.com.au/meatest-9020-multifunction-calibrator-9-ppm-lab-reference/">Meatest 9020 Multifunction Calibrator | 9 ppm Lab Reference</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">The Bottleneck Every Calibration Lab Knows</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">If your lab handles a mix of multimeters, clamp meters, power meters, and insulation testers, you&#8217;ve probably lived with the compromise: multiple reference sources, multiple setups, multiple opportunities for error.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Swapping between instruments mid-calibration wastes time, introduces connection uncertainty, and makes automated workflows unnecessarily complex. Add oscilloscope calibration to the mix and you&#8217;re looking at a second (or third) piece of kit occupying valuable bench space.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The Meatest 9020 Multifunction Calibrator is designed to eliminate that bottleneck. It consolidates the output functions your lab needs most — AC/DC voltage and current, resistance, capacitance, power, energy, temperature simulation, and frequency — into a single, rack-mountable reference instrument with a 9 ppm basic uncertainty.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">For labs servicing everything from handheld DMMs to 6½-digit bench meters, it covers the full workload without the clutter.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">One Instrument. Your Entire Electrical Calibration Workload.</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The 9020 is built around a broad-coverage output architecture designed for the realities of a mixed-instrument calibration lab. Here&#8217;s what it sources:</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>AC/DC Voltage (0 mV – 1050 V)</strong> Covers both DC and AC sine from 1 mVRMS to 1050 VRMS, with non-sine waveforms (sawtooth, triangle, square, truncated sine) available up to 200 VRMS. DC basic uncertainty is as low as 8 ppm of value on the 20 V range — suitable as a reference for all but the most demanding 8½-digit DMM calibrations. AC uncertainty runs to 160 ppm across the primary range. Frequency accuracy is 5 ppm with 5-digit resolution across the 3 Hz – 300 kHz span.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>AC/DC Current (0 µA – 30 A)</strong> The 9020 pushes current output to 30 A — making it well suited for calibrating high-range clamp meters used by industrial maintenance teams and energy monitoring specialists. With the optional 0950 Current Coil accessory, simulated current scales to 1500 A with a 45–65 Hz frequency range and 0.3 % additional uncertainty. DC current uncertainty is as low as 100 ppm on the mid-ranges, with AC uncertainty from 300 ppm at standard frequencies.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Resistance &amp; Capacitance</strong> Variable resistance simulation from 0 Ω to 1.1 GΩ with 6½-digit resolution and uncertainty as tight as 15 ppm (1 kΩ–100 kΩ fixed standards). Capacitance sources from 600 pF to 120 mF with 0.15% uncertainty across the primary range. Both 4-wire (Kelvin) and 2-wire modes are supported, with dedicated 2W-COMP mode for compensated 2-wire measurements.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>AC/DC Power &amp; Energy (40 µW – 31.5 kW)</strong> Power calibration spans DC to 1000 Hz across voltage and current combinations from 0.2 V/0.2 mA up to 1050 V/30 A. Phase shift uncertainty is 0.15° to 200 Hz. Total power accuracy on a 230 V/50 Hz EU grid with a 1 A load is 0.069 % of value — highly competitive for calibrating energy meters and power analysers used in sub-metering, solar PV monitoring, and industrial energy management. Harmonic distortion capability covers 50 harmonic products (15–1000 Hz fundamental), making the 9020 directly applicable to testing power quality instruments against harmonic content requirements.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Temperature Simulation (RTD &amp; Thermocouple)</strong> RTD simulation supports Pt385, Pt3916, Pt3926, Ni672, Cu427, Cu428, and custom curves with R0 range 20 Ω–2 kΩ. Uncertainty is 0.01–0.07 °C. Thermocouple support covers types A, B, C, D, E, G, J, K, L, M, N, R, S, T, U, and XK, with manual or automatic cold junction compensation via Adapter 91. TC uncertainty ranges 0.05–0.55 °C — adequate for calibrating all common industrial temperature instruments.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Frequency (0.1 Hz – 2 MHz)</strong> Square-wave frequency output at 100 mVpk, 1 Vpk, or 3 Vpk with 5 ppm accuracy and duty cycle control (0.1%–99.9%). Suitable for calibrating frequency-input process meters, panel instruments, and data loggers.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Built-In Process Multimeter</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">An optional internal measurement module (MER option) allows the 9020 to simultaneously source a stimulus signal and measure the device under test&#8217;s output — critical for calibrating transducers, loop-powered process transmitters, and industrial sensors. The built-in meter covers DC voltage (0–12 V), DC current (0–24 mA), resistance (0–20 kΩ), RTD and thermocouple temperature, and frequency (1 Hz–100 kHz).</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">This simultaneous source-and-measure capability simplifies transducer calibration workflows considerably and supports simulation of strain gauges and other bridge-type sensors via the 9000-60 cable accessory.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Oscilloscope Calibration Options</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Two scope calibration options extend the 9020&#8217;s frequency output into the RF domain:</p>
<ul class="[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3">
<li class="font-claude-response-body whitespace-normal break-words pl-2"><strong>SCO option</strong>: Levelled sine output to 400 MHz, pulse/time marker to 400 MHz, trigger output, and input impedance measurement (100 Ω / 2 MΩ). Amplitude uncertainty 0.5% + 350 µVpk at low frequency, extending to 3.7% at 400 MHz. Jitter &lt; 2 ns, rise time &lt; 1 ns.</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2"><strong>SC1 option</strong>: Extends levelled sine to 1.1 GHz (amplitude range 1.4 mVpk–1.5 Vpk to 1 GHz; 1.4 mVpk–1 Vpk above 1 GHz). Frequency uncertainty drops to 0.1 ppm in pulse/time marker mode.</li>
</ul>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">These options make the 9020 one of the few compact multifunction calibrators capable of supporting both bench instrument calibration and oscilloscope bandwidth verification from a single chassis.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">High Voltage Resistance for Insulation Tester Calibration</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The HVR option adds a dedicated high-voltage resistance output specifically designed for verifying insulation resistance testers and megaohmmeters. Resistance range spans 100 kΩ to 100 GΩ with test voltages to 1500 VDC. This is directly relevant to Australian labs calibrating instruments used under AS/NZS 3000 compliance programs, electrical safety testing, and NATA-accredited electrical calibration services. Resistance uncertainty is 0.2–3% depending on range; test voltage uncertainty 0.3%–1.5% + 5 V.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Automation and Lab Integration</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The 9020 ships with RS-232, IEEE-488 (GPIB), USB, and Ethernet interfaces as standard — making it straightforward to integrate with existing automated calibration platforms. For labs using Meatest&#8217;s own WinQbase or Caliber software, the 9020 supports the CamOCR optical readout module, which allows semi-automated calibration of instruments with no remote control interface — useful for legacy analogue meters and older DMMs. A full communication API is documented in the user manual for custom automation development.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Preset storage allows senior technicians to define verified output configurations that less experienced operators can recall and execute, reducing human error in high-throughput calibration environments.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Why It Suits Australian Calibration Labs</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Australian labs operating under NATA accreditation requirements need calibration sources with traceable uncertainty chains that clearly support the instruments under test. The 9020&#8217;s 12-month stability specifications — stated at 95% confidence, k=2 — satisfy the rigorous uncertainty budgeting requirements of ISO/IEC 17025.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Its coverage of insulation resistance (to 1.5 kV), power (AC/DC to 1050 V/30 A), and temperature simulation means a single instrument can support calibration of the test equipment categories most commonly used by Australian electrical contractors, industrial maintenance teams, and compliance testers working to AS/NZS 3000, AS/NZS 3017, and related standards.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">For calibration businesses and in-house labs looking to reduce instrument capital while maintaining accreditation-ready uncertainty performance, the 9020 represents a compelling consolidation investment.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h2 class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold">USE CASES</h2>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">1. NATA-Accredited Electrical Calibration Laboratories</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The 9020&#8217;s 9 ppm DC voltage accuracy and comprehensive multi-function output make it a primary reference source for calibrating multimeters, clamp meters, and bench DMMs across the full workload of a general electrical calibration lab.