<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Electrical Testers Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/electrical-testers-ht-italia/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/electrical-testers-ht-italia/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Mon, 03 Aug 2026 04:32:43 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.7</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>Electrical Testers Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/electrical-testers-ht-italia/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>HTI EV-TEST100 EVSE Adapter for Electric Vehicle Charger Testing</title>
		<link>https://rapid-tech.com.au/hti-ev-test100-evse-adapter-for-electric-vehicle-charger-testing/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Fri, 25 Sep 2020 07:09:21 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=16640</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/10/HTI-Auth-Med.jpg"><img class="alignnone size-full wp-image-5688" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/HTI-Auth-Med.jpg" alt="" width="165" height="120" /></a></p>
<p>The EV-TEST100 is a 1- and 3-phase test adapter with type 2 connector for simulation of charge levels and to check the effectiveness of protective measures at e-charging stations for electric cars (EVSE systems - Electrical Vehicle Supply Equipment)</p>
<p>The EV-TEST100 in combination with appropriate HT multifunction instrument simulates an electric vehicle connected to the charging station, allowing you to verify the EVSE full functionality and electrical safety.</p>
<p>EV-TEST100 is able to test charging stations with charging modes 2 and 3 and Type 2 connector (European standard).</p>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/hti-ev-test100-evse-adapter-for-electric-vehicle-charger-testing/">HTI EV-TEST100 EVSE Adapter for Electric Vehicle Charger Testing</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3 style="text-align: center;">HTI EV-TEST100 EVSE Adapter for Electric Vehicle Charger Testing<br />
<iframe src="https://www.youtube.com/embed/EPVzSR1h_MQ" width="506" height="285" frameborder="0" allowfullscreen="allowfullscreen"></iframe></h3>
<div>The EV-Test100 was specially developed as an accessory for testing e-charging stations.</div>
<div>It can be used to simulate charge states and to check the effectiveness of protective measures at type 3 e-charging stations with a type 2 connector.</div>
<div>The simple handling in combination with the Combi G3 or Combi G2 is guaranteed.</div>
<h3>Measurement functions</h3>
<ul>
<li>Universal 4mm sockets for connection to a 1- or 3-phase installation tester using test leads (banana plugs)</li>
<li>Separate phase display with three LEDs for easy voltage checking</li>
<li>Proximity Pilot (PP) rotary switch for simulating different current carrying capacities of charging cables</li>
<li>Control Pilot (CP) rotary switch for simulating the electrical vehicle status A, B, C D</li>
<li>Rotary switch error to simulate a short circuit between CP and PE (state E = error)</li>
<li>Simulation of PE fault (ground fault)</li>
<li>Connection for the CP signal output to check communication between the adapter (= simulated electric vehicle) and the charging station</li>
<li>Type 2 plug for connection to the charging station even with a permanently connected charging cable</li>
<li>Vehicle simulation (CP): The various vehicle states A to D can be simulated using a rotary switch (according to IEC 61851)</li>
<li>Cable simulation (PP): The various codings for charging cables with 13, 20, 32 and 63 A as well as “no cable connected” can be simulated using a rotary switch</li>
<li>Error simulation: Simulation of a short circuit between CP and PE using a rotary switch (state E = error)</li>
<li>Display of phase voltages via LEDs</li>
<li>Testing of e-charging stations even with a permanent</li>
<li>connected charging cable</li>
<li>For vehicle simulation (CP):</li>
</ul>
<h4><strong>According to IEC 61851, the states A, B, C, D and E can be simulated. The various vehicle states are set using the rotary switch.</strong></h4>
<div style="padding-left: 40px;">State A: no vehicle connected</div>
<div style="padding-left: 40px;">Condition B: Vehicle connected but not ready for charging</div>
<div style="padding-left: 40px;">Condition C: Vehicle connected and ready for charging, ventilation of the charging area not required</div>
<div style="padding-left: 40px;">Condition D: Vehicle connected and ready for charging, ventilation of the charging area required</div>
<div style="padding-left: 40px;">State E: Error: Short circuit CP-PE via internal diode</div>
<div></div>
<div><strong>For cable simulation (PP):</strong></div>
<div>The different coding for charging cables with 13, 20, 32 and 63 A can be simulated. It is also possible to simulate the -no cable- state. The different charging cables are simulated by switching different resistors between PP and PE using the rotary switch. According to IEC 61851, the following values ​​are possible:</div>
<div></div>
<div style="padding-left: 40px;">No cable: ∞ Ohm</div>
<div style="padding-left: 40px;">13 A cable: 1.5 k Ohm</div>
<div style="padding-left: 40px;">20 A cable: 680 Ohm</div>
<div style="padding-left: 40px;">32 A cable: 220 Ohm</div>
<div style="padding-left: 40px;">63 A cable. 100 ohms</div>
<div></div>
<div class="pg-opt prodotti">
<div class="container-fluid">
<div class="row">
<div class="col-md-12 bg-greyprod">
<section class="slice ">
<div class="container">
<div class="tab-content">
<div id="tab-2" class="tab-pane fade active in">
<div class="tab-body prodotti">
<h3 class="titlethin funz">HTI EV-TEST100 Functions</h3>
<div class="list-check">
<table border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i> Use for EVSE charging stations</td>
<td class="description">Charging modes 2 and 3</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Test cable with connector</td>
<td class="description">Type 2 (IEC 62196-2)</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Vehicle simulation via Control Pilot (CP state)</td>
<td class="description">States A, B, C, D</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Simulating the current capacity of Proximity Pilot (PP state)</td>
<td class="description">NC, 13A, 30A, 32A, 63A</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Fault condition simulation on PE</td>
<td class="description">FAULT PE</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Diode simulation in short circuit</td>
<td class="description">FAULT E</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>EVSE internal counter efficiency check</td>
<td class="description">LOAD</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Input voltage</td>
<td class="description">Max 415V AC, Phase-Phase, 50 / 60Hz</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>External load L-N-PE</td>
<td class="description">240V 50/60Hz, Max 10A AC</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>CP signal</td>
<td class="description">PWM 12V</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>External load protection</td>
<td class="description">Fuse FF 10A / 250V, 5x20mm</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Operating temperature</td>
<td class="description">0°C ÷ 40°C</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Operating humidity</td>
<td class="description">&lt;80&amp;RH</td>
</tr>
</tbody>
</table>
</div>
<h4 class="titlethin norm">Guidelines</h4>
<div class="row">
<div class="col-sx-12 col-md-12 col-lg-12">
<div class="col-sx-12 col-md-12 col-lg-12 nopadding_right nopadding_left">
<ul>
<li><i class="fa fa-check"></i> IEC/EN60364-7-722</li>
</ul>
</div>
<div class="col-sx-12 col-md-12 col-lg-12 nopadding_right nopadding_left">
<ul>
<li><i class="fa fa-check"></i> IEC/EN61010-1</li>
</ul>
</div>
<div class="col-sx-12 col-md-12 col-lg-12 nopadding_right nopadding_left">
<ul>
<li> IEC/EN61851-1</li>
</ul>
</div>
<h4>EV-TEST100 can only be used in combination with the following master models of the HT family</h4>
<p style="padding-left: 40px;">COMBI G3 MET-5035M<br />
COMBIG2 COMBIG2PLUS<br />
MACROTOUCH<br />
COMBITEST425<br />
MT-300<br />
MFT-PRO<br />
COMBITOUCH<br />
COMBIG3<br />
<span style="font-size: 85%;">(*) The list of available models is subject to change without notice. </span></p>
</div>
</div>
</div>
</div>
</div>
</div>
</section>
</div>
</div>
</div>
</div>
