<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Earth/Ground Testers Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/earthground-testers/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/earthground-testers/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Fri, 05 Jun 2026 00:20:44 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.5</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>Earth/Ground Testers Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/earthground-testers/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>KYORITSU KEW 6041BT Insulation Earth Tester &#124; Bluetooth</title>
		<link>https://rapid-tech.com.au/kyoritsu-kew-6041bt-insulation-earth-tester-bluetooth/</link>
					<comments>https://rapid-tech.com.au/kyoritsu-kew-6041bt-insulation-earth-tester-bluetooth/#respond</comments>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Sun, 31 May 2026 23:14:12 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=1119278</guid>

					<description><![CDATA[<p><img class="alignnone wp-image-770" src="https://mymeter.com.au/wp-content/uploads/2014/10/Kyoritsu.png" alt="" width="246" height="52" /></p>
<p><a target="_blank" href="https://mymeter.com.au/product/kyoritsu-kew-6041bt-insulation-earth-tester-bluetooth/" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<p>The KYORITSU KEW 6041BT is a palm-sized insulation earth tester that puts three essential tests — insulation resistance, 2-pole earth resistance and True RMS voltage — into a single probe-style instrument. No fiddling with test leads, no RCD nuisance trips, and Bluetooth straight to your phone for instant reports. Built for sparkies, solar installers and maintenance crews who need fast, compliant results on site. Ready to test right out of the box.</p>
<p><span style="color: #3366ff;"><strong>Initial Stock only available through Rapid Tech Equipment and the MyMeter Store</strong></span></p>
<h4><img class="alignnone size-full wp-image-6653" src="https://mymeter.com.au/wp-content/uploads/2018/10/PDF-blue.png" alt="PDF download" width="43" height="54" /> <a target="_blank" href="https://www.kew-ltd.co.jp/en/download/dl/1580/" rel="noopener"><span style="font-size: 14.4px;">Product Catalog</span></a>  <img class="alignnone size-full wp-image-6653" src="https://mymeter.com.au/wp-content/uploads/2018/10/PDF-blue.png" alt="PDF download" width="43" height="54" /> <a target="_blank" href="https://www.kew-ltd.co.jp/en/download/dl/278/" rel="noopener"><span style="font-size: 14.4px;">Application Catalog</span></a>  <img class="alignnone size-full wp-image-6653" src="https://mymeter.com.au/wp-content/uploads/2018/10/PDF-blue.png" alt="PDF download" width="43" height="54" /> <a target="_blank" href="https://www.kew-ltd.co.jp/en/download/dl/1579/" rel="noopener"><span style="font-size: 14.4px;">Instruction Manual</span></a></h4>
<dl>
<dd></dd>
</dl>
<dl>
<dd></dd>
</dl>
<dl>
<dd></dd>
</dl>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-kew-6041bt-insulation-earth-tester-bluetooth/">KYORITSU KEW 6041BT Insulation Earth Tester | Bluetooth</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold">The Problem: Too Many Leads, Too Little Time</h2>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Anyone who has spent a day fault-finding around a switchboard knows the routine — swap leads for the insulation tester, swap again for the earth tester, then reach for the multimeter to confirm the circuit&#8217;s dead. Three instruments, a tangle of leads, and a real risk of triggering an RCD trip the moment a small test current sneaks down the earth path. On a busy commercial fit-off or a rooftop solar job, that lost time adds up fast, and a nuisance trip can mean climbing back into the roof space to reset a board.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">For Australian trades working to AS/NZS 3000, insulation resistance and earthing checks aren&#8217;t optional — they&#8217;re the backbone of safe verification. The challenge has always been doing them quickly, accurately and without dragging a kit bag of separate testers up a ladder.</p>
<div class="epyt-video-wrapper"><iframe  id="_ytid_12877"  width="1020" height="574"  data-origwidth="1020" data-origheight="574"  data-relstop="1" src="https://www.youtube.com/embed/vMn6VAlRwDY?enablejsapi=1&#038;autoplay=0&#038;cc_load_policy=0&#038;cc_lang_pref=&#038;iv_load_policy=1&#038;loop=0&#038;rel=0&#038;fs=1&#038;playsinline=1&#038;autohide=2&#038;theme=dark&#038;color=red&#038;controls=1&#038;disablekb=0&#038;" class="__youtube_prefs__  epyt-is-override  no-lazyload" title="KYORITSU INSULATION EARTH TESTER KEW 6041BT | Product Introduction"  allow="fullscreen; accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen data-no-lazy="1" data-skipgform_ajax_framebjll=""></iframe></div>
<h2 class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold">The Solution: Three Tests, One Pocket-Sized Probe</h2>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The KEW 6041BT collapses that whole workflow into one palm-sized tester you can hold like a pen. Press the tip to the conductor, hit TEST, and you&#8217;ve got insulation resistance, earth resistance or voltage at a glance. KYORITSU built it around a simple idea — get the technician released from test-lead hassles — and the result is an instrument that&#8217;s genuinely faster to use on real jobs.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">It measures insulation resistance across four ranges (50, 125, 250 and 500 V), checks earth resistance using a simplified 2-pole method, and reads True RMS voltage up to 440 V AC/DC with automatic AC/DC detection. A built-in illuminance sensor wakes the LED light and backlight in dim plant rooms, and glow-in-the-dark switches help you find the controls when you&#8217;re working in a dark roof cavity. Crucially, the earth function uses a test current of 2 mA or less, so you can take earth readings on live installations without unintentionally tripping the RCD.</p>
<h2 class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold">Key Features and What They Mean on the Job</h2>
<ul class="[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3">
<li class="font-claude-response-body whitespace-normal break-words pl-2"><strong>All-in-one probe design</strong> – Insulation, earth and voltage testing in a single 230 g body you operate one-handed. Less gear in the bag, fewer leads to swap, faster results between points.</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2"><strong>Anti-trip earth testing (≤2 mA)</strong> – The low test current on the earth function avoids unintentional RCD trips, so you keep measuring on live boards without resetting protection devices.</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2"><strong>Live circuit warning</strong> – On both insulation and earth functions, an audible alert plus a red LCD backlight flag dangerous voltage (30 V or higher) and lock out measurement until it&#8217;s safe. A built-in safeguard before you apply test voltage.</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2"><strong>True RMS voltage to 440 V</strong> – Accurate readings on distorted waveforms common around VSDs, inverters and switching loads, with AC/DC auto-detection so there&#8217;s one less setting to get wrong.</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2"><strong>Comparator function with audible pass/fail</strong> – Set a threshold and the tester beeps and lights up when a reading falls outside it, so you can run repetitive checks without squinting at every value.</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2"><strong>Auto-discharge</strong> – Stored charge on the circuit under test is automatically bled off after an insulation test, protecting you and the equipment.</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2"><strong>Bluetooth 5.0 to KEW Smart Advanced</strong> – Save readings straight to your phone or tablet, capture location data, and drop results into the supplied Excel report template — paperwork done before you&#8217;ve packed up.</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2"><strong>App-based customisation</strong> – Disable ranges or functions you don&#8217;t use, change the maximum displayed value, or adjust comparator thresholds to suit your workflow and reduce the chance of accidental high-voltage output.</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2"><strong>Replaceable metal tips</strong> – Standard, long and moulded tips are available, plus an optional L-shaped probe for awkward, high or recessed terminals.</li>
</ul>
