<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Clampmeters Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/clampmeters-portablehandheld/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/clampmeters-portablehandheld/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Sat, 06 Dec 2025 01:47:35 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.10</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>Clampmeters Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/clampmeters-portablehandheld/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Yokogawa CL255 True RMS AC/DC 2000A Clamp Meter</title>
		<link>https://rapid-tech.com.au/yokogawa-cl255-true-rms-acdc-2000a-clamp-meter/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Fri, 03 Nov 2017 17:14:13 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=5784</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/10/Yokogawa-Logo-Medium.jpg"><img class="alignnone size-full wp-image-5623" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/Yokogawa-Logo-Medium.jpg" alt="" width="250" height="50" /></a></p>
<p>&#160;</p>
<p><a target="_blank" href="https://mymeter.com.au/product/yokogawa-cl255-true-rms-2000a-acdc-clamp-meter/" rel="noopener"><img class="alignnone size-full wp-image-17843" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/BUY-NOW-form-My-Meter-e1620004827208.png" alt="Buy now form My Meter" width="220" height="55" /></a></p>
<ul>
<li>True RMS display</li>
<li>AC/DC current measurements with current ranges up to 2000A</li>
<li>AC/DC voltage and resistance measurements</li>
<li>DC Recorder output</li>
<li>55mm in diameter of measurable conductor</li>
<li>Sleep function</li>
<li>Data hold function</li>
<li>Approved for conformity to safety standards EN61010-1,EN61010-2-031, EN61010-2-032 (CAT. III 600 V, CAT. II 1000 V)</li>
</ul>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg"><img class="alignnone size-full wp-image-5776" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg" alt="" width="200" height="186" /></a></p>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2017/11/Yokogawa-CL-Clampmeter-Datasheet.pdf" rel="noopener"><span style="color: #0000ff;">Yokogawa CL Clampmeter Datasheet</span></a></h4>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-cl255-true-rms-acdc-2000a-clamp-meter/">Yokogawa CL255 True RMS AC/DC 2000A Clamp Meter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Yokogawa CL255 Clampmeter Specifications:</h3>
<table class="stripe table1">
<tbody>
<tr>
<th scope="row">Description</th>
<td>True RMS ACA, DCA, ACV, DCV</td>
</tr>
<tr>
<th scope="row">Method of detection</th>
<td>True RMS</td>
</tr>
<tr>
<th scope="row">Display</th>
<td>LCD (Digital display: 3999 counts)</td>
</tr>
<tr>
<th scope="row">DC Current Range</th>
<td>400/2000A</td>
</tr>
<tr>
<th scope="row">DC Current Resolution</th>
<td>0.1A</td>
</tr>
<tr>
<th scope="row">Response Time</th>
<td>Approx. 1 second (on DC current/voltage range)<br />
Approx. 2 seconds (AC current/voltage range, resistance range)</td>
</tr>
<tr>
<th scope="row">Range Switching</th>
<td>Auto-range</td>
</tr>
<tr>
<th scope="row">Operating temperature and humidity</th>
<td>0 &#8211; 40°C, 85% RH or less (no condensation)</td>
</tr>
<tr>
<th scope="row">Influence of external magnetic field</th>
<td>4A or less at 400 A/m</td>
</tr>
<tr>
<th scope="row">Influence of conductor position</th>
<td>±(1.5% rdg + 3 dgt) or less</td>
</tr>
<tr>
<th scope="row">Safety Standard</th>
<td>Conforms EN61010-1, EN61010-2-031, EN61010-2-032</td>
</tr>
<tr>
<th scope="row">Circuit voltage</th>
<td>1000 Vrms or less</td>
</tr>
<tr>
<th scope="row">Withstanding voltage</th>
<td>5.55 kV AC for one minute</td>
</tr>
<tr>
<th scope="row">Power Supply</th>
<td>6F22 (006P) 9V x 1<br />
6LR61 x 1</td>
</tr>
<tr>
<th scope="row">Battery Life</th>
<td>Approx. 15 hours (continuous)</td>
</tr>
<tr>
<th scope="row">Consumed current</th>
<td>Approx. 15 mA</td>
</tr>
<tr>
<th scope="row">Sleep Function</th>
<td>Automatically powered down in about 10 minutes after the last switch operation</td>
</tr>
<tr>
<th scope="row">Diameter of measurable conductor</th>
<td>55 mm at maximum</td>
</tr>
<tr>
<th scope="row">Dimensions</th>
<td>Approx. 105 (W) x 250 (H) x 49 (D) mm</td>
</tr>
<tr>
<th scope="row">Weight</th>
<td>Approx. 540 g</td>
</tr>
<tr>
<th scope="row">Accessories</th>
<td>Batteries, carrying case (93034)<br />
Output plug (98012)<br />
Test Lead (98011)<br />
User&#8217;s manual (IM CL250)</td>
</tr>
<tr>
<th scope="row">Peak Hold</th>
<td>On current / Voltage range</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-cl255-true-rms-acdc-2000a-clamp-meter/">Yokogawa CL255 True RMS AC/DC 2000A Clamp Meter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Yokogawa CL250 2000A AC/DC Clamp Meter</title>
		<link>https://rapid-tech.com.au/yokogawa-cl250-2000a-acdc-clamp-meter/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Fri, 03 Nov 2017 14:32:54 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=5781</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/10/Yokogawa-Logo-Medium.jpg"><img class="alignnone size-full wp-image-5623" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/Yokogawa-Logo-Medium.jpg" alt="" width="250" height="50" />                    </a><a target="_blank" href="https://mymeter.com.au/product/yokogawa-cl250-2000a-ac-dc-clamp-meter/" rel="noopener noreferrer"><img class="alignnone wp-image-5427 size-thumbnail" src="https://rapid-tech.com.au/wp-content/uploads/2017/08/Buy-Now-small-150x65.jpg" alt="" width="150" height="65" /></a></p>
<h3>Yokogawa CL250 Clamp Meter</h3>
<p>&#160;</p>
<ul>
<li>AC/DC current measurements with current ranges up to 2000A</li>
<li>AC/DC voltage and resistance measurements</li>
<li>DC output</li>
<li>55mm in diameter of measurable conductor</li>
<li>Mean value display</li>
<li>Sleep function</li>
<li>Data hold function</li>
<li>Approved for conformity to safety standards EN61010-1, EN61010-2-031, EN61010-2-032 (CAT. III 600 V, CAT. II 1000 V)</li>
</ul>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg"><img class="alignnone size-full wp-image-5776" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg" alt="" width="200" height="186" /></a></p>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="color: #0000ff;"><a href="https://rapid-tech.com.au/wp-content/uploads/2017/09/Yokogawa-CL-Clampmeter-Datasheet.pdf">Yokogawa CL Clampmeter Datasheet</a></span></h3>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-cl250-2000a-acdc-clamp-meter/">Yokogawa CL250 2000A AC/DC Clamp Meter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Yokogawa CL250 2000A AC/DC Clamp Meter measures ACA, DCA, ACV, DCV, OHM, Frequency. Temperature, Continuity Check for conductors up to 54 mm in diameter.</p>
<div class="col_Imag_container"> Yokogawa CL250 2000A AC/DC Clamp Meter Specifications:</div>
<table class="stripe table1">
<tbody>
<tr>
<th scope="row">Description</th>
<td>ACA, DCA, ACV, DCV, OHM, Freq. °C Continuity Check</td>
</tr>
<tr>
<th scope="row">Method of detection</th>
<td>Mean Value</td>
</tr>
<tr>
<th scope="row">Display</th>
<td>LCD (Digital display: 3999 counts)</td>
</tr>
<tr>
<th scope="row">DC Current Range</th>
<td>400/2000A</td>
</tr>
<tr>
<th scope="row">DC Current Resolution</th>
<td>0.1A</td>
</tr>
<tr>
<th scope="row">Response Time</th>
<td>Approx. 2 seconds</td>
</tr>
<tr>
<th scope="row">Range Switching</th>
<td>Auto-range (on resistance range)<br />
Manual-range (on current, voltage range)</td>
</tr>
<tr>
<th scope="row">Operating temperature and humidity</th>
<td>0 &#8211; 40°C, 85% RH or less (no condensation)</td>
</tr>
<tr>
<th scope="row">Influence of external magnetic field</th>
<td>4A or less at 400 A/m</td>
</tr>
<tr>
<th scope="row">Influence of conductor position</th>
<td>±(1.5% rdg + 3 dgt) or less</td>
</tr>
<tr>
<th scope="row">Safety Standard</th>
<td>Conforms EN61010-1, EN61010-2-031, EN61010-2-032</td>
</tr>
<tr>
<th scope="row">Circuit voltage</th>
<td>1000 Vrms or less</td>
</tr>
<tr>
<th scope="row">Withstanding voltage</th>
<td>5.55 kV AC for one minute</td>
</tr>
<tr>
<th scope="row">Power Supply</th>
<td>LR6 x 2<br />
R6P (SUM-3) x 2</td>
</tr>
<tr>
<th scope="row">Battery Life</th>
<td>Approx. 100 hours (continuous)</td>
</tr>
<tr>
<th scope="row">Consumed current</th>
<td>Approx. 9 mA</td>
</tr>
<tr>
<th scope="row">Sleep Function</th>
<td>Automatically powered down in about 10 minutes after the last switch operation</td>
</tr>
<tr>
<th scope="row">Diameter of measurable conductor</th>
<td>55 mm at maximum</td>
</tr>
<tr>
<th scope="row">Dimensions</th>
<td>Approx. 105 (W) x 250 (H) x 49 (D) mm</td>
</tr>
<tr>
<th scope="row">Weight</th>
<td>Approx. 530 g</td>
</tr>
<tr>
<th scope="row">Accessories</th>
<td>Batteries, carrying case (93034)<br />
Output plug (98012)<br />
Test Lead (98011)<br />
User&#8217;s manual (IM CL250)</td>
</tr>
<tr>
<th scope="row">Peak Hold</th>
<td>On all range</td>
</tr>
<tr>
<th scope="row">Max Hold</th>
<td>On current / Voltage range</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-cl250-2000a-acdc-clamp-meter/">Yokogawa CL250 2000A AC/DC Clamp Meter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Yokogawa CL320 Clamp-on Leakage Tester</title>
		<link>https://rapid-tech.com.au/yokogawa-cl320-clamp-leakage-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 19 Sep 2017 20:41:39 +0000</pubDate>
				<guid isPermaLink="false">http://rapid-tech.com.au/?post_type=product&#038;p=5483</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-5623" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/Yokogawa-Logo-Medium.jpg" alt="" width="250" height="50" /></p>
<p>&#160;</p>
<p><a target="_blank" href="https://mymeter.com.au/product/yokogawa-leakage-current-clamp-meter-20ma-to-200a/" rel="noopener"><img class="alignnone size-full wp-image-17843" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/BUY-NOW-form-My-Meter-e1620004827208.png" alt="Buy now form My Meter" width="220" height="55" /></a></p>