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Its IEC 61010 safety compliance and traceable uncertainty specifications align directly with ISO/IEC 17025 accreditation requirements.</p>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">2. Power Analyser and Energy Meter Calibration</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">With AC/DC power output to 31.5 kW (1575 kW with optional 0950 Current Coil), phase shift uncertainty of 0.15° to 200 Hz, and 50-harmonic generation capability, the 9020 is well-suited to calibrating single and three-phase power analysers, revenue-grade energy meters, and power quality instruments used in industrial sub-metering and solar PV grid connection applications.</p>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">3. Industrial Transducer and Process Meter Calibration</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The optional MER module enables simultaneous sourcing and measurement, supporting the calibration of loop-powered 4–20 mA transmitters, pressure and temperature transducers, and process meters. Combined with RTD and thermocouple simulation, this makes the 9020 valuable for industrial maintenance calibration teams in manufacturing, resources, and utilities sectors.</p>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">4. Oscilloscope Bandwidth Verification</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">With the SCO (400 MHz) or SC1 (1.1 GHz) option, the 9020 extends into oscilloscope calibration territory — delivering levelled sine signals, pulse/time markers, trigger outputs, and input impedance measurement from the same chassis that handles DC voltage reference work.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">This suits calibration service providers who need oscilloscope capability without a dedicated RF calibrator.</p>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">5. Insulation Tester and Megohmeter Calibration</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The HVR option provides test voltages to 1500 VDC with resistance simulation from 100 kΩ to 100 GΩ — directly addressing the calibration requirements for insulation resistance testers (Meggers) used across Australia&#8217;s electrical contracting, industrial, and infrastructure sectors, where compliance with AS/NZS 3000 and AS/NZS 3760 is mandatory.</p>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">6. Electrical Safety Test Equipment Calibration Services</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Calibration service providers offering certificate-of-calibration services to electrical contractors, facilities managers, and industrial clients can use the 9020 to support PAT tester, loop tester, and installation tester calibration programmes. The instrument&#8217;s broad output coverage reduces the number of reference sources required and simplifies multi-function service delivery.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h2 class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold">TECHNICAL SPECIFICATIONS</h2>
<div class="overflow-x-auto w-full px-2 mb-6">
<table class="min-w-full border-collapse text-sm leading-[1.7] whitespace-normal">
<thead class="text-left">
<tr>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">Parameter</th>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">Specification</th>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">Why It Matters</th>
</tr>
</thead>
<tbody>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Basic DC Voltage Uncertainty</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">8–30 ppm (range dependent, 1-year, k=2)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Sets the minimum uncertainty budget for all DMM and voltmeter calibrations</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>DC Voltage Range</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">0 mV – 1050 V</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Covers full low-voltage span from signal-level to mains-equivalent</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>AC Voltage Range</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">1 mVRMS – 1050 VRMS, 3 Hz – 300 kHz</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Covers audio-frequency through RF-adjacent calibration requirements</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>DC Current Range</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">0 µA – 30 A</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Calibrates clamp meters and high-range ammeters directly</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>AC Current Range</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">10 µARMS – 30 ARMS, 10 Hz – 30 kHz</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Enables full AC clamp meter and current transducer calibration</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Current Output (with 0950 Coil)</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Up to 1500 A simulated</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Required for large clamp meter calibration (e.g. 1000 A range)</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Resistance Range</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">0 Ω – 1.1 GΩ (variable); 0 Ω – 1 GΩ (fixed standards)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Full coverage for DMM, LCR meter, and ohmmeter calibration</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Resistance Uncertainty (15 ppm)</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">1 kΩ – 100 kΩ fixed standards</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Supports 6½-digit DMM calibration at reference-grade accuracy</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Capacitance Range</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">600 pF – 120 mF</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Calibrates capacitance meters and LCR instruments across practical ranges</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Capacitance Uncertainty</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">0.12–0.45% (range dependent)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Sufficient for all commercial and trade-grade capacitance meter calibration</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Power Range</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">40 µW – 31.5 kW (DC + AC 15–1000 Hz)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Covers sub-watt signal-level through high-power three-phase meter calibration</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Power Accuracy (230 V/50 Hz, 1 A)</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">0.069% of value</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Meets revenue meter calibration requirements in Australian energy sector</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Harmonic Distortion Output</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">50 products, 15–1000 Hz fundamental</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Validates power quality analyser harmonic measurement performance</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Phase Shift Uncertainty</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">0.15° (≤200 Hz), 0.25° (&gt;200 Hz)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Directly affects power factor and reactive power calibration accuracy</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Temperature (RTD)</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Pt385, Pt3916, Pt3926, Ni672, Cu427, Cu428, custom</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Covers all common industrial RTD standards</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>RTD Uncertainty</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">0.01–0.07 °C</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Laboratory-grade temperature simulation for calibrating RTD transmitters</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Temperature (TC)</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Types A, B, C, D, E, G, J, K, L, M, N, R, S, T, U, XK</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Broadest thermocouple type coverage available in this class</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>TC Uncertainty</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">0.05–0.55 °C</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Adequate for all common industrial TC instrument calibration</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Frequency Range</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">0.1 Hz – 2 MHz</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Calibrates frequency-input panel meters, counters, and data loggers</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Frequency Accuracy</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">5 ppm</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Excellent for general-purpose frequency meter calibration</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Scope Option (SCO)</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Levelled sine to 400 MHz</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Oscilloscope bandwidth calibration without a dedicated RF calibrator</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Scope Option (SC1)</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Levelled sine to 1.1 GHz</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">High-bandwidth oscilloscope calibration for service and metrology labs</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Insulation Resistance (HVR