<p><img fetchpriority="high" decoding="async" class="alignnone size-large wp-image-1119281" src="https://rapid-tech.com.au/wp-content/uploads/2026/06/imgi_37_6041BT_Illumi_1.webp" alt="" width="379" height="379" srcset="https://rapid-tech.com.au/wp-content/uploads/2026/06/imgi_37_6041BT_Illumi_1.webp 379w, https://rapid-tech.com.au/wp-content/uploads/2026/06/imgi_37_6041BT_Illumi_1-300x300.webp 300w, https://rapid-tech.com.au/wp-content/uploads/2026/06/imgi_37_6041BT_Illumi_1-150x150.webp 150w, https://rapid-tech.com.au/wp-content/uploads/2026/06/imgi_37_6041BT_Illumi_1-100x100.webp 100w" sizes="(max-width: 379px) 100vw, 379px" /> <img decoding="async" class="alignnone size-large wp-image-1119282" src="https://rapid-tech.com.au/wp-content/uploads/2026/06/imgi_34_6041BT_Earth_1.webp" alt="" width="379" height="380" srcset="https://rapid-tech.com.au/wp-content/uploads/2026/06/imgi_34_6041BT_Earth_1.webp 379w, https://rapid-tech.com.au/wp-content/uploads/2026/06/imgi_34_6041BT_Earth_1-300x301.webp 300w, https://rapid-tech.com.au/wp-content/uploads/2026/06/imgi_34_6041BT_Earth_1-150x150.webp 150w, https://rapid-tech.com.au/wp-content/uploads/2026/06/imgi_34_6041BT_Earth_1-100x100.webp 100w" sizes="(max-width: 379px) 100vw, 379px" /></p>
<h2 class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold">Technical Specifications</h2>
<div class="overflow-x-auto w-full px-2 mb-6">
<table class="min-w-full border-collapse text-sm leading-[1.7] whitespace-normal">
<thead class="text-left">
<tr>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">Specification</th>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">KEW 6041BT</th>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">Why It Matters</th>
</tr>
</thead>
<tbody>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Insulation test voltages</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">50 / 125 / 250 / 500 V</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Covers low-voltage control wiring through to standard 500 V DC insulation tests required under AS/NZS 3000</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Insulation range (auto)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">2.000 / 20.00 / 200.0 MΩ</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Reads from healthy circuits down to early signs of insulation breakdown</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Insulation accuracy (first range)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">±2% rdg ±2 dgt</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Tight enough for confident pass/fail decisions on compliance testing</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Earth resistance range</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">200.0 / 2000 Ω (auto-ranging)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Suits 2-pole checks on existing earth systems where stakes can&#8217;t be driven</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Earth resistance accuracy</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">±3% rdg ±5 dgt</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Dependable readings for verifying earth continuity and electrode quality</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Earth test current</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">≤2 mA</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Low enough to avoid nuisance RCD trips on live installations</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Voltage measuring range</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">2.0 to 440.0 V AC / ±2.0 to ±440.0 V DC</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Confirms dead circuits and reads three-phase 400 V systems safely</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Voltage accuracy</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">±1% rdg ±4 dgt AC / ±1% rdg ±8 dgt DC</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">True RMS precision on clean and distorted waveforms</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">AC/DC detection</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Automatic (≥2 V)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">One less manual setting; reduces operator error</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Safety rating</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">CAT IV 150 V / CAT III 300 V, Pollution degree 2</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Rated for distribution-level work, including at the origin of the installation</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Ingress protection</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">IP40</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Guards against dust and small objects in plant rooms and switchrooms</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Applicable standards</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">IEC 61010-1, 61010-2-030, 61010-2-034, IEC 61557-1/2/5/10, IEC 60529, IEC 61326 series, IEC 61010-031</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Designed and tested to the international standards underpinning AS/NZS practice</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Communication</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Bluetooth 5.0</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Wireless transfer to Android and iOS via KEW Smart Advanced</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Operating range</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">-10 to 50 °C, ≤85% RH (no condensation)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Handles Australian site extremes from cool plant rooms to hot rooftops</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Storage range</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">-20 to 60 °C, ≤75% RH (no condensation)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Survives a hot ute tray between jobs</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Power</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">2 × AA (LR6) 1.5 V</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Cheap, universal batteries you can grab anywhere</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Dimensions</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">232 (L) × 51 (W) × 42 (D) mm (incl. tip)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Genuinely palm-sized; fits a top pocket or pouch</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Weight</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Approx. 230 g (with batteries)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Light enough for all-day one-handed use</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Display features</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">True RMS, red backlight warning, illuminance sensor, glow-in-the-dark switches</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Stays readable and safe in dim, awkward work areas</td>
</tr>
</tbody>
</table>
</div>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><em>Specifications are drawn from KYORITSU&#8217;s published product data. If you need a full datasheet or instruction manual before purchasing, get in touch and we&#8217;ll send it through.</em></p>
<h2 class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold">Who It&#8217;s For – Real-World Applications</h2>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Electrical contractors and sparkies:</strong> Run insulation resistance and earth checks during fit-off, fault-finding and periodic verification without lugging separate testers. The probe design and live-circuit lockout make point-to-point testing around a switchboard quick and safe.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Solar PV installers:</strong> Carry one compact instrument up to the roof for quick insulation and voltage confirmation on DC and AC sides, with True RMS handling inverter-related waveform distortion. Bluetooth logging means commissioning notes are captured on the spot.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Industrial and facility maintenance teams:</strong> Keep a 6041BT in the toolbox for fast spot-checks on motors, control panels and machinery. The anti-trip earth function lets you verify earthing on running plant without dropping protection, and the comparator&#8217;s audible pass/fail speeds up repetitive routine inspections.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>HVAC and building services technicians:</strong> Confirm circuits are dead, check insulation on plant wiring, and verify earthing on rooftop and plant-room equipment — all from one pocketable tool with a light built in for dark mechanical spaces.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>TAFE, RTOs and training departments:</strong> A safe, simple, app-connected tester that teaches insulation, earth and voltage testing fundamentals, with reporting features students will meet in the field.</p>
