<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Loop / PSC Testers Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/loop-psc-testers/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/loop-psc-testers/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Sat, 19 Sep 2026 03:51:55 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.10</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>Loop / PSC Testers Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/loop-psc-testers/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>KYORITSU 6516BT Multi Function Tester with Bluetooth</title>
		<link>https://rapid-tech.com.au/kyoritsu-6516bt-multi-function-tester-with-bluetooth/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 13 Apr 2021 06:11:22 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=16713</guid>

					<description><![CDATA[<p>[block id="fe-004-sc-html"]<br />
<img class="alignnone size-full wp-image-9900" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/Kyoritsu-Premium-Authorised.jpg" alt="" width="250" height="69" /></p>
<p><a target="_blank" href="https://mymeter.com.au/product/kyoritsu-6516bt-multi-function-tester-with-bluetooth/" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="" width="160" height="40" /></a></p>
<p>KEW 6516BT Multi-Function tester has eight test functions in one instrument.</p>
<ul>
<li>Continuity test</li>
<li>Insulation resistance test</li>
<li>Loop impedance test (High current measurement, No trip (ATT) measurement) 4 Prospective short circuit current test (On Loop impedance function)</li>
<li>RCD test</li>
<li>Voltage test</li>
<li>Phase rotation test 8 Earth test</li>
</ul>
<p><img class="alignnone size-full wp-image-17809" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-Download-e1620015214396.png" alt="PDF Download icon" width="51" height="60" /><strong>  <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/10/Kyoritsu-6516-6516BT-Datasheet.pdf" rel="noopener">Kyoritsu 6516-6516BT Datasheet</a></span>     <img class="alignnone size-full wp-image-17809" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-Download-e1620015214396.png" alt="PDF Download icon" width="51" height="60" /> <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/10/Kyoritsu-6516-6516BT-User-Manual.pdf" rel="noopener">Kyoritsu 6516-6516BT User Manual</a><br />
</span></strong></p>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a><strong> <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/10/Kyoritsu-6516-6516BT-GUIDEBOOK.pdf" rel="noopener">Kyoritsu 6516 , 6516BT GUIDEBOOK</a></strong></h4>
<p><strong><span style="text-decoration: underline;"> </span></strong></p>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-6516bt-multi-function-tester-with-bluetooth/">KYORITSU 6516BT Multi Function Tester with Bluetooth</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The KEW 6516 tester incorporates Anti Trip Technology (ATT) which electronically bypasses RCDs when performing loop impedance tests. This saves time and money by not having to take the RCD out of the circuit during testing and is a safer procedure to follow.</p>
<p>With the ATT function enabled, a test of 15mA or less is applied between line &amp; earth. It enables loop impedance measurements without tripping RCDs rated at 30mA and above.</p>
<p>ATT supports measurements using three wires: Line, Earth, and Neutral and also two wires: Line and Earth.</p>
<h4><div class="epyt-video-wrapper"><iframe  id="_ytid_55994"  width="1020" height="574"  data-origwidth="1020" data-origheight="574"  data-relstop="1" src="https://www.youtube.com/embed/_KwfRTtwTys?enablejsapi=1&autoplay=0&cc_load_policy=0&cc_lang_pref=&iv_load_policy=1&loop=0&rel=0&fs=1&playsinline=1&autohide=2&theme=dark&color=red&controls=1&disablekb=0&" class="__youtube_prefs__  no-lazyload" title="MULTI FUNCTION INSTALLATION TESTER KEW 6516/6516BT subtitled in ENGLISH"  allow="fullscreen; accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen data-no-lazy="1" data-skipgform_ajax_framebjll=""></iframe></div></h4>
<h3>Kyoritsu 6516 Multi Function Tester Features</h3>
<table style="height: 493px;" width="701">
<tbody>
<tr>
<td width="64"><strong><span style="font-size: 90%;">DISPLAY </span></strong></td>
<td width="571"><span style="font-size: 90%;">・Color LCD 3.5 inches dot matrix.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">ATT </span></strong></td>
<td><span style="font-size: 90%;">・Anti-Trip Technology (with 2 &amp; 3 wire) for no trip LOOP L-PE testing on all RCDs.</span></td>
</tr>
<tr>
<td></td>
<td><span style="font-size: 90%;">・With 2 wire only, very useful in case of no Neutral (i.e. 3-phase motor lines).</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">LOOP </span></strong></td>
<td><span style="font-size: 90%;">・High test current range of 2Ω with 0.001Ω resolution.</span></td>
</tr>
<tr>
<td></td>
<td><span style="font-size: 90%;">・Zs Limit compares the values required by Electrical Installations Standard with measured results.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">RCD  </span></strong></td>
<td><span style="font-size: 90%;">・Type AC, A, F, B(General &amp; Selective), EV and Variable RCDs.</span></td>
</tr>
<tr>
<td></td>
<td><span style="font-size: 90%;">・Single and Auto test, Ramp test and Contact voltage.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">EARTH</span></strong></td>
<td><span style="font-size: 90%;">・Earth resistance test 2 and 3 wires with all accessories included.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">INSULATION </span></strong></td>
<td><span style="font-size: 90%;">・Resistance test 100, 250, 500 &amp; 1000V with auto discharge voltage.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">CONTINUITY</span></strong></td>
<td><span style="font-size: 90%;">・Continuity test at 200mA or 15mA with selectable buzzer for fast judgment.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">PHASE ROTATION </span></strong></td>
<td><span style="font-size: 90%;">・On 3-phase lines with clear indication of the sequence on the display.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">VOLTS </span></strong></td>
<td><span style="font-size: 90%;">・TRMS Voltage measurements 2-600V, Mains Frequency.</span></td>
</tr>
<tr>
<td><span style="font-size: 90%;"><strong>HELP</strong>  </span></td>
<td><span style="font-size: 90%;">・Display shows how to connect the instrument according to the function selected.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">SPD  </span></strong></td>
<td><span style="font-size: 90%;"> ・Surge Protection Device test, for SPD that uses varistor.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">PAT </span></strong></td>
<td><span style="font-size: 90%;">・Portable Appliance Tester function, for Insulation &amp; Protective conductor resistance test</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">BLUETOOTH</span></strong></td>
<td><span style="font-size: 90%;">・Communication by &#8220;KEW CONNECT&#8221;</span></td>
</tr>
<tr>
<td><span style="font-size: 90%;"><strong>SAFETY </strong>  </span></td>
<td><span style="font-size: 90%;">・IEC 61010-1 CAT IV 300 V, CAT III 600 V. IEC 61557-1,2,3,4,5,6,</span></td>
</tr>
</tbody>
</table>
<h4><a></a>Bluetooth communication</h4>
<p>KEW 6516BT has a Bluetooth communication function and can exchange data with Android/ iOS tablet devices.</p>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2021/04/6516BT_apk3.png"><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-17704" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/6516BT_apk3.png" alt="516BT_apk3" width="331" height="244" srcset="https://rapid-tech.com.au/wp-content/uploads/2021/04/6516BT_apk3.png 331w, https://rapid-tech.com.au/wp-content/uploads/2021/04/6516BT_apk3-300x221.png 300w" sizes="(max-width: 331px) 100vw, 331px" /></a><a href="https://rapid-tech.com.au/wp-content/uploads/2021/04/6516BT_apk2.png"><img decoding="async" class="alignnone size-full wp-image-17703" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/6516BT_apk2.png" alt="6516BT apk2" width="349" height="244" srcset="https://rapid-tech.com.au/wp-content/uploads/2021/04/6516BT_apk2.png 349w, https://rapid-tech.com.au/wp-content/uploads/2021/04/6516BT_apk2-300x210.png 300w" sizes="(max-width: 349px) 100vw, 349px" /></a></p>
<p>Before starting to use this function, download the special application &#8220;KEW Smart *&#8221; via the internet.</p>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2021/04/KEW-Smart-ast.png"><img loading="lazy" decoding="async" class="alignnone wp-image-17706" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/KEW-Smart-ast.png" alt="KEW Smart" width="143" height="143" srcset="https://rapid-tech.com.au/wp-content/uploads/2021/04/KEW-Smart-ast.png 266w, https://rapid-tech.com.au/wp-content/uploads/2021/04/KEW-Smart-ast-100x100.png 100w, https://rapid-tech.com.au/wp-content/uploads/2021/04/KEW-Smart-ast-150x150.png 150w" sizes="auto, (max-width: 143px) 100vw, 143px" /></a></p>
<h4 class="tm4">Large LCD &amp; HELP function</h4>
<ul>
<li>All the test data is shown in one large colored screen.</li>
<li>HELP function will show how to connect the instrument according to the function selected</li>
</ul>
<p>&nbsp;</p>
<h4 class="tm4">Operation in 3 simple steps &amp; Hands free testing</h4>
<ol>
<li>Set the rotary dial to your testing range.</li>
<li>Connect the instrument to the installation under test.</li>
<li>Press the test button.(By remote probe or using the Lockdown function of the test button.)</li>
</ol>
<p>&nbsp;</p>
<h4 class="tm4">Anti-Trip Technology (with 2 &amp; 3 wire)</h4>
<p>For no trip LOOP L-PE testing on all RCDs.<br />
With 3 wire (L, N, PE), to get the best accuracy readings.<br />
With 2 wire only, very useful in case of no Neutral (i.e. 3-phase motor lines).</p>
<p>Loop Impedance 0.001 resolution</p>
<p>High test current range of 2Ω with 0.001Ω resolution.</p>
<p>Zs/Ra Limit</p>
<p>Zs Limit compares the values required by Electrical Installations Standard with measured results.</p>
<p>The verification of safety requirement on an electrical installation is simplified by using Zs/Ra Limit function. This function will automatically check if the measured loop impedance for TN (or earth loop for TT) is low enough to trip (disconnect) the MCB / Fuse / RCD giving the result of PASS or FAIL on the display.</p>
<!-- Field Efficient CTA — rotating banner (pure CSS, no JavaScript). Paste the whole block (style + section).
     Only the headline + subline rotate; stat, chips and button stay put. Edit the six .fea-slide blocks to change copy. -->
<style>
  #fea-rot{background:#0E1116;border-radius:16px;padding:34px 34px 30px;color:#fff;font-family:Inter,-apple-system,'Segoe UI',Roboto,Arial,sans-serif;margin:32px 0;}
  #fea-rot .fea-cycle{display:grid;}
  #fea-rot .fea-slide{grid-area:1/1;opacity:0;animation:feaRot 30s infinite;}
  #fea-rot .fea-slide:nth-child(1){animation-delay:0s}
  #fea-rot .fea-slide:nth-child(2){animation-delay:-5s}
  #fea-rot .fea-slide:nth-child(3){animation-delay:-10s}
  #fea-rot .fea-slide:nth-child(4){animation-delay:-15s}
  #fea-rot .fea-slide:nth-child(5){animation-delay:-20s}
