<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Fuses Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/fuses-fluke/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/fuses-fluke/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Wed, 26 Nov 2025 01:09:13 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.5</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>Fuses Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/fuses-fluke/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Fluke 440 mA fuse assembly for Fluke 28 II Ex Intrinsically Safe Multimeter</title>
		<link>https://rapid-tech.com.au/fluke-440-ma-fuse-assembly/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Fri, 28 May 2021 06:29:02 +0000</pubDate>
				<guid isPermaLink="false">https://fluke-test.com.au/?post_type=product&#038;p=1366</guid>

					<description><![CDATA[<p>&#160;</p>
<h3><img class="alignnone size-full wp-image-679" src="https://rapid-tech.com.au/wp-content/uploads/2020/07/Fluke-Logo-Small.png" alt="" width="200" height="67" /><br />
Fluke 440 mA fuse assembly</h3>
<h4>Features</h4>
<ul>
<li>Designed <strong>for Fluke 28 II Ex Intrinsically Safe multimeters</strong></li>
<li>Designed to prevent detonation of explosive atmospheres</li>
<li><strong>Part of the intrinsically safe product design</strong></li>
</ul>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/fluke-440-ma-fuse-assembly/">Fluke 440 mA fuse assembly for Fluke 28 II Ex Intrinsically Safe Multimeter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Fluke 440 mA fuse assembly</h2>
<p>The Fluke 28II Ex Intrinsically Safe digital multimeter is designed to prevent the accidental detonation of explosive atmospheres.</p>
<p><strong>Using the correct replacement fuse block is essential to the safety of that design.</strong> The Fluke 440 mA fuse assembly is specifically designed to be used in the 28II.</p>
<h4>Used in the following Fluke Digital Multimeters</h4>
<p>Fluke 28 II Ex Intrinsically Safe True RMS Digital Multimeter</p>
<p>The post <a href="https://rapid-tech.com.au/fluke-440-ma-fuse-assembly/">Fluke 440 mA fuse assembly for Fluke 28 II Ex Intrinsically Safe Multimeter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 315mA 1000V Fuse</title>
		<link>https://rapid-tech.com.au/fluke-315ma-1000v-fuse/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Fri, 28 May 2021 06:06:22 +0000</pubDate>
				<guid isPermaLink="false">https://fluke-test.com.au/?post_type=product&#038;p=1363</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-679" src="https://rapid-tech.com.au/wp-content/uploads/2020/07/Fluke-Logo-Small.png" alt="" width="200" height="67" /></p>
<h3>Fluke 315mA 1000V Fuse</h3>
<h4>Features:</h4>
<ul>
<li>315 milliamp, 1000 volt fuse for Fluke insulation testers</li>
<li>High-energy, fast-release fuse designed measuring current</li>
<li>Sand-filled to reduce risk of breakage during current overloads</li>
</ul>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/fluke-315ma-1000v-fuse/">Fluke 315mA 1000V Fuse</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Fluke 315mA 1000V Fuse</h3>
<p>This is a high-energy fuse is designed to keep the energy generated by an electrical short within the fuse enclosure. This protects the user from electric shock and burns. The Fluke 315 mA 1000 V fuse is designed to limit the amount of oxygen available for combustion and the length of time the energy is applied.</p>
<p>This 1000 V fuse is sand-filled to absorb the shock energy created by the current overload. The and will also help absorb the high temperatures (up to 10,000 °F) generated. The energy will melt the sand and turn it to glass, helping smother a potential fireball by cutting off the available oxygen, further protecting the user.</p>
<h4>Fluke tester fuse replacement compatibility guide</h4>
<ul>
<li style="list-style-type: none;">
<ul>
<li>Fluke 1503 Insulation Resistance Meter</li>
<li>Fluke 1507 Insulation Resistance Tester</li>
</ul>
</li>
</ul>
<p>The post <a href="https://rapid-tech.com.au/fluke-315ma-1000v-fuse/">Fluke 315mA 1000V Fuse</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 440mA 1000V Fuse &#124; DMM 44/100A</title>
		<link>https://rapid-tech.com.au/fluke-440ma-1000v-fuse-dmm-44-100a/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Fri, 28 May 2021 05:45:13 +0000</pubDate>
				<guid isPermaLink="false">https://fluke-test.com.au/?post_type=product&#038;p=1361</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-679" src="https://rapid-tech.com.au/wp-content/uploads/2020/07/Fluke-Logo-Small.png" alt="" width="200" height="67" /></p>
<h3>Fluke 440mA 1000V Fuse &#124; DMM 44/100A</h3>
<h4>Features:</h4>
<ul>
<li style="list-style-type: none;">
<ul>
<li>440 milliamp, 1000 volt fuse for Fluke digital multimeters</li>
<li>High-energy and fast-release fuse designed measuring current</li>
<li>Sand-filled to quickly cut off available oxygen in case of short</li>
</ul>
</li>
</ul>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/fluke-440ma-1000v-fuse-dmm-44-100a/">Fluke 440mA 1000V Fuse | DMM 44/100A</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Fluke 440mA 1000V Fuse | DMM 44/100A</h3>