<blockquote>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">What is the KYORITSU KEW 6041BT used for?</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The KYORITSU KEW 6041BT is a palm-sized 3-in-1 tester used to measure insulation resistance (50/125/250/500 V), earth resistance (2-pole method, up to 2000 Ω) and True RMS voltage (up to 440 V AC/DC). Electricians, solar installers and maintenance technicians use it for fast, compliant safety testing on site without carrying three separate instruments.</p>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Does the KEW 6041BT prevent RCD nuisance tripping?</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Yes. On the earth resistance function the KEW 6041BT uses a test current of 2 mA or less, which is low enough to take earth readings on live installations without unintentionally tripping RCDs. This lets technicians measure on energised boards without resetting protection devices.</p>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Can the KEW 6041BT measure earth resistance without driving stakes into the ground?</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Yes. The KEW 6041BT is a simplified earth resistance tester that uses the 2-pole measurement method with existing low-resistance earth systems — such as buried metal water pipes, the common earth of the commercial supply, or a building&#8217;s lightning electrode. It&#8217;s designed for situations where auxiliary earth stakes can&#8217;t be driven, like urban or concrete sites.</p>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Is the KEW 6041BT suitable for AS/NZS 3000 insulation testing?</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The KEW 6041BT provides a 500 V DC insulation test range and reads insulation resistance up to 200 MΩ, supporting the insulation resistance verification carried out under the AS/NZS 3000 Wiring Rules. It is rated CAT IV 150 V / CAT III 300 V and built to the IEC 61557 series that underpins Australian testing practice. Always follow the current edition of AS/NZS 3000 and your verification procedures.</p>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Does the KEW 6041BT connect to a phone?</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Yes. The KEW 6041BT has Bluetooth 5.0 and works with the free KEW Smart Advanced app for Android and iOS. You can view live readings, save measured data in CSV, capture location information, and transfer results into an Excel report template to generate test reports on site.</p>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">How accurate is the KEW 6041BT?</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Insulation resistance accuracy is ±2% rdg ±2 dgt in the first effective range, earth resistance is ±3% rdg ±5 dgt, and voltage is ±1% rdg ±4 dgt on AC (True RMS). These tolerances make it dependable for routine compliance pass/fail decisions.</p>
</blockquote>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-kew-6041bt-insulation-earth-tester-bluetooth/">KYORITSU KEW 6041BT Insulation Earth Tester | Bluetooth</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/kyoritsu-kew-6041bt-insulation-earth-tester-bluetooth/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>KYORITSU 4202 Earth Clamp Tester</title>
		<link>https://rapid-tech.com.au/kyoritsu-4202-earth-clamp-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Wed, 05 Dec 2018 05:57:49 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=9403</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-7630" src="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-Authorised.jpg" alt="" width="250" height="69" /></p>
<p>The Kyoritsu 4202 is a digital clamp-on earth resistance tester for use in multi-earthed systems. The Kyoritsu 4202 measures the earth resistance by simply clamping around the earthed wires.<br />
This 4202 also is equipped with AC current function to measure current up to 30A the same as Kyoritsu's traditional leakage clamp meters.</p>
<p>N.B.A single earthing cannot be measured. (only for multiple-earthing system).</p>
<h4><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" />     <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2018/12/Kyoritsu-4202-Datasheet.pdf" rel="noopener">Kyoritsu 4202 Datasheet</a></span></h4>
<h4><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" />     <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2018/12/Kyoritsu-4202-User-Manual.pdf" rel="noopener">Kyoritsu 4202 User Manual</a></span></h4>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-4202-earth-clamp-tester/">KYORITSU 4202 Earth Clamp Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p class="headLine5">The KYORITSU 4202 Earth Clamp Tester has various useful functions available on Android devices using Bluetooth communication</p>
<p style="padding-left: 30px;">• Real time measurements can be transferred, shown and saved on Android device (up to 100 measurements)<br />
• Saved data includes measurement, GPS location and date &amp; time Easy to check on map &#8220;When&#8221; and &#8220;Where&#8221; the measurement was made<br />
• Comparator function on Android device informs when the measured value is lower/higher than the preset value</p>
<p style="padding-left: 30px;"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-9409 aligncenter" src="https://rapid-tech.com.au/wp-content/uploads/2018/12/KEW-SMART-4202.jpg" alt="" width="711" height="295" srcset="https://rapid-tech.com.au/wp-content/uploads/2018/12/KEW-SMART-4202.jpg 711w, https://rapid-tech.com.au/wp-content/uploads/2018/12/KEW-SMART-4202-300x124.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2018/12/KEW-SMART-4202-600x249.jpg 600w" sizes="auto, (max-width: 711px) 100vw, 711px" /></p>
<p><b>Earth /Ground resistance and Leakage current measurement functions</b><br />
• The earth resistance from 0.05 to 1500 Ω can be measured without the auxiliary earth spikes in multi-earthing systems<br />
• True RMS leakage or phase current readings from 0.1mA to 30.0A provides vital additional information in earthing networks<br />
• Filter function offers increased immunity to electrical noise and a Noise mark appears in excessively high noisy environments</p>
<h3>Measurement principle (Why Earth Resistance can be measured by only Clamping it)</h3>
<p>This instrument can measure the earth resistance to earth in multi-earthed system. Let&#8217;s regard earth resistance under test as Rx, and the other earth resistances as<br />
R1, R2, …Rn.</p>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-9406 aligncenter" src="https://rapid-tech.com.au/wp-content/uploads/2018/12/KYORITSU-4202-1.jpg" alt="" width="448" height="187" srcset="https://rapid-tech.com.au/wp-content/uploads/2018/12/KYORITSU-4202-1.jpg 448w, https://rapid-tech.com.au/wp-content/uploads/2018/12/KYORITSU-4202-1-300x125.jpg 300w" sizes="auto, (max-width: 448px) 100vw, 448px" /></p>
<p>Of these earth resistances, R1, R2, …Rn can be considered that they are connected in parallel and can be regarded as a combined resistance Rs. The Rs can be regarded small enough against Rx since a combined resistance consists of several resistances. Following is an equivalent circuit diagram of this circuit</p>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-9407 aligncenter" src="https://rapid-tech.com.au/wp-content/uploads/2018/12/KYORITSU-4202-2.jpg" alt="" width="451" height="252" srcset="https://rapid-tech.com.au/wp-content/uploads/2018/12/KYORITSU-4202-2.jpg 451w, https://rapid-tech.com.au/wp-content/uploads/2018/12/KYORITSU-4202-2-300x168.jpg 300w" sizes="auto, (max-width: 451px) 100vw, 451px" /></p>
<h3>Kyoritsu 4202 Specifications</h3>
<table class="table table-striped">
<tbody>
<tr>
<td colspan="2"><strong>Earth Resistance Auto Range</strong></td>
</tr>
<tr>
<td>Ranges</td>
<td>20.00Ω<br />
200.00Ω<br />
1500Ω</td>
</tr>
<tr>
<td>Accuracy</td>
<td>0.00 to 20.99Ω: ±1.5% ±0.05Ω<br />
16.0 to 99.9Ω: ±2% ±0.5Ω<br />
100.0 to 209.9Ω: ±3% ±2Ω<br />
160 to 399Ω: ±5% ±5Ω<br />
400 to 599Ω: ±10% ±10Ω</td>
</tr>
<tr>
<td colspan="2"><strong>AC Current Auto Range (50Hz/60Hz)</strong></td>
</tr>
<tr>
<td>Ranges</td>
<td>100.0mA<br />
1000mA<br />
10.00A<br />
30.0A</td>
</tr>
<tr>
<td>Accuracy</td>
<td>0.0 to 104.9mA: ±2% ±0.7mA<br />
80mA to 31.5A: ±2%</td>
</tr>
<tr>
<td colspan="2"><strong>Operating Indication</strong></td>
</tr>
<tr>
<td>Earth Resistance Function</td>
<td>Constant Voltage Injection</td>
</tr>
<tr>
<td>Current Detection</td>
<td>Frequency: Approx. 2400Hz</td>
</tr>
<tr>
<td>Dual Integration</td>
<td>AC current Function: Successive Approximation</td>
</tr>
<tr>
<td colspan="2"><strong>General Specifications</strong></td>
</tr>
<tr>
<td>Response Time</td>
<td>Earth Resistance: Approx. 7 seconds<br />
AC Current: Approx. 2 seconds</td>
</tr>
<tr>
<td>Current Consumption</td>
<td>Approx. 50mA (max.100mA)</td>
</tr>
<tr>
<td>Measurement Time</td>
<td>R6: Approx. 5 hours<br />
LR6: Approx. 21 hours</td>
</tr>
<tr>
<td>Auto Power-Off</td>
<td>Turns power off about 10 minutes after the last button operation</td>
</tr>
<tr>
<td>Conductor Size</td>
<td>Approx. Ø32mm</td>
</tr>
<tr>
<td>Power Source</td>
<td>4 x R6 AA Manganese Batteries or<br />
4 x LR6 AA Alkaline Batteries</td>
</tr>
<tr>
<td>Dimensions</td>
<td>246 x 120 x 54 mm</td>
</tr>
<tr>
<td>Weight</td>
<td>Approx. 780 g (Including Batteries)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-4202-earth-clamp-tester/">KYORITSU 4202 Earth Clamp Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KYORITSU 4200 Digital TRMS Earth Resistance Clamp</title>
		<link>https://rapid-tech.com.au/kyoritsu-4200-digital-trms-earth-resistance-clamp/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Thu, 24 May 2018 15:00:27 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=7652</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-9900" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/Kyoritsu-Premium-Authorised.jpg" alt="" width="250" height="69" /></p>