  #fea-rot .fea-slide:nth-child(6){animation-delay:-25s}
  #fea-rot .fea-h{font-size:28px;line-height:1.2;margin:0 0 10px;font-weight:700;color:#fff;}
  #fea-rot .fea-s{color:#B7BEC9;font-size:15px;margin:0;}
  #fea-rot .fea-q{color:#3D86FF;}
  #fea-rot:hover .fea-slide{animation-play-state:paused;}
  @keyframes feaRot{0%{opacity:1}13%{opacity:1}17%{opacity:0}96%{opacity:0}100%{opacity:1}}
  @media (prefers-reduced-motion:reduce){#fea-rot .fea-slide{animation:none;opacity:0}#fea-rot .fea-slide:nth-child(1){opacity:1}}
</style>
<section id="fea-rot">
  <div style="font-size:12px;letter-spacing:.1em;text-transform:uppercase;color:#3D86FF;font-weight:600;margin-bottom:14px;">
    <span style="display:inline-block;width:20px;height:20px;border-radius:5px;background:#0066FF;color:#fff;font-weight:800;font-size:11px;text-align:center;line-height:20px;vertical-align:middle;margin-right:8px;">FE</span>
    Field Efficient &middot; reporting software
  </div>
  <div style="display:flex;justify-content:space-between;gap:24px;flex-wrap:wrap;align-items:flex-start;">
    <div style="flex:1 1 300px;min-width:0;">
      <div class="fea-cycle">
        <div class="fea-slide" style="opacity:1"><h3 class="fea-h">Your meter does the testing. <span class="fea-q">Field Efficient does the paperwork.</span></h3><p class="fea-s">Read it off the tester, snap the display, say the readings or drop in the export — from any brand you buy here — and walk off site with a branded, compliant report.</p></div>
        <div class="fea-slide" style="opacity:0"><h3 class="fea-h">Read it straight off the tester. <span class="fea-q">No re-keying.</span></h3><p class="fea-s">Pair your phone with a supported tester over Bluetooth or Wi-Fi — the value on the meter is the value on the report.</p></div>
        <div class="fea-slide" style="opacity:0"><h3 class="fea-h">Any meter. Any brand. <span class="fea-q">One report.</span></h3><p class="fea-s">Fluke, Kyoritsu, Megger, Metrel, Seaward — whatever is in your kit, Field Efficient turns its output into a client-ready report.</p></div>
        <div class="fea-slide" style="opacity:0"><h3 class="fea-h">Off the tools should not mean <span class="fea-q">on the laptop.</span></h3><p class="fea-s">Capture your tests on site and the report is finished before you have packed the ute.</p></div>
        <div class="fea-slide" style="opacity:0"><h3 class="fea-h">A fail never leaves site <span class="fea-q">unnoticed.</span></h3><p class="fea-s">Every reading is checked against AS/NZS 3017, 3760, 5033 &amp; 4777 the moment you enter it — fix it at the board, not from the office.</p></div>
        <div class="fea-slide" style="opacity:0"><h3 class="fea-h">One app. <span class="fea-q">Every discipline.</span></h3><p class="fea-s">Electrical testing, test &amp; tag, solar, inverter and EV charger work — captured, checked and reported in one place. One subscription instead of three point apps.</p></div>
      </div>
    </div>
    <div style="text-align:right;min-width:150px;">
      <span style="font-family:Menlo,Consolas,monospace;color:#FF6B5E;font-size:20px;text-decoration:line-through;">2 hrs</span>
      <span style="font-family:Menlo,Consolas,monospace;color:#34C759;font-size:34px;font-weight:600;display:block;line-height:1.1;">5 min</span>
      <span style="color:#8A919C;font-size:12px;">per job, on admin</span>
    </div>
  </div>
  <div style="display:flex;gap:10px;flex-wrap:wrap;margin:22px 0;">
    <span style="border:1px solid #2A3140;border-radius:999px;padding:7px 14px;font-size:13.5px;color:#DDE2E9;"><span style="color:#34C759;font-weight:700;">&#10003;</span> Every reading checked live against AS/NZS 3017, 3760, 5033 &amp; 4777</span>
    <span style="border:1px solid #2A3140;border-radius:999px;padding:7px 14px;font-size:13.5px;color:#DDE2E9;"><span style="color:#34C759;font-weight:700;">&#10003;</span> Reads results straight off the tester</span>
    <span style="border:1px solid #2A3140;border-radius:999px;padding:7px 14px;font-size:13.5px;color:#DDE2E9;"><span style="color:#34C759;font-weight:700;">&#10003;</span> Electrical, test &amp; tag, solar &amp; EV — one app, one report</span>
  </div>
  <div style="display:flex;align-items:center;gap:18px;flex-wrap:wrap;">
    <a href="https://fieldefficient.com.au/signup?ref=mymeter&utm_source=mymeter&utm_medium=referral&utm_campaign=cta_rotator" style="background:#0066FF;color:#fff;border-radius:999px;padding:13px 26px;font-weight:600;font-size:15px;text-decoration:none;display:inline-block;">Start your free 14-day trial</a>
    <span style="color:#8A919C;font-size:13px;">Pays for itself in one job</span>
    <a href="https://fieldefficient.com.au/?ref=mymeter" style="color:#3D86FF;font-size:14px;text-decoration:none;">See how it works &rarr;</a>
  </div>
  <p style="color:#6E7683;font-size:12.5px;margin:14px 0 0;">No credit card required &middot; cancel anytime &middot; built in Australia for test &amp; measurement pros &middot; data hosted in Sydney</p>
</section>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-6516bt-multi-function-tester-with-bluetooth/">KYORITSU 6516BT Multi Function Tester with Bluetooth</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Kyoritsu 6516 Multi Function Tester</title>
		<link>https://rapid-tech.com.au/kyoritsu-6516-multi-function-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 04:12:43 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=16712</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2019/02/Kyoritsu-Premium-Authorised.jpg"><img class="alignnone size-full wp-image-9900" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/Kyoritsu-Premium-Authorised.jpg" alt="" width="250" height="69" /></a></p>
<p>The KEW 6516/ KEW 6516BT Multi-Function tester has eight test functions in one instrument.</p>
<ul>
<li>Continuity test</li>
<li>Insulation resistance test</li>
<li>Loop impedance test (High current measurement, No trip (ATT) measurement) 4 Prospective short circuit current test (On Loop impedance function)</li>
<li>RCD test</li>
<li>Voltage test</li>
<li>Phase rotation test 8 Earth test</li>
</ul>
<p>The KEW 6516 tester incorporates Anti Trip Technology (ATT) which electronically bypasses RCDs when performing loop impedance tests. This saves time and money by not having to take the RCD out of the circuit during testing and is a safer procedure to follow.</p>
<p>With the ATT function enabled, a test of 15mA or less is applied between line &#38; earth. It enables loop impedance measurements without tripping RCDs rated at 30mA and above.</p>
<p>ATT supports measurements using three wires: Line, Earth, and Neutral and also two wires: Line and Earth.</p>
<h4><strong>Also available is the Kyoritsu 6516BT with Bluetooth</strong></h4>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><strong><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/10/Kyoritsu-6516-6516BT-Datasheet.pdf" rel="noopener">Kyoritsu 6516-6516BT Datasheet</a></strong></span></h4>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><strong><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/10/Kyoritsu-6516-6516BT-User-Manual.pdf" rel="noopener">Kyoritsu 6516-6516BT User Manual</a></strong></span></h4>
<p>&#160;</p>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a><strong> <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/10/Kyoritsu-6516-6516BT-GUIDEBOOK.pdf" rel="noopener">Kyoritsu 6516 , 6516BT GUIDEBOOK</a></strong></h4>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-6516-multi-function-tester/">Kyoritsu 6516 Multi Function Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Kyoritsu 6516 Multi Function Tester Features</h3>
<table style="height: 493px;" width="701">
<tbody>
<tr>
<td width="64"><strong><span style="font-size: 90%;">DISPLAY </span></strong></td>
<td width="571"><span style="font-size: 90%;">・Color LCD 3.5 inches dot matrix.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">ATT </span></strong></td>
<td><span style="font-size: 90%;">・Anti-Trip Technology (with 2 &amp; 3 wire) for no trip LOOP L-PE testing on all RCDs.</span></td>
</tr>
<tr>
<td></td>
<td><span style="font-size: 90%;">・With 2 wire only, very useful in case of no Neutral (i.e. 3-phase motor lines).</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">LOOP </span></strong></td>
<td><span style="font-size: 90%;">・High test current range of 2Ω with 0.001Ω resolution.</span></td>
</tr>
<tr>
<td></td>
<td><span style="font-size: 90%;">・Zs Limit compares the values required by Electrical Installations Standard with measured results.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">RCD  </span></strong></td>
<td><span style="font-size: 90%;">・Type AC, A, F, B(General &amp; Selective), EV and Variable RCDs.</span></td>
</tr>
<tr>
<td></td>
<td><span style="font-size: 90%;">・Single and Auto test, Ramp test and Contact voltage.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">EARTH</span></strong></td>
<td><span style="font-size: 90%;">・Earth resistance test 2 and 3 wires with all accessories included.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">INSULATION </span></strong></td>
<td><span style="font-size: 90%;">・Resistance test 100, 250, 500 &amp; 1000V with auto discharge voltage.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">CONTINUITY</span></strong></td>
<td><span style="font-size: 90%;">・Continuity test at 200mA or 15mA with selectable buzzer for fast judgment.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">PHASE ROTATION </span></strong></td>
<td><span style="font-size: 90%;">・On 3-phase lines with clear indication of the sequence on the display.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">VOLTS </span></strong></td>
<td><span style="font-size: 90%;">・TRMS Voltage measurements 2-600V, Mains Frequency.</span></td>
</tr>
<tr>
<td><span style="font-size: 90%;"><strong>HELP</strong>  </span></td>
<td><span style="font-size: 90%;">・Display shows how to connect the instrument according to the function selected.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">SPD  </span></strong></td>
<td><span style="font-size: 90%;"> ・Surge Protection Device test, for SPD that uses varistor.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">PAT </span></strong></td>
<td><span style="font-size: 90%;">・Portable Appliance Tester function, for Insulation &amp; Protective conductor resistance test</span></td>
</tr>
<tr>
<td><span style="font-size: 90%;"><strong>SAFETY </strong>  </span></td>
<td><span style="font-size: 90%;">・IEC 61010-1 CAT IV 300 V, CAT III 600 V. IEC 61557-1,2,3,4,5,6,</span></td>
</tr>
</tbody>
</table>
<h4><a></a>Bluetooth communication</h4>
<p>KEW 6516BT has a Bluetooth communication function and can exchange data with Android/ iOS tablet devices.</p>
<p>Before starting to use this function, download the special application &#8220;KEW Smart *&#8221; via the internet.</p>
<h4 class="tm4">Large LCD &amp; HELP function</h4>
<ul>
<li>All the test data is shown in one large colored screen.</li>
<li>HELP function will show how to connect the instrument according to the function selected</li>
</ul>
<div class="row"  id="row-43748988">

