<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Earth Tester Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/earth-tester/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/earth-tester/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Mon, 17 Aug 2026 00:12:51 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.10</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>Earth Tester Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/earth-tester/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Hioki CM4002 AC Leakage Clamp Meter — Find Nuisance RCD Trips Down to 0.001 mA</title>
		<link>https://rapid-tech.com.au/hioki-cm4002-ac-leakage-clamp-meter-find-nuisance-rcd-trips-down-to-0-001-ma/</link>
					<comments>https://rapid-tech.com.au/hioki-cm4002-ac-leakage-clamp-meter-find-nuisance-rcd-trips-down-to-0-001-ma/#respond</comments>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Sun, 16 Aug 2026 23:35:55 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=1121994</guid>

					<description><![CDATA[<p><img class="alignnone wp-image-7409" src="https://mymeter.com.au/wp-content/uploads/2022/03/logo-01-300x56-1.png" alt="Hioki logo" width="182" height="34" /></p>
<p><a target="_blank" href="https://mymeter.com.au/product/hioki-cm4002-ac-leakage-clamp-meter-find-nuisance-rcd-trips-down-to-0-001-ma" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<div id="" data-jasper-canvas="[{">
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="7:1-7:442;136-577">Chasing a safety switch that trips at 3am? The Hioki CM4002 AC Leakage Clamp Meter resolves earth leakage faults from 0.060 mA right through to 200 A load current, without pulling a single conductor out of the board. A Ø40 mm jaw swallows a full three-phase-plus-neutral bundle, a 180 Hz filter strips out inverter noise, and IEC/EN 61557-13 Class 2 compliance backs every reading. CAT IV 300 V / CAT III 600 V. Ready to test out of the box.</p>
<p dir="ltr" data-sourcepos="7:1-7:442;136-577"><img class="alignnone size-full wp-image-19857" src="https://rapid-tech.com.au/wp-content/uploads/2021/09/3-year-warranty.png" alt="3 year warranty" width="180" height="64" /></p>
</div>
<h4 class="ai-optimize-53"><img class="alignnone size-full wp-image-6653" src="https://mymeter.com.au/wp-content/uploads/2018/10/PDF-blue.png" alt="PDF download" width="43" height="54" /> <a target="_blank" href="https://www.hioki.com/global/download/37482" rel="noopener">Clampmeters Brochure</a></h4>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/hioki-cm4002-ac-leakage-clamp-meter-find-nuisance-rcd-trips-down-to-0-001-ma/">Hioki CM4002 AC Leakage Clamp Meter — Find Nuisance RCD Trips Down to 0.001 mA</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3 class="mt-2 -mb-1 text-base font-bold" dir="ltr" data-sourcepos="13:1-13:61;621-681">The fault that never happens while you&#8217;re standing there</h3>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="15:1-15:259;683-941">Every sparky knows the job. The safety switch on the shop&#8217;s power circuit drops out twice a week, always after hours, never when you&#8217;re on site. You reset it, test it with an RCD tester, everything passes, and you leave. Two days later the phone rings again.</p>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="17:1-17:308;943-1250">Intermittent earth leakage is one of the most expensive faults in Australian electrical work, because the cost isn&#8217;t in the repair — it&#8217;s in the return visits, the lost stock in a cold room, the production line that stopped, and the customer who starts to wonder whether you actually know what you&#8217;re doing.</p>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="19:1-19:534;1252-1785">The reason it&#8217;s so hard to pin down is simple physics. Under AS/NZS 3000, RCD protection is now standard across most final subcircuits, and a 30 mA device is permitted to operate anywhere between 50% and 100% of its rated residual current. That means a board sitting at 18 mA of standing leakage isn&#8217;t faulty — it&#8217;s just one kettle, one damp motor winding, or one extra inverter away from tripping. A pass/fail RCD tester will never show you that. You need to see the actual number, and you need to see it while the plant is running.</p>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="21:1-21:82;1787-1868">That&#8217;s exactly the job the <strong>Hioki CM4002 AC Leakage Clamp Meter</strong> was built for.</p>
<h3 class="mt-2 -mb-1 text-base font-bold" dir="ltr" data-sourcepos="23:1-23:34;1870-1903">What the CM4002 actually does</h3>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="25:1-25:532;1905-2436">The CM4002 is a dedicated true-RMS earth leakage clamp meter. Instead of measuring current in one conductor, you clamp <em>all</em> the live conductors of a circuit together — active and neutral on a single-phase final subcircuit, or all three phases plus neutral on a 415 V feeder. Under healthy conditions those currents cancel, and the meter reads close to zero. Whatever&#8217;s left over is the vector sum: current that has found a path back to earth. That&#8217;s the zero-phase current, and it&#8217;s the same quantity the RCD upstream is watching.</p>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="27:1-27:405;2438-2842">Six ranges span 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A and 200.0 A, with a defined accuracy range from 0.060 mA to 200.0 A. The bottom range resolves to 0.001 mA. That span matters more than it looks: the same instrument that resolves a microamp-level insulation problem in a control cabinet can also read the 80 A load current on the feeder beside it, so you&#8217;re not swapping tools mid-diagnosis.</p>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="29:1-29:169;2844-3012">Basic accuracy is ±1.0% rdg ±5 dgt from 45 Hz to 400 Hz across the 6.000 mA to 6.000 A ranges — comfortably inside the band where a 50 Hz Australian installation lives.</p>
<h3 class="mt-2 -mb-1 text-base font-bold" dir="ltr" data-sourcepos="31:1-31:55;3014-3068">Readings you can defend, backed by IEC/EN 61557-13</h3>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="33:1-33:117;3070-3186">Any clamp will show you a number. The question is whether that number survives scrutiny when you put it in a report.</p>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="35:1-35:387;3188-3574">Hioki designed the CM4002&#8217;s current transformer specifically to answer that. The core and shielding are built from high-permeability magnetic materials and the CT is wound with a uniform coil, and the instrument complies with <strong>IEC/EN 61557-13 Class 2, 30 A/m</strong> — the international performance standard written specifically for leakage clamp meters. Three practical consequences follow:</p>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="37:1-37:263;3576-3838"><strong>Position inside the jaw stops mattering.</strong> Sensitivity is uniform across the aperture, so a fat two-core bundle jammed against one side of the jaw reads the same as one perfectly centred. In a densely wired distribution board, &#8220;perfectly centred&#8221; is a fantasy.