<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Leakage Current Tester Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/leakage-current-tester/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/leakage-current-tester/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Mon, 23 Mar 2026 04:05:39 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.7</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>Leakage Current Tester Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/leakage-current-tester/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>PROVA 11 Pro True RMS AC/DC mA Clamp Meter &#8211; Super High Resolution with Backlight and Auto-Power-Off &#8211; 200.0A Max DC Capability</title>
		<link>https://rapid-tech.com.au/prova-11-pro-true-rms-ac-dc-ma-clamp-meter/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Mon, 01 Apr 2024 23:48:35 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=27675</guid>

					<description><![CDATA[<h3><img class="alignnone size-full wp-image-839" src="https://rapid-tech.com.au/wp-content/uploads/2016/02/Prova_Logo.gif" alt="" width="154" height="52" /></h3>
<p><a target="_blank" href="https://mymeter.com.au/product/prova-11-pro-true-rms-ac-dc-ma-clamp-meter/" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<p>Elevate your electrical diagnostics with the PROVA 11 Pro AC/DC mA Clamp Meter (True RMS). Precision-engineered for the highest accuracy and reliability, this state-of-the-art tool offers unparalleled resolution with DC 1mA and AC 0.1mA, making it perfect for a myriad of professional applications. Boasting a maximum DC capability of 200.0A, a convenient 23mm jaw diameter, one-touch zero for DCA adjustment, auto-power-off, and an essential backlight for low-light conditions, the PROVA 11 Pro stands out as the quintessential instrument for electricians, technicians, and engineers. Experience True RMS for AC current and voltage measurement, a large LCD (6000 counts), and fast bargraph display for instant feedback. Featuring a dual range up to 200A DC and enhanced display with backlight, the PROVA 11 Pro surpasses its predecessor, offering superior performance for your most demanding tasks. Upgrade to the PROVA 11 Pro AC/DC mA Clamp Meter (True RMS) today and transform your approach to electrical measurement with precision, efficiency, and convenience.</p>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png"><img class="alignnone size-full wp-image-19718" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" /></a> <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2024/04/11-PRO-catalog-BACK-210717.pdf" rel="noopener">Prova 11 Pro — Datasheet</a><br />
<a href="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png"><img class="alignnone size-full wp-image-19718" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" /></a> <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2024/04/PA-11-DMM3-20140604.pdf" rel="noopener">User Manual</a></p>
<p>The post <a href="https://rapid-tech.com.au/prova-11-pro-true-rms-ac-dc-ma-clamp-meter/">PROVA 11 Pro True RMS AC/DC mA Clamp Meter &#8211; Super High Resolution with Backlight and Auto-Power-Off &#8211; 200.0A Max DC Capability</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Introducing the <b><strong class="font-bold">PROVA 11 Pro AC/DC mA Clamp Meter (True RMS)</strong></b> – the ultimate instrument for professionals who demand precision and reliability in electrical measurements. This state-of-the-art clamp meter is engineered to provide you with super high resolution, featuring DC at 1mA and AC at 0.1mA, making it perfect for precise current measurement tasks. With a maximum DC current capability of 200.0A and a jaw diameter of 23mm, the PROVA 11 Pro is versatile enough to handle a wide array of applications.</p>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Equipped with a one-touch zero for DCA adjustment, an auto-power-off feature to conserve energy, and a backlight for easy reading in low light conditions, the PROVA 11 Pro ensures convenience and efficiency. Its True RMS capability for AC current and voltage measurement, along with a large 3 5/6 digits LCD (6000 counts), and fast bargraph display, makes it superior for professionals who require accurate and quick feedback during their electrical testing and observations.</p>
<h4 class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr"><strong>Key Features:</strong></h4>