	<div id="col-1349679542" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<img loading="lazy" decoding="async" class="aligncenter" src="https://www.kew-ltd.co.jp/files/en/img/6516_HELP.png" alt="" width="350" height="260" /></p>
		</div>
					</div>

	

	<div id="col-79168674" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<img loading="lazy" decoding="async" class="aligncenter" src="https://www.kew-ltd.co.jp/files/en/img/6516%20Large%20LCD.png" alt="" width="261" height="256" /></p>
		</div>
					</div>

	
</div>
<h4 class="tm4">Operation in 3 simple steps &amp; Hands free testing</h4>
<ol>
<li>Set the rotary dial to your testing range.</li>
<li>Connect the instrument to the installation under test.</li>
<li>Press the test button.(By remote probe or using the Lockdown function of the test button.)</li>
</ol>
<div class="row"  id="row-1309343304">

	<div id="col-1204138725" class="col medium-1/1 large-12"  >
				<div class="col-inner"  >
			
			
<img loading="lazy" decoding="async" class="aligncenter" src="https://www.kew-ltd.co.jp/files/en/img/6516_123step.png" width="600" height="261" /></p>
		</div>
					</div>

	
</div>
<p>&nbsp;</p>
<h4 class="tm4">Anti-Trip Technology (with 2 &amp; 3 wire)</h4>
<p>For no trip LOOP L-PE testing on all RCDs.<br />
With 3 wire (L, N, PE), to get the best accuracy readings.<br />
With 2 wire only, very useful in case of no Neutral (i.e. 3-phase motor lines).</p>
<p>Loop Impedance 0.001 resolution</p>
<p>High test current range of 2Ω with 0.001Ω resolution.</p>
<p>Zs/Ra Limit</p>
<p>Zs Limit compares the values required by Electrical Installations Standard with measured results.</p>
<p>The verification of safety requirement on an electrical installation is simplified by using Zs/Ra Limit function. This function will automatically check if the measured loop impedance for TN (or earth loop for TT) is low enough to trip (disconnect) the MCB / Fuse / RCD giving the result of PASS or FAIL on the display.</p>
<div class="row"  id="row-923618451">

	<div id="col-191222763" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<img loading="lazy" decoding="async" class="alignleft" src="https://www.kew-ltd.co.jp/files/en/img/6516_0001.png" width="250" height="186" align="right" /></p>
		</div>
					</div>

	

	<div id="col-1685033986" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<img loading="lazy" decoding="async" class="alignright" src="https://www.kew-ltd.co.jp/files/en/img/6516_Zs%20table.png" width="260" height="171" align="right" /></p>
		</div>
					</div>

	
</div>
<p>&nbsp;</p>
<h4 class="tm4">SPD test</h4>
<p>SPD (Surge Protection Device) which contains varistor can be tested measuring the tripping voltage without damage it.<br />
<div class="row"  id="row-426711221">

	<div id="col-1369043572" class="col medium-1/1 large-12"  >
				<div class="col-inner"  >
			
			
<img loading="lazy" decoding="async" class="alignleft" src="https://www.kew-ltd.co.jp/files/en/img/6516_SPD.png" width="250" height="174" align="right" /></p>
		</div>
					</div>

	
</div>
<h5></h5>
<h5></h5>
<p>&nbsp;</p>
<h5></h5>
<h5></h5>
<h4 class="tm4">PAT test</h4>
<p>PAT test (PAT = Portable Appliance Tester) It is possible to check the insulation resistance and earth bond continuity of portable appliances for class I and II.</p>
<div class="row"  id="row-1312766930">

	<div id="col-1873701234" class="col medium-1/1 large-12"  >
				<div class="col-inner"  >
			
			
<img loading="lazy" decoding="async" class="alignleft" src="https://www.kew-ltd.co.jp/files/en/img/6516_PAT.1png.png" width="300" height="253" align="right" /></p>
		</div>
					</div>

	
</div>
<p>&nbsp;</p>
<h4 class="tm4">Connectivity</h4>
<p><strong>Use the PC application KEW Report to improve work efficiency.</strong></p>
<p>KEW 6516 can download the test data by connecting the USB adaptor (Model 8212-USB) and then print complete Test Reports by a PC.<div class="row"  id="row-146588981">

	<div id="col-983694702" class="col medium-1/1 large-12"  >
				<div class="col-inner"  >
			
			
<p><img loading="lazy" decoding="async" class="alignleft" src="https://www.kew-ltd.co.jp/files/en/img/6516_PC.png" width="300" height="216" align="right" /></p>
<p><img loading="lazy" decoding="async" src="https://www.kew-ltd.co.jp/files/en/img/6516BT_PC1.png" width="350" height="134" /></p>
		</div>
					</div>