</p>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="39:1-39:321;3840-4160"><strong>Neighbouring busbars stop lying to you.</strong> Shielding blocks external magnetic fields, with the effect of a 400 A/m external field at 50/60 Hz specified at 4 mA or less. When you&#8217;re clamping a 15 mA leakage path 50 mm away from a loaded 415 V busbar, that specification is the difference between a diagnosis and a guess.</p>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="41:1-41:656;4162-4817"><strong>Inverter noise can be filtered out.</strong> A switchable low-pass filter with a −3 dB point at 180 Hz ±30 Hz strips high-frequency capacitive leakage from variable speed drives, solar inverters and switch-mode supplies. This is the feature that quietly earns its keep on modern sites. The EMC filters inside a VSD or a PV inverter dump genuine — but harmless — high-frequency current to earth. An unfiltered clamp adds all of it to the reading and sends you hunting a fault that doesn&#8217;t exist. With the filter on, the CM4002 sees the installation roughly the way a Type AC or Type A RCD sees it: at power frequency, where tripping decisions are actually made.</p>
<h3 class="mt-2 -mb-1 text-base font-bold" dir="ltr" data-sourcepos="43:1-43:44;4819-4862">Ø40 mm jaw, built for real switchboards</h3>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="45:1-45:412;4864-5275">The jaw opens to a Ø40 mm conductor diameter with jaw dimensions of 75 mm × 20 mm. That&#8217;s enough to take a three-phase-plus-neutral bundle on a submain, a large single cable, or several smaller circuits at once when you&#8217;re bisecting an installation to isolate the offending branch. Undersized jaws are the most common reason a leakage clamp ends up unused in the back of a ute — this one goes where the work is.</p>
<h3 class="mt-2 -mb-1 text-base font-bold" dir="ltr" data-sourcepos="47:1-47:48;5277-5324">Catching the fault that only happens at 3am</h3>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="49:1-49:70;5326-5395">This is where the CM4002 separates itself from a basic leakage clamp.</p>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="51:1-51:170;5397-5566">Fit the optional <strong>Z3210 Wireless Adapter</strong> and the meter gains Bluetooth®, connecting to Hioki&#8217;s free <strong>GENNECT Cross</strong> app on a phone or tablet. Two workflows open up:</p>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="53:1-53:564;5568-6131"><strong>Event recording.</strong> Set a leakage threshold and a recording window, clamp the meter onto the suspect circuit, and walk away. The instrument logs trip start times, trip stop times and maximum current values to internal memory — up to 999 events, over a recording period of up to 30 days (battery life permitting). You don&#8217;t need to stay connected to the tablet while it records. Come back, pull the data into GENNECT Cross, and you have a timestamped picture of an intermittent fault that no amount of standing in front of a switchboard would ever have given you.</p>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="55:1-55:382;6133-6514"><strong>Photo drawing for routine inspections.</strong> Photograph the board, then tap measurement locations on the image and drop the live readings onto the photo. Work upstream to downstream, and the fault location builds itself visually as you go. You can export a PDF report on site, before you&#8217;ve left the customer&#8217;s car park — which does more for repeat work than any amount of marketing.</p>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="57:1-57:247;6516-6762">With the Z3210 fitted, GENNECT Cross will also display current harmonics up to the 30th order, along with content factor and total harmonic distortion — useful context when leakage and power quality problems are tangled together on the same site.</p>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="59:1-59:380;6764-7143">Prefer to leave the phone in your pocket? The <strong>Excel® Direct Input</strong> function types measured values straight into a spreadsheet on a connected device each time auto-hold captures a reading. For calibration technicians and facilities teams doing scheduled runs across dozens of circuits, that&#8217;s an entire transcription step — and an entire class of transcription error — deleted.</p>
<h3 class="mt-2 -mb-1 text-base font-bold" dir="ltr" data-sourcepos="61:1-61:42;7145-7186">The details that matter on a long day</h3>
<ul class="[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1" dir="ltr" data-sourcepos="63:1-69:72;7188-8076">
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="63:1-63:152;7188-7339"><strong>Dual readout</strong> shows current and frequency simultaneously, so you can spot straight away when a reading is dominated by something other than 50 Hz.</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="64:1-64:142;7340-7481"><strong>Auto hold</strong> waits for the value to stabilise, then locks it — for when the meter is at arm&#8217;s length inside a board and the display isn&#8217;t.</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="65:1-65:120;7482-7601"><strong>Comparator</strong> gives audible and visual pass/fail against a threshold you set. Eyes stay on the work, not the screen.</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="66:1-66:123;7602-7724"><strong>Max / Min / AVG / PEAK MAX / PEAK MIN</strong> capture, plus <strong>inrush current</strong> measurement for motor and transformer starts.</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="67:1-67:166;7725-7890"><strong>48 hours</strong> of continuous running on two AA alkalines (about 30 hours with the Z3210 fitted and communicating). Batteries you can buy at any servo in the country.</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="68:1-68:114;7891-8004"><strong>−10°C to 65°C</strong> operating range — a roof cavity in a Mildura February, or a cool store in a Tasmanian winter.</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="69:1-69:72;8005-8076"><strong>400 g</strong> and 233 mm long, with the <strong>C0203 carrying case included</strong>.</li>
</ul>
<h3 class="mt-2 -mb-1 text-base font-bold" dir="ltr" data-sourcepos="71:1-71:41;8078-8118">Where it earns its keep in Australia</h3>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="73:1-73:240;8120-8359"><strong>Electrical contractors</strong> tracing nuisance safety switch trips in retail, hospitality and residential switchboards — measuring standing leakage before it becomes a callback, and quantifying how close a board is running to its 30 mA limit.</p>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="75:1-75:185;8361-8545"><strong>Industrial maintenance teams</strong> on VSD-heavy plant, where the filter function separates genuine insulation degradation from the capacitive leakage that drives are supposed to produce.</p>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="77:1-77:308;8547-8854"><strong>Solar installers</strong> verifying leakage behaviour on grid-connected PV systems, where inverter EMC filters, long DC runs and damp roof penetrations all contribute earth current — and where the difference between a real AS/NZS 5033 insulation problem and normal system leakage needs to be established quickly.</p>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="79:1-79:351;8856-9206"><strong>Facility managers and safety officers</strong> building a documented leakage baseline across a site, so that next year&#8217;s figures mean something. Earth leakage current measurement is also used in in-service testing work under AS/NZS 3760 alongside insulation resistance testing, particularly on equipment where a standard insulation test isn&#8217;t appropriate.</p>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="81:1-81:235;9208-9442"><strong>TAFEs, RTOs and engineering departments</strong> teaching residual current theory with an instrument that demonstrates the concept properly — including <em>why</em> jaw position and external fields matter, using a meter engineered to defeat both.</p>