Option)</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">100 kΩ – 100 GΩ, up to 1500 VDC</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Calibrates insulation testers and megaohmmeters used in electrical compliance</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Interfaces</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">RS-232, IEEE-488 (GPIB), USB, Ethernet</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Full automation compatibility; no additional interface cards required</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Safety Compliance</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">IEC 61010 ed. 2 (Safety Class I), EN 61326 (ESD Class I), Overvoltage CAT II</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Meets laboratory safety requirements</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Operating Temperature</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">+13 °C – +33 °C</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Standard lab environment; reference temperature 21–25 °C</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Warm-Up Time</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">30 minutes</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Standard for instruments of this class; plan calibration schedules accordingly</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Power Supply</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">115/230 V, 50/60 Hz, 450 VA max</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Compatible with Australian 230 V/50 Hz mains supply</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Dimensions (W × H × D)</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">434 × 191 × 641 mm</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Standard 3U/4U rack-mountable bench footprint</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Weight</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">24–25 kg (options dependent)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Bench-use instrument; not designed for field transport</td>
</tr>
</tbody>
</table>
</div>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h2 class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold">AVAILABLE OPTIONS</h2>
<div class="overflow-x-auto w-full px-2 mb-6">
<table class="min-w-full border-collapse text-sm leading-[1.7] whitespace-normal">
<thead class="text-left">
<tr>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">Option Code</th>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">Description</th>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">Best For</th>
</tr>
</thead>
<tbody>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>SCO</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Oscilloscope calibration to 400 MHz; includes N/BNC adapter</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Labs calibrating general-purpose oscilloscopes</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>SC1</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Oscilloscope calibration to 1.1 GHz; includes N/BNC adapter</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Service labs with high-bandwidth scope calibration requirements</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>HVR</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">High voltage resistance to 1.5 kV; includes 191-11 5 kV cable</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Labs calibrating insulation testers and megaohmmeters</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>MER</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Process multimeter option; includes 9000-60 4W measurement cable</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Transducer and process meter calibration, strain gauge simulation</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>0950 Current Coil</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Multiplication factors 10×, 25×, 50×; max 1500 A</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Large clamp meter and high-current instrument calibration</td>
</tr>
</tbody>
</table>
</div>
<blockquote>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>What is the Meatest 9020 used for?</strong> The Meatest 9020 is a bench-top multifunction calibrator used in electrical calibration laboratories to verify and calibrate a wide range of electrical test instruments. It sources AC and DC voltage (up to 1050 V), AC and DC current (up to 30 A), resistance, capacitance, power, energy, temperature (RTD and thermocouple), and frequency from a single instrument. Optional modules extend its capability to oscilloscope calibration (to 1.1 GHz) and insulation resistance tester calibration (to 1500 VDC). It is designed for labs calibrating multimeters, clamp meters, power analysers, energy meters, process meters, and transducers.</p>
</blockquote>
<blockquote>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>What is the accuracy of the Meatest 9020?</strong> The Meatest 9020 has a basic DC voltage uncertainty of 9 ppm (with the best range achieving 8 ppm of value over 12 months at k=2, 95% confidence). AC voltage uncertainty is from 160 ppm, DC current from 100 ppm, and AC power accuracy at 230 V/50 Hz is approximately 0.069–0.142% depending on current level. All specifications are all-inclusive: they cover 12-month stability, temperature effects, linearity, load regulation, and calibration traceability.</p>
</blockquote>
<blockquote>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Can the Meatest 9020 calibrate insulation testers?</strong> Yes. With the HVR (High Voltage Resistance) option, the Meatest 9020 can calibrate insulation resistance testers and megaohmmeters. The HVR option provides resistance simulation from 100 kΩ to 100 GΩ at test voltages up to 1500 VDC, covering the full measurement range of insulation testers used in electrical safety compliance testing. A 5 kV-rated test cable (191-11) is included with the HVR option.</p>
</blockquote>
<p>The post <a href="https://rapid-tech.com.au/meatest-9020-multifunction-calibrator-9-ppm-lab-reference/">Meatest 9020 Multifunction Calibrator | 9 ppm Lab Reference</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Meatest 9000 &#8211; Advanced Portable Multifunction Calibrator for 3.5 and 4.5 Digit Multimeters – Lightweight and Compact with Enhanced Features</title>
		<link>https://rapid-tech.com.au/meatest-9000-advanced-portable-multifunction-calibrator-for-3-5-and-4-5-digit-multimeters-lightweight-and-compact-with-enhanced-features/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Mon, 18 Dec 2023 22:49:40 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=27269</guid>

					<description><![CDATA[<p><img class="alignnone wp-image-27271 " src="https://rapid-tech.com.au/wp-content/uploads/2023/12/Meatest-logo-300x109.png" alt="Meatest logo" width="248" height="90" /></p>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Discover the <b><strong class="font-bold">Meatest 9000 Portable Multifunction Calibrator</strong></b>, a game-changer in the world of calibrations.</p>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">This compact device, specifically designed for calibrating 3.5 and 4.5 digit multimeters, offers a basic accuracy of 60 ppm and includes a smart terminal layout for cable-free operations. It's lightweight, portable and perfect for onsite calibrations. Enhanced features like wider frequency ranges, new capacitance function, and stronger outputs set it apart.</p>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Compatible with CALIBER/WinQBase, the 9000 enables efficient remote control and automation in labs and on industrial test rigs.</p>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Upgrade your calibration process with the <b><strong class="font-bold">Meatest 9000</strong></b>. Order now, and experience the difference!</p>
<p><img class="alignnone size-full wp-image-19718" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" />  <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2023/12/9000d.pdf" rel="noopener">Meatest 9000 Datasheet</a><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2022/08/MEATEST-9010-Multifunction-Calibrator-User-Manual-.pdf" rel="noopener"></a></p>
<p>The post <a href="https://rapid-tech.com.au/meatest-9000-advanced-portable-multifunction-calibrator-for-3-5-and-4-5-digit-multimeters-lightweight-and-compact-with-enhanced-features/">Meatest 9000 &#8211; Advanced Portable Multifunction Calibrator for 3.5 and 4.5 Digit Multimeters – Lightweight and Compact with Enhanced Features</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 class="font-bold text-gray-800 text-h3 leading-[36px] pt-[21px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]" dir="ltr">Experience the Meatest 9000 Portable Multifunction Calibrator &#8211; Your Perfect Calibration Solution</h2>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Immerse yourself in the ultimate calibration experience with the <b><strong class="font-bold">Meatest 9000 Portable Multifunction Calibrator</strong></b>. This all-in-one device, perfectly designed for calibrating 3.5 and 4.5 digit multimeters, boasts a basic accuracy of 60 ppm and eliminates the need for tedious cable switching with its smart terminal layout.</p>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Engineered with features that exceed its predecessor, the M143, the 9000 offers a wider range of frequencies, a new capacitance function, and stronger outputs. It&#8217;s designed to handle the modern day workload, including LoZ function calibration, process meters, and even panel meters.</p>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Despite its high functionality, the <b><strong class="font-bold">Meatest 9000</strong></b> maintains a compact and lightweight design. Its briefcase size and 11 kg weight make it an ideal companion for onsite calibrations. The friendly interface, marked by a generous 8” touchscreen display, ensures easy operation even with inaccurate inputs.</p>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">What&#8217;s more? With USB, Ethernet, and IEEE488 interfaces, the 9000 promotes remote control and automation in calibration labs as well as on industrial test rigs. It&#8217;s fully compatible with the Meatest calibration software package CALIBER/WinQBase, which includes the CamOCR Camera Readout Module, making handheld multimeter calibration a breeze.</p>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Upgrade your calibration process with the <b><strong class="font-bold">Meatest 9000 Portable Multifunction Calibrator</strong></b>. It&#8217;s more than a device; it&#8217;s a game-changer in the world of calibrations. Order now and experience the difference!</p>
