<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Infrared Temperature Calibrators Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/infrared-temperature-calibrators-presys-instruments/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/infrared-temperature-calibrators-presys-instruments/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Thu, 20 May 2021 00:33:45 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.7</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>Infrared Temperature Calibrators Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/infrared-temperature-calibrators-presys-instruments/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>PRESYS T-500PIR Infrared Calibrator</title>
		<link>https://rapid-tech.com.au/presys-t-500pir-infrared-calibrator/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 21 Nov 2017 20:23:55 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=6009</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg"><img class="alignnone size-full wp-image-5972" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg" alt="" width="265" height="64" /></a></p>
<h4>NEW!!</h4>
<p>Using your cell phone or Android device with our Andromeda application, connected to the T-500PIR through Bluetooth, you can easily set-up the right compensated temperature of the T-500PIR black body following the Sakuma-Hattori equation. If you need to calibrate an IR thermometer with a different emissivity, it will automatically set-up the right temperature of the black body source.</p>
<ul id="produto">
<li>Generates temperatures from ambient to 500 °C.</li>
<li>Large target of 80 millimeters.</li>
<li>Ideal for the test and calibration of most infrared thermometers available in the industry.</li>
<li>High Accuracy: 0.4 °C + 0.1 % of reading – with internal sensor and 0.1 °C with external sensor.</li>
<li>Excellent temperature uniformity on the whole target surface.</li>
<li>Emissivity of 0.95 ± 0.01 °C for a wave-length from 8 µm to 14 µm.</li>
<li>Quickly reach the selected temperatures.</li>
<li>Temperature stability: 0.2 °C.</li>
<li>Configurable readings in °C or °F.</li>
<li>Sakuma-Hattori Emissivity compensation.</li>
<li>Bluetooth Interface.</li>
</ul>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="color: #0000ff;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2017/11/encomenda_2_157.pdf" rel="noopener">Presys T500PIR Datasheet</a></span></h3>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="color: #0000ff;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2017/11/Presys-T-150PIR-User-Manual.pdf" rel="noopener">Presys T-150PIR User Manual</a></span></h3>
<p>The post <a href="https://rapid-tech.com.au/presys-t-500pir-infrared-calibrator/">PRESYS T-500PIR Infrared Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The PRESYS T-500PIR Infrared Calibrator generates temperature values in order to enable the calibration of infrared thermometers. The temperatures generated have high accuracy, in an area of uniform temperature and emissivity.</p>
<p>The PRESYS T-500PIR Infrared Calibrator also has input for thermocouples and resistance thermometers, as well as current meter function.</p>
<ul>
<li>The T-500PIR generates temperature from ambient to 500 ºC.</li>
<li>Has input for thermocouples, RTDs and thermoswitches reading.</li>
<li>The use of external standard thermometer is not required*.</li>
<li>Carries out completely automatic calibrations with or without the use of a</li>
<li>Accuracy of up 0.4 ºC, stability of 0.2 °C and resolution of 0.01 ºC.</li>
<li>Documenting capabilities: communication with computer and ISOPLAN Calibration Software.</li>
<li>Portable and compact, has strap for easy</li>
</ul>
<p><em>* For high performance calibration, it is possible to make use of an external sensor RTD read in the input of the calibrator, with adjustment of the Callendar-Van Dusen coefficients.</em></p>
<p>It has extensive programming capabilities, where the calibrator is programmed to generate pre-set temperature.</p>