	
</div>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-6516-multi-function-tester/">Kyoritsu 6516 Multi Function Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Kyoritsu 6016 Multi Function Electrical Tester</title>
		<link>https://rapid-tech.com.au/kyoritsu-6016-multi-function-electrical-testers/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Fri, 09 Mar 2018 00:57:53 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=6324</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-9900" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/Kyoritsu-Premium-Authorised.jpg" alt="" width="250" height="69" /></p>
<p><a target="_blank" href="https://mymeter.com.au/product/kyoritsu-6016-multi-function-electrical-tester/" rel="noopener noreferrer"><img class="aligncenter wp-image-16672 size-full" src="https://rapid-tech.com.au/wp-content/uploads/2020/01/Buy-Now-Flir-Direct-sm.jpg" alt="" width="200" height="49" /></a></p>
<h3 style="text-align: center;"><strong>Kyoritsu 6016 Multi Function Tester Features:</strong></h3>
<p>&#160;</p>
<p style="text-align: center;"><a href="https://rapid-tech.com.au/wp-content/uploads/2018/03/Kyoritsu-6016-10-1.gif"><img class="alignnone size-full wp-image-6325" src="https://rapid-tech.com.au/wp-content/uploads/2018/03/Kyoritsu-6016-10-1.gif" alt="" width="200" height="301" /></a></p>
<ul>
<li><strong>10 in 1 Tester</strong> - Continuity, Insulation, Loop, PSC, PFC, RCD, Earth, Phase Rotation, Volts and Frequency Testing</li>
<li>Advanced Anti-Trip Technology (ATT) for avoiding RCDs trip during loop testing.</li>
<li>A single rotary dial to make selection of test and measurement functions</li>
<li>Slim remote probe with test button as well as a lockdown option on the instrument for the most convenient hands free testing.</li>
<li>Safety test leads have an overmould for maximum grip and are extremely robust.</li>
<li>PC software for downloading and interpreting of data and interface cable are included.</li>
<li>Soft carry case included to store instrument and all the test leads.</li>
</ul>
<p>&#160;</p>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="color: #0000ff;"><a href="https://rapid-tech.com.au/wp-content/uploads/2018/03/Kyoritsu-6016-Datasheet.pdf">Kyoritsu 6016 Datasheet</a></span></h3>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-6016-multi-function-electrical-testers/">Kyoritsu 6016 Multi Function Electrical Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Kyoritsu 6016 Multi Function Electrical Tester Functions:</h3>
<p style="text-align: center;"><a href="https://rapid-tech.com.au/wp-content/uploads/2018/03/Kyoritsu-6016-10-Buttons.jpg"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-6330" src="https://rapid-tech.com.au/wp-content/uploads/2018/03/Kyoritsu-6016-10-Buttons.jpg" alt="" width="819" height="109" srcset="https://rapid-tech.com.au/wp-content/uploads/2018/03/Kyoritsu-6016-10-Buttons.jpg 819w, https://rapid-tech.com.au/wp-content/uploads/2018/03/Kyoritsu-6016-10-Buttons-300x40.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2018/03/Kyoritsu-6016-10-Buttons-600x80.jpg 600w, https://rapid-tech.com.au/wp-content/uploads/2018/03/Kyoritsu-6016-10-Buttons-768x102.jpg 768w" sizes="auto, (max-width: 819px) 100vw, 819px" /></a></p>
<p><strong>Continuity Measurement </strong><br />
With the Kyoritsu 6016 Multi Function Electrical Tester continuity testing can be carried out by use of the test button lockdown feature. A selectable buzzer gives instantaneous indication of continuity. Null facility eliminates the test lead resistance from the results, the nulled value is retained even if the instrument is switched off. Live circuit warnings are given by a flashing LED, buzzer and indication on the display.</p>
<p><strong>Insulation Measurement </strong><br />
The Kyoritsu 6016 Multi Function Electrical Tester has three selectable test voltages <strong>250V, 500V and 1000V.</strong> An auto-discharge function ensures that circuits are not hazardous after testing. A red LED gives warning of high voltage output during testing and discharging of the circuit. In case of connecting to a live circuit, a live circuit warning is given by flashing LED, buzzer and indication on the display.</p>
<p><strong>Loop Impedance Measurement</strong><br />
The Kyoritsu 6016 Multi Function Electrical TesterA patented (ATT) low current loop impedance test enables high accuracy loop measurements and quick testing without tripping RCD&#8217;s.<br />
A high current alternative is selectable for even higher accuracy and instantaneous results. The subsequent test will default to the low current test, this saves any inadvertent tripping of the RCD. The KEW 6016 allows also for phase to phase loop tests.</p>
<p><strong>PSC / PFC Measurement </strong><br />
The Prospective Short Circuit Current (PSC) and Prospective Fault Current (PFC) are automatically calculated and shown on the display. As loop testing, the function has low and high test current options with the default to low current to avoid inadvertent tripping of RCDs.</p>
<p><strong>RCD Measurement </strong><br />
The KEW 6016 has a comprehensive RCD test feature for RCD type AC (Alternative Currents), RCD type A (Pulsating Direct Currents), General and Selective (delayed).<br />
Measures at 1/2x, 1x, 5x of nominal RCD current. It also has Ramp Test and Auto test where all results are shown on one screen. Touch voltage limit can be selected for 25V or 50V depending on application</p>
<p><strong>Earth Measurement </strong><br />
Using the classical Volt-Amper method with two auxiliary earth spikes and without external power source. All test leads and spikes are supplied as standard accessories.</p>
<p><strong>Phase rotation </strong><br />
KEW 6016 can check the phase rotation of three phase lines with clear indication of the sequence on the display.</p>
<p><strong>Voltage Measurement </strong><br />
In addiction to the voltage measurement, this function gives also the Frequency of the voltage under test.</p>
<h3>Kyoritsu 6016 Multi Function Electrical Tester Specifications:</h3>
<div class="editor">
<div class="tableScroller">
<table>
<tbody>
<tr>
<th colspan="8"><span style="color: #ed1c24;">Continuity</span></th>
</tr>
<tr>
<th>Range</th>
<td colspan="7">20/200/2000Ω (Auto-ranging)</td>
</tr>
<tr>
<th> Open circuit<br />
voltage (DC)</th>
<td colspan="7">5V±20% (*1)</td>
</tr>
<tr>
<th>Short circuit<br />
current</th>
<td colspan="7">Greater than 200mA</td>
</tr>
<tr>
<th>Accuracy</th>
<td colspan="7">±0.1Ω (0 &#8211; 0.19Ω)<br />
±2%rdg+8dgt (0.2 &#8211; 2000Ω)</td>
</tr>
<tr>
<th colspan="8"><span style="color: #ed1c24;">Insulation Resistance</span></th>
</tr>
<tr>
<th>Range</th>
<td colspan="4">20/200MΩ<br />
(Auto-ranging)</td>
<td colspan="3">20/200/2000MΩ (Auto-ranging)</td>
</tr>
<tr>
<th>Open circuit<br />
voltage (DC)</th>
<td colspan="4">250V+25% -0%</td>
<td>500V+25% -0%</td>
<td colspan="2">1000V+20% -0%</td>
</tr>
<tr>
<th>Rated current</th>
<td colspan="4">1mA or greater<br />
@ 250kΩ</td>
<td>1mA or greater<br />
@ 500kΩ</td>
<td colspan="2">1mA or greater<br />
@ 1MΩ</td>
</tr>
<tr>
<th>Accuracy</th>
<td colspan="4">±2%rdg+6dgt<br />
(0 &#8211; 19.99MΩ)<br />
±5%rdg+6dgt<br />
(20 &#8211; 200MΩ)</td>
<td colspan="3">±2%rdg+6dgt (0 &#8211; 199.9MΩ)<br />