<h3 class="mt-2 -mb-1 text-base font-bold" dir="ltr" data-sourcepos="83:1-83:51;9444-9494">Choosing between the CM4002, CM4003 and CM4001</h3>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="85:1-85:156;9496-9651">The CM4002 and CM4003 share the same sensor, the same six ranges and the same IEC/EN 61557-13 Class 2 compliance. The differences are about where you work:</p>
<ul class="[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1" dir="ltr" data-sourcepos="87:1-89:83;9653-10208">
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="87:1-87:243;9653-9895"><strong>CM4002</strong> carries the higher safety rating — <strong>CAT IV 300 V and CAT III 600 V</strong> conductor-to-ground. If you work at the origin of an installation, at the main switchboard, or on service and metering equipment, this is the model to specify.</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="88:1-88:230;9896-10125"><strong>CM4003</strong> trades safety category down to CAT III 300 V but adds an analogue output (RMS and waveform) for feeding a recorder or Memory HiCorder, plus external DC power for unattended recording that outlasts a set of batteries.</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="89:1-89:83;10126-10208"><strong>CM4001</strong> is the entry point in the family, with a lower event memory capacity.</li>
</ul>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="91:1-91:386;10210-10595">For general field work in Australian installations — where a 415 V three-phase system sits at roughly 240 V phase-to-earth, and where you&#8217;re regularly working upstream of the main switch — the CM4002&#8217;s CAT IV 300 V rating is the sensible default. As always, confirm the measurement category against your own risk assessment and the specific point of the installation you&#8217;re working on.</p>
<p dir="ltr" data-sourcepos="91:1-91:386;10210-10595"><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-1122194" src="https://mymeter.com.au/wp-content/uploads/2026/08/imgi_2_img_cont_10.webp" alt="Hioki CM4001, Hioki CM4002 and Hioki CM4003" width="1178" height="1041" /></p>
<h3 class="mt-2 -mb-1 text-base font-bold" dir="ltr" data-sourcepos="93:1-93:33;10597-10629">Ready to test out of the box</h3>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="95:1-95:275;10631-10905">Every CM4002 ships with the C0203 carrying case, instruction manual, operating precautions and two AA alkaline batteries. Order the <strong>CM4002-90</strong> if you want the Z3210 Wireless Adapter bundled from day one — for anyone doing intermittent fault work, it&#8217;s the version to get.</p>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="97:1-97:402;10907-11308">We&#8217;re a specialist test and measurement supplier, not a general tool shop. That means we can talk you through whether the CM4002 or the CM4003 fits your work, sort out calibration and recertification when it&#8217;s due, and keep you supplied with the accessories that actually get used. Got a leakage problem you can&#8217;t pin down? Talk to us before you order — we&#8217;d rather sell you the right instrument once.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h2 class="mt-3 -mb-1 text-[1.125rem] font-bold" dir="ltr" data-sourcepos="101:1-101:31;11315-11345">Technical Specifications</h2>
<div class="overflow-x-auto w-full pl-[var(--msg-block-inset,0.5rem)] pr-2 mb-6 print:overflow-x-visible" dir="ltr" data-sourcepos="103:1-136:135;11347-15418">
<table class="min-w-full border-collapse text-sm leading-[1.7] whitespace-normal">
<thead class="text-left">
<tr>
<th class="text-text-100 border-b-0.5 border-[hsl(var(--border-300)/0.6)] py-2 pr-4 align-top font-bold" scope="col">Specification</th>
<th class="text-text-100 border-b-0.5 border-[hsl(var(--border-300)/0.6)] py-2 pr-4 align-top font-bold" scope="col">Value</th>
<th class="text-text-100 border-b-0.5 border-[hsl(var(--border-300)/0.6)] py-2 pr-4 align-top font-bold" scope="col">Why It Matters</th>
</tr>
</thead>
<tbody>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Measurement type</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">AC current only, true RMS</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Reads distorted real-world waveforms accurately — no averaging error on non-linear loads</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">AC current ranges</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">6.000 mA / 60.00 mA / 600.0 mA / 6.000 A / 60.00 A / 200.0 A (6 ranges)</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">One instrument covers microamp leakage through to feeder load current</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Defined accuracy range</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">0.060 mA to 200.0 A</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Specified performance across the whole span, not just mid-scale</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Best resolution</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">0.001 mA</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Resolves leakage changes long before an RCD reacts</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Basic accuracy (45 Hz–400 Hz)</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">±1.0% rdg ±5 dgt (6.000 mA to 6.000 A); ±1.5% rdg ±5 dgt (60.00 A, 200.0 A)</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Defensible figures at 50 Hz for compliance reporting</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Accuracy (15–45 Hz, 400 Hz–2 kHz)</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">±2.0% rdg ±5 dgt</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Still specified outside power frequency for drive and harmonic work</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Frequency measurement</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">15.0 Hz to 2000 Hz</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Identify whether leakage is at 50 Hz or driven by switching noise</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Low-pass filter</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">−3 dB at 180 Hz ±30 Hz</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Strips inverter and VSD capacitive leakage so