<p>Compatible with automatic calibration and documenting software, with application of ISOPLAN software on PC / Windows platform, using the serial port for connection between the PC and the calibrator that communicate via RS-232 or RS-485. ISOPLAN software can register thermometers and factory instruments, generate work orders, produce and print calibration certificates and reports, that is, all the information of power is brought into the environment of calibrations.</p>
<p><strong>T-500PIR has also many other features, such as:</strong></p>
<ul>
<li>The electric signal calibrator is independent from the blackbody target</li>
<li>Internal buzzer beeps when the temperature reaches the desired</li>
<li>Keypad that eases the operation and configuration of the</li>
<li>Vacuum Fluorescent Display to present big-size</li>
<li>Thermo-element reading scaled to ITS-90 or IPTS-68.</li>
<li>RTD reading configurable with Callendar-Van Dusen coefficients</li>
<li>Internal regulated 24Vdc power supply for 2-wire</li>
<li>Internal rechargeable battery and battery charger included in the electric signal calibrator.</li>
<li>Independent circuitry for over-temperature protection and</li>
</ul>
<p><iframe src="https://www.youtube.com/embed/30bYdHWHhWg" width="720" height="406" frameborder="0" allowfullscreen="allowfullscreen"></iframe></p>
<h3>PRESYS T-500PIR Infrared Calibrator Specifications:</h3>
<table>
<tbody>
<tr>
<td><span style="font-weight: 400;">Operating Range</span></td>
<td><span style="font-weight: 400;">ambient to 500 °C</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Power Supply</span></td>
<td><span style="font-weight: 400;">110 or 220 Vac, 50/60Hz</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Target Size</span></td>
<td><span style="font-weight: 400;">80 mm</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Resolution</span></td>
<td><span style="font-weight: 400;">± 0.01 °C</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Accuracy (internal reference)</span></td>
<td><span style="font-weight: 400;">± (0.4 °C + 0.1% of reading)</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">(external reference)</span></td>
<td><span style="font-weight: 400;">± 0.2 ºC </span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Target Emissivity (e):</span></td>
<td><span style="font-weight: 400;">0.95 ± 0.01</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Stability</span></td>
<td><span style="font-weight: 400;">± 0.2 °C</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Electric Power</span></td>
<td><span style="font-weight: 400;">1000 W</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Heating Time</span></td>
<td><span style="font-weight: 400;">35 minutes (50 ºC to 500 ºC)</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Cooling Time</span></td>
<td><span style="font-weight: 400;">30 min (500 °C to 100 °C)</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Units / temperature Scales</span></td>
<td><span style="font-weight: 400;">°C or °F / IPTS-68 or ITS-90,</span></p>
<p><span style="font-weight: 400;">user selectable</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Display</span></td>
<td><span style="font-weight: 400;">Graphic vacuum fluorescent with</span></p>
<p><span style="font-weight: 400;">contrast adjustment</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Target Uniformity</span></td>
<td><span style="font-weight: 400;">± 0.50 °C</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Dimensions (HxWxD)</span></td>
<td><span style="font-weight: 400;">260 x 180 x 270 mm</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Weight</span></td>
<td><span style="font-weight: 400;">5.2 kg</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Warranty</span></td>
<td><span style="font-weight: 400;">One year</span></td>
</tr>
</tbody>
</table>
<p><strong> </strong></p>
<table>
<tbody>
<tr>
<td colspan="2" width="341"><strong>Input Ranges</strong></td>
<td width="130"><strong>Resolution</strong></td>
<td width="134"><strong>Accuracy</strong></td>