<p>&#160;</p>
<p><a target="_blank" href="https://mymeter.com.au/product/kyoritsu-4200-digital-trms-earth-resistance-clamp/" rel="noopener"><img class="alignnone size-full wp-image-17843" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/BUY-NOW-form-My-Meter-e1620004827208.png" alt="Buy now form My Meter" width="220" height="55" /></a></p>
<h4><span style="font-size: 110%;">Save time with this earth resistance clamp - no need to lay out auxiliary spikes</span></h4>
<p>Capable of measuring earth resistance levels between a range of 0.05 and 1500Ω with high accuracy, it can also be used to gain a reading of AC current levels. The KYORITSU 4200 includes large jaws which are designed for clamping directly onto a targeted testing application.</p>
<h4>KEY BENEFITS</h4>
<ul>
<li>Save time with this earth resistance clamp - no need to lay out auxilary earth spikes</li>
<li>For measuring earth spikes in systems with multiple earthing points</li>
</ul>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="font-size: 110%;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-4200-Datasheet.pdf" rel="noopener"><span style="text-decoration: underline;">Kyoritsu 4200 Datasheet</span></a></span></h4>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><span style="font-size: 110%;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-4200-User-Manual.pdf" rel="noopener">Kyoritsu 4200 User Manual</a></span></span></h4>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-4200-digital-trms-earth-resistance-clamp/">KYORITSU 4200 Digital TRMS Earth Resistance Clamp</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>You can use the KYORITSU 4200 Digital TRMS Earth Resistance Clamp to carry out earth resistance testing procedures without the need to use auxiliary earth spikes.</p>
<div class="row"  id="row-1182641629">

	<div id="col-1898252605" class="col medium-2/3 large-8"  >
				<div class="col-inner"  >
			
			
<p>It is capable of measuring earth resistance levels between a range of 0.05 and 1200Ω with high accuracy, it can also be used to gain a reading of AC current levels. The KYORITSU 4200  includes large jaws which are designed for clamping directly onto a targeted testing application.</p>
<p>Calibration of the Kyoritsu 4200 can be checked before taking measurements by using the supplied Test Fixture/Resistor.</p>
		</div>
					</div>

	

	<div id="col-1999120770" class="col medium-1/3 large-4"  >
				<div class="col-inner"  >
			
			
<a href="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-4200-Cal.png"><img loading="lazy" decoding="async" class="alignnone wp-image-7656" src="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-4200-Cal.png" alt="" width="204" height="222" /></a></p>
		</div>
					</div>

	
</div>
<p>With built in noise checking, the KYORITSU 4200 Digital TRMS Earth Resistance Clamp is able to filter out noise problems and maintain accurate results. These results are also able to be stored directly on the tester (it features memory for 100 readings) and other additional features unique to this earth resistance clamp meter include a buzzer function, data hold and a backlit screen.</p>
<h4><span style="font-size: 110%;">KYORITSU 4200 Digital TRMS Earth Resistance Clamp Features:</span></h4>
<p style="padding-left: 30px;"><div class="row"  id="row-366518363">

	<div id="col-983975680" class="col medium-2/3 large-8"  >
				<div class="col-inner"  >
			
			
• The earth resistance from 0.05 to 1500Ω can be measured without the auxiliary earth spikes. (The Multiple Earthing System.)<br />
• True RMS &#8211; Accurate true RMS readings of AC current including distorted waveform from 1mA to 30.0A<br />
• Noise Check Function &#8211; A function to detect current, which effects on an earth resistance measurement and display &#8220;NOISE&#8221; mark on the LCD.<br />
• Memory function  &#8211; Save and display up to 100 measurement data.<br />
• Data hold function / Buzzer function / Back light function<br />
• Compliant with Safety Standards of IEC 61010-1 : CAT IV 300V Pollution degree2</p>
		</div>
					</div>

	

	<div id="col-251626006" class="col medium-1/3 large-4"  >
				<div class="col-inner"  >
			
			
<a href="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-4200-Hand.jpg"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-7655" src="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-4200-Hand.jpg" alt="" width="260" height="260" srcset="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-4200-Hand.jpg 260w, https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-4200-Hand-100x100.jpg 100w, https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-4200-Hand-150x150.jpg 150w" sizes="auto, (max-width: 260px) 100vw, 260px" /></a>..</p>
		</div>
					</div>

	
<p style="padding-left: 30px;"></div>
<h4><span style="font-size: 110%;">KYORITSU 4200 Digital TRMS Earth Resistance Clamp Specifications:</span></h4>
<table class="specTable mb0">
<tbody>
<tr>
<th>Earth resistance Auto range</th>
<td>20.00/200.0/1500Ω<br />
±1.5%±0.05Ω(0.00 &#8211; 20.99Ω)*<br />
±2%±0.5Ω(16.0 &#8211; 99.9Ω)<br />
±3%±2Ω(100.0 &#8211; 209.9Ω)<br />
±5%±5Ω(160 &#8211; 399Ω)<br />
±10%±10Ω(400 &#8211; 599Ω)</td>
</tr>
<tr>
<th>AC current (50Hz/60Hz) Auto range</th>
<td>Values are displayed, but accuracy isn&#8217;t guaranted(600 &#8211; 1580Ω)<br />
100.0/1000mA/10.00/30.0A<br />
±2%±0.7mA(0.0 &#8211; 104.9mA)<br />
±2%(80mA &#8211; 31.5A)</td>
</tr>
<tr>
<th>Operating indication</th>
<td>Earth resistance function :<br />
Constant voltage injection<br />
Current detection (Frequency : Approx.2400Hz)<br />
Dual Integration<br />
AC current function : Successive approximation</td>
</tr>
<tr>
<th>Over-range indication</th>
<td>&#8220;OL&#8221;is displayed when input exceeds the upper limit of a measuring range</td>
</tr>
<tr>
<th>Response time</th>
<td>Approx. 7 seconds (Earth resistance)<br />
Approx. 2 seconds (AC current)</td>
</tr>
<tr>
<th>Sample rate</th>
<td>Approx. 1 times per second</td>
</tr>
<tr>
<th>Current consumption</th>
<td>Approx. 50mA (max.100mA)</td>
</tr>
<tr>
<th>Measurement time</th>
<td>Approx.12 hours (when R6 is used)<br />
Approx.24 hours (when LR6 is used)</td>
</tr>
<tr>
<th>Auto power-off</th>
<td>Turns power off about 10 minutes after the last button operation.</td>
</tr>
<tr>
<th>Conductor size</th>
<td>Approx. Ø32mm</td>
</tr>
<tr>
<th>Applicable standards</th>
<td>IEC 61010-1 CAT Ⅳ 300V Pollution degree2<br />
IEC 61010-2-032, IEC 61326 (EMC)</td>
</tr>
<tr>
<th>Power source</th>
<td>DC6V : R6(sizeAA manganese battery) x 4<br />
or LR6 (sizeAA alkaline battery) x 4</td>
</tr>
<tr>
<th>Dimensions</th>
<td>246(L)×120(W)×54(D)mm</td>
</tr>
<tr>
<th>Weight</th>
<td>Approx. 780g (including batteries)</td>
</tr>
<tr>
<th>Included Accessories</th>
<td>R6 x 4, Instruction manual<br />
8304 (Resister for operation check)<br />
9166 (Carrying case[Hard])</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-4200-digital-trms-earth-resistance-clamp/">KYORITSU 4200 Digital TRMS Earth Resistance Clamp</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Kyoritsu 4106 Earth &#038; Ground Resistance Tester</title>
		<link>https://rapid-tech.com.au/kyoritsu-4106-earth-ground-resistance-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Fri, 09 Mar 2018 05:18:03 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=6331</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-9900" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/Kyoritsu-Premium-Authorised.jpg" alt="" width="250" height="69" /></p>
<p>Kyoritsu 4106 is a 2/ 3/ 4-wire digital earth resistance/earth resistivity tester, equipped with a microcomputer, for measuring earth resistances and calculating earth resistivities.<br />
It has an output voltage of 10 Vrms or lower. This makes it an instrument of choice for measuring earth resistances on installations ranging from in-house wiring systems and electrical appliances to power distribution lines.<br />
Sub-results that can be shown on the display include resistance of the auxiliary earth spikes, frequency of test current, voltage and frequency of interference (noise) and residual resistance Rk.</p>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><span style="color: #ff0000; font-size: 110%;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2018/03/Kyoritsu-4106-Datasheet.pdf" rel="noopener">Kyoritsu 4106 Datasheet</a></span></span></h4>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><span style="font-size: 110%;"><strong><span style="color: #ff0000;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2018/03/Kyoritsu-4106-User-Manual.pdf" rel="noopener">Kyoritsu 4106 User Manual</a></span></strong></span></span></h4>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-4106-earth-ground-resistance-tester/">Kyoritsu 4106 Earth &#038; Ground Resistance Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3 class="headLine5">Kyoritsu 4106 Earth &amp; Ground Resistance Tester</h3>
<p>• High test current up to 80mA yielding resolution of 0.001Ω on 2Ω range.<br />
• Advanced Filtering method (based on FFT Fast Fourier Transform) reduces noise interference for obtaining stable measurements.<br />
