<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>EMC Scanners Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/emc-scanners/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/emc-scanners/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Mon, 15 Sep 2025 04:39:07 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.10</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>EMC Scanners Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/emc-scanners/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>The Pendulum/Detectus EMC-Scanners -&#124; HRE series</title>
		<link>https://rapid-tech.com.au/the-pendulum-detectus-emc-scanners-hre-series/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Fri, 02 Sep 2022 06:06:18 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=23060</guid>

					<description><![CDATA[<p><img class="alignnone wp-image-22048" src="https://rapid-tech.com.au/wp-content/uploads/2022/04/pendulum-instruments-logo.png" alt="pendulum logo" width="217" height="58" /></p>
<p>The Pendulum/Detectus HRE series EMC Pre-Compliance Scanners are the perfect cost-effective tools for measuring and analyzing ElectroMagnetic Interference (EMI).</p>
<p>With their powerful 4D scanning capabilities, they can take high-resolution scans of radiation down to 25 μm steps, and up to 10 GHz frequency range. Even inside an IC, the HRE series provides outstanding easy-to-use scanning software for visualization and documentation.</p>
<p>With their repetitive high-resolution scanning, the HRE series is the perfect pre-compliance tool for any engineer looking to get the most out of their measurements.</p>
<h4><img class="alignnone wp-image-19718 size-full" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" />  <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2022/09/Detectus-HRE-series-v4-27-06-22.pdf" rel="noopener">Pendulum/Detectus HRE series Datasheet</a></h4>
<p>The post <a href="https://rapid-tech.com.au/the-pendulum-detectus-emc-scanners-hre-series/">The Pendulum/Detectus EMC-Scanners -| HRE series</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>SCN series EMC Scanners are the new industry standard for EMC scanning, with 2D or 4D options.</h2>
<p>Pendulum&#8217;s DETECTUS EMC-Scanners are high-resolution, affordable scanners that come in three different sizes to fit most DUTs. They combine very-high scan resolution of 0.1 mm with probe head rotation, and the best-in-class scanning software to deliver powerful visualization of the EMC test.</p>
<p>For boards with components of substantially different heights, the optional laser distance meter will enable you to follow the DUT&#8217;s topography and measure at a fixed distance from the DUT, automatically creating a precise 3D-model of the DUT. With Pendulum&#8217;s DETECTUS EMC-Scanners, you&#8217;ll be able to quickly and easily identify any potential problems with your product&#8217;s electromagnetic compatibility, ensuring that it meets all applicable standards.</p>
<p>The Pendulum Detectus EMC-Scanners are a complete scanner system that can be used to test the field strength of an object. The system consists of the EMC-Scanner Hardware package, the Detectus Scanning SW (DSS), a Spectrum Analyzer, and a PC to run the scanner SW.</p>
<p>The object to be tested is placed on the coordinate board, and a small near-field probe is moved in a controlled and repeatable path above the test object, registering the field strength. The probe output signal in every position is measured by the Spectrum Analyzer, and transferred to the scanner SW. The smart SW combines the spatial information (X,Y,Z) with the spectrum in that position, and presents detailed results.</p>
<h3>Leading Performance from the Detectus designers</h3>
<p>With 25 μm step size of the scanner, you can pinpoint emission sources in densely packed designs. You can even follow emission hot spots inside an IC, using the IC option</p>
<p>You can scan emissions up to 10 GHz, with the standard Pendulum Probe kits. If the user has near-field probes going up to higher frequencies, e.g. 70 GHz, these can normally be attached and used for EMC-scanning. The SW has no limits, but you must of course use a Spectrum Analyzer that support the frequency range.</p>
<p><strong>Within the Detectus HRE series you can choose from two different sizes, with or without probe rotation, to fit most test objects. The scan area (WxDxH) is:</strong></p>
<ul>
<li>280x180x85mm (3D or 4D*)</li>
<li>390x290x130 mm (3D or 4D*)</li>
</ul>
<p><em>* 4D = 3D xyz movement, plus probe rotation 0 to 360<sup>o</sup></em></p>