<h4 class="font-bold text-gray-800 text-body leading-[24px] pt-[12px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]" dir="ltr">HIGHLIGHTS</h4>
<ul class="pt-[9px] pb-[2px] pl-[24px] list-disc [&amp;_ul]:pt-[5px] pt-[5px]">
<li class="text-body font-regular text-gray-800 leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="1">All-round calibrator for 3.5 and 4.5 digit multimeters</li>
<li class="text-body font-regular text-gray-800 leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="2">1050 V, 20.5 A, resistance, capacitance, TC, RTD and frequency</li>
<li class="text-body font-regular text-gray-800 leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="3">Basic accuracy 60 ppm</li>
<li class="text-body font-regular text-gray-800 leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="4">Terminal layout eliminates need for cable switching</li>
<li class="text-body font-regular text-gray-800 leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="5">Compact, light, ideal for onsite calibrations</li>
</ul>
<p>The post <a href="https://rapid-tech.com.au/meatest-9000-advanced-portable-multifunction-calibrator-for-3-5-and-4-5-digit-multimeters-lightweight-and-compact-with-enhanced-features/">Meatest 9000 &#8211; Advanced Portable Multifunction Calibrator for 3.5 and 4.5 Digit Multimeters – Lightweight and Compact with Enhanced Features</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MEATEST 9010+ Multifunction Calibrator</title>
		<link>https://rapid-tech.com.au/meatest-9010-plus-multifunction-calibrator/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Thu, 18 Aug 2022 04:41:10 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=22675</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-28" src="https://rapid-tech.com.au/wp-content/uploads/2015/12/MEATEST_logo_PL.jpg" alt="" width="125" height="28" /></p>
<p>MEATEST 9010+ Multifunction Calibrator can be used to calibrate multimeters, power meters, and a variety of other electric meters. With its modular design, the 9010+ can also be customized to calibrate oscilloscopes, insulation testers, sources, and transducers. So whether you need a basic calibration or something more specific, this calibrator has you covered. And with a 10 ppm AC/DC rating, you can be confident in the results. So make your life easier with the 9010+ multifunction calibrator.</p>
<p>Features</p>
<ul>
<li>10 ppm accuracy</li>
<li>400 MHz and 1.1 GHz scope options</li>
<li>Power quality functions, voltage from current</li>
</ul>
<p><img class="alignnone size-full wp-image-19718" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" />  <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2022/08/MEATEST-9010-Multifunction-Calibrator-Datasheet.pdf" rel="noopener">MEATEST 9010+ Multifunction Calibrator Datasheet</a></p>
<p><img class="alignnone size-full wp-image-19718" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" />  <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2022/08/MEATEST-9010-Multifunction-Calibrator-User-Manual-.pdf" rel="noopener">MEATEST 9010+ Multifunction Calibrator User Manual</a></p>
<p>The post <a href="https://rapid-tech.com.au/meatest-9010-plus-multifunction-calibrator/">MEATEST 9010+ Multifunction Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="justify"><div class="epyt-video-wrapper"><iframe  id="_ytid_63444"  width="1020" height="574"  data-origwidth="1020" data-origheight="574"  data-relstop="1" src="https://www.youtube.com/embed/YxUdeCNytk4?enablejsapi=1&autoplay=0&cc_load_policy=0&cc_lang_pref=&iv_load_policy=1&loop=0&rel=0&fs=1&playsinline=1&autohide=2&theme=dark&color=red&controls=1&disablekb=0&" class="__youtube_prefs__  no-lazyload" title="9010+ Multifunction Calibrator"  allow="fullscreen; accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen data-no-lazy="1" data-skipgform_ajax_framebjll=""></iframe></div>
<p align="justify">&#8211;</p>
<p align="justify">Multifunction calibrator 9010+ is designed as universal calibration tool for electrical calibration laboratories, covering most of their workload like 6½ digit multimeters, clamp meters, ohm meters, power meters and power analysers, energy meters, transducers, insulation testers, process meters, oscilloscopes and many others. High load capacity of voltage output (up to 50 mA) allows for calibration of high-consumption analogue meters. Installed harmonic and non-harmonic shape signals allow for testing meter sensitivity to distorted signals by a signal with various crest factor.<br />
9010+ takes advantage of 9010&#8217;s wide workload coverage and modern user interface ans pushes its performance even further by accuracy improvements in most functions, current range extension to 30 A, power range extension to 1575 kW and ultimately 1.1 GHz o-scope calibration capability with SC1 option (expected in 12/2022).</p>
<h3>Built-in multimeter</h3>
<p align="justify">Internal multimeter with basic capability to measure VDC, IDC, R and F process signals is optionally available in 9010+. Meter functions can run simultaneously with source functions to measure and evaluate output signals of various types of transducers as well as external sensors (strain gauge, pressure, torsion, force, etc.).</p>
<h3>User comfort</h3>
<p align="justify">9010+ calibrator is focused on user friendliness making calibrations simple and straightforward. Each function has its dedicated chunky button and all relevant details like total uncertainty, limits or connection scheme are shown on large LCD. Various output setups can be saved as Presets and recalled from memory when needed. This way a skilled technician can define verified presets for other operators, avoiding human error and streamlining manual calibration.<br />
9010+ can be operated remotely via RS-232, GPIB, USB or Ethernet as part of custom automated solutions (complete communication API is described in user manual) or in WinQbase/Caliber automated calibration systems featuring automated optical UUT readouts.</p>
<h3>Upgrade options</h3>
<p align="justify">Customers using 9010 Multifunction Calibrators with serial numbers 750381 and higher can request upgrade to 9010+ Multifunction Calibrator. Upgrades will be done in Meatest CZ with 6 week average lead time, starting in November 2022.<br />
9010+ internal options SCO, HVR, MER can be retrofitted at any time. SC1 retrofits will be available from 2023. Ask your local Meatest representative for lead times and pricing.</p>
<p>The post <a href="https://rapid-tech.com.au/meatest-9010-plus-multifunction-calibrator/">MEATEST 9010+ Multifunction Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MEATEST 9010 Multifunction Calibrator</title>
		<link>https://rapid-tech.com.au/meatest-9010-multifunction-calibrator/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Thu, 06 Dec 2018 10:11:09 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=9416</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-28" src="https://rapid-tech.com.au/wp-content/uploads/2015/12/MEATEST_logo_PL.jpg" alt="" width="125" height="28" /></p>
<p>The new MEATEST 9010 is a 35 ppm AC/DC multifunction calibrator for multimeters, power meters and generally all kinds of electric meters. Implementing modular design, 9010 can be further customized to calibrate oscilloscopes, insulation testers, sources and transducers.</p>
<p><strong>Features</strong></p>
<div class="product__description highlights texts-default">
<ul>
<li>35 ppm accuracy</li>
<li>400 MHz scope option</li>
<li>Power quality functions, voltage from current</li>
</ul>
</div>
<h4><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" />    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-9010-Datasheet.pdf" rel="noopener"><span style="font-size: 110%;">Meatest 9010 Datasheet</span></a></span></h4>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-9010-User-Manual.pdf" rel="noopener">Meatest 9010 User Manual</a></span></h4>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-9010-Remote-Control-Manual.pdf" rel="noopener">Meatest 9010 Remote Control Manual</a></span></h4>
<p>The post <a href="https://rapid-tech.com.au/meatest-9010-multifunction-calibrator/">MEATEST 9010 Multifunction Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="epyt-video-wrapper"><iframe  id="_ytid_61371"  width="1020" height="574"  data-origwidth="1020" data-origheight="574"  data-relstop="1" src="https://www.youtube.com/embed/in4Cg_gMYuQ?enablejsapi=1&autoplay=0&cc_load_policy=0&cc_lang_pref=&iv_load_policy=1&loop=0&rel=0&fs=1&playsinline=1&autohide=2&theme=dark&color=red&controls=1&disablekb=0&" class="__youtube_prefs__  no-lazyload" title="9010 Multifunction Calibrator"  allow="fullscreen; accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen data-no-lazy="1" data-skipgform_ajax_framebjll=""></iframe></div>
<p>&#8211;</p>