±5%rdg+6dgt (200 &#8211; 2000MΩ)</td>
</tr>
<tr>
<th colspan="8"><span style="color: #ed1c24;">Loop Impedance</span></th>
</tr>
<tr>
<th>Function</th>
<td colspan="4">L-PE</td>
<td>L-PE (ATT)</td>
<td colspan="2">L-N / L-L</td>
</tr>
<tr>
<th>Rated Voltage</th>
<td colspan="5">100 &#8211; 260V 50/60Hz</td>
<td colspan="2">L-N: 100 &#8211; 300V<br />
L-L: 300 &#8211; 500V<br />
50/60Hz</td>
</tr>
<tr>
<th>Nominal Test<br />
Current at 0Ω<br />
External Loop:<br />
Magnitude/<br />
Duration (*2)</th>
<td colspan="4">20Ω: 6A/20ms<br />
200Ω: 2A/20ms<br />
2000Ω: 15mA/500ms</td>
<td>L-N: 6A/60ms<br />
N-PE: 10mA/approx. 5s</td>
<td colspan="2">20Ω: 6A/20ms</td>
</tr>
<tr>
<th>Range</th>
<td colspan="4">20/200/2000Ω<br />
(Auto-ranging)</td>
<td>20/200/2000Ω<br />
(Auto-ranging)<br />
(L-N &lt; 20Ω)</td>
<td colspan="2">20Ω</td>
</tr>
<tr>
<th>Accuracy</th>
<td colspan="4">±3%rdg+4dgt(*3)<br />
±3%rdg+8dgt(*4)</td>
<td>±3%rdg+6dgt (*3)<br />
±3%rdg+8dgt(*4)</td>
<td colspan="2">±3%rdg+4dgt (*3)<br />
±3%rdg+8dgt(*4)</td>
</tr>
<tr>
<th colspan="8"><span style="color: #ed1c24;">PSC (L-N / L-L) / PFC (L-PE)</span></th>
</tr>
<tr>
<th>Function</th>
<td colspan="4">PSC</td>
<td>PFC</td>
<td colspan="2">PFC (ATT)</td>
</tr>
<tr>
<th>Rated Voltage</th>
<td colspan="4">100 &#8211; 500V 50/60Hz</td>
<td>100 &#8211; 260V 50/60Hz</td>
<td colspan="2"></td>
</tr>
<tr>
<th>Nominal Test<br />
Current at 0Ω<br />
External Loop:<br />
Magnitude/<br />
Duration (*5)</th>
<td colspan="4">6A/20ms</td>
<td>6A/20ms<br />
2A/20ms<br />
15mA/500ms</td>
<td colspan="2">L-N: 6A/60ms<br />
N-PE: 10mA/approx. 5s</td>
</tr>
<tr>
<th> Range</th>
<td colspan="7">2000A/20kA Auto-Ranging</td>
</tr>
<tr>
<th>Accuracy</th>
<td colspan="7">PSC / PFC accuracy is derived from measured loop impedance<br />
specification and measured voltage specification</td>
</tr>
<tr>
<th colspan="8"><span style="color: #ed1c24;">RCD</span></th>
</tr>
<tr>
<th>Function</th>
<td colspan="2">X1/2</td>
<td colspan="2">X1</td>
<td>X5</td>
<td>Ramp</td>
<td>Auto</td>
</tr>
<tr>
<th>Trip current<br />
setting</th>
<td colspan="4">10/30/100/300/<br />
500/1000mA</td>
<td>10/30/<br />
100mA</td>
<td>10/30/<br />
100/300/<br />
500mA</td>
<td rowspan="5">Depending on the<br />
accuracy at each<br />
function.<br />
Measurement sequence:<br />
X1/2 0°→X1/2 180°<br />
→X1 0°→X1 180°<br />
→X5 0°→X5 180°<br />
Measurements with<br />
x5 are not carried out<br />
for RCDs with<br />
nominal current of<br />
100mA or more.</td>
</tr>
<tr>
<th>Trip current<br />
Duration</th>
<td colspan="2">2000ms</td>
<td colspan="2">G: 550ms<br />
S: 1000ms</td>
<td>410ms</td>
<td>Goes up by<br />
10% from<br />
20% to<br />
110%<br />
G:300ms/<br />
S:500ms<br />
X10 times</td>
</tr>
<tr>
<th>Rated Voltage</th>
<td colspan="6">230V+10%-15% 50/60Hz</td>
</tr>
<tr>
<th rowspan="2">Accuracy</th>
<td colspan="2">AC Type:<br />
-8% &#8211; -2%<br />
A Type:<br />
-10% &#8211; 0%</td>
<td colspan="3">AC Type: +2% &#8211; +8%<br />
A Type: 0% &#8211; +10%</td>
<td>AC Type: ±4%<br />
A Type: ±10%</td>
</tr>
<tr>
<td colspan="6">Trip time: ±1%rdg+3dgt</td>
</tr>
<tr>
<th colspan="9"><span style="color: #ed1c24;">RCD (Uc)</span></th>
</tr>
<tr>
<th>Function</th>
<td colspan="8">UC</td>
</tr>
<tr>
<th>Rated Voltage</th>
<td colspan="8">230V+10% &#8211; 15% 50/60Hz</td>
</tr>
<tr>
<th>Range</th>
<td colspan="8">100.0V</td>
</tr>
<tr>
<th>Test current</th>
<td colspan="8">≤ 1/2IΔn (max150mA)</td>
</tr>
<tr>
<th>Accuracy</th>
<td colspan="8">+5% &#8211; +15%rdg, ±8dgt</td>
</tr>
<tr>
<th colspan="9"><span style="color: #ed1c24;">Earth</span></th>
</tr>
<tr>
<th>Range</th>
<td colspan="8">20/200/2000Ω Auto-Ranging</td>
</tr>
<tr>
<th>Accuracy</th>
<td colspan="8">20Ω: ±3%rdg+0.1Ω<br />
200/2000Ω: ±3%rdg+3dgt (Auxiliary earth resistance 100±5%)</td>
</tr>
<tr>
<th colspan="9"><span style="color: #ed1c24;">Phase Rotation</span></th>
</tr>
<tr>
<th>Rated Voltage</th>
<td colspan="8">50-500V 50/60Hz</td>
</tr>
<tr>
<th>Remarks</th>
<td colspan="8">Correct phase sequence: are displayed &#8220;1.2.3&#8221; and <img loading="lazy" decoding="async" src="https://www.kew-ltd.co.jp/files/en/img/recycle_right.gif" width="20" height="20" /> cycle mark<br />
Reversed phase sequence: are displayed &#8220;3.2.1&#8221; and <img loading="lazy" decoding="async" src="https://www.kew-ltd.co.jp/files/en/img/recycle_right.gif" width="20" height="20" /> cycle mark</td>
</tr>
<tr>
<th colspan="9"><span style="color: #ed1c24;">Volts</span></th>
</tr>
<tr>
<th>Function</th>
<td colspan="5">Volts</td>
<td colspan="3">Frequency</td>
</tr>
<tr>
<th>Rated Voltage</th>
<td colspan="8">25 &#8211; 500V, 45 &#8211; 65Hz</td>
</tr>
<tr>
<th>Measuring range</th>
<td colspan="5">25 &#8211; 500V</td>
<td colspan="3">45 &#8211; 65Hz</td>
</tr>
<tr>
<th>Accuracy</th>
<td colspan="5">±2%rdg+4dgt</td>
<td colspan="3">±0.5%rdg+2dgt</td>
</tr>
</tbody>
</table>
</div>
</div>
<section class="mb10">
<table class="specTable mb0">
<tbody>
<tr>
<th>Applicable standards</th>
<td>IEC 61010-1 CAT III 300V (500V L to L) Pollution degree 2, IEC 61010-031,<br />
IEC 61557-1, 2, 3, 4, 5, 6, 7, 10, IEC 60529 (IP40), IEC 61326 (EMC)</td>
</tr>
<tr>
<th>Power source</th>
<td>LR6 X 8</td>
</tr>
<tr>
<th>Dimensions</th>
<td>136(L) X 235(W) X 114(D)mm</td>
</tr>
<tr>
<th>Weight</th>
<td>1350g (including batteries.)</td>
</tr>
<tr>
<th>Included Accessories</th>
<td>7188A (Distribution board fuse test lead set)<br />
7196A (Test leads with remote control switch)<br />
7218A (Power cord [AU) (*6)<br />
7228A (Earth resistance test leads)<br />
8032 (Auxiliary earth spikes)<br />
8212-USB (USB adaptor with KEW Report (Software))<br />
9142 (Carrying case)<br />
9121 (Shoulder strap)<br />
Cord case, Buckle, Battery, Instruction manual</td>
</tr>
<tr>
<th>Optional Accessories</th>
<td>8212-RS232C (RS232C adaptor with KEW Report (Software))</td>
</tr>
</tbody>
</table>
</section>
<div class="editor">
<p>(*1): Voltages are output when measurement resistance is under 2100 ohm.<br />
(*2): at 230V<br />
(*3): 230V+10%-15%<br />
(*4): voltages except for (*3)<br />
(*5): at 230V<br />
(*6): 7187A (Power cord [UK]), 7221A (Power cord [SA]), <strong>7222A (Power cord [AU])</strong></p>
<p><a target="_blank" href="https://mymeter.com.au/product/kyoritsu-6016-multi-function-electrical-tester/" rel="noopener noreferrer"><img loading="lazy" decoding="async" class="aligncenter wp-image-16672 size-full" src="https://rapid-tech.com.au/wp-content/uploads/2020/01/Buy-Now-Flir-Direct-sm.jpg" alt="" width="200" height="49" /></a></p>
</div>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-6016-multi-function-electrical-testers/">Kyoritsu 6016 Multi Function Electrical Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Kyoritsu 6010B Multi Function Tester</title>
		<link>https://rapid-tech.com.au/kyoritsu-6010b-multi-function-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Fri, 09 Feb 2018 02:05:54 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=6197</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-Authorised.jpg"><img class="alignnone size-full wp-image-7630" src="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-Authorised.jpg" alt="" width="250" height="69" /></a></p>
<p>&#160;</p>