<ul class="pt-[9px] pb-[2px] pl-[24px] list-disc [&amp;_ul]:pt-[5px] pt-[5px]">
<li class="text-body font-regular text-gray-800 leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="1"><b><strong class="font-bold">Super High Resolution:</strong></b> DC 1mA, AC 0.1mA for detailed and accurate measurements.</li>
<li class="text-body font-regular text-gray-800 leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="2"><b><strong class="font-bold">Maximum Range:</strong></b> Capable of handling up to 200.0A of DC current.</li>
<li class="text-body font-regular text-gray-800 leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="3"><b><strong class="font-bold">User-Friendly Design:</strong></b> Features such as one-touch zero, auto-power-off, and a backlight for optimal usability.</li>
<li class="text-body font-regular text-gray-800 leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="4"><b><strong class="font-bold">True RMS:</strong></b> Offers accurate AC current/voltage measurements, accounting for variable loads.</li>
<li class="text-body font-regular text-gray-800 leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="5"><b><strong class="font-bold">Advanced Display:</strong></b> Large 3 5/6 digits LCD (6000 counts) and fast bargraph for immediate feedback.</li>
</ul>
<h3 class="font-bold text-gray-800 text-h4 leading-[30px] pt-[15px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]" dir="ltr">Comparison with PROVA 11</h3>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">When compared to its predecessor, the PROVA 11, the PROVA 11 Pro offers enhanced functionalities including a Dual Range up to 200A DC and a better Display with Backlight. It also boasts superior accuracy with ±1.5%+3dgts for DC mA and ±1.0%+3dgts for DC A, compared to the PROVA 11&#8217;s accuracy of ±2.0%+3dgts for both DC mA and DC A. Additionally, the PROVA 11 Pro supports higher voltage measurements up to 600.0V for both DCV and ACV, making it a more versatile tool for professionals.</p>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Whether you&#8217;re an electrician, technician, or engineer, the <b><strong class="font-bold">PROVA 11 Pro AC/DC mA Clamp Meter (True RMS)</strong></b> is designed to meet your needs for precise, reliable, and efficient electrical measurements. Upgrade your toolkit with the PROVA 11 Pro today and experience enhanced performance and convenience in all your electrical diagnostic tasks.</p>
<p>The post <a href="https://rapid-tech.com.au/prova-11-pro-true-rms-ac-dc-ma-clamp-meter/">PROVA 11 Pro True RMS AC/DC mA Clamp Meter &#8211; Super High Resolution with Backlight and Auto-Power-Off &#8211; 200.0A Max DC Capability</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PROVA A11 AC/DC mA Clamp Meter</title>
		<link>https://rapid-tech.com.au/prova-a11-ac-dc-ma-clamp-meter/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sun, 30 Jun 2019 10:30:10 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=12123</guid>

					<description><![CDATA[<h3><img class="alignnone size-full wp-image-839" src="https://rapid-tech.com.au/wp-content/uploads/2016/02/Prova_Logo.gif" alt="" width="154" height="52" /></h3>
<p><a target="_blank" href="https://mymeter.com.au/product/prova-a11-ac-dc-ma-clamp-meter/" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<h3>Features:</h3>
<ul>
<li>CAT IV 300V Safety Rating</li>
<li>Very high resolution DC 1mA, AC 0.1mA.</li>
<li>AC/DC (mA, A) current measurement: 6A / 60A.</li>
<li>AC/DC (V) voltage measurement: 60V / 600V.</li>
<li>AC current measurement: TRMS.</li>
<li>Resistance, Continuity, Capacitance, Diode and Temperature (℃/℉) measurement.</li>
<li>Voltage/Current Peak value measurement.</li>
<li>6000 Count Display</li>
</ul>
<h3><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" />    <span style="text-decoration: underline;"><a target="_blank" href="http://www.prova.com.tw/img/download/A11-DATA SHEET-EN-20180608.pdf" rel="noopener">PROVA A11 Datasheet</a></span></h3>
<p>The post <a href="https://rapid-tech.com.au/prova-a11-ac-dc-ma-clamp-meter/">PROVA A11 AC/DC mA Clamp Meter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>PROVA A11 AC/DC mA Clamp Meter</h3>
<ul>
<li>CAT IV 300V Safety Rating</li>
<li>Auto and Manual ranges for AC mA, AC/DC V, Resistance and Capacitance.</li>
<li> One Touch Zero for DCA adjustment.</li>
<li> Very high resolution DC 1mA, AC 0.1mA.</li>