<p>When an electrical short occurs while making a current measurement, the user relies upon the high-energy fuse in the test tool for protection. The Fluke 440 mA, 1000 V fuse is designed to keep the energy generated within the fuse enclosure, protecting the user from electric shock and burns.</p>
<p>This fuse limits the length of time energy is applied and the amount of oxygen available for combustion.</p>
<p>The Fluke 440 mA 1000 V high-energy fuse is sand-filled which helps absorb the shock energy created by the current overload. It also controls the potential high temperatures generated (up to 10,000 °F).</p>
<p>The energy created from an electrical short will melt the sand, turning it to glass. This helps smother a potential fireball by quickly cutting off the available oxygen, further protecting the user.</p>
<h3>Fluke 440mA 1000V Fuse is used in the multimeters</h3>
<ul>
<li style="list-style-type: none;">
<ul>
<li>Fluke 1577 Insulation Multimeter</li>
<li>Fluke 1587 FC Insulation Multimeter</li>
<li>Fluke 177 True-RMS Digital Multimeter</li>
<li>Fluke 179 True-RMS Digital Multimeter</li>
<li>Fluke 27 II Rugged Digital Multimeter</li>
<li>Fluke 28 II Ex Intrinsically Safe True RMS Digital Multimeter</li>
<li>Fluke 28 II Rugged Digital Multimeter</li>
<li>Fluke 287 True-RMS Electronics Logging Multimeter</li>
<li>Fluke 289 True-RMS Data Logging Multimeter</li>
<li>Fluke 3000 FC Series Wireless Multimeter</li>
<li>Fluke 77 IV Digital Multimeter</li>
<li>Fluke 787 ProcessMeter Digital Multimeter</li>
<li>Fluke 787B ProcessMeter™</li>
<li>Fluke 789 ProcessMeter™</li>
<li>Fluke 83V Average Responding Industrial Multimeter</li>
<li>Fluke 87V Industrial Multimeter</li>
<li>Fluke 87V MAX True-RMS Digital Multimeter</li>
<li>Fluke 88V Deluxe Automotive Multimeter</li>
<li>Fluke BT508 Battery Analyzer</li>
<li>Fluke BT510 Basic Battery Analyzer</li>
<li>Fluke BT521 Advanced Battery Analyzer</li>
</ul>
</li>
</ul>
<p>The post <a href="https://rapid-tech.com.au/fluke-440ma-1000v-fuse-dmm-44-100a/">Fluke 440mA 1000V Fuse | DMM 44/100A</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 11A 1000V Fuse &#124; DMM-11A</title>
		<link>https://rapid-tech.com.au/fluke-11a-1000v-fuse-dmm-11a/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Fri, 28 May 2021 05:26:16 +0000</pubDate>
				<guid isPermaLink="false">https://fluke-test.com.au/?post_type=product&#038;p=1358</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-679" src="https://rapid-tech.com.au/wp-content/uploads/2020/07/Fluke-Logo-Small.png" alt="" width="200" height="67" /></p>
<p><a target="_blank" href="https://mymeter.com.au/product/fluke-11a-1000v-fuse-dmm-11a/" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<h3>Fluke 11A 1000V fuse &#124; DMM-11A</h3>
<h4>Features:</h4>
<ul>
<li style="list-style-type: none;">
<ul>
<li><strong>11 amp, 1000 volt fuse</strong> for Fluke digital multimeters</li>
<li><strong>High-energy, fast-release fuse</strong> designed measuring current</li>
<li>Sand-filled to reduce risk of breakage during current overloads</li>
</ul>
</li>
</ul>
<section id="fluke-product-atf-ctas" class="">
<section id="fluke-product-alerts"></section>
<div id="product-model-price"></div>
</section>
<p>The post <a href="https://rapid-tech.com.au/fluke-11a-1000v-fuse-dmm-11a/">Fluke 11A 1000V Fuse | DMM-11A</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Fluke 11A 1000V Fuse | DMM-11A</h3>
<p>This<strong> high-energy fuse</strong> is designed to <strong>protect a user from electric shock and burns.</strong> It does this by keeping the energy generated by an electrical short within the fuse enclosure.</p>
<p>The fuse is <strong>built to limit the length of time the energy</strong> is applied and the amount of oxygen available for combustion.</p>
<p>The fuse is filled with sand to stop an electrical short. The sand will not only h<strong>elp absorb the shock energy created by the current overload</strong>, but also help with the high temperatures generated (up to 10,000 °F).</p>
<p>The energy will melt the sand and turn it to glass,<strong> helping smother a potential fireball</strong> by cutting off the available oxygen, further protecting the user.</p>
<h4>The Fluke 11A 1000V fuse is used in the following Fluke Digital Multimeters</h4>
<ul>
<li style="list-style-type: none;">
<ul>
<li>Fluke 107 Palm-sized, CAT III Digital Multimeter</li>
<li>Fluke 115 Field Technicians Digital Multimeter</li>
<li>Fluke 117 Electrician&#8217;s Multimeter with Non-Contact Voltage</li>
<li>Fluke 177 True-RMS Digital Multimeter</li>
<li>Fluke 179 True-RMS Digital Multimeter</li>
<li>Fluke 233 Remote Display Digital Multimeter</li>
<li>Fluke 27 II Rugged Digital Multimeter</li>
<li>Fluke 287 True-RMS Electronics Logging Multimeter</li>
<li>Fluke 289 True-RMS Data Logging Multimeter</li>
<li>Fluke 28 II Rugged Digital Multimeter</li>
<li>Fluke 28 II Ex Intrinsically Safe True RMS Digital Multimeter</li>
<li>Fluke 77 IV Digital Multimeter</li>
<li>Fluke 83V Average Responding Industrial Multimeter</li>
<li>Fluke 87V Industrial Multimeter</li>
<li>Fluke 87V MAX True-RMS Digital Multimeter</li>
<li>Fluke 88V Deluxe Automotive Multimeter</li>
</ul>
</li>
</ul>
<p>The post <a href="https://rapid-tech.com.au/fluke-11a-1000v-fuse-dmm-11a/">Fluke 11A 1000V Fuse | DMM-11A</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