<figure id="attachment_23062" aria-describedby="caption-attachment-23062" style="width: 798px" class="wp-caption alignnone"><img fetchpriority="high" decoding="async" class="wp-image-23062 size-full" src="https://rapid-tech.com.au/wp-content/uploads/2022/09/Comparative_measurements_decoupling-1.jpg" alt="Comparative measurements of EMI for six different IC de-coupling capacitor alternatives" width="798" height="550" srcset="https://rapid-tech.com.au/wp-content/uploads/2022/09/Comparative_measurements_decoupling-1.jpg 798w, https://rapid-tech.com.au/wp-content/uploads/2022/09/Comparative_measurements_decoupling-1-300x207.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2022/09/Comparative_measurements_decoupling-1-768x529.jpg 768w, https://rapid-tech.com.au/wp-content/uploads/2022/09/Comparative_measurements_decoupling-1-600x414.jpg 600w" sizes="(max-width: 798px) 100vw, 798px" /><figcaption id="caption-attachment-23062" class="wp-caption-text"><em>Comparative measurements of EMI for six different IC de-coupling capacitor alternatives</em></figcaption></figure>
<h3><strong>Advantages of the Detectus HRE scanner</strong></h3>
<h4><strong><em>In R&amp;D</em></strong></h4>
<p>Using the EMC-Scanner during the early stages of design enables you to detect potential emission and immunity problems before they become integrated into the product and expensive to correct.</p>
<p>If a product has failed a test at a test house, normally you only learn which frequency failed, not the location of the noise source. The EMC-Scanner can help you find the source, and repeated measurements while redesigning your product helps you lower the emission levels.</p>
<p>Similarly, if your problem was immunity, you can (optionally) scan for sensitive areas and repeat measurements while strengthening your product.</p>
<p>You can compare different design solutions and make comparative measurements of electromagnetic emissions. You can even analyze the EMI-noise inside an IC or a compact module, thanks to the ultra-high-resolution step size (25 μm)</p>
<h4><strong><em>In Q&amp;A</em></strong></h4>
<p>The EMC-Scanner can help you maintain a high quality in the production line. You can make measurements on samples from the production line and easily compare them with a reference. That way you can make sure that, for example, a change of supplier of a component doesn’t affect the emission spectra in a negative way.</p>
<h3><strong>World class SW lets you SEE electromagnetic fields</strong></h3>
<p>The easy-to-use and feature-rich DSS SW let you measure and visualize the intensity and the location of a radiation source at a component level – or even inside a component. The results of such a measurement can be shown as two- or three-dimensional colored maps. The measurements can easily be repeated creating objective, comparative measurement results.</p>
<p>Measurements can be saved and later compared with board-level changes, thanks to the exact repetitive scanning. The SW even allows to subtract two scanning results to emphasize the true difference of any board layout – or component – change.</p>
<p>The post <a href="https://rapid-tech.com.au/the-pendulum-detectus-emc-scanners-hre-series/">The Pendulum/Detectus EMC-Scanners -| HRE series</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>The Pendulum/Detectus EMC-Scanners -&#124; SCN series</title>
		<link>https://rapid-tech.com.au/the-pendulum-detectus-emc-scanners-scn-series/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Fri, 02 Sep 2022 05:19:35 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=23054</guid>

					<description><![CDATA[<p><img class="alignnone wp-image-22048" src="https://rapid-tech.com.au/wp-content/uploads/2022/04/pendulum-instruments-logo.png" alt="pendulum logo" width="217" height="58" /></p>
<p>The Pendulum SCN-500 series of EMC-Scanners are powerful and affordable pre-compliance tools for measurement and analysis of ElectroMagnetic Interference (EMI).</p>
<p>The models in the SCN series feature repetitive high-resolution on 4D (3D movement plus rotation of the probe head) scanning of radiation, down to 100 μm steps, and up to 10 GHz frequency range, with an outstandingly powerful, yet easy-to-use, scanning SW for visualization and documentation.</p>
<h4><img class="alignnone wp-image-19718 size-full" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" />  <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2022/09/SCN-500-data-sheet.pdf" rel="noopener">The Pendulum/Detectus SCN-500 series Datasheet</a></h4>
<p>The post <a href="https://rapid-tech.com.au/the-pendulum-detectus-emc-scanners-scn-series/">The Pendulum/Detectus EMC-Scanners -| SCN series</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>SCN series EMC Scanners are the new industry standard for EMC scanning, with 2D or 4D options.</h2>
<p>Pendulum&#8217;s DETECTUS EMC-Scanners are high-resolution, affordable scanners that come in three different sizes to fit most DUTs. They combine very-high scan resolution of 0.1 mm with probe head rotation, and the best-in-class scanning software to deliver powerful visualization of the EMC test.</p>
<p>For boards with components of substantially different heights, the optional laser distance meter will enable you to follow the DUT&#8217;s topography and measure at a fixed distance from the DUT, automatically creating a precise 3D-model of the DUT. With Pendulum&#8217;s DETECTUS EMC-Scanners, you&#8217;ll be able to quickly and easily identify any potential problems with your product&#8217;s electromagnetic compatibility, ensuring that it meets all applicable standards.</p>