<li> AC/DC (mA, A) current measurement: 6A / 60A.</li>
<li> AC/DC (V) voltage measurement: 60V / 600V.</li>
<li> AC current measurement: TRMS.</li>
<li> Resistance, Continuity, Capacitance, Diode and Temperature (℃/℉) measurement.</li>
<li> Voltage/Current Peak value measurement.</li>
<li> 6000 Count Display</li>
<li>  25mm large jaw diameter.</li>
<li>  Auto-power-off function (30 min.) and Backlight.</li>
<li>  Delta ( ) functions w.r.t. hold value.</li>
<li>  Dual display: Hold + Ave, Max + Min, Max + Min.</li>
<li>  Dual display (peak hold): Hold + Ave, Peak Max + Peak Min, Peak Max + Peak Min.\  Low Pass Filter (LPF, 1KHz, -3dB) (e.g. for VFD measurement)</li>
<li>  600V overload protection for Resistance and Capacitance measurement.</li>
<li>  Ideal for works in crowded switch box or cable areas.</li>
</ul>
<h3>PROVA A11  General Specifications:</h3>
<p>Conductor Size:   25mm max. (approx.)<br />
Battery Type:   two 1.5V SUM-3<br />
Display:   6000 counts<br />
Range Selection:   Auto and Manual<br />
Overload Indication:   OL<br />
Power Consumption:   17 mA (approx.)<br />
Sampling Time:   2 times/sec.<br />
Auto-power-off:   30 minutes<br />
Operating Temperature: 0°C to 50°C<br />
Operating Humidity: less than 85% relative<br />
Altitude: up to 2000M<br />
Storage Temperature: -20C to 60C<br />
Storage Humidity:   less than 75% relative<br />
Dimension:   190mm (L) x 66mm (W) x 36mm (H)<br />
Weight:   250g (battery included)</p>
<p><strong>Accessories:   </strong><br />
Carrying bag x 1<br />
Users manual x 1<br />
1.5V battery x 2<br />
Test leads x 1<br />
K-type thermocouples x 1<br />
Adapter (for Capacitance and K-type thermocouples) x 1</p>
<p>The post <a href="https://rapid-tech.com.au/prova-a11-ac-dc-ma-clamp-meter/">PROVA A11 AC/DC mA Clamp Meter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PROVA 23 Power Harmonics and Leakage Clamp Meter</title>
		<link>https://rapid-tech.com.au/prova-23-power-harmonics-and-leakage-clamp-meter/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Fri, 23 Nov 2018 01:22:28 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=9297</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2016/02/Prova_Logo.gif"><img class="alignnone size-full wp-image-839" src="https://rapid-tech.com.au/wp-content/uploads/2016/02/Prova_Logo.gif" alt="" width="154" height="52" /></a></p>
<p><a target="_blank" href="https://mymeter.com.au/product/prova-23-power-harmonics-and-leakage-tester/" rel="noopener"><img class="alignnone size-full wp-image-17843" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/BUY-NOW-form-My-Meter-e1620004827208.png" alt="Buy now form My Meter" width="220" height="55" /></a></p>
<p>The PROVA 23 Power Harmonics and Leakage Clamp Meter is a versatile instrument capable of measuring TRMS AC current and a wide range of power parameters, including Watts, active power, reactive power (VAR and KVAR), apparent power (VA and KVA), energy consumption (mWH, WH, and KWH), power factor (PF) and phase angle.</p>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2018/11/Prova-23-Datasheet.pdf" rel="noopener">Prova 23 Datasheet</a></span></h4>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2018/11/Prova-23-User-Manual.pdf" rel="noopener">Prova 23 User Manual</a></span></h4>
<p>The post <a href="https://rapid-tech.com.au/prova-23-power-harmonics-and-leakage-clamp-meter/">PROVA 23 Power Harmonics and Leakage Clamp Meter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4>PROVA 23 Power Harmonics and Leakage Clamp Meter Features:</h4>
<ul>
<li>True RMS value (V and A)</li>
<li>Leakage Current Measurement at 10 μ A Resolution</li>
<li>Harmonic Analysis (V and A) to the 99 th Order</li>
<li>High Frequency Harmonic Analysis (up to 5/6 KHz)</li>
<li>Non-interrupted Harmonic Analysis</li>
<li>Analysis of Total Harmonic Distortion (THD-F)</li>
<li>Analysis of Crest Factor (C.F.)</li>
<li>Fast Peak Function (33 μ s and 39 μ s)</li>
<li>Programmable CT Ratio (1 to 250)</li>
<li>100A</li>
</ul>
<h4>Measur</h4>
<h4>es:</h4>
<ul>
<li>W, KW, H.P.</li>
<li>VA, KVA, VAR, KVAR</li>
<li>PF, Phase Angle ( Φ )</li>
<li>Energy (mWH, WH, KWH)</li>
<li>Analysis of Standby Power Consumption</li>
<li>Balanced 3 Φ Power Quality</li>
</ul>
<h4>PROVA 23 Power Harmonics and Leakage Clamp Meter Specifications:</h4>
<h4><strong>AC Watts:</strong></h4>
<table width="613">
<tbody>
<tr>