<p>The post <a href="https://rapid-tech.com.au/hti-ev-test100-evse-adapter-for-electric-vehicle-charger-testing/">HTI EV-TEST100 EVSE Adapter for Electric Vehicle Charger Testing</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HT Instruments FULLTEST3 Professional Multifunction Safety Tester</title>
		<link>https://rapid-tech.com.au/ht-instruments-fulltest3-professional-multifunction-safety-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Fri, 28 Aug 2020 02:34:17 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=16399</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/10/HTI-Auth.jpg"><img class="alignnone size-full wp-image-5689" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/HTI-Auth.jpg" alt="" width="220" height="160" /></a></p>
<p><a target="_blank" href="https://mymeter.com.au/product/ht-instruments-fulltest3-professional-multifunction-safety-tester" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<p>[button size="medium" style="secondary" text="<b>RENT BEFORE YOU BUY</b>" link="https://rentmymeter.com.au/product/ht-instruments-fulltest3-professional-multifunction-safety-tester/" target="blank"]</p>
<p><span style="font-size: 110%;"><strong>The HT Instruments FULLTEST3 effects all tests required by IEC/EN60204-1:2006 and IEC/EN61439 in a simple, reliable and fast way.</strong></span></p>
<p>The FULLTEST3 also carries out a considerable number of safety tests that makes it as a flexible solution also in compliance with other standards.</p>
<p>Besides continuity of protection conductors, insulation and withstanding, FULLTEST3 tests type A, AC, and B general, selective and delayed RCDs, curve B, C, D, and K MCBs and type gG and aM fuses, line/fault impedance with standard or high resolution, non-trip earth loop impedance, leakage current, etc.</p>
<p>FULLTEST3 is provided with innovative interfaces such as a colour touch-screen graphical display, 3 USB ports for PC connection, a USB memory stick, a USB printer and bar code readers.</p>
<p style="text-align: center;"><span style="font-size: 110%;"><strong>The FULLTEST3 is the ideal partner for designers, manufacturers and installers.</strong></span></p>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST3-Datasheet.pdf" rel="noopener">HT FULLTEST3 Datasheet</a></span></h3>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST3-Brochure.pdf" rel="noopener">HT FULLTEST3 Brochure</a></span></h3>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST3-User-Manual.pdf" rel="noopener">HT FULLTEST3 User Manual</a></span></h3>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/ht-instruments-fulltest3-professional-multifunction-safety-tester/">HT Instruments FULLTEST3 Professional Multifunction Safety Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><b>FULLTEST 3 is the Most Advanced Solution for a Complete Compliance with the Actual Guidelines</b></p>
<div class="epyt-video-wrapper"><iframe  id="_ytid_80442"  width="1020" height="574"  data-origwidth="1020" data-origheight="574"  data-relstop="1" src="https://www.youtube.com/embed/alEBhWBmBJA?enablejsapi=1&#038;autoplay=0&#038;cc_load_policy=0&#038;cc_lang_pref=&#038;iv_load_policy=1&#038;loop=0&#038;rel=0&#038;fs=1&#038;playsinline=1&#038;autohide=2&#038;theme=dark&#038;color=red&#038;controls=1&#038;disablekb=0&#038;" class="__youtube_prefs__  epyt-is-override  no-lazyload" title="HT FULLTEST3 Tutorials - Prova di Rigidità Dielettrica fino a 5100VAC (ITA)"  allow="fullscreen; accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen data-no-lazy="1" data-skipgform_ajax_framebjll=""></iframe></div>
<p>Multifunction Tester for safety of machinery IEC/EN60204-1:2016 and low voltage switchgears and controlgears IEC/EN61439-1-2:2011</p>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST5-Front-Panel.jpg"><img fetchpriority="high" decoding="async" class="aligncenter wp-image-16402" src="https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST5-Front-Panel-300x213.jpg" alt="" width="500" height="355" srcset="https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST5-Front-Panel-300x213.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST5-Front-Panel-600x425.jpg 600w, https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST5-Front-Panel-768x545.jpg 768w, https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST5-Front-Panel.jpg 1000w" sizes="(max-width: 500px) 100vw, 500px" /></a></p>
<p><strong>IEC/EN60204-1:2016 Measuments:</strong></p>
<p><strong>Power Frequency Dielectric withstand voltage</strong> with test voltage of <strong>1000VAC</strong></p>
<p><strong>Testing protection against indirect contact:</strong></p>
<ul>
<li>Continuity of protective conductors with test current 200mA</li>
<li>Automatic disconnection of the supply (RCD, MCB, Fuse)​</li>
<li>RCD tripping (RCD AC, A, B) up to 1A on TT Systems</li>
<li>Magneto-thermal protections (MCB curve verificaiton on B, C, D, K) and fuses (gG, aM) on TN Systems</li>
</ul>
<p><strong>​Insulation resistance measurement with test voltage of 500VDC</strong></p>
<p><strong>Discharging of residual voltage V&lt;60V in 5sec/1sec</strong></p>
<p><strong>IEC/EN61439-1-2:2011 Measurements:</strong></p>
<p><strong>Clearances and Creepage distances:</strong></p>
<ul>
<li>Dielectric withstand voltage with test voltage of up to 3400/5100VAC</li>
</ul>
<p><strong>Continuity of earth system and protective conductors</strong> ≥10A</p>
<p><strong>Power Frequency Dielectric withstand voltage</strong> with test voltage of <strong>1800VAC</strong></p>
<p><strong>Alternative power-frequency voltage test up to 5100VAC</strong></p>
<p><strong>Test on enclosures of insulating material:</strong></p>
<ul>
<li><strong>​</strong>Dielectric Withstand voltage with test voltage up to <strong>2835V</strong></li>
</ul>
<p><strong>Discharging of residual voltage V&lt;60V in 5sec/1sec</strong></p>
<p>FULLTEST3 is designed to satisfy the requirements of the IEC/EN60204-1:2006 guideline (electrical equipment of industrial machines) and for the new series of prescriptions relative to the IEC/EN61439-1 guideline (Switchgear panels). This last guideline require, among other tests, the Dielectric tests with a test voltage up to 5100V!</p>
<h3><strong>FULLTEST3 Features:</strong></h3>
<ul>
<li>Continuity of protection conductors with 200mA</li>
<li>Continuity of protection conductors with I&gt;10A, V&lt;12V AC</li>
<li>Continuity of protection conductors with I&gt;25A, V&lt;12V AC</li>
<li>Insulation Resistance with 100,250,500,1000VDC test voltage</li>
<li>Withstanding test with test voltage programmable from 250V to 5100V AC</li>
<li>Discharging time test on internal capacitance and on power supply plug</li>
<li>Leakage/absorbed and power on the test socket</li>
<li>Leakage current with external clamp (HT96U optional accessories)</li>
<li>Test on RCDs type A, AC, B General, Selective, Delayed up to 1000mA</li>
<li>Line/Loop impedance and Ipsc calculation</li>
<li>Line/Loop impedance with high resolution (with IMP57 optional accessories)</li>
<li>Test on MCB protection with curve B, C, D, K and Fuse type gG and aM</li>
<li>Selection of length, cable type, insulation of cable, tripping time of protection device</li>
<li>Global earth resistance without RCD tripping</li>
<li>Phase sequence indication</li>
<li>TFT display with touch-screen</li>
<li>Programmable timer on tests</li>
<li>Programmable thresholds on measurement</li>
<li>Internal memory</li>
<li>USB interface for PC connection</li>
<li>USB interface for keyboard, printer and barcode reader connection</li>
</ul>
<h3>Test to Guidelines:</h3>
<div class="col-sx-12 col-md-12 col-lg-12 nopadding_right nopadding_left">
<ul>
<li><i class="fa fa-check"></i> CEI 64-8</li>
<li><i class="fa fa-check"></i> CEI 64-8/7</li>
<li><i class="fa fa-check"></i> CE MARK</li>
<li><i class="fa fa-check"></i> EMC 2014/30/EU</li>
<li><i class="fa fa-check"></i> EMC: IEC/EN61326</li>
<li><i class="fa fa-check"></i> EN50106</li>
<li><i class="fa fa-check"></i> IEC/EN60204-1</li>
<li><i class="fa fa-check"></i> IEC/EN60598-1</li>
<li><i class="fa fa-check"></i> IEC/EN61010-1</li>
<li><i class="fa fa-check"></i> IEC/EN61187</li>
<li><i class="fa fa-check"></i> IEC/EN61335-1</li>
<li><i class="fa fa-check"></i> IEC/EN61439-1</li>
<li><i class="fa fa-check"></i> IEC/EN61439-2</li>
<li><i class="fa fa-check"></i> IEC/EN61557-1</li>
<li><i class="fa fa-check"></i> IEC/EN61557-13</li>
<li><i class="fa fa-check"></i> IEC/EN61557-14</li>
<li><i class="fa fa-check"></i> IEC/EN61557-2</li>
<li><i class="fa fa-check"></i> IEC/EN61557-3</li>