<p><a target="_blank" href="https://mymeter.com.au/product/kyoritsu-6010b-multi-function-tester-2/" rel="noopener"><img class="alignnone size-full wp-image-17843" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/BUY-NOW-form-My-Meter-e1620004827208.png" alt="Buy now form My Meter" width="220" height="55" /></a></p>
<p>The Kyoritsu 6010B is an advanced multifunction meter that can perform continuity testing up to 200Ω with a short circuit currnet up to 200mA DC. Insulation resistance can also be measured up to 200MΩ with a 500 V DC test voltage. The 6010B integrates several safety features including a live circuit warning LED to indicate the circuit under test is live as well as integral overload protection on interal continuity and insulation test circuitry. Contact voltage (U<sub>c</sub>) can also be measured up to 100V.</p>
<ul>
<li>6 in 1 Tester - Continuity, Insulation, Contact Voltage, Loop and RCD Testing with Memory + Communication function.</li>
<li>Data Memory: 300 measured results</li>
<li>Continuity: 20/200Ω 200mA Test Current</li>
<li>Insulation: 500/1000V, 20/200MΩ 1mA Rated Test Current</li>
<li>Loop Impedance: 20/2000Ω, 15mA Test Current at 2000Ω (No RCD Trip)</li>
<li>RCD: 10/30/100/300/500mA, x1/2, x1, Fast Trip(40ms), DC, Auto Ramp</li>
<li>Test of a large kind of RCD's: Standard, Selective, AC &#38; A (DC sensitive breakers)</li>
</ul>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2018/02/6010B-Datasheet.pdf" rel="noopener"><span style="color: #0000ff;">6010B Multifunction Tester Datasheet</span></a></h3>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-6010b-multi-function-tester/">Kyoritsu 6010B Multi Function Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Kyoritsu 6010B can perform loop and RCD testing. This includes testing across a large range of currents (10/30/100/300/500 mA) and an auto ramp function. The Kyoritsu 6010B also features a built memory to store up to 300 measured results. The results can be downloaded to PC using the optional communication adaptor and &#8220;KEW Report&#8221; PC software.</p>
<p>The Kyoritsu 6010B is supplied with test leads, case, shoulder strap and batteries.</p>
<h3>Kyoritsu 6010B Features:</h3>
<p>• Continuity:20/200Ω 200mA Test Current<br />
• Insulation: 500/1000V, 20/200MΩ 1mA Rated Test Current<br />
• Loop Impedance:20/2000Ω 15mA Test Current at 2000Ω (No RCD Trip)<br />
• RCD:10/30/100/300/500mA x1/2, x1, Fast Trip(40ms), DC, Auto Ramp<br />
• Test of a large kind of RCD&#8217;s:Standard, Selective, AC and A(DC sensitive breakers)<br />
• Uc(Contact Voltage): 100V<br />
• Designed to IEC 61010-1, IEC 61557<br />
• Data Memory:300 measured results<br />
• The stored data can be transferred to PC via Optical Adaptor Model 8212-USB or 8212-RS232C.</p>
<h3>Kyoritsu 6010B Multifunction Tester Specifications:</h3>
<div class="editor">
<div class="tableScroller">
<table>
<tbody>
<tr bgcolor="#c8ebfb">
<th class="s4" colspan="3" valign="top">Continuity Testing</th>
</tr>
<tr>
<th class="s4" colspan="2" valign="top">Measuring Range</th>
<td class="s4" valign="top">20/200Ω (Auto-Ranging)</td>
</tr>
<tr>
<th class="s4" colspan="2" valign="top">Open Circuit Voltage</th>
<td class="s4" valign="top">&gt; 6V</td>
</tr>
<tr>
<th class="s4" colspan="2" valign="top">Short Circuit Current</th>
<td class="s4" valign="top">&gt; 200mA</td>
</tr>
<tr>
<th class="s4" colspan="2" valign="top">Accuracy</th>
<td class="s4" valign="top">±(3%rdg + 3dgt)</td>
</tr>
<tr bgcolor="#c8ebfb">
<th class="s4" colspan="3" valign="top">Insulation Resistance Testing</th>
</tr>
<tr>
<th class="s4" colspan="2" valign="top">Measuring Range</th>
<td class="s4" valign="top">20/200MΩ (Auto-Ranging)</td>
</tr>
<tr>
<th class="s4" colspan="2" valign="top">Test Voltage</th>
<td class="s4" valign="top">500/1000V</td>
</tr>
<tr>
<th class="s4" colspan="2" valign="top">Open Circuit Voltage</th>
<td class="s4" valign="top">+20% &#8211; 0%</td>
</tr>
<tr>
<th class="s4" colspan="2" valign="top">Rated Current</th>
<td class="s4" valign="top">&gt; 1mA</td>
</tr>
<tr>
<th class="s4" colspan="2" valign="top">Accuracy</th>
<td class="s4" valign="top">± (3%rdg + 3dgt)</td>
</tr>
<tr bgcolor="#c8ebfb">
<th class="s4" colspan="3" valign="top">Loop Impedance Testing</th>
</tr>
<tr>
<th class="s4" colspan="2" valign="top">Impedance Range</th>
<td class="s4" valign="top">20/2000Ω</td>
</tr>
<tr>
<th class="s4" colspan="2" valign="top">Rated Voltage</th>
<td class="s4" valign="top">230V + 10% &#8211; 15%(50Hz)</td>
</tr>
<tr>
<th class="s4" colspan="2" valign="top">Normal Test Current</th>
<td class="s4" valign="top">20Ω:25A/10ms<br />
2000Ω:15mA/350ms max.</td>
</tr>
<tr>
<th class="s4" colspan="2" valign="top">Accuracy</th>
<td class="s4" valign="top">±(3%rdg + 8dgt)</td>
</tr>
<tr bgcolor="#c8ebfb">
<th class="s4" colspan="3" valign="top">RCD Testing</th>
</tr>
<tr>
<th class="s4" rowspan="4" valign="top">Test Current<br />
(Test Current Duration)</th>
<th class="s4" valign="top">x1/2, x1</th>
<td class="s4" valign="top">10, 30, 100, 300, 500mA (2000ms)</td>
</tr>
<tr>
<th class="s4" valign="top">Fast</th>
<td class="s4" valign="top">150mA (50ms)</td>
</tr>
<tr>
<th class="s4" valign="top">DC</th>
<td class="s4" valign="top">10, 30, 100, 300mA (2000ms), 500mA (200ms)</td>
</tr>
<tr>
<th class="s4" valign="top">Auto Ramp</th>
<td class="s4" valign="top">Goes up by 10% from 20% to 110% of IΔn. 300ms×10</td>
</tr>
<tr>
<th class="s4" colspan="2" valign="top">Rated Voltage</th>
<td class="s4" valign="top">230V + 10% &#8211; 15% 50Hz</td>
</tr>
<tr>
<th class="s4" rowspan="2" valign="top">Accuracy</th>
<th class="s4" valign="top">Test Current</th>
<td class="s4" valign="top">x1/2: -8%-2%<br />
x1, FAST: +2%+8%<br />
DC: ±10%<br />
Auto Ramp: ±4%</td>
</tr>
<tr>
<th class="s4" valign="top">Trip Time</th>
<td class="s4" valign="top">±(1%rdg + 3dgt)</td>
</tr>
<tr bgcolor="#c8ebfb">
<th class="s4" colspan="3" valign="top">Uc Testing</th>
</tr>
<tr>
<th class="s4" colspan="2" valign="top">Measuring Range</th>
<td class="s4" valign="top">100V</td>
</tr>
<tr>
<th class="s4" colspan="2" valign="top">Rated Voltage</th>
<td class="s4" valign="top">230V + 10% &#8211; 15% (50Hz)</td>
</tr>
<tr>
<th class="s4" colspan="2" valign="top">Test Current</th>
<td class="s4" valign="top">5mA at IΔn = 10mA<br />
15mA at IΔn = 30/100mA<br />
150mA at IΔn = 300/500mA</td>
</tr>
<tr>
<th class="s4" colspan="2" valign="top">Accuracy</th>
<td class="s4" valign="top">+5% to +15%rdg±8dgt</td>
</tr>
</tbody>
</table>
</div>
</div>
<section class="mb10">
<table class="specTable mb0">
<tbody>
<tr>
<th>Safety Standard</th>
<td>IEC 61010-1 CAT III 300V Pollution Degree 2<br />
IEC 61557-1, 2, 3, 4, 6, 10, IEC 60529 (IP40)</td>
</tr>
<tr>
<th>Power source</th>
<td>R6 or LR6 × 8</td>
</tr>
<tr>
<th>Dimensions</th>
<td>115(L) × 175(W) × 86(D)mm</td>
</tr>
<tr>
<th>Weight</th>
<td>840g approx.</td>
</tr>
<tr>
<th>Included Accessories</th>
<td>7122B (Test leads)<br />
KAMP10* (Test Lead with IEC Connector)<br />
Pouch for Test leads<br />
Shoulder Strap<br />
Shoulder Pad<br />
Instruction Manual</td>
</tr>
<tr>
<th>Optional Accessories</th>
<td>7133B (Distribution board test leads)<br />
8212-RS232C (RS232C adaptor with &#8220;KEW Report (Software)&#8221;)<br />
8212-USB (USB adaptor with &#8220;KEW Report (Software)&#8221;)</td>
</tr>
</tbody>
</table>
</section>
