<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Earth and Ground Testers Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/earth-and-ground-testers/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/earth-and-ground-testers/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Thu, 27 Nov 2025 01:05:05 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.7</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>Earth and Ground Testers Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/earth-and-ground-testers/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>HT Italia HT2055 Step and contact meter up to 50A</title>
		<link>https://rapid-tech.com.au/ht-italia-ht2055-step-contact-meter-50a/</link>
					<comments>https://rapid-tech.com.au/ht-italia-ht2055-step-contact-meter-50a/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Fri, 13 May 2016 06:21:19 +0000</pubDate>
				<guid isPermaLink="false">http://rapid-tech.com.au/?post_type=product&#038;p=3389</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-974" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/HT-ITALIA-LOGO-1.png" alt="HT ITALIA LOGO" width="160" height="100" /></p>
<p>HT Italia HT2055 consists in a <strong>power unit</strong> and a <strong>voltmetric unit</strong>, necessary for carrying out step and contact voltage measurements in <strong>industrial electric installations typical of AT and AAT (TN systems, transformer cabinets) with a rated test current up to 50A.</strong></p>
<p>The two units, <strong>synchronized</strong> in time and current are capable of providing the correct value of step and contact voltages consistently with the real current values measured by the power unit, also taking into consideration the disturbance effects found on the measured circuit. It is also capable of measuring <strong>earth resistance and ground resistivity by the classical voltammetric method</strong>. These measurements can be saved in the <strong>internal memory</strong> of the voltmetric unit and downloaded onto the PC through the provided Windows software.</p>
<p><img class="alignnone size-full wp-image-3188" src="http://rapid-tech.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" />    <a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2016/05/HT2055-Cat.pdf" rel="noopener noreferrer">HT2055 Brochure</a></p>
<p><img class="alignnone size-full wp-image-3188" src="http://rapid-tech.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" />    <a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2016/05/HT2055-Datasheet.pdf" rel="noopener noreferrer">HT2055 Datasheet</a></p>
<p><img class="alignnone size-full wp-image-3188" src="http://rapid-tech.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" />    <a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2016/05/HT2055-User-Manual.pdf" rel="noopener noreferrer">HT2055 User Manual</a></p>
<p>The post <a href="https://rapid-tech.com.au/ht-italia-ht2055-step-contact-meter-50a/">HT Italia HT2055 Step and contact meter up to 50A</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The HT Italia HT2055 is composed of a station and a meter designed to perform step/contact voltage measurements on electrical installations such as HV power stations (TN systems, electrical substations) with a rated test current of up to 50A according to international guidelines. Both units, initially synchronized in time and current, can perform an exact calculation of step and contact voltage values, applying the real test current measured by the station. An internal DSP filter also performs the automatic compensation of noise voltage disturbances affecting the measuring circuit. The instrument also permits measurement of ground resistance with 3-wire method and ground/soil resistivity with the 4-wire Wenner method. All results can be saved into the instrument&#8217;s internal memory and downloaded to a PC through the Windows software.</p>
<p><strong>HT Italia HT2055 Functions:</strong></p>
<ul>
<li>Measurement of Step/Contact voltage through separate units</li>
<li>Synchronization between units</li>
<li>Test current up to 50A</li>
<li>LCD dot matrix display on both units</li>
<li>Earth resistance measurement</li>
<li>Ground resistivity measurement</li>
<li>Internal memory for data storage</li>
<li>USB and RS-232 ports for communication between units and PC</li>
<li>DSP filtering for compensation of noise disturbances</li>
<li>Dedicated Windows software</li>
</ul>
<p><strong>HT Italia HT2055 Standard Accessories:</strong></p>
<ul>
<li>Station unit HT2055S</li>
<li>Meter unit HT2055M</li>
<li>Power cord for HT2055S unit</li>
<li>Metal current probe, 1m length</li>
<li>Metal voltage probe, 60cm length</li>
<li>Metal plate (200x100mm), 2 pcs</li>
<li>Test cable black, 50m, 10mmq, with alligator clip, on wheel</li>
<li>Test cable black, 10m, 10mmq, with alligator clip</li>
<li>Test cable red, 50m</li>
<li>Test cable green, 10m, with alligator clip</li>
<li>Test cable red, 1m, with alligator clip</li>
<li>Test cable black, 1.5m length</li>
<li>Test cable black, with plug for HT2055M, 2x3m</li>
<li>Alligator clip black, 4 pcs</li>
<li>Rechargeable battery NiMH type AA, LR03, 6 pcs</li>
<li>External adapter 100-240V AC / 12V DC</li>
<li>USB cable</li>
<li>RS-232 cable</li>
<li>Windows software TeraView</li>
<li>Soft carrying bag, 2 pcs</li>
<li>Belt for use of HT2055M unit on neck</li>
<li>ISO9000 calibration certificate for HT2055M</li>
<li>ISO9000 calibration certificate for HT2055S</li>
<li>User manual</li>
<li>Carrying case</li>
</ul>
<p><strong>Optional Accessories:</strong></p>
<ul>
<li>Metal current probe, 1m length</li>
<li>Metal voltage probe, 60cm length</li>
</ul>
<h3>HT Italia HT2055 Specifications:</h3>
<div id="tab-specifications" class="tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom ui-tabs-hide">
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellcategory" colspan="3">HT Italia HT2055 ELECTRICAL SPECIFICATIONS</td>
</tr>
<tr>
<td class="speccelldata" colspan="3">Accuracy is given as ± [% readings + (number of dgt * resolution)] at reference conditions</td>
</tr>
<tr>
<td class="speccelldata" colspan="3"><strong>Step/Contact voltage measurements</strong></td>
</tr>
<tr>
<td class="speccelltitle" align="center">Measure voltage range</td>
<td class="speccelltitle" align="center">Resolution</td>
<td class="speccelltitle" align="center">Accuracy</td>
</tr>
<tr>
<td class="speccelldata" align="center">0.01 ÷ 19.99mV</td>
<td class="speccelldata" align="center">0.01mV</td>
<td class="speccelldata" rowspan="5" align="center">±(2.0% rdg + 2dgt)</td>
</tr>
<tr>
<td class="speccelldata" align="center">20.0 ÷ 199.9mV</td>
<td class="speccelldata" align="center">0.1mV</td>
</tr>
<tr>
<td class="speccelldata" align="center">200 ÷ 1999mV</td>
<td class="speccelldata" align="center">1mV</td>
</tr>
<tr>
<td class="speccelldata" align="center">2.00 ÷ 19.99V</td>
<td class="speccelldata" align="center">0.01V</td>
</tr>
<tr>
<td class="speccelldata" align="center">20.0 ÷ 59.9V</td>
<td class="speccelldata" align="center">0.1V</td>
</tr>
<tr>
<td class="speccelltitle" align="center">Calculated voltage range</td>
<td class="speccelltitle" align="center">Resolution</td>
<td class="speccelltitle" align="center">Accuracy</td>
</tr>
<tr>
<td class="speccelldata" align="center">0.0 ÷ 199.9V</td>
<td class="speccelldata" align="center">0.1V</td>
<td class="speccelldata" rowspan="2" align="center">Calculated value (*)</td>
</tr>
<tr>
<td class="speccelldata" align="center">200 ÷ 999V</td>
<td class="speccelldata" align="center">1V</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccelldata" colspan="2">(*) The calculated value of step/contact voltage is obtained by the relationship: U<sub>S</sub>=Umeas ∙Iflt/Igen; U<sub>C</sub>=Umeas ∙Iflt/Igen;</td>