<p>The Yokogawa CL320 Clamp-on Leakage Tester offers an inexpensive dedicated Clamp-on meter that allows you to measure from 20mA AC to 200A AC with a wide frequency response range.</p>
<p>The Yokogawa CL320 is ideal for non-evasive electrical safety testing, measuring leakage current tests without powering down or disconnecting equipment – saving you time, without compromising on quality or safety.</p>
<p>&#160;</p>
<h3><img class="alignnone size-full wp-image-5149" src="http://rapid-tech.com.au/wp-content/uploads/2017/05/pdf_sml-1.png" alt="pdf_sml" width="40" height="40" />    <span style="text-decoration: underline;"><span style="color: #0000ff; text-decoration: underline;"><a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2017/09/Yokogawa-CL-Clampmeter-Datasheet.pdf" rel="noopener">Yokogawa CL Clampmeter Datasheet</a></span></span></h3>
<h3><a href="http://rapid-tech.com.au/wp-content/uploads/2017/05/pdf_sml-1.png"><img class="alignnone size-full wp-image-5149" src="http://rapid-tech.com.au/wp-content/uploads/2017/05/pdf_sml-1.png" alt="pdf_sml" width="40" height="40" /></a>    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2017/09/Yokogawa-CL320-User-Manual.pdf" rel="noopener">Yokogawa CL320 User Manual</a></span></span></h3>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg"><img class="alignnone size-full wp-image-5776" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg" alt="" width="200" height="186" /></a></p>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-cl320-clamp-leakage-tester/">Yokogawa CL320 Clamp-on Leakage Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<p><strong>Yokogawa CL320 Clamp-on Leakage Tester Features:</strong></p>
<ul>
<li>Leakage current measurement with current range from 20mA to 200A</li>
<li>Light weight and compact design</li>
<li>Manual range switching and auto power-off functions</li>
<li>24mm in diameter of measurable conductor</li>
<li>Mean value display</li>
<li>Auto power-off</li>
<li>Manual range switching</li>
<li>Approved for conformity to safety standards EN61010-1, EN61010-2-032(CAT. III 300 V)</li>
</ul>
<p><a href="http://rapid-tech.com.au/wp-content/uploads/2017/09/Yokogawa-CL320-Layout.jpg"><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-5490" src="http://rapid-tech.com.au/wp-content/uploads/2017/09/Yokogawa-CL320-Layout.jpg" alt="Yokogawa CL320 Layout" width="612" height="515" srcset="https://rapid-tech.com.au/wp-content/uploads/2017/09/Yokogawa-CL320-Layout.jpg 612w, https://rapid-tech.com.au/wp-content/uploads/2017/09/Yokogawa-CL320-Layout-300x252.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2017/09/Yokogawa-CL320-Layout-600x505.jpg 600w" sizes="(max-width: 612px) 100vw, 612px" /></a></p>
<h3></h3>
<h3>Yokogawa CL320 Clamp-on Leakage Tester Specifications:</h3>
<table id="Specifications">
<tbody>
<tr class="Table_Blue_Background_BLR">
<td class="Table_Blue_Background_BLR" colspan="2"><strong>Display</strong></td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Display</td>
<td class="Table_cell_outline_BR">LCD (Digital display: 1999 counts)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Current Range</td>
<td class="Table_cell_outline_BR">20/200mA,200A</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Current Resolution</td>
<td class="Table_cell_outline_BR">0.01mA</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Ac Frequency Characteristics</td>
<td class="Table_cell_outline_BR">40~400Hz</td>
</tr>
<tr class="Table_Blue_Background_BLR">
<td class="Table_Green_Background_BLR" colspan="2"><strong>Specific Accuracies</strong></td>
</tr>
<tr class="Table_Blue_Background_BLR">
<td class="Table_Blue_Background_BLR" colspan="2"><strong><em>WIDE(40～400Hz)</em></strong></td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Accuracy (20mA/200mA):</td>
<td class="Table_cell_outline_BR">2.0+4 (50/60Hz)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Accuracy 200A (0～100A):</td>
<td class="Table_cell_outline_BR">5.0+6 (40～400Hz)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Accuracy 200A (100.1～200A):</td>
<td class="Table_cell_outline_BR">5.0+4 (50/60Hz)</td>
</tr>
<tr class="Table_Blue_Background_BLR">
<td class="Table_Blue_Background_BLR" colspan="2"><strong><em>50/60Hz</em></strong></td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Accuracy (20mA/200mA):</td>
<td class="Table_cell_outline_BR">3.0+5 (50/60Hz)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">200A(0～100A)</td>
<td class="Table_cell_outline_BR">3.0+5 (50/60Hz)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">200A(100.1～200A)</td>
<td class="Table_cell_outline_BR">5.0+5 (50/60Hz)</td>
</tr>
<tr class="Table_Blue_Background_BLR">
<td class="Table_Blue_Background_BLR" colspan="2"><strong>General specifications</strong></td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Method of Detection</td>
<td class="Table_cell_outline_BR">Mean value</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Response Time</td>
<td class="Table_cell_outline_BR">Approx. 2 seconds</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Range Switching</td>
<td class="Table_cell_outline_BR">Manual-range</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Data Hold</td>
<td class="Table_cell_outline_BR">On all range</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Influence of external magnetic field</td>
<td class="Table_cell_outline_BR">10 mA or less in proximity to a 14.4 mm-dia conductor carrying 100A</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Influence of conductor position</td>
<td class="Table_cell_outline_BR">Within 5 dgt for 0 to 50A, or 2% for 50 to 200A (10 mm-dia conductor at inside the jaw)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Influence of Residual Current</td>
<td class="Table_cell_outline_BR">10 mA or less in proximity to a 10 mm-dia conductor carrying 50A</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Safety Standard</td>
<td class="Table_cell_outline_BR">Conforms EN61010-1, EN61010-2-032</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Circuit Voltage</td>
<td class="Table_cell_outline_BR">300Vrms or less</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Withstanding Voltage</td>
<td class="Table_cell_outline_BR">3.7kV AC for one minute</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Auto power-off</td>
<td class="Table_cell_outline_BR">Approx. 10 minutes</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Diameter of measurable<br />
conductor</td>
<td class="Table_cell_outline_BR">24mm at maximum</td>
</tr>
<tr>
<td class="Table_Green_Background_BLR" colspan="2"><strong>Environment</strong></td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Operating Temp.:</td>
<td class="Table_cell_outline_BR">0 – 40°C</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Relative Humidity:</td>
<td class="Table_cell_outline_BR">85% (non condensing)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Dimensions</td>
<td class="Table_cell_outline_BR">Approx. 60 (W) x 149 (H) x 26 (D) mm</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Weight</td>
<td class="Table_cell_outline_BR">Approx. 120 g</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Accessories</td>
<td class="Table_cell_outline_BR">Batteries, carrying case (93033)<br />
User’s manual (IM CL320)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Power Supply</td>
<td class="Table_cell_outline_BR">LR-44 x2(3V) or SR-44 x2</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Battery Life</td>
<td class="Table_cell_outline_BR">Approx. 100 hours (continuous)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Consumed Current</td>
<td class="Table_cell_outline_BR">Approx. 9 m</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-cl320-clamp-leakage-tester/">Yokogawa CL320 Clamp-on Leakage Tester</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Yokogawa CL220 Clamp-on AC/DC Current Clampmeter</title>
		<link>https://rapid-tech.com.au/yokogawa-cl220-clamp-acdc-current-clampmeter/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Mon, 21 Aug 2017 14:46:31 +0000</pubDate>
				<guid isPermaLink="false">http://rapid-tech.com.au/?post_type=product&#038;p=5388</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-5623" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/Yokogawa-Logo-Medium.jpg" alt="" width="250" height="50" /></p>
<p>&#160;</p>
<p><a target="_blank" href="https://mymeter.com.au/product/yokogawa-cl220-mini-acdc-300a-clamp-meter/" rel="noopener"><img class="alignnone size-full wp-image-17843" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/BUY-NOW-form-My-Meter-e1620004827208.png" alt="Buy now form My Meter" width="220" height="55" /></a></p>
<p>AC/DC current measurements with current ranges up to 300A<br />
24mm in diameter of measurable conductor<br />
Light weight &#38; compact design<br />
Mean value display<br />
Sleep function</p>
<h3></h3>
<h4><a href="http://rapid-tech.com.au/wp-content/uploads/2017/05/pdf_sml-1.png"><img class="alignnone size-full wp-image-5149" src="http://rapid-tech.com.au/wp-content/uploads/2017/05/pdf_sml-1.png" alt="pdf_sml" width="40" height="40" /></a>    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2017/08/Yokogawa-CL-and-300-Series-Clampmeter.pdf" rel="noopener">Yokogawa CL and 300 Series Clampmeter</a></span></span></h4>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg"><img class="alignnone size-full wp-image-5776" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg" alt="" width="200" height="186" /></a></p>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-cl220-clamp-acdc-current-clampmeter/">Yokogawa CL220 Clamp-on AC/DC Current Clampmeter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Yokogawa CL220 Clamp-on is an Average Responding AC/DC Current Clampmeter that has functions of AC/DC current measurement. It allows you to measure current ranges of 40A/300A fullscale. Able to measure on cables up to 24mm.</p>
