<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Calibrators Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/calibrators-portablehandheld/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/calibrators-portablehandheld/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Tue, 24 Jun 2025 07:00:02 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.10</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>Calibrators Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/calibrators-portablehandheld/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Multi-Function Process Calibrator &#8211; HART &#124; YOKOGAWA CA500 Series</title>
		<link>https://rapid-tech.com.au/yokogawa-ca500-calibrator/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Mon, 15 Mar 2021 02:50:37 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=17445</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/10/Yokogawa-Logo-Medium.jpg"><img class="alignnone size-full wp-image-5623" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/Yokogawa-Logo-Medium.jpg" alt="" width="250" height="50" /></a></p>
<p><a target="_blank" href="https://mymeter.com.au/product/yokogawa-ca550-f3-te-multi-function-process-calibrator/" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="" width="160" height="40" /></a></p>
<p>The Yokogawa <strong>CA500 and CA550 are high-performance, multi-function calibrators - HART</strong> designed for use in multiple applications.</p>
<p>Featuring functions <strong>ideal for field work,</strong> these multi-function calibrators <strong>help you calibrate field instruments</strong> with improved source and measurement accuracy.</p>
<p><strong>Two models are available,</strong> offering two different levels of accuracy:</p>
<ul>
<li><strong>The CA500</strong> achieves an accuracy of 0.015% (DC current), 0.020% (resistance), and 0.3˚C (RTD).</li>
<li><strong>The CA550</strong> achieves an accuracy of 0.010% (DC current), 0.015% (resistance), and 0.1˚C (RTD).</li>
</ul>
<p><strong><img class="alignnone size-full wp-image-17809" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-Download-e1620015214396.png" alt="PDF Download icon" width="51" height="60" /> <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2021/03/CA500-series-Brochure.pdf" rel="noopener">CA500 series Brochure</a></span>    <img class="alignnone size-full wp-image-17809" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-Download-e1620015214396.png" alt="PDF Download icon" width="51" height="60" /> <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2021/03/CA500-series-Getting-Started-Guide.pdf" rel="noopener">CA500 series Getting Started Guide</a></span></strong></p>
<p><strong><img class="alignnone size-full wp-image-17809" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-Download-e1620015214396.png" alt="PDF Download icon" width="51" height="60" /> <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2021/03/CA500-series-User-Manual.pdf" rel="noopener">CA500 series User Manual</a></span></strong></p>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-ca500-calibrator/">Multi-Function Process Calibrator &#8211; HART | YOKOGAWA CA500 Series</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>YOKOGAWA CA500 Series Multi-Function Process Calibrator &#8211; HART</h3>
<ul>
<li>Sources and measures DC voltage, DC current, RTD, TC, resistance, frequency and pulse signals</li>
<li>Corresponds to 17 types of TC standard (JIS/IEC/DIN/ASTM/GOST R)</li>
<li>Corresponds to 14 types of RTD standard (JIS/IEC/GOST R)</li>
</ul>
<h3>Multiple source patterns</h3>
<p style="padding-left: 40px;"><strong>Linear sweep function</strong><br />
Continuously Source from 0% to 100%</p>
<p style="padding-left: 40px;"><strong>Step sweep function</strong><br />
Change output in a staircase (step) pattern by specifying the number of steps. (The number of steps can be set from 2 to 20)</p>
<p style="padding-left: 40px;"><strong>Program sweep function</strong><br />
Users can set the desired output value (%) and number of steps. (10 steps for CA500, 20 steps for CA550)</p>
<h3><span style="font-size: 120%;">Functions</span></h3>
<h4>Automatic input/output testing *CA550 only (Program sweep)</h4>
<p>Automatic input/output testing is possible by setting source values for each step for a calibration target. Calibration results such as generated value, measured value, error rate, date/time, and pass/fail are saved in CSV format in the CA550 main unit.</p>
<p>By connecting the CA550 to a PC using a standard USB cable, the instrument can be recognized as a mass-storage device for data to be transferred to the PC.</p>
<h3>HART Communication Protocol *CA550 only</h3>
<h4>Firmware Ver2.03 or later (released)</h4>
<p>&nbsp;</p>
<p><strong><em>The following items are supported by HART communication function:</em></strong></p>
<div class="table-responsive">
<table border="1">
<tbody>
<tr>
<td>
<ul>
<li>LOOP TEST</li>
</ul>
</td>
<td align="center">—</td>
</tr>
<tr>
<td>
<ul>
<li>TagNo.</li>
<li>PV value (including reading of PV %value, AO value, SV value, TV value, QV value)</li>
</ul>
</td>
<td align="center">Read</td>
</tr>
<tr>
<td>
<ul>
<li>LRV (Lower limit of range)</li>
<li>URV (Upper limit of range)</li>
<li>Damping</li>
</ul>
</td>
<td align="center">Read and Write</td>
</tr>
<tr>
<td>
<ul>
<li>Trimming of 4 mA</li>
<li>Trimming of 20 mA</li>
<li>PV Zero</li>
</ul>
</td>
<td align="center">Write</td>
</tr>
</tbody>
</table>
</div>
<p>*HART communication that supports some of the universal commands and common Practice commands.<br />
*BRAIN communication only supports acquisition of Tag No.</p>
<h3>Easy-to-view Display</h3>
<div class="imageright">
<div class="imageright-cell">
<div class="imageright-content">
<p>CA500 series features a Reflective LCD, providing improved outdoor visibility. Main display (generated/measured values) and Sub display (%, mV, Ω, etc.) allow required information at a work site to be confirmed at a glance</p>
<h3>Wiring information display function</h3>
<div class="imageright">
<div class="imageright-cell">
<div class="imageright-content">
<p>A wiring diagram is displayed on the screen according to the function selected. This function allows a user to perform wiring while referring to the displayed wiring diagram and prevents mis-wiring.</p>
<h3><span style="color: #333333;">Thermocouple generation using TC Mini Plug</span></h3>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="imageright">
<div class="imageright-cell">
<div class="imageright-content">
<p>Using a TC Mini Plug together with a compensating lead wire enables generation of thermal electromotive force without an external RJ sensor.*<br />
<span style="font-size: 85%;">* A compensating lead wire needs to be prepared by customer.</span></p>
</div>
</div>
</div>
<h4>Easy-to-use key operation</h4>
<div class="imageright">
<div class="imageright-cell">
<div class="imageright-content">
<p><strong>0% / 100% keys</strong><br />
The source can be easily switched between 0% and 100% of range. Users can also set a desired value.</p>
</div>
</div>
</div>
<div class="imageright">
<div class="imageright-cell">
<div class="imageright-content">
<p><strong>UP/DOWN keys</strong><br />
The output is changed in preset steps by pressing UP or DOWN key.</p>
</div>
</div>
</div>
<div class="imageright">
<div class="imageright-cell">
<div class="imageright-content">
<p><strong>Operation key layout</strong><br />
Keys related to generation and measurement are arranged collectively to allow easy and intuitive operation.</p>
</div>
</div>
</div>
<h3>SQUARE ROOT output</h3>
<div class="imageright">
<div class="imageright-cell">
<div class="imageright-content">
<p>For 4-20 mA, 1-5 V ranges, users can choose between LINEAR and SQUARE ROOT output.</p>
</div>
<h4>20 mA SIMULATE</h4>
<p>The CA500 series can be used as a transmitter simulator to perform a loop test. It sinks the set current from an external voltage source of instrumentation equipment.</p>
<h4>Two-wire Transmitter Loop Check</h4>
<p>DC mA signals can be measured by supplying power to the transmitter from a 24 V DC power supply. DC mA signal measurement and zero-point check can be performed with an accuracy of 0.01% of reading (0.015% of reading for CA500).</p>
</div>
<h4>Zero point adjustment of HART transmitter</h4>
<p>CA550 supports HART communication (Universal command/Common practice command).<br />
Reading of HART device information, writing of LRV/URV, and trimming of analog output are possible.</p>
</div>
<h4>THERMOCOUPLE SIMULATE</h4>
<p>The CA500 series corresponds to 17 types of TC for sourcing. It achieves the high basic accuracy of 0.5°C (typical of type K), two times better than the previous model.</p>
<p>Also, input/output testing is possible with a single CA500/CA550, as it can measure output signals.</p>
<h4>RTD SIMULATE</h4>
<p>CA500/CA550 corresponds to 14 types of RTD for sourcing. It achieves a high basic accuracy of 0.1°C* (typical of type Pt100), which enables it to operate a highly reliable test.</p>
<p>Additionally, input and output testing of temperature transmitters is possible at the same time.<br />
<span style="font-size: 85%;">*Accuracy for CA550</span></p>
<h4>PULSE SIMULATE</h4>
<p>The CA500 performs measurement of pulse signal integration from a flowmeter and generates a pulse to a receiver, such as integrating counter or pulse converter. Integration time can be set from 1 min to 60 min.</p>
<p><span data-sheets-value="{&quot;1&quot;:2,&quot;2&quot;:&quot;YOKOGAWA CA500&quot;}" data-sheets-userformat="{&quot;2&quot;:18945,&quot;3&quot;:{&quot;1&quot;:0},&quot;12&quot;:0,&quot;14&quot;:{&quot;1&quot;:2,&quot;2&quot;:16711680},&quot;17&quot;:1}">YOKOGAWA CA500</span> Documenting Process Calibrator-HART is an alternative product to the Fluke 754</p>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-ca500-calibrator/">Multi-Function Process Calibrator &#8211; HART | YOKOGAWA CA500 Series</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>YOKOGAWA LS3300 AC Power Calibrator</title>
		<link>https://rapid-tech.com.au/yokogawa-ls3300-ac-power-calibrator/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Mon, 21 May 2018 18:25:59 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=7594</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/10/Yokogawa-Logo-Medium.jpg"><img class="alignnone size-full wp-image-5623" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/Yokogawa-Logo-Medium.jpg" alt="" width="250" height="50" /></a></p>
<p>The Yokogawa LS3300 is built upon the technology of its predecessor, the 2558A, the LS3300 is an AC signal generator capable of outputting both current and voltage simultaneously, thus allowing it to calibrate power meters.</p>
<p>Providing output ranges of 10mV-1250V, and 0.3 mA to 62.5 A, and upto 78.125 kW, the unit is capable of calibrating up to 0.15 % Class Power meters.</p>
<p>New features on the LS3300 include a high definition LCD display, a vector diagram, and the ability to synchronize up to three units to emulate anything from single phase two wire to three phase four wire systems.</p>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="font-size: 110%;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2018/05/Yokogawa-LS3300-Brochure.pdf" rel="noopener">Yokogawa LS3300 Brochure</a></span></h4>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="font-size: 110%;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2018/05/Yokogawa-LS3300-User-Manual.pdf" rel="noopener">Yokogawa LS3300 User Manual</a></span></h4>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-ls3300-ac-power-calibrator/">YOKOGAWA LS3300 AC Power Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="product_page">