</tr>
<tr>
<td class="speccelltitle">Range of fault current (selectable)</td>
<td class="speccelldata">10A ÷ 200kA</td>
</tr>
<tr>
<td class="speccelltitle">Input resistance(selectable)</td>
<td class="speccelldata">1kΩ, 1MΩ</td>
</tr>
<tr>
<td class="speccelltitle">Noise reducing/erasing</td>
<td class="speccelldata">DSP filtering 55Hz, 64dB rejection on noise at 50/60Hz</td>
</tr>
</tbody>
</table>
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellcategory" colspan="2"><strong>HT ITALIA HT2055 GENERAL SPECIFICATIONS</strong></td>
</tr>
<tr>
<td class="speccellheader" colspan="2"><strong>Power unit</strong></td>
</tr>
<tr>
<td class="speccelltitle" width="180">Power supply</td>
<td class="speccelldata">230V AC (±10%), 50/60Hz</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Max. power consumption</td>
<td class="speccelldata">750VA</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Protection on power supply</td>
<td class="speccelldata">fuse T 5A / 250V (5mm x 20mm)</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Safety condition on meter</td>
<td class="speccelldata">IEC/EN61010-1</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Safety condition on test leads</td>
<td class="speccelldata">IEC/EN61010-031</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Installation over 1kVAC</td>
<td class="speccelldata">HD 637 S1</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Eart/resitivity measurements</td>
<td class="speccelldata">ANSI/IEEE Std 81</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Italian guideline</td>
<td class="speccelldata">CEI 11-1</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Spanish guideline</td>
<td class="speccelldata">RAT 2008</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Insulation</td>
<td class="speccelldata">class I</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Measurement category</td>
<td class="speccelldata">CAT II 300V, CAT IV 50V</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Pollution degree</td>
<td class="speccelldata">3</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Mechanical protection</td>
<td class="speccelldata">IP30</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Display</td>
<td class="speccelldata">LCD dot matrix (128 x 64) with backlight</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Internal memory</td>
<td class="speccelldata">1000 locations</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Generated current</td>
<td class="speccelldata">values storage for min 24h</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Comunication interface</td>
<td class="speccelldata">RS-232 (with voltmetric unit)</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Dimensions (LxWxH)</td>
<td class="speccelldata">563 x 257 x 275mm</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Weight (without accessories)</td>
<td class="speccelldata">29.5kg</td>
</tr>
<tr>
<td class="speccellheader" colspan="2"><strong>Voltmetric unit</strong></td>
</tr>
<tr>
<td class="speccelltitle" width="180">Power supply</td>
<td class="speccelldata">6&#215;1.2V rechargeable batteries NiMH type AA LR03<br />
6&#215;1.5V alkaline batteries type AA LR03</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Battery (chargeable) life</td>
<td class="speccelldata">12 hours (typical)</td>
</tr>
<tr>
<td class="speccelltitle" width="180">External power supply</td>
<td class="speccelldata">100-240V AC, 50-60Hz / 12V DC</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Safety condition on meter</td>
<td class="speccelldata">IEC/EN61010-1</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Safety condition on test leads</td>
<td class="speccelldata">IEC/EN61010-031</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Insulation</td>
<td class="speccelldata">double insulation</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Measurement category</td>
<td class="speccelldata">CAT IV 50V</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Pollution degree</td>
<td class="speccelldata">2</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Mechanical protection</td>
<td class="speccelldata">IP40</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Display</td>
<td class="speccelldata">LCD dot matrix (128 x 64) with backlight</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Auto Power OFF</td>
<td class="speccelldata">after 15 minutes of idleness (not disable)</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Internal memory</td>
<td class="speccelldata">1500 locations</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Comunication interface</td>
<td class="speccelldata">RS-232 and USB (to PC)</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Dimensions (LxLaxH):</td>
<td class="speccelldata">230 x 115 x 103mm</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Weight (with batteries)</td>
<td class="speccelldata">1.3kg</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">ENVIRONMENTAL CONDITIONS</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Reference temperature</td>
<td class="speccelldata">10°C ÷ 30°C</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Reference humidity</td>
<td class="speccelldata">35% ÷ 65%RH</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Working temperature</td>
<td class="speccelldata">0° ÷ 40°C</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Working humidity</td>
<td class="speccelldata">&lt;80%HR</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Storage temperature</td>
<td class="speccelldata">-10 ÷ 60°C</td>
</tr>
<tr>
<td class="speccelltitle" width="180">Storage humidity</td>
<td class="speccelldata">&lt; 80%HR</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
</div>
<p>&nbsp;</p>
<p>The post <a href="https://rapid-tech.com.au/ht-italia-ht2055-step-contact-meter-50a/">HT Italia HT2055 Step and contact meter up to 50A</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/ht-italia-ht2055-step-contact-meter-50a/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT Italia MACROTEST-G3  Multifunction Continuity/Earth Safety Tester</title>
		<link>https://rapid-tech.com.au/ht-italia-safety-tester-accessories/</link>
					<comments>https://rapid-tech.com.au/ht-italia-safety-tester-accessories/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:11:39 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/ht-italia-safety-tester-accessories/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-1537" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/HT_Italia_Ca.jpg" alt="HT_Italia_Ca" width="73" height="89" /></p>
<p align="justify"><span class="TXTSTANDARD"><span id="BLUE34">Macrotest G1 is an innovative multifunction installation tester capable of carrying out safety tests on civil and industrial electric systems in compliance with IEC/EN 61557-1. Its resistive TFT color touch-screen display, its icon menu, its help-on-line and its user-friendly development make the instrument extremely intuitive even for unskilled users.</span></span></p>
<p align="justify"><span class="TXTSTANDARD"><span id="BLUE34">Its numerous features grant the user a wide range of applications in the world of measurement. The multifunction installation tester allows saving all measurements into an internal memory so the saved data can be downloaded to a PC through a USB port (provided as standard) or built-in Wi-Fi interfaces with iOS and Android smartphones or tablets.</span></span></p>