<p>When the 9100E Multifunction Calibrator ceased production it left a hole in the market for a versatile (50ppm) workhorse calibrator that is able to handle a wide workload of calibration including Insulation Testers, Clamps,  Power Meters &amp; if required, Oscilloscopes. &#8211;  Well now the MEATEST 9010 Multifunction Calibrator with it&#8217;s ± 35 ppm/year DC accuracy is able to fill these calibration needs.</p>
<p align="justify">The MEATEST 9010 Multifunction Calibrator is designed as universal calibration tool for electrical calibration laboratories, covering most of their workload like multimeters, clamp meters, ohm meters, power meters and power analysers, energy meters, transducers, insulation testers, process meters, scopes and many others.</p>
<p align="justify">High load capacity of voltage output (up to 50 mA) allows for calibration of high-consumption analogue meters. Installed harmonic and non-harmonic shape signals allow for testing meter sensitivity to distorted signals by a signal with various crest factor. Advancing from previous M14x calibrator series, 9010 can now calibrate even 400 MHz scopes, 1.5 kV insulation testers and 280 kW power meters.</p>
<p align="justify">It has all the popular functions including complete transducer and external sensor calibration (strain gauge, pressure, torsion, force, etc.) using optional built-in multimeter, automatic uncertainty calculation, remote control and easy recalibration.</p>
<h3 align="justify">MEATEST 9010 Features</h3>
<ul>
<li>AC/DC voltage/current up to <strong>1050V/20A</strong></li>
<li>Basic uncertainty <strong>35 ppm</strong></li>
<li><strong>AC/DC power, energy, resistance, capacitance, frequency, TC, RTD</strong></li>
<li><strong>Scope option</strong> up to 400 MHz</li>
<li>High voltage resistance option for <strong>1.5 kV insulation testers</strong></li>
<li>Built-in process multimeter</li>
<li>Interface <strong>RS232, LAN, USB, GPIB</strong></li>
</ul>
<h3>Built-in multimeter</h3>
<p align="justify">An Internal multimeter with basic capability to measure VDC, IDC, R and F process signals is optionally available in 9010. Meter functions can run simultaneously with source functions to measure and evaluate output signals of various types of transducers as well as external sensors (strain gauge, pressure, torsion, force, etc.).</p>
<h3>User comfort</h3>
<p align="justify">The Meatest 9010 calibrator is focused on user friendliness making calibrations simple and straightforward. Each function has its dedicated chunky button and all relevant details like total uncertainty, limits or connection scheme are shown on large LCD. Relative deviation feature can help you with UUT error calculation and this intuitive user environment will even allow you to adjust all internal functions and ranges with no additional equipment.</p>
<p align="justify">The 9010 can be operated remotely via GPIB or RS-232 and can be used both in custom automated solutions (complete communication API is described in user manual) or in WinQbase/Caliber automated calibration systems featuring automated optical UUT readouts.</p>
<h3 align="justify">MEATEST 9010 Front Panel</h3>
<p align="justify"><a href="https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Front-Pannel.jpg"><img decoding="async" class="alignnone wp-image-16571 size-medium" src="https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Front-Pannel-300x157.jpg" alt="" width="300" height="157" srcset="https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Front-Pannel-300x157.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Front-Pannel-600x314.jpg 600w, https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Front-Pannel.jpg 750w" sizes="(max-width: 300px) 100vw, 300px" /></a></p>
<p align="justify">1. Output terminals<br />
2. Display<br />
3. Numeric and navigation keys<br />
4. Function keys<br />
5. Input terminals<br />
6. Softkeys (sky blue) and menu keys (grey)</p>
<h3 align="justify">MEATEST 9010 Multifunction Calibrator Specifications</h3>
<table class="vychoziTabulka">
<tbody>
<tr>
<td>DC voltage</td>
<td>0 &#8211; 1050 V<br />
± 35 ppm / year</td>
</tr>
<tr>
<td>AC voltage</td>
<td>1 mV &#8211; 1050 V, 15 Hz &#8211; 300 kHz<br />
sinusoidal &amp; non-sinusoidal waveforms, harmonics<br />
± 250 ppm / year</td>
</tr>
<tr>
<td>DC current</td>
<td>0 &#8211; 20 A (1000 A with 140-50 Current Coil)<br />
± 150 ppm / year</td>
</tr>
<tr>
<td>AC current</td>
<td>10 uA &#8211; 20 A, 15 Hz &#8211; 10 kHz (1000 A with 140-50 Current Coil)<br />
sinusoidal &amp; non-sinusoidal waveforms, harmonics<br />
± 500 ppm / year</td>
</tr>
<tr>
<td>DC Power &amp; Energy</td>
<td>40 uW &#8211; 5.6 kW (280 kW with 140-50 Current Coil)<br />
± 210 ppm / year</td>
</tr>
<tr>
<td>AC Power &amp; Energy</td>
<td>40 uW &#8211; 5.6 kW, 15 &#8211; 1000 Hz (280 kW with 140-50 Current Coil)<br />
50 harmonic products, voltage from current<br />
± 730 ppm / year</td>
</tr>
<tr>
<td>Resistance</td>
<td>0 Ω &#8211; 1 GΩ, resolution 6½ digits<br />
± 15 ppm / year</td>
</tr>
<tr>
<td>Insulation Resistance</td>
<td>100 kΩ &#8211; 100 GΩ<br />
rated up to 1.5 kV</td>
</tr>
<tr>
<td>Capacitance</td>
<td>800 pF &#8211; 120 mF, resolution 6½ digits<br />
± 0.5 % / year</td>
</tr>
<tr>
<td>Temperature</td>
<td>TC BCDEG<sub>2</sub>JKMNRST with cold junction compensation<br />
RTD ± 0.03°C / year</td>
</tr>
<tr>
<td>Frequency</td>
<td>0.1 Hz &#8211; 400 MHz<br />
± 25 ppm / year</td>
</tr>
</tbody>
</table>
<h3>Process Multimeter</h3>
<table class="vychoziTabulka" style="height: 280px;" width="559">
<tbody>
<tr>
<td>DC voltage</td>
<td>0 &#8211; 12 V<br />
mVDC resolution down to 10 nV<br />
± 50 ppm / year</td>
</tr>
<tr>
<td>DC current</td>
<td>0 &#8211; 24 mA<br />
± 150 ppm / year</td>
</tr>
<tr>
<td>Resistance</td>
<td>0 Ω &#8211; 20 kΩ, resolution 6½ digits<br />
± 200 ppm / year</td>
</tr>
<tr>
<td>Temperature</td>
<td>TC BCDEG<sub>2</sub>JKMNRST<br />
RTD ± 0.08°C / year</td>
</tr>
<tr>
<td>Frequency</td>
<td>1 Hz &#8211; 100 kHz<br />
± 50 ppm / year</td>
</tr>
</tbody>
</table>
<h3>Optional Accessories​</h3>
<table class="vychoziTabulka">
<tbody>
<tr class="accessories__row">
<td class="accessories__cell"><a href="https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Current-Coil-140-50.jpg"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-16567" src="https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Current-Coil-140-50.jpg" alt="" width="400" height="180" srcset="https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Current-Coil-140-50.jpg 400w, https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Current-Coil-140-50-300x135.jpg 300w" sizes="auto, (max-width: 400px) 100vw, 400px" /></a></td>
<td class="accessories__cell accessories__cell--description">
<div class="accessories__cell accessories__cell--title">Current Coil 140-50</div>
<p>multiplication factors x25 and x50, 1500 A maximum</td>
</tr>
<tr class="accessories__row">
<td class="accessories__cell"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-16568" src="https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Adapter-9000-60.jpg" alt="" width="400" height="212" srcset="https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Adapter-9000-60.jpg 400w, https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Adapter-9000-60-300x159.jpg 300w" sizes="auto, (max-width: 400px) 100vw, 400px" /></td>
<td class="accessories__cell accessories__cell--description">
<div class="accessories__cell accessories__cell--title">Adapter 9000-60</div>
<p>for resistance and RTD measurement</td>
</tr>
<tr class="accessories__row">
<td class="accessories__cell"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-16569" src="https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Adapter-91.jpg" alt="" width="400" height="214" srcset="https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Adapter-91.jpg 400w, https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Adapter-91-300x161.jpg 300w" sizes="auto, (max-width: 400px) 100vw, 400px" /></td>
<td class="accessories__cell accessories__cell--description">
<div class="accessories__cell accessories__cell--title">Adapter 91</div>
<p>Pt100 cold junction compensator</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/meatest-9010-multifunction-calibrator/">MEATEST 9010 Multifunction Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MEATEST M525 Programmable Capacitance Decade</title>
		<link>https://rapid-tech.com.au/meatest-m525-programmable-capacitance-decade/</link>
					<comments>https://rapid-tech.com.au/meatest-m525-programmable-capacitance-decade/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 28 Mar 2017 02:40:53 +0000</pubDate>
				<guid isPermaLink="false">http://rapid-tech.com.au/?post_type=product&#038;p=4874</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-28" src="http://rapid-tech.com.au/wp-content/uploads/2015/12/MEATEST_logo_PL.jpg" alt="MEATEST_logo_PL" width="125" height="28" /></p>
<div class="productDetailText">
<p>The MEATEST M525 Programmable Capacitance Decade is a programmable capacitance decade with continuous range from 100 pF to 100 uF. Based on M6xx Real-Resistance decade series for great user comfort.</p>
</div>
<ul>
<li>0.25% accuracy, maximum voltage 50 V</li>
<li>Grounded / floating operation</li>
<li>User defined conversion tables</li>
</ul>