<div class="editor">
<p>*KAMP10 (AU): Australian plug</p>
<h3>Kyoritsu 6010B Multifunction Tester Accessories</h3>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2018/02/Kyoritsu-6010B-options.jpg"><img loading="lazy" decoding="async" class="alignnone wp-image-6198 size-full" src="https://rapid-tech.com.au/wp-content/uploads/2018/02/Kyoritsu-6010B-options.jpg" alt="" width="888" height="291" srcset="https://rapid-tech.com.au/wp-content/uploads/2018/02/Kyoritsu-6010B-options.jpg 888w, https://rapid-tech.com.au/wp-content/uploads/2018/02/Kyoritsu-6010B-options-300x98.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2018/02/Kyoritsu-6010B-options-600x197.jpg 600w, https://rapid-tech.com.au/wp-content/uploads/2018/02/Kyoritsu-6010B-options-768x252.jpg 768w" sizes="auto, (max-width: 888px) 100vw, 888px" /></a></p>
</div>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-6010b-multi-function-tester/">Kyoritsu 6010B Multi Function Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Kyoritsu 4140 LOOP/PFC/PSC Tester</title>
		<link>https://rapid-tech.com.au/kyoritsu-4140-looppfcpsc-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Fri, 10 Nov 2017 18:27:31 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=5882</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-Authorised.jpg"><img class="alignnone size-full wp-image-7630" src="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-Authorised.jpg" alt="" width="250" height="69" /></a></p>
<p>&#160;</p>
<p><a target="_blank" href="https://mymeter.com.au/product/kyoritsu-4140-loop-pfc-psc-tester/" rel="noopener"><img class="alignnone size-full wp-image-17843" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/BUY-NOW-form-My-Meter-e1620004827208.png" alt="Buy now form My Meter" width="220" height="55" /></a></p>
<p>• Anti-Trip Technology for complete trip free Loop testing on all RCDs rated 30mA and above.<br />
• Dual Display allows simultaneous measurements like Loop &#38; PFC/PSC.<br />
• Two wire connection for Loop L-L, L-N and PSC testing is possible.<br />
• Phase rotation, Voltage and Frequency measurements.<br />
• Lock-down test button for 'hands free' testing with auto-start operation.<br />
• Display and front panel keyboards with Backlight to be visible in dark places.<br />
• Water and Dust proof (IP54)</p>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2017/11/Kyoritsu-4140-Datasheet.pdf" rel="noopener"><span style="color: #0000ff;">Kyoritsu 4140 Datasheet</span></a></h3>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-4140-looppfcpsc-tester/">Kyoritsu 4140 LOOP/PFC/PSC Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Kyoritsu 4140 LOOP/PFC/PSC Tester comes complete with everything you need for Loop, PFC, PSC and Phase rotation testing on an electrical installation according to the IEC 60364-6 (or its national equivalent standard).</p>
<p>The Kyoritsu 4140 measures prospective short current (PSC) and prospective fault current (PFC), phase rotation testing and both voltage and frequency. Designed to comply with an IP54 rating, the 4140 features anti-trip technology for trip free loop testing on RCDs rated to 30mA or above.</p>
<p>The Kyoritsu 4140 can test loop impedance up to 2000Ω via it&#8217;s 15mA AC test current. The prospesctive short current (PSC) and prospective fault current (PFC) can be read and the featured anti-trip technology allows trip free loop testing on all RCDs rated to 30mA or above. The dual digital display allows simultaneous measurements to be presented such as the loop and PFC/PSC.</p>
<p>The Kyoritsu 4140 provides the capabilities for &#8220;hands-free&#8221; testing with the lock-down test button with auto-start operation. As well as loop testing, the 4140 can perform phase rotation testing and both voltage and frequency measurements. The display and front panel keypad are backlit, providing operation in low light conditions.</p>
<p>Designed to an IP54 rating, the Kyoritsu 4140 is both waterproof and dustproof. The instrument is supplied with test leads, soft case, batteries and a shoulder strap.</p>
<p>With the Kyoritsu 4140 LOOP/PFC/PSC Tester a full set of new safety test leads is included, they have an overmould for maximum grip and are extremely robust.</p>
<p>The instrument also comes in a soft carry case, a quick reference guide locates on the instrument body, a strap belt and it is supplied with a calibration certificate.</p>
<figure id="attachment_5884" aria-describedby="caption-attachment-5884" style="width: 1000px" class="wp-caption aligncenter"><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/Kyoritsu-4140-Accessories.jpg"><img loading="lazy" decoding="async" class="wp-image-5884 size-full" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/Kyoritsu-4140-Accessories.jpg" alt="" width="1000" height="261" srcset="https://rapid-tech.com.au/wp-content/uploads/2017/11/Kyoritsu-4140-Accessories.jpg 1000w, https://rapid-tech.com.au/wp-content/uploads/2017/11/Kyoritsu-4140-Accessories-300x78.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2017/11/Kyoritsu-4140-Accessories-600x157.jpg 600w, https://rapid-tech.com.au/wp-content/uploads/2017/11/Kyoritsu-4140-Accessories-768x200.jpg 768w" sizes="auto, (max-width: 1000px) 100vw, 1000px" /></a><figcaption id="caption-attachment-5884" class="wp-caption-text">Kyoritsu 4140 Standard Accessories</figcaption></figure>
<h3>Kyoritsu 4140 LOOP/PFC/PSC Tester Specifications:</h3>
<div class="editor">
<h4 class="tm3">Loop Impedance</h4>
<table>
<tbody>
<tr>
<th>Function</th>
<td style="text-align: center;">L-PE ATT OFF</td>
<td style="text-align: center;">L-PE ATT ON</td>
<td style="text-align: center;">L-N / L-L</td>
</tr>
<tr>
<th>Rated Voltage</th>
<td colspan="2">230V (50/60Hz)</td>
<td>L-N: 230V (50/60Hz)<br />
L-L: 400V (50/60Hz)</td>
</tr>
<tr>
<th>Operating Voltage</th>
<td colspan="2">100 &#8211; 280V (45 &#8211; 65Hz)</td>
<td>100 &#8211; 500V (45 &#8211; 65Hz)</td>
</tr>
<tr>
<th>Range (Auto-Ranging)</th>
<td>20/200/2000Ω</td>
<td>20/200/2000Ω<br />
(L-N&lt;20Ω)</td>
<td>20Ω</td>
</tr>
<tr>
<th>Nominal Test Current at 0Ω External Loop: Magnitude/Duration at 230V</th>
<td>20Ω: 6A/40ms<br />
200Ω: 2A/20ms<br />
2000Ω: 15mA/500ms</td>
<td>L-N: 6A/60ms<br />
N-PE: 10mA/approx.5s</td>
<td>20Ω: 6A/20ms</td>
</tr>
<tr>
<th>Accuracy</th>
<td>±3%rdg±4dgt (*1)</td>
<td>±3%rdg±6dgt (*1)</td>
<td>L-N: ±3%rdg±4dgt<br />
L-L: ±3%rdg±8dgt</td>
</tr>
</tbody>
</table>
<h4 class="tm3">PFC (L-PE) / PSC (L-N / L-L) (*2)</h4>
<table>
<tbody>
<tr>
<th>Function</th>
<td style="text-align: center;">PFC</td>
<td style="text-align: center;">PFC (ATT)</td>
<td style="text-align: center;">PSC</td>
</tr>
<tr>
<th>Rated Voltage</th>
<td colspan="2">230V (50/60Hz)</td>
<td>L-N: 230V (50/60Hz)<br />
L-L: 400V (50/60Hz)</td>
</tr>
<tr>
<th>Operating Voltage</th>
<td colspan="2">100 &#8211; 280V (45 &#8211; 65Hz)</td>
<td>100 &#8211; 500V (45 &#8211; 65Hz)</td>
</tr>
<tr>
<th>Range (Auto-Ranging)</th>
<td>2000A/20kA</td>
<td>2000A/20kA (L-N&lt;20Ω)</td>
<td>2000A/20kA</td>
</tr>
<tr>
<th>Nominal Test Current at 0Ω External Loop: Magnitude/Duration at 230V</th>
<td>20Ω: 6A/40ms<br />
200Ω: 2A/20ms<br />
2000Ω: 15mA/500ms</td>
<td>L-N: 6A/60ms<br />
N-PE: 10mA/approx.5s</td>
<td>20Ω: 6A/20ms</td>
</tr>
</tbody>
</table>
<h4 class="tm3">Phase Rotation</h4>