<td colspan="6" width="613"><span style="font-size: 90%;">(50 or 60 Hz, PF 0.6~1, CT=1, Voltage is greater than AC 4V, Current is greater than AC 1mA for mA  range &amp; Current is greater than AC 0.04A for A range.Specification applies to continuous waveforms)</span></td>
</tr>
<tr>
<td width="187"><strong>Range (0 to 60A)</strong></td>
<td colspan="3" width="187"><strong>Resolution</strong></td>
<td colspan="2" width="239"><strong>Accuracy of Readings</strong></td>
</tr>
<tr>
<td width="187">0.050 – 9.999 W</td>
<td colspan="3" width="187">0.001W</td>
<td colspan="2" width="239">±2% ± 0.025W</td>
</tr>
<tr>
<td width="187">10.00 – 99.99 W</td>
<td colspan="3" width="187">0.01W</td>
<td colspan="2" width="239">±2% ± 0.25W</td>
</tr>
<tr>
<td width="187">100.0 &#8211; 999.9 W</td>
<td colspan="3" width="187">0.1W</td>
<td colspan="2" width="239">±2% ± 2.5W</td>
</tr>
<tr>
<td width="187">1.000 – 9.999 KW</td>
<td colspan="3" width="187">0.001 KW</td>
<td colspan="2" width="239">±2% ± 0.025KW</td>
</tr>
<tr>
<td width="187">10.00 – 99.99 KW</td>
<td colspan="3" width="187">0.01 KW</td>
<td colspan="2" width="239">±2% ± 0.25KW</td>
</tr>
<tr>
<td width="187">100.0 – 999.9 KW</td>
<td colspan="3" width="187">0.1 KW</td>
<td colspan="2" width="239">±2% ± 2.5KW</td>
</tr>
<tr>
<td width="187">1000 – 9999 KW</td>
<td colspan="3" width="187">1 KW</td>
<td colspan="2" width="239">±2% ± 25KW</td>
</tr>
<tr>
<td width="187">Range (60 – 100A)</td>
<td colspan="3" width="187">Resolution</td>
<td colspan="2" width="239">Accuracy</td>
</tr>
<tr>
<td width="187">0.050 – 9.999 W</td>
<td colspan="3" width="187">0.001W</td>
<td colspan="2" width="239">±2% of VA ± 5dgts</td>
</tr>
<tr>
<td width="187">10.00 – 99.99 W</td>
<td colspan="3" width="187">0.01W</td>
<td colspan="2" width="239">±2% of VA ± 5dgts</td>
</tr>
<tr>
<td width="187">100.0 &#8211; 999.9 W</td>
<td colspan="3" width="187">0.1W</td>
<td colspan="2" width="239">±2% of VA ± 5dgts</td>
</tr>
<tr>
<td width="187">1.000 – 9.999 KW</td>
<td colspan="3" width="187">0.001 KW</td>
<td colspan="2" width="239">±2% of VA ± 5dgts</td>
</tr>
<tr>
<td width="187">10.00 – 99.99 KW</td>
<td colspan="3" width="187">0.01 KW</td>
<td colspan="2" width="239">±2% of VA± 5dgts</td>
</tr>
<tr>
<td width="187">100.0 – 999.9 KW</td>
<td colspan="3" width="187">0.1 KW</td>
<td colspan="2" width="239">±2%of VA ± 5dgts</td>
</tr>
<tr>
<td width="187">1000 – 9999 KW</td>
<td colspan="3" width="187">1 KW</td>
<td colspan="2" width="239">±2% of VA ± 5dgts</td>
</tr>
</tbody>
</table>
<h4><strong>AC VOLTS:</strong></h4>
<table width="602">
<tbody>
<tr>
<td colspan="5" width="602"><span style="font-size: 90%;">(Auto Range, True RMS, Crest Factor&lt;4, Input Impedance 10 MΩ, Max. peak value 860VDC &amp; Overload Protection AC 800V)</span></td>
</tr>
<tr>
<td width="187"><strong>Range</strong></td>
<td width="127"><strong>Resolution</strong></td>
<td colspan="3" width="288"><strong>Accuracy of Readings (50/60Hz)</strong></td>
</tr>
<tr>
<td width="187">5V – 250 V</td>
<td width="127">0.1 V</td>
<td colspan="3" width="288">±0.5% ± 5dgts</td>
</tr>
<tr>
<td width="187">250 V – 600 V</td>
<td width="127">0.1 V</td>
<td colspan="3" width="288">±0.5% ± 5dgts</td>
</tr>
<tr>
<td width="187">Range</td>
<td width="127">Resolution</td>
<td colspan="3" width="288">Accuracy of Readings (45-1KHz)</td>
</tr>
<tr>
<td width="187">5V – 250 V</td>
<td width="127">0.1 V</td>
<td colspan="3" width="288">±1.5% ± 5dgts</td>
</tr>
<tr>
<td width="187">250 V – 600 V</td>
<td width="127">0.1 V</td>
<td colspan="3" width="288">±1.5% ± 5dgts</td>
</tr>
</tbody>
</table>
<h4><span style="font-size: 14.4px;"><br />
<span style="font-size: 100%;"><strong>AC CURRENT:</strong></span></span></h4>
<table width="602">
<tbody>
<tr>
<td colspan="5" width="602"><span style="font-size: 90%;">(Auto Range, True RMS, Crest Factor&lt;4, CT=1, Max. peak values 880mADC for mA range,</span></td>
</tr>
<tr>
<td colspan="5"><span style="font-size: 90%;"> 73.5ADC for A range, Overload Protection AC 600A)</span></td>
</tr>
<tr>
<td width="188"><strong>Range</strong></td>
<td colspan="2" width="125"><strong>Resolution</strong></td>
<td colspan="2" width="289"><strong>Accuracy of Readings (50/60Hz)</strong></td>
</tr>
<tr>
<td width="188">0.5 – 60mA</td>
<td colspan="2" width="125">0.01mA</td>
<td colspan="2" width="289">±0.5% ± 5dgts</td>
</tr>
<tr>
<td width="188">60 – 100mA</td>