<div class="row">
<div class="columns medium-7 medium-offset-5">
<div class="panel radius additional-links">
<div class="row">
<div class="columns small-6"></div>
</div>
</div>
</div>
</div>
</div>
<div class="tabs-content">
<div id="Details" class="content active">
<h3 id="tabs-target" class="tabs-container tabs-top ">YOKOGAWA LS3300 AC Power Calibrator</h3>
<div class="tabs-content">
<div id="Details_Features" class="content active">
<div class="wysiwyg-content mod-tab">
<p>The LS3300 is a single-phase AC power calibrator that can generate highly accurate, stable, and wide range output current and voltage. New features include an LCD display and a “STABILIZING function” which shows that the output signal is stabilized for calibration efficiency.</p>
<h4><strong><span style="font-size: 110%;">The Yokogawa LS3300 provides:</span></strong></h4>
<p><strong><span style="font-size: 110%;">Technology</span> </strong>– The LS3300 delivers <strong>best-in-class power accuracy</strong> of 100 ppm and high output current of 62.5 A.</p>
<p><strong><span style="font-size: 110%;">Confidence</span> </strong>– Yokogawa’s attention to quality ensures engineers have the peace of mind knowing that the LS3300 is designed to meet the high stability and accuracy needed for testing power meters.</p>
<p><strong><span style="font-size: 110%;">Operability</span></strong> – Combining flexibility of single to three phase calibration and a suite of features for power meter validation, The LS3300 is an excellent choice for efficient, expeditious calibration</p>
<p style="text-align: center;"><a href="https://rapid-tech.com.au/wp-content/uploads/2018/05/LS3300-2.png"><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-7598" src="https://rapid-tech.com.au/wp-content/uploads/2018/05/LS3300-2.png" alt="" width="600" height="432" srcset="https://rapid-tech.com.au/wp-content/uploads/2018/05/LS3300-2.png 600w, https://rapid-tech.com.au/wp-content/uploads/2018/05/LS3300-2-300x216.png 300w" sizes="(max-width: 600px) 100vw, 600px" /></a></p>
<div class="row"  id="row-694212334">

	<div id="col-1074367147" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<h4>Front Panel:</h4>
<ol>
<li>LO TO EARTH LAMP (voltage)</li>
<li>LO TO EARTH LAMP (current)</li>
<li>HIGH VOLTAGE LAMP</li>
<li>Current output terminals</li>
<li>Voltage output terminals</li>
<li>AUX output terminal</li>
<li>OUTPUT ON/OFF key</li>
<li>Output select key</li>
</ol>
		</div>
					</div>

	

	<div id="col-1807828760" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<h4>Rear Panel:</h4>
<ol>
<li>Output terminals for synchronized operation</li>
<li>Input terminals for synchrenized operation</li>
<li>Functional ground</li>
<li>USB port</li>
<li>Ethernet port</li>
<li>GP-IB connector</li>
<li>Link interface (UNIT2/UNIT3)</li>
</ol>
		</div>
					</div>

	
</div>
<h3><strong>YOKOGAWA LS3300 AC Power Calibrator Specifications:</strong></h3>
<h3>High Accuracy</h3>
<p>AC Voltage: ±350 ppm<br />
AC Current: ±450 ppm<br />
AC Power: ±450 ppm<br />
At 1 year, 10 ppm = 0.001%</p>
<h3>Phase Accuracy</h3>
<p>±0.03º at 50/60 Hz<br />
Between the Voltage and current outputs when used alone.</p>
<h3>High Stability</h3>
<p>AC voltage, current: ±50 ppm/h<br />
AC power: ±100 ppm/h<br />
From 1 minute to 1 hour after the output is turned on.</p>
<h3>Wide generation range</h3>
<p>AC voltage: 10 mV to 1250 V<br />
AC current: 0.3 mA to 62.5 A<br />
Frequency: 40 to 1200 Hz</p>
<h3>Single to three phase power calibration</h3>
<p>A single LS3300 AC Power Calibrator unit supports 1P2W, and multiple LS3300 units support 1P3W, 3P3W and 3P4W. It can calibrate AC voltage/ current, active/reactive power, power factor and phase angle.</p>
</div>
<h3>Control and output of three phase power</h3>
<p>Multiple LS3300 AC Power Calibrators can be synchronized through BNC cables. The host can then connect all units to the master unit via a USB cable and adjust settings simultaneously through the master/slave communication. Users can set the values of voltage, current, power, power factor, wiring, and phase from the front panel of the master unit and view each phase in a phase chart in the LCD. Checking the output of each unit from the master unit during three-</p>
<p><strong>(1) Outputting balanced three-phase signals</strong></p>
<p>In the case of balanced phase signals, when users modify settings on the master unit, values on the slave units are set accordingly. Synchronous communication allows output setting changes on the master unit to be migrated to the slave unit. If a fault such as an overload occurs in the slave unit, this information will be conveyed to the master unit, and  a shutdown of the output is initiated.</p>
<p><strong>(2) Outputting unbalanced three-phase signals</strong></p>
<p>In the case of unbalanced phase signals, users set the conditions of a balanced state for the slave units on the master unit. Then they change the phase setting into single phase and manually set conditions of the unbalanced phase state of each phase on the slave side.</p>
<h3>On-Site calibration service</h3>
<p>Other power calibration systems in the market utilize a master/slave interface where-in the slave units cannot be operated standalone for single phase output. Each LS3300, on the other hand, is capable of both independent single phase output, as well as synchronized three phase output. Its excellent portability enables feasible on- site calibration service.</p>
<h3>Large current output up to 180 A</h3>
<p>When users synchronize three units and connect their output in parallel, the system can output up to 180 A, when [Hi Current] is specified in the Wiring menu. LS3300 supports devices requiring large current such as a current sensor, smart meter, etc.</p>
<p>phase output is done by navigating to [CONFIG] &gt; [Unit] key &gt; menu.</p>
</div>
</div>
<h3>Diversification of the calibration equipment by AUX output</h3>
<p>A large current sensor used for industrial equipment and a clamp-on power meter used to monitor energy-saving are widely used in the power measurement market. When a clamp-on power meter unit or external current sensor input (voltage output) is calibrated, an AUX terminal is used. The voltage output range of the auxiliary output is  0 to 6.25 V.<br />
Users can select either the 500 mV or 5 V range according to the range of a current sensor input.</p>
</div>
<h3>LCD for enhanced viewing capabilities</h3>
<p>The LS3300 is equipped with a 5.7-inch color LCD. It shows the wiring and power settings, as well as the phase chart of the generated waveforms, allowing users to quickly and easily view the instrument settings (as seen below). Users are also able to view the unit information such as the serial number, firmware version information, and communication settings in the UTILITY menu.<br />
The values of voltage, current, active power and reactive power specified according to the level, level ratio and power factor are displayed as output values.</p>
</div>
<h3>Reduced calibration times</h3>
<p><strong>(1) Notification of output stabilization</strong></p>
<p>To improve working efficiency, the LS3300 is equipped with a function for notifying the user that the output is stable. When the <strong>STABILIZING</strong> indicator disappears from the LCD (two seconds later), it means that the output has stabilized. This reduces time spent working with transient signals that affect measurement accuracy.</p>
<h3>Safety features during calibration</h3>
<p><strong>(1) High voltage notification</strong></p>
<p>This function notifies users of dangerous high voltage conditions when using high voltage ranges (300 or 1000 V). When the voltage output is set to 150 V or higher, the device beeps intermittently to notify users.</p>
<p><strong>(2) Trip detection</strong></p>
<p>If a connected  load  causes the output range to be exceeded, the Yokogawa LS3300 detects the abnormal load conditions to protect itself. This function monitors the error of overcurrent, overvoltage, oscillation, fan malfunction and temperature.</p>
<p><strong>(3) LINE synchronization</strong></p>
<p>The output frequency of this product can be synchronized with commercial power frequency. This feature is useful in verifying interferences from the power source.</p>
<h3>Communication interface</h3>
<p>The LS3300 AC Power Calibrator is equipped with USB, Ethernet and GP-IB as standard communication interface to control external devices remotely.</p>
<p>&nbsp;</p>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-ls3300-ac-power-calibrator/">YOKOGAWA LS3300 AC Power Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Yokogawa MC100 Pneumatic Pressure Standard</title>
		<link>https://rapid-tech.com.au/yokogawa-mc100-pneumatic-pressure-standard/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sun, 05 Nov 2017 04:04:07 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=5819</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/10/Yokogawa-Logo-Medium.jpg"><img class="alignnone size-full wp-image-5623" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/Yokogawa-Logo-Medium.jpg" alt="" width="250" height="50" /></a></p>
<p>&#160;</p>
<h3><a href="https://rapid-tech.com.au/wp-content/uploads/2017/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-5148" src="https://rapid-tech.com.au/wp-content/uploads/2017/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/Yokogawa-MC100-Datasheet.pdf" target="_blank" rel="noopener">Y<span style="color: #0000ff;">okogawa MC100 Datasheet</span></a></h3>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg"><img class="alignnone size-full wp-image-5776" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg" alt="" width="200" height="186" /></a></p>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-mc100-pneumatic-pressure-standard/">Yokogawa MC100 Pneumatic Pressure Standard</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The<strong> Yokogawa MC100 Series</strong> is well-suited for calibration and maintenance of pressure instrumentation.</p>
<p>Various pressure instruments such as pressure sensors, industrial transmitters, and pressure switches, as well as sphygmomanometers and other medical devices face severe price competition and demands for improved accuracy.</p>
<p><strong>The Yokogawa MC100 Pneumatic Pressure Standard meets your many requirements with these features:</strong></p>
<ul>
<li>High accuracy ±(0.05% of full scale)</li>
<li>Excellent stability provided by silicon resonant sensor</li>
<li>Low temperature coefficient Zero point: ±0.003% of full scale/°C Span: ±0.002% of full scale/°C</li>
<li>Divided output function with as many as 20 steps</li>
<li>Auto-step output function</li>
<li>Sweep output function</li>
<li>Offset monitor function to present deviation from final value</li>
</ul>
<h3>Silicon resonant sensor</h3>
<div class="imageleft">
<div class="imageleft-cell">
<div class="imageleft-image">
<div>
<div>
<div><img decoding="async" src="http://cdn.tmi.yokogawa.com/fe7aa6589bed1f73f0b5b2f233459c736ee7fe33.gif" alt="Silicon resonant sensor" /></div>
