The GWINSTEK ASR-2000 series, is a AC+DC power source aiming for system integration or desktop applications, provides both rated power output for AC output and rated power output for DC output.
Nine ASR-2000 output modes are available, including
1) AC power output mode (AC-INT Mode),
2) DC power output mode (DC-INT Mode),
3) AC/DC power output mode (AC+DC-INT Mode),
4) External AC signal source mode (AC-EXT Mode),
5) External AC/DC signal source mode (AC+DC-EXT Mode),
6) External AC signal superposition mode (AC-ADD Mode),
7) External AC/DC signal superposition mode (AC+DC-ADD Mode),
8) External AC signal synchronization mode (AC-SYNC Mode),
9) External AC/DC signal synchronization mode (AC+DC-SYNC Mode).
The GW INSTEK ASR-2000 series provides users with waveform output capabilities to meet the test requirements of different electronic component development, automotive electrical devices and home appliance, including 1) Sequence mode generates waveform fallings, surges, sags, changes and other abnormal power line conditions; 2) Arbitrary waveform function allows users to store/upload user-defined waveforms; and 3) Simulate mode simulates power outage, voltage rise, voltage fall, and frequency variations.
When the ASR-2000 series power source outputs, it can also measure Vrms, Vavg, Vpeak, Irms, Iavg, Ipeak, IpkH, P, S, Q, PF, CF, 40th-order Voltage Harmonic and Current Harmonic. In addition, the Remote sense function ensures accurate voltage output. The Customized Phase Angle for Output On/Off function can set the starting angle and ending angle of the voltage output according to the test requirements. V-Limit, Ipeak-Limit, F-Limit, OVP, OCP, OPP function settings can protect the DUT during the measurement process. In addition to OTP, OCP, and OPP protection, the ASR-2000 series also incorporates the Fan fail alarm function and AC fail alarm function.
GW INSTEK ASR-2000 SpecificationsThe specifications apply when the ASR-2000 is powered on for at least 30 minutes under +20°C~+30°C. | |||||
Input Ratings (AC rms) | |||||
Model | ASR-2050/ASR-2050R | ASR-2100/ASR-2100R | |||
Norminal input voltage | 100 Vac to 240 Vac | ||||
Input voltage range | 90 Vac to 264 Vac | ||||
Phase | Single phase, Two-wire | ||||
Input frequency range | 47 Hz to 63 Hz | ||||
Max. power consumption | 800 VA or less | 1500 VA or less | |||
Power factor*1 | 100Vac | 0.95 (typ.) | |||
200Vac | 0.90 (typ.) | ||||
Max. input current | 100Vac | 8 A | 15 A | ||
200Vac | 4 A | 7.5 A | |||
*1. For an output voltage of 100 V/200 V (100V / 200V range), maximum current, and a load power factor of 1. | |||||
AC Mode Output Ratings (AC rms) | |||||
Model | ASR-2050/ASR-2050R | ASR-2100/ASR-2100R | |||
Voltage | Setting Range*1 | 0.0 V to 175.0 V / 0.0 V to 350.0 V | |||
Setting Resolution | 0.1 V | ||||
Accuracy*2 | ±(0.5 % of set + 0.6 V / 1.2 V) | ||||
Output phase | Single phase, Two-wire | ||||
Maximum current*3 | 100 V | 5 A | 10 A | ||
200 V | 2.5 A | 5 A | |||
Maximum peak current*4 | 100 V | 20 A | 40 A | ||
200 V | 10 A | 20 A | |||
Power capacity | 500 VA | 1000 VA | |||
Frequency | Setting range | AC Mode: 40.00 Hz to 999.9 Hz, AC+DC Mode: 1.00 Hz to 999.9 Hz | |||
Setting resolution | 0.01 Hz (1.00 to 99.99 Hz), 0.1 Hz (100.0 to 999.9 Hz) | ||||
Accuracy | For 45 Hz to 65 Hz: 0.01% of set For 40 Hz to 999.9 Hz: 0.02% of set | ||||