<h4><strong>Yokogawa CL220 Specifications:</strong></h4>
<table class="data" border="1" cellspacing="0">
<tbody>
<tr>
<th scope="row">Description</th>
<td>AC/DC Mini Clamp-on</td>
</tr>
<tr>
<th scope="row">Method of detection</th>
<td>Mean Value</td>
</tr>
<tr>
<th scope="row">Display</th>
<td>LCD (Digital display: 3999 counts)</td>
</tr>
<tr>
<th scope="row">DC Current Range</th>
<td>40/300A</td>
</tr>
<tr>
<th scope="row">DC Current Resolution</th>
<td>0.01A</td>
</tr>
<tr>
<th scope="row">Response Time</th>
<td>Approx. 2 second</td>
</tr>
<tr>
<th scope="row">Range Switching</th>
<td>Auto-range</td>
</tr>
<tr>
<th scope="row">Data hold</th>
<td>On all range</td>
</tr>
<tr>
<th scope="row">Operating temperature and humidity</th>
<td>0 &#8211; 40°C, 90% RH or less (no condensation)</td>
</tr>
<tr>
<th scope="row">Influence of external magnetic field</th>
<td>1A or less at 400 A/m</td>
</tr>
<tr>
<th scope="row">Influence of conductor position</th>
<td>±(2% rdg + 5dgt) or less</td>
</tr>
<tr>
<th scope="row">Safety Standard</th>
<td>Conforms EN61010-1, EN61010-2-031, EN61010-2-032</td>
</tr>
<tr>
<th scope="row">Circuit voltage</th>
<td>300 Vrms or less</td>
</tr>
<tr>
<th scope="row">Withstanding voltage</th>
<td>3.7 kV AC for one minute</td>
</tr>
<tr>
<th scope="row">Power Supply</th>
<td>LR-44 x 2 (3V)<br />
SR-44 x 2</td>
</tr>
<tr>
<th scope="row">Battery Life</th>
<td>Approx. 11 hours (continuous)</td>
</tr>
<tr>
<th scope="row">Consumed current</th>
<td>Approx. 9 mA</td>
</tr>
<tr>
<th scope="row">Sleep Function</th>
<td>Automatically powered down in about 5 minutes after the last switch operation</td>
</tr>
<tr>
<th scope="row">Diameter of measurable conductor</th>
<td>24 mm at maximum</td>
</tr>
<tr>
<th scope="row">Dimensions</th>
<td>Approx. 59 (W) x 147 (H) x 25 (D) mm</td>
</tr>
<tr>
<th scope="row">Weight</th>
<td>Approx. 100 g</td>
</tr>
<tr>
<th scope="row">Accessories</th>
<td>Batteries, carrying case (93033)<br />
User&#8217;s manual (IM CL235)</td>
</tr>
</tbody>
</table>
<h4><strong>Yokogawa CL220 Additional Specification:</strong></h4>
<p>At 23°C±5°C, 75%RH or less<br />
Accuracy: ±( % rdg + dgt) = ±(% readout + value of least significant digit)</p>
<table class="data" style="height: 287px;" border="1" width="582" cellspacing="0">
<tbody>
<tr>
<th scope="col">Parameter</th>
<th scope="col">Reference</th>
<th scope="col">Accuracy</th>
</tr>
<tr>
<td rowspan="3">DC current</td>
<td>40A</td>
<td>1.0+4</td>
</tr>
<tr>
<td>300A(±20～±200A)</td>
<td>1.5+4</td>
</tr>
<tr>
<td>300A(±200～±300A)</td>
<td>3.0</td>
</tr>
<tr>
<td rowspan="6">AC current</td>
<td rowspan="2">40A</td>
<td>1.0+4 (50/60Hz)</td>
</tr>
<tr>
<td>2.5+4 (20～1kHz)</td>
</tr>
<tr>
<td rowspan="2">300A(20～200A)</td>
<td>1.5+4 (50/60Hz)</td>
</tr>
<tr>
<td>2.5+4 (20～1kHz)</td>
</tr>
<tr>
<td rowspan="2">300A(200～300A)</td>
<td>3.5 (50/60Hz)</td>
</tr>
<tr>
<td>4.0 (20～1kHz)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-cl220-clamp-acdc-current-clampmeter/">Yokogawa CL220 Clamp-on AC/DC Current Clampmeter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Yokogawa CL345 40mA/400A Leakage Current Clamp-On Meters</title>
		<link>https://rapid-tech.com.au/yokogawa-cl345-40ma400a-leakage-current-clamp-on-meters/</link>
					<comments>https://rapid-tech.com.au/yokogawa-cl345-40ma400a-leakage-current-clamp-on-meters/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Sun, 14 Feb 2016 15:12:23 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/yokogawa-cl345-40ma400a-leakage-current-clamp-on-meters/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-33" src="http://rapid-tech.com.au/wp-content/uploads/2015/12/Yokogawa_logo_sml.jpg" alt="Yokogawa_logo_sml" width="110" height="20" /></p>
<p><b>Clamp-On Tester for AC Leakage Current Measurements </b></p>
<p><span style="font-size: medium;">Features</span></p>
<ul>
<li>True RMS display.</li>
<li>Leakage current measurement with current range from 40mA to 400A.</li>
<li>40mm in diameter of measurable conductor.</li>
<li>Auto power off.</li>
<li>Manual range switching.</li>
<li>Approved for conformity to safety standards EN61010-1, EN61010-2-032<br />
(CAT III 300V)</li>
</ul>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg"><img class="alignnone size-full wp-image-5776" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg" alt="" width="200" height="186" /></a></p>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-cl345-40ma400a-leakage-current-clamp-on-meters/">Yokogawa CL345 40mA/400A Leakage Current Clamp-On Meters</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Yokogawa CL345 is a true RMS Clamp-on tester that provides an easy-to read, 3999 count display. The CL345 is able to measure current with noise or harmonics from 40 mA to 400 AAC .  It is an accurate and robust dedicated leakage meter with a mid-size clamp diameter  that accepts conductors up to 44 mm diameter.</p>
<table border="0" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="2"><span style="font-size: medium;">Yokogawa CL345 Specifications</span></td>
</tr>
<tr>
<td colspan="2">
<table border="1" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td bgcolor="#b4cdcd" width="174"><b>Parameter</b></td>
<td bgcolor="#c0d9d9" width="156"><b>Reference</b></td>
<td colspan="2" bgcolor="#c0d9d9" width="270">
<p align="center"><b>Accuracy</b></p>
</td>
</tr>
<tr>
<td rowspan="4" bgcolor="#b4cdcd" width="174">AC Current</td>
<td bgcolor="#c0d9d9" width="156"></td>
<td align="left" bgcolor="#c0d9d9" width="146">Wide (20Hz to 1kHz)</td>
<td align="left" bgcolor="#c0d9d9" width="124">50/60Hz</td>
</tr>
<tr>
<td bgcolor="#c0d9d9" width="156">40mA/400mA</td>
<td bgcolor="#c0d9d9" width="146">2.5+10 (20 to 1kHz)</td>
<td bgcolor="#c0d9d9" width="124">1.0+5 (50/60Hz)</td>
</tr>
<tr>
<td bgcolor="#c0d9d9" width="156">400A (0 to 350A)</td>
<td bgcolor="#c0d9d9" width="146">2.5+10 (40 to 1kHz)</td>
<td bgcolor="#c0d9d9" width="124">1.0+5 (50/60Hz)</td>
</tr>
<tr>
<td bgcolor="#c0d9d9" width="156">400A (350 to 400A)</td>
<td bgcolor="#c0d9d9" width="146">5.0 (40 to 1kHz)</td>
<td bgcolor="#c0d9d9" width="124">2.0 (50/60Hz)</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2"><b>At 23°C ±5°C, 75% RH or less<br />
Accuracy: ±(% rdg + dgt) = ±(% readout + value of least significant digit)</b></td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2"><span style="font-size: medium;">General Specifications</span></td>
</tr>
<tr>
<td colspan="2">
<table border="1" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td bgcolor="#b4cdcd" width="181"><b>Parameter</b></td>
<td bgcolor="#c0d9d9" width="415">
<p align="center"><b>Specification</b></p>
</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Method of detection</td>
<td bgcolor="#c0d9d9" width="415">True RMS</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Display</td>
<td bgcolor="#c0d9d9" width="415">LCD (Digital display:3999 counts)</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Response Time</td>
<td bgcolor="#c0d9d9" width="415">Approx. 2 seconds</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Range Switching</td>
<td bgcolor="#c0d9d9" width="415">Manual range</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Data Hold</td>
<td bgcolor="#c0d9d9" width="415">On all ranges</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Peak Hold</td>
<td bgcolor="#c0d9d9" width="415">On all ranges</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Ambient Temperature and Humidity</td>
<td bgcolor="#c0d9d9" width="415">0 to 40<span style="font-family: Verdana,Arial,Helvetica;">°C<br />
85% RH or less (no condensation)</span></td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Temperature Coefficient</td>
<td bgcolor="#c0d9d9" width="415">N/A</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Influence of External Magnetic Field</td>
<td bgcolor="#c0d9d9" width="415">10mA or less in proximity to a 15mm-dia conductor carrying 100Amps.</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Influence of Conductor Position</td>
<td bgcolor="#c0d9d9" width="415">40/400mA range: Within 5dgts at every part inside the jaw (400A range).<br />
0 to 250A range: Within <span style="font-family: Verdana,Arial,Helvetica;"> ±0.5% rdg ±5dgt at every part inside the jaw section.</span></td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Influence of residual current</td>
<td bgcolor="#c0d9d9" width="415">12mA or less in proximity to a 10mm-dia conductor carrying 100Amps.</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Safety Standard</td>
<td bgcolor="#c0d9d9" width="415">EN61010-1, EN61010-2-032 (CAT III 300V)</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Circuit Voltage</td>
<td bgcolor="#c0d9d9" width="415">300Vrms or less</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Withstanding Voltage</td>
<td bgcolor="#c0d9d9" width="415">3.7kV AC for one minute</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2">
<table border="1" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td bgcolor="#b4cdcd" width="181">Power Supply</td>
<td bgcolor="#c0d9d9" width="415">R0-3(UM-4) x 2 or LR03 x 2</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Battery Life</td>
<td bgcolor="#c0d9d9" width="415">Approx. 40 hours (continuous)</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Consumed Current</td>
<td bgcolor="#c0d9d9" width="415">Approx. 13mA</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Auto Power Off</td>
<td bgcolor="#c0d9d9" width="415">Approx. 10 minutes</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Diameter of Measurable Conductor</td>