<p align="justify"><span class="TXTSTANDARD">The Macrotest G3 also drives the optional IMP57 accessory to carry out high resolution (0.1mOhm) loop/line impedance measurements with prospective short-circuit current calibrations. Further possible tests consist in checking breakdown current, tripping current, I<sup>2</sup>t relative to breakers (MCB) with curves B, C, D, K and fuse type gG as well as aM and percentage voltage drop on the main power lines. Test on earth leakage relay tester RCDs up to 10 amps (with optional RCDX10 accessory).</span></p>
<p align="justify"><span class="TXTSTANDARD"><span id="BLUE34">The software supplied among standard accessories allows for printing of test reports. The multifunction tester has an Optional clamp (T2100) which permits to quickly check the resistance of earth probes without disconnection from the earth system.</span></span></p>
<h4 align="justify"><img class="alignnone size-full wp-image-1611" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="147" height="45" /></h4>
<h4 align="justify"><img class="alignnone size-full wp-image-1367" src="http://rapid-tech.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="logopdf (2)" width="58" height="58" /> <a href="http://rapid-tech.com.au/wp-content/uploads/2016/02/G3-Data-Sheet.pdf" rel="">G3 Data Sheet</a></h4>
<p><a href="https://www.youtube.com/watch?v=8GWV_-dFBLo" target="_blank" rel="noopener"><img class="alignnone size-medium wp-image-1647" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/VIDEO-300x169.jpg" alt="VIDEO" width="300" height="169" /> <img class="alignnone wp-image-1648" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/Play.jpg" alt="Play" width="80" height="60" /></a></p>
<p>The post <a href="https://rapid-tech.com.au/ht-italia-safety-tester-accessories/">HT Italia MACROTEST-G3  Multifunction Continuity/Earth Safety Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4><span style="font-size: large;">Functions</span></h4>
<ul>
<li>Continuity of protection conductors with 200mA.</li>
<li>Insulation resistance with 50V, 100V, 250V, 500V, 1000V DC.</li>
<li>Type A, AC, and B general, selective, and delayed RCDs up to 1000mA.</li>
<li>Test on earth leakage relay RCDs (with RCDX10 optional accessory).</li>
<li>Line/Fault impedance with prospective short circuit current calculation.</li>
<li>High resolution line/fault impedance (with IMP57 optional accessory).</li>
<li>Curve B, C, D, and K, (MCBs and gG and aM fuses)</li>
<li>Selection of length, type, and insulation of the cable under test.</li>
<li>Selection of tripping time of the protection device under test.</li>
<li>Earth resistance and soil resistivity with auxiliary rods.</li>
<li>Earth ground resistance (with T2100 optional accessory).</li>
<li>Non-trip earth loop impedance.</li>
<li>Phase sequence indication.</li>
<li>Voltage drop on main power lines measurement.</li>
<li>Power Analysis, Harmonic Analysis up to 25th.</li>
<li>Leakage current by means of the external transducer (HT96U optional accessory).</li>
<li>Environmental parameters (C/F, HR%, Lux) by means of optional probes.</li>
<li>TFT display with touch screen.</li>
<li>Help on-line.</li>
<li>Internal memory, USB interface to connect to a PC.</li>
<li>Built-in WiFi interface to connect to iOS and Android devices.</li>
<li>Rechargeable NiMH batteries (external battery charger).</li>
</ul>
<h4><span style="font-size: large;">Included Accessories</span></h4>
<ul>
<li><span style="font-size: small;">C2033X Cable 3-wires with Shuko plug</span></li>
<li>KITGSC5 Set 4 cables + 4 alligator clips<br />
+ 2 test leads</li>
<li>KITTERRNE Set 4 cables + 4 metal probes</li>
<li>PR400 Remote lead per activation test</li>
<li>PT400 Touch pen</li>
<li>TOPVIEW2006 Windows software<br />
+ optical/USB cable</li>
<li>BORSA2051 Soft carrying bag</li>
<li>YABAT0003000 NiHM rechargeable battery,<br />
type &#8216;AA&#8217; 1.2V,6 pcs</li>
<li>YABAT0004000 External battery charger</li>
<li>ISO9000 calibration certificate</li>
<li>Quick reference guide</li>
<li>User manual on CD-ROM</li>
</ul>
<p>The post <a href="https://rapid-tech.com.au/ht-italia-safety-tester-accessories/">HT Italia MACROTEST-G3  Multifunction Continuity/Earth Safety Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/ht-italia-safety-tester-accessories/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT Italia Macrotest G1  Multifunction Earth Tester</title>
		<link>https://rapid-tech.com.au/ht-italia-multifunction-meters/</link>
					<comments>https://rapid-tech.com.au/ht-italia-multifunction-meters/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:11:39 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/ht-italia-multifunction-meters/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-1537" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/HT_Italia_Ca.jpg" alt="HT_Italia_Ca" width="73" height="89" /></p>
<h3>Advanced multifunction device for verification of electric safety of private and industrial electric systems (CEI 64-8 AND IEC/EN61557-1)</h3>
<ul>
<li><strong>Earth resistance</strong> by voltammetric method with 2 or 3 spots in TT, TN and IT systems, overall earth resistance measurement and with clamp meter T2100 (optional).</li>
<li><strong>Ground resistivity.</strong></li>
<li><strong>Measurement of electric parameters insingle- phase</strong> installations (V,A, W, VAR, VA, PF)</li>
<li>Measurement of <strong>continuity</strong> of protection conduc-</li>
</ul>
<p>MacrotestG1 fully takes advantage of the<strong> touch-screen </strong>technology developed for MacrotestG3 and, hence, of all its settings, but its application range is for<strong>measuring earth resistance by voltammetric method</strong>, also with <strong>optional clamp T2100 and, finally, for continuity measurement of protective conductors</strong>. Cutting-edge management of measurement with indication, at the end of each safety test, of compliance or non-compliance with requirements with simple symbols <strong>OK</strong> or <strong>NOT OK</strong>.</p>
<p><img class="alignnone size-full wp-image-1611" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="147" height="45" /></p>
<p><img class="alignnone size-medium wp-image-1578" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/Symbols-c-300x139.jpg" alt="Symbols (c)" width="300" height="139" /> <img class="alignnone size-medium wp-image-1577" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/Symbols-b-300x109.jpg" alt="Symbols (b)" width="300" height="109" /> <img class="alignnone size-medium wp-image-1576" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/Symbols-a-300x113.jpg" alt="Symbols (a)" width="300" height="113" /></p>
<h4><img class="alignnone size-full wp-image-1367" src="http://rapid-tech.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="logopdf (2)" width="58" height="58" /> <a href="http://rapid-tech.com.au/wp-content/uploads/2016/02/Macrotest-G1.pdf">Macrotest G1</a></h4>
<p><a target="_blank" href="https://www.youtube.com/watch?v=Fk4RNcPspCQ" rel="noopener noreferrer"><img class="alignnone size-medium wp-image-1590" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/resistenza-di-terra.jpg__377x213_q85_crop_subsampling-2_upscale-300x169.jpg" alt="resistenza-di-terra.jpg__377x213_q85_crop_subsampling-2_upscale" width="300" height="169" /></a></p>
<p>The post <a href="https://rapid-tech.com.au/ht-italia-multifunction-meters/">HT Italia Macrotest G1  Multifunction Earth Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The HT Italia Macrotest G1 Multifunction Earth Tester is capable of carrying out safety tests on civil and industrial electric systems in compliance with IEC/EN61557-1. Its resistive TFT colour touch-screen display, its icon menu, its help-on-line and its user-friendly development make the instrument extremely intuitive even for unskilled users. Its numberless features grant the user a wide range of applications in the world of measurements.</p>