readings reflect what the RCD sees</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">External magnetic field immunity</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">≤4 mA error at 400 A/m, 50/60 Hz</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Reliable readings inside crowded switchboards near loaded busbars</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Standards compliance</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">IEC/EN 61557-13: Class 2, 30 A/m</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Performance verified against the international standard for leakage clamps</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Safety / EMC standards</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Safety: EN 61010 (type A current sensor); EMC: EN 61326</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Designed and tested to recognised international safety and EMC requirements</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Measurement category</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">CAT IV 300 V / CAT III 600 V (conductor-to-ground)</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Rated for work at the origin of installation and main switchboards</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Crest factor</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">3 (all ranges except 200.0 A); 1.5 on 200.0 A</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Handles peaky non-sinusoidal leakage without clipping</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Core jaw diameter</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Ø40 mm (1.57 in.)</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Takes a three-phase-plus-neutral bundle or a large single cable</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Jaw dimensions</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">75 mm × 20 mm</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Fits between adjacent circuits in a tightly packed board</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Display refresh rate</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">5 times per second</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Fast enough to see leakage move as loads switch</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Functions</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Max / Min / AVG / PEAK MAX / PEAK MIN, display hold and auto hold, backlight, auto power save, buzzer, event count display, comparator, simple event recording, inrush current measurement</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Covers diagnostic and routine inspection workflows without accessories</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Harmonics (with Z3210)</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Current harmonics to 30th order, content factor, THD via GENNECT Cross</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Links leakage investigation to power quality context</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Event recording (with Z3210)</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Up to 999 events; recording period up to 30 days (battery dependent)</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Captures intermittent faults unattended, over weeks</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Wireless</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Optional Z3210 Wireless Adapter (Bluetooth®)</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Data to phone/tablet, PDF reports on site, Excel® Direct Input</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Power supply</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">2 × AA alkaline (LR6)</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Replaceable anywhere, no proprietary pack</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Battery life</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Approx. 48 h; approx. 30 h with Z3210 communicating</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Multi-day jobs without a battery change</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Operating temperature</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">−10°C to 65°C</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Roof cavities, plant rooms and cool stores all covered</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Operating humidity</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">≤80% RH (−10 to 40°C); ≤60% RH (40–45°C); ≤50% RH (45–65°C), non-condensing</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Defined limits for hot, humid Australian conditions</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Storage temperature</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">−30°C to 70°C</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Survives a ute toolbox</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Ingress protection</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">IP40 (jaws closed)</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Dust-protected for indoor work; not rated for wet exposure</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Operating environment</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Indoors, pollution degree 2, altitude ≤2000 m</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Defines the intended use environment</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Dimensions</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">64 mm W × 233 mm H × 37 mm D</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Slim enough to work between cables in a board</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Weight</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">400 g</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Light enough for extended overhead work</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Accuracy guarantee</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">1 year</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Sets the recommended recalibration interval</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Included accessories</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Carrying case C0203, instruction manual, operating precautions, 2 × AA alkaline batteries</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Ready to test out of the box</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Model variants</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">CM4002 (meter only); CM4002-90 (with Z3210 Wireless Adapter)</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Choose standalone or wireless-enabled from day one</td>
</tr>
</tbody>
</table>
</div>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="138:1-138:176;15420-15595"><em>Specifications sourced from Hioki CM4002/CM4003 catalogue (rev. CM4002_CM4003E6-3ZE) and the Hioki global product page. Specifications subject to change by the manufacturer.</em></p>