<td bgcolor="#c0d9d9" width="415">40mm maximum</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Dimensions</td>
<td bgcolor="#c0d9d9" width="415">Approx. 81mm (W) x 185mm (H) x 40mm (D)</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Weight</td>
<td bgcolor="#c0d9d9" width="415">Approx. 270g</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Accessories</td>
<td bgcolor="#c0d9d9" width="415">User&#8217;s manual (IM CL345), Batteries &amp; Carrying Case (93030)</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2"><span style="font-size: medium;">Ordering Information</span></td>
</tr>
<tr>
<td colspan="2">
<table border="1" width="100%" cellpadding="0" bgcolor="#f9f8ed">
<tbody>
<tr>
<td valign="top" bgcolor="#b4cdcd" width="237">Yokogawa CL345</td>
<td bgcolor="#c0d9d9">Clamp-On Tester for AC Leakage Current. Includes: User&#8217;s manual, batteries, and carrying case</td>
</tr>
</tbody>
</table>
</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-cl345-40ma400a-leakage-current-clamp-on-meters/">Yokogawa CL345 40mA/400A Leakage Current Clamp-On Meters</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/yokogawa-cl345-40ma400a-leakage-current-clamp-on-meters/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Yokogawa CL360 200mA/1000A Leakage Current Clamp-On Meters</title>
		<link>https://rapid-tech.com.au/yokogawa-cl360-200ma1000a-leakage-current-clamp-on-meters/</link>
					<comments>https://rapid-tech.com.au/yokogawa-cl360-200ma1000a-leakage-current-clamp-on-meters/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Sun, 14 Feb 2016 15:12:23 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/yokogawa-cl360-200ma1000a-leakage-current-clamp-on-meters/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-5623" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/Yokogawa-Logo-Medium.jpg" alt="" width="250" height="50" /></p>
<p>&#160;</p>
<p><a target="_blank" href="https://mymeter.com.au/product/yokogawa-cl360-clamp-on-tester-for-ac-leakage-current-measurements/" rel="noopener"><img class="alignnone size-full wp-image-17843" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/BUY-NOW-form-My-Meter-e1620004827208.png" alt="Buy now form My Meter" width="220" height="55" /></a></p>
<p>The Yokogawa CL360 Clamp-on meter features a large clamp that can measure conductors up to 69 mm in diameter and a leakage current range from 200mA and a maximum current range of 1000AAC, ideal for regular current measurement and high resolution for leakage detection.</p>
<ul>
<li>Leakage current measurement with current range from 200mA to 1000A.</li>
<li>AC and DC output.</li>
<li>68mm in diameter of measurable conductor.</li>
<li>Mean value display.</li>
<li>Manual range switching.</li>
<li>Approved for conformity to safety standards EN61010-1, EN61010-2-032<br />
(CAT III 300V) (CAT II 600V)</li>
</ul>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg"><img class="alignnone size-full wp-image-5776" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg" alt="" width="200" height="186" /></a></p>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-cl360-200ma1000a-leakage-current-clamp-on-meters/">Yokogawa CL360 200mA/1000A Leakage Current Clamp-On Meters</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Yokogawa CL360 Features:</strong></p>
<ul>
<li>Leakage current measurement with current range from 200mA to 1000A</li>
<li>Method of detection Mean Value</li>
<li>Display LCD (Digital display: 1999 counts)</li>
<li>Response Time Approx. 1 second</li>
<li>Range Switching Manual-range</li>
<li>Data hold On all range</li>
<li>Operating temperature and humidity -10 – 50°C , 80% RH or less (no condensation)</li>
<li>Safety Standard Conforms EN61010-1, EN61010-2-032</li>
<li>Circuit voltage 300 Vrms or less</li>
<li>Withstanding voltage 3.7 kV AC for one minute</li>
<li>Power Supply 6 LR61 x 1, 6F22 (006P) 9V x 1</li>
<li>Battery Life Approx. 60 hours (continuous)</li>
<li>Consumed current Approx. 5 mA</li>
<li>Diameter of measurable conductor 68 mm at maximum</li>
<li>Dimensions Approx. 129 (W) x 248 (H) x 55 (D) mm</li>
<li>Weight Approx. 570 g</li>
<li>Accessories Batteries, carrying case (93031), User’s manual</li>
<li>Peak Hold On all range</li>
</ul>
<h4><strong>Yokogawa CL360 Specifications:</strong></h4>
<table border="1" width="539" cellspacing="0" cellpadding="2">
<tbody>
<tr>
<td rowspan="2" align="center" bgcolor="#caccdb"><span style="font-size: small;"><b>Parameter</b></span></td>
<td rowspan="2" align="center" bgcolor="#caccdb"><span style="font-size: small;"><b>Reference</b></span></td>
<td colspan="2" align="center" bgcolor="#caccdb"><span style="font-size: small;"><b>Accuracy</b></span></td>
</tr>
<tr>
<td align="center" bgcolor="#caccdb" width="107"><span style="font-size: small;"><b>WIDE(40~1kHz)</b></span></td>
<td align="center" bgcolor="#caccdb" width="111"><span style="font-size: small;"><b>50/60Hz</b></span></td>
</tr>
<tr>
<td rowspan="4" align="center" bgcolor="#caccdb" width="125"><span style="font-size: small;"><b>AC Current </b></span></td>
<td align="center" bgcolor="#efefef" width="180"><span style="font-size: small;">20mA/2A/20A</span></td>
<td align="center" bgcolor="#efefef" width="115"><span style="font-size: small;">1.0+2 (50/60Hz) 3.0+2 (40~1kHz)</span></td>
<td align="center" bgcolor="#efefef" width="111"><span style="font-size: small;">1.5+2</span></td>
</tr>
<tr>
<td align="center" bgcolor="#efefef" width="180"><span style="font-size: small;">200A</span></td>
<td align="center" bgcolor="#efefef" width="115"><span style="font-size: small;">1.5+2 (50/60Hz) 3.5+2 (40~1kHz)</span></td>
<td align="center" bgcolor="#efefef" width="111"><span style="font-size: small;">2.0+2</span></td>
</tr>
<tr>
<td align="center" bgcolor="#efefef" width="180"><span style="font-size: small;">1000A(0~500A)</span></td>
<td align="center" bgcolor="#efefef" width="115"><span style="font-size: small;">1.5+2 (50/60Hz) 3.5+2 (40~1kHz)</span></td>
<td align="center" bgcolor="#efefef" width="111"><span style="font-size: small;">2.0+2</span></td>
</tr>
<tr>
<td align="center" bgcolor="#efefef" width="180"><span style="font-size: small;">1000A(501~1000A)</span></td>
<td align="center" bgcolor="#efefef" width="115"><span style="font-size: small;">5.0 (50/60Hz) 10.0 (40~1kHz)</span></td>
<td align="center" bgcolor="#efefef" width="111"><span style="font-size: small;">5.5</span></td>
</tr>
<tr>
<td rowspan="4" align="center" bgcolor="#caccdb" width="115"><span style="font-size: small;"><b>AC Output </b></span></td>
<td align="center" bgcolor="#efefef" width="180"><span style="font-size: small;">20mA/2A/20A(0~200mV)</span></td>
<td align="center" bgcolor="#efefef" width="115"><span style="font-size: small;">2.0</span></td>
<td align="center" bgcolor="#efefef" width="111"><span style="font-size: small;">2.0</span></td>
</tr>
<tr>
<td align="center" bgcolor="#efefef" width="180"><span style="font-size: small;">200A(0~200mV)</span></td>
<td align="center" bgcolor="#efefef" width="115"><span style="font-size: small;">2.5</span></td>
<td align="center" bgcolor="#efefef" width="111"><span style="font-size: small;">2.5</span></td>
</tr>
<tr>
<td align="center" bgcolor="#efefef" width="180"><span style="font-size: small;">1000A(0~50mV/0~500A)</span></td>
<td align="center" bgcolor="#efefef" width="115"><span style="font-size: small;">3.0</span></td>
<td align="center" bgcolor="#efefef" width="110"><span style="font-size: small;">3.0</span></td>
</tr>
<tr>
<td align="center" bgcolor="#efefef" width="180"><span style="font-size: small;">1000A(50~100mV/501~1000A)</span></td>
<td align="center" bgcolor="#efefef" width="115"><span style="font-size: small;">5.0</span></td>
<td align="center" bgcolor="#efefef" width="111"><span style="font-size: small;">5.0</span></td>
</tr>
<tr>
<td rowspan="4" align="center" bgcolor="#caccdb" width="115"><span style="font-size: small;"><b>DC Output </b></span></td>
<td align="center" bgcolor="#efefef" width="180"><span style="font-size: small;">20mA/2A/20A(0~200mV)</span></td>
<td align="center" bgcolor="#efefef" width="115"><span style="font-size: small;">3.0</span></td>
<td align="center" bgcolor="#efefef" width="111"><span style="font-size: small;">3.5</span></td>
</tr>
<tr>
<td align="center" bgcolor="#efefef" width="180"><span style="font-size: small;">200A(0~200mV)</span></td>
<td align="center" bgcolor="#efefef" width="115"><span style="font-size: small;">3.5</span></td>
<td align="center" bgcolor="#efefef" width="111"><span style="font-size: small;">4.0</span></td>
</tr>
<tr>
<td align="center" bgcolor="#efefef" width="180"><span style="font-size: small;">1000A(0~50mV/0~500A)</span></td>
<td align="center" bgcolor="#efefef" width="115"><span style="font-size: small;">5.0</span></td>
<td align="center" bgcolor="#efefef" width="110"><span style="font-size: small;">5.5</span></td>
</tr>
<tr>
<td align="center" bgcolor="#efefef" width="180"><span style="font-size: small;">1000A(50~100mV/501~1000A)</span></td>
<td align="center" bgcolor="#efefef" width="115"><span style="font-size: small;">7.0</span></td>
<td align="center" bgcolor="#efefef" width="111"><span style="font-size: small;">7.5</span></td>
</tr>
<tr>
<td colspan="4" align="center" bgcolor="#ffffff">
<ul>
<li>
<p align="left"><b>General Specifications</b></p>
</li>
</ul>
</td>
</tr>
<tr>
<td align="center" bgcolor="#caccdb"><span style="font-size: small;"><b>Parameter</b></span></td>
<td colspan="3" align="center" bgcolor="#caccdb"><span style="font-size: small;"><b>Specification</b></span></td>
</tr>
<tr>
<td align="center" bgcolor="#caccdb"><span style="font-size: small;"><b>Method of Detection</b></span></td>
<td colspan="3" align="center" bgcolor="#efefef"><span style="font-size: small;">Mean Value</span></td>
</tr>
<tr>
<td align="center" bgcolor="#caccdb"><span style="font-size: small;"><b>Diameter of Measurable conductor</b></span></td>