<td colspan="2" width="125">0.01mA</td>
<td colspan="2" width="289">±0.5% ± 50dgts</td>
</tr>
<tr>
<td width="188">100 – 600 mA</td>
<td colspan="2" width="125">0.1 mA</td>
<td colspan="2" width="289">±0.5% ± 5dgts</td>
</tr>
<tr>
<td width="188">0.05 – 3 A</td>
<td colspan="2" width="125">0.001 A</td>
<td colspan="2" width="289">±0.5% ± 5dgts</td>
</tr>
<tr>
<td width="188">3 – 30 A</td>
<td colspan="2" width="125">0.01 A</td>
<td colspan="2" width="289">±0.5% ± 5dgts</td>
</tr>
<tr>
<td width="188">30 – 90 A</td>
<td colspan="2" width="125">0.01 A</td>
<td colspan="2" width="289">±1.0% ± 5dgts</td>
</tr>
<tr>
<td width="188">Range</td>
<td colspan="2" width="125">Resolution</td>
<td colspan="2" width="289">Accuracy of Readings (45-1KHz)</td>
</tr>
<tr>
<td width="188">0.5 – 60mA</td>
<td colspan="2" width="125">0.01mA</td>
<td colspan="2" width="289">±1.5% ± 5dgts</td>
</tr>
<tr>
<td width="188">60 – 100mA</td>
<td colspan="2" width="125">0.01mA</td>
<td colspan="2" width="289">±1.5% ± 50dgts</td>
</tr>
<tr>
<td width="188">100 – 600 mA</td>
<td colspan="2" width="125">0.1 mA</td>
<td colspan="2" width="289">±1.5% ± 5dgts</td>
</tr>
<tr>
<td width="188">0.05 – 3 A</td>
<td colspan="2" width="125">0.001 A</td>
<td colspan="2" width="289">±1.5% ± 5dgts</td>
</tr>
<tr>
<td width="188">3 – 30 A</td>
<td colspan="2" width="125">0.01 A</td>
<td colspan="2" width="289">±1.5% ± 5dgts</td>
</tr>
<tr>
<td width="188">30 – 90 A</td>
<td colspan="2" width="125">0.01 A</td>
<td colspan="2" width="289">±1.5% ± 5dgts</td>
</tr>
</tbody>
</table>
<h4>HARMONICS:</h4>
<table style="height: 489px;" width="639">
<tbody>
<tr>
<td colspan="6" width="614"><span style="font-size: 90%;">Harmonics of AC Voltage in Percentage   (1 to 99<sup>th</sup> order, minimum voltage at 50 or 60Hz is greater </span></td>
</tr>
<tr>
<td colspan="6"><span style="font-size: 90%;">than AC 80V. If the voltage is 0 at 50 or 60 Hz, all the percentage (%) display is 0.)</span></td>
</tr>
<tr>
<td colspan="2" width="200"><strong>Range</strong></td>
<td colspan="2" width="201"><strong>Resolution</strong></td>
<td colspan="2" width="213"><strong>Accuracy</strong></td>
</tr>
<tr>
<td colspan="2" width="200">1 – 10<sup>th</sup></td>
<td colspan="2">0.1 %</td>
<td colspan="2" width="213">±0.7% of reading ±1%</td>
</tr>
<tr>
<td colspan="2" width="200">11 – 20<sup>th</sup></td>
<td colspan="2">0.1 %</td>
<td colspan="2" width="213">±2% of reading ±1%</td>
</tr>
<tr>
<td colspan="2" width="200">21 – 50<sup>th</sup> (A range)</td>
<td colspan="2">0.1 %</td>
<td colspan="2" width="213">±5% of reading ±1%</td>
</tr>
<tr>
<td colspan="2" width="200">21 – 50<sup>th</sup> (mA range)</td>
<td colspan="2">0.1 %</td>
<td colspan="2" width="213">±10% of reading ±1%</td>
</tr>
<tr>
<td colspan="2" width="200">51 &#8211; 99<sup>th</sup></td>
<td colspan="2">0.1 %</td>
<td colspan="2" width="213">±35% of reading ±1%</td>
</tr>
<tr>
<td colspan="6"><strong>Harmonics of AC Voltage in Magnitude </strong>   (1 to 99<sup>th</sup> order, minimum voltage at 50 or 60 Hz is</td>
</tr>
<tr>
<td>greater than AC 80V)</td>
<td></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2" width="200"><strong>Range</strong></td>
<td colspan="2" width="201"><strong>Resolution</strong></td>
<td colspan="2" width="213"><strong>Accuracy</strong></td>
</tr>
<tr>
<td colspan="2" width="200">1 – 10<sup>th</sup></td>
<td colspan="2" width="201">0.1 V</td>
<td colspan="2" width="213">±0.7% of reading ±7dgts</td>
</tr>
<tr>
<td colspan="2" width="200">11 – 20<sup>th</sup></td>
<td colspan="2" width="201">0.1 V</td>
<td colspan="2" width="213">±2% of reading ±7dgts</td>
</tr>
<tr>
<td colspan="2" width="200">21 – 50<sup>th</sup> (A range)</td>
<td colspan="2" width="201">0.1 V</td>
<td colspan="2" width="213">±5% of reading ±7dgts</td>
</tr>
<tr>
<td colspan="2" width="200">21 – 50<sup>th</sup> (mA range)</td>
<td colspan="2" width="201">0.1 V</td>
<td colspan="2" width="213">±10% of reading ±7dgts</td>
</tr>
<tr>
<td colspan="2" width="200">51 &#8211; 99<sup>th</sup></td>
<td colspan="2" width="201">0.1 V</td>
<td colspan="2" width="213">±35% of reading ±7dgts</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table style="height: 295px;" width="676">
<tbody>
<tr>
<td colspan="6" width="614"><span style="font-size: 90%;">Harmonics of AC Current in Percentage    (1 to 99<sup>th</sup> order, minimum current at 50 or 60 Hz is greater than 100mA for mA range, and greater than 1A for A range. If the current is 0 at 50 or 60 Hz, all the percentage (%) display is 0.)</span></td>