<blockquote>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="144:1-145:543;15627-16208"><strong>What is the Hioki CM4002 used for?</strong> The Hioki CM4002 is an AC leakage clamp meter used to measure earth leakage current in electrical installations without disconnecting conductors. Electricians clamp it around all live conductors of a circuit at once — active and neutral, or three phases plus neutral — and the meter reads the residual current returning to earth. Its main applications are diagnosing nuisance RCD and safety switch trips, establishing standing leakage baselines during routine inspections, and locating insulation faults in industrial and solar installations.</p>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="147:1-148:599;16210-16882"><strong>How does the Hioki CM4002 find the cause of a tripping safety switch?</strong> It measures the actual leakage current the RCD is responding to, in milliamps, while the installation stays energised. Because an RCD may operate anywhere between 50% and 100% of its rated residual current, a 30 mA safety switch can trip on as little as 15 mA of accumulated leakage. By clamping progressively downstream through a switchboard, an electrician narrows the leakage to a single final subcircuit. With the optional Z3210 adapter fitted, the CM4002 can also log up to 999 trip events over as long as 30 days, capturing faults that only appear overnight or under specific load conditions.</p>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="150:1-151:259;16884-17203"><strong>What is the lowest current the Hioki CM4002 can measure?</strong> The CM4002 has a defined accuracy range starting at 0.060 mA, with a best resolution of 0.001 mA on the 6.000 mA range. Its full span extends to 200.0 A across six ranges, so it covers both micro-level leakage detection and ordinary load current measurement.</p>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="153:1-154:259;17205-17516"><strong>Is the Hioki CM4002 compliant with IEC 61557-13?</strong> Yes. The CM4002 complies with IEC/EN 61557-13 at Class 2, 30 A/m — the international performance standard specifically for leakage current clamp meters. The instrument is also designed to EN 61010 for safety (as a type A current sensor) and EN 61326 for EMC.</p>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="156:1-157:404;17518-17989"><strong>What is the difference between the Hioki CM4002 and the CM4003?</strong> Both share the same sensor, six ranges and IEC/EN 61557-13 Class 2 compliance. The CM4002 has the higher safety rating at CAT IV 300 V / CAT III 600 V, making it the choice for work at the origin of an installation or on main switchboards. The CM4003 is rated CAT III 300 V but adds an analogue output for RMS and waveform recording, plus an external DC power input for long-duration unattended logging.</p>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="159:1-160:425;17991-18488"><strong>Can the Hioki CM4002 measure leakage on solar and VSD installations?</strong> Yes, and it includes a specific feature for it. Variable speed drives and PV inverters produce high-frequency capacitive leakage through their EMC filters, which inflates readings on an unfiltered clamp meter. The CM4002&#8217;s switchable low-pass filter (−3 dB at 180 Hz ±30 Hz) removes that high-frequency component, so the displayed value reflects the power-frequency leakage that a Type AC or Type A RCD actually responds to.</p>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="162:1-163:415;18490-18960"><strong>Does the Hioki CM4002 connect to a phone or tablet?</strong> Not on its own. Adding the optional Z3210 Wireless Adapter gives the meter Bluetooth® connectivity to Hioki&#8217;s free GENNECT Cross app for iOS and Android. From there you can view live readings, log events, display current harmonics to the 30th order, place readings onto site photographs, generate PDF reports on site, and push values directly into an Excel® file. The CM4002-90 model ships with the Z3210 included.</p>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="165:1-166:248;18962-19252"><strong>Does the Hioki CM4002 measure voltage?</strong> No. The CM4002 is a dedicated AC leakage current instrument and does not include a voltage measurement function. Electricians typically carry it alongside a multimeter or a multifunction installation tester rather than as a replacement for either.</p>
<p class="font-claude-response-body break-words whitespace-normal" dir="ltr" data-sourcepos="168:1-169:278;19254-19589"><strong>What size cable does the Hioki CM4002 jaw fit around?</strong> The jaws accept conductors up to Ø40 mm in diameter, with internal jaw dimensions of 75 mm × 20 mm. That&#8217;s large enough for a three-phase-plus-neutral bundle on a submain, a single large cable, or several smaller circuits clamped together when isolating a fault by elimination.</p>
</blockquote>
<p>The post <a href="https://rapid-tech.com.au/hioki-cm4002-ac-leakage-clamp-meter-find-nuisance-rcd-trips-down-to-0-001-ma/">Hioki CM4002 AC Leakage Clamp Meter — Find Nuisance RCD Trips Down to 0.001 mA</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/hioki-cm4002-ac-leakage-clamp-meter-find-nuisance-rcd-trips-down-to-0-001-ma/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HIOKI FT6041 Earth Tester &#124; Ground Resistance Meter &#124; Buy Australia</title>
		<link>https://rapid-tech.com.au/hioki-ft6041-earth-tester-ground-resistance-meter-buy-australia/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Sun, 15 Mar 2026 22:56:34 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=1119169</guid>

					<description><![CDATA[<p><img class=" wp-image-19115 alignnone" src="https://rapid-tech.com.au/wp-content/uploads/2021/08/logo-01-300x56.png" alt="Hioki logo" width="204" height="38" /></p>
<p><a target="_blank" href="https://mymeter.com.au/product/hioki-ft6041-91-earth-tester-set" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Getting accurate earth resistance readings on a live site — without shutting down power, wrestling with tangled cords, or worrying about mud and rain destroying your gear — used to mean compromises. The HIOKI FT6041 Earth Tester eliminates all of them. With six measurement methods in one rugged IP67-rated instrument, it handles everything from standard 3-pole testing to soil resistivity surveys and clamp-on live-wire measurement. Ready for Australian worksites. Ready for whatever the day throws at it.</p>
<p><img class="alignnone size-full wp-image-19222" src="https://rapid-tech.com.au/wp-content/uploads/2021/08/3-year-warranty.png" alt="3 year warranty" width="180" height="64" /></p>
<p><img class="alignnone size-full wp-image-19718" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" /> <a target="_blank" href="https://www.hioki.com/us-en/download/41241" rel="noopener">EARTH TESTER Series</a></p>
<p>The post <a href="https://rapid-tech.com.au/hioki-ft6041-earth-tester-ground-resistance-meter-buy-australia/">HIOKI FT6041 Earth Tester | Ground Resistance Meter | Buy Australia</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 class="text-text-100 mt-2 -mb-1 text-base font-bold">HIOKI FT6041 Earth Tester — Field-Ready Ground Resistance Testing for Any Site, Any Condition</h2>