<p>The MACROTEST G1 installation tester allows saving all measures into an internal memory so transferring the saved data to a PC by means of USB (provided as standard) or built in Wi-Fi interfaces with an iOS and Android smartphones or tablets.The software supplied among standard accessories allows printing testing reports.The multifunction installation tester MACROTEST G1 has as Optional clamp T2100 permits to quickly check the resistance of earth probes without disconnection from earth system.</p>
<p><strong>More than one earth</strong><br />
The Macrotest Series easily measures <strong>earth ground resistance</strong> (2 and 3 Point Method) and <strong>soil resistivity </strong>(4 Point Method) with an easy to understand graphical user interface and color touchscreen. The meter can store internally up to <strong>999</strong> measurements. The included software enables easy data transfer to a computer, tablet or phone via built-in <strong>Wi-Fi or USB</strong> connection where it can be archived or used to generate reports.In addition to volt ampere method other testing modes can be adopted as follows:</p>
<ul>
<li><b>Stackless earth ground resistance measurement with T2100 (optional)</b><br />
HT Macrotest Series adopts an innovative method for earth resistance measurement eliminating the worry of finding a place for auxiliary earth rods. Earth resistance measurement will be easier thanks to an <strong>algorithm HTEarth</strong> storing all measurements effected with clamp T2100 and calculating earth resistance value without disconnecting rods.</li>
<li><b>Soil resistivity</b><br />
It measures soil resistivity ( ) with 4-pole Wenner method.</li>
</ul>
<h4><strong>Power and Load Analysis</strong></h4>
<ul>
<li><strong>Single Phase</strong> and <strong>Three Phase </strong>balanced systems</li>
<li><strong>Voltage,Current and frequency </strong>measurement</li>
<li><strong>Active power, reactive power</strong> and <strong>apparent power</strong> measurement</li>
<li><strong>Cosphi, power factor</strong> measurement</li>
<li><strong>THD%</strong> and <strong>Harmonics analysis</strong> up to 25 th</li>
</ul>
<h4>HT Italia Macrotest G1 Features:</h4>
<ul>
<li>Earth resistance and soil resistivity with 2/3/4 pole method</li>
<li>Stackless earth ground resistance (with T2100 optional accessory)</li>
<li>Power Analysis, Harmonic analysis up to 25th</li>
<li>Continuity of protection conductors with 200mA</li>
<li>Built-in WiFi interface to connect to iOS and Android devices</li>
<li>USB interface to connect to the PC</li>
<li>Colour touch-screen display</li>
<li>Help on-line</li>
<li>Internal memory and Cloud Storage (trough iOS or Android device)</li>
<li>Rechargeable NiMH batteries (external battery charger)</li>
</ul>
<h3>HT Italia MACROTEST G1 Specifications:</h3>
<div id="tab-specifications" class="tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom ui-tabs-hide">
<table class="spectable" cellspacing="0" cellpadding="0" align="center">
<tbody>
<tr>
<td class="speccellcategory"><strong>Functions</strong></td>
<td class="speccellcategory" align="center"><strong>MACROTEST G1</strong></td>
<td class="speccellcategory" align="center"><strong>MACROTEST G2</strong></td>
</tr>
<tr>
<td class="speccelltitle">Insulation with 1000VDC test voltage</td>
<td class="speccelldata" align="center"></td>
<td class="speccelldata" align="center"><img decoding="async" src="http://assets.tequipment.net/assets/1/7/checkmark.png" alt="" /></td>
</tr>
<tr>
<td class="speccelltitle">Insulation with 500VDC test voltage</td>
<td class="speccelldata" align="center"></td>
<td class="speccelldata" align="center"><img decoding="async" src="http://assets.tequipment.net/assets/1/7/checkmark.png" alt="" /></td>
</tr>
<tr>
<td class="speccelltitle">Insulation with 250VDC test voltage</td>
<td class="speccelldata" align="center"></td>
<td class="speccelldata" align="center"><img decoding="async" src="http://assets.tequipment.net/assets/1/7/checkmark.png" alt="" /></td>
</tr>
<tr>
<td class="speccelltitle">Insulation with 50, 100VDC test voltage</td>
<td class="speccelldata" align="center"></td>
<td class="speccelldata" align="center"><img decoding="async" src="http://assets.tequipment.net/assets/1/7/checkmark.png" alt="" /></td>
</tr>
<tr>
<td class="speccelltitle">Continuity of earth conductors with 200mA</td>
<td class="speccelldata" align="center"><img decoding="async" src="http://assets.tequipment.net/assets/1/7/checkmark.png" alt="" /></td>
<td class="speccelldata" align="center"><img decoding="async" src="http://assets.tequipment.net/assets/1/7/checkmark.png" alt="" /></td>
</tr>
<tr>
<td class="speccelltitle">Earth resistance with 2-pole and 3-pole</td>
<td class="speccelldata" align="center"><img decoding="async" src="http://assets.tequipment.net/assets/1/7/checkmark.png" alt="" /></td>
<td class="speccelldata" align="center"><img decoding="async" src="http://assets.tequipment.net/assets/1/7/checkmark.png" alt="" /></td>
</tr>
<tr>
<td class="speccelltitle">Earth resistance with ring mode</td>
<td class="speccelldata" align="center"><img decoding="async" src="http://assets.tequipment.net/assets/1/7/checkmark.png" alt="" />**</td>
<td class="speccelldata" align="center"><img decoding="async" src="http://assets.tequipment.net/assets/1/7/checkmark.png" alt="" />**</td>
</tr>
<tr>
<td class="speccelltitle">Ground resistivity with 4-pole</td>
<td class="speccelldata" align="center"><img decoding="async" src="http://assets.tequipment.net/assets/1/7/checkmark.png" alt="" /></td>
<td class="speccelldata" align="center"><img decoding="async" src="http://assets.tequipment.net/assets/1/7/checkmark.png" alt="" /></td>
</tr>
<tr>
<td class="speccelltitle">Measurement of electrical parameters (V, A, W, VAR, VA, PF)</td>
<td class="speccelldata" align="center"><img decoding="async" src="http://assets.tequipment.net/assets/1/7/checkmark.png" alt="" /><sup>1</sup></td>
<td class="speccelldata" align="center"><img decoding="async" src="http://assets.tequipment.net/assets/1/7/checkmark.png" alt="" /><sup>1</sup></td>
</tr>
<tr>
<td class="speccelltitle">Harmonic analysis up to 25<sup>th</sup> order and THD% calculation</td>
<td class="speccelldata" align="center"><img decoding="async" src="http://assets.tequipment.net/assets/1/7/checkmark.png" alt="" />(25th)<sup>1</sup></td>
<td class="speccelldata" align="center"><img decoding="async" src="http://assets.tequipment.net/assets/1/7/checkmark.png" alt="" />(25th)<sup>1</sup></td>
</tr>
<tr>
<td class="speccelltitle">Help on line</td>
<td class="speccelldata" align="center"><img decoding="async" src="http://assets.tequipment.net/assets/1/7/checkmark.png" alt="" /></td>
<td class="speccelldata" align="center"><img decoding="async" src="http://assets.tequipment.net/assets/1/7/checkmark.png" alt="" /></td>
</tr>
<tr>
<td class="speccelltitle">Internal memory to save measures</td>
<td class="speccelldata" align="center"><img decoding="async" src="http://assets.tequipment.net/assets/1/7/checkmark.png" alt="" /></td>
<td class="speccelldata" align="center"><img decoding="async" src="http://assets.tequipment.net/assets/1/7/checkmark.png" alt="" /></td>
</tr>
<tr>
<td class="speccelltitle">Optical/USB port for PC connection</td>
<td class="speccelldata" align="center"><img decoding="async" src="http://assets.tequipment.net/assets/1/7/checkmark.png" alt="" /></td>
<td class="speccelldata" align="center"><img decoding="async" src="http://assets.tequipment.net/assets/1/7/checkmark.png" alt="" /></td>
</tr>
<tr>
<td class="speccelltitle">Built-in WiFi communication interface</td>
<td class="speccelldata" align="center"><img decoding="async" src="http://assets.tequipment.net/assets/1/7/checkmark.png" alt="" /></td>