<li><i class="fa fa-check"></i> IEC/EN61557-4</li>
<li><i class="fa fa-check"></i> IEC/EN61557-6</li>
<li><i class="fa fa-check"></i> IEC/EN61557-7</li>
<li><i class="fa fa-check"></i> LVD 2014/35/EU</li>
<li><i class="fa fa-check"></i> UNE20460</li>
</ul>
</div>
<h3>Standard Accessories:</h3>
<ul>
<li>Australian Power cord</li>
<li>Test cable red, 3 metre, 2 pcs</li>
<li>Test cable blue, 3 metre</li>
<li>Test cable green, 3 metre</li>
<li>C2033X : Cable 3 wires with Shuko plug</li>
<li>Cable with 5kV safety, 2 pcs</li>
<li>Test lead CAT III, 3 pcs</li>
<li>Test lead CAT II, 3 pcs</li>
<li>Alligator clip, 3pcs</li>
<li>TOPVIEW2007 : Windows software + USB cable C2007</li>
<li>Carry bag for accessories</li>
<li>ISO9000 calibration certificate</li>
</ul>
<h3>Optional Accessories:</h3>
<ul>
<li>IMP57 : Accessory for high resolution Loop/Line Impedance</li>
<li>HT96U : Rigid clamp 1-100-1000A AC, diameter 54mm</li>
</ul>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST3-Accesories-banner.jpg"><img loading="lazy" decoding="async" class="aligncenter wp-image-16404 size-large" src="https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST3-Accesories-banner-1024x283.jpg" alt="" width="1020" height="282" srcset="https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST3-Accesories-banner-1024x283.jpg 1024w, https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST3-Accesories-banner-300x83.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST3-Accesories-banner-600x166.jpg 600w, https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST3-Accesories-banner-768x213.jpg 768w, https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST3-Accesories-banner.jpg 1250w" sizes="auto, (max-width: 1020px) 100vw, 1020px" /></a></p>
<p>The post <a href="https://rapid-tech.com.au/ht-instruments-fulltest3-professional-multifunction-safety-tester/">HT Instruments FULLTEST3 Professional Multifunction Safety Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HT Instruments NEPTUNE Multimeter/Insulation Tester</title>
		<link>https://rapid-tech.com.au/ht-instruments-neptune-multimeter-insulation-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Wed, 19 Jun 2019 03:54:54 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=11983</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-5688" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/HTI-Auth-Med.jpg" alt="" width="165" height="120" /></p>
<p><a target="_blank" href="https://mymeter.com.au/product/ht-instruments-neptune-multimeter-insulation-tester/" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<h4>HT Instruments NEPTUNE Features:</h4>
<ul>
<li><span style="font-size: 90%;">Autorange function &#38; automatic detection of AC, DC for all measurements.</span></li>
<li><span style="font-size: 90%;">Insulation test voltages of 50,100,250,500,1000VDC</span></li>
<li><span style="font-size: 90%;">DC, AC TRMS, AC+DC TRMS voltage up to 1000V.</span></li>
<li><span style="font-size: 90%;">Low-impedance LoZ input to eliminate “stray voltages” from the measurement</span></li>
<li><span style="font-size: 90%;">DC, AC TRMS, AC+DC TRMS current by means of an optional external current clamp</span></li>
<li><span style="font-size: 90%;">Measurement of voltage or current frequency.</span></li>
<li><span style="font-size: 90%;">Resistance and continuity with buzzer.</span></li>
<li><span style="font-size: 90%;">MAX/MIN/PEAK/HOLD functions.</span></li>
<li><span style="font-size: 90%;"> CAT IV 600V, CAT III 1000V Safety Rating</span></li>
<li><span style="font-size: 90%;">ISO 9000 Calibration Certificate included</span></li>
<li><span style="font-size: 90%;">Similar to the Fluke 1587 &#38; Fluke 1577</span></li>
</ul>
<p><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" />    <a href="https://rapid-tech.com.au/wp-content/uploads/2019/06/NEPTUNE-Datasheet.pdf">NEPTUNE Datasheet</a></p>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/ht-instruments-neptune-multimeter-insulation-tester/">HT Instruments NEPTUNE Multimeter/Insulation Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The HT Instruments NEPTUNE Multimeter/Insulation Tester is a mix of technology that includes an instrument for electrical safety testing (insulation up to 1000V and continuity with 200mA), an Harmonics analyzer and a True  RMS multimeter.</p>
<h4>HT Instruments NEPTUNE Key Features:</h4>
<ul>
<li>it can quickly measure insulation up to 1000V, just like top-of-the-range testers.</li>
<li>50,100,250,500,1000VDC Insulation test voltages.</li>
<li>it measures continuity of protective conductors with 200mA to solve the most common problems related to masses.</li>
<li>measure Inrush currents, Harmonics and THD%, just like top-of-the-range power quality analyzers.</li>
<li>with a wide range of external clamp transducers it can measure AC TRMS, DC, AC+DC current and Inrush current, starting from 1mA up to 3000A.</li>
<li>compare each measurement with the limits prescribed by the Guidelines and I provide a clear result OK or NOT OK</li>
<li>it&#8217;s a multimeter with functions only available if using top-of-the-range instruments.</li>
<li>CAT IV 600V, CAT III 1000V Safety Rating</li>
<li>Similar to the Fluke 1587 &amp; Fluke 1577</li>
<li>ISO 9000 CALIBRATION CERTIFICATE INCLUDED</li>
</ul>
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellcategory" colspan="2">
<h4><strong>HT Instruments NEPTUNE Technical Specifications</strong></h4>
</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>DC voltage</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.0V ÷ 999.9V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.1V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(0.5%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>AC TRMS, DC, AC+DC TRMS, LoZ voltage</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.5V ÷ 999.9V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.1V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">32Hz ÷ 1kHz</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(0.5%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>AC TRMS current with flexible clamp F3000U</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1A ÷ 3000A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.01A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(0.5%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>AC TRMS, DC, AC+DC TRMS current with standard clamp</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1mV ÷ 1000mV</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1mV</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(0.5%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Inrush current (DIRC) &#8211; Flexible clamp F3000U</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1A ÷ 3000A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.01A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">42.5Hz ÷ 69Hz</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(2.0%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Response time of peak</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1ms</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Max RMS response time</span></td>
<td class="speccelldata"><span style="font-size: 90%;">16.6ms, 20ms, 50ms, 100ms, 150ms, 175ms, 200ms</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Inrush current (DIRC) &#8211; Standard clamp</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1mV ÷ 1000mV</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1mV</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">42.5Hz ÷ 69Hz</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(2.0%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Response time of peak</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1ms</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Max RMS response time</span></td>
<td class="speccelldata"><span style="font-size: 90%;">16.6ms, 20ms, 50ms, 100ms, 150ms, 175ms, 200ms</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Resistance and Continuity test</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.0Ω ÷ 1999Ω</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.1Ω</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(1.0%reading + 5digits)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Buzzer test</span></td>
<td class="speccelldata"><span style="font-size: 90%;">R&lt;30Ω</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Voltage / Current harmonics</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Harmonic order</span></td>