</div>
</div>
</div>
</div>
<div class="imageleft-cell">
<div class="imageleft-content">
<ul>
<li><strong>High sensitivity and resolution and superior long-term stability</strong><br />
The vibrators are in a vacuum. This reduces the dispersion of vibration energy. Combined with the superior flexibility of monocrystal silicon, this makes it possible to obtain a high Q value.</li>
<li><strong>Extremely low temperature dependence</strong><br />
Two vibrators are used, and pressure is derived from the difference between the two unique oscillation counts. With this operating structure, it is possible to cancel out external environment influences such as ambient temperature. In addition, the oscillators are in a vacuum, so they are not affected by ambient temperature or humidity.</li>
</ul>
</div>
</div>
</div>
<h3>Yokogawa MC100 Front Panel</h3>
<p><img decoding="async" src="http://cdn.tmi.yokogawa.com/2242417ba413fc2643ff7764ffb876b21345ad31.jpg" alt="Front Panel" /></p>
<h3>Yokogawa MC100 Rear Panel</h3>
<p><img decoding="async" src="http://cdn.tmi.yokogawa.com/b468c0568d87565a168fee138d4cf67b8a9cd9dd.jpg" alt="Rear Panel" /></p>
<h3>Calibration System</h3>
<p><img decoding="async" src="http://cdn.tmi.yokogawa.com/2b138d9860e6e97157db1a9fc1fbec1775388f8c.gif" alt="Calibration System" /></p>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-mc100-pneumatic-pressure-standard/">Yokogawa MC100 Pneumatic Pressure Standard</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Yokogawa CA700 Pressure Calibrator</title>
		<link>https://rapid-tech.com.au/yokogawa-ca700-pressure-alibratr/</link>
					<comments>https://rapid-tech.com.au/yokogawa-ca700-pressure-alibratr/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Wed, 21 Dec 2016 20:01:10 +0000</pubDate>
				<guid isPermaLink="false">http://rapid-tech.com.au/?post_type=product&#038;p=4572</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/10/Yokogawa-Logo-Medium.jpg"><img class="alignnone size-full wp-image-5623" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/Yokogawa-Logo-Medium.jpg" alt="" width="250" height="50" /></a></p>
<p>The Yokogawa CA700 Pressure Calibrator is a highly accurate and highly functional pressure calibrator specifically designed for the calibration of differential pressure and pressure transmitters, which are widely used in plant processes these days and are improving in terms of accuracy and functionality.</p>
<p>The CA700 has achieved the highest accuracy and widest range in the products class, enabling field calibration with greater accuracy than ever before.</p>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg"><img class="alignnone size-full wp-image-5776" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg" alt="" width="200" height="186" /></a></p>
<p>&#160;</p>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-ca700-pressure-alibratr/">Yokogawa CA700 Pressure Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Yokogawa CA700 Pressure Calibrator has a basic accuracy of 0.01% of rdg on pressure measurement and 0.015% of rdg on Current / Voltage of the source and measurement portions of the CA700. The CA700 is the most accurate calibrator in the portable calibrator class. It also has the highest resolution and widest range of any hand held portable in its class with resolution of 0.001 kpa (200.00 kpa range) and a resolution of 0.0001 psi (29 psi range)</p>
<p><strong>Applications for the Yokogawa CA700 include:</strong></p>
<ul>
<li>Field calibration of differential pressure and pressure transmitters</li>
<li>Pressure switch test</li>
<li>Check and I/O adjustment of an electro-pneumatic converter</li>
<li>20 mA SIMULATE (two-wire transmitter simulator)</li>
<li>Two-wire transmitter loop check</li>
<li>Input command check and adjustment of recorders and controllers</li>
</ul>
<h3>Yokogawa CA700 Features:</h3>
<ul>
<li>Achieves the highest accuracy in the portable class</li>
<li>Available ranges:
<ul>
<li>-80 to 200 kPa</li>
<li>-80 to 1000 kPa</li>
<li>-80 to 3500 kPa</li>
</ul>
</li>
<li>Basic accuracy:
<ul>
<li>Pressure; 0.01% rdg</li>
<li>Current/voltage; 0.015% rdg</li>
</ul>
</li>
<li>0.001 kPa resolution</li>
<li>Calibration procedures are embedded</li>
<li>IP54 dustproof and waterproof</li>
</ul>
<table id="Specifications">
<tbody>
<tr>
<td class="Table_Green_Background_BLRT" colspan="4"><strong>Yokogawa CA700 Calibrator Specifications:</strong></td>
</tr>
<tr>
<td class="Table_Blue_Background_BLR">Pressure Measurement</td>
<td class="Table_Blue_Background_BR">CA700-E-01</td>
<td class="Table_Blue_Background_BR">CA700–E–02</td>
<td class="Table_Blue_Background_BR">CA700–E–03</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Pressure Type</td>
<td class="Table_cell_outline_BRC" colspan="3">Gauge</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Measurement range:</td>
<td class="Table_cell_outline_BR">Pos. : 0 to 200 kPa<br />
Neg. : -80 to 0 kPa</td>
<td class="Table_cell_outline_BR">Pos. : 0 to 1000 kPa<br />
Neg. : -80 to 0 kPa</td>
<td class="Table_cell_outline_BR">Pos. : 0 to 3500 kPa<br />
Neg. pressure: -80 to 0 kPa</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Measurement display range:</td>
<td class="Table_cell_outline_BR">To 240.000 kPa</td>
<td class="Table_cell_outline_BR">To 1200.00 kPa</td>
<td class="Table_cell_outline_BR">To 4200.00 kPa</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Resolution:</td>
<td class="Table_cell_outline_BR">0.001 kPa</td>
<td class="Table_cell_outline_BR">0.01 kPa</td>
<td class="Table_cell_outline_BR">0.01 kPa</td>
</tr>
<tr>
<td class="Table_Blue_Background_BLR" colspan="4"></td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Meas. accuracy 6mo.:<br />
Positive pressure:</td>
<td class="Table_cell_outline_BR">20 to 200 kPa:<br />
±(0.01% of rdg + 0.003 kPa)<br />
0 to 20 kPa: ±(0.005 kPa)</td>
<td class="Table_cell_outline_BR">(0.01% of rdg + 0.04 kPa)</td>
<td class="Table_cell_outline_BR">±(0.01% of rdg + 0.15 kPa)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Meas. accuracy 6mo.:<br />
Negative pressure:</td>
<td class="Table_cell_outline_BR">±(0.2% of rdg + 0.080 kPa)</td>
<td class="Table_cell_outline_BR">±(0.2% of rdg + 0.08 kPa)</td>
<td class="Table_cell_outline_BR">±(0.2% of rdg + 0.08 kPa)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Meas. accuracy 1yr.:<br />
Positive pressure:</td>
<td class="Table_cell_outline_BR">20 to 200 kPa:<br />
±(0.01% of rdg + 0.010 kPa)<br />
0 to 20 kPa: ±0.012 kPa</td>
<td class="Table_cell_outline_BR">±(0.01% of rdg + 0.08 kPa</td>
<td class="Table_cell_outline_BR">±(0.01% of rdg + 0.30 kPa)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Meas. accuracy 1yr.:<br />
Negative pressure:</td>
<td class="Table_cell_outline_BR">±(0.2% of rdg + 0.090 kPa)</td>
<td class="Table_cell_outline_BR">±(0.2% of rdg + 0.09 kPa)</td>
<td class="Table_cell_outline_BR">±(0.2% of rdg + 0.09 kPa)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Response time:</td>
<td class="Table_cell_outline_BRC" colspan="3">2.5 s or less</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Allowable input:</td>
<td class="Table_cell_outline_BR">2.7 kPa abs to 500 kPa gauge</td>
<td class="Table_cell_outline_BR">2.7 kPa abs to 3000 kPa gauge</td>
<td class="Table_cell_outline_BR">2.7 kPa abs to 4500 kPa gauge</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Internal volume:</td>
<td class="Table_cell_outline_BRC" colspan="3">Approx. 6 cm<sup>3</sup></td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Temperature coefficient:</td>
<td class="Table_cell_outline_BRC" colspan="3">±(0.001% of reading + 0.001% of full scale)/°C or less</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Influence of positional setup:</td>
<td class="Table_cell_outline_BRC" colspan="3">Zero-point drift ±0.3 kPa or less</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Measurement fluid:</td>
<td class="Table_cell_outline_BRC" colspan="3">Gas and liquid (non-corrosive, non-flammable, non-explosive, and non-toxic fluids)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Measurement fluid temperature:</td>
<td class="Table_cell_outline_BRC" colspan="3">-10 to 50°C</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Pressure sensor:</td>
<td class="Table_cell_outline_BRC" colspan="3">Silicon resonant sensor</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Pressure sensor element:</td>
<td class="Table_cell_outline_BRC" colspan="3">Diaphragm</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Pressure display units:</td>
<td class="Table_cell_outline_BRC" colspan="3">kPa and other units<br />
(Pa, hPa, MPa, mbar, bar, atm, mmHg, inHg, gf/cm2, kgf/cm2, mmH2O@4°C, mmH2O@20°C, ftH2O@4°C, ftH2O@20°C, inH2O@4°C, inH2O@20°C, Torr, psi )</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Input port:</td>
<td class="Table_cell_outline_BRC" colspan="3">Rc 1/4 or 1/4 NPT female thread (selectable</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Measurement unit material:</td>
<td class="Table_cell_outline_BRC" colspan="3">Diaphragm: Hastelloy C276 and input port: SUS316</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table id="General">
<colgroup>
<col />
<col /></colgroup>
<tbody>
<tr>
<td class="Table_Green_Background_BLRT" colspan="2"><strong>Yokogawa CA700 General Specifications:</strong></td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Display:</td>
<td class="Table_cell_outline_BR">Dot matrix LCD (320×240 dots) c/w LED Backlight</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Display refresh rate;</td>
<td class="Table_cell_outline_BR">Approx. 300ms (3 times/sec)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Warm-up time:</td>
<td class="Table_cell_outline_BR">Approx. 5 minutes</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Power Voltage:</td>
<td class="Table_cell_outline_BR">Six alkaline AA batteries</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Battery life:</td>
<td class="Table_cell_outline_BR">Approx. 35 hours when measuring current with the 24 V loop power supply OFF and approx 10 hours with the 24 V loop power supply ON</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Auto power-off:</td>
<td class="Table_cell_outline_BR">Approx. 60 minutes (the function can be disabled)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Insulation resistance:</td>
<td class="Table_cell_outline_BR">100 MΩ or more (500 VDC) between the input terminal and case and between the input port and case</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Withstand voltage:</td>
<td class="Table_cell_outline_BR">500 VAC for 1 minute between the input terminal and case and between the input port and case</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Protection grade:</td>
<td class="Table_cell_outline_BR">IP54 dustproof and waterproof structure</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Dimensions:</td>
<td class="Table_cell_outline_BR">Approx. 264 (W) x 188 (H) x 96 (D) mm, excluding protrusions</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Weight:</td>
<td class="Table_cell_outline_BR">Approx. 2kg (including batteries</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Compliance standards:</td>
<td class="Table_cell_outline_BR">Safety: EN61010-1, EN61010-2-030, contamination class 2<br />