<p>The Problem With Most Earth Resistance Testing on Australian Sites</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Ask any sparkie who&#8217;s spent time doing earthing compliance work what frustrates them most and you&#8217;ll hear the same answers: cords that tangle the moment you unwind them, dry soil that means you&#8217;re hammering auxiliary rods in again and again just to get a usable reading, and the awkward conversation with a site manager about shutting down power to a server room or hospital wing — just so you can run a standard 3-pole test.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Then there&#8217;s the paperwork. Carrying a notebook in the field, scribbling down values, trying to reconstruct a compliant test record later from memory and mud-smeared handwriting. It&#8217;s slow, error-prone, and honestly unnecessary with modern equipment.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Earthing system verification is a non-negotiable part of Australian electrical compliance work. Under AS/NZS 3000 (the Wiring Rules), electrical installations must have effective earthing to protect people from electric shock and equipment from fault damage. Soil resistivity surveys are required before grounding system design on commercial and industrial builds. Periodic testing of existing installations is required for ongoing compliance, particularly in facilities covered by AS/NZS 3017. The stakes are real — and your test instrument needs to be up to the job every single time.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The HIOKI FT6041 Earth Tester was engineered to address every one of these pain points directly.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Six Measurement Methods. One Instrument.</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Most earth testers on the market do the basics — 3-pole testing, maybe a 2-pole continuity check. The FT6041 goes considerably further, covering the full range of measurement scenarios encountered in real Australian electrical work:</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>3-Pole Method</strong> — The standard fall-of-potential method for precisely measuring ground resistance. Delivers results in just 6 seconds, with accuracy of ±1.5% rdg. ±4 dgt. across the core measurement range. Suitable for general electrical installation testing and compliance verification.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>4-Pole Method (Wenner&#8217;s Method)</strong> — Essential for soil resistivity measurement prior to grounding system design on new construction projects. Geological conditions vary dramatically across Australian regions — sandy coastal soils behave very differently to dense clay or rock formations inland. Getting this right upfront saves time, money, and compliance headaches later.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>MEC (Measuring Earth with a Clamp)</strong> — HIOKI&#8217;s standout capability. The MEC function — Measuring Earth with a Clamp — augments the 3-pole method with a clamp sensor to measure only the current flowing through the specific electrode under test. The result: you can measure earth resistance on live systems without disconnecting a single wire and without shutting down power. For data centres, hospitals, manufacturing facilities, and any other site where power interruption isn&#8217;t an option, this is a genuine game-changer.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>3-Pole Method with 4-Terminal Measurement</strong> — When you&#8217;re dealing with very low resistance ground systems — sub-ohm values on bonded structural steel or reinforced concrete installations — this method delivers the precision required.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>2-Clamp Method</strong> — For multi-point earthing systems where multiple parallel grounds are installed, the 2-clamp method lets you test individual earth electrodes in a network without disconnecting them from the system.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Low-Resistance Measurement</strong> — A built-in continuity check function using 4-terminal or 2-terminal measurement, covering ranges from 0.00 Ω to 3000 Ω. Ideal for confirming continuity of bonding conductors immediately after completing ground resistance testing — keeping your workflow tight.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Built to Survive Australian Jobsites</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Anyone who&#8217;s used an entry-level earth tester in the field knows the anxiety of a $400 instrument sitting in the dirt on a wet construction site or getting covered in red dust on a regional job. The FT6041 is built like it expects to be treated badly.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>IP67 Rated for Dust and Water</strong> — Completely sealed against dust ingress and protected against immersion in water to 1 metre depth. Mud splatter, rain, puddles — wash it off with water when you&#8217;re done. The EN60529-certified IP67 rating covers both the main unit and its sealed connectors.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>-25°C to +65°C Operating Range</strong> — Australian conditions are extreme in both directions. Whether you&#8217;re working through a Queensland summer on an exposed substation site or doing winter commissioning work in alpine Victoria, the FT6041 keeps operating without complaint across its full temperature range.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>1-Metre Drop Resistance</strong> — With the protector fitted, the FT6041 withstands a 1-metre drop onto concrete. This isn&#8217;t a marketing claim — it&#8217;s tested to the standard. For an instrument regularly carried up ladders, across scaffolding, and in and out of site vehicles, this matters.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>30 V RMS Ground Potential Tolerance</strong> — In environments where stray ground potentials are present — near power distribution infrastructure, industrial plant, or high-voltage installations — the FT6041 continues to deliver stable readings with an allowable ground potential of 30.0 V RMS. Live wire warning activates automatically when ground potential is detected.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Designed to Cut Time on Site</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Every minute saved on a measurement job is money back in your pocket. The FT6041 has been purpose-designed to eliminate the time-wasters.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Cord Winding That Actually Works</strong> — The measurement cables (included 25m yellow, 25m blue, and 50m red cables) are fitted with winders that retract cleanly without tangling or twisting. This sounds like a small thing until you&#8217;ve spent 10 minutes straightening knotted cables in a muddy paddock.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>100 kΩ Maximum Allowable Electrode Resistance</strong> — In dry or rocky Australian soils, getting good auxiliary electrode contact is a persistent challenge. The FT6041&#8217;s 100 kΩ maximum allowable resistance for auxiliary grounding electrodes means a single insertion is usually sufficient — no repeated pouring of water around the rods, no repeat insertions trying to hit a usable resistance value.