</tr>
<tr>
<td colspan="2"></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2" width="200"><strong>Range</strong></td>
<td colspan="2" width="201"><strong>Resolution</strong></td>
<td colspan="2" width="213"><strong>Accuracy</strong></td>
</tr>
<tr>
<td colspan="2" width="200">1 – 10<sup>th</sup></td>
<td colspan="2">0.1 %</td>
<td colspan="2" width="213">±0.7% of reading ±1%</td>
</tr>
<tr>
<td colspan="2" width="200">11 – 20<sup>th</sup></td>
<td colspan="2">0.1 %</td>
<td colspan="2" width="213">±2% of reading ±1%</td>
</tr>
<tr>
<td colspan="2" width="200">21 – 50<sup>th</sup> (A range)</td>
<td colspan="2">0.1 %</td>
<td colspan="2" width="213">±5% of reading ±1%</td>
</tr>
<tr>
<td colspan="2" width="200">21 – 50<sup>th</sup> (mA range)</td>
<td colspan="2">0.1 %</td>
<td colspan="2" width="213">±10% of reading ±1%</td>
</tr>
<tr>
<td colspan="2" width="200">51 &#8211; 99<sup>th</sup></td>
<td colspan="2">0.1 %</td>
<td colspan="2" width="213">±35% of reading ±1%</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table width="613">
<tbody>
<tr>
<td colspan="6" width="549"><strong>Power Factor    </strong></p>
<p>(PF, ACV &gt; 4V, AC mA &gt; 1mA, AC A &gt; 0.04A, Watt &gt; 50 digits)</td>
<td width="64"></td>
</tr>
<tr>
<td colspan="2" width="200"><strong>Range</strong></td>
<td colspan="3" width="200"><strong>Resolution</strong></td>
<td colspan="2" width="213"><strong>Accuracy</strong></td>
</tr>
<tr>
<td colspan="2" width="200">0.000 – 1.000</td>
<td colspan="3">0.001</td>
<td colspan="2" width="213">±0.04</td>
</tr>
<tr>
<td colspan="3"><strong>Phase Angle </strong></p>
<p>(Φ, 50 or 60Hz)</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2" width="200"><strong>Range</strong></td>
<td colspan="3" width="200"><strong>Resolution</strong></td>
<td colspan="2" width="213"><strong>Accuracy</strong></td>
</tr>
<tr>
<td colspan="2" width="200">-180° to 180°</td>
<td colspan="3" width="200">0.1°</td>
<td colspan="2" width="213">± 2°</td>
</tr>
<tr>
<td colspan="2" width="200">0° to 360°</td>
<td colspan="3" width="200">0.1°</td>
<td colspan="2" width="213">± 2°</td>
</tr>
<tr>
<td colspan="3"><strong>Total Harmonic Distortion</strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="7"><span style="font-size: 90%;">(THD-F with respect to the first (fundamental) harmonics, min. value in the range from 45 to 65Hz is greater than AC 80V, greater than 1A for A range, and greater than 100mA for  mA range. Calculation is done over 1 to 50<sup>th</sup> Harmonics. If the voltage or current is 0 in the range from 45 to 65Hz, all the percentage (%) display is 0)</span></td>
</tr>
<tr>
<td colspan="2" width="200"><strong>Range (45~65Hz)</strong></td>
<td colspan="3" width="200"><strong>Resolution</strong></td>
<td colspan="2" width="213"><strong>Accuracy</strong></td>
</tr>
<tr>
<td colspan="2" width="200">0.0 – 20.0 %</td>
<td colspan="3">0.1%</td>
<td colspan="2" width="213">± 2%</td>
</tr>
<tr>
<td colspan="2" width="200">20.0 – 100%</td>
<td colspan="3">0.1%</td>
<td colspan="2" width="213">±3% of reading ± 5%</td>
</tr>
<tr>
<td colspan="2" width="200">100 – 999.9%</td>
<td colspan="3">0.1%</td>
<td colspan="2" width="213">±10% of reading ±10%</td>
</tr>
<tr>
<td colspan="7">Peak Value of AC Periodic Voltage (peak value&gt; 10V) or AC Periodic Current (peak value&gt;10mA   for   mA   range   and   peak   value&gt;0.5A   for   A   range)   for   continuous</td>
</tr>
<tr>
<td colspan="4">waveform except for square wave:</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2" width="200"><strong>Range</strong></td>
<td colspan="3" width="200"><strong>Sampling Time</strong></td>
<td colspan="2" width="213"><strong>Accuracy of Reading</strong></td>
</tr>
<tr>
<td colspan="2" width="200">50 Hz</td>
<td colspan="3" width="200">39 μs</td>
<td colspan="2" width="213">± 5% ± 30 digits</td>
</tr>
<tr>
<td colspan="2" width="200">60 Hz</td>
<td colspan="3" width="200">33 μs</td>
<td colspan="2" width="213">± 5% ± 30 digits</td>
</tr>
<tr>
<td colspan="7"><strong>Crest Factor</strong> (C.F.) of AC Voltage (peak value &gt; 10V) or AC Current (peak value&gt; 10mA  for  mA  range  and  peak  value&gt;0.5A  for  A  range)  for  continuous  waveform</td>
</tr>
<tr>
<td colspan="2">except for square wave:</td>