<p>The Pendulum Detectus EMC-Scanners are a complete scanner system that can be used to test the field strength of an object. The system consists of the EMC-Scanner Hardware package, the Detectus Scanning SW (DSS), a Spectrum Analyzer, and a PC to run the scanner SW.</p>
<p>The object to be tested is placed on the coordinate board, and a small near-field probe is moved in a controlled and repeatable path above the test object, registering the field strength. The probe output signal in every position is measured by the Spectrum Analyzer, and transferred to the scanner SW. The smart SW combines the spatial information (X,Y,Z) with the spectrum in that position, and presents detailed results.</p>
<h3>Leading Performance from the Detectus designers</h3>
<p>With 0.1mm step size of the scanner, you can pinpoint emission sources in densely packed designs, at comparable cost to 1mm scanners</p>
<p>You can scan emissions up to 10 GHz, with the standard Pendulum Probe kits. If the user has near-field probes going up to higher frequencies, e.g. 70 GHz, then these can easily be attached and used for EMC-scanning. The SW has no limits, but you must of course use a Spectrum Analyzer that supports the frequency range.</p>
<p><strong>Within the Detectus SCN series you can choose from various sizes, to fit most test objects. The scan table comes in four basic sizes (WxDxH):</strong></p>
<ul>
<li>200×100 mm (2D scanning without Z-axis and probe rotation)</li>
<li>200x100x100 mm (4D = 3D scanning with probe rotation)</li>
<li>300x200x100 mm (4D = 3D scanning with probe rotation)</li>
<li>600x400x300 mm (4D = 3D scanning with probe rotation)</li>
</ul>
<figure id="attachment_23062" aria-describedby="caption-attachment-23062" style="width: 798px" class="wp-caption alignnone"><img decoding="async" class="wp-image-23062 size-full" src="https://rapid-tech.com.au/wp-content/uploads/2022/09/Comparative_measurements_decoupling-1.jpg" alt="Comparative measurements of EMI for six different IC de-coupling capacitor alternatives" width="798" height="550" srcset="https://rapid-tech.com.au/wp-content/uploads/2022/09/Comparative_measurements_decoupling-1.jpg 798w, https://rapid-tech.com.au/wp-content/uploads/2022/09/Comparative_measurements_decoupling-1-300x207.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2022/09/Comparative_measurements_decoupling-1-768x529.jpg 768w, https://rapid-tech.com.au/wp-content/uploads/2022/09/Comparative_measurements_decoupling-1-600x414.jpg 600w" sizes="(max-width: 798px) 100vw, 798px" /><figcaption id="caption-attachment-23062" class="wp-caption-text"><em>Comparative measurements of EMI for six different IC de-coupling capacitor alternatives</em></figcaption></figure>
<h3><strong>Advantages of the Detectus SCN scanner</strong></h3>
<h4><strong>In R&amp;D</strong></h4>
<p>Using the EMC-Scanner during the early stages of design enables you to detect potential emission and immunity problems before they become integrated into the product and expensive to correct.</p>
<p>If a product has failed a test at a test house, normally you only learn which frequency failed, not the location of the noise source. The EMC-Scanner can help you find the source, and repeated measurements while redesigning your product helps you lower the emission levels.</p>
<p>Similarly, if your problem was immunity, you can (optionally) scan for sensitive areas and repeat measurements while strengthening your product.</p>
<p>You can compare different design solutions and make comparative measurements of electromagnetic emissions.</p>
<h4><strong>In Q&amp;A</strong></h4>
<p>The EMC-Scanner can help you maintain a high quality in the production line. You can make measurements on samples from the production line and easily compare them with a reference. That way you can make sure that, for example, a change of supplier of a component doesn’t affect the emission spectra in a negative way.</p>
<p>&nbsp;</p>
<h3><strong>World class SW lets you SEE electromagnetic fields</strong></h3>
<p>The easy-to-use and feature-rich DSS SW let you measure and visualize the intensity and the location of a radiation source at a component level – or even inside a component. The results of such a measurement can be shown as two- or three-dimensional colored maps. The measurements can easily be repeated creating objective, comparative measurement results.</p>
<p>Measurements can be saved and later compared with board-level changes, thanks to the exact repetitive scanning. The SW even allows to subtract two scanning results to emphasize the true difference of any board layout – or component – change.</p>
<p>The post <a href="https://rapid-tech.com.au/the-pendulum-detectus-emc-scanners-scn-series/">The Pendulum/Detectus EMC-Scanners -| SCN series</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