<td class="speccelldata"><span style="font-size: 90%;">DC, 1st ÷ 25th + THD%</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">42.5Hz ÷ 69Hz</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.1V / 0.1A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(5.0%rdg + 10digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Phase sequence with 1 terminal</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">100V ÷ 999.9V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">42.5Hz ÷ 69Hz</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Insulation resistance</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Test voltages</span></td>
<td class="speccelldata"><span style="font-size: 90%;">50,100,250,500,1000VDC</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range (@ 500V)</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.01MΩ ÷ 999MΩ</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.01MΩ ÷ 1MΩ</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic accuracy (@ 500V)</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(2.0%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Timer for measurements</span></td>
<td class="speccelldata"><span style="font-size: 90%;">15s, 30s, 1min, 5min, 10min</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Continuity of protective conductors</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Test current</span></td>
<td class="speccelldata"><span style="font-size: 90%;">&gt;200mA DC (@ R&lt;5Ω)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.00Ω ÷ 199.9Ω</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Open-circuit voltage</span></td>
<td class="speccelldata"><span style="font-size: 90%;">4 &lt; Vo &lt; 12V DC</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(2.0%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>General characteristics</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Instrument safety</span></td>
<td class="speccelldata"><span style="font-size: 90%;">IEC/EN61010-1, IEC/EN61010-2-030, IEC/EN61010-2-033</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">EMC</span></td>
<td class="speccelldata"><span style="font-size: 90%;">IEC/EN 61326-1</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Test MΩ</span></td>
<td class="speccelldata"><span style="font-size: 90%;">CEI 64-8, IEC/EN61557-2</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Test LoΩ</span></td>
<td class="speccelldata"><span style="font-size: 90%;">CEI 64-8, IEC/EN61557-4</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Phase sequence</span></td>
<td class="speccelldata"><span style="font-size: 90%;">IEC/EN 61557-7</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Insulation</span></td>
<td class="speccelldata"><span style="font-size: 90%;">double insulation</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Pollution level</span></td>
<td class="speccelldata"><span style="font-size: 90%;">2</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measurement category</span></td>
<td class="speccelldata"><span style="font-size: 90%;">CAT IV 600V, CAT III 1000V to earth and between inputs</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;">Mechanical characteristics</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Size (L x W x H)</span></td>
<td class="speccelldata"><span style="font-size: 90%;">175 x 85 x 55mm</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Weight (batteries included)</span></td>
<td class="speccelldata"><span style="font-size: 90%;">420g</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Mechanical protection</span></td>
<td class="speccelldata"><span style="font-size: 90%;">IP40</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Power supply</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Battery type</span></td>
<td class="speccelldata"><span style="font-size: 90%;">4&#215;1.5V batteries type AAA IEC LR03</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Auto power off</span></td>
<td class="speccelldata"><span style="font-size: 90%;">after 15 minutes’ idling</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;">Display</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Type of display</span></td>
<td class="speccelldata"><span style="font-size: 90%;">4 dgt LCD, max 9999 dots, decimal sign, point, backlight and bargraph, indication of polarity</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Updating frequency</span></td>
<td class="speccelldata"><span style="font-size: 90%;">2 times/s</span></td>
</tr>
</tbody>
</table>
<h3>HT Instruments NEPTUNE  Included Accessories:</h3>
<p>• 4324-2 Pair of Red/Black banana connectors with 2/4mm tip<br />
• YAAMK0001HT0 Pair of Red/Black alligator clips<br />
• YABAT0001HT0 Alkaline battery type AAA IEC LR03 1.5V, 4 pieces<br />
• YABRS0002HT0 Carrying bag<br />
• YAMUM0068HT0 User manual on CD-ROM<br />
• YAMUM0067HT0 Quick user guide<br />
• Calibration certificate ISO9000</p>
<h3>Optional Accessories:</h3>
<p>• F3000U Flexible clamp with full scale 30/300/3000A AC and banana connectors<br />
• HT96U* Standard clamp with full scale 1/100/1000A AC and Hypertac connector<br />
• HT97U* Standard clamp with full scale 10/100/1000A AC and Hypertac connector<br />
• HT98U* Standard clamp with full scale 1000A DC and Hypertac connector<br />
• HT4006 Standard clamp with full scale 40/400A AC/DC and banana connectors<br />
• NOCANBA Adapter for clamp connection with Hypertac connector<br />
• 5004-IECR Red alligator clip<br />
• 5004-IECN Black alligator clip<br />
• C2065 3-wire cable Red, Black and Green with Schuko plug</p>
<p>The post <a href="https://rapid-tech.com.au/ht-instruments-neptune-multimeter-insulation-tester/">HT Instruments NEPTUNE Multimeter/Insulation Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HT INSTRUMENTS GSC60 Multifunction Electrical Analyzer</title>
		<link>https://rapid-tech.com.au/ht-instruments-gsc60-professional-electrical-analyzer/</link>
					<comments>https://rapid-tech.com.au/ht-instruments-gsc60-professional-electrical-analyzer/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 12 Jul 2016 07:12:41 +0000</pubDate>
				<guid isPermaLink="false">http://rapid-tech.com.au/?post_type=product&#038;p=4095</guid>

					<description><![CDATA[<p><a href="http://rapid-tech.com.au/wp-content/uploads/2017/08/HT-Italia-Aus-small.jpg"><img class="alignnone size-full wp-image-5619" src="http://rapid-tech.com.au/wp-content/uploads/2017/08/HT-Italia-Aus-small.jpg" alt="HT-Italia-Aus-small" width="192" height="100" /></a></p>
<h4><strong>The GSC60 is a Multifunction Electrical Analyzer. </strong></h4>
<p><em><strong><span class="h-large drop-shadow text-bordered-primary" style="color: #ed1c24;">"No other instrument can match it's versatility."</span></strong></em></p>
<h4><span style="color: #ff0000;"><strong>NOTE:</strong></span> This is the Australian version with the correct wiring colours and RCM / C Tick certification and Hard ABS Wheeled Case.</h4>
<p><img class="alignnone wp-image-4418" src="http://rapid-tech.com.au/wp-content/uploads/2016/07/RCM.jpg" alt="rcm" width="75" height="55" /></p>
<h5><strong>The GSC60 Measures:</strong></h5>
<ul>
<li><strong>Power Quality</strong> - 9 types of Electrical Systems (both single &#38; 3 phase)</li>
<li><strong>Installation Testing</strong></li>
<li><strong>Earth Resistance</strong> - 2 or 3 Pole</li>
<li><strong>Soil Resistivity</strong> - 4 pole Wenner method</li>
<li><strong>RCD Testing</strong> - A, AC &#38; B</li>
<li><strong>Insulation Resistance</strong> - up to 1000V</li>
<li><strong>Continuity</strong> - test currents up to 200mA</li>
<li><strong>Advanced Loop Testing</strong></li>
<li><strong>Phase Sequence</strong></li>
<li><strong>Leakage Current</strong></li>
<li>
<h5><span style="color: #ff0000;"><strong>Cat IV Safety Rating</strong></span></h5>
</li>
</ul>
<p>&#160;</p>
<h4><strong><span style="text-decoration: underline;"><span style="color: #800080; text-decoration: underline;">Ask about our Trade-In deal of your old or unused instruments!</span></span></strong></h4>
<p>&#160;</p>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline; color: #0000ff;"><strong><a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2016/07/GSC60-Brochure.pdf" rel="noopener">GSC60 Brochure</a></strong></span></h5>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline; color: #0000ff;"><strong><a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2016/07/GSC60-Rapid-Tech.pdf" rel="noopener">GSC60 Datasheet</a></strong></span></h5>