EMC: EN61326-1 Class A, EN55011 Class A Group 1</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Operating temperature:</td>
<td class="Table_cell_outline_BR">-10 to 50°C and 20 to 80%RH (no condensation)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Storage temperature:</td>
<td class="Table_cell_outline_BR">-20 to 60°C and 20 to 80%RH (no condensation)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Interfaces:</td>
<td class="Table_cell_outline_BR">Select and switch between USB A mass-storage device, USB mini-B communication device class, and mass storage class</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">External sensor:</td>
<td class="Table_cell_outline_BR">A dedicated external sensor can be connected via a connector. (Planned to be released in the future</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Accessories:</td>
<td class="Table_cell_outline_BR">A set of 1.7m long black and red lead wires with alligator clips for generation and measurement, six alkaline AA batteries, R1 1/4” – 1/8” NPT female thread x 1, ferrite core x 2, R 1/4” – 1/4” NPT female thread x 1, accessory case, instruction manual (CD), startup guide, shoulder strap</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-ca700-pressure-alibratr/">Yokogawa CA700 Pressure Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/yokogawa-ca700-pressure-alibratr/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Yokogawa CA330 RTD Process Calibrator</title>
		<link>https://rapid-tech.com.au/yokogawa-ca330-rtd-process-calibrator/</link>
					<comments>https://rapid-tech.com.au/yokogawa-ca330-rtd-process-calibrator/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Wed, 21 Dec 2016 18:53:05 +0000</pubDate>
				<guid isPermaLink="false">http://rapid-tech.com.au/?post_type=product&#038;p=4568</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/10/Yokogawa-Logo-Medium.jpg"><img class="alignnone size-full wp-image-5623" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/Yokogawa-Logo-Medium.jpg" alt="" width="250" height="50" /></a></p>
<p>&#160;</p>
<p><a target="_blank" href="https://mymeter.com.au/product/yokogawa-ca330-rtd-process-calibrator/" rel="noopener"><img class="alignnone size-full wp-image-17843" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/BUY-NOW-form-My-Meter-e1620004827208.png" alt="Buy now form My Meter" width="220" height="55" /></a></p>
<p>The Yokogawa CA330 RTD simulate model corresponds to 14 types of RTD for sourcing. It achieves the high basic accuracy of 0.3°C (typical of type PT100), twice better than the previous model which enables it to operate a high reliable test. CA330 can measure the output of RTD like a thermometer.</p>
<h5 class="contents"><strong>Features:</strong></h5>
<div id="fnb_features" class="featuresList">
<ul class="firstList">
<li>Corresponds to 14 types of RTD standard (JIS/IEC/GOST R)</li>
<li>Sub display displays value of resistance source and span%</li>
<li>Various types of source pattern such as step sweep/ linear sweep/ manual step/ span check</li>
<li>Corresponds to 2, 3, 4 wire &#38; realizes RTD simulation</li>
<li>Operating temperature range from -10°C to 55°C</li>
<li>Dimension is 90mm (W) x 192mm (H) x 42mm (D)</li>
<li>EN61010-1 / EN61010-2-030 safety standard</li>
<li>Segment LCD display and LED backlight</li>
</ul>
<p><iframe src="https://www.youtube.com/embed/olCYMizYWjc" width="560" height="315" frameborder="0" allowfullscreen="allowfullscreen"></iframe></p>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2016/12/Yokogawa-CA300-Series-Datasheet.pdf" rel="noopener">Yokogawa CA300 series Datasheet</a></span></span></h5>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg"><img class="alignnone size-full wp-image-5776" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg" alt="" width="200" height="186" /></a><a href="https://mymeter.com.au/product/yokogawa-ca330-rtd-process-calibrator/"></a></p>
</div>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-ca330-rtd-process-calibrator/">Yokogawa CA330 RTD Process Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Yokogawa CA330 is a high RTD portable handheld calibrator used to inspect and maintain the accuracy of control devices such as temperature controllers, temperature transmitters, temperature sensors and other process devices which are used in process plants, industry machinery, and manufacturing.</p>
<p>The Yokogawa CA330 is a dedicated process calibrator which is capable of performing inspections and calibrations of RTDs. With a high accuracy of ±0.3℃ which is top class as a handy type to source resistance output and measure output of sensors. It not only corresponds to JIS standard and IEC standard thermocouples, but corresponds to GOST-R standard also. It corresponds to inspection and calibration with the summary of 14 types of RTD following the standards.</p>
<div id="Accordion1" class="ui-accordion ui-widget ui-helper-reset">
<div id="ui-accordion-Accordion1-panel-1" class="ui-accordion-content ui-helper-reset ui-widget-content ui-corner-bottom ui-accordion-content-active">
<table id="Source_Specs2">
<tbody>
<tr>
<td class="Table_Green_Background_BLRT" colspan="4"><strong>Yokogawa CA310 Calibrator Specifications:</strong></td>
</tr>
<tr>
<td class="Table_Blue_Background_BLR"><strong>RTD</strong></td>
<td class="Table_Blue_Background_BR"><strong>Coefficient</strong></td>
<td class="Table_Blue_Background_BR"><strong>Source/Meas. Temp.</strong></td>
<td class="Table_Blue_Background_BR"><strong>Source/Meas. Accuracy</strong></td>
<td class="Table_Blue_Background_BR"><strong>Excitation Current</strong></td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">PT100</td>
<td class="Table_cell_outline_BR">3851</td>
<td class="Table_cell_outline_BR">-200.0°C ≤ t &lt; 0.0°C</td>
<td class="Table_cell_outline_BR">0.3V</td>
<td class="Table_cell_outline_BR">0.1-3mA</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">PT100</td>
<td class="Table_cell_outline_BR">3851</td>
<td class="Table_cell_outline_BR">0.0‹C ≤ t ≤ +800.0‹C</td>
<td class="Table_cell_outline_BR">0.3+tx0.033%</td>
<td class="Table_cell_outline_BR">0.1-3mA</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">PT100</td>
<td class="Table_cell_outline_BR">3850</td>
<td class="Table_cell_outline_BR">-200.0°C ≤ t &lt; 0.0°C</td>
<td class="Table_cell_outline_BR">0.3</td>
<td class="Table_cell_outline_BR">0.1-3mA</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">PT100</td>
<td class="Table_cell_outline_BR">3850</td>
<td class="Table_cell_outline_BR">0.0°C ≤ t ≤ +630.0°C</td>
<td class="Table_cell_outline_BR">0.3+tx0.033%</td>
<td class="Table_cell_outline_BR">0.1-3mA</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">PT100</td>
<td class="Table_cell_outline_BR">3916</td>
<td class="Table_cell_outline_BR">-200.0°C ≤ &lt; 0.0°C</td>
<td class="Table_cell_outline_BR">0.3</td>
<td class="Table_cell_outline_BR">0.1-3mA</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">PT100</td>
<td class="Table_cell_outline_BR">3916</td>
<td class="Table_cell_outline_BR">0.0°C ≤ t ≤ +510.0°C</td>
<td class="Table_cell_outline_BR">0.3+tx0.033%</td>
<td class="Table_cell_outline_BR">0.1-3mA</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">PT100</td>
<td class="Table_cell_outline_BR">3926</td>
<td class="Table_cell_outline_BR">-200.0°C ≤ t &lt; 0.0°C</td>
<td class="Table_cell_outline_BR">0.3</td>
<td class="Table_cell_outline_BR">0.1-3mA</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">PT100</td>
<td class="Table_cell_outline_BR">3926</td>
<td class="Table_cell_outline_BR">0.0°C ≤ t ≤ +510.0°C</td>
<td class="Table_cell_outline_BR">0.3+tx0.033%</td>
<td class="Table_cell_outline_BR">0.1-3mA</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">PT200</td>
<td class="Table_cell_outline_BR">3851</td>
<td class="Table_cell_outline_BR">-200.0°C ≤ t &lt; 0.0°C</td>
<td class="Table_cell_outline_BR">0.3 mV</td>
<td class="Table_cell_outline_BR">0.05-0.8mA</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">PT200</td>
<td class="Table_cell_outline_BR">3851</td>
<td class="Table_cell_outline_BR">0.0°C ≤ t ≤ +630.0°C</td>
<td class="Table_cell_outline_BR">0.3+tx0.050%</td>
<td class="Table_cell_outline_BR">0.05-0.8mA</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">PT500</td>
<td class="Table_cell_outline_BR">3851</td>
<td class="Table_cell_outline_BR">-200.0°C ≤ t &lt; 0.0°C</td>
<td class="Table_cell_outline_BR">0.4</td>
<td class="Table_cell_outline_BR">0.05-0.6mA</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">PT500</td>
<td class="Table_cell_outline_BR">3851</td>
<td class="Table_cell_outline_BR">0.0°C ≤ t ≤ +630.0°C</td>
<td class="Table_cell_outline_BR">0.4+tx0.033%</td>
<td class="Table_cell_outline_BR">0.05-0.6mA</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">PT1000</td>
<td class="Table_cell_outline_BR">3851</td>
<td class="Table_cell_outline_BR">-200.0°C ≤ t &lt; 0.0°C</td>
<td class="Table_cell_outline_BR">0.2</td>
<td class="Table_cell_outline_BR">0.05-0.6mA</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">PT1000</td>
<td class="Table_cell_outline_BR">3851</td>
<td class="Table_cell_outline_BR">0.0°C ≤ t ≤ +630.0°C</td>
<td class="Table_cell_outline_BR">0.2+tx0.033%</td>
<td class="Table_cell_outline_BR">0.05-0.6mA</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Cu10</td>
<td class="Table_cell_outline_BR">427</td>
<td class="Table_cell_outline_BR">-100.0°C ≤ t ≤ +260.0°C</td>
<td class="Table_cell_outline_BR">1.5</td>
<td class="Table_cell_outline_BR">0.1-3mA</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Ni120</td>
<td class="Table_cell_outline_BR">627</td>
<td class="Table_cell_outline_BR">-80.0°C ≤ t ≤ +260.0°C</td>
<td class="Table_cell_outline_BR">0.2</td>
<td class="Table_cell_outline_BR">0.1-3mA</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Extra RTD PT50</td>
<td class="Table_cell_outline_BR">3851</td>
<td class="Table_cell_outline_BR">0.0°C ≤ t ≤ +630.0°C</td>
<td class="Table_cell_outline_BR">1 mV</td>
<td class="Table_cell_outline_BR">0.1-3mA</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Extra RTD PT50</td>
<td class="Table_cell_outline_BR">3851</td>
<td class="Table_cell_outline_BR">-200.0°C ≤ t &lt; 0.0°C</td>
<td class="Table_cell_outline_BR">0.4+tx0.050%</td>
<td class="Table_cell_outline_BR">0.1-3mA</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Extra RTD PT50G</td>
<td class="Table_cell_outline_BR">&#8211;</td>
<td class="Table_cell_outline_BR">-200.0°C ≤ t &lt; 0.0°C</td>
<td class="Table_cell_outline_BR">0.4</td>
<td class="Table_cell_outline_BR">0.1-3mA</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Extra RTD PT50G</td>
<td class="Table_cell_outline_BR">&#8211;</td>
<td class="Table_cell_outline_BR">0.0°C ≤ t ≤ +800.0°C</td>
<td class="Table_cell_outline_BR">0.4+tx0.050%</td>
<td class="Table_cell_outline_BR">0.1-3mA</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Extra RTD PT100G</td>
<td class="Table_cell_outline_BR">&#8211;</td>
<td class="Table_cell_outline_BR">-200.0°C ≤ t &lt; 0.0°C</td>
<td class="Table_cell_outline_BR">0.3</td>
<td class="Table_cell_outline_BR">0.1-3mA</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Extra RTD PT100G</td>
<td class="Table_cell_outline_BR">&#8211;</td>
<td class="Table_cell_outline_BR">0.0°C ≤ t ≤ +630.0°C</td>