<td></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2" width="200"><strong>Range (45~65Hz)</strong></td>
<td colspan="3" width="200"><strong>Resolution</strong></td>
<td colspan="2" width="213"><strong>Accuracy of Readings</strong></td>
</tr>
<tr>
<td colspan="2" width="200">1.00 – 99.99</td>
<td colspan="3">0.01</td>
<td colspan="2" width="213">± 5% ± 30 digits</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table width="608">
<tbody>
<tr>
<td colspan="2" width="137"><strong>Frequency (Hz)</strong></td>
<td width="77"></td>
<td width="47"></td>
<td width="49"></td>
<td width="25"></td>
<td width="81"></td>
<td width="41"></td>
<td width="151"></td>
</tr>
<tr>
<td colspan="2" width="137"><strong>Range</strong></td>
<td colspan="2" width="124"><strong>Resolution</strong></td>
<td colspan="4" width="196"><strong>Accuracy of Readings</strong></td>
<td width="151"><strong>Allowed Input</strong></td>
</tr>
<tr>
<td colspan="2" width="137">mA (45 – 65Hz)</td>
<td colspan="2" width="124">0.1Hz</td>
<td colspan="4" width="196">± 0.5Hz</td>
<td width="151">20mA to 1.2A</td>
</tr>
<tr>
<td colspan="2" width="137">A (45 – 65Hz)</td>
<td colspan="2" width="124">0.1Hz</td>
<td colspan="4" width="196">± 0.5Hz</td>
<td width="151">1A to 100A</td>
</tr>
<tr>
<td colspan="7">Sensitivity: &gt; 20mA for mA range, &gt; 3A for A range, and &gt; 50V</td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="4"><strong><span style="font-size: 120%;">General Specifications:</span></strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="5" width="310">Conductor Size:</td>
<td colspan="4" width="298">30mm (approx.)</td>
</tr>
<tr>
<td colspan="5" width="310">Battery Type:</td>
<td colspan="4" width="298">two 1.5V SUM-3</td>
</tr>
<tr>
<td colspan="5" width="310">Display:</td>
<td colspan="4" width="298">4+2+2 digits LCD</td>
</tr>
<tr>
<td colspan="5" width="310">Range Selection:</td>
<td colspan="4" width="298">Auto</td>
</tr>
<tr>
<td colspan="5" width="310">Overload Indication:</td>
<td colspan="4" width="298">OL</td>
</tr>
<tr>
<td colspan="5" width="310">Power Consumption:</td>
<td colspan="4" width="298">10 mA (approx.)</td>
</tr>
<tr>
<td colspan="5" width="310">Low battery Indication:</td>
<td colspan="4" width="298">
<table>
<tbody>
<tr>
<td colspan="4" width="298"></td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td colspan="5" width="310">Auto-Power-Off:</td>
<td colspan="4" width="298">30 minutes after power-on</td>
</tr>
<tr>
<td colspan="5" width="310">Update Time:</td>
<td colspan="4" width="298">2 times/second (display)</td>
</tr>
<tr>
<td colspan="5" width="310">No. Of Samples per Period</td>
<td colspan="4" width="298">512 (voltage or current);<br />
256 (power)</td>
</tr>
<tr>
<td colspan="5" width="310">Temperature Coefficient (＜18℃ or  ＞28℃):</td>
<td colspan="4" width="298">0.15 x (Specified Accuracy) / ℃</td>
</tr>
<tr>
<td colspan="5" width="310">Operating Temperature:</td>
<td colspan="4" width="298">-10°C to 50°C</td>
</tr>
<tr>
<td colspan="5" width="310">Operating Humidity:</td>
<td colspan="4" width="298">less than 85% relative</td>
</tr>
<tr>
<td colspan="5" width="310">Altitude:</td>
<td colspan="4" width="298">up to 2000M</td>
</tr>
<tr>
<td colspan="5" width="310">Storage Temperature:</td>
<td colspan="4" width="298">-20°C to 60°C</td>
</tr>
<tr>
<td colspan="5" width="310">Storage Humidity:</td>
<td colspan="4" width="298">less than 75% relative</td>
</tr>
<tr>
<td colspan="5" width="310">Dimension:</td>
<td colspan="4" width="298">210mm (L) x 62mm (W) x 35.6mm (H)<br />
8.3&#8243; (L) x 2.5&#8243; (W) x 1.4&#8243; (H)</td>
</tr>
<tr>
<td colspan="5" width="310">Weight:</td>
<td colspan="4" width="298">200g (battery included)</td>
</tr>
<tr>
<td colspan="5" width="310">Accessories:</td>
<td colspan="4" width="298">Test leads x 1 pair, Carrying bag x 1, Users manual x 1,<br />
Batteries 1.5V x 2</td>
</tr>
<tr>
<td colspan="5" width="310">Option:</td>
<td colspan="4" width="298">Alligator clips</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/prova-23-power-harmonics-and-leakage-clamp-meter/">PROVA 23 Power Harmonics and Leakage Clamp Meter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PROVA Model CM-03 AC Leakage Current Tester</title>
		<link>https://rapid-tech.com.au/prova-model-cm-03-ac-leakage-current-tester/</link>