<p>The post <a href="https://rapid-tech.com.au/ht-instruments-gsc60-professional-electrical-analyzer/">HT INSTRUMENTS GSC60 Multifunction Electrical Analyzer</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2><strong>The HT INSTRUMENTS GSC60 &#8211; One instrument for all electrical safety tests.</strong></h2>
<p>&nbsp;</p>
<p><iframe loading="lazy" title="Multifunction tester with Power quality analyzer GSC60 HT instruments" width="1020" height="574" src="https://www.youtube.com/embed/7LqND-OF0jc?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" allowfullscreen></iframe></p>
<h2><strong><span style="color: #f99b1c;">The GSC60 MEASURES:</span></strong></h2>
<p><strong>›    </strong><strong>Earth</strong> <strong>Resistance</strong> with 2- or 3-pole <strong>volt-ampere method </strong>in TT, TN and IT systems, <strong>non-trip earth loop impedance measurement</strong>, <strong>stackless earth ground resistance measurement  </strong>with T2100 (optional).</p>
<p><strong>›    </strong><strong>Soil</strong> <strong>Resistivity</strong> with <strong>4 pole </strong>Wenner method.</p>
<p><strong>›    </strong><strong>RCD</strong> <strong>Testing</strong> <strong>type</strong> A, AC, B with test current up to 10A.**</p>
<p><strong>›    </strong><strong>Insulation</strong> <strong>Resistance</strong> measurement with test voltage <strong>up</strong> <strong>to</strong> <strong>1000V</strong>.</p>
<p><strong>›    </strong><strong>Continuity </strong>measurement of protective conductors with test current <strong>up to 200mA</strong>.</p>
<p><strong>›    </strong><strong>Advanced </strong><strong>Loop </strong>Testing of MCBs, fuses and cable sizing.</p>
<p><strong>›    </strong>Measurement of <strong>phase sequence (SEQ)</strong>.</p>
<p>›    Measurement and recording of environment parameters and leakage currents through external probes.</p>
<h2><span style="color: #f99b1c;"><strong>HT INSTRUMENTS GSC60 for the Analysis of Power Quality and Energy Consumption.</strong></span></h2>
<p><strong>›    </strong><strong>9 types of electrical systems: </strong>1Φ-2wires, 1Φ-split phase, 3Φ-3 wires, 3Φ-Aron, 3Φ-Open Δ, 3Φ-Open Y, 3Φ-2 el. 1/2, 3Φ-4 wires Y, 3Φ-High Leg.</p>
<p><strong>›    </strong><strong>632</strong> <strong>parameters</strong> <strong>can</strong> <strong>be</strong> <strong>recorded</strong> <strong>for</strong> <strong>over</strong> <strong>two</strong> <strong>months</strong>.</p>
<p><strong>›    </strong><strong>Real</strong> <strong>Time</strong>. Real-time display of all <strong>waveforms</strong>, <strong>harmonics</strong>, <strong>vector</strong> <strong>diagrams</strong> as well as <strong>summary</strong> <strong>function </strong>on phases for a <strong>quick reading </strong>of the most important parameters.</p>
<p><strong>›    </strong><strong>Voltage</strong> <strong>Anomalies</strong>. Detection of voltage anomalies with a resolution of <strong>20ms</strong>.</p>
<p><strong>›    </strong><strong>Energy</strong> <strong>Saving.</strong> <strong>One</strong> <strong>click</strong> <strong>allows</strong> <strong>you</strong> <strong>to</strong> <strong>check</strong> <strong>all</strong> <strong>the</strong> <strong>electrical</strong> <strong>absorption</strong> of all the equipment connected to the main power supply and save on energy costs.</p>
<h2><span style="color: #f99b1c;">Live. Real Time Analysis.</span></h2>
<p>Wi-Fi connection allows you to display wave forms, vector diagrams, harmonics and all electrical parameters for each phase on your tablet/smartphone/PC</p>
<p>GSC60 helps to dispel the myth that recording analysis is complex. App HTanalysis makes it simple and clear. Using ZOOM Functions you can display all the recorded quantities. JUMP Function displays harmonics in any recording step just by clicking on the quantity.</p>
<h2><span style="color: #f99b1c;"><strong>HT INSTRUMENTS GSC60 Functions:</strong></span></h2>
<div class="mm-page mm-slideout">
<div class="container-body center-block">
<div class="pg-opt prodotti">
<div class="container-fluid">
<div class="row">
<div class="col-md-12">
<section class="slice bg-greyprod">
<div class="container">
<div class="tab-content">
<div id="tab-2" class="tab-pane fade active in">
<div class="tab-body prodotti">
<div class="list-check">
<table border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr class="list-item">
<td class="function thin-font"><span style="color: #000000;">Touchscreen colour display</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Integrated WiFi connection and compatibility with HTANALYSIS App</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Continuity of protective circuit with 200mA</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Insulation with voltage 50, 100, 250, 500, 1000VDC</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Time/Current tripping of A, AC General, Selective and Delayed RCDs up to 1000mA</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Time/Current tripping of type B RCDs up to 300mA</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Tripping time and current of RCDs with separate clamp jaws type B, A, AC Standard, Selective and Delayed up to 10A</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Loop impedance P-N, P-P, P-PE and calculation of prospective short-circuit current</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Line/Loop impedance with high resolution (with optional accessory IMP57)</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Percentage voltage drop on the line</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Measurement and recording of leakage currents and environment parameters</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><strong> Three-phase Power quality and Energy consumption analysis:</strong><br />
♦  <span style="color: #000000;"> 9 types of electrical systems:</span><br />
<span style="color: #000000;"> ♦   1Φ-2wires, 1Φ-split phase, 3Φ-3 wires, 3Φ-Aron, 3Φ-Open Δ, 3Φ-Open Y, 3Φ-2 el. 1/2, 3Φ-4 wires Y, 3Φ-High Leg.</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     632 parameters can be recorded for over two months</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Voltage Anomalies (dips and peaks) with a resolution of 20ms @ 50Hz</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Measurement/recording of Active, Reactive, Apparent Power</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Measurement/recording of Active, Reactive, Apparent Energy</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Measurement/recording of Cosphi, Power Factor</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Measurement/Recording of Voltage and Current Harmonics up to 49th with THD%</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Voltage/current vector diagram</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Voltage/current waveforms</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Tables or histograms of Harmonics and THD%</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function">     Summary table of main electric parameters</td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function">     Help on line on the display</td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function">     Protection category &#8211; CAT IV</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
<h3><strong><span style="color: #f99b1c;">Standard Accessories:</span></strong></h3>
<p>• HTFLEX33E AC flexible clamp for currents up to 3000A, diameter 174mm, 4 pieces<br />
• C2033X 3-banana to Shuko plug cable<br />
• UNIVERSALKITG3 Set of 4 cables, 4 alligator clips and 3 test leads<br />
• KITTERRNE Soft carrying bag containing 4 cables and 4 earth rods<br />
• PR400 Remote switch probe<br />
• PT400 Stylus<br />
• PELICAN style hard ABS case with wheels and telescopic handle<br />
• TOPVIEW2006 PC software and optical-to-USB connection cable C2006<br />
• YABAT0003000 Rechargeable NiMH battery 1.2V, AA, 6 pcs<br />
• A0060 Power Supplier\Battery Charger 100/230Vac &#8211; 15Vdc, 10W CAT IV<br />
• C7051 Power cable Shuko-Europlug ground-less 1.50mt<br />
• SP-5100 Hands Free kit<br />
• Quick user’s guide<br />
• User’s manual on CD-ROM<br />
• Calibration certificate ISO9000</p>