<td class="Table_cell_outline_BR">0.3+tx0.033%</td>
<td class="Table_cell_outline_BR">0.1-3mA</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Extra RTD Cu50M</td>
<td class="Table_cell_outline_BR">&#8211;</td>
<td class="Table_cell_outline_BR">-180.0°C ≤ t &lt; 0.0°C</td>
<td class="Table_cell_outline_BR">0.4</td>
<td class="Table_cell_outline_BR">0.1-3mA</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Extra RTD Cu50M</td>
<td class="Table_cell_outline_BR">&#8211;</td>
<td class="Table_cell_outline_BR">0.0°C ≤ t ≤ +200.0°C</td>
<td class="Table_cell_outline_BR">0.4+tx0.050%</td>
<td class="Table_cell_outline_BR">0.1-3mA</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Extra RTD Cu100M</td>
<td class="Table_cell_outline_BR">&#8211;</td>
<td class="Table_cell_outline_BR">-180°0‹C ≤ t &lt; 0.0°C</td>
<td class="Table_cell_outline_BR">0.3</td>
<td class="Table_cell_outline_BR">0.1-3mA</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Extra RTD Cu100M</td>
<td class="Table_cell_outline_BR">&#8211;</td>
<td class="Table_cell_outline_BR">0.0°C ≤ t ≤ +200.0°C</td>
<td class="Table_cell_outline_BR">0.3+tx0.033%</td>
<td class="Table_cell_outline_BR">0.1-3mA</td>
</tr>
<tr>
<td class="Table_Blue_Background_BLR">Range</td>
<td class="Table_Blue_Background_BR">Resolution</td>
<td class="Table_Blue_Background_BR">Source &amp; Meas. Range</td>
<td class="Table_Blue_Background_BR">Source &amp; Meas. Accuracy</td>
<td class="Table_cell_outline_BR">Note</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">5000 Ω</td>
<td class="Table_cell_outline_BR">10 mΩ</td>
<td class="Table_cell_outline_BR">0.00 to 550.00Ω</td>
<td class="Table_cell_outline_BR">0.025% of setting/reading+0.1Ω</td>
<td class="Table_cell_outline_BR">0.1-3mA</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">3000 Ω</td>
<td class="Table_cell_outline_BR">100 mΩ</td>
<td class="Table_cell_outline_BR">0.0 to 3300.0Ω</td>
<td class="Table_cell_outline_BR">0.025% of setting/reading+0.1Ω</td>
<td class="Table_cell_outline_BR">0.1-3mA</td>
</tr>
</tbody>
</table>
</div>
</div>
<div class="line_spc"></div>
<table id="Specifications">
<colgroup>
<col />
<col /></colgroup>
<tbody>
<tr>
<td class="Table_Green_Background_BLR" colspan="2"><strong>Yokogawa CA330 General Specifications:</strong></td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Display:</td>
<td class="Table_cell_outline_BR">Segment LCD</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Backlight:</td>
<td class="Table_cell_outline_BR">LED (Selection of “Constantly ON”, “Constantly OFF” or “Auto off by approx. 2min”)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Battery life:</td>
<td class="Table_cell_outline_BR">50 hours (5V source, load over 10kOhm), 25 hours<br />
(20mA source, load under 5V)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Automatic Power-off:</td>
<td class="Table_cell_outline_BR">Approximately 20 minutes (Can be disabled by setting)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Display Refresh Rate:</td>
<td class="Table_cell_outline_BR">Approx 1 sec.</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Level Setting<br />
Response of generator:</td>
<td class="Table_cell_outline_BR">Approximately 1 second<br />
(from when the output begins to change until when the output level falls within the specified accuracy)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Dimensions:</td>
<td class="Table_cell_outline_BR">Approximately Approx. 90 (W)×192 (H)×42 (D)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Weight:</td>
<td class="Table_cell_outline_BR">Approximately 440 g</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Operating temperature/humidity:</td>
<td class="Table_cell_outline_BR">-10 to 55°C and 20 to 80%RH (no condensation)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Storage temperature:</td>
<td class="Table_cell_outline_BR">-20 to 60°C and 90%RH or less (no condensation</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-ca330-rtd-process-calibrator/">Yokogawa CA330 RTD Process Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/yokogawa-ca330-rtd-process-calibrator/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Yokogawa CA320 Thermocouple Process Calibrator</title>
		<link>https://rapid-tech.com.au/yokogawa-ca320-thermocouple-process-calibrator/</link>
					<comments>https://rapid-tech.com.au/yokogawa-ca320-thermocouple-process-calibrator/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 20 Dec 2016 20:10:45 +0000</pubDate>
				<guid isPermaLink="false">http://rapid-tech.com.au/?post_type=product&#038;p=4564</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/10/Yokogawa-Logo-Medium.jpg"><img class="alignnone size-full wp-image-5623" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/Yokogawa-Logo-Medium.jpg" alt="" width="250" height="50" /></a></p>
<p>&#160;</p>
<p><a target="_blank" href="https://mymeter.com.au/product/yokogawa-ca320-thermocouple-process-calibrator/" rel="noopener"><img class="alignnone size-full wp-image-17843" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/BUY-NOW-form-My-Meter-e1620004827208.png" alt="Buy now form My Meter" width="220" height="55" /></a></p>
<p>The Yokogawa CA320 is a dedicated process calibrator which is capable in performing inspections and calibrations of thermocouples. It has an accuracy of ±0.5℃ error and is able to source thermocouple output and measure output of sensors. It not only corresponds to JIS standard and IEC standard thermocouples, but corresponds to ASTM standard and GOST-R standard too. It corresponds to inspection and calibration with the summary of 16 types of thermocouples following the standards.</p>
<h4>Key features</h4>
<ul>
<li>Easy-to-use, high-accuracy temperature calibrator</li>
<li>Thermocouple Calibrator (16 types of thermocouples)</li>
<li>Corresponds to various types of source pattern (Step sweep/ Linear sweep/ Manual step/ Span check)</li>
<li>Measures TC sensor output as a thermometer</li>
<li>RTD calibrator</li>
</ul>
<p><iframe src="https://www.youtube.com/embed/olCYMizYWjc" width="560" height="315" frameborder="0" allowfullscreen="allowfullscreen"></iframe></p>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2016/12/Yokogawa-CA300-Series-Datasheet.pdf" rel="noopener">Yokogawa CA300 series Datasheet</a></span></span></h5>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg"><img class="alignnone size-full wp-image-5776" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg" alt="" width="200" height="186" /></a><a href="hhttps://mymeter.com.au/product/ht-instruments-flashmeter-rugged-digital-multimeter/"></a></p>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-ca320-thermocouple-process-calibrator/">Yokogawa CA320 Thermocouple Process Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="contents">The Yokogawa CA320 is a Thermocouple calibrator and is a high accuracy source and measure portable handheld calibrator used to inspect and maintain the accuracy of control devices such as temperature controllers, temperature transmitters, temperature sensors and other process devices which are used in process plants, industry machinery and manufacturing. It provides an ergonomic and friendly user-interface making it easy to use. The Yokogawa CA320 thermocouple Simulate model corresponds to 16 types of TC for sourcing. It achieves the high basic accuracy of 0.5°C (typical of type K), three times better than the previous model which enables it to operate a highly reliable test. Additionally, the difference of temperature between objects can be compensated, by using external RJ sensor or a compensating lead wire. The Yokogawa CA320 can measure the output of TC like a thermometer.</div>
<h4 class="contents">Yokogawa CA320 Features:</h4>
<div id="fnb_features" class="featuresList">
<ul class="firstList">
<li>Corresponds to 16 types of TC standard (JIS/IEC/DIN/ASTM/GOST R)</li>
<li>Sub display displays value of voltage source and span%</li>
<li>Various types of source pattern such as step sweep/ linear sweep/ manual step/ span check</li>
<li>Corresponds to other TC types by mV source function</li>
<li>Operating temperature range from -10°C to 55°C</li>
<li>Dimension is 90mm (W) x 192mm (H) x 42mm (D)</li>
<li>EN61010-1 / EN61010-2-030 safety standard</li>
<li>Segment LCD display and LED backlight</li>
</ul>
<table id="Source_Specs">
<colgroup>
<col />
<col />
<col />
<col /></colgroup>
<tbody>
<tr>
<td class="Table_Green_Background_BLRT" colspan="4"><strong>Yokogawa CA320 Calibrator Specifications:</strong></td>
</tr>
<tr>
<td class="Table_Blue_Background_BLR"><strong>DCV Range</strong></td>
<td class="Table_Blue_Background_BR"><strong>Source Range</strong></td>
<td class="Table_Blue_Background_BR"><strong>Accuracy</strong></td>
<td class="Table_Blue_Background_BR"><strong>Resolution</strong></td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">90 mV</td>
<td class="Table_cell_outline_BR">-11.000 to ±99.999 mV</td>
<td class="Table_cell_outline_BR">0.015% of setting/reading + 10 μV</td>
<td class="Table_cell_outline_BR">1 μV</td>
</tr>
<tr>
<td class="Table_Blue_Background_BLR">TC</td>
<td class="Table_Blue_Background_BR">Source/Meas. Temp</td>
<td class="Table_Blue_Background_BR">Source Accuracy</td>
<td class="Table_Blue_Background_BR">Meas. Accuracy</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">K</td>
<td class="Table_cell_outline_BR">-200.0°C ≤ t &lt; 0.0°C</td>
<td class="Table_cell_outline_BR">0.5+|t|x0.3%</td>
<td class="Table_cell_outline_BR">0.5+|t|x0.3%</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">K</td>
<td class="Table_cell_outline_BR">0.0°C ≤ t &lt; +500.0°C</td>
<td class="Table_cell_outline_BR">0.5</td>
<td class="Table_cell_outline_BR">0.5</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">K</td>
<td class="Table_cell_outline_BR">+500.0°C ≤ t ≤ +1372.0°C</td>
<td class="Table_cell_outline_BR">0.5+(t-500)x0.03%</td>
<td class="Table_cell_outline_BR">0.5+(t-500)x0.02%</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">E</td>
<td class="Table_cell_outline_BR">-250.0°C ≤ t &lt; -200.0°C</td>
<td class="Table_cell_outline_BR">1.1+(|t|-200)x2.0%</td>
<td class="Table_cell_outline_BR">1.1+(|t|-200)x2.0%</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">E</td>
<td class="Table_cell_outline_BR">-200.0°C ≤ t &lt; 0.0°C</td>
<td class="Table_cell_outline_BR">0.5+|t|x0.3%</td>
<td class="Table_cell_outline_BR">0.5+|t|x0.3%</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">E</td>
<td class="Table_cell_outline_BR">0.0°C ≤ t &lt; +500.0°C</td>
<td class="Table_cell_outline_BR">0.5</td>
<td class="Table_cell_outline_BR">0.5</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">E</td>
<td class="Table_cell_outline_BR">+500.0°C ≤ t ≤ +1000.0°C</td>
<td class="Table_cell_outline_BR">0.5+(t-500)x0.02%</td>
<td class="Table_cell_outline_BR">0.5+(t-500)x0.02%</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">J</td>
<td class="Table_cell_outline_BR">-210.0°C ≤ t &lt; 0.0°C</td>
<td class="Table_cell_outline_BR">0.5+|t|x0.3%</td>
<td class="Table_cell_outline_BR">0.5+|t|x0.3%</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">J</td>
<td class="Table_cell_outline_BR">0.0°C ≤ t ≤ +1200.0°C</td>
<td class="Table_cell_outline_BR">0.5+tx0.02%</td>
<td class="Table_cell_outline_BR">0.5+tx0.02%</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">T</td>