Stability*5 | ± 0.005% | ||||
Output on phase | 0.0° to 359.9° variable (setting resolution 0.1°) | ||||
DC offset*6 | Within ± 20 mV (TYP) | ||||
*1. 100 V / 200 V range *2. For an output voltage of 17.5 V to 175 V / 35 V to 350 V, sine wave, an output frequency of 45 Hz to 65 Hz, no load, DC voltage setting 0V (AC+DC mode) and 23°C ± 5°C *3. For an output voltage of 1 V to 100 V / 2 V to 200 V. Limited by the power capacity when the output voltage is 100 V to 175 V / 200 V to 350 V. *4. With respect to the capacitor-input rectifying load. Limited by the maximum current. *5. For 45 Hz to 65 Hz, the rated output voltage, no load and the resistance load for the maximum current, and the operating temperature. *6. In the case of the AC mode and output voltage setting to 0 V. | |||||
Output Rating for DC Mode | |||||
Model | ASR-2050/ASR-2050R | ASR-2100/ASR-2100R | |||
Voltage | Setting Range*1 | -250 V to +250 V / -500 V to +500 V | |||
Setting Resolution | 0.1 V | ||||
Accuracy*2 | ±(|0.5 % of set| + 0.6 V / 1.2 V) | ||||
Maximum current*3 | 100 V | 5 A | 10 A | ||
200 V | 2.5 A | 5 A | |||
Maximum peak current*4 | 100 V | 20 A | 40 A | ||
200 V | 10 A | 20 A | |||
Power capacity | 500 W | 1000 W | |||
*1. 100 V / 200 V range *2. For an output voltage of -250 V to -25 V, +25 V to +250 V / -500 V to -50 V, +50 V to +500 V, no load, AC volatge setting 0V (AC+DC mode) and 23℃ ± 5℃ *3. For an output voltage of 1.4 V to 100 V / 2.8 V to 200 V. Limited by the power capacity when the output voltage is 100 V to 250 V / 200 V to 500 V. *4. Within 5 ms, Limited by the maximum current. | |||||
Output Voltage Stability | |||||
Model | ASR-2050/ASR-2050R | ASR-2100/ASR-2100R | |||
Line regulation*1 | ±0.2% or less | ||||
Load regulation*2 | 0.15% @45 – 65Hz 0.5% @DC, all other frequencies (0 to 100%, via output terminal) | ||||
Ripple noise*3 | 0.7 Vrms / 1.4 Vrms (TYP) | ||||
*1. Power source input voltage is 100 V, 120 V, or 230 V, no load, rated output. *2. For an output voltage of 75 V to 175 V / 150 V to 350 V, a load power factor of 1, stepwise change from an output current of 0 A to maximum current (or its reverse), using the output terminal on the rear panel. *3. For 5 Hz to 1 MHz components in DC mode using the output terminal on the rear panel. | |||||
Output Voltage Waveform Distortion Ratio, Output Voltage Response Time, Efficiency | |||||
Model | ASR-2050/ASR-2050R | ASR-2100/ASR-2100R | |||
Output voltage waveform distortion ratio*1 | 0.5 % or less | ||||
Output voltage response time*2 | 100 us (TYP) | ||||
Efficiency*3 | 70 % or more | ||||
*1. At an output voltage of 50 V to 175 V / 100 V to 350 V, a load power factor of 1, and in AC and AC+DC mode. *2. For an output voltage of 100 V / 200 V, a load power factor of 1, with respect to stepwise change from an output current of 0 A to the maximum current (or its reverse). 10% ~ 90% of output voltage *3. For AC mode, at an output voltage of 100 V / 200 V, maximum current, and load power factor of 1 and sine wave only. | |||||
Measured Value Display | |||||
All accuracy of the measurement function is indicated for 23 °C±5 °C. | |||||
Model | ASR-2050/ASR-2050R | ASR-2100/ASR-2100R | |||
Voltage | RMS, AVG value*1 | Resolution | 0.1 V | ||
Accuracy*2 | For 45 Hz to 65 Hz and DC: ±(0.5 % of reading + 0.3 V / 0.6 V) For 40 Hz to 999.9 Hz: ±(0.7 % of reading + 0.9 V / 1.8 V) |