</div>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-4428" src="http://rapid-tech.com.au/wp-content/uploads/2016/07/GSC60-Accessories-Case.jpg" alt="gsc60-accessories-case" width="601" height="432" srcset="https://rapid-tech.com.au/wp-content/uploads/2016/07/GSC60-Accessories-Case.jpg 836w, https://rapid-tech.com.au/wp-content/uploads/2016/07/GSC60-Accessories-Case-300x215.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2016/07/GSC60-Accessories-Case-600x431.jpg 600w, https://rapid-tech.com.au/wp-content/uploads/2016/07/GSC60-Accessories-Case-768x551.jpg 768w" sizes="auto, (max-width: 601px) 100vw, 601px" /></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
</section>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://rapid-tech.com.au/ht-instruments-gsc60-professional-electrical-analyzer/">HT INSTRUMENTS GSC60 Multifunction Electrical Analyzer</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/ht-instruments-gsc60-professional-electrical-analyzer/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT Italia HT9 Two-pole CAT IV  Voltage Tester with Lamp Test</title>
		<link>https://rapid-tech.com.au/ht-italia-ht9-pen-type-digital-multimeter-lamp-test/</link>
					<comments>https://rapid-tech.com.au/ht-italia-ht9-pen-type-digital-multimeter-lamp-test/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Mon, 09 May 2016 10:02:30 +0000</pubDate>
				<guid isPermaLink="false">http://rapid-tech.com.au/?post_type=product&#038;p=3342</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-974" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/HT-ITALIA-LOGO-1.png" alt="HT ITALIA LOGO" width="160" height="100" /></p>
<p>&#160;</p>
<p><a target="_blank" href="https://mymeter.com.au/product/kyoritsu-1030-digital-pen-multimeter/" rel="noopener"><img class="alignnone size-full wp-image-17843" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/BUY-NOW-form-My-Meter-e1620004827208.png" alt="Buy now form My Meter" width="220" height="55" /></a></p>
<div class="productDetails">
<div class="itemDesc">
<p id="pShortDesc"><strong>HT Italia HT9 Two pole voltage tester with Lamp test</strong></p>
</div>
</div>
<p class="block">In addition to DC/AC voltage measurement and continuity testing the HT Italia HT9 also offers gas-filled lamp tests and phase sequence/conformity detection features.</p>
<h4>HT Italia HT9 Features:</h4>
<ul>
<li>DC/AC voltage up to 690V</li>
<li>AC voltage detector with 1 wire method</li>
<li>Neon and fluorescent lamp test</li>
<li>Sodium/mercury vapor lamp test</li>
<li>Halogen lamp test</li>
<li>Non-electronic ballast test</li>
<li>Continuity test</li>
<li>Phase sequence test</li>
<li>Diode test</li>
<li>LED and acoustic indications</li>
<li>Built-in torch</li>
<li>LCD display</li>
<li>Safety: IEC/EN61010-1, IEC/EN61010-2-030, IEC/EN61243-3:2010</li>
<li>Measurement category: CAT III 690V, CAT IV 600V</li>
</ul>
<p>&#160;</p>
<p><img class="alignnone size-full wp-image-3188" src="http://rapid-tech.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" />   <a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2016/05/HT-9-8-6.pdf" rel="noopener">HT9-8-6 Brochure</a></p>
<p><img class="alignnone size-full wp-image-3188" src="http://rapid-tech.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" />    <a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2016/05/HT9-8-6-User-Manual.pdf" rel="noopener">HT9-8-6 User Manual</a></p>
<p>The post <a href="https://rapid-tech.com.au/ht-italia-ht9-pen-type-digital-multimeter-lamp-test/">HT Italia HT9 Two-pole CAT IV  Voltage Tester with Lamp Test</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>To overcome difficult pinpointing of the right cable within a frame on a switchboard under poor light conditions, a built-in white LED flashlight makes testing possible and easy even in dark environments. The slim and ergonomic design of HT Italia HT9 is highly appreciated by contracting electricians, field professionals, troubleshooters as well as any kind of user.</p>
<p>Designed according to the requirements of field professionals, HT Italia HT9 is must-have troubleshooting tool.</p>
<p><b>Two pole voltage meter with Lamp Test. With built-in gas-filled lamp tester and non-contact phase sequence/conformity tester</b></p>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-3344" src="http://rapid-tech.com.au/wp-content/uploads/2016/05/HT9_small3.jpg" alt="HT9_small3" width="273" height="220" /></p>
<p>Digital two pole voltage tester HT Italia HT9 provides daily use features. In addition to DC/AC voltage measurement and continuity test, HT9 also offers gas-filled lamp test and phase sequence/conformity detection features. To overcome difficult pinpointing of the right cable within a frame on a switchboard under poor light conditions, a built-in white LED flashlight makes testing possible and easy even in dark environments. The slim and ergonomic design of HT9 is highly appreciated by contracting electricians, field professionals, troubleshooters as well as any vkind of user. Designed according to the requirements of field professionals, HT9 is must-have troubleshooting tool.</p>
<table class="spectable" style="height: 226px;" border="0" width="560" cellspacing="0" cellpadding="0" align="center">
<tbody>
<tr>
<td class="speccellcategory" colspan="3" align="center"><strong>Figure 2 &#8211; HT Italia HT9 LED and Display Description</strong></td>
</tr>
<tr>
<td class="speccelltitle" align="center" width="50"><strong>1.</strong></td>
<td class="speccelldata">Voltage indication leds</td>
<td class="speccelldata" rowspan="9" align="center"> <img loading="lazy" decoding="async" class="alignnone size-full wp-image-3343" src="http://rapid-tech.com.au/wp-content/uploads/2016/05/HT9-LED-Display.jpg" alt="HT9 LED Display" width="238" height="290" /></td>
</tr>
<tr>
<td class="speccelltitle" align="center" width="50"><strong>2.</strong></td>
<td class="speccelldata">Buzzer hole for acoustic signal</td>
</tr>
<tr>
<td class="speccelltitle" align="center" width="50"><strong>3.</strong></td>
<td class="speccelldata">Indication led Lamp test</td>
</tr>
<tr>
<td class="speccelltitle" align="center" width="50"><strong>4.</strong></td>
<td class="speccelldata">Indication led Phase sequence</td>
</tr>
<tr>
<td class="speccelltitle" align="center" width="50"><strong>5.</strong></td>
<td class="speccelldata">Indication led Phase detection / Dangerous voltage</td>
</tr>
<tr>
<td class="speccelltitle" align="center" width="50"><strong>6.</strong></td>
<td class="speccelldata">Indication led Continuity test</td>
</tr>
<tr>
<td class="speccelltitle" align="center" width="50"><strong>7.</strong></td>
<td class="speccelldata">Indication led 12V and positive or negative polarity</td>
</tr>
<tr>
<td class="speccelltitle" align="center" width="50"><strong>8.</strong></td>
<td class="speccelldata">LCD display with voltage, polarity and flat battery indic</td>
</tr>
</tbody>
</table>
<table border="0" width="95%" cellspacing="5" cellpadding="5" align="center">
<tbody>
<tr>
<td valign="top">The HT Italia HT9 can also be used to check reactors, starters,<br />
capacitors and resistors, further to the following kinds of lamps:</p>
<ul>
<li>Fluorescent lamps</li>
<li>Low-pressure sodium lamps</li>
<li>High-pressure sodium lamps</li>
<li>Neon tubes</li>
<li>Mercury-vapour lamps and halogen lamps</li>
</ul>
</td>
<td valign="top"><b>Standards</b></p>
<ul>
<li>EMC 2004/108/CE Directive</li>
<li>CE MARK</li>
<li>IEC/EN 61010-1</li>
<li>IEC/EN61010-2-030</li>
<li>IEC/EN61243-3:2010</li>
<li>LVD 2006/95/CE Directive</li>
</ul>
</td>
</tr>
</tbody>
</table>
<h3>HT Italia HT9 Specifications:</h3>
<div id="tab-specifications" class="tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom ui-tabs-hide">
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellheader" colspan="2">TECHNICAL SPECIFICATIONS</td>
</tr>
<tr>
<td class="speccelldata" colspan="2"><small>Accuracy indicated as: ±[%rdg + (num. dgt * resolution)] at 23°C ± 5°C, &lt;70%HR</small></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">AC/DC VOLTAGE MEASUREMENT</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Range [V]</td>
<td class="speccelldata">12.0 &#8211; 299.9<br />
300 &#8211; 690</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Resolution [V]</td>
<td class="speccelldata">0.1<br />
1</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Frequency range [Hz]</td>
<td class="speccelldata">16 &#8211; 400</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Accuracy</td>
<td class="speccelldata">+/-(3%rdg + 5dgt)</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Overload protection</td>