<td class="Table_cell_outline_BR">-250.0°C ≤ t &lt; -200.0°C</td>
<td class="Table_cell_outline_BR">1.1+(|t|-200)x2.5%</td>
<td class="Table_cell_outline_BR">1.1+(|t|-200)x2.5%</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">T</td>
<td class="Table_cell_outline_BR">-200.0°C ≤ t &lt; 0.0°C</td>
<td class="Table_cell_outline_BR">0.5+|t|x0.3%</td>
<td class="Table_cell_outline_BR">0.5+|t|x0.3%</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">T</td>
<td class="Table_cell_outline_BR">0.0°C ≤ t ≤ +400.0°C</td>
<td class="Table_cell_outline_BR">0.5</td>
<td class="Table_cell_outline_BR">0.5</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">N</td>
<td class="Table_cell_outline_BR">-200.0°C ≤ t &lt; 0.0°C</td>
<td class="Table_cell_outline_BR">0.6+|t|x0.4%</td>
<td class="Table_cell_outline_BR">0.6+|t|x0.3%</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">N</td>
<td class="Table_cell_outline_BR">0.0‹C . t . +1300.0‹C</td>
<td class="Table_cell_outline_BR">0.6</td>
<td class="Table_cell_outline_BR">0.6</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">L</td>
<td class="Table_cell_outline_BR">-200.0°C ≤ t &lt; 0.0°C</td>
<td class="Table_cell_outline_BR">0.5+|t|x0.15%</td>
<td class="Table_cell_outline_BR">0.5+|t|x0.15%</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">L</td>
<td class="Table_cell_outline_BR">0.0°C ≤ t ≤ +900.0°C</td>
<td class="Table_cell_outline_BR">0.5</td>
<td class="Table_cell_outline_BR">0.5</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">U</td>
<td class="Table_cell_outline_BR">-200.0°C ≤ t &lt; 0.0°C</td>
<td class="Table_cell_outline_BR">0.5+|t|x0.2%</td>
<td class="Table_cell_outline_BR">0.5+|t|x0.2%</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">U</td>
<td class="Table_cell_outline_BR">0.0°C ≤ t ≤ +600.0°C</td>
<td class="Table_cell_outline_BR">0.5</td>
<td class="Table_cell_outline_BR">0.5</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">R</td>
<td class="Table_cell_outline_BR">-20.0°C ≤ t &lt; 0.0°C</td>
<td class="Table_cell_outline_BR">2.0</td>
<td class="Table_cell_outline_BR">2.0</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">R</td>
<td class="Table_cell_outline_BR">0.0°C ≤ t &lt; +100.0°C</td>
<td class="Table_cell_outline_BR">2.0</td>
<td class="Table_cell_outline_BR">1.4</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">R</td>
<td class="Table_cell_outline_BR">+100.0°C ≤ t ≤ +1767.0°C</td>
<td class="Table_cell_outline_BR">1.4</td>
<td class="Table_cell_outline_BR">1.4</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">S</td>
<td class="Table_cell_outline_BR">-20.0°C ≤ t &lt; 0.0°C</td>
<td class="Table_cell_outline_BR">2.0</td>
<td class="Table_cell_outline_BR">2.0</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">S</td>
<td class="Table_cell_outline_BR">0.0°C ≤ t &lt; +100.0°C</td>
<td class="Table_cell_outline_BR">2.0</td>
<td class="Table_cell_outline_BR">1.4</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">S</td>
<td class="Table_cell_outline_BR">+100.0°C ≤ t ≤ +1768.0 °C</td>
<td class="Table_cell_outline_BR">1.4</td>
<td class="Table_cell_outline_BR">1.4</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">B</td>
<td class="Table_cell_outline_BR">+600.0°C ≤ t &lt; +800.0°C</td>
<td class="Table_cell_outline_BR">1.2</td>
<td class="Table_cell_outline_BR">1.5</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">B</td>
<td class="Table_cell_outline_BR">+800.0°C ≤ t &lt; +1000.0°C</td>
<td class="Table_cell_outline_BR">1.0</td>
<td class="Table_cell_outline_BR">1.2</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">B</td>
<td class="Table_cell_outline_BR">+1000.0°C ≤ t ≤ +1820.0°C</td>
<td class="Table_cell_outline_BR">1.0</td>
<td class="Table_cell_outline_BR">1.1</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">C</td>
<td class="Table_cell_outline_BR">0.0°C ≤ t &lt; +1000.0°C</td>
<td class="Table_cell_outline_BR">0.8</td>
<td class="Table_cell_outline_BR">0.8</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">C</td>
<td class="Table_cell_outline_BR">+1000.0°C ≤ t ≤ +2315.0 °C</td>
<td class="Table_cell_outline_BR">0.8+(t-1000)x0.06%</td>
<td class="Table_cell_outline_BR">0.8+(t-1000)x0.06%</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">XK</td>
<td class="Table_cell_outline_BR">-200.0°C ≤ t &lt; 0.0°C</td>
<td class="Table_cell_outline_BR">0.4+|t|x0.2%</td>
<td class="Table_cell_outline_BR">0.4+|t|x0.2%</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">XK</td>
<td class="Table_cell_outline_BR">0.0°C ≤ t &lt; +300.0°C</td>
<td class="Table_cell_outline_BR">0.4</td>
<td class="Table_cell_outline_BR">0.4</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">XK</td>
<td class="Table_cell_outline_BR">+300.0°C ≤ t ≤ +800.0°C</td>
<td class="Table_cell_outline_BR">0.5</td>
<td class="Table_cell_outline_BR">0.5</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">A</td>
<td class="Table_cell_outline_BR">0.0°C ≤ t &lt; +1000.0°C</td>
<td class="Table_cell_outline_BR">1.0</td>
<td class="Table_cell_outline_BR">1.0</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">A</td>
<td class="Table_cell_outline_BR">+1000.0°C ≤ t ≤ +2500.0°C</td>
<td class="Table_cell_outline_BR">1.0+(t-1000)x0.06%</td>
<td class="Table_cell_outline_BR">1.0+(t-1000)x0.06%</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Extra TC D(W3Re/W25Re)</td>
<td class="Table_cell_outline_BR">0.0°C ≤ t &lt; +300.0°C</td>
<td class="Table_cell_outline_BR">1.2</td>
<td class="Table_cell_outline_BR">1.2</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Extra TC D(W3Re/W25Re)</td>
<td class="Table_cell_outline_BR">+300.0°C ≤ t &lt; +1500.0°C</td>
<td class="Table_cell_outline_BR">1.4</td>
<td class="Table_cell_outline_BR">1.8</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Extra TC D(W3Re/W25Re)</td>
<td class="Table_cell_outline_BR">+1500.0°C ≤ t ≤ +2315.0°C</td>
<td class="Table_cell_outline_BR">1.8</td>
<td class="Table_cell_outline_BR">2.2</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Extra TC G(W/W26Re)</td>
<td class="Table_cell_outline_BR">+100.0‹C . t &lt; +300.0‹C</td>
<td class="Table_cell_outline_BR">1.4</td>
<td class="Table_cell_outline_BR">1.8</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Extra TC G(W/W26Re)</td>
<td class="Table_cell_outline_BR">+300.0°C ≤ t &lt; +1500.0°C</td>
<td class="Table_cell_outline_BR">1.2</td>
<td class="Table_cell_outline_BR">1.2</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Extra TC G(W/W26Re)</td>
<td class="Table_cell_outline_BR">+1500.0°C ≤ t ≤ +2315.0°C</td>
<td class="Table_cell_outline_BR">1.8</td>
<td class="Table_cell_outline_BR">2.2</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Extra TC PLATINEL II</td>
<td class="Table_cell_outline_BR">0.0°C ≤ t &lt; +100.0°C</td>
<td class="Table_cell_outline_BR">0.6</td>
<td class="Table_cell_outline_BR">1.8</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Extra TC PLATINEL II</td>
<td class="Table_cell_outline_BR">+100.0‹C . t &lt; +1000.0‹C</td>
<td class="Table_cell_outline_BR">0.8</td>
<td class="Table_cell_outline_BR">1.8</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Extra TC PLATINEL II</td>
<td class="Table_cell_outline_BR">+1000.0°C ≤ t ≤ +1395.0°C</td>
<td class="Table_cell_outline_BR">1.0</td>
<td class="Table_cell_outline_BR">2.2</td>
</tr>
</tbody>
</table>
<div class="line_spc"></div>
<table id="Specifications">
<colgroup>
<col />
<col /></colgroup>
<tbody>
<tr>
<td class="Table_Green_Background_BLR" colspan="2">General Specifications</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Display:</td>
<td class="Table_cell_outline_BR">Segment LCD</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Backlight:</td>
<td class="Table_cell_outline_BR">LED (Selection of “Constantly ON”, “Constantly OFF” or “Auto off by approx. 2min”)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Battery life:</td>
<td class="Table_cell_outline_BR">55 hours<br />
(20mA source, load under 5V)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Automatic Power-off:</td>
<td class="Table_cell_outline_BR">Approximately 20 minutes (Can be disabled by setting)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Display Refresh Rate:</td>
<td class="Table_cell_outline_BR">Approx 1 sec.</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Level Setting<br />
Response of generator:</td>
<td class="Table_cell_outline_BR">Approximately 1 second<br />
(from when the output begins to change until when the output level falls within the specified accuracy)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Dimensions:</td>
<td class="Table_cell_outline_BR">Approximately Approx. 90 (W)×192 (H)×42 (D)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Weight:</td>
<td class="Table_cell_outline_BR">Approximately 440 g</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Operating temperature/humidity:</td>
<td class="Table_cell_outline_BR">-10 to 55°C and 20 to 80%RH (no condensation)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Storage temperature:</td>
<td class="Table_cell_outline_BR">-20 to 60°C and 90%RH or less (no condensation</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-ca320-thermocouple-process-calibrator/">Yokogawa CA320 Thermocouple Process Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/yokogawa-ca320-thermocouple-process-calibrator/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Multifunction Process Calibrator &#124; Yokogawa CA310 Volts/mA</title>
		<link>https://rapid-tech.com.au/yokogawa-ca310-voltsma-process-calibrator/</link>
					<comments>https://rapid-tech.com.au/yokogawa-ca310-voltsma-process-calibrator/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 20 Dec 2016 19:10:24 +0000</pubDate>
				<guid isPermaLink="false">http://rapid-tech.com.au/?post_type=product&#038;p=4558</guid>

					<description><![CDATA[<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/10/Yokogawa-Logo-Medium.jpg"><img class="alignnone size-full wp-image-5623" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/Yokogawa-Logo-Medium.jpg" alt="" width="250" height="50" /></a></p>
<p>&#160;</p>
<p><a target="_blank" href="https://mymeter.com.au/product/yokogawa-ca310-volts-ma-process-calibrator/" rel="noopener"><img class="alignnone size-full wp-image-17843" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/BUY-NOW-form-My-Meter-e1620004827208.png" alt="Buy now form My Meter" width="220" height="55" /></a></p>
<p>The Yokogawa CA310 Process Calibrator simultaneously supplies a 24V loop power and measure output signal with an accuracy of accuracy 0.015%. The sub display shows value of voltage source and span %. The CA310 features step sweep, linear sweep, manual step and span check source patterns.</p>
<h3>Features</h3>
<h4>Key features</h4>
<ul>
<li>Calibration of both pressure and temperature transmitters</li>
<li>Measure/source/simulate mA loop parameters</li>
<li>Measure and source mA, Volts DC</li>
<li>Built-in 24 V loop power supply</li>
</ul>