<td width="148"><strong>Notes</strong></td>
</tr>
<tr>
<td width="105"><strong>millivolt</strong></td>
<td width="236">-150 to 150 mV</p>
<p>-500 to -150 mV</p>
<p>150 to 2450 mV</td>
<td width="130">0.001 mV</p>
<p>0.01 mV</p>
<p>0.01 mV</td>
<td width="134">± 0.01 % FS</p>
<p>± 0.02 % FS</p>
<p>± 0.02 % FS</td>
<td width="148">R<sub>input</sub> &gt; 10 MW auto-range</td>
</tr>
<tr>
<td width="105"><strong>mA</strong></td>
<td width="236">-5 to 24,5 mA</td>
<td width="130">0.0001 mA</td>
<td width="134">± 0.02 % FS</td>
<td width="148">R<sub>input</sub> &lt; 160 W</td>
</tr>
<tr>
<td width="105"><strong>Resistance</strong></td>
<td width="236">0 to 400 W</p>
<p>400 to 2500 W</td>
<td width="130">0.01 W</p>
<p>0.01 W</td>
<td width="134">± 0.01 % FS</p>
<p>± 0.03 % FS</td>
<td width="148">excitation current 0.9mA</td>
</tr>
<tr>
<td width="105"><strong>Pt-100</strong></td>
<td width="236">-200 to 850 ºC / -328 to 1562 ºF</td>
<td width="130">0.01 ºC / 0.01 ºF</td>
<td width="134">± 0.1 ºC / ± 0.2 ºF</td>
<td width="148">IEC-60751</td>
</tr>
<tr>
<td width="105"><strong>Pt-1000</strong></td>
<td width="236">-200 to 400 ºC / -328 to 752 ºF</td>
<td width="130">0.1 ºC / 0.1 ºF</td>
<td width="134">± 0.1 ºC / ± 0.2 ºF</td>
<td width="148">IEC-60751</td>
</tr>
<tr>
<td width="105"><strong>Cu-10</strong></td>
<td width="236">-200 to 260 ºC / -328 to 500 ºF</td>
<td width="130">0.1 ºC / 0.1 ºF</td>
<td width="134">± 2.0 ºC / ± 4.0 ºF</td>
<td width="148">Minco 16-9</td>
</tr>
<tr>
<td width="105"><strong>Ni-100</strong></td>
<td width="236">-60 to 250 ºC / -76 to 482 ºF</td>
<td width="130">0.1 ºC / 0.1 ºF</td>
<td width="134">± 0.2 ºC / ± 0.4 ºF</td>
<td width="148">DIN-43760</td>
</tr>
<tr>
<td width="105"><strong>TC-J</strong></td>
<td width="236">-210 to 1200 ºC / -346 to 2192 ºF</td>
<td width="130">0.1 ºC / 0.1 ºF</td>
<td width="134">± 0.2 ºC / ± 0.4 ºF</td>
<td width="148">IEC-60584</td>
</tr>
<tr>
<td width="105"><strong>TC-K</strong></td>
<td width="236">-270 to -150 ºC / -454 to -238 ºF</p>
<p>-150 to 1370 ºC / -238 to 2498 ºF</td>
<td width="130">0.1 ºC / 0.1 ºF</p>
<p>0.1 ºC / 0.1 ºF</td>
<td width="134">± 0.5 ºC / ± 1.0 ºF</p>
<p>± 0.2 ºC / ± 0.4 ºF</td>
<td width="148">IEC-60584</td>
</tr>
<tr>
<td width="105"><strong>TC-T</strong></td>
<td width="236">-260 to -200 ºC / -436 to -328 ºF</p>
<p>-200 to -75 ºC / -328 to -103 ºF</p>
<p>-75 to 400 ºC / -103 to 752 ºF</td>
<td width="130">0.1 ºC / 0.1 ºF</p>
<p>0.1 ºC / 0.1 ºF</p>
<p>0.1 ºC / 0.1 ºF</td>
<td width="134">± 0.6 ºC / ± 1.2 ºF</p>
<p>± 0.4 ºC / ± 0.8 ºF</p>
<p>± 0.2 ºC / ± 0.4 ºF</td>
<td width="148"><strong> </strong></p>
<p>IEC-60584</td>
</tr>
<tr>
<td width="105"><strong>TC-E</strong></td>
<td width="236">-270 to -150 ºC / -454 to -238 ºF</p>
<p>-150 to 1000 ºC / -238 to 1832 ºF</td>
<td width="130">0.1 ºC / 0.1 ºF</p>
<p>0.1 ºC / 0.1 ºF</td>
<td width="134">± 0.3 ºC / ± 0.6 ºF</p>
<p>± 0.1 ºC / ± 0.2 ºF</td>
<td width="148">IEC-60584</td>
</tr>
<tr>
<td width="105"><strong>TC-N</strong></td>
<td width="236">-260 to -200 ºC / -436 to -328 ºF</p>
<p>-200 to -20 ºC / -328 to -4 ºF</p>
<p>-20 to 1300 ºC / -4 to 2372 ºF</td>
<td width="130">0.1 ºC / 0.1 ºF</p>
<p>0.1 ºC / 0.1 ºF</p>
<p>0.1 ºC / 0.1 ºF</td>
<td width="134">± 1.0 ºC / ± 2.0 ºF</p>
<p>± 0.4 ºC / ± 0.8 ºF</p>
<p>± 0.2 ºC / ± 0.4 ºF</td>
<td width="148"><strong> </strong></p>
<p>IEC-60584</td>
</tr>
<tr>
<td width="105"><strong>TC-L</strong></td>
<td width="236">-200 to 900 ºC / -328 to 1652 ºF</td>
<td width="130">0.1 ºC / 0.1 ºF</td>
<td width="134">± 0.2 ºC / ± 0.4 ºF</td>
<td width="148">DIN-43710</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>The post <a href="https://rapid-tech.com.au/presys-t-500pir-infrared-calibrator/">PRESYS T-500PIR Infrared Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PRESYS T-30NIR Infrared Calibrator</title>