<h4><span style="color: #ff0000;">Authorised Australian Distributor</span></h4>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a style="color: #0000ff; text-decoration: underline;" href="http://rapid-tech.com.au/wp-content/uploads/2017/03/M525-Datasheet.pdf" target="_blank" rel="noopener">M525 Datasheet</a></span></span></h5>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a style="color: #0000ff; text-decoration: underline;" href="http://rapid-tech.com.au/wp-content/uploads/2017/03/M525-Operation-Manual.pdf" target="_blank" rel="noopener">M525 Operation Manual</a></span></span></h5>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/meatest-m525-programmable-capacitance-decade/">MEATEST M525 Programmable Capacitance Decade</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The MEATEST M525 Programmable Capacitance Decade is designed for checking multimeters and simple LRC meter. It is suitable also for repair, adjustment and calibration of measuring instruments. Capacitance value is created via appropriate combination of physical capacitors. Capacitors are switched using special relays designed for high currents. Actual set values are displayed on high resolution TFT display. Comfortable user interface offers direct setting of capacity value, OPEN correction, grounding L terminal, user conversion curves setting and others.</p>
<p>The MEATEST M525 Programmable Capacitance Decade is equipped with an internal calibration menu that allows correcting any deviation of capacity value without opening the instrument and has it&#8217;s own re-calibration procedure. The procedure enables to correct any deviation in capacitance without any mechanical adjusting. Decade can be remotely controlled by a computer using standard RS232 interface. LAN, USB and GPIB interfaces are optional.</p>
<p>The MEATEST M525 Programmable Capacitance Decade is a precise capacitance decade box with range from 100 pF to 100 µF. Basic accuracy is 0.25 %. Best resolution on the lowest range is 1 pF. Capacitors are switched using special relays designed for high currents. Comfortable user interface offers direct setting of capacity value, OPEN correction, grounding L terminal, user conversion curves setting and others. Decade can be remotely controlled by a computer using standard RS232 interface. LAN, USB and GPIB interfaces are optional. The M525 is equipped with an internal calibration menu that allows correcting any deviation of capacity value without opening the instrument. Decade is designed for checking multimeters and simple RLC meter. It is suitable also for repair, adjustment and calibration of measuring instruments.</p>
<h4>General Specification</h4>
<ul>
<li>Maximum voltage: 50 V pk</li>
<li>Temperature coefficient: &lt; 270 ppm/°C</li>
<li>Reaction time: &lt; 200 ms</li>
<li>Reaction time TIMING : min 500 ms</li>
<li>Terminals: gold plated terminals 4mm</li>
<li>Remote control: RS232 interface (optionally USB, LAN, IEEE488)</li>
<li>Power supply: 85-260 Vac, 45-65 Hz</li>
<li>Reference temperatures: +23°C ± 2°C</li>
<li>Working temperatures: +5°C … +40°C</li>
<li>Dimensions: W 390 mm, H 128 mm, D 310 mm</li>
<li>Weight: 4 kg</li>
</ul>
<p>The post <a href="https://rapid-tech.com.au/meatest-m525-programmable-capacitance-decade/">MEATEST M525 Programmable Capacitance Decade</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/meatest-m525-programmable-capacitance-decade/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Meatest M191 Insulation Tester Calibrator</title>
		<link>https://rapid-tech.com.au/meatest-m191-insulation-tester-calibrator/</link>
					<comments>https://rapid-tech.com.au/meatest-m191-insulation-tester-calibrator/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 28 Mar 2017 02:12:09 +0000</pubDate>
				<guid isPermaLink="false">http://rapid-tech.com.au/?post_type=product&#038;p=4869</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-28" src="http://rapid-tech.com.au/wp-content/uploads/2015/12/MEATEST_logo_PL.jpg" alt="MEATEST_logo_PL" width="125" height="28" /></p>
<div class="productDetailText">
<p>High resistance calibrator for insulation testers up to 10 kV. Other insulation related functions include HV capacitance, short current, dielectric and polarization parameters and timer test.</p>
</div>
<ul>
<li>Six different calibration functions</li>
<li>1 TΩ and 10 kVdc limits</li>
<li>Test voltage and current indication</li>
</ul>
<h4><span style="color: #ff0000;">Authorised Australian Distributor</span></h4>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2017/03/M191-Datasheet.pdf" rel="noopener">M191 Datasheet</a></span></span></h5>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2017/03/M191-Operation-Manual.pdf" rel="noopener">M191 Operation Manual</a></span></span></h5>
<p>The post <a href="https://rapid-tech.com.au/meatest-m191-insulation-tester-calibrator/">Meatest M191 Insulation Tester Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Meatest M191 Insulation Tester Calibrator is designed for the calibration of insulation testers. It can be used for calibration of any DC high resistance meter with working voltage up to 10 kV.</p>
<p>Meatest M191 Insulation Tester Calibrator is based on programmable high resistance decade which is completed with additional electronic circuits allowing calibration not only resistance ranges, but also calibration of test voltage generated by UUT, testing of short current, verifying of functions of measuring dielectric parameters like polarization index (PI), dielectric absorption ratio (DAR) and polarization ratio (PR). The calibrator enables also verification of timer function of UUTs.</p>
<p>Basic feature of the Meatest M191 Insulation Tester Calibrator is adjustable high resistance decades in the range from 10 kΩ to 1 TΩ. The decade is designed for operation voltages up to 10 kV. In this range it offers basic accuracy 0.1% to 5 % depending on set resistance value.</p>
<p>The calibration can be controlled manually using front panel keypad or in remote mode using one of two types of interfaces GPIB, or RS-232.</p>
<p>The Meatest M191 Insulation Tester Calibrator can easily integrate within calibration systems featuring CALIBER software support.</p>
<h4>Meatest M191 Insulation Tester Calibrator Specifications:</h4>
<table class="vychoziTabulka" style="height: 90px;" width="666">
<tbody>
<tr>
<td>DC resistance</td>
<td>10 kΩ &#8211; 1 TΩ, 10.5 kV max.<br />
± 0.1% / year</td>
</tr>
<tr>
<td>DC capacitance</td>
<td>10 nF, 50nF, 100 nF, 5.25 kV max.<br />
± 0.5% / year</td>
</tr>
</tbody>
</table>
<h3>Test Signal Meter</h3>
<table class="vychoziTabulka" style="height: 137px;" width="391">
<tbody>
<tr>
<td>DC voltage</td>
<td>50 V &#8211; 10.5 kV<br />
± 0.5% / year</td>
</tr>
<tr>
<td>DC current</td>
<td>0 &#8211; 5 mA<br />
± 0.2% / year</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/meatest-m191-insulation-tester-calibrator/">Meatest M191 Insulation Tester Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/meatest-m191-insulation-tester-calibrator/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>MEATEST M109R High Resistance Decade</title>
		<link>https://rapid-tech.com.au/meatest-m109r-high-resistance-decade/</link>
					<comments>https://rapid-tech.com.au/meatest-m109r-high-resistance-decade/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Mon, 27 Mar 2017 04:53:16 +0000</pubDate>
				<guid isPermaLink="false">http://rapid-tech.com.au/?post_type=product&#038;p=4863</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-28" src="http://rapid-tech.com.au/wp-content/uploads/2015/12/MEATEST_logo_PL.jpg" alt="MEATEST_logo_PL" width="125" height="28" /></p>
<div class="productDetailText">
<p>The MEATEST M109R High Resistance Decade is a mechanical high resistance decade with RS232 remote control for voltages up to 5 kV. Internal battery for up to 3 hours of on site use.</p>
</div>
<ul>
<li>12 GΩ and 5 kVdc limits</li>
<li>Voltage limit indication</li>
<li>Battery-powered</li>
<li>Remote control via RS232 bus</li>
</ul>
<h4><span style="color: #ff0000;">Authorised Australian Distributor</span></h4>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a style="color: #0000ff; text-decoration: underline;" href="http://rapid-tech.com.au/wp-content/uploads/2017/03/M109R-Datasheet.pdf" target="_blank" rel="noopener">M109R Datasheet</a></span></span></h5>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a style="color: #0000ff; text-decoration: underline;" href="http://rapid-tech.com.au/wp-content/uploads/2017/03/M109R-Operation-Manual.pdf" target="_blank" rel="noopener">M109R Operation Manual</a></span></span></h5>
<p>The post <a href="https://rapid-tech.com.au/meatest-m109r-high-resistance-decade/">MEATEST M109R High Resistance Decade</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="justify">The MEATEST M109R High Resistance Decade is designed for calibration of insulation meters and megohmmeters and resistance ranges of safety testers, HIPOT testers or any other DC high resistance meter with test voltage up to 5 kV. Maximum voltage rating is indicated on front panel to ensure safety in operation.</p>
<p align="justify">The MEATEST M109R High Resistance Decade&#8217;s internal rechargeable battery lasts for up to 3 hours of operation for field use.</p>
<h4>Connectivity</h4>
<p align="justify">Even though the MEATEST M109R High Resistance Decade looks mechanical, internal resistance standards are switched electronically by relays. This way we the RS232 remote control can be used with the Caliber software or any other automated calibration solution.</p>
<p align="justify">The MEATEST M109R High Resistance Decade is aimed for the calibrating of insulation meters and megohmmeters. It is suitable for calibration laboratories and service centres, where can be used also for testing or setting of high resistance meters. High voltage relays with extremely high insulation resistance are used for switching of resistance components.</p>
<p align="justify">The MEATEST M109R is equipped with indication of input terminal overload. Control is possible manually or remotely via serial interface RS- 232.</p>
<h4 align="justify">MEATEST M109R High Resistance Decade Specification</h4>
<ul>
<li>Range of resistance : 1 MΩ &#8211; 12.221 GΩ</li>
<li>Maximum voltage : 5kV DC between terminals H-L, H-GND, L-GND</li>