<p><iframe src="https://www.youtube.com/embed/olCYMizYWjc" width="560" height="315" frameborder="0" allowfullscreen="allowfullscreen"></iframe></p>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2016/12/Yokogawa-CA300-Series-Datasheet.pdf" rel="noopener">Y<span style="color: #0000ff;">okogawa CA300 Series Datasheet</span></a></h5>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg"><img class="alignnone size-full wp-image-5776" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg" alt="" width="200" height="186" /></a></p>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-ca310-voltsma-process-calibrator/">Multifunction Process Calibrator | Yokogawa CA310 Volts/mA</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Yokogawa CA310 Multifunction Process Calibrator simultaneously supplies a 24V loop power and measure output signal with an accuracy of accuracy 0.015%. The sub display shows value of voltage source and span %. The CA310 features step sweep, linear sweep, manual step and span check source patterns.</p>
<h3>Yokogawa CA310 Features:</h3>
<ul>
<li>CA310 Volt mA Calibrator:
<ul>
<li>0.015% basic accuracy</li>
<li>20mA SIMULATE (SINK) function</li>
<li>HART/BRAIN comm. resistance (250Ω) embedded</li>
<li>Segment LCD display</li>
</ul>
</li>
</ul>
<div class="contents">The Yokogawa CA310 is a Volt mA calibrator. The CA300 series process calibrator is a high accuracy source and measure portable handheld calibrator used to inspect and maintain the accuracy of control devices such as temperature controllers, temperature transmitters, temperature sensors and other process devices which are used in process plants, industry machinery and manufacturing. The CA310 voltage and current simulate model is capable to execute a loop check by simulating a transmitter, sinking the current signal from the external source. It achieves the high accuracy 0.015% of setting to source 4mA to 20mA. DC mA signals can be measured by supplying power to the transmitter from a 24V DC power supply. DC mA measurement and zero-point check can be performed with an accuracy of 0.015% of reading. A 250 ohm resistor for HART and BRAIN communication is included in this calibrator so there is no need to attach an external resistor when connecting to a handy terminal.</div>
<div id="fnb_features" class="featuresList">
<ul class="firstList">
<li>Sub display displays span% of the source value</li>
<li>Various types of source pattern such as step sweep/ linear sweep/ manual step/ span check</li>
<li>Operating temperature range from -10°C to 55°C</li>
<li>Dimension of 90mm (W) x 192mm (H) x 42mm (D)</li>
<li>EN61010-1 / EN61010-2-030 safety standard</li>
<li>Segment LCD display and LED backlight</li>
</ul>
</div>
<p>&nbsp;</p>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-ca310-voltsma-process-calibrator/">Multifunction Process Calibrator | Yokogawa CA310 Volts/mA</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/yokogawa-ca310-voltsma-process-calibrator/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Yokogawa CA450 Process Multimeter</title>
		<link>https://rapid-tech.com.au/yokogawa-ca450-process-multimeter/</link>
					<comments>https://rapid-tech.com.au/yokogawa-ca450-process-multimeter/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Sun, 14 Feb 2016 15:12:23 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/yokogawa-ca450-processing-multimeter/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-5623" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/Yokogawa-Logo-Medium.jpg" alt="" width="250" height="50" /></p>
<p><a target="_blank" href="https://mymeter.com.au/product/yokogawa-ca450-process-multimeter/" rel="noopener"><img class="alignnone size-full wp-image-17843" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/BUY-NOW-form-My-Meter-e1620004827208.png" alt="Buy now form My Meter" width="220" height="55" /></a></p>
<h4>CA450 Process Multimeter / Calibrator<br />
Loop Power and 4 to 20 mA Output function in a DMM</h4>
<p>From daily inspection to troubleshooting of measurement instruments— all in a single unit! ideal for checking the operation of field devices and maintenance of electrical equipment. Similar to the Fluke 787 &#38; Fluke 789.</p>
<p>The Yokogawa CA450 Process Multimeter is a portable test instrument to combine a digital RMS multimeter and a loop calibrator to give process technicians the same functionality in one tool. The Yokogawa CA450 provides 24-Volt loop power, reducing the need for carrying a separate power supply when performing transmitter testing. And with its built-in, selectable 250-Ohm Hart resistor, it also eliminates the need for a separate resistor. Process technicians can now do the same job while carrying less equipment</p>
<p><strong>Product Tags:</strong> #Process Multimeter #Yokogawa CA450 #Alternative to Fluke 789</p>
<h4>Applications</h4>
<table id="Advanced_Functions">
<colgroup>
<col />
<col /></colgroup>
<tbody>
<tr>
<td>
<ul>
<li>Operating check, adjustment for valve and positioner</li>
<li>4–20 mA step/Auto-step/sweep output applications</li>
<li>AC/DC current measurement (sensor mode)</li>
</ul>
</td>
<td>
<ul>
<li>2-wire transmitter loop check (mA LOOP POWER) and simulator (20 mA SINK)</li>
<li>Power supply peak-to-peak measurement</li>
<li>Panel meter inspection</li>
</ul>
</td>
</tr>
</tbody>
</table>
<h4><img class="alignnone size-full wp-image-5149" src="http://rapid-tech.com.au/wp-content/uploads/2017/05/pdf_sml-1.png" alt="pdf_sml" width="40" height="40" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2016/02/Yokogawa-CA450-Datasheet.pdf" rel="noopener">Yokogawa CA450 Datasheet</a></span></span></h4>
<h4><a href="http://rapid-tech.com.au/wp-content/uploads/2017/05/pdf_sml-1.png"><img class="alignnone size-full wp-image-5149" src="http://rapid-tech.com.au/wp-content/uploads/2017/05/pdf_sml-1.png" alt="pdf_sml" width="40" height="40" /></a>    <span style="color: #0000ff;"><a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2016/02/Yokogawa-CA450-User-Manual.pdf" rel="noopener">Yokogawa CA450 User Manual</a></span></h4>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2017/05/pdf_sml-1.png"><img class="alignnone size-full wp-image-5149" src="https://rapid-tech.com.au/wp-content/uploads/2017/05/pdf_sml-1.png" alt="" width="40" height="40" /></a>    <span style="color: #0000ff;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2016/02/CA450-Application-Note.pdf" rel="noopener">Yokogawa CA450 Application Note</a></span></h4>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg"><img class="alignnone size-full wp-image-5776" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg" alt="" width="200" height="186" /></a></p>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-ca450-process-multimeter/">Yokogawa CA450 Process Multimeter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3><strong><b>Yokogawa CA450 Process Multimeter</b> Features:</strong></h3>
<p><strong>Loop Power and 4 to 20 mA Output function in a DMM</strong></p>
<ul>
<li>Loop check functions</li>
<li>Simultaneous 24 V loop power and mA measurement</li>
<li>HART/BRAIN mode setting with loop power (Adds 250 ohm resistance internally</li>
<li>Generation functions<br />
&#8211; SIMULATE (SINK) function simulates transmitters– 4-20 mA span/step/auto-step/sweep output</li>
<li>Measurement functions</li>
<li>&#8211; High accuracy signal measurement:– DC mA 0.05%/30.000 mA– Handheld DMM function– Peak Hold function for the peak voltage measurement of DCS power supply– Dedicated sensor modes for direct reading of many sensor signal types</li>
<li>Enhanced Safety—helps eliminate electric shocks<br />
– Current terminal shutter prevents incorrect connections<br />
– 1 A or more of AC/DC current can be read directly using the optional clamp probe and scaling in SENSOR mode.*1<br />
– Measurement categories 600 V CAT. IV, 1000 V CAT. III</li>
<li>Linking with a PC</li>
<li>DMM Communication Package can be used to save and</li>
<li>Loop check function</li>
<li>Span generation function</li>
<li>Step generation function</li>
<li>Sweep generation function</li>
<li>AC/DC Current measurement (SENSOR mode</li>
<li>Transmitter simulation function</li>
<li>Similar to the Fluke 787 &amp; Fluke 789</li>
</ul>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2016/02/CA450-Banner-1.jpg"><img decoding="async" class="alignnone size-full wp-image-5779" src="https://rapid-tech.com.au/wp-content/uploads/2016/02/CA450-Banner-1.jpg" alt="" width="1086" height="346" srcset="https://rapid-tech.com.au/wp-content/uploads/2016/02/CA450-Banner-1.jpg 1086w, https://rapid-tech.com.au/wp-content/uploads/2016/02/CA450-Banner-1-300x96.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2016/02/CA450-Banner-1-600x191.jpg 600w, https://rapid-tech.com.au/wp-content/uploads/2016/02/CA450-Banner-1-768x245.jpg 768w, https://rapid-tech.com.au/wp-content/uploads/2016/02/CA450-Banner-1-1024x326.jpg 1024w" sizes="(max-width: 1086px) 100vw, 1086px" /></a></p>
<h3>Yokogawa CA450 Process Multimeter Specifications:</h3>
<table class="specsalt">
<tbody>
<tr>
<td class="specstop"><strong>Specifications</strong></td>
<td class="specstop"><strong>Accuracy and Range</strong></td>
</tr>
<tr>
<td class="specs4">DC voltage</td>
<td class="specs5">0.09% rdg+1 dgt6</p>
<p>00.0 mV to 1000 V</td>
</tr>
<tr>
<td class="specs4">Current voltage (true rms value)</td>
<td class="specs5">0.5% rdg+5 dgt</p>
<p>600.0 mV to 1000 V</p>
<p>(45 to 500 Hz)</td>
</tr>
<tr>
<td class="specs4" rowspan="2">DC current (mA)</td>
<td class="specs5">0.05% rdg+2 dgt/30.000 mA</td>
</tr>
<tr>
<td class="specs5">0.05% rdg+2 dgt/100.00 mA</td>
</tr>
<tr>
<td class="specs4">Impedance</td>
<td class="specs5">0.2% rdg + 1 dgt</p>
<p>600.0Ω to 60.00 MΩ</td>
</tr>
<tr>
<td class="specs4">Frequency</td>
<td class="specs5">0.005% rdg + 1 dgt199.99 Hz to 19.999 kHz</td>
</tr>
<tr>
<td class="specs4"></td>
<td class="specs5"><img decoding="async" src="https://www.testequipmentdepot.com/yokogawa/images/checkmark.gif" alt="" width="12" height="13" /></td>
</tr>
<tr>
<td class="specs4">Diode test</td>
<td class="specs5">1% rdg + 2 dgt</p>
<p>2.000 V</td>
</tr>
<tr>
<td class="specs4">Continuity</td>
<td class="specs5">Beeps under 50 ±30Ω</td>
</tr>
<tr>
<td class="specs4">Display update rate (times/sec.)</td>
<td class="specs5">2.5 to 5</td>
</tr>
<tr>
<td class="specs4">Data hold</td>
<td class="specs5"><img decoding="async" src="https://www.testequipmentdepot.com/yokogawa/images/checkmark.gif" alt="" width="12" height="13" /></td>
</tr>
<tr>
<td class="specs4">Peak hold (DCV)</td>
<td class="specs5"><img decoding="async" src="https://www.testequipmentdepot.com/yokogawa/images/checkmark.gif" alt="" width="12" height="13" /></td>
</tr>
<tr>
<td class="specs4">Standard deviation</td>
<td class="specs5"><img decoding="async" src="https://www.testequipmentdepot.com/yokogawa/images/checkmark.gif" alt="" width="12" height="13" /></td>
</tr>
<tr>
<td class="specs4">Max/min</td>
<td class="specs5"><img decoding="async" src="https://www.testequipmentdepot.com/yokogawa/images/checkmark.gif" alt="" width="12" height="13" /></td>
</tr>
<tr>
<td class="specs4">DC current (mA)</td>
<td class="specs5">0.05% to span of 20.000m</p>
<p>A0.001mA to 25.000mA, Max. load 28 V</td>
</tr>
<tr>
<td class="specs4">Simulate (Sink)</td>
<td class="specs5">0.05% to span of 20.000mA</p>
<p>0.001mA to 25.000mA, Ext. power 15 to 48 Vdc</td>
</tr>
<tr>
<td class="specs4">Loop power function</td>
<td class="specs5">24V with 250Ω resistance ON/OFF function</td>
</tr>
<tr>
<td class="specs4">Auto-step</td>
<td class="specs5"><img decoding="async" src="https://www.testequipmentdepot.com/yokogawa/images/checkmark.gif" alt="" width="12" height="13" /></td>