		<link>https://rapid-tech.com.au/presys-t-30nir-infrared-calibrator/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 21 Nov 2017 08:16:38 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=5998</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg"><img class="alignnone size-full wp-image-5972" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-LOGO.jpg" alt="" width="265" height="64" /></a></p>
<p>The PRESYS T-30NIR Infrared Calibrator is a high performance, rugged, portable calibrator for calibrating and verifying infrared thermometers.</p>
<h3><span style="text-decoration: underline;"><strong><span style="color: #ff0000; text-decoration: underline;">New Feature !</span></strong></span></h3>
<p><strong>And now using your cell phone or Android device with our Andromeda application, connected to the T-30NIR through Bluetooth, you can easily set-up the right compensated temperature of the T-30NIR black body following the Sakuma-Hattori equation. </strong></p>
<p><strong>If you need to calibrate an IR thermometer with a different emissivity, it will automatically set-up the right temperature of the black body source</strong>.</p>
<h4><strong>Features:</strong></h4>
<ul id="produto">
<li>Generates temperatures from -30 °C to 150 °C.</li>
<li>Very practical to use, facilitates calibration.</li>
<li>It can be used with external reference thermometer.</li>
<li>Includes a front cover and a connection for dry air blowing on the target edges which prevents the ice formation.</li>
<li>Large target of 80 millimeters.</li>
<li>Ideal for the test and calibration of most infrared thermometers available in the industry.</li>
<li>High accuracy: 0.4 °C with internal sensor and 0.1°C with external sensor.</li>
<li>Excellent temperature uniformity on the whole target surface.</li>
<li>Emissivity of 0.95 ± 0.02 for a wave-length from 8 µm to 14 µm.</li>
<li>Quickly reaches the selected temperatures.</li>
<li>Temperature stability: 0.1 °C.</li>
<li>Configurable readings in °C or °F.</li>
</ul>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2017/11/PRESYS-T-30NIR-NEW-Datasheet.pdf" rel="noopener noreferrer">PRESYS T-30NIR-NEW Datasheet</a></span></h3>
<p>The post <a href="https://rapid-tech.com.au/presys-t-30nir-infrared-calibrator/">PRESYS T-30NIR Infrared Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>PRESYS T-30NIR Infrared Calibrator</h3>
<p>The PRESYS T-30NIR Infrared Calibrator is a high performance, rugged, portable calibrator for infrared thermometers. The PRESYS T-30NIR Hot/Cold model has a range of -30 °C to 150 °C. with the ability to provide a stable, repeatable cold calibration point that allows the user to calibrate or test most infrared thermometers quickly and accurately without having to prepare an ice bath. The target plate has a known emissivity, enabling the user to calibrate virtually any infrared thermometer with a spot size diameter of 80 mm or smaller.</p>
<p>The Presys T-30NIR is practical to use which simplifies the calibration proceedure. It can be used with an external reference thermometer for increased accuracy. Includes a front cover and a connection for dry air blowing on the target edges which prevents the ice formation.</p>
<p style="text-align: center;"><iframe src="https://www.youtube.com/embed/30bYdHWHhWg" width="720" height="406" frameborder="0" allowfullscreen="allowfullscreen"></iframe></p>
<p>&nbsp;</p>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/T-30NIR-New-Spec.jpg"><img fetchpriority="high" decoding="async" class="aligncenter wp-image-16439 size-full" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/T-30NIR-New-Spec.jpg" alt="" width="1000" height="256" srcset="https://rapid-tech.com.au/wp-content/uploads/2017/11/T-30NIR-New-Spec.jpg 1000w, https://rapid-tech.com.au/wp-content/uploads/2017/11/T-30NIR-New-Spec-300x77.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2017/11/T-30NIR-New-Spec-600x154.jpg 600w, https://rapid-tech.com.au/wp-content/uploads/2017/11/T-30NIR-New-Spec-768x197.jpg 768w" sizes="(max-width: 1000px) 100vw, 1000px" /></a></p>
<p>&nbsp;</p>
<p>The post <a href="https://rapid-tech.com.au/presys-t-30nir-infrared-calibrator/">PRESYS T-30NIR Infrared Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