<td class="speccelldata" align="center"><img decoding="async" src="http://assets.tequipment.net/assets/1/7/checkmark.png" alt="" /></td>
</tr>
<tr>
<td class="speccelltitle">Hard carrying case</td>
<td class="speccelldata" align="center">Optional</td>
<td class="speccelldata" align="center">Optional</td>
</tr>
</tbody>
</table>
<table class="spectable" cellspacing="0" cellpadding="0" align="center">
<tbody>
<tr>
<td class="speccellcategory" colspan="4"><strong>Technical Specifications:</strong></td>
</tr>
<tr>
<td class="speccellheader" colspan="4">Continuity with 200mA</td>
</tr>
<tr>
<td class="speccelltitle" colspan="2">Measuring range</td>
<td class="speccelldata" colspan="2">0,01Ω÷99.9Ω</td>
</tr>
<tr>
<td class="speccelltitle" colspan="2">Accuracy</td>
<td class="speccelldata" colspan="2">±(5.0% reading + 3 digits)</td>
</tr>
<tr>
<td class="speccelltitle" colspan="2">Test current</td>
<td class="speccelldata" colspan="2">&gt; 200mA (R ≤ 2Ω)</td>
</tr>
<tr>
<td class="speccelltitle" colspan="2">Open circuit voltage</td>
<td class="speccelldata" colspan="2">4V ≤ V<sub>0</sub>≤ 12V</td>
</tr>
<tr>
<td class="speccellheader" colspan="4">Insulation resistance</td>
</tr>
<tr>
<td class="speccelltitle" colspan="2">Test voltage</td>
<td class="speccelldata" colspan="2">50, 100, 250, 500, 1000VDC</td>
</tr>
<tr>
<td class="speccelltitle" colspan="2">Measuring range</td>
<td class="speccelldata" colspan="2">0.01MΩ ÷ 99.9MΩ (50V)<br />
0.01MΩ ÷ 199.9MΩ (100V)<br />
0.01MΩ ÷ 499MΩ (250V)<br />
0.01MΩ ÷ 999MΩ (500V)<br />
0.01MΩ ÷ 1999MΩ (1000V)</td>
</tr>
<tr>
<td class="speccelltitle" colspan="2">Basic accuracy</td>
<td class="speccelldata" colspan="2">±(2.0% reading + 2 digits)</td>
</tr>
<tr>
<td class="speccelltitle" colspan="2">Test current</td>
<td class="speccelldata" colspan="2">&gt; 1mA on 1kΩ x Vnom (50,100, 250, 1kV)<br />
&gt; 2.2mA on 230kΩ @ 500V</td>
</tr>
<tr>
<td class="speccelltitle" colspan="2">Short circuit current</td>
<td class="speccelldata" colspan="2">&lt;6.0mA for each test voltage</td>
</tr>
<tr>
<td class="speccellheader" colspan="4">Line/Loop Impedance (L-L, L-N, L-PE)</td>
</tr>
<tr>
<td class="speccelltitle" colspan="2">Measuring range</td>
<td class="speccelldata" colspan="2">0.01Ω ÷ 199.9Ω</td>
</tr>
<tr>
<td class="speccelltitle" colspan="2">Resolution</td>
<td class="speccelldata" colspan="2">0.01Ω min (0.1mΩ with optional accessory IMP57)</td>
</tr>
<tr>
<td class="speccelltitle" colspan="2">Accuracy</td>
<td class="speccelldata" colspan="2">±(5.0% reading + 3 digits)</td>
</tr>
<tr>
<td class="speccelltitle" colspan="2">Test voltage</td>
<td class="speccelldata" colspan="2">100÷265V (L-N) / 100÷460V (L-L), 50/60Hz</td>
</tr>
<tr>
<td class="speccelltitle" colspan="2">Maximum test current</td>
<td class="speccelldata" colspan="2">5.81A (@265V); 10.10A (@457V)</td>
</tr>
<tr>
<td class="speccelltitle" colspan="2">Selectable MCB protections</td>
<td class="speccelldata" colspan="2">curves B, C, D, K</td>
</tr>
<tr>
<td class="speccelltitle" colspan="2">Selectable fuse protections</td>
<td class="speccelldata" colspan="2">type aM and gG</td>
</tr>
<tr>
<td class="speccelltitle" colspan="2">Insulating material (test I2t)</td>
<td class="speccelldata" colspan="2">PVC, butyl rubber, EPR, XLPE</td>
</tr>
<tr>
<td class="speccellheader" colspan="4">Earth resistance and ground resistivity</td>
</tr>
<tr>
<td class="speccelltitle" colspan="2">Measuring range R</td>
<td class="speccelldata" colspan="2">0.01Ω ÷ 49.99kΩ</td>
</tr>
<tr>
<td class="speccelltitle" colspan="2">Measuring range</td>
<td class="speccelldata" colspan="2">0.60Ωm÷3.14MΩm</td>
</tr>
<tr>
<td class="speccelltitle" colspan="2">Accuracy</td>
<td class="speccelldata" colspan="2">±(5.0%reading + 3digits)</td>
</tr>
<tr>
<td class="speccelltitle" colspan="2">Test current</td>
<td class="speccelldata" colspan="2">10mA, 77.5Hz</td>
</tr>
<tr>
<td class="speccelltitle" colspan="2">Open circuit voltage</td>
<td class="speccelldata" colspan="2">&lt;20Vrms</td>
</tr>
<tr>
<td class="speccellheader" colspan="4">Measurement of environmental parameters (with optional probes)</td>
</tr>
<tr>
<td class="speccelltitle" colspan="2">Air temperature (°C/°F)</td>
<td class="speccelldata" colspan="2">-20.0 ÷ 60.0 °C / -4.0 ÷ 140.0 °F</td>
</tr>
<tr>
<td class="speccelltitle" colspan="2">Relative humidity</td>
<td class="speccelldata" colspan="2">0% ÷ 100%RH</td>
</tr>
<tr>
<td class="speccelltitle" colspan="2">Illuminance (Lux)</td>
<td class="speccelldata" colspan="2">0.001lux ÷ 20klux</td>
</tr>
<tr>
<td class="speccelltitle" colspan="2">Accuracy</td>
<td class="speccelldata" colspan="2">±(2.0% reading + 2 digits)</td>
</tr>
</tbody>
</table>
<table class="spectable" cellspacing="0" cellpadding="0" align="center">
<tbody>
<tr>
<td class="speccellheader" colspan="2"><strong>General Specifications</strong></td>
</tr>
<tr>
<td class="speccelltitle">Power supply</td>
<td class="speccelldata">6&#215;1.2V rechargeable type AA NiMH<br />
or 6&#215;1.5V type AA alkaline</td>
</tr>
<tr>
<td class="speccelltitle">Battery life</td>
<td class="speccelldata">&gt; 550 test (alKaline)</td>
</tr>
<tr>
<td class="speccelltitle">Display</td>
<td class="speccelldata">320&#215;240 resistive color LCD with touch screen</td>
</tr>
<tr>
<td class="speccelltitle">Memory</td>
<td class="speccelldata">999 locations, 3 marker levels</td>
</tr>
<tr>
<td class="speccelltitle">PC interface</td>
<td class="speccelldata">optical/USB and Wi-Fi (with optional accessory C2013)</td>
</tr>
<tr>
<td class="speccelltitle">Dimensions (L x D x H)</td>
<td class="speccelldata">225 x 165 x 75 mm / 8.8 x 6.5 x 2.9 in</td>
</tr>
<tr>
<td class="speccelltitle">Weight (including batteries)</td>
<td class="speccelldata">1.2 kg / 2.5 lb</td>
</tr>
<tr>
<td class="speccelltitle">Safety</td>
<td class="speccelldata">IEC/EN61010-1, double insulation</td>
</tr>
<tr>
<td class="speccelltitle">Pollution degree</td>
<td class="speccelldata">2</td>
</tr>
<tr>
<td class="speccelltitle">Mechanical protection</td>
<td class="speccelldata">CAT III 240V, max 415V among inputs</td>
</tr>
<tr>
<td class="speccelltitle">Reference standards</td>
<td class="speccelldata">IEC/EN61557-1-2-3-4-5-6-7</td>
</tr>
<tr>
<td class="speccelltitle">Working temperature</td>
<td class="speccelldata">0°÷ 40°C / 32°÷104°F</td>
</tr>
<tr>
<td class="speccelltitle">Working humidity</td>
<td class="speccelldata">&lt;80%RH</td>
</tr>
<tr>
<td class="speccelltitle">Storage temp.</td>
<td class="speccelldata">-10°÷ 60°C / 14°÷140°F</td>
</tr>
<tr>
<td class="speccelltitle">Storage humidity</td>
<td class="speccelldata">&lt;80%RH</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://rapid-tech.com.au/ht-italia-multifunction-meters/">HT Italia Macrotest G1  Multifunction Earth Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/ht-italia-multifunction-meters/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT Italia MACROTEST G1-KIT 4-Pole Earth Tester with T2100 Stakeless Clamp</title>
		<link>https://rapid-tech.com.au/ht-italia-digital-multimeters/</link>
					<comments>https://rapid-tech.com.au/ht-italia-digital-multimeters/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:11:39 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/ht-italia-digital-multimeters/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-1537" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/HT_Italia_Ca.jpg" alt="HT_Italia_Ca" width="73" height="89" /></p>
<p>&#160;</p>
