FLIR SV87 Vibration/Temperature Remote Sensor Specifications
Measurements | Acceleration: ± 32 g (gravitational constant) Velocity data (mm/s or in/s) displayed in the mobile and Windows apps, derived from FFT. Contact temperature trend range: –30℃ ~+80℃) | |
Frequency Range | 10 Hz ~ 1 kHz | |
Sampling rate | One data point captured / 90 seconds | |
Sensor attachment method | Double-sided tape (supplied). Order Tesa® 4957 double- sided general purpose PE-foam tape from your local sup- plier for additional tape. Adhesive alternatives are available on the market that could be more reliable on some machinery. Epoxy (Loctite AA 330 + Loctite SF 7387/8) may give a more rigid and long lasting bond. | |
Number of sensors per Gateway | Ten (10) sensors will work in most circumstances, given no obstruction between Gateway and sensor. The key factor is obstruction since, with no obstruction, it is possible to have more than ten sensors operating normally. | |
Operating Temperature | -30 ℃ ~ +80 ℃ | |
Operating altitude | 2000 metres | |
Battery | 3.6 V 2400 mAh Lithium battery (battery life: 4 years, nominal) | |
Bluetooth | Type: | BLE 4.2 |
Sensor-to-Gateway Range: | 213 ft. (65 m) line-of-sight | |
Output power: | < 10 mW | |
IP Rating | IP 67 | |
Drop-proof | 1 metre | |
Safety | Certifications: ETL / IC / FCC / CE / RCM | |
Dimensions | 61.5 mm x 24 mm | |
Weight | 28 g |