<td colspan="3" align="center" bgcolor="#efefef"><span style="font-size: small;">Ø68MM at maximum</span></td>
</tr>
<tr>
<td align="center" bgcolor="#caccdb"><span style="font-size: small;"><b>Display</b></span></td>
<td colspan="3" align="center" bgcolor="#efefef"><span style="font-size: small;">LCD (Digital Display: 1999 Counts)</span></td>
</tr>
<tr>
<td align="center" bgcolor="#caccdb"><span style="font-size: small;"><b>Response Time (Approx.)</b></span></td>
<td colspan="3" align="center" bgcolor="#efefef"><span style="font-size: small;">1 Second</span></td>
</tr>
<tr>
<td align="center" bgcolor="#caccdb"><span style="font-size: small;"><b>Range Switching</b></span></td>
<td colspan="3" align="center" bgcolor="#efefef"><span style="font-size: small;">Manual-Range</span></td>
</tr>
<tr>
<td align="center" bgcolor="#caccdb"><span style="font-size: small;"><b>Data Hold</b></span></td>
<td colspan="3" align="center" bgcolor="#efefef"><span style="font-size: small;">On All range</span></td>
</tr>
<tr>
<td align="center" bgcolor="#caccdb"><span style="font-size: small;"><b>Peak Hold</b></span></td>
<td colspan="3" align="center" bgcolor="#efefef"><span style="font-size: small;">On All range</span></td>
</tr>
<tr>
<td align="center" bgcolor="#caccdb"><span style="font-size: small;"><b>Ambient Temperature and Humidity</b></span></td>
<td colspan="3" align="center" bgcolor="#efefef"><span style="font-size: small;">-10-50˚C, 80% RH or less (no condensation)</span></td>
</tr>
<tr>
<td align="center" bgcolor="#caccdb"><span style="font-size: small;"><b>Influence of external Magnetic Field</b></span></td>
<td colspan="3" align="center" bgcolor="#efefef"><span style="font-size: small;">15mA or less  in proximity to a 10-Dia conductor carrying 100A</span></td>
</tr>
<tr>
<td align="center" bgcolor="#caccdb"><span style="font-size: small;"><b>Influence of Conductor Position</b></span></td>
<td colspan="3" align="center" bgcolor="#efefef"><span style="font-size: small;">2% or less</span></td>
</tr>
<tr>
<td align="center" bgcolor="#caccdb"><span style="font-size: small;"><b>Influence of Residual Current</b></span></td>
<td colspan="3" align="center" bgcolor="#efefef"><span style="font-size: small;">10mA or less  in proximity to a 10-Dia conductor carrying 100A</span></td>
</tr>
<tr>
<td align="center" bgcolor="#caccdb"><b><span style="font-size: small;">Circuit Voltage</span></b></td>
<td colspan="3" align="center" bgcolor="#efefef"><span style="font-size: small;">300Vrms or less</span></td>
</tr>
<tr>
<td align="center" bgcolor="#caccdb"><span style="font-size: small;"><b>Withstanding Voltage</b></span></td>
<td colspan="3" align="center" bgcolor="#efefef"><span style="font-size: small;">3.7kV AC for one minute</span></td>
</tr>
<tr>
<td align="center" bgcolor="#caccdb"><span style="font-size: small;"><b>Power Supply</b></span></td>
<td colspan="3" align="center" bgcolor="#efefef"><span style="font-size: small;"> 6F22(006P)9V x1 or 6LR61 x1</span></td>
</tr>
<tr>
<td align="center" bgcolor="#caccdb"><span style="font-size: small;"><b>Battery Life</b></span></td>
<td colspan="3" align="center" bgcolor="#efefef"><span style="font-size: small;">Approx. 60 hours (continuous)</span></td>
</tr>
<tr>
<td align="center" bgcolor="#caccdb"><span style="font-size: small;"><b>Consumed Current</b></span></td>
<td colspan="3" align="center" bgcolor="#efefef"><span style="font-size: small;">Approx. 5mA</span></td>
</tr>
<tr>
<td align="center" bgcolor="#caccdb"><span style="font-size: small;"><b>Auto Power-off</b></span></td>
<td colspan="3" align="center" bgcolor="#efefef"><span style="font-size: small;">&#8211;</span></td>
</tr>
<tr>
<td align="center" bgcolor="#caccdb"><span style="font-size: small;"><b>Dimensions</b></span></td>
<td colspan="3" align="center" bgcolor="#efefef"><span style="font-size: small;">Approx. 129(W)x248(H)x55(D)mm</span></td>
</tr>
<tr>
<td align="center" bgcolor="#caccdb"><span style="font-size: small;"><b>Weight</b></span></td>
<td colspan="3" align="center" bgcolor="#efefef"><span style="font-size: small;">Approx. 570g</span></td>
</tr>
<tr>
<td align="center" bgcolor="#caccdb"><span style="font-size: small;"><b>AC/ DC Output Option</b></span></td>
<td colspan="3" align="center" bgcolor="#efefef"><span style="font-size: small;">Included</span></td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-cl360-200ma1000a-leakage-current-clamp-on-meters/">Yokogawa CL360 200mA/1000A Leakage Current Clamp-On Meters</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/yokogawa-cl360-200ma1000a-leakage-current-clamp-on-meters/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Yokogawa 30031A AC Leakage Current Clamp</title>
		<link>https://rapid-tech.com.au/yokogawa-30031a-1ma60a-leakage-current-clamp-on-meters/</link>
					<comments>https://rapid-tech.com.au/yokogawa-30031a-1ma60a-leakage-current-clamp-on-meters/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Sun, 14 Feb 2016 15:12:23 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/yokogawa-30031a-1ma60a-leakage-current-clamp-on-meters/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-5623" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/Yokogawa-Logo-Medium.jpg" alt="" width="250" height="50" /></p>
<p>&#160;</p>
<p><a target="_blank" href="https://mymeter.com.au/product/yokogawa-30031a-leakage-clamp-on-tester/" rel="noopener"><img class="alignnone size-full wp-image-17843" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/BUY-NOW-form-My-Meter-e1620004827208.png" alt="Buy now form My Meter" width="220" height="55" /></a></p>
<p>The Yokogawa 30031A AC leakage clamp-on tester can measure leakage currents of 1 mA. This can be useful for checking the insulation of low-voltage circuits and electrical components.</p>
<p>The Yokogawa 30031A leakage clamp-on tester can also measure a broad range of currents from leakage currents (at a resolution of 0.001 mA) to load currents up to 60 A. Typical influence (on the current value of an adjacent cable) from an external magnetic field is 0.0005%. Designed to withstand more than 50,000 opening/closing events, the Yokogawa 30031A leakage clamp-on tester is very durable.</p>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg"><img class="alignnone size-full wp-image-5776" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg" alt="" width="200" height="186" /></a></p>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-30031a-1ma60a-leakage-current-clamp-on-meters/">Yokogawa 30031A AC Leakage Current Clamp</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4>Feature of YOKOGAWA 30031A AC Leakage Clamp-On Tester.</h4>
<p>•3200 count LCD display<br />
•Mean value display<br />
•Exclusive model for Leakage current measurement with current ranges from 3mA to 60A<br />
•Resolution of 0.001mA at 3mA range<br />
•Can measure a broad range of currents from leakage currents (at a resolution of 0.001 mA) to load currents up to 60 A.<br />
•Can measure leakage currents of 1 mA<br />
•Approved for conformity to safety standards EN 61010-1 and EN 61010-2-032 (CAT III 300V, pollution degree2)</p>
<p><strong>Parameter Reference</strong><br />
AC Current 3/30mA, 30/60A<br />
Frequency Characteristics 50/60Hz<br />
Accuracy 50/60Hz 1.0+5 (0~30mA) 1.0+5 (0 ~ 50A) 5.0+5 (50/60Hz)</p>
<p><strong>Yokogawa 30031A General Specifications</strong></p>
<p>Parameter Specification<br />
Method of Detection Mean Value<br />
Diameter of Measurable conductor Ø40MM at maximum<br />
Display LCD Digital Display: 3200 Counts<br />
Bar-graph Display: 32 Segments<br />
Measurement Cycle Digital Display: 2 times/Seconds<br />
Bar-Graph Display: 12 times/second<br />
Range Switching Auto-Range<br />
Data Hold On All range<br />
Ambient Temperature and Humidity 0-50˚C, 85% RH or less (no condensation)<br />
Temperature coefficient 0.05% of range/°C or less (within the ranges of 0-18°C and 25-50°C for measurement of 0-50A)<br />
Influence of external Magnetic Field 0.0005% typical*1 (on current value of adjacent cable)<br />
Influence of Conductor Position Within Accuracy<br />
Circuit Voltage 300Vrms or less<br />
Withstanding Voltage 3.7kV AC for one minute<br />
Power Supply CR2032 (coin-shaped) 3V x1<br />
Battery Life Approx. 90 hours (continuous use)<br />
Auto Power-off Approx. 10 Minutes<br />
Dimensions Approx. 70(W)x176(H)x25(D)mm<br />
Weight Approx. 200g</p>
<table border="0" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="2"><span style="font-size: medium;">Yokogawa 30031A Specifications (AC current measurement</span><span style="font-size: medium;">)</span></td>
</tr>
<tr>
<td colspan="2">
<div align="center">
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td align="center" bgcolor="#b4cdcd" width="137"><b>Range</b></td>
<td align="center" bgcolor="#b4cdcd" width="138"><b>Resolution</b></td>
<td align="center" bgcolor="#b4cdcd" width="245"><b>Accuracy</b></td>
<td align="center" bgcolor="#b4cdcd" width="223"><b>Maximum Allowable Current</b></td>
</tr>
<tr>
<td align="center" bgcolor="#c0d9d9" width="137">3mA</td>
<td align="center" bgcolor="#c0d9d9" width="138">0.001mA</td>
<td align="center" bgcolor="#c0d9d9" width="245">0.010&lt;1&lt;32.70mA: 1.0% + 5 digits</td>
<td align="center" bgcolor="#c0d9d9" width="223">3.270mA</td>
</tr>
<tr>
<td align="center" bgcolor="#c0d9d9" width="137">30mA</td>
<td align="center" bgcolor="#c0d9d9" width="138">0.01mA</td>
<td align="center" bgcolor="#c0d9d9" width="245">0.010&lt;1&lt;32.70mA: 1.0% + 5 digits</td>
<td align="center" bgcolor="#c0d9d9" width="223">32.70mA</td>
</tr>
<tr>
<td align="center" bgcolor="#c0d9d9" width="137">30A</td>
<td align="center" bgcolor="#c0d9d9" width="138">0.01A</td>
<td align="center" bgcolor="#c0d9d9" width="245">0.05&lt;1&lt;50.0A: 1.0% + 5 digits</td>
<td align="center" bgcolor="#c0d9d9" width="223">32.70A</td>
</tr>