</tr>
<tr>
<td class="specs4">Auto-sweep</td>
<td class="specs5"><img decoding="async" src="https://www.testequipmentdepot.com/yokogawa/images/checkmark.gif" alt="" width="12" height="13" /></td>
</tr>
<tr>
<td class="specs4">Step (manual)</td>
<td class="specs5"><img decoding="async" src="https://www.testequipmentdepot.com/yokogawa/images/checkmark.gif" alt="" width="12" height="13" /></td>
</tr>
<tr>
<td class="specs4">Safety standard</td>
<td class="specs5">EN61010/1000VCAT III, 600VCAT IV</td>
</tr>
<tr>
<td class="specs4">Communication (optional)</td>
<td class="specs5">IR-USB</td>
</tr>
<tr>
<td class="specs4">Backlight</td>
<td class="specs5"><img decoding="async" src="https://www.testequipmentdepot.com/yokogawa/images/checkmark.gif" alt="" width="12" height="13" /></td>
</tr>
<tr>
<td class="specs4"></td>
</tr>
</tbody>
</table>
<div class="row"  id="row-1261086550">

	<div id="col-665627363" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<h3 style="text-align: left;"><strong>CA450</strong></h3>
<h3 style="text-align: left;"><strong>Current terminal shutter</strong></h3>
<h3 style="text-align: left;"><strong>prevents incorrect </strong></h3>
<h3 style="text-align: left;"><strong>lead connections</strong></h3>
		</div>
					</div>

	

	<div id="col-1212541070" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<a href="https://rapid-tech.com.au/wp-content/uploads/2016/02/CA450-Shutters.jpg"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-5780" src="https://rapid-tech.com.au/wp-content/uploads/2016/02/CA450-Shutters.jpg" alt="" width="517" height="257" srcset="https://rapid-tech.com.au/wp-content/uploads/2016/02/CA450-Shutters.jpg 517w, https://rapid-tech.com.au/wp-content/uploads/2016/02/CA450-Shutters-300x149.jpg 300w" sizes="auto, (max-width: 517px) 100vw, 517px" /></a></p>
		</div>
					</div>

	
</div>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-ca450-process-multimeter/">Yokogawa CA450 Process Multimeter</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/yokogawa-ca450-process-multimeter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Yokogawa CA150 Handy Multifunction Calibrator</title>
		<link>https://rapid-tech.com.au/yokogawa-ca150-handy-multifunction-calibrator/</link>
					<comments>https://rapid-tech.com.au/yokogawa-ca150-handy-multifunction-calibrator/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Sun, 14 Feb 2016 15:12:21 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/yokogawa-ca150-handy-multifunction-calibrator/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-33" src="http://rapid-tech.com.au/wp-content/uploads/2015/12/Yokogawa_logo_sml.jpg" alt="Yokogawa_logo_sml" width="110" height="20" /></p>
<p>The Yokogawa CA150 Multi-functional and high-precision calibrator that can be used to calibrate and test industrial process devices and various electronics equipment.</p>
<h4>Features:</h4>
<ul>
<li><b>Vertical hand-held calibrator</b><br />
Easy-to-hold vertical type is designed to make it intuitively easy to operate, as individual functions are accessed directly by pressing assigned keys. Using the main unit body case, you can hang the CA150 to your body or a handrail to keep<br />
it handy.</li>
<li><b>Simultaneous signal source and measurement operations at the<br />
same time</b><br />
In conventional calibration applications, multiple devices such as a standard generator, adjustable resistor and multimeter were required. Now with a single CA150 unit, it is possible to perform operation checks at regular inspection and maintenance of thermocouples, RTD's and instruments, as well as maintenance and equipment diagnosis of process devices such as transmitters, thermostats and signal converters.</li>
</ul>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2016/02/CA150-Specification-Sheet.pdf" rel="noopener noreferrer">CA150 Specification Sheet</a></span></span></h5>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg"><img class="alignnone size-full wp-image-5776" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg" alt="" width="200" height="186" /></a></p>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-ca150-handy-multifunction-calibrator/">Yokogawa CA150 Handy Multifunction Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Yokogawa CA150 Calibrator is a comprehensive source and measure instrument for your calibration and equipment checking needs at maintenance sites. The CA150 can simultaneously source and measure voltage, current, resistance, TC (Thermocouple), RTD (Resistance Temperature Detector) and pulse signals, all in a single unit. In addition, direct keys for function selection make operation smoother and prevent incorrect measurement by erroneous operations</p>
<p>The CA150 Handy Cal’s memory is capable of storing up to one hundred (100) <strong>data</strong> items, storage date/time, (source/measurement) functions, ranges and generated values/measured values can be stored. It can also save/load <strong>setting conditions</strong>. Up to 21 data items can be stored. Settings for (source/measurement) functions, ranges, generated values/measured values as well as setting mode conditions. Stored data can be checked on the display of the main unit as well as via communication.</p>
<h4>Yokogawa CA150 Applications:</h4>
<table id="Advanced_Functions">
<tbody>
<tr>
<td>
<ul>
<li class="first-child">Check flowmeter pulse output and field data</li>
<li class="last-child">Calibration, function check Programmable Controllers</li>
</ul>
</td>
<td>
<ul>
<li class="first-child">Operation check for Yokogawa Pressure Transmitters (4-20 mA)</li>
<li class="last-child">Operation check of Temperature Transmitters</li>
</ul>
</td>
</tr>
</tbody>
</table>
<table id="Specifications">
<tbody>
<tr>
<td class="Table_Green_Background_BLRT" colspan="2">Model: Yokogawa CA150 Calibrator</td>
</tr>
<tr>
<td class="Table_Blue_Background_BLR" colspan="2">Source Unit</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Voltage limiter:</td>
<td class="Table_cell_outline_BR">Approx. 32 V</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Current limiter:</td>
<td class="Table_cell_outline_BR">Approx. 25 mA</td>
</tr>
<tr>
<td class="Table_Blue_Background_BLR" colspan="2">Measurement Unit</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Voltage terminal:</td>
<td class="Table_cell_outline_BR">42 VDC</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Current terminal:</td>
<td class="Table_cell_outline_BR">120 mA</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Loop Power :</td>
<td class="Table_cell_outline_BR">Single 24 VDC power supply, Fuse: 125 mA/250 V</td>
</tr>
<tr>
<td class="Table_Green_Background_BLR" colspan="2">General Specifications</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Battery:</td>
<td class="Table_cell_outline_BR">6 AA size alkaline batteries – dedicated NiMH battery (sold separately)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Battery life:</td>
<td class="Table_cell_outline_BR">Source/measurement<br />
Output of 5 V DC/10 k or more Size AA alkaline batteries<br />
When 6 batteries are used: Approx. 8 hours<br />
When NiMH battery is used: Approx. 10 hours</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">AC adapter :</td>
<td class="Table_cell_outline_BR">100 to 240 VAC, 50/60 Hz, 1.4 A<br />
OUTPUT: 12 VDC, 3 A</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Auto power-off:</td>
<td class="Table_cell_outline_BR">Approx. 10 minutes;</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Insulation resistance:</td>
<td class="Table_cell_outline_BR">Between input terminal and output terminal: 500 VDC, 50 M or more</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Withstand voltage:</td>
<td class="Table_cell_outline_BR">Between measurement terminal and generation terminal: 350 VAC, 1 minute</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Dimensions:</td>
<td class="Table_cell_outline_BR">Approx. 251 x 124 x 70 mm</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Weight:</td>
<td class="Table_cell_outline_BR">Approx. 1000 g (with Batteries)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Operating temperature:</td>
<td class="Table_cell_outline_BR">0 to 40°C, 20 to 80%RH (no condensation)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Storage temperature:</td>
<td class="Table_cell_outline_BR">–20 to 60°C 90%RH or less (no condensation)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Communication:</td>
<td class="Table_cell_outline_BR">Serial interface: RS232 D-Sub 9-pin connector</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">Safety:</td>
<td class="Table_cell_outline_BR">EN61010-1, EN61010-2-030, UL61010-1<br />
CAN/CSA, C22.2 No.61010-1</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">EMC:</td>
<td class="Table_cell_outline_BR">EN 61326-1 Class B;EN 55011 Class B Group1<br />
EN 61000-3-2; EN 61000-3-3</td>
</tr>
</tbody>
</table>
<table id="Source_Specs">
<tbody>
<tr>
<td class="Table_Green_Background_BLRT" colspan="4">Model: Yokogawa CA150 Calibrator</td>
</tr>
<tr>
<td class="Table_Blue_Background_BLR">DCV Range</td>
<td class="Table_Blue_Background_BR">Source Range</td>
<td class="Table_Blue_Background_BR">Accuracy</td>
<td class="Table_Blue_Background_BR">Resolution</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">100 mV</td>
<td class="Table_cell_outline_BR">0 to ±110.000 mV</td>
<td class="Table_cell_outline_BR">±(0.02% +10 μV)</td>
<td class="Table_cell_outline_BR">1 μV</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">1 V</td>
<td class="Table_cell_outline_BR">0 to ±1.10000 V</td>
<td class="Table_cell_outline_BR">±(0.02% +0.05 mV)</td>
<td class="Table_cell_outline_BR">10 μV</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">10 V</td>
<td class="Table_cell_outline_BR">0 to ±11.0000 V</td>
<td class="Table_cell_outline_BR">±(0.02% +0.5 mV)</td>
<td class="Table_cell_outline_BR">0.1 mV</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">30 V</td>
<td class="Table_cell_outline_BR">0 to ±30.00</td>
<td class="Table_cell_outline_BR">±(0.02% +10 mV)</td>
<td class="Table_cell_outline_BR">10 mV</td>
</tr>
<tr>
<td class="Table_Blue_Background_BLR">DCmA Range</td>
<td class="Table_Blue_Background_BR">Source Range</td>
<td class="Table_Blue_Background_BR">Accuracy</td>
<td class="Table_Blue_Background_BR">Resolution</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">20 mA</td>
<td class="Table_cell_outline_BR">0 to +22.000 mA</td>
<td class="Table_cell_outline_BR">±(0.025% +3 μA)</td>
<td class="Table_cell_outline_BR">1 μA</td>
</tr>
<tr>
<td class="Table_Blue_Background_BLR">mA SINK</td>
<td class="Table_Blue_Background_BR">Source Range</td>
<td class="Table_Blue_Background_BR">Accuracy</td>
<td class="Table_Blue_Background_BR">Resolution</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">20 mA SINK</td>
<td class="Table_cell_outline_BR">0 to -22.000 mA</td>
<td class="Table_cell_outline_BR">±(0.025% +6 μA)</td>
<td class="Table_cell_outline_BR">1 μA</td>
</tr>
<tr>
<td class="Table_Blue_Background_BLR">Resistance Range</td>
<td class="Table_Blue_Background_BR">Source Range</td>
<td class="Table_Blue_Background_BR">Accuracy</td>
<td class="Table_Blue_Background_BR">Resolution</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">500