<td class="speccelldata">690VDC/AC</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">AC VOLTAGE WITH 1 WIRE</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Range [V]</td>
<td class="speccelldata">100 &#8211; 690</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Frequency range [Hz]</td>
<td class="speccelldata">50 &#8211; 60</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Measurement method</td>
<td class="speccelldata">1-wire with contact on metal live parts</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Overload protection</td>
<td class="speccelldata">690VAC</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">PHASE SEQUENCE INDICATION</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Voltage range [V]</td>
<td class="speccelldata">120 &#8211; 400 (Phase – Earth)</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Frequency range [Hz]</td>
<td class="speccelldata">50 &#8211; 60</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Measurement method</td>
<td class="speccelldata">2-wires with contact on metal live parts</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">LAMP TEST</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Voltage with new battery</td>
<td class="speccelldata">Approx 3kV / 240kHz</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Field intensity (200-280kHz)</td>
<td class="speccelldata">Approx 100µV/m</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Indications</td>
<td class="speccelldata">LED blinking</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">CONTINUITY TEST</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Range</td>
<td class="speccelldata">0 &#8211; 500KΩ + 50%</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Test current</td>
<td class="speccelldata">&lt;7µA</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Indications</td>
<td class="speccelldata">LED + acoustic signal</td>
</tr>
<tr>
<td class="speccellheader" colspan="2">GENERAL SPECIFICATIONS</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Mechanical specifications</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Dimensions (L x W x H)</td>
<td class="speccelldata">255 x 60 x 35mm</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Weight (included batteries)</td>
<td class="speccelldata">170g</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Encapsulation</td>
<td class="speccelldata">IP64</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Display</td>
<td class="speccelldata">LED, LCD</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Power supply</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Internal supply</td>
<td class="speccelldata">2&#215;1.5V alkaline batteries type AAA, IEC LR03</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Reference guidelines</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Safety</td>
<td class="speccelldata">IEC/EN61010-1, IEC/EN61010-2-030, IEC/EN61243-3:2010</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Insulation</td>
<td class="speccelldata">double insulation</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Pollution degree</td>
<td class="speccelldata">2</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Measurement category</td>
<td class="speccelldata">CAT III 690V; CAT IV 600V</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Max height of use</td>
<td class="speccelldata">2000m</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Environmental conditions</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Reference temperature</td>
<td class="speccelldata">23°C ± 5°C</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Working temperature</td>
<td class="speccelldata">-15 to 55°C</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Working humidity</td>
<td class="speccelldata">&lt;85%HR</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Storage temperature</td>
<td class="speccelldata">-20 to 70°C</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Storage humidity</td>
<td class="speccelldata">&lt;85%HR</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
</div>
<p>The post <a href="https://rapid-tech.com.au/ht-italia-ht9-pen-type-digital-multimeter-lamp-test/">HT Italia HT9 Two-pole CAT IV  Voltage Tester with Lamp Test</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/ht-italia-ht9-pen-type-digital-multimeter-lamp-test/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT Italia HT70 Voltage Stick with Phase Sequence Tester</title>
		<link>https://rapid-tech.com.au/ht-italia-ht70-voltage-stick-phase-sequence-tester/</link>
					<comments>https://rapid-tech.com.au/ht-italia-ht70-voltage-stick-phase-sequence-tester/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Thu, 17 Mar 2016 03:13:30 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=1740</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-1537" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/HT_Italia_Ca.jpg" alt="HT_Italia_Ca" width="73" height="89" /></p>
<p><span style="color: #000000;"><strong>HT Italia HT70 is a practical innovative pen device capable of carrying out, further to the phase detection function, a phase sequence and phase concordance test with LED indications and buzzer, also on the insulating sheath of the conductors.</strong></span></p>
<p>The result of the test is indicated by the<br />
<span style="color: #ff0000;"><strong>R</strong><strong><span style="color: #ff0000;">e</span>d LED</strong> </span><strong>(incorrect phase sequence)</strong> or the<br />
<strong><span style="color: #339966;">Green LED</span> (correct phase sequence) </strong>turning on, by simply moving the sensor first on the L1 and then on the L2 phase.</p>
<h5><strong>HT Italia HT70 Features:</strong></h5>
<ul>
<li>AC voltage range detection: 100 - 1000V AC to ground</li>
<li>Frequency range: 50/60Hz</li>
<li>Phase sequence indication with 1-wire</li>
<li>Conformity test with 1-wire</li>
<li>Safety: IEC/EN61010-1</li>
<li>Category of measurement: CAT IV-1000V</li>
<li>Insulation: double insulation</li>
<li>Pollution degree: 2</li>
<li><strong><span style="color: #ff0000;">Red LED</span></strong> indication =&#62; incorrect phase sequence indication</li>
<li><strong><span style="color: #339966;">Green LED</span></strong> indication =&#62; correct phase sequence indication</li>
<li>Buzzer indication</li>
<li>Power supply: 2x1.5V batteries alkaline type AAA</li>
<li>Working temperature: -10°C  50°C</li>
<li>Working humidity: &#60;75%RH(-10°C to 40°C), &#60;45%RH (40°C to 50°C)</li>
<li>Dimensions (LxWxH): 160 x 26 x 20mm</li>
<li>Weight (included batteries): 48g</li>
</ul>
<p><img class="alignnone size-full wp-image-1739" src="http://rapid-tech.com.au/wp-content/uploads/2016/03/Warranty-4.jpg" alt="Warranty 4" width="149" height="41" /></p>
<h5><img class="alignnone size-full wp-image-3188" src="http://rapid-tech.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" />    <span style="text-decoration: underline;"><strong><span style="color: #0000ff;"><a style="color: #0000ff; text-decoration: underline;" href="http://rapid-tech.com.au/wp-content/uploads/2016/03/HT70-Data-Sheet.pdf" target="_blank">HT70 Data Sheet</a></span></strong></span></h5>
<h5><img class="alignnone size-full wp-image-3188" src="http://rapid-tech.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" />    <span style="text-decoration: underline;"><strong><span style="color: #0000ff;"><a style="color: #0000ff; text-decoration: underline;" href="http://rapid-tech.com.au/wp-content/uploads/2016/03/HT70-User-Manual.pdf" target="_blank">HT70 User Manual</a></span></strong></span></h5>
<p><a href="https://www.youtube.com/watch?v=h_WqLCLcjcE" target="_blank"><img class="alignnone wp-image-1742" src="http://rapid-tech.com.au/wp-content/uploads/2016/03/ht-70.jpg" alt="ht-70" width="117" height="66" /> <img class="alignnone wp-image-1648" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/Play.jpg" alt="Play" width="53" height="39" /></a></p>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/ht-italia-ht70-voltage-stick-phase-sequence-tester/">HT Italia HT70 Voltage Stick with Phase Sequence Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The HT Italia HT70 pen voltage detector permits both to quickly verify the presence of AC voltage on any type of electrical installation (sockets, cables, fuses, switchboards, etc.) with and without direct contact and also to perform phase sequence indication and conformity test on generic three phase plants by using red and green fixed and blinking LED indications. HT Italia HT70 is designed according to IEC/EN61010-1 safety standard in CAT IV 1000V.</p>