<li>Connection : two-terminal, three-terminal (GUARD)</li>
<li>Type of terminals : high voltage terminals with ERTALYTE isolation</li>
<li>Remote control : serial interface</li>
<li>RS-232 Supply : internal accumulator, power line supply adapter 15V (100-240V/50-60 Hz)</li>
<li>Temperature range : 23°C ± 5°C</li>
<li>Relative humidity : 10 &#8211; 50 %</li>
<li>Dimensions : 364 mm x 111 mm x 316 mm</li>
<li>Weight : 4 kg</li>
</ul>
<h4>Item includes:</h4>
<ul>
<li>High resistance decade Model M109R</li>
<li>Power line adapter</li>
<li>Cable RS-232</li>
<li>Software</li>
<li>User’s manual</li>
</ul>
<p>The post <a href="https://rapid-tech.com.au/meatest-m109r-high-resistance-decade/">MEATEST M109R High Resistance Decade</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/meatest-m109r-high-resistance-decade/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>MEATEST M194 High Resistance Decade</title>
		<link>https://rapid-tech.com.au/meatest-m194-high-resistance-decade/</link>
					<comments>https://rapid-tech.com.au/meatest-m194-high-resistance-decade/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Mon, 27 Mar 2017 04:30:54 +0000</pubDate>
				<guid isPermaLink="false">http://rapid-tech.com.au/?post_type=product&#038;p=4857</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-28" src="http://rapid-tech.com.au/wp-content/uploads/2015/12/MEATEST_logo_PL.jpg" alt="MEATEST_logo_PL" width="125" height="28" /></p>
<div class="productDetailText">
<p>The MEATEST M194 High Resistance Decade is a high resistance decade with built-in test signal meter for calibration of high resistance meters up to 6 kV. Based on M6xx Real-Resistance decade series with short function for short current testing.</p>
</div>
<ul>
<li>10 kΩ - 100.0 GΩ, short function</li>
<li>Linear hot-switching up to 6 kVdc limit</li>
<li>Test voltage and current indication</li>
</ul>
<h4><span style="color: #ff0000;">Authorised Australian Distributor</span></h4>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />   <span style="color: #0000ff;"> <span style="text-decoration: underline;"><a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2017/03/M194-Datasheet.pdf" rel="noopener">M194 Datasheet</a></span></span></h5>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline; color: #0000ff;"><a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2017/03/M194-Operation-Manual.pdf" rel="noopener">M194 Operation Manual</a></span></h5>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/meatest-m194-high-resistance-decade/">MEATEST M194 High Resistance Decade</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="justify">The MEATEST M194 High Resistance Decade is designed for calibration of insulation testers, megaohmmeters and resistance ranges of safety testers, HIPOT testers or any other DC high resistance meter with test voltage up to 6 kV. Apart from resistance source in continuous range from 10 kΩ to 100 GΩ, the M194 has built-in multimeter indicating either test voltage in resistance function or mA current in short function for testing of UUT&#8217;s short current.</p>
<p align="justify">The main feature of the MEATEST M194 High Resistance Decade is adjustable high resistance decades in a continuous range from 10 kΩ to 100 GΩ with 4 digit resolution. Designed for maximum operating voltages of up to 6 kVDC this decade is great for calibration of meggers, megaohmmeters and insulation testers. Accuracy from 0.1%.<br />
Full remote control and automated calibration support is a standard for all Meatest instruments. On top of that, M194 comes with 4 interfaces (RS232, USB, LAN and GPIB) to match your system more easily.</p>
<h4>Time-proven design</h4>
<p align="justify">The MEATEST M194 High Resistance Decade is based on the Meatest M6xx series, this programmable decade comes with similar benefits &#8211; large LCD showing relevant parameters including total accuracy, automatically compensated parasitic resistances, easy recalibration procedure and extensive remote control connectivity via RS232, IEEE488, USB and Ethernet.</p>
<h4 align="justify">General data:</h4>
<ul>
<li>Warm up time: 15 minutes</li>
<li>Operating temperatures: 23 ± 10 ºC,</li>
<li>Relative humidity &lt; 70%</li>
<li>Storage temperatures: -10 °C to +50 °C</li>
<li>Reference condition: Ambient temperature 23 ± 2 °C Relative humidity &lt; 50 % for resistance range from 10 GΩ to 100 GΩ</li>
<li>Relative humidity &lt; 70 % for resistance range from 10 kΩ to 10 GΩ</li>
<li>Terminals: instrument terminals diameter 4mm, gold plated</li>
<li>Interface: RS232 (optionally IEEE488, USB, Ethernet)</li>
<li>Dimension: 450 (W) x 430 (D) x 150 (H) mm</li>
<li>Weight 6 kg</li>
<li>Power line: 110/115/120/125 &#8211; 220/230 V – 45/65 Hz</li>
<li>Power consumption: 25 VA</li>
<li>Safety class: I according to EN 1010-1</li>
<li>Isolation resistance between output terminals and housing: &gt; 2 GΩ (at 500V DC)</li>
</ul>
<h4 align="justify">Specifications:</h4>
<table class="vychoziTabulka" style="height: 55px;" width="330">
<tbody>
<tr>
<td>DC resistance</td>
<td>10 kΩ &#8211; 100 GΩ, 6.3 kV max.<br />
± 0.1% / year</td>
</tr>
</tbody>
</table>
<h4>Test Signal Meter</h4>
<table class="vychoziTabulka" style="height: 120px;" width="332">
<tbody>
<tr>
<td>DC voltage</td>
<td>50 V &#8211; 6.3 kV<br />
± 0.5% / year</td>
</tr>
<tr>
<td>DC current</td>
<td>0 &#8211; 10 mA<br />
± 0.2% / year</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>The post <a href="https://rapid-tech.com.au/meatest-m194-high-resistance-decade/">MEATEST M194 High Resistance Decade</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/meatest-m194-high-resistance-decade/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>MEATEST M641 Real-Resistance RTD Simulator</title>
		<link>https://rapid-tech.com.au/meatest-m641-real-resistance-rtd-simulator/</link>
					<comments>https://rapid-tech.com.au/meatest-m641-real-resistance-rtd-simulator/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Wed, 22 Mar 2017 07:02:19 +0000</pubDate>
				<guid isPermaLink="false">http://rapid-tech.com.au/?post_type=product&#038;p=4851</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-28" src="http://rapid-tech.com.au/wp-content/uploads/2015/12/MEATEST_logo_PL.jpg" alt="MEATEST_logo_PL" width="125" height="28" /></p>
<div class="productDetailText">
<p>The Meatest M641 Real-Resistance RTD Simulator is designed for RTD and other resistance based sensors simulation. It's 0.1°C accuracy and 5 W load capacity is suited for industrial use</p>
<p>Operated either manually or via one of four available remote control interfaces these decades are ideal for automated checks at production lines.</p>
</div>
<ul>
<li>Real resistors switched by relays</li>
<li>Custom temperature scales</li>
<li>No residual resistance</li>
<li><strong>0.1°C accuracy</strong></li>
</ul>
<h4><span style="color: #ff0000;">Authorised Australian Distributor</span></h4>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a style="color: #0000ff; text-decoration: underline;" href="http://rapid-tech.com.au/wp-content/uploads/2017/03/M641-Datasheet.pdf" target="_blank" rel="noopener">M641 Datasheet</a></span></span></h5>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a style="color: #0000ff; text-decoration: underline;" href="http://rapid-tech.com.au/wp-content/uploads/2017/03/M641-Operation-Manual.pdf" target="_blank" rel="noopener">M641 Operation Manual</a></span></span></h5>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a style="color: #0000ff; text-decoration: underline;" href="http://rapid-tech.com.au/wp-content/uploads/2017/03/M600-series-Application-Note.pdf" target="_blank" rel="noopener">M600 series Application Note</a></span></span></h5>
<p>The post <a href="https://rapid-tech.com.au/meatest-m641-real-resistance-rtd-simulator/">MEATEST M641 Real-Resistance RTD Simulator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Meatest M641 Real-Resistance RTD Simulator is a precise RTD simulator with range from 16Ω to 400 kΩ. Basic accuracy is 0.003 %. Best resolution at the lowest range is 100µΩ. Decade contains stable foil resistors with low temperature coefficient switched by low thermal voltage relays.</p>
<p>The built-in software of the Meatest M641 Real-Resistance RTD Simulator contains function of RTD temperature sensor simulation with parameters according to IEC (DIN) or US standards, temperature setting in degree of Celsius or Fahrenheit. Instrument can be controlled via RS232, USB, LAN or GPIB interface.</p>
<p>The Meatest M641 Real-Resistance RTD Simulator is sophisticated instrument with its own recalibration procedure. The procedure enables to correct any deviation in resistance without any mechanical adjusting. Decade box is designed for checking parameters of resistance meters, regulators and process meters that use external resistance sensors for non-electric quantity measuring.</p>
<p align="justify">The Meatest M631 and M641 are programmable real-resistance decades with parameters designed specifically for RTD sensors’ simulation and testing of RTD evaluation units like temperature regulators, transducers, etc. The core function is still resistance so you can as well calibrate ohmmeters and other resistance based meters easily. The main difference between M6x1 RTD simulators is combination of accuracy and load capacity. M641 with its 5 W load capacity is suited for industry where M631 with its 0.01°C accuracy and 0.001°C resolution is rather a laboratory reference. Containing some of the most stable (and expensive) foil resistors available, the M631 has temperature coefficient as good as 1 ppm/°C. RTD simulators can be used for AC application as well, see datasheet for typical frequency responses.</p>
<h4>Ease of Use</h4>