<tr>
<td align="center" bgcolor="#c0d9d9" width="137">60A</td>
<td align="center" bgcolor="#c0d9d9" width="138">0.1A</td>
<td align="center" bgcolor="#c0d9d9" width="245">50.0&lt;1&lt;60.6A: 5.0% + 5 digits</td>
<td align="center" bgcolor="#c0d9d9" width="223">60.6A</td>
</tr>
</tbody>
</table>
</div>
</td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2"><span style="font-size: medium;"> Specifications (AC current measurements for Model 30032A)</span></td>
</tr>
<tr>
<td colspan="2">
<div align="center">
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td align="center" bgcolor="#b4cdcd" width="137"><span style="color: #000080;"><b>Range</b></span></td>
<td align="center" bgcolor="#b4cdcd" width="138"><span style="color: #000080;"><b>Resolution</b></span></td>
<td align="center" bgcolor="#b4cdcd" width="245"><span style="color: #000080;"><b>Accuracy</b></span></td>
<td align="center" bgcolor="#b4cdcd" width="223"><span style="color: #000080;"><b>Maximum Allowable Current</b></span></td>
</tr>
<tr>
<td align="center" bgcolor="#c0d9d9" width="137"><span style="color: #000080;"> 3mA</span></td>
<td align="center" bgcolor="#c0d9d9" width="138"><span style="color: #000080;"> 0.001mA</span></td>
<td align="center" bgcolor="#c0d9d9" width="245"><span style="color: #000080;"> 0.010&lt;1&lt;32.70mA: 1.5% + 5 digits</span></td>
<td align="center" bgcolor="#c0d9d9" width="223"><span style="color: #000080;"> 3.270mA</span></td>
</tr>
<tr>
<td align="center" bgcolor="#c0d9d9" width="137"><span style="color: #000080;"> 30mA</span></td>
<td align="center" bgcolor="#c0d9d9" width="138"><span style="color: #000080;"> 0.01mA</span></td>
<td align="center" bgcolor="#c0d9d9" width="245"><span style="color: #000080;"> 0.010&lt;1&lt;32.70mA: 1.5% + 5 digits</span></td>
<td align="center" bgcolor="#c0d9d9" width="223"><span style="color: #000080;"> 32.70mA</span></td>
</tr>
<tr>
<td align="center" bgcolor="#c0d9d9" width="137"><span style="color: #000080;"> 30A</span></td>
<td align="center" bgcolor="#c0d9d9" width="138"><span style="color: #000080;"> 0.01A</span></td>
<td align="center" bgcolor="#c0d9d9" width="245"><span style="color: #000080;"> 0.05&lt;1&lt;50.0A: 1.5% + 5 digits</span></td>
<td align="center" bgcolor="#c0d9d9" width="223"><span style="color: #000080;"> 32.70A</span></td>
</tr>
<tr>
<td align="center" bgcolor="#c0d9d9" width="137"><span style="color: #000080;"> 60A</span></td>
<td align="center" bgcolor="#c0d9d9" width="138"><span style="color: #000080;"> 0.1A</span></td>
<td align="center" bgcolor="#c0d9d9" width="245"><span style="color: #000080;"> 50.0&lt;1&lt;60.6A: 5.5% + 5 digits</span></td>
<td align="center" bgcolor="#c0d9d9" width="223"><span style="color: #000080;"> 60.6A</span></td>
</tr>
</tbody>
</table>
</div>
</td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2">
<ul>
<li><b>Zero Correction:</b><br />
3mA Range: displays 0.000mA (zero) when 0.010mA &lt;1<br />
30A  Range: displays 0.00A (zero) when 0.05A&lt;1</li>
<li><b>Filter specification (for Model 30032A only)</b><br />
Amplitude ratio at 100Hz: -38dB (1.26%) or less (typical: -41dB)<br />
Amplitude ratio at 120Hz: -53dB (0.22%) or less (typical: -56dB)</li>
</ul>
</td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2"><span style="font-size: medium;">Yokogawa 30031A General Specifications</span></td>
</tr>
<tr>
<td colspan="2">
<table border="1" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td align="center" bgcolor="#b4cdcd" width="181">
<p align="left"><b>Parameter</b></p>
</td>
<td align="center" bgcolor="#c0d9d9" width="415"><b>Specification</b></td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Method of detection</td>
<td bgcolor="#c0d9d9" width="415">Mean Value Detection and RMS-Value Calibration</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Display</td>
<td bgcolor="#c0d9d9" width="415">LCD (Digital display:3200 counts)<br />
LCD (Bar-graph display: 32 segments)</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Range Switching</td>
<td bgcolor="#c0d9d9" width="415">Auto or manual range selection</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Data Hold</td>
<td bgcolor="#c0d9d9" width="415">On all ranges</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Ambient Temperature and Humidity</td>
<td bgcolor="#c0d9d9" width="415">0 to 50<span style="font-family: Verdana,Arial,Helvetica;">°C<br />
80% RH or less (no condensation)</span></td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Temperature Coefficient</td>
<td bgcolor="#c0d9d9" width="415">The following values must be added in the temperature range of either 30031A or 310032A<br />
0 to 18<span style="font-family: Verdana;">°C or 28 to 50°<br />
0&lt;1&lt;50.0A: ±(0.08% of reading/°C + 0.5 digits/°C)<br />
50.0&lt;1&lt;60.6A: ±(0.3% of reading/°C + 0.5 digits/°C)</span></td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Influence of External Magnetic Field</td>
<td bgcolor="#c0d9d9" width="415">0.0005% typical 1 (on current value of adjacent cable or wires)</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Safety Standard</td>
<td bgcolor="#c0d9d9" width="415">EN61010-1, EN61010-2-032 (CAT III 300V)</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Circuit Voltage</td>
<td bgcolor="#c0d9d9" width="415">300Vrms or less</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Withstanding Voltage</td>
<td bgcolor="#c0d9d9" width="415">3.7kV AC for one minute</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2">
<table border="1" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td bgcolor="#b4cdcd" width="181">Power Supply</td>
<td bgcolor="#c0d9d9" width="415">One CR2032 (Coin-shaped) 3V battery</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Battery Life</td>
<td bgcolor="#c0d9d9" width="415">Approx. 90 hours (continuous)</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Auto Power Off</td>
<td bgcolor="#c0d9d9" width="415">Approx. 10 minutes after the last switch operation</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Diameter of Measurable Conductor</td>
<td bgcolor="#c0d9d9" width="415">40mm maximum</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Dimensions</td>
<td bgcolor="#c0d9d9" width="415">Approx. 70mm (W) x 179mm (H) x 25mm (D)</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Weight</td>
<td bgcolor="#c0d9d9" width="415">Approx. 200g</td>
</tr>
<tr>
<td bgcolor="#b4cdcd" width="181">Accessories</td>
<td bgcolor="#c0d9d9" width="415">User manual, Battery and soft Carrying Case</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2"><span style="font-size: medium;">Ordering Information</span></td>
</tr>
<tr>
<td colspan="2">
<table border="1" width="100%" cellpadding="0" bgcolor="#f9f8ed">
<tbody>
<tr>
<td valign="top" bgcolor="#b4cdcd" width="237">Yokogawa 30031A</td>
<td bgcolor="#c0d9d9">Clamp-On Tester for AC Leakage Current Measurement. Includes: User&#8217;s manual, batteries, and carrying case.</td>
</tr>
<tr>
<td valign="top" bgcolor="#b4cdcd" width="237">Yokogawa 30032A</td>
<td bgcolor="#c0d9d9">Clamp-On Tester for AC Leakage Current Measurement. Includes: User&#8217;s manual, batteries, and carrying case.</td>
</tr>
</tbody>
</table>
</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-30031a-1ma60a-leakage-current-clamp-on-meters/">Yokogawa 30031A AC Leakage Current Clamp</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/yokogawa-30031a-1ma60a-leakage-current-clamp-on-meters/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Yokogawa 30032A 1uA/60A Leakage Current Clamp-On meters</title>
		<link>https://rapid-tech.com.au/yokogawa-30032a-1ua60a-leakage-current-clamp-on-meters/</link>
					<comments>https://rapid-tech.com.au/yokogawa-30032a-1ua60a-leakage-current-clamp-on-meters/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Sun, 14 Feb 2016 15:12:23 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/yokogawa-30032a-1ma60a-leakage-current-clamp-on-meters/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-33" src="http://rapid-tech.com.au/wp-content/uploads/2015/12/Yokogawa_logo_sml.jpg" alt="Yokogawa_logo_sml" width="110" height="20" /></p>
<p><a target="_blank" href="https://mymeter.com.au/product/yokogawa-30032a/" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<ul>
<li>Yokogawa 30032A can measure leakage currents of 1 uA, which is useful for checking the insulation of low-voltage circuits and electrical components.</li>
<li>Can measure a broad range of currents from leakage currents (at a resolution of 0.001 mA) to load currents up to 60 A.</li>
<li>Typical influence (on the current value of an adjacent cable) from an external magnetic field is 0.0005%.</li>
<li>Durability of clamp: More than 50,000 opening/closing events</li>
<li>Twice the tensional strength of Yokogawa M&#38;C's earlier model clamps</li>
<li>The clamp lever is lengthened by 30%, enabling smooth opening/closing of the clamp even for thick cables of 40mm in diameter.</li>
<li>Approved for conformity to safety standards EN 61010-1 and EN 61010-2-032 (CAT III 300V, pollution degree2)</li>
</ul>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg"><img class="alignnone size-full wp-image-5776" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg" alt="" width="200" height="186" /></a></p>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-30032a-1ua60a-leakage-current-clamp-on-meters/">Yokogawa 30032A 1uA/60A Leakage Current Clamp-On meters</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 class="da-mainH flirBlue da-light">Harmonic Filter Function (Available in the Yokogawa 30032A)</h2>
<p><strong>1. What is a Harmonic?</strong></p>
<p>Harmonic refers to sinusoidal quantity having a frequency that is an integral multiple of the fundamental frequency (for example, the commercial frequency). When a harmonic is superimposed on the fundamental frequency, the waveform is distorted.<br />