<p>&nbsp;</p>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-3624" src="http://rapid-tech.com.au/wp-content/uploads/2016/03/HT70-1.jpg" alt="HT70-1" width="561" height="301" srcset="https://rapid-tech.com.au/wp-content/uploads/2016/03/HT70-1.jpg 561w, https://rapid-tech.com.au/wp-content/uploads/2016/03/HT70-1-300x161.jpg 300w" sizes="auto, (max-width: 561px) 100vw, 561px" /></p>
<h5><strong>HT ITALIA HT70 Description:</strong></h5>
<ol>
<li>Voltage Detection Sensor</li>
<li>Reference Mark CAT-IV Measurement</li>
<li>Hand Safety Protection</li>
<li>“ON” Switch and white LED indication</li>
<li>Pocket “Pen” Clip</li>
<li>RED/GREEN Indicator</li>
<li>Pressure Point to remove Battery Cover</li>
<li>Battery Cover Slide.</li>
</ol>
<h5><strong>Voltage detection test:</strong></h5>
<p>1. Turn on the meter by pressing ON/OFF key for at least 1s. Waiting for the standby mode when the green LED is blinking</p>
<p>2. Position the sensor close to or in contact with the point under test for a time &lt;5s, then verify that the red LED is on and buzzer sounds continuously as evidence of voltage detection. Do not perform test with the operator’s hand beyond the hand safety protection and position not insulated wires beyond the CAT IV reference mark (see part 2 of the picture above)</p>
<p>3. Press ON/OFF key for at least 3s to turn off the meter</p>
<h3>HT Italia HT70 Specifications:</h3>
<div id="tab-specifications" class="tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom ui-tabs-hide">
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellcategory" colspan="2">ELECTRICAL SPECIFICATIONS</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">AC voltage range detection</td>
<td class="speccelldata">100 &#8211; 1000V AC to ground</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Frequency range</td>
<td class="speccelldata">50/60Hz</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Safety</td>
<td class="speccelldata">IEC/EN61010-1</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Category of measurement</td>
<td class="speccelldata">CAT IV 1000V</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Insulation</td>
<td class="speccelldata">double insulation</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Pollution degree</td>
<td class="speccelldata">2</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">GENERAL SPECIFICATIONS</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Power supply</td>
<td class="speccelldata">2&#215;1.5V batteries alkaline type AAA NEDA24A LR03</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Working temperature</td>
<td class="speccelldata">-10°C to 50°C</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Working humidity</td>
<td class="speccelldata">&lt;75%HR (-10°C to 40°C)<br />
&lt;45%HR (40°C to 50°C)</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Dimensions (L x W x H)</td>
<td class="speccelldata">160x26x20mm</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Weight (included batteries)</td>
<td class="speccelldata">48g</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://rapid-tech.com.au/ht-italia-ht70-voltage-stick-phase-sequence-tester/">HT Italia HT70 Voltage Stick with Phase Sequence Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/ht-italia-ht70-voltage-stick-phase-sequence-tester/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT ITALIA HT20S Phase Detector with Torch</title>
		<link>https://rapid-tech.com.au/ht-italia-ht20-phase-detector-integrated-torch/</link>
					<comments>https://rapid-tech.com.au/ht-italia-ht20-phase-detector-integrated-torch/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Thu, 17 Mar 2016 02:28:42 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=1732</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-1537" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/HT_Italia_Ca.jpg" alt="HT_Italia_Ca" width="73" height="89" /></p>
<h5>Pen phase detector HT ITALIA HT20S allows <strong>very quickly checking</strong> for the <strong>presence of AC voltage on any kind of electric installation with and without direct contact</strong>.</h5>
<p>A <span style="color: #ff0000;"><strong>Red LED</strong></span> turns on and a <strong>buzzer sounding reveal the presence of voltage</strong>.</p>
<h5><strong>Features:</strong></h5>
<ul>
<li>AC voltage range detection: 100 - 1000V AC to ground</li>
<li>Frequency range: 50/60H</li>
<li>Safety: IEC/EN61010-1</li>
<li>Category of measurement: <strong>CAT IV-1000V</strong></li>
<li>Insulation: double insulation</li>
<li>Pollution degree: 2</li>
<li>Red LED indication of detected voltage</li>
<li>Buzzer indication</li>
<li>White LED torch with ON/OFF key</li>
<li>Power supply: 2x1.5V batteries alkaline type AAA</li>
<li>Working temperature: -10°C to 50°C</li>
<li>Working humidity: &#60;75%RH (-10°C to 40°C),&#60;45%RH (40°C to 50°C)</li>
<li>Size (L-W-H): 160 x 26 x 20mm</li>
<li>Weight (included batteries): 48g</li>
</ul>
<p><img class="alignnone size-full wp-image-1739" src="http://rapid-tech.com.au/wp-content/uploads/2016/03/Warranty-4.jpg" alt="Warranty 4" width="149" height="41" /></p>
<h5><img class="alignnone size-full wp-image-3188" src="http://rapid-tech.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" />   <strong><span style="color: #0000ff;"> <span style="text-decoration: underline;"><a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2016/03/HT20S-manual.pdf" rel="noopener">HT20S User Manual</a></span></span></strong></h5>
<p style="text-align: center;">
<p>The post <a href="https://rapid-tech.com.au/ht-italia-ht20-phase-detector-integrated-torch/">HT ITALIA HT20S Phase Detector with Torch</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>HT ITALIA HT20S meter can perform AC voltage detection with visible LED red and acoustic buzzer indications. A white LED is can be also activated.</p>
<h5><img loading="lazy" decoding="async" class="alignnone size-full wp-image-3622" src="http://rapid-tech.com.au/wp-content/uploads/2016/03/HT20s-1.jpg" alt="HT20s-1" width="341" height="215" srcset="https://rapid-tech.com.au/wp-content/uploads/2016/03/HT20s-1.jpg 341w, https://rapid-tech.com.au/wp-content/uploads/2016/03/HT20s-1-300x189.jpg 300w" sizes="auto, (max-width: 341px) 100vw, 341px" /></h5>
<h5><strong>HT ITALIA HT20S Description:</strong></h5>
<ol>
<li>Voltage Detection Sensor</li>
<li>Reference Mark CAT-IV Measurement</li>
<li>Hand Safety Protection</li>
<li>&#8220;ON&#8221; Switch and white LED indication</li>
<li>Pocket &#8220;Pen&#8221; Clip</li>
<li>White LED Torch</li>
<li>Pressure Point to remove Battery Cover</li>
<li>Battery Cover Slide.</li>
</ol>
<h5>HT ITALIA HT20S Operating Instructions:</h5>
<p>1. Switch on the instrument by pressing key<br />
2. Perform an initial test with meter on an energized circuit. Replace internal batteries if the red LED do not turn on and/or the buzzer do not sound<br />
3. Position the sensor close to or in contact with the point under test then verify that the red LED is on and buzzer sounds continuously as evidence of voltage detection. <strong>Do not perform test with the hand beyond the hand safety protection and do not allow insulated wires beyond the CAT IV reference mark (see part 2 of above picture)</strong><br />
4. If needed press key to turn on the white torch<br />
5. The instrument switch off automatically after 5 minutes of idleness</p>
<h5>HT ITALIA HT20S Technical specifications:</h5>
<ul>
<li>Voltage reference range: 100-1000V AC to ground</li>
<li>Frequency reference range: 50/60Hz</li>
<li>Meter indications: visible LED and acoustic buzzer</li>
<li>Safety: IEC/EN61010-1</li>
<li>Category of measurement: CAT IV 1000V</li>
<li>Pollution degree: 2</li>
<li>Batteries: 2 x 1.5V alkaline type AAA IEC LR03</li>
<li>Working temperature: -10°C to <span style="line-height: 1.5;">50°C</span></li>
<li><span style="line-height: 1.5;">Working humidity: -10 to 40°C;&lt;75%HR; 40-50°C &lt;45%HR </span></li>
<li><span style="line-height: 1.5;">Dimensions (L-W-H): 160 x 26 x 20mm</span></li>
<li><span style="line-height: 1.5;">Weight (included batteries): 48g</span></li>
</ul>
<p>The post <a href="https://rapid-tech.com.au/ht-italia-ht20-phase-detector-integrated-torch/">HT ITALIA HT20S Phase Detector with Torch</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/ht-italia-ht20-phase-detector-integrated-torch/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