• Automatic and Manual selection of the Test Current Frequency in four bands (94/105/111/128Hz). In Automatic mode, KEW 4106 will select the most suitable Frequency.<br />
• Several sub-results can be shown on the display: Resistance of the Auxiliary Earth Spikes, Frequency of Test Current, Voltage and Frequency of Interference (noise), Residual Resistance Rk, etc.<br />
• Warning for excessive noise and high Auxiliary Earth Spikes resistance.<br />
• Large Graphic Display with backlight for readings in poorly illuminated areas.<br />
• Up to 800 measurement results can be saved in the memory and recalled on the display.<br />
• The stored results can be transferred to a PC using the &#8220;KEW Report&#8221; software and a USB adaptor (Model 8212-USB) which are included.<br />
• Robust design with IP54 protection.</p>
<h3 style="text-align: center;">Earth Resistance Measurements with 4, 3 and 2 Wires</h3>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2018/03/KYORITSU-4106-Panel.jpg"><img loading="lazy" decoding="async" class="size-full wp-image-6332 aligncenter" src="https://rapid-tech.com.au/wp-content/uploads/2018/03/KYORITSU-4106-Panel.jpg" alt="" width="983" height="244" srcset="https://rapid-tech.com.au/wp-content/uploads/2018/03/KYORITSU-4106-Panel.jpg 983w, https://rapid-tech.com.au/wp-content/uploads/2018/03/KYORITSU-4106-Panel-300x74.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2018/03/KYORITSU-4106-Panel-600x149.jpg 600w, https://rapid-tech.com.au/wp-content/uploads/2018/03/KYORITSU-4106-Panel-768x191.jpg 768w" sizes="auto, (max-width: 983px) 100vw, 983px" /></a></p>
<h3>Kyoritsu 4106 Earth &amp; Ground Resistance Tester Specifications:</h3>
<div class="editor">
<div class="tableScroller">
<table>
<tbody>
<tr>
<th>Function</th>
<th>Range</th>
<th>Resolution</th>
<th>Measuring range</th>
<th>Accuracy</th>
</tr>
<tr>
<th rowspan="6">Earth resistance<br />
Re<br />
(Rg at<br />
ρ measurement)</th>
<td>2Ω</td>
<td>0.001Ω</td>
<td>0.03 &#8211; 2.099Ω</td>
<td>±2%rdg±0.03Ω</td>
</tr>
<tr>
<td>20Ω</td>
<td>0.01Ω</td>
<td>0.03 &#8211; 20.99Ω</td>
<td rowspan="5">±2%rdg±5dgt (*1)</td>
</tr>
<tr>
<td>200Ω</td>
<td>0.1Ω</td>
<td>0.3 &#8211; 209.9Ω</td>
</tr>
<tr>
<td>2000Ω</td>
<td>1Ω</td>
<td>3 &#8211; 2099Ω</td>
</tr>
<tr>
<td>20kΩ</td>
<td>10Ω</td>
<td>0.03k &#8211; 20.99kΩ</td>
</tr>
<tr>
<td>200kΩ</td>
<td>100Ω</td>
<td>0.3k &#8211; 209.9kΩ</td>
</tr>
<tr>
<th>Auxiliary earth resistance<br />
Rh, Rs</th>
<td></td>
<td></td>
<td></td>
<td>8% of Re+Rh+Rs</td>
</tr>
<tr>
<th rowspan="6">Earth resistivity<br />
ρ</th>
<td>2Ω</td>
<td rowspan="6">0.1Ω·mm &#8211; 1Ω·m<br />
Autoranging</td>
<td>0.2 &#8211; 395.6Ω·m</td>
<td rowspan="6">ρ=2×π×a×Rg (*2)</td>
</tr>
<tr>
<td>20Ω</td>
<td>0.2 &#8211; 3956Ω·m</td>
</tr>
<tr>
<td>200Ω</td>
<td>20 &#8211; 39.56kΩ·m</td>
</tr>
<tr>
<td>2000Ω</td>
<td>0.2 &#8211; 395.6kΩ·m</td>
</tr>
<tr>
<td>20kΩ</td>
<td rowspan="2">2.0 &#8211; 1999kΩ·m</td>
</tr>
<tr>
<td>200kΩ</td>
</tr>
<tr>
<th rowspan="2">Series interference voltage<br />
Ust (A.C only) (*3)</th>
<td rowspan="2">50V</td>
<td rowspan="2">0.1V</td>
<td rowspan="2">0 &#8211; 50.9Vrms</td>
<td>±2%rdg±2dgt (50/60Hz)</td>
</tr>
<tr>
<td>±3%rdg±2dgt (40 &#8211; 500Hz)</td>
</tr>
<tr>
<th>Frequency<br />
Fst</th>
<td>Autoranging</td>
<td>0.1Hz<br />
1Hz</td>
<td>40Hz &#8211; 500Hz</td>
<td>±1%rdg±2dgt</td>
</tr>
<tr>
<th>Measuring method</th>
<td colspan="4">Earth resistance: Fall-of-potential method<br />
(currents and voltages measured via the Probes)<br />
Measurement method of Earth Resistivity (ρ): Wenner 4-pole method<br />
Series interference voltage (earth voltage)<br />
RMS Rectifier (between the E-S Terminals)</td>
</tr>
<tr>
<th>Memory capacity</th>
<td colspan="4">800 data</td>
</tr>
<tr>
<th>Communication Interface</th>
<td colspan="4">Model 8212-USB Optical Adaptor</td>
</tr>
<tr>
<th>LCD</th>
<td colspan="4">Dot-matrix 192×64 monochrome</td>
</tr>
<tr>
<th>Over-range Indication</th>
<td colspan="4">&#8220;OL&#8221;</td>
</tr>
<tr>
<th>Overload Protection</th>
<td colspan="4">between E-S(P) and between E-H(C) terminals AC280V / 10 sec.</td>
</tr>
<tr>
<th>Applicable standards</th>
<td colspan="4">IEC 61010-1 CAT III 300V, CAT IV 150V Pollution degree 2<br />
IEC 61010-031, IEC 61557-1, 5, IEC 61326-1 (EMC), IEC 60529 (IP54)</td>
</tr>
<tr>
<th>Power source</th>
<td colspan="4">DC12V : sizeAA manganese dry battery (R6) × 8<br />
(Auto power off: approx. 5 minutes)</td>
</tr>
<tr>
<th>Dimensions</th>
<td colspan="4">167(L) × 185(W) × 89(D) mm</td>
</tr>
<tr>
<th>Weight</th>
<td colspan="4">approx. 900g (including batteries)</td>
</tr>
<tr>
<th>Accessories</th>
<td colspan="4">7229A (Earth precision measurement),<br />
7238A (Simplified measurement test leads),<br />
8032 (Auxiliary earth spikes [2 spiks/set])×2 sets (4 spikes in total),<br />
8200-04 (Cord reel [4 pcs])×1 set,<br />
8212-USB (USB adaptor with &#8220;KEW Report(Software)&#8221;),<br />
9121 (Shoulder strap),<br />
9125 (Carrying case),<br />
R6 × 8, Instruction manual, Calibration certificate</td>
</tr>
<tr>
<th>Optional</th>
<td colspan="4">8212-RS232C (RS232C adaptor with &#8220;KEW Report(Software)&#8221;)</td>
</tr>
</tbody>
</table>
</div>
</div>
<section class="mb10"></section>
<div class="editor">
<p>(*1) Auxiliary earth resistance is 100Ω with Rk correction<br />
(*2) Depending on the measured Rg. Interval [a] between auxiliary earth spikes is 1.0 &#8211; 30.0m<br />
(*3) This instrument is NOT designed to measure line voltages on commercial powers.</p>
</div>
<p>&nbsp;</p>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-4106-earth-ground-resistance-tester/">Kyoritsu 4106 Earth &#038; Ground Resistance Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Kyoritsu 6016 Multi Function Electrical Tester</title>
		<link>https://rapid-tech.com.au/kyoritsu-6016-multi-function-electrical-testers/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Fri, 09 Mar 2018 00:57:53 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=6324</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-9900" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/Kyoritsu-Premium-Authorised.jpg" alt="" width="250" height="69" /></p>
<p><a target="_blank" href="https://mymeter.com.au/product/kyoritsu-6016-multi-function-electrical-tester/" rel="noopener noreferrer"><img class="aligncenter wp-image-16672 size-full" src="https://rapid-tech.com.au/wp-content/uploads/2020/01/Buy-Now-Flir-Direct-sm.jpg" alt="" width="200" height="49" /></a></p>
<h3 style="text-align: center;"><strong>Kyoritsu 6016 Multi Function Tester Features:</strong></h3>
<p>&#160;</p>
<p style="text-align: center;"><a href="https://rapid-tech.com.au/wp-content/uploads/2018/03/Kyoritsu-6016-10-1.gif"><img class="alignnone size-full wp-image-6325" src="https://rapid-tech.com.au/wp-content/uploads/2018/03/Kyoritsu-6016-10-1.gif" alt="" width="200" height="301" /></a></p>
<ul>
<li><strong>10 in 1 Tester</strong> - Continuity, Insulation, Loop, PSC, PFC, RCD, Earth, Phase Rotation, Volts and Frequency Testing</li>
<li>Advanced Anti-Trip Technology (ATT) for avoiding RCDs trip during loop testing.</li>
<li>A single rotary dial to make selection of test and measurement functions</li>
<li>Slim remote probe with test button as well as a lockdown option on the instrument for the most convenient hands free testing.</li>
<li>Safety test leads have an overmould for maximum grip and are extremely robust.</li>
<li>PC software for downloading and interpreting of data and interface cable are included.</li>
<li>Soft carry case included to store instrument and all the test leads.</li>
</ul>
<p>&#160;</p>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="color: #0000ff;"><a href="https://rapid-tech.com.au/wp-content/uploads/2018/03/Kyoritsu-6016-Datasheet.pdf">Kyoritsu 6016 Datasheet</a></span></h3>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-6016-multi-function-electrical-testers/">Kyoritsu 6016 Multi Function Electrical Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Kyoritsu 6016 Multi Function Electrical Tester Functions:</h3>
<p style="text-align: center;"><a href="https://rapid-tech.com.au/wp-content/uploads/2018/03/Kyoritsu-6016-10-Buttons.jpg"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-6330" src="https://rapid-tech.com.au/wp-content/uploads/2018/03/Kyoritsu-6016-10-Buttons.jpg" alt="" width="819" height="109" srcset="https://rapid-tech.com.au/wp-content/uploads/2018/03/Kyoritsu-6016-10-Buttons.jpg 819w, https://rapid-tech.com.au/wp-content/uploads/2018/03/Kyoritsu-6016-10-Buttons-300x40.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2018/03/Kyoritsu-6016-10-Buttons-600x80.jpg 600w, https://rapid-tech.com.au/wp-content/uploads/2018/03/Kyoritsu-6016-10-Buttons-768x102.jpg 768w" sizes="auto, (max-width: 819px) 100vw, 819px" /></a></p>
<p><strong>Continuity Measurement </strong><br />
With the Kyoritsu 6016 Multi Function Electrical Tester continuity testing can be carried out by use of the test button lockdown feature. A selectable buzzer gives instantaneous indication of continuity. Null facility eliminates the test lead resistance from the results, the nulled value is retained even if the instrument is switched off. Live circuit warnings are given by a flashing LED, buzzer and indication on the display.</p>
<p><strong>Insulation Measurement </strong><br />
The Kyoritsu 6016 Multi Function Electrical Tester has three selectable test voltages <strong>250V, 500V and 1000V.</strong> An auto-discharge function ensures that circuits are not hazardous after testing. A red LED gives warning of high voltage output during testing and discharging of the circuit. In case of connecting to a live circuit, a live circuit warning is given by flashing LED, buzzer and indication on the display.</p>
<p><strong>Loop Impedance Measurement</strong><br />
The Kyoritsu 6016 Multi Function Electrical TesterA patented (ATT) low current loop impedance test enables high accuracy loop measurements and quick testing without tripping RCD&#8217;s.<br />
A high current alternative is selectable for even higher accuracy and instantaneous results. The subsequent test will default to the low current test, this saves any inadvertent tripping of the RCD. The KEW 6016 allows also for phase to phase loop tests.</p>
<p><strong>PSC / PFC Measurement </strong><br />
The Prospective Short Circuit Current (PSC) and Prospective Fault Current (PFC) are automatically calculated and shown on the display. As loop testing, the function has low and high test current options with the default to low current to avoid inadvertent tripping of RCDs.</p>
<p><strong>RCD Measurement </strong><br />
The KEW 6016 has a comprehensive RCD test feature for RCD type AC (Alternative Currents), RCD type A (Pulsating Direct Currents), General and Selective (delayed).<br />
Measures at 1/2x, 1x, 5x of nominal RCD current. It also has Ramp Test and Auto test where all results are shown on one screen. Touch voltage limit can be selected for 25V or 50V depending on application</p>
<p><strong>Earth Measurement </strong><br />
Using the classical Volt-Amper method with two auxiliary earth spikes and without external power source. All test leads and spikes are supplied as standard accessories.</p>
<p><strong>Phase rotation </strong><br />
KEW 6016 can check the phase rotation of three phase lines with clear indication of the sequence on the display.</p>
<p><strong>Voltage Measurement </strong><br />
In addiction to the voltage measurement, this function gives also the Frequency of the voltage under test.</p>
<h3>Kyoritsu 6016 Multi Function Electrical Tester Specifications:</h3>
<div class="editor">
<div class="tableScroller">
<table>
<tbody>
<tr>
<th colspan="8"><span style="color: #ed1c24;">Continuity</span></th>
</tr>
<tr>
<th>Range</th>
<td colspan="7">20/200/2000Ω (Auto-ranging)</td>
</tr>
<tr>
<th> Open circuit<br />
voltage (DC)</th>
<td colspan="7">5V±20% (*1)</td>
</tr>
<tr>
<th>Short circuit<br />
current</th>
<td colspan="7">Greater than 200mA</td>
</tr>
<tr>
<th>Accuracy</th>
<td colspan="7">±0.1Ω (0 &#8211; 0.19Ω)<br />
±2%rdg+8dgt (0.2 &#8211; 2000Ω)</td>
</tr>
<tr>
<th colspan="8"><span style="color: #ed1c24;">Insulation Resistance</span></th>
</tr>
<tr>
<th>Range</th>
<td colspan="4">20/200MΩ<br />
(Auto-ranging)</td>
<td colspan="3">20/200/2000MΩ (Auto-ranging)</td>
</tr>
<tr>
<th>Open circuit<br />
voltage (DC)</th>
<td colspan="4">250V+25% -0%</td>
<td>500V+25% -0%</td>
<td colspan="2">1000V+20% -0%</td>
</tr>
<tr>
<th>Rated current</th>
<td colspan="4">1mA or greater<br />
@ 250kΩ</td>
<td>1mA or greater<br />
@ 500kΩ</td>
<td colspan="2">1mA or greater<br />
@ 1MΩ</td>
</tr>
<tr>
<th>Accuracy</th>
<td colspan="4">±2%rdg+6dgt<br />
(0 &#8211; 19.99MΩ)<br />
±5%rdg+6dgt<br />
(20 &#8211; 200MΩ)</td>
<td colspan="3">±2%rdg+6dgt (0 &#8211; 199.9MΩ)<br />
±5%rdg+6dgt (200 &#8211; 2000MΩ)</td>
</tr>
<tr>
<th colspan="8"><span style="color: #ed1c24;">Loop Impedance</span></th>
</tr>
<tr>
<th>Function</th>
<td colspan="4">L-PE</td>
<td>L-PE (ATT)</td>
<td colspan="2">L-N / L-L</td>
</tr>
<tr>
<th>Rated Voltage</th>
<td colspan="5">100 &#8211; 260V 50/60Hz</td>
<td colspan="2">L-N: 100 &#8211; 300V<br />
L-L: 300 &#8211; 500V<br />
50/60Hz</td>
</tr>
<tr>
<th>Nominal Test<br />
Current at 0Ω<br />
External Loop:<br />
Magnitude/<br />
Duration (*2)</th>
<td colspan="4">20Ω: 6A/20ms<br />
200Ω: 2A/20ms<br />
2000Ω: 15mA/500ms</td>
<td>L-N: 6A/60ms<br />
N-PE: 10mA/approx. 5s</td>
<td colspan="2">20Ω: 6A/20ms</td>
</tr>
<tr>
<th>Range</th>
<td colspan="4">20/200/2000Ω<br />
(Auto-ranging)</td>
<td>20/200/2000Ω<br />
(Auto-ranging)<br />
(L-N &lt; 20Ω)</td>
<td colspan="2">20Ω</td>
</tr>
<tr>
<th>Accuracy</th>
<td colspan="4">±3%rdg+4dgt(*3)<br />
±3%rdg+8dgt(*4)</td>
<td>±3%rdg+6dgt (*3)<br />
±3%rdg+8dgt(*4)</td>
<td colspan="2">±3%rdg+4dgt (*3)<br />
±3%rdg+8dgt(*4)</td>
</tr>
<tr>
<th colspan="8"><span style="color: #ed1c24;">PSC (L-N / L-L) / PFC (L-PE)</span></th>
</tr>
<tr>
<th>Function</th>
<td colspan="4">PSC</td>
<td>PFC</td>
<td colspan="2">PFC (ATT)</td>
</tr>
<tr>
<th>Rated Voltage</th>
<td colspan="4">100 &#8211; 500V 50/60Hz</td>
<td>100 &#8211; 260V 50/60Hz</td>
<td colspan="2"></td>
</tr>
<tr>
<th>Nominal Test<br />
Current at 0Ω<br />
External Loop:<br />
Magnitude/<br />
Duration (*5)</th>
<td colspan="4">6A/20ms</td>
<td>6A/20ms<br />
2A/20ms<br />
15mA/500ms</td>
<td colspan="2">L-N: 6A/60ms<br />
N-PE: 10mA/approx. 5s</td>
</tr>
<tr>
<th> Range</th>
<td colspan="7">2000A/20kA Auto-Ranging</td>
</tr>
<tr>
<th>Accuracy</th>
<td colspan="7">PSC / PFC accuracy is derived from measured loop impedance<br />
specification and measured voltage specification</td>
</tr>
<tr>
<th colspan="8"><span style="color: #ed1c24;">RCD</span></th>
</tr>
<tr>
<th>Function</th>
<td colspan="2">X1/2</td>
<td colspan="2">X1</td>
<td>X5</td>
<td>Ramp</td>
<td>Auto</td>
</tr>
<tr>
<th>Trip current<br />
setting</th>
<td colspan="4">10/30/100/300/<br />
500/1000mA</td>
<td>10/30/<br />
100mA</td>
<td>10/30/<br />
100/300/<br />
500mA</td>
<td rowspan="5">Depending on the<br />
accuracy at each<br />
function.<br />
Measurement sequence:<br />
X1/2 0°→X1/2 180°<br />
→X1 0°→X1 180°<br />
→X5 0°→X5 180°<br />
Measurements with<br />
x5 are not carried out<br />
for RCDs with<br />
nominal current of<br />
100mA or more.</td>
</tr>
<tr>
<th>Trip current<br />
Duration</th>
<td colspan="2">2000ms</td>
<td colspan="2">G: 550ms<br />
S: 1000ms</td>
<td>410ms</td>
<td>Goes up by<br />
10% from<br />
20% to<br />
110%<br />
G:300ms/<br />
S:500ms<br />
X10 times</td>
</tr>
<tr>
<th>Rated Voltage</th>
<td colspan="6">230V+10%-15% 50/60Hz</td>
</tr>
<tr>
<th rowspan="2">Accuracy</th>
<td colspan="2">AC Type:<br />
-8% &#8211; -2%<br />
A Type:<br />
-10% &#8211; 0%</td>
<td colspan="3">AC Type: +2% &#8211; +8%<br />
A Type: 0% &#8211; +10%</td>
<td>AC Type: ±4%<br />
A Type: ±10%</td>
</tr>
<tr>
<td colspan="6">Trip time: ±1%rdg+3dgt</td>
</tr>
<tr>
<th colspan="9"><span style="color: #ed1c24;">RCD (Uc)</span></th>
</tr>
<tr>
<th>Function</th>
<td colspan="8">UC</td>
</tr>
<tr>
<th>Rated Voltage</th>
<td colspan="8">230V+10% &#8211; 15% 50/60Hz</td>
</tr>
<tr>
<th>Range</th>
<td colspan="8">100.0V</td>
</tr>
<tr>
<th>Test current</th>
<td colspan="8">≤ 1/2IΔn (max150mA)</td>
</tr>
<tr>
<th>Accuracy</th>
<td colspan="8">+5% &#8211; +15%rdg, ±8dgt</td>
</tr>
<tr>
<th colspan="9"><span style="color: #ed1c24;">Earth</span></th>
</tr>
<tr>
<th>Range</th>
<td colspan="8">20/200/2000Ω Auto-Ranging</td>
</tr>
<tr>
<th>Accuracy</th>
<td colspan="8">20Ω: ±3%rdg+0.1Ω<br />
200/2000Ω: ±3%rdg+3dgt (Auxiliary earth resistance 100±5%)</td>
</tr>
<tr>
<th colspan="9"><span style="color: #ed1c24;">Phase Rotation</span></th>
</tr>
<tr>
<th>Rated Voltage</th>
<td colspan="8">50-500V 50/60Hz</td>
</tr>
<tr>
<th>Remarks</th>
<td colspan="8">Correct phase sequence: are displayed &#8220;1.2.3&#8221; and <img loading="lazy" decoding="async" src="https://www.kew-ltd.co.jp/files/en/img/recycle_right.gif" width="20" height="20" /> cycle mark<br />
Reversed phase sequence: are displayed &#8220;3.2.1&#8221; and <img loading="lazy" decoding="async" src="https://www.kew-ltd.co.jp/files/en/img/recycle_right.gif" width="20" height="20" /> cycle mark</td>
</tr>
<tr>
<th colspan="9"><span style="color: #ed1c24;">Volts</span></th>
</tr>
<tr>
<th>Function</th>
<td colspan="5">Volts</td>
<td colspan="3">Frequency</td>
</tr>
<tr>
<th>Rated Voltage</th>
<td colspan="8">25 &#8211; 500V, 45 &#8211; 65Hz</td>
</tr>
<tr>
<th>Measuring range</th>
<td colspan="5">25 &#8211; 500V</td>
<td colspan="3">45 &#8211; 65Hz</td>
</tr>
<tr>
<th>Accuracy</th>
<td colspan="5">±2%rdg+4dgt</td>
<td colspan="3">±0.5%rdg+2dgt</td>
</tr>
</tbody>
</table>
</div>
</div>
<section class="mb10">
<table class="specTable mb0">
<tbody>
<tr>
<th>Applicable standards</th>
<td>IEC 61010-1 CAT III 300V (500V L to L) Pollution degree 2, IEC 61010-031,<br />
IEC 61557-1, 2, 3, 4, 5, 6, 7, 10, IEC 60529 (IP40), IEC 61326 (EMC)</td>
</tr>
<tr>
<th>Power source</th>
<td>LR6 X 8</td>
</tr>
<tr>
<th>Dimensions</th>
<td>136(L) X 235(W) X 114(D)mm</td>
</tr>
<tr>
<th>Weight</th>
<td>1350g (including batteries.)</td>
</tr>
<tr>
<th>Included Accessories</th>
<td>7188A (Distribution board fuse test lead set)<br />
7196A (Test leads with remote control switch)<br />