<p align="justify">M6xx series was made to make resistance calibration as easy as it gets. Large LCD shows all related parameters including total accuracy. And there is no residual resistance or hidden absolute error so you don’t have to calculate it by yourself, accuracy you see is accuracy you get. And that’s not the only thing that firmware sorts out for you. Would you like the resistance shown in distance or force units? User function will do this for you. Complete recalibration? Ten minutes and off you go.</p>
<h4>Connectivity</h4>
<p align="justify">RTD simulators’ functions can be remotely controlled via RS232, USB, LAN or GPIB interface. This way you can introduce calibration/test stage directly into production line of any resistance based sensor and reduce time required for final quality tests dramatically.</p>
<h4>General Specification:</h4>
<ul>
<li>Maximum voltage: 200 V pk</li>
<li>Maximum current: 500 mA</li>
<li>Total power dissipation: 0.25 W</li>
<li>TC of used resistors:<br />
&lt; 1 ppm/ C (16 Ω … 2 kΩ)<br />
&lt; 5 ppm/ C (2 kΩ … 10 kΩ)<br />
&lt; 50 ppm/ C (10 kΩ … 400 kΩ)</li>
<li>Reaction time: 6 ms</li>
<li>Switching method: Fast / Smooth / Via short / Via open</li>
<li>Terminals: gold plated terminals 4mm</li>
<li>Remote control: RS232 interface (optionally USB, LAN, IEEE488)</li>
<li>Power supply: 115/230 Vac, 50/60 Hz</li>
<li>Reference temperatures: +20°C … +26°C</li>
<li>Working temperatures: +5°C … +40°C</li>
<li>Storage temperatures: -10°C … +50°C</li>
<li>Dimensions: W 390 mm, H 128 mm, D 310 mm</li>
<li>Weight: 5.2 kg</li>
</ul>
<h4>Meatest M641 Soecifications:</h4>
<table class="vychoziTabulka" style="height: 114px;" width="510">
<tbody>
<tr>
<td>Resistance</td>
<td>10 Ω &#8211; 300 kΩ<br />
max dissipation power 5 W<br />
± 200 ppm / year</td>
</tr>
<tr>
<td>Temperature</td>
<td>RTD ± 0.1°C / year, resolution 0.01°C</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<div class="epyt-video-wrapper"><iframe loading="lazy"  id="_ytid_35414"  width="1020" height="574"  data-origwidth="1020" data-origheight="574"  data-relstop="1" src="https://www.youtube.com/embed/QgfXXR1SAVQ?enablejsapi=1&#038;autoplay=0&#038;cc_load_policy=0&#038;cc_lang_pref=&#038;iv_load_policy=1&#038;loop=0&#038;rel=0&#038;fs=1&#038;playsinline=1&#038;autohide=2&#038;theme=dark&#038;color=red&#038;controls=1&#038;disablekb=0&#038;" class="__youtube_prefs__  epyt-is-override  no-lazyload" title="M600 Series Programmable Resistance Decades"  allow="fullscreen; accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen data-no-lazy="1" data-skipgform_ajax_framebjll=""></iframe></div>
<p>&nbsp;</p>
<p>The post <a href="https://rapid-tech.com.au/meatest-m641-real-resistance-rtd-simulator/">MEATEST M641 Real-Resistance RTD Simulator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/meatest-m641-real-resistance-rtd-simulator/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Meatest M631 Real-Resistance RTD Simulator</title>
		<link>https://rapid-tech.com.au/meatest-m631-real-resistance-rtd-simulator/</link>
					<comments>https://rapid-tech.com.au/meatest-m631-real-resistance-rtd-simulator/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 21 Mar 2017 04:10:11 +0000</pubDate>
				<guid isPermaLink="false">http://rapid-tech.com.au/?post_type=product&#038;p=4846</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-28" src="http://rapid-tech.com.au/wp-content/uploads/2015/12/MEATEST_logo_PL.jpg" alt="MEATEST_logo_PL" width="125" height="28" /></p>
<div class="productDetailText">
<p>The Meatest M631 Real-Resistance RTD Simulator is designed for RTD and other resistance based sensors simulation. Operated either manually or via one of four available remote control interfaces. The Meatest M631 with its 0.01°C accuracy and 0.001°C resolution is ideal as  a laboratory reference.</p>
</div>
<ul>
<li>Real resistors switched by relays</li>
<li>Custom temperature scales</li>
<li>No residual resistance</li>
<li><strong>0.01°C accuracy</strong></li>
</ul>
<h4><span style="color: #ff0000;">Authorised Australian Distributor</span></h4>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a style="color: #0000ff; text-decoration: underline;" href="http://rapid-tech.com.au/wp-content/uploads/2017/03/M631-Datasheet.pdf" target="_blank" rel="noopener">M631 Datasheet</a></span></span></h5>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a style="color: #0000ff; text-decoration: underline;" href="http://rapid-tech.com.au/wp-content/uploads/2017/03/M631-Operation-Manual.pdf" target="_blank" rel="noopener">M631 Operation Manual</a></span></span></h5>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a style="color: #0000ff; text-decoration: underline;" href="http://rapid-tech.com.au/wp-content/uploads/2017/03/M600-series-Application-Note.pdf" target="_blank" rel="noopener">M600 series Application Note</a></span></span></h5>
<p>The post <a href="https://rapid-tech.com.au/meatest-m631-real-resistance-rtd-simulator/">Meatest M631 Real-Resistance RTD Simulator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Meatest M631 Real-Resistance RTD Simulator is a precise RTD simulator with range from 16Ω to 400 kΩ. Basic accuracy is 0.003 %. Best resolution at the lowest range is 100µΩ. Decade contains stable foil resistors with low temperature coefficient switched by low thermal voltage relays.</p>
<p>The built-in software of the Meatest M631 Real-Resistance RTD Simulator contains function of RTD temperature sensor simulation with parameters according to IEC (DIN) or US standards, temperature setting in degree of Celsius or Fahrenheit. Instrument can be controlled via RS232, USB, LAN or GPIB interface.</p>
<p>The Meatest M631 Real-Resistance RTD Simulator is sophisticated instrument with its own recalibration procedure. The procedure enables to correct any deviation in resistance without any mechanical adjusting. Decade box is designed for checking parameters of resistance meters, regulators and process meters that use external resistance sensors for non-electric quantity measuring.</p>
<p align="justify">M631 and M641 are programmable real-resistance decades with parameters designed specifically for RTD sensors&#8217; simulation and testing of RTD evaluation units like temperature regulators, transducers, etc. The core function is still resistance so you can as well calibrate ohmmeters and other resistance based meters easily. The main difference between M6x1 RTD simulators is combination of accuracy and load capacity. M641 with its 5 W load capacity is suited for industry where M631 with its 0.01°C accuracy and 0.001°C resolution is rather a laboratory reference. Containing some of the most stable (and expensive) foil resistors available, the M631 has temperature coefficient as good as 1 ppm/°C. RTD simulators can be used for AC application as well, see datasheet for typical frequency responses.</p>
<h4>Ease of Use</h4>
<p align="justify">M6xx series was made to make resistance calibration as easy as it gets. Large LCD shows all related parameters including total accuracy. And there is no residual resistance or hidden absolute error so you don&#8217;t have to calculate it by yourself, accuracy you see is accuracy you get. And that&#8217;s not the only thing that firmware sorts out for you. Would you like the resistance shown in distance or force units? User function will do this for you. Complete recalibration? Ten minutes and off you go.</p>
<h4>Connectivity</h4>
<p align="justify">RTD simulators&#8217; functions can be remotely controlled via RS232, USB, LAN or GPIB interface. This way you can introduce calibration/test stage directly into production line of any resistance based sensor and reduce time required for final quality tests dramatically.</p>
<h4>General Specification:</h4>
<ul>
<li>Maximum voltage: 200 V pk</li>
<li>Maximum current: 500 mA</li>
<li>Total power dissipation: 0.25 W</li>
<li>TC of used resistors:<br />
&lt; 1 ppm/ C (16 Ω … 2 kΩ)<br />
&lt; 5 ppm/ C (2 kΩ … 10 kΩ)<br />
&lt; 50 ppm/ C (10 kΩ … 400 kΩ)</li>
<li>Reaction time: 6 ms</li>
<li>Switching method: Fast / Smooth / Via short / Via open</li>
<li>Terminals: gold plated terminals 4mm</li>
<li>Remote control: RS232 interface (optionally USB, LAN, IEEE488)</li>
<li>Power supply: 115/230 Vac, 50/60 Hz</li>
<li>Reference temperatures: +20°C … +26°C</li>
<li>Working temperatures: +5°C … +40°C</li>
<li>Storage temperatures: -10°C … +50°C</li>
<li>Dimensions: W 390 mm, H 128 mm, D 310 mm</li>
<li>Weight: 5.2 kg</li>
</ul>
<h3>Meatest M631 Specifications:</h3>
<table class="vychoziTabulka" style="height: 117px;" width="481">
<tbody>
<tr>
<td>Resistance</td>
<td>16 Ω &#8211; 400 kΩ<br />
max dissipation power 0.25 W<br />
± 20 ppm / year</td>
</tr>
<tr>
<td>Temperature</td>
<td>RTD ± 0.01°C / year, resolution 0.001°C</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<div class="epyt-video-wrapper"><iframe loading="lazy"  id="_ytid_11125"  width="1020" height="574"  data-origwidth="1020" data-origheight="574"  data-relstop="1" src="https://www.youtube.com/embed/QgfXXR1SAVQ?enablejsapi=1&#038;autoplay=0&#038;cc_load_policy=0&#038;cc_lang_pref=&#038;iv_load_policy=1&#038;loop=0&#038;rel=0&#038;fs=1&#038;playsinline=1&#038;autohide=2&#038;theme=dark&#038;color=red&#038;controls=1&#038;disablekb=0&#038;" class="__youtube_prefs__  epyt-is-override  no-lazyload" title="M600 Series Programmable Resistance Decades"  allow="fullscreen; accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen data-no-lazy="1" data-skipgform_ajax_framebjll=""></iframe></div>
<p>&nbsp;</p>
<p>The post <a href="https://rapid-tech.com.au/meatest-m631-real-resistance-rtd-simulator/">Meatest M631 Real-Resistance RTD Simulator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/meatest-m631-real-resistance-rtd-simulator/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>