<strong>2. Why is it Necessary to Accurately Measure the Leakage Current of the Fundamental Frequency (Commercial Frequency)?</strong></p>
<p>One problem when measuring the leakage current to check the isolation of electrical circuits in power distribution equipment is that the electrical isolation cannot be correctly understood due to the influence of a harmonic current. That is, the leakage current flowing from the electrical circuit to ground is very small so that, in order to check the isolation of electrical circuits by means of the leakage current, it is necessary to remove the harmonic component of the leak current and measure only the current of the fundamental frequency (commercial frequency).<br />
<strong>3. The Yokogawa 30032A Employs a Harmonic Filter</strong></p>
<p>Conventional leakage clamp-on testers could not sufficiently remove harmonic current components so measured leakage current values were often larger than the specified value due to the influence of a harmonic current. In this case, retesting with an insulation tester was required, resulting in increased effort and cost for the test. Under these circumstances, Yokogawa Meters &amp; Instruments Corporation has developed the leakage clamp-on tester 30032A, which employs a high-performance harmonic filter that can accurately measure just the fundamental frequency component of the leakage current.</p>
<h3>Yokogawa 30032A Specifications</h3>
<div id="tab-specifications" class="tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom ui-tabs-hide">
<table class="spectable" cellspacing="0" cellpadding="0" align="center">
<tbody>
<tr>
<td class="speccellcategory" colspan="3">Yokogawa 30032A General Specifications</td>
</tr>
<tr>
<td class="speccelltitle">Method of Detection</td>
<td class="speccelldata" colspan="2">Mean Value</td>
</tr>
<tr>
<td class="speccelltitle">Diameter of Measurable conductor</td>
<td class="speccelldata" colspan="2">±40MM at maximum</td>
</tr>
<tr>
<td class="speccelltitle" rowspan="3">Display</td>
<td class="speccelldata" rowspan="3">LCD</td>
<td class="speccelldata">Digital Display: 3200 Counts</td>
</tr>
<tr>
<td class="speccelldata">Bar-graph Display: 32 Segments</td>
</tr>
<tr>
<td class="speccelldata">“OL” over-range indication<br />
<img decoding="async" src="http://assets.tequipment.net/assets/1/7/Yokogawa-30031A-batt.jpg" alt="Yokogawa-30031A-batt" /> Low-battery symbol<br />
<img decoding="async" src="http://assets.tequipment.net/assets/1/7/Yokogawa-30031A-DH.jpg" alt="Yokogawa-30031A-DH" /> Data hold symbol</td>
</tr>
<tr>
<td class="speccelltitle" rowspan="2">Measurement Cycle</td>
<td class="speccelldata" colspan="2">Digital Display: 2 times/Seconds</td>
</tr>
<tr>
<td class="speccelldata" colspan="2">Bar-Graph Display: 12 times/second</td>
</tr>
<tr>
<td class="speccelltitle">Range Switching</td>
<td class="speccelldata" colspan="2">Auto-Range</td>
</tr>
<tr>
<td class="speccelltitle">Data Hold</td>
<td class="speccelldata" colspan="2">On All range</td>
</tr>
<tr>
<td class="speccelltitle">Ambient Temperature and Humidity</td>
<td class="speccelldata" colspan="2">0-50°C, 85% RH or less (no condensation)</td>
</tr>
<tr>
<td class="speccelltitle">Temperature coefficient</td>
<td class="speccelldata" colspan="2">0.05% of range/°C or less (within the ranges of 0-18°C and 25-50°C for measurement of 0-50A)</td>
</tr>
<tr>
<td class="speccelltitle">Influence of external Magnetic Field</td>
<td class="speccelldata" colspan="2">0.0005% typical*1 (on current value of adjacent cable)</td>
</tr>
<tr>
<td class="speccelltitle">Influence of Conductor Position</td>
<td class="speccelldata" colspan="2">Within Accuracy</td>
</tr>
<tr>
<td class="speccelltitle">Circuit Voltage</td>
<td class="speccelldata" colspan="2">300Vrms or less</td>
</tr>
<tr>
<td class="speccelltitle">Withstanding Voltage</td>
<td class="speccelldata" colspan="2">3.7kV AC for one minute</td>
</tr>
<tr>
<td class="speccelltitle">Power Supply</td>
<td class="speccelldata" colspan="2">CR2032 (coin-shaped) 3V x1</td>
</tr>
<tr>
<td class="speccelltitle">Battery Life</td>
<td class="speccelldata" colspan="2">Approx. 90 hours (continuous use)</td>
</tr>
<tr>
<td class="speccelltitle">Auto Power-off</td>
<td class="speccelldata" colspan="2">Approx. 10 Minutes</td>
</tr>
<tr>
<td class="speccelltitle">Dimensions</td>
<td class="speccelldata" colspan="2">Approx. 70(W)x176(H)x25(D)mm</td>
</tr>
<tr>
<td class="speccelltitle">Weight</td>
<td class="speccelldata" colspan="2">Approx. 200g</td>
</tr>
</tbody>
</table>
<table class="spectable" cellspacing="0" cellpadding="0" align="center">
<tbody>
<tr>
<td class="speccellcategory" colspan="4">AC current measurement</td>
</tr>
<tr>
<td class="speccellheader" colspan="4">Filter function OFF</td>
</tr>
<tr>
<td class="speccelldata" colspan="4" align="right">Accuracy: ± (% of reading + digits)</td>
</tr>
<tr>
<td class="speccellcategory" align="center">Range</td>
<td class="speccellcategory" align="center">Resolution</td>
<td class="speccellcategory" align="center">Accuracy</td>
<td class="speccellcategory" align="center">Maximum<br />
Allowable Current</td>
</tr>
<tr>
<td class="speccelldata" align="center">3mA</td>
<td class="speccelldata" align="center">0.001mA</td>
<td class="speccelldata" rowspan="2" align="center">0.010 &lt; I ≤32.70mA:<br />
1.0%+5</td>
<td class="speccelldata" align="center">3.270mA</td>
</tr>
<tr>
<td class="speccelldata" align="center">30mA</td>
<td class="speccelldata" align="center">0.01mA</td>
<td class="speccelldata" align="center">32.70mA</td>
</tr>
<tr>
<td class="speccelldata" align="center">30A</td>
<td class="speccelldata" align="center">0.01A</td>
<td class="speccelldata" rowspan="2" align="center">0.05 &lt; I ≤50.0A:1.0%+5<br />
50.0 &lt; I ≤60.6A:5.0%+5</td>
<td class="speccelldata" align="center">32.70A</td>
</tr>
<tr>
<td class="speccelldata" align="center">60A</td>
<td class="speccelldata" align="center">0.1A</td>
<td class="speccelldata" align="center">60.6A</td>
</tr>
<tr>
<td class="speccellheader" colspan="4">Filter function ON</td>
</tr>
<tr>
<td class="speccelldata" align="center">3mA</td>
<td class="speccelldata" align="center">0.001mA</td>
<td class="speccelldata" rowspan="2" align="center">0.010 &lt; I ≤32.70mA:<br />
1.5%+5</td>
<td class="speccelldata" align="center">3.270mA</td>
</tr>
<tr>
<td class="speccelldata" align="center">30mA</td>
<td class="speccelldata" align="center">0.01mA</td>
<td class="speccelldata" align="center">32.70mA</td>
</tr>
<tr>
<td class="speccelldata" align="center">30A</td>
<td class="speccelldata" align="center">0.01A</td>
<td class="speccelldata" rowspan="2" align="center">0.05 &lt; I ≤50.0A:1.5%+5<br />
50.0 &lt; I ≤60.6A:5.5%+5</td>
<td class="speccelldata" align="center">32.70A</td>
</tr>
<tr>
<td class="speccelldata" align="center">60A</td>
<td class="speccelldata" align="center">0.1A</td>
<td class="speccelldata" align="center">60.6A</td>
</tr>
<tr>
<td class="speccelldata" colspan="4"><strong>Note:</strong> Input current of 2nd-order and higher harmonics<br />
: 150 mA rms maximum in the 3 mA/30 mA range<br />
: 62 A rms maximum in the 30 A/60 A range<br />
<strong>Filter specifications</strong> (3 mA and 30 mA ranges and 30 A and 60 A ranges)<br />
Amplitude ratio at 100 Hz: -38 dB (1.26%) or less (typical: -41 dB)<br />
Amplitude ratio at 120 Hz: -53 dB (0.22%) or less (typical: -56 dB)<br />
<strong>Zero correction</strong><br />
3 mA range: Displays 0.000 mA (zero) when 0.010 mA &lt; I<br />
30 A range: Displays 0.00 A (zero) when 0.05 A &lt; I</td>
</tr>
</tbody>
</table>
</div>
<p>&nbsp;</p>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-30032a-1ua60a-leakage-current-clamp-on-meters/">Yokogawa 30032A 1uA/60A Leakage Current Clamp-On meters</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/yokogawa-30032a-1ua60a-leakage-current-clamp-on-meters/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Yokogawa CL420 4mA to 20mA Clamp-On Process Meter for DC mA</title>
		<link>https://rapid-tech.com.au/yokogawa-cl420-4ma-to-20ma-clamp-on-process-meter-for-dc-ma/</link>
					<comments>https://rapid-tech.com.au/yokogawa-cl420-4ma-to-20ma-clamp-on-process-meter-for-dc-ma/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Sun, 14 Feb 2016 15:12:23 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/yokogawa-cl420-4ma-to-20ma-clamp-on-process-meter-for-dc-ma/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-33" src="http://rapid-tech.com.au/wp-content/uploads/2015/12/Yokogawa_logo_sml.jpg" alt="Yokogawa_logo_sml" width="110" height="20" /></p>
<p>Yokogawa CL420 DC mA Clamp-on Process Meter allows the user to make safe current checks of 4 to 20mA process current loops without breaking the process loop. In addition, the analogue output function provides a simple way to log and monitor the data.</p>
<p>The CL420 features 0.2% accuracy, 0.01mA resolution, dual display, LED backlight and has a 6mm diameter maximum jaw opening. The response time is approximately 1.5 seconds (2.5 seconds when across the range</p>
<p style="text-align: center;"><iframe src="https://www.youtube.com/embed/3H7iOTE8Gmc" width="560" height="315" frameborder="0" allowfullscreen="allowfullscreen"></iframe></p>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-cl420-4ma-to-20ma-clamp-on-process-meter-for-dc-ma/">Yokogawa CL420 4mA to 20mA Clamp-On Process Meter for DC mA</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Yokogawa CL420 4mA to 20mA Clamp-On Process Meter for DC mA</h3>
<p>The Yokogawa CL420 allows the user to make safe current checks of 4 to 20mA without breaking the loop. In addition, the output function provides a simple way to log and monitor the data.</p>