<p>MACROTEST G1 is an innovative multifunction installation tester capable of carrying out safety tests on civil and industrial electric systems in compliance with IEC/EN61557-1. Its resistive TFT color touch-screen display, its icon menu, its help-on-line and its user-friendly development make the instrument extremely intuitive even for unskilled users. Its numberless features grant the user a wide range of applications in the world of measurements.The multifunction installation tester MACROTEST G2 allows saving all measures into an internal memory so transferring the saved data to a PC by means of USB (provided as standard) or built in Wi-Fi interfaces with an iOS and Android smartphones or tablets .The software supplied among standard accessories allows printing testing reports.The multifunction installation tester MACROTESTG1 has as Optional clamp T2100 permits to quickly check the resistance of earth probes without disconnection from earth system.</p>
<p><img class="alignnone size-full wp-image-1611" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="147" height="45" /></p>
<p><img class="alignnone size-medium wp-image-1578" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/Symbols-c-300x139.jpg" alt="Symbols (c)" width="300" height="139" /> <img class="alignnone size-medium wp-image-1577" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/Symbols-b-300x109.jpg" alt="Symbols (b)" width="300" height="109" /> <img class="alignnone size-medium wp-image-1576" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/Symbols-a-300x113.jpg" alt="Symbols (a)" width="300" height="113" /></p>
<h4><img class="alignnone size-full wp-image-1367" src="http://rapid-tech.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="logopdf (2)" width="58" height="58" /> <a href="http://rapid-tech.com.au/wp-content/uploads/2016/02/HT_Instruments_MACROTESTG2_Data_Sheet.pdf" rel="">HT_Instruments_MACROTESTG2_Data_Sheet</a></h4>
<h4><a href="http://rapid-tech.com.au/wp-content/uploads/2016/02/T2100-datasheet.pdf" rel=""><img class="alignnone size-full wp-image-1367" src="http://rapid-tech.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="logopdf (2)" width="58" height="58" />T2100 datasheet</a></h4>
<p>The post <a href="https://rapid-tech.com.au/ht-italia-digital-multimeters/">HT Italia MACROTEST G1-KIT 4-Pole Earth Tester with T2100 Stakeless Clamp</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="productDetails">
<div class="itemDesc">
<div id="pShortDesc">MACROTEST G1 + T2100 Clamp + V504 Hard Case</div>
</div>
</div>
<div class="block"></div>
<div class="itemDesc">
<h4>Features</h4>
<ul>
<li>Earth resistance and soil resistivity with 2/3/4 pole method</li>
<li>Stackless earth ground resistance (with T2100 optional accessory)</li>
<li>Power Analysis, Harmonic analysis up to 25th</li>
<li>Continuity of protection conductors with 200mA</li>
<li>Built-in WiFi interface to connect to iOS and Android devices</li>
<li>USB interface to connect to the PC</li>
<li>Color touch-screen display</li>
<li>Help on-line</li>
<li>Internal memory and Cloud Storage (trough iOS or Android device)</li>
<li>Rechargeable NiMH batteries (external battery charger)</li>
</ul>
<p><strong>T2100 Earth Ground Clamp Meter with RS-232 Interface</strong></p>
<ul>
<li>Resistance measurement on earth probes by means of ground loop method</li>
<li>Direct measurement on earth probes without any cable breaking</li>
<li>RS-232 serial interface for connection with MACROTESTG3</li>
<li>Calculation of parallel resistance of all earth probes</li>
<li>Setting of alarm thresholds on measurements</li>
<li>Storage of measurement results</li>
<li>Detection of current noise on measurements</li>
<li>Data HOLD function</li>
<li>Backlight</li>
<li>Auto Power OFF</li>
</ul>
<h3>What&#8217;s In The Box</h3>
<div id="tab-what_s_in_the_box" class="tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom ui-tabs-hide">
<p><strong>MACROTESTG1 Ground Resistance and Bonding Continuity Tester</strong></p>
<ul>
<li>C2033X  3-banana to Shuko plug cable</li>
<li>KITGSC5  Kit including 4 cables, 4 alligator clips and 2 test leads</li>
<li>KITTERRNE  Soft carrying bag containing 4 cables and 4 earth rods</li>
<li>PT400  Stylus</li>
<li>BORSA2051  Soft carrying bag</li>
<li>TOPVIEW2006  PC software and optical-to-USB connection cable C2006</li>
<li>YABAT0003000  Rechargeable NiMH battery 1.2V, AA, 6 pcs</li>
<li>Quick user’s guide</li>
<li>User’s manual  on CD-ROM</li>
<li>Calibration certiﬁcate  ISO9000</li>
</ul>
<p><strong>T2100 Earth Ground Clamp Meter with RS-232 Interface</strong></p>
<ul>
<li>Resistive test loop</li>
<li>RS-232 cable</li>
<li>Batteries</li>
<li>ISO9000 calibration certificate</li>
<li>User manual</li>
<li>Carrying case</li>
</ul>
<p><strong>VA 504 Hard Carry Case</strong></p>
</div>
</div>
<p>The post <a href="https://rapid-tech.com.au/ht-italia-digital-multimeters/">HT Italia MACROTEST G1-KIT 4-Pole Earth Tester with T2100 Stakeless Clamp</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/ht-italia-digital-multimeters/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT Italia GEO 416  Earth Resistance and Ground Resistivity Tester with Data Download</title>
		<link>https://rapid-tech.com.au/ht-italia-photovoltaic-testers/</link>
					<comments>https://rapid-tech.com.au/ht-italia-photovoltaic-testers/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:11:39 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/ht-italia-photovoltaic-testers/</guid>

					<description><![CDATA[<p>&#160;</p>
<p><img class="alignnone size-full wp-image-1537" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/HT_Italia_Ca.jpg" alt="HT_Italia_Ca" width="73" height="89" /></p>
<p><a target="_blank" href="https://mymeter.com.au/product/ht-italia-geo416/" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<h4>GEO416 has been developed to measure <strong>earth resistance with 2 wires</strong>, <strong>3 wires and 4 wires</strong> by <strong>voltammetric method</strong> and ground resistivity. These values are extremely important while designing earth systems.</h4>
<p>The 2-wire method, by taking advantage of appropriate external masses as a reference (metal surfaces, tubes, neutral conductor, etc.), is particularly useful in private environments where, because of logistic problems, it is not possible to use the 3-wire method. The device allows carrying out <strong>measurements with a wide measuring range (up to 50kOhm)</strong> with an efficient internal compensation of the disturbance effects found on the installations. GEO416 is provided with an <strong>internal memory</strong> <strong>for saving measurements</strong> and with an <strong>optical/USB interface for transferring</strong> measured data onto the PC</p>
<p><img class="alignnone size-full wp-image-1611" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="147" height="45" /></p>
<h4><img class="alignnone size-full wp-image-1367" src="http://rapid-tech.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="logopdf (2)" width="58" height="58" /> <a href="http://rapid-tech.com.au/wp-content/uploads/2016/02/GEO-416-Data-Sheet.pdf">GEO 416 Data Sheet</a></h4>
<p>The post <a href="https://rapid-tech.com.au/ht-italia-photovoltaic-testers/">HT Italia GEO 416  Earth Resistance and Ground Resistivity Tester with Data Download</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The HT Italia GEO 416 Earth Resistance and Ground Resistivity Tester designed to performing Earth Resistance measurements with 3-pole standards method typically in industrial electrical installations environments which consists of single probes and more or less wide earth networks. This meter can perform also 2-pole measure (where auxiliary metal parts are available) extremely important in civil environments where 3-pole method application is not possible for logistical reasons.</p>