					<comments>https://rapid-tech.com.au/prova-model-cm-03-ac-leakage-current-tester/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 08 Mar 2016 23:22:55 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=1459</guid>

					<description><![CDATA[<p>&#160;</p>
<p><img class="alignnone size-full wp-image-839" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/Prova_Logo.gif" alt="Prova_Logo" width="154" height="52" /></p>
<p><a target="_blank" href="https://mymeter.com.au/product/prova-model-cm-03-ac-leakage-current-tester/" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<h2><span style="font-size: medium;">Features</span></h2>
<ul>
<li>Accurate AC/DC digital clamp meter for current measurements.</li>
<li>10<span style="font-family: Verdana;">µA resolution on 40mA range.</span></li>
<li>Shield transformer jaws to minimize the effect of external stray magnetic fields.</li>
<li>Jaw opening: 30mm diameter.</li>
<li>Large 3-3/4 digit Liquid Crystal Display.</li>
<li>Fast bargraph display for transient observation.</li>
<li>Five Ranges: 40mA, 400mA, 4A, 40A, and 60A for all applications.</li>
<li>Continuity and Frequency measurements.</li>
<li>Min/Max, Data Hold, and Relative measurements.</li>
<li>Easy single rotary switch for any function selection.</li>
<li>CAT II 600V, CAT III 300V.</li>
</ul>
<h4>Accessories supplied with instrument:</h4>
<p>Two 1.5 volt batteries (installed), User's Manual, and Carrying Bag.</p>
<p>&#160;</p>
<p><img class="alignnone size-full wp-image-1362" src="http://rapid-tech.com.au/wp-content/uploads/2016/03/CE-logo.png" alt="CE logo" width="44" height="29" />     <img class="alignnone size-full wp-image-1363" src="http://rapid-tech.com.au/wp-content/uploads/2016/03/ul-logo-black-2.png" alt="ul-logo-black (2)" width="30" height="30" /></p>
<p>&#160;</p>
<h4><img class="alignnone size-full wp-image-1367" src="http://rapid-tech.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="logopdf (2)" width="58" height="58" /> <a href="http://rapid-tech.com.au/wp-content/uploads/2016/03/Prova-1_CM-03_Datasheet.pdf">Prova-1_CM-03_Datasheet</a></h4>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/prova-model-cm-03-ac-leakage-current-tester/">PROVA Model CM-03 AC Leakage Current Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Are you looking for a reliable AC/DC digital clamp meter for current measurements? Look no further than the PROVA Model CM-03 tester! This powerful device is packed with features to make your current measurements easier and more accurate. From its 10µA resolution on 40mA range, to its five ranges of 40mA, 400mA, 4A, 40A, and 60A for all applications; this instrument has it all. Let’s take a closer look at what makes this tester so special.</p>
<p>The PROVA Model CM-03 comes with shield transformer jaws to minimize the effect of external stray magnetic fields. It also boasts a jaw opening of 30mm diameter, making it ideal for just about any setting. The large 3-3/4 digit Liquid Crystal Display gives you clear readings, while the fast bargraph display is perfect for transient observation. You can even take advantage of the Min/Max and Data Hold functions, as well as continuity and frequency measurements.</p>
<p>The easy single rotary switch allows you to select any function quickly and easily. With protection ratings of CAT II 600V or CAT III 300V, this tester is designed to last for years on end. Plus, with its affordable price tag, you won’t have to break the bank just to get a reliable current measurement device. With all these features, what more could you ask for? The PROVA Model CM-03 is the perfect choice for anyone looking to measure AC/DC currents accurately and efficiently. Get yours today!</p>
<h2>Features</h2>
<ul>
<li>Accurate AC/DC digital clamp meter for current measurements.</li>
<li>10µA resolution on 40mA range.</li>
<li>Shield transformer jaws to minimize the effect of external stray magnetic fields.</li>
<li>Jaw opening: 30mm diameter.</li>
<li>Large 3-3/4 digit Liquid Crystal Display.</li>
<li>Fast bargraph display for transient observation.</li>
<li>Five Ranges: 40mA, 400mA, 4A, 40A, and 60A for all applications.</li>
<li>Continuity and Frequency measurements.</li>
<li>Min/Max, Data Hold, and Relative measurements.</li>
<li>Easy single rotary switch for any function selection.</li>
<li>CAT II 600V, CAT III 300V.</li>
</ul>
<h4>Accessories supplied with instrument:</h4>
<p>Two 1.5 volt batteries (installed), User’s Manual, and Carrying Bag.</p>