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Earth Nets Module for Concrete Surfaces</strong> — Not every measurement location has accessible soil. The included L9846 Earth Nets Module provides a flat-surface electrode alternative for hard-standing concrete areas. Open the module, make contact with the surface, add a splash of water, and take the reading. No drilling required.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>6-Second Measurement Time</strong> — Full 3-pole measurement in 6 seconds. Combined with auto-hold to capture the reading and continuous measurement mode for monitoring, the FT6041 keeps your workflow moving.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Wireless Data Capture and Reporting</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The FT6041 supports the optional HIOKI Z3210 Wireless Adapter (available separately or as part of the FT6041-90 and FT6041-92 KIT variants), enabling Bluetooth connectivity to iOS and Android devices.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Paired with the free <strong>GENNECT Cross</strong> app, the system allows you to:</p>
<ul class="[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3">
<li class="whitespace-normal break-words pl-2">Automatically capture readings when auto-hold activates — no manual transcription</li>
<li class="whitespace-normal break-words pl-2">Attach site photos and handwritten annotations to measurement records</li>
<li class="whitespace-normal break-words pl-2">Overlay measurement values directly on site photographs and drawings</li>
<li class="whitespace-normal break-words pl-2">Export completed reports to Excel for inclusion in compliance documentation packages</li>
</ul>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">For electrical contractors managing compliance documentation under Australian workplace health and safety requirements, this is a significant time-saver and substantially reduces the risk of transcription errors.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Available Model Variants</h3>
<div class="overflow-x-auto w-full px-2 mb-6">
<table class="min-w-full border-collapse text-sm leading-[1.7] whitespace-normal">
<thead class="text-left">
<tr>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">Model</th>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">Configuration</th>
</tr>
</thead>
<tbody>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>FT6041</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Standard unit with full accessory kit</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>FT6041-90</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Standard unit + Z3210 Wireless Adapter</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>FT6041-91</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Standard unit + clamp sensors FT9847 &amp; CT9848</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>FT6041-92 KIT</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Full kit: unit + wireless adapter + both clamp sensors</td>
</tr>
</tbody>
</table>
</div>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">For most Australian electrical contractors who need the MEC function for live-system testing, the <strong>FT6041-91</strong> or <strong>FT6041-92 KIT</strong> is the recommended configuration.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h2 class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold">TECHNICAL SPECIFICATIONS</h2>
<div class="overflow-x-auto w-full px-2 mb-6">
<table class="min-w-full border-collapse text-sm leading-[1.7] whitespace-normal">
<thead class="text-left">
<tr>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">Specification</th>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">Value</th>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">Why It Matters</th>
</tr>
</thead>
<tbody>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Measurement Methods</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">4-pole, 3-pole, 2-pole, MEC function, 2-clamp, low-resistance</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Covers every earthing test scenario from standard installation checks to soil surveys and live-system clamp measurement</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Ground Resistance Range</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">0 to 300.0 kΩ (6 ranges)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Wide measurement range handles everything from ultra-low resistance bonded structures to high-resistance earthing in poor soil</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>3-Pole Accuracy</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">±1.5% rdg. ±4 dgt. (30–300 Ω range)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Precision sufficient for compliance reporting under AS/NZS 3000 and AS/NZS 3017</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>MEC Function Range</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">0.00 Ω to 30.00 kΩ</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Allows live-system testing without power interruption — essential for hospitals, data centres, and 24/7 industrial facilities</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Allowable Ground Potential</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">30.0 V RMS</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Safe operation near power infrastructure where stray potentials are present</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Max. Auxiliary Electrode Resistance</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">100 kΩ (300–3000 Ω range)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Single-insertion electrode placement even in dry, rocky, or sandy Australian soils</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Measurement Time</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">6 seconds (3-pole method)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Fast enough to sustain efficient multi-point testing programs</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>IP Rating</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">IP67 (EN60529)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Full field protection — dust-tight and waterproof to 1 m depth</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Drop Resistance</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">1 m onto concrete (with protector)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Withstands typical site handling without instrument damage</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Operating Temperature</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">-25°C to +65°C</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Works through every Australian seasonal extreme</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Safety Category</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">CAT IV 100 V / CAT III 150 V / CAT II 300 V</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Appropriate safety ratings for field use in electrical installation environments</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Standards Compliance</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">EN61010, EN61326, EN61557-1/5/10/14</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Internationally certified to IEC safety and EMC standards</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Low-Resistance Measurement</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">0.00–3000 Ω (3 ranges), ±2% rdg.