<p>The HT Italia GEO 416 performs tests with a high measurement range (up to 50kOhm) with a test current at high frequency in order to consider and eliminate noise voltages disturb on installation. Earth Resistivity test measure with 4-wire method it’s also very useful on preliminary calculation of earth installation dimension. A contextual help selectable by user it’s available on meter for each functions. The model can save each test result inside memory and can transfer saved dates to PC through optical / USB interface with dedicated Windows software.</p>
<h4><span style="font-size: 110%;">HT Italia GEO 416 Features:</span></h4>
<ul>
<li>2-pole Earth Resistance</li>
<li>3-pole Earth Resistance</li>
<li>4-pole Earth Resistivity</li>
<li>High measurement range (50kOhm)</li>
<li>Noise voltage measure</li>
<li>Automatic calibration of test cables resistance</li>
<li>Memory for saving tests</li>
<li>Backlight</li>
<li>Optical /USB PC interface</li>
</ul>
<h4><span style="font-size: 110%;">What&#8217;s In The Box</span></h4>
<div id="tab-what_s_in_the_box" class="tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom ui-tabs-hide">
<ul>
<li>KITTERRNE : Set 4 cables + 4 metal probes</li>
<li>COC4-UK : Set of 4 alligator clips</li>
<li>BORSA2000N : Carrying bag for accessories</li>
<li>ISO9000 calibration certificate</li>
<li>User manual</li>
</ul>
<h4><span style="font-size: 110%;">HT Italia GEO 416 Specifications:</span></h4>
<div id="tab-specifications" class="tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom ui-tabs-hide">
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellheader" colspan="3">HT Instruments GEO 416 Specifications</td>
</tr>
<tr>
<td class="speccellcategory" colspan="3">Electrical Specifications</td>
</tr>
<tr>
<td class="speccelldata" colspan="3" align="center">Accuracy in indicated as ± (% of reading + number of digits) at 23°C ± 5°C ; &lt;60%HR</td>
</tr>
<tr>
<td class="speccellcategory" colspan="3">Earth Resistance 3-wire and 2-wire systems</td>
</tr>
<tr>
<td class="speccelltitle" align="center">Range (Ω)</td>
<td class="speccelltitle" align="center">Resolution (Ω)</td>
<td class="speccelltitle" align="center">Accuracy</td>
</tr>
<tr>
<td class="speccelldata" align="center">0.01 ÷ 19.99</td>
<td class="speccelldata" align="center">0.01</td>
<td class="speccelldata" rowspan="5" align="center">±(2.5%rdg + 2dgt)</td>
</tr>
<tr>
<td class="speccelldata" align="center">20.0 ÷ 199.9</td>
<td class="speccelldata" align="center">0.1</td>
</tr>
<tr>
<td class="speccelldata" align="center">200 ÷ 1999</td>
<td class="speccelldata" align="center">1</td>
</tr>
<tr>
<td class="speccelldata" align="center">2.00 ÷ 19.99k</td>
<td class="speccelldata" align="center">0.01k</td>
</tr>
<tr>
<td class="speccelldata" align="center">20.0 ÷ 49.9k</td>
<td class="speccelldata" align="center">0.1k</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Test current:</td>
<td class="speccelldata" colspan="2" align="center">≤12mAAC</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Open circuit voltage:</td>
<td class="speccelldata" colspan="2" align="center">≤25V ACTRMS</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Test frequency:</td>
<td class="speccelldata" colspan="2" align="center">77.5Hz ± 1Hz</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Rprobes:</td>
<td class="speccelldata" colspan="2" align="center">≤50kΩ</td>
</tr>
<tr>
<td class="speccellcategory" colspan="3">Earth Resistivity ρ with 4-wire method</td>
</tr>
<tr>
<td class="speccelltitle" align="center">Range (Ωm)</td>
<td class="speccelltitle" align="center">Resolution (Ωm)</td>
<td class="speccelltitle" align="center">Accuracy</td>
</tr>
<tr>
<td class="speccelldata" align="center">0.06 ÷ 19.99</td>
<td class="speccelldata" align="center">0.01</td>
<td class="speccelldata" rowspan="6" align="center">±(2.5%rdg + 2dgt)</td>
</tr>
<tr>
<td class="speccelldata" align="center">20.0 ÷ 199.9</td>
<td class="speccelldata" align="center">0.1</td>
</tr>
<tr>
<td class="speccelldata" align="center">200 ÷ 1999</td>
<td class="speccelldata" align="center">1</td>
</tr>
<tr>
<td class="speccelldata" align="center">2.00 ÷ 19.99k</td>
<td class="speccelldata" align="center">0.01k</td>
</tr>
<tr>
<td class="speccelldata" align="center">20.0 ÷ 199.9k</td>
<td class="speccelldata" align="center">0.1k</td>
</tr>
<tr>
<td class="speccelldata" align="center">0.20 ÷ 3.15M</td>
<td class="speccelldata" align="center">0.01M</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Test current:</td>
<td class="speccelldata" colspan="2" align="center">≤12mAAC</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Open circuit voltage:</td>
<td class="speccelldata" colspan="2" align="center">≤25V ACTRMS</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Test frequency:</td>
<td class="speccelldata" colspan="2" align="center">77.5Hz ± 1Hz</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Probe distance range:</td>
<td class="speccelldata" colspan="2" align="center">1÷10m</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Rprobes:</td>
<td class="speccelldata" colspan="2" align="center">≤50kΩ</td>
</tr>
<tr>
<td class="speccellcategory" colspan="3">Noise Voltages</td>
</tr>
<tr>
<td class="speccelltitle" align="center">Range (V)</td>
<td class="speccelltitle" align="center">Resolution (V)</td>
<td class="speccelltitle" align="center">Accuracy</td>
</tr>
<tr>
<td class="speccelldata" align="center">460</td>
<td class="speccelldata" align="center">1</td>
<td class="speccelldata" align="center">±(2.0%rdg + 2dgt)</td>
</tr>
</tbody>
</table>
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellheader" colspan="2">General Specifications</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Display, Memory, Serial Interface:</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Features:</td>
<td class="speccelldata" align="center">Custom LCD with backlight</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Visible area:</td>
<td class="speccelldata" align="center">73&#215;65 mm</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Memory:</td>
<td class="speccelldata" align="center">999 locations</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Serial interface:</td>
<td class="speccelldata" align="center">RS-232 /USB</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Power Supply:</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Batteries:</td>
<td class="speccelldata" align="center">6 batteries 1.5V type LR6-AA-AM3-MN 1500</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Low batteries indications:</td>
<td class="speccelldata" align="center">battery symbol at display</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Batteries life:</td>
<td class="speccelldata" align="center">about 500 test</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Mechanical Features:</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Dimensions:</td>
<td class="speccelldata" align="center">222 (W) x 162(L) x 57(D) mm</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Weight (included batteries):</td>
<td class="speccelldata" align="center">about 1kg</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Working Environmental Conditions:</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Reference temperature:</td>
<td class="speccelldata" align="center">23°C ± 5°C</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Working temperature:</td>
<td class="speccelldata" align="center">0° ÷ 40°C</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Allowed relative humidity:</td>
<td class="speccelldata" align="center">&lt;80%HR</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Storage temperature:</td>
<td class="speccelldata" align="center">-10 ÷ 60°C</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Storage humidity:</td>
<td class="speccelldata" align="center">&lt;80%HR</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">General Reference Standards:</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Safety of measuring instruments:</td>