<table style="height: 90px;" width="665">
<tbody>
<tr>
<th>Operating Voltage</th>
<td>50 &#8211; 500V, 45 &#8211; 65Hz</td>
</tr>
<tr>
<th>Remarks</th>
<td>Correct phase sequence: displayed &#8220;1.2.3&#8221; and <img loading="lazy" decoding="async" src="https://www.kew-ltd.co.jp/files/en/img/recycle_right.gif" width="20" height="20" /> mark<br />
Reversed phase sequence: displayed &#8220;3.2.1&#8221; and <img loading="lazy" decoding="async" src="https://www.kew-ltd.co.jp/files/en/img/recycle_right.gif" width="20" height="20" /> mark</td>
</tr>
</tbody>
</table>
<h4 class="tm3">Volts</h4>
<table style="height: 88px;" width="537">
<tbody>
<tr>
<th>Function</th>
<td style="text-align: center;">Volts</td>
<td style="text-align: center;">Frequency</td>
</tr>
<tr>
<th>Measuring range</th>
<td>0 &#8211; 500V</td>
<td>45 &#8211; 65Hz</td>
</tr>
<tr>
<th>Accuracy</th>
<td>±2%rdg±4dgt</td>
<td>±0.5%rdg±2dgt</td>
</tr>
</tbody>
</table>
</div>
<section class="mb10">
<table class="specTable mb0" style="height: 294px;" width="811">
<tbody>
<tr>
<th>Applicable standards</th>
<td>IEC 61010-1 CAT III 300V (500V L to L),<br />
IEC 61010-031, IEC 61557-1, 3, 7, 10,<br />
IEC 60529 (IP54), IEC 61326 (EMC)</td>
</tr>
<tr>
<th>Power source</th>
<td>1.5V AA batteries × 6 *Use of alkaline batteries (LR6) is recommended.</td>
</tr>
<tr>
<th>Dimensions</th>
<td>84 (L) × 184 (W) × 133 (D) mm</td>
</tr>
<tr>
<th>Weight</th>
<td>860g (including batteries)</td>
</tr>
<tr>
<th>Included Accessories</th>
<td>Main cord (*3)<br />
Distribution board test lead (*4)<br />
9155 (Shoulder strap)<br />
9156 (Soft case)<br />
LR6 (Battery) × 6, Instruction manual</td>
</tr>
</tbody>
</table>
</section>
<div class="editor">
<p>(*1): Accuracy of L-N LOOP displayed on the Sub Display is synchronized with the one at L-N/L-L function.<br />
(*2): PSC/PFC Accuracy is derived from measured loop impedance specification and measured voltage specification.<br />
(*3): 7187A (Power cord [UK]), 7218A (Power cord [EU]), 7221A (Power cord [SA]), <strong>7222A (Power cord [AU]) </strong><br />
(*4): 7246 (Blue, Green, Red), 7247 (Black, Green, Red)</p>
</div>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-4140-looppfcpsc-tester/">Kyoritsu 4140 LOOP/PFC/PSC Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Kyoritsu 4118A Digital Loop Impedance Tester</title>
		<link>https://rapid-tech.com.au/kyoritsu-4118a-digital-loop-impedance-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Wed, 30 Aug 2017 08:33:39 +0000</pubDate>
				<guid isPermaLink="false">http://rapid-tech.com.au/?post_type=product&#038;p=5451</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-Authorised.jpg"><img class="alignnone size-full wp-image-7630" src="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-Authorised.jpg" alt="" width="250" height="69" /></a></p>
<p><a target="_blank" href="https://mymeter.com.au/product/kyoritsu-4118a-digital-loop-impedance-tester" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<p>The Kyoritsu 4118A is a digital loop impedance tester that is able to measure prospective short current (PSC). Designed to comply with an IP54 rating, the 4118A is comprised of a custom microprocessor to achieve high accuracy and reliability.</p>
<p>Where the loop resistance of an earth circuit is too high and in the event of an overload or short circuit it is possible that that circuit breakers or earth leakage devices may become inoperative. To prevent such incidents, the earth circuit resistance must be measured to ensure it is sufficiently low.</p>
<h3><a href="http://rapid-tech.com.au/wp-content/uploads/2017/05/pdf_sml-1.png"><img class="alignnone size-full wp-image-5149" src="http://rapid-tech.com.au/wp-content/uploads/2017/05/pdf_sml-1.png" alt="pdf_sml" width="40" height="40" /></a>    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a href="http://rapid-tech.com.au/wp-content/uploads/2017/08/Kyoritsu-4118A-Datasheet.pdf">Kyoritsu 4118A Datasheet</a></span></span></h3>
<h3><a href="http://rapid-tech.com.au/wp-content/uploads/2017/05/pdf_sml-1.png"><img class="alignnone size-full wp-image-5149" src="http://rapid-tech.com.au/wp-content/uploads/2017/05/pdf_sml-1.png" alt="pdf_sml" width="40" height="40" /></a>    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a href="http://rapid-tech.com.au/wp-content/uploads/2017/08/Kyoritsu-4118A-User-Manual.pdf">Kyoritsu 4118A User Manual</a></span></span></h3>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-4118a-digital-loop-impedance-tester/">Kyoritsu 4118A Digital Loop Impedance Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Kyoritsu 4118A Digital Loop Impedance Tester contains 3 LEDs for checking correct wiring status and a visual indication of reversed phase and neutral wiring socket. An automatic lock-out feature is also present should the test resistor overheat. Designed to an IP54 rating, the 4118A possesses a large custom digital display and is supplied with test leads, cord case and shoulder strap.</p>
<h3>Kyoritsu 4118A Digital Loop Impedance Tester Features:</h3>
<p>• Custom microprocessor controlled for highest accuracy and reliability.<br />
• 3 LEDs for checking correct wiring status.<br />
• 15mA LOOP measurement: LOOP impedance 2000Ω range measurement is carried out with low test current (15mA).<br />
The current will not cause tripping out involved RCD even the one with the lowest nominal differential current (30mA).<br />
• Direct reading of Prospective Short Circuit Current (PSC).<br />
• Safe voltage measurement function.<br />
• Large custom digital display readout on all models.<br />
• Measure low loop resistances(resolution of 0.01Ω)<br />
• Automatic lock-out if test resister overheats.<br />
• Large custom digital display readout .<br />
• Visual indication of reversed phase and neutral wiring at socket.<br />
• Designed to IP54 Rating<br />
• Complies with IEC 61557</p>
<h3>Kyoritsu 4118A Digital Loop Impedance Tester Specifications:</h3>
<table>
<tbody>
<tr>
<th>Loop Impedance Ranges</th>
<td>20/200/2000Ω</td>
</tr>
<tr>
<th>Loop Impedance Accuracy</th>
<td>±2%rdg±4dgt</td>
</tr>
<tr>
<th>AC Test Current</th>
<td>20Ω 25A<br />
200Ω 2.3A<br />
2000Ω 15mA</td>
</tr>
<tr>
<th>AC Test Period</th>
<td>20Ω (20ms)<br />
200Ω (40ms)<br />
2000Ω (280ms)</td>
</tr>
<tr>
<th>PSC Ranges</th>
<td>200A (2.3A 40ms)<br />
2000A (25A 20ms)<br />
20kA (25A 20ms)</td>
</tr>
<tr>
<th>PSC Ranges Accuracy</th>
<td>Consider accuracy of Loop impedance</td>
</tr>
<tr>
<th>Voltage</th>
<td>110V-260V ±2%rdg±4dgt</td>
</tr>
<tr>
<th>Operating Voltage</th>
<td>230V+10% -15% (195V &#8211; 253V) 50Hz</td>
</tr>
<tr>
<th>Safety Standard</th>
<td>IEC 61010-1 CAT III 300V Pollution Degree 2<br />
IEC 61557-1,-3<br />
IEC 61010-2-031</td>
</tr>
<tr>
<th>IP Rating</th>
<td>IEC 60529-IP54</td>
</tr>
<tr>
<th>Dimensions</th>
<td>167(L) × 185(W) × 89(D)mm</td>
</tr>
<tr>
<th>Weight</th>
<td>750g approx.</td>
</tr>
<tr>
<th>Accessories</th>
<td>Molded plug test leads<br />
7121B (Simplified measurement probe)<br />
Pouch for test leads<br />
9121 (Shoulder Strap)<br />
Instruction Manual</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-4118a-digital-loop-impedance-tester/">Kyoritsu 4118A Digital Loop Impedance Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>