</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Bonding conductor continuity verification built in — no need for a separate instrument</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Power Supply</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">4× HR6 NiMH or 4× LR03 alkaline batteries</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Standard batteries, widely available on any Australian site</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Battery Life</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">500 measurements (3-pole, without Z3210)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Full working day from a single set of batteries in typical use</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Dimensions / Weight</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">189 × 148 × 48 mm / approx. 765 g (with battery &amp; protector)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Compact and portable — fits comfortably in a tool bag</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Included Cables</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">25m (×2), 50m, 4m measurement cables; 1.2m test lead</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Complete cable set for standard 3-pole testing from the box — no additional cable purchases required</td>
</tr>
</tbody>
</table>
</div>
<h2 class="font-claude-response-body break-words whitespace-normal leading-[1.7]"></h2>
<h2 class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold">WHY CHOOSE US FOR YOUR HIOKI FT6041</h2>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">We supply HIOKI test and measurement instruments with the same level of technical support you&#8217;d expect from a specialist calibration and compliance background — not a generic electronics reseller. When you order the FT6041 through us, you&#8217;re getting:</p>
<ul class="[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3">
<li class="whitespace-normal break-words pl-2"><strong>Genuine HIOKI product</strong> supplied through authorised Australian distribution channels</li>
<li class="whitespace-normal break-words pl-2"><strong>Pre-sales technical advice</strong> to ensure you select the right variant (FT6041, -90, -91, or -92 KIT) for your specific application</li>
<li class="whitespace-normal break-words pl-2"><strong>NATA-accredited calibration services</strong> available if your instrument requires a calibration certificate for compliance documentation</li>
<li class="whitespace-normal break-words pl-2"><strong>Fast Australian dispatch</strong> — no waiting on international freight for your core test instruments</li>
<li class="whitespace-normal break-words pl-2"><strong>Ongoing support</strong> from a team that understands Australian electrical compliance requirements, not just the product specs</li>
</ul>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Query:</strong> What is the HIOKI FT6041 used for?</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Answer:</strong> The HIOKI FT6041 is a professional earth resistance tester used for verifying the safety and compliance of grounding systems in electrical installations. It supports six measurement methods: standard 3-pole ground resistance testing, 4-pole soil resistivity measurement, MEC clamp-on live-system measurement (without disconnecting electrodes), 4-terminal low-value resistance measurement, 2-clamp multi-electrode testing, and low-resistance continuity checks. It is widely used by electrical contractors, facility maintenance teams, and commissioning engineers for compliance work under Australian electrical standards.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Query:</strong> Can you test earth resistance without disconnecting the ground wire?</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Answer:</strong> Yes. The HIOKI FT6041&#8217;s MEC (Measuring Earth with a Clamp) function allows earth resistance measurement on live systems without disconnecting any grounding electrodes. A clamp sensor detects only the current flowing through the specific electrode under test, isolating it from other parallel grounds. This capability is essential for testing in facilities such as hospitals, data centres, and industrial plants where power interruption is not possible. The optional FT9847 and CT9848 clamp sensors (included in FT6041-91 and FT6041-92 KIT) are required.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Query:</strong> What IP rating does the HIOKI FT6041 have?</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Answer:</strong> The HIOKI FT6041 Earth Tester carries an IP67 rating to EN60529. This means it is completely protected against dust ingress and can withstand immersion in water to 1 metre depth. It is also rated for operation across a temperature range of -25°C to +65°C and withstands a 1-metre drop onto concrete when the protector is attached — making it suitable for demanding outdoor and construction site use.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Query:</strong> What is the difference between the FT6041 and FT6041-91?</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Answer:</strong> The standard FT6041 includes the main instrument plus a full set of measurement cables, auxiliary earthing rods, the L9846 Earth Nets Module, carrying cases, and batteries. The FT6041-91 includes everything in the standard kit plus the FT9847 Signal Induction Clamp and CT9848 Clamp-On Sensor, which are required to use the MEC (live-system clamp) and 2-clamp measurement functions. The FT6041-92 KIT adds the Z3210 Wireless Adapter to the FT6041-91 configuration for Bluetooth data transfer.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Query:</strong> How do you measure soil resistivity with the HIOKI FT6041?</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Answer:</strong> The HIOKI FT6041 measures soil resistivity using Wenner&#8217;s 4-pole method. Four auxiliary electrodes are inserted into the ground at equal spacing, and the instrument injects a test current between the outer two electrodes while measuring the voltage across the inner two. The instrument calculates soil resistivity from these values. This measurement is used during the design phase of grounding systems to determine the electrode configuration required to achieve the target earth resistance, accounting for the specific geological conditions at the site.</p>
<p>The post <a href="https://rapid-tech.com.au/hioki-ft6041-earth-tester-ground-resistance-meter-buy-australia/">HIOKI FT6041 Earth Tester | Ground Resistance Meter | Buy Australia</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