7218A (Power cord [AU) (*6)<br />
7228A (Earth resistance test leads)<br />
8032 (Auxiliary earth spikes)<br />
8212-USB (USB adaptor with KEW Report (Software))<br />
9142 (Carrying case)<br />
9121 (Shoulder strap)<br />
Cord case, Buckle, Battery, Instruction manual</td>
</tr>
<tr>
<th>Optional Accessories</th>
<td>8212-RS232C (RS232C adaptor with KEW Report (Software))</td>
</tr>
</tbody>
</table>
</section>
<div class="editor">
<p>(*1): Voltages are output when measurement resistance is under 2100 ohm.<br />
(*2): at 230V<br />
(*3): 230V+10%-15%<br />
(*4): voltages except for (*3)<br />
(*5): at 230V<br />
(*6): 7187A (Power cord [UK]), 7221A (Power cord [SA]), <strong>7222A (Power cord [AU])</strong></p>
<p><a target="_blank" href="https://mymeter.com.au/product/kyoritsu-6016-multi-function-electrical-tester/" rel="noopener noreferrer"><img loading="lazy" decoding="async" class="aligncenter wp-image-16672 size-full" src="https://rapid-tech.com.au/wp-content/uploads/2020/01/Buy-Now-Flir-Direct-sm.jpg" alt="" width="200" height="49" /></a></p>
</div>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-6016-multi-function-electrical-testers/">Kyoritsu 6016 Multi Function Electrical Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Kyoritsu 4105DL Earth Tester</title>
		<link>https://rapid-tech.com.au/kyoritsu-4105dl-earth-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Fri, 10 Nov 2017 03:44:22 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=5872</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-7630" src="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-Authorised.jpg" alt="" width="250" height="69" /></p>
<p><a target="_blank" href="https://mymeter.com.au/product/kyoritsu-4105dl-earth-tester/" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<p class="headLine5"><strong>4105DL</strong> [Cable Reel Set Model]<br />
<strong>4105DL</strong>-H [Hard Case Model]</p>
<p>• 3 pole and 2 pole Earth Resistance measurement (0.01Ω-2000Ω)<br />
• Waterproof design (IP67)<br />
• Rotary Switch makes the user interface very intuitive<br />
• Large LCD Display with Backlight<br />
• Led to monitor correct / non correct auxiliary earth spike resistance<br />
• Earth Voltage Measurement (AC/DC 0-300V)<br />
• CAT Ⅳ - 100V</p>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>   <span style="color: #0000ff;"> <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2017/11/Kyoritsu-4105DL-Datasheet.pdf" rel="noopener">Kyoritsu 4105DL Datasheet</a></span></h4>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-4105dl-earth-tester/">Kyoritsu 4105DL Earth Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4><span style="font-size: 110%;">Kyoritsu 4105DL Earth Tester Features:</span></h4>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/KEW-4105DL-Measurements.jpg"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-5876" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/KEW-4105DL-Measurements.jpg" alt="" width="884" height="698" srcset="https://rapid-tech.com.au/wp-content/uploads/2017/11/KEW-4105DL-Measurements.jpg 884w, https://rapid-tech.com.au/wp-content/uploads/2017/11/KEW-4105DL-Measurements-300x237.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2017/11/KEW-4105DL-Measurements-600x474.jpg 600w, https://rapid-tech.com.au/wp-content/uploads/2017/11/KEW-4105DL-Measurements-768x606.jpg 768w" sizes="auto, (max-width: 884px) 100vw, 884px" /></a></p>
<table>
<tbody>
<tr>
<th colspan="2">Earth resistance<br />
measurement</th>
<th colspan="2">20Ω</th>
<th colspan="2">200Ω</th>
<th colspan="2">2000Ω</th>
</tr>
<tr>
<th rowspan="5"></th>
<th>Measuring range</th>
<td colspan="6">0.00 &#8211; 2000 Ω</td>
</tr>
<tr>
<th>Display range</th>
<td colspan="2">0.00 &#8211; 20.99 Ω</td>
<td colspan="2">0.0 &#8211; 209.9 Ω</td>
<td colspan="2">0 &#8211; 2099 Ω</td>
</tr>
<tr>
<th>Accuracy*1</th>
<td colspan="2">±1.5%rdg±0.08 Ω*2</td>
<td colspan="4">±1.5%rdg±4dgt</td>
</tr>
<tr>
<th>Auxiliary earth resistance*3</th>
<td colspan="2">&lt;10kΩ</td>
<td colspan="2"> &lt;50kΩ</td>
<td colspan="2"> &lt;100kΩ</td>
</tr>
<tr>
<th>Comparator reference value</th>
<td colspan="2">10Ω</td>
<td colspan="2"> 100Ω</td>
<td colspan="2"> 500Ω</td>
</tr>
<tr>
<th colspan="8">Earth voltage measurement</th>
</tr>
<tr>
<th rowspan="3"></th>
<th>Measuring range</th>
<td colspan="3">0 &#8211; 300 V AC (45 &#8211; 65Hz)</td>
<td colspan="3">±0 &#8211; ±300 V DC</td>
</tr>
<tr>
<th>Display range</th>
<td colspan="3">0.0 &#8211; 314.9 V</td>
<td colspan="3">0.0 &#8211; ±314.9 V</td>
</tr>
<tr>
<th>Accuracy</th>
<td colspan="6">±1%rdg±4dgt</td>
</tr>
<tr>
<th colspan="2" rowspan="2">Overload protection</th>
<td colspan="6">Earth resistance : 360V AC (10 seconds)</td>
</tr>
<tr>
<td colspan="6">Earth voltage : 360V AC (10 seconds)</td>
</tr>
<tr>
<th colspan="2" rowspan="3">Applicable Standards</th>
<td colspan="6">IEC 61010-1, CAT IV 100 V /CAT III 150 V /CAT II 300 V Pollution degree 3</td>
</tr>
<tr>
<td colspan="6">IEC 61010-2-030,IEC 61010-031, IEC 61557-1, -5</td>
</tr>
<tr>
<td colspan="6">IEC 60529 IP67, IEC 61326-1, -2-2, EN50581(RoHS)</td>
</tr>
<tr>
<th colspan="2">Power source</th>
<td colspan="6">LR6(AA)(1.5V) × 6</td>
</tr>
<tr>
<th colspan="2">Dimensions</th>
<td colspan="6">121(L) × 188(W) × 59(H) mm (including case lid)</td>
</tr>
<tr>
<th colspan="2">Weight</th>
<td colspan="6">Approx. 690g (including batteries and case lid)</td>
</tr>
<tr>
<th colspan="2" rowspan="8">Accessories<br />
for 4105DL</th>
<td colspan="6">7127B(Simplified measurement probe)</td>
</tr>
<tr>
<td colspan="6">8041(Auxiliary earth spikes[2 spikes/1set])</td>
</tr>
<tr>
<td colspan="6">9121(Shoulder strap)</td>
</tr>
<tr>
<td colspan="6">7267(Cable reel for Earth resistance tester (red))</td>
</tr>
<tr>
<td colspan="6">7268(Cable reel for Earth resistance tester (yellow))</td>
</tr>
<tr>
<td colspan="6">7271(Earth resistance test leads)</td>
</tr>
<tr>
<td colspan="6">9190(Carrying case)</td>
</tr>
<tr>
<td colspan="6">LR6(AA) × 6, Instruction manual</td>
</tr>
<tr>
<th colspan="2" rowspan="6">Accessories<br />
for 4105DL-H</th>
<td colspan="6">7127B(Simplified measurement probe)</td>
</tr>
<tr>
<td colspan="6">8041(Auxiliary earth spikes[2 spikes/1set])</td>
</tr>
<tr>
<td colspan="6">9121(Shoulder strap)</td>
</tr>
<tr>
<td colspan="6">7266(Earth resistance test leads[red-20m, yellow-10m, green-5m/1set])</td>
</tr>
<tr>
<td colspan="6">9191(Hard case)</td>
</tr>
<tr>
<td colspan="6">LR6(AA) × 6, Instruction manual</td>
</tr>
<tr>
<th colspan="2" rowspan="2">Optional</th>
<td colspan="6">7272(Precision measurement Cord set)</td>
</tr>
<tr>
<td colspan="6">8259(Adapter for measurement terminal)</td>
</tr>
</tbody>
</table>
<p>*1 For precision measurement, auxiliary earth resistance should be 100 Ω ±5% or less.<br />
*2 At simplified measurement add ±0.10 Ω to the specified accuracy.<br />
*3 Accuracy within the auxiliary earth resistance: ±5% rdg ±10 dgt.</p>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-4105dl-earth-tester/">Kyoritsu 4105DL Earth Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Kyoritsu 4105A-H Earth Tester &#8211; Hard Case Model</title>
		<link>https://rapid-tech.com.au/kyoritsu-4105a-h-earth-tester-hard-case-model/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Wed, 30 Aug 2017 06:48:01 +0000</pubDate>
				<guid isPermaLink="false">http://rapid-tech.com.au/?post_type=product&#038;p=5444</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-Authorised.jpg"><img class="alignnone size-full wp-image-7630" src="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-Authorised.jpg" alt="" width="250" height="69" /></a></p>
<p>The Kyoritsu 4105A-H digital tester performs three-pole earth resistance and two-pole voltage testing of electrical equipment and systems wiring and grounding to reduce power quality issues and avoid safety hazards.</p>
<p>The meter is small and lightweight, with shock-resistant case material and taut-band movement. The OK light verifies proper connection between auxiliary earth resistance and lead wire connection to terminals.</p>
<p>The tester warns the user when the resistance of auxiliary earth spikes exceeds tolerance. Ground-resistance meters are used by electricians and contractors working in industrial, utility, and field servicing.</p>
<h3><a href="http://rapid-tech.com.au/wp-content/uploads/2017/05/pdf_sml-1.png"><img class="alignnone size-full wp-image-5149" src="http://rapid-tech.com.au/wp-content/uploads/2017/05/pdf_sml-1.png" alt="pdf_sml" width="40" height="40" /></a>    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a href="http://rapid-tech.com.au/wp-content/uploads/2017/08/Kyoritsu-4102A_4105A-Datasheet-1.pdf">Kyoritsu 4102A_4105A Datasheet</a></span></span></h3>