<td class="speccelldata" align="center">IEC / EN61010-1</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Safety of accessories:</td>
<td class="speccelldata" align="center">IEC / EN61010-031</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Product type standard:</td>
<td class="speccelldata" align="center">IEC / EN61557-1, IEC / EN61557-5</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Insulation:</td>
<td class="speccelldata" align="center">double insulation</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Pollution degree:</td>
<td class="speccelldata" align="center">2</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Overvoltage category:</td>
<td class="speccelldata" align="center">CAT III 240V to ground, 415V between inputs</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Max altitude:</td>
<td class="speccelldata" align="center">2000m</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">EMC:</td>
<td class="speccelldata" align="center">EN61326-1(1998) + A1(1999)</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://rapid-tech.com.au/ht-italia-photovoltaic-testers/">HT Italia GEO 416  Earth Resistance and Ground Resistivity Tester with Data Download</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/ht-italia-photovoltaic-testers/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT Italia T2000 Clamp on Ground Resistance Tester</title>
		<link>https://rapid-tech.com.au/ht-italia-dataloggers/</link>
					<comments>https://rapid-tech.com.au/ht-italia-dataloggers/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:11:38 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/ht-italia-dataloggers/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-1537" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/HT_Italia_Ca.jpg" alt="HT_Italia_Ca" width="73" height="89" /></p>
<h3>T2000 clamp is <strong>specially developed to evaluate resistance of earth rods with no need to disconnect any part of the system (STAKELESS METHOD)</strong></h3>
<p>The inner part of the device is made of 2 jaws, one for current reading and the other for voltage generation. The voltage jaws generate a potential (E) on the loop during resistance (R) measurement. A current (I) is consequently generated on the loop and is measured by the current jaws.</p>
<p>Based on the value of parameters E and I, the instrument displays the resistance R value calculated as their ratio. The value measured by the device can be used in case the single rods do not influence each other. T2000 also measures <strong>AC current up to 20A</strong> and <strong>leakage current with resolution 0.05mA</strong>.</p>
<p>This device complies with standard <strong>IEC/EN61010-1</strong> in <strong>CAT III 150V</strong> and it is the ideal solution for measurements to be carried out both in private and in industrial environments.</p>
<p><img class="alignnone size-full wp-image-1611" src="http://rapid-tech.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="147" height="45" /></p>
<h3><img class="alignnone size-full wp-image-1367" src="http://rapid-tech.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="logopdf (2)" width="58" height="58" /> <span style="text-decoration: underline;"><a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2016/02/T2000-Data-Sheet.pdf" rel="noopener noreferrer">T2000 Data Sheet</a></span></h3>
<p>The post <a href="https://rapid-tech.com.au/ht-italia-dataloggers/">HT Italia T2000 Clamp on Ground Resistance Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>HT IItalia T2000 Earth Ground Clamp Meter</strong></p>
<p>The HTI T2000 Earth Ground Clamp Meter is designed for the resistance measurement on earth probes with ground loop method without the disconnection of parts of plants under test.</p>
<p>This type of measurement carried out by the instrument can be used for evaluation of single rods’ resistances within an earth installation assuming they do not affect each other. The inner part of the instrument is made of 2 jaws one for current and one for voltage. The voltage jaw generates a potential (E) on the loop during resistance measurement. A current (I) is consequently generated on the loop and is measured by the current jaw. Based on the value of parameters E and I the instrument displays the resistance value R calculated as their ratio.</p>
<p>The T2000 also performs AC current up to 20A and leakage current with 0.05mA resolution and the setting of alarm thresholds on measurements is possible. The instrument is in compliance with IEC/EN61010-1, CAT III 150V and is ideal to carry out easily measurements both in domestic and industrial environments.</p>
<h4>HTI T2000 Features:</h4>
<ul>
<li>Resistance measurement on earth probes with ground loop method</li>
<li>Direct measurement on earth probes without any cable breaking</li>
<li>Measurement of leakage current on earth installations</li>
<li>Setting of alarm thresholds on measurements with buzzer</li>
<li>Storage of measurement results</li>
<li>Detection of current noise on measurement</li>
<li>Data HOLD function</li>
<li>Backlight</li>
<li>Auto Power OFF</li>
</ul>
<h3>HT T2000 Specifications</h3>
<div id="tab-specifications" class="tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom ui-tabs-hide">
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellcategory" colspan="2">Mechanical characteristics</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Dimensions (L x W x H)</td>
<td class="speccelldata">293 x 90 x 66mm</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Weight (including battery)</td>
<td class="speccelldata">1320g</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Max conductor size</td>
<td class="speccelldata">32mm</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Supply</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Battery type</td>
<td class="speccelldata">4 x1.5V alkaline LR6 AA MN1500</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Auto power OFF</td>
<td class="speccelldata">about 5 minutes of idleness</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Display</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Characteristics</td>
<td class="speccelldata">4 LCD, sign and decimal point with backlight</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Sample rate</td>
<td class="speccelldata">1 times/sec</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Internal memory</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Memory capacity</td>
<td class="speccelldata">99 locations</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Climatic conditions</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Reference temperature</td>
<td class="speccelldata">20°C +/- 3°C</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Operating temperature</td>
<td class="speccelldata">0 &#8211; 40°C</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Operating humidity</td>
<td class="speccelldata">10%RH &#8211; 90%RH</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Reference standards</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Comply with</td>
<td class="speccelldata">IEC/EN 61010-1, IEC/EN61010-2-032</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Insulation</td>
<td class="speccelldata">double insulation</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Pollution degree</td>
<td class="speccelldata">2</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Max height of use</td>
<td class="speccelldata">2000m</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Installation category</td>
<td class="speccelldata">CAT III 150V to ground, max 20A</td>
</tr>
</tbody>
</table>
</div>