<p>The CL420 Clamp-on Process Meter will safely measure 0-120 mA DC process control signals without breaking the loop. Typical application examples include distributed control systems, programmable logic controllers, pressure and temperature transmitters, and loop powered isolators and indicators.</p>
<h4><strong>Yokogawa CL420 DC mA Clamp-on Process Meter Fe</strong><span class="text_exposed_show"><strong>atures</strong>:</span></h4>
<ul>
<li><span class="text_exposed_show">4-digit LCD Numeric Display.</span></li>
<li><span class="text_exposed_show">0.2% Accuracy, 0.01mA Resolution.</span></li>
<li><span class="text_exposed_show">Jaw Opening for up to 6mm wire size</span></li>
<li><span class="text_exposed_show">Dual Display.</span></li>
<li><span class="text_exposed_show">LED Backlight Display.</span></li>
<li><span class="text_exposed_show">Auto Ranging.</span></li>
<li><span class="text_exposed_show">Data Hold function.</span></li>
<li><span class="text_exposed_show">Zero adjust.</span></li>
<li><span class="text_exposed_show">Auto Power Off.</span></li>
<li><span class="text_exposed_show">Analogue Output</span></li>
<li><span class="text_exposed_show">Safety standards: EN61010-1, EN61010-2-030, EN61010-2-032</span></li>
</ul>
<table class="specsalt" cellpadding="2">
<tbody>
<tr>
<td class="standard8" colspan="3"><a></a><strong>Yokogawa CL420 4mA to 20mA Clamp-On Process Meter Specifications</strong></td>
</tr>
<tr>
<td class="specs4">Diameter of measurable conductor</td>
<td class="specs5" colspan="2">6mm diameter max.</td>
</tr>
<tr>
<td class="specs4" rowspan="2">DC Current</td>
<td class="specs5">Range and resolution [Measuring range]</td>
<td class="specs5">Measuring accuracy (*1)</td>
</tr>
<tr>
<td class="specs5">20.00 mA [0.00 to±21.49mA]
100.0 mA [±21.0 to ±126.0mA]</td>
<td class="specs5">±(0.2%rdg+5dgt) (*2)<br />
±(1.0%rdg+5dgt)</td>
</tr>
<tr>
<td class="specs4">DC Voltage OUTPUT</td>
<td class="specs5">20.00 mA [0.0 to±214.9mV]
100.0 mA [±210 to±1260mV]</td>
<td class="specs5">(DCA Accuracy)+(±0.5mV)<br />
(DCA Accuracy)+(±3mV)</td>
</tr>
<tr>
<td class="specs4">Display</td>
<td class="specs5" colspan="2">4-digit LCD Numeric display</td>
</tr>
<tr>
<td class="specs4">Response time</td>
<td class="specs5" colspan="2">Approx. 1.5 seconds (2.5 seconds when across the range)</td>
</tr>
<tr>
<td class="specs4">Range switching</td>
<td class="specs5" colspan="2">Auto range</td>
</tr>
<tr>
<td class="specs4">Operating temperature and humidity</td>
<td class="specs5" colspan="2">-10˚C to +50˚C 80% RH or less (no condensation)</td>
</tr>
<tr>
<td class="specs4">Safety Standards</td>
<td class="specs5" colspan="2">EN61010-1, EN61010-2-030, EN61010-2-032</td>
</tr>
<tr>
<td class="specs4">Withstanding voltage</td>
<td class="specs5" colspan="2">2.21kV AC for 5 seconds (between the core and the case)</td>
</tr>
<tr>
<td class="specs4">Power supply</td>
<td class="specs5" colspan="2">Four AA-size alkaline batteries (1.5V LR6)</td>
</tr>
<tr>
<td class="specs4">Battery life</td>
<td class="specs5" colspan="2">Approx. 60hrs (continuous) backlight off and LED light off</td>
</tr>
<tr>
<td class="specs4">Other functions</td>
<td class="specs5" colspan="2">Data hold, Zero adjust function, Auto power off, LED Torch light, Back light display, Illuminant panel</td>
</tr>
<tr>
<td class="specs4">External dimensions</td>
<td class="specs5" colspan="2">61 (W) x 111 (H) x 40 (D) mm</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-cl420-4ma-to-20ma-clamp-on-process-meter-for-dc-ma/">Yokogawa CL420 4mA to 20mA Clamp-On Process Meter for DC mA</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/yokogawa-cl420-4ma-to-20ma-clamp-on-process-meter-for-dc-ma/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Yokogawa CL340 40mA/400A Leakage Current Clamp-On Meters</title>
		<link>https://rapid-tech.com.au/yokogawa-cl340-40ma400a-leakage-current-clamp-on-meters/</link>
					<comments>https://rapid-tech.com.au/yokogawa-cl340-40ma400a-leakage-current-clamp-on-meters/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Sun, 14 Feb 2016 15:12:22 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/yokogawa-cl340-40ma400a-leakage-current-clamp-on-meters/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-33" src="http://rapid-tech.com.au/wp-content/uploads/2015/12/Yokogawa_logo_sml.jpg" alt="Yokogawa_logo_sml" width="110" height="20" /></p>
<p>The Yokogawa CL340 Clamp-on tester provides an easy-to read, 3999 count display. It measures current from 40 mA to 400 AAC.  It is an inexpensive, accurate and robust dedicated leakage meter with a mid-size clamp diameter  that accepts conductors up to 44 mm diameter.</p>
<h4>Applications</h4>
<ul class="bullit_lineItems">
<li>Preventative maintenance</li>
<li>Testing for current leakage on branch circuits</li>
<li>Measuring current draw of motors and motor control circuits</li>
<li>Measuring Loads</li>
</ul>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg"><img class="alignnone size-full wp-image-5776" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg" alt="" width="200" height="186" /></a></p>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-cl340-40ma400a-leakage-current-clamp-on-meters/">Yokogawa CL340 40mA/400A Leakage Current Clamp-On Meters</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Yokogawa CL340 Features</h3>
<ul>
<li>Mean value display</li>
<li>Auto power-off</li>
<li>Manual range switching</li>
<li>Approved for comformity to safety standards EN61010-1, EN61010-2-032 (CAT. III 300 V)</li>
</ul>
<h3>Yokogawa CL340 Specifications</h3>
<div id="tab-specifications" class="tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom ui-tabs-hide">
<table class="spectable" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellcategory" rowspan="2" width="82">
<div>Parameter</div>
</td>
<td class="speccellcategory" rowspan="2" width="181">
<div>Reference</div>
</td>
<td class="speccellcategory" colspan="2">
<div>Accuracy</div>
</td>
</tr>
<tr>
<td class="speccellcategory">
<div>WIDE(20Hz to)</div>
</td>
<td class="speccellcategory">
<div>50/60Hz</div>
</td>
</tr>
<tr>
<td class="speccelltitle" rowspan="3" valign="top">AC Current</td>
<td class="speccelldata" valign="top">40mA/400mA</td>
<td class="speccelldata" valign="top" width="150">2.5+10 (20 to 1kHz)</td>
<td class="speccelldata" valign="top" width="164">1.0+5 (50/60Hz)</td>
</tr>
<tr>
<td class="speccelldata" valign="top">400A(0 to 350A)</td>
<td class="speccelldata" valign="top">2.5+10 (40 to 1kHz)</td>
<td class="speccelldata" valign="top" width="164">1.0+5 (50/60Hz)</td>
</tr>
<tr>
<td class="speccelldata" valign="top">400A(350 to 400A)</td>
<td class="speccelldata" valign="top">5.0 (40 to 1kHz)</td>
<td class="speccelldata" valign="top">2.0 (50/60Hz)</td>
</tr>
<tr>
<td class="speccelltitle" colspan="4" valign="top">At 23 deg.C ±5 deg.C, 85% RH or less<br />
Accuracy: ±(% rdg + dgt) = ±(% readout + value of least significant digit)</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccelltitle" width="151">Method of detection</td>
<td class="speccelldata" width="415">Mean value</td>
</tr>
<tr>
<td class="speccelltitle" width="151">Display</td>
<td class="speccelldata">LCD(Digital display:3999 counts)</td>
</tr>
<tr>
<td class="speccelltitle" valign="top" width="151">Response Time</td>
<td class="speccelldata">Approx. 2 seconds</td>
</tr>
<tr>
<td class="speccelltitle" width="151">Range Switching</td>
<td class="speccelldata">Manual-range</td>
</tr>
<tr>
<td class="speccelltitle">Data Hold</td>
<td class="speccelldata">On all range</td>
</tr>
<tr>
<td class="speccelltitle">Peak Hold</td>
<td class="speccelldata">On all range</td>
</tr>
<tr>
<td class="speccelltitle" width="151">Ambient temperature and humidity</td>
<td class="speccelldata">0 to 40 deg.C, 85% RH or less (no condensation)</td>
</tr>
<tr>
<td class="speccelltitle" width="151">Temperature Coefficient</td>
<td class="speccelldata">_</td>
</tr>
<tr>
<td class="speccelltitle" width="151">Influence of external magnetic field</td>
<td class="speccelldata">10mA or less in proximity to a 15mm-dia conductor carrying 100A</td>
</tr>
<tr>
<td class="speccelltitle" rowspan="2" width="151">Influence of conductor position</td>
<td class="speccelldata">40/400mA range:Within 5dgt at every part inside the jaw400A range</td>
</tr>
<tr>
<td class="speccelldata">0 to 250A:Within ±0.5%rdg ±5dgt at every part inside the jaw section</td>
</tr>
<tr>
<td class="speccelltitle">Influence of residual current</td>
<td class="speccelldata">12mA or less in proximity to a 10mm-dia conductor carrying 100A</td>
</tr>
<tr>
<td class="speccelltitle" width="151">Safety Standard</td>
<td class="speccelldata">Conforms EN 61010-1, EN61010-2-032</td>
</tr>
<tr>
<td class="speccelltitle" width="151">Circuit Voltage</td>
<td class="speccelldata">300Vrms or less</td>
</tr>
<tr>
<td class="speccelltitle" width="151">Withstanding Voltage</td>
<td class="speccelldata">3.7kV AC for one minute</td>
</tr>
<tr>
<td class="speccelltitle" width="151">Power Supply</td>
<td class="speccelldata">R0-3(UM-4) × 2 or LR03 × 2</td>
</tr>
<tr>
<td class="speccelltitle" width="151">Battery Life</td>
<td class="speccelldata">Approx. 40 hours (continuous)</td>
</tr>
<tr>
<td class="speccelltitle" width="151">Consumed Current</td>
<td class="speccelldata">Approx. 13mA</td>
</tr>
<tr>
<td class="speccelltitle" width="151">Auto power-off</td>
<td class="speccelldata">Approx. 10 minutes</td>
</tr>
<tr>
<td class="speccelltitle" width="151">Diameter of measurable conductor</td>
<td class="speccelldata">40mm at maximum</td>
</tr>
<tr>
<td class="speccelltitle" width="151">Dimensions</td>
<td class="speccelldata">Approx. 81(W) × 185(H) × 40(D)mm</td>
</tr>
<tr>
<td class="speccelltitle" width="151">Weight</td>
<td class="speccelldata">Approx. 270g</td>
</tr>
<tr>
<td class="speccelltitle" width="151">Accessories</td>
<td class="speccelldata">User&#8217;s manual(IM CL340), batteries, carrying case(93030)</td>
</tr>
</tbody>
</table>
</div>