<h3><a href="http://rapid-tech.com.au/wp-content/uploads/2017/05/pdf_sml-1.png"><img class="alignnone size-full wp-image-5149" src="http://rapid-tech.com.au/wp-content/uploads/2017/05/pdf_sml-1.png" alt="pdf_sml" width="40" height="40" /></a>    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a href="http://rapid-tech.com.au/wp-content/uploads/2017/08/Kyoritsu-4105A-User-Manual.pdf">Kyoritsu 4105A User Manual</a></span></span></h3>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-4105a-h-earth-tester-hard-case-model/">Kyoritsu 4105A-H Earth Tester &#8211; Hard Case Model</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Kyoritsu 4105A-H Earth Tester test the condition of a grounding system, and provide resistivity measurements in ohms. Grounding systems protect people and equipment, and provide a safe path for the dissipation of fault currents, lightning strikes, static discharges, EMI and RFI signals, and interference.</p>
<p>Regular testing of a grounding system is important for safety and protection of equipment. For example, corrosive soil with high moisture content can degrade ground rods and connections in existing systems and increase the resistance of the system.</p>
<p>Ground-resistance meters are used in conjunction with a variety of testing methods to troubleshoot intermittent electrical problems or as part of a regular maintenance plan.</p>
<h3>Kyoritsu 4105A-H Earth Tester Features:</h3>
<p>• Dust and drip proof.(designed to IEC 60529 IP54)<br />
• In addition to the facility for precision measurement, test leads for simplified two wire easuring system also supplied as standard accessories.<br />
(unit can be hung from the neck for simplified measurement)<br />
• Designed to meet IEC 61010-1 safety standard.<br />
• Capable of measuring earth voltage.<br />
• Automatic warning when resistance of auxiliary earth spikes is in excess of tolerance.<br />
• Small and lightweight. Shock resistant new case material.<br />
• 2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test.</p>
<p><a href="http://rapid-tech.com.au/wp-content/uploads/2017/08/Kyoritsu-4105a-Hardcase.jpg"><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-5449" src="http://rapid-tech.com.au/wp-content/uploads/2017/08/Kyoritsu-4105a-Hardcase-300x183.jpg" alt="Kyoritsu 4105a Hardcase" width="300" height="183" srcset="https://rapid-tech.com.au/wp-content/uploads/2017/08/Kyoritsu-4105a-Hardcase-300x183.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2017/08/Kyoritsu-4105a-Hardcase.jpg 350w" sizes="auto, (max-width: 300px) 100vw, 300px" /></a></p>
<h3>Kyoritsu 4105A-H Earth Tester Specifications:</h3>
<table class="specTable mb0">
<tbody>
<tr>
<th>Measurement ranges</th>
<td>Earth Resistance: 0 &#8211; 20Ω/0 &#8211; 200Ω/0 &#8211; 2000Ω<br />
Earth Voltage [50,60Hz]: 0 &#8211; 200V AC</td>
</tr>
<tr>
<th>Accuracy</th>
<td>Earth Resistance: ±2%rdg±0.1Ω (20Ωrange)<br />
±2%rdg±3dgt (200Ω/2000Ωrange)<br />
Earth Voltage: ±1%rdg±4dgt</td>
</tr>
<tr>
<th>Overload protection</th>
<td>Earth Resistance: 280V AC for 10 seconds<br />
across 2 of the 3 terminals<br />
Earth Voltage: 300V AC for 1 minute</td>
</tr>
<tr>
<th>Applicable standards</th>
<td>IEC 60529 IP54</td>
</tr>
<tr>
<th>Safety Standard</th>
<td>IEC 61010-1 CAT III 300V Pollution Degree 2, IEC 61557</td>
</tr>
<tr>
<th>Power source</th>
<td>R6 (AA) (1.5V) × 6</td>
</tr>
<tr>
<th>Dimensions</th>
<td>105(L) × 158(W) × 70(D)mm</td>
</tr>
<tr>
<th>Weight</th>
<td>550g approx.</td>
</tr>
<tr>
<th>Included Accessories</th>
<td>7095A (Earth resistance test leads) × 1set<br />
(red-20m, yellow-10m, green-5m)<br />
8032 (Auxiliary earth spikes) × 1set<br />
7127A (Simplified measurement probe) × 1set<br />
R6 (AA) × 6<br />
9121 (Shoulder strap)<br />
Instruction Manual<br />
Carrying case :  9165 (Hard Carrying case )</td>
</tr>
<tr>
<th>Optional Accessories</th>
<td>7100A (Precision measurement cord set)</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-4105a-h-earth-tester-hard-case-model/">Kyoritsu 4105A-H Earth Tester &#8211; Hard Case Model</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Kyoritsu 4102A-H Earth Tester &#8211; Hard Case Model</title>
		<link>https://rapid-tech.com.au/kyoritsu-4102a-h-earth-tester-hard-case-model/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Wed, 30 Aug 2017 05:51:46 +0000</pubDate>
				<guid isPermaLink="false">http://rapid-tech.com.au/?post_type=product&#038;p=5436</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-Authorised.jpg"><img class="alignnone size-full wp-image-7630" src="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-Authorised.jpg" alt="" width="250" height="69" /></a></p>
<p>The Kyoritsu 4102A-H tester performs three-pole earth resistance and two-pole voltage testing of electrical equipment and systems wiring and grounding to reduce power quality issues and avoid safety hazards. The meter is small and lightweight, with shock-resistant case material and taut-band movement. The OK light verifies proper connection between auxiliary earth resistance and lead wire connection to terminals. The tester warns the user when the resistance of auxiliary earth spikes exceeds tolerance. Ground-resistance meters are used by electricians and contractors working in industrial, utility, and field servicing.</p>
<h4>Kyoritsu 4102A-H Earth Tester Features:</h4>
<p>• The latest circuit design permits the instrument to operate<br />
with the minimum of influence from earth voltage<br />
and earth resistance of auxiliary earth spikes.<br />
• Dust and drip proof. (designed to IEC 529 IP54)<br />
• Earth resistance value can be read directly from the scale.<br />
• Designed to meet IEC 61010-1 safety standard.<br />
• Capable of measuring earth voltage.<br />
• Small and lightweight. Shock resistant new case material.<br />
• 2mA measuring current permits earth resistance tests<br />
without tripping earth leakage current breakers<br />
in the circuit under test.<br />
• Lead wire connection to C and P terminals and proper<br />
auxiliary earth resistance can be checked by "OK" lamp.<br />
Lead wire connection to C and E terminals is good<br />
when "OK" lamp is illuminated.<br />
• Hard Carry Case</p>
<h3><img class="alignnone size-full wp-image-5149" src="http://rapid-tech.com.au/wp-content/uploads/2017/05/pdf_sml-1.png" alt="pdf_sml" width="40" height="40" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2017/08/Kyoritsu-4102A_4105A-Datasheet.pdf" rel="noopener">Kyoritsu 4102A_4105A Datasheet</a></span></span></h3>
<h3><a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2017/05/pdf_sml-1.png" rel="noopener"><img class="alignnone size-full wp-image-5149" src="http://rapid-tech.com.au/wp-content/uploads/2017/05/pdf_sml-1.png" alt="pdf_sml" width="40" height="40" /></a>    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2017/08/Kyoritsu-4102A-User-Manual.pdf" rel="noopener">Kyoritsu 4102A User Manual</a></span></span></h3>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-4102a-h-earth-tester-hard-case-model/">Kyoritsu 4102A-H Earth Tester &#8211; Hard Case Model</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Kyoritsu 4102A Earth Tester is capable of testing earth resistance up to 1200Ω. This can be achieved via the 2 pole or 3 pole method with the supplied accessories.</p>
<p>The Kyoritsu 4102A Earth Tester is designed so that the influence of the earth voltage and earth resistance of the auxiliary spikes are neglected under the earth resistance test. A low measuring current of 2mA allows earth resistance tests to be performed without tripping earth leakage current breakers. The Kyoritsu 4102A Earth Tester also has the ability to measure earth voltage, up to 30V AC.</p>
<p>Small and lightweight, the Kyoritsu 4102A Earth Tester is both dust and drip proof, conforming to the IP54 standard. The instrument is also shock resistant and designed to meet IEC 61010-1 safety standard. The Kyoritsu 4102A-H Earth Tester is supplied with earth resistance test leads, measurement probe, auxiliary spike kit, batteries, a shoulder strap and a hard carry case.</p>
<h3>Kyoritsu 4102A-H Earth Tester Specifications:</h3>
<table class="specTable mb0" style="height: 577px;" width="729">
<tbody>
<tr>
<th>Measurement ranges</th>
<td>Earth Resistance: 0 &#8211; 12 Ω/0 &#8211; 120 Ω/0 &#8211; 1200 Ω<br />
Earth Voltage [50,60Hz]: 0 &#8211; 30V AC</td>
</tr>
<tr>
<th>Accuracy</th>
<td>Earth Resistance: ±3% of full scale<br />
Earth Voltage: ±3% of full scale</td>
</tr>
<tr>
<th>Overload protection</th>
<td>Earth Resistance: 276V AC for 10 seconds<br />
across 2 of the 3 terminals<br />
Earth Voltage: 276V AC for 1 minute</td>
</tr>
<tr>
<th>Applicable standards</th>
<td>IEC 61010-1 CAT III 300V Pollution Degree 2, IEC 61557<br />
IEC 60529 IP54</td>
</tr>
<tr>
<th>Power source</th>
<td>R6 (AA) (1.5V) × 6</td>
</tr>
<tr>
<th>Dimensions</th>
<td>105(L) × 158(W) × 70(D)mm</td>
</tr>
<tr>
<th>Weight</th>
<td>600g approx.</td>
</tr>
<tr>
<th>Included Accessories</th>
<td>7095A (Earth resistance test leads) × 1set<br />
(red-20m, yellow-10m, green-5m)<br />
8032 (Auxiliary earth spikes) × 1set<br />
7127A (Simplified measurement probe) × 1set<br />
R6 (AA) × 6<br />
9121 (Shoulder strap)<br />
Instruction Manual<br />
Carrying case : : 9164 (Carrying case[Hard])</td>
</tr>
<tr>
<th>Optional Accessories</th>
<td>7100A (Precision measurement cord set)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/kyoritsu-4102a-h-earth-tester-hard-case-model/">Kyoritsu 4102A-H Earth Tester &#8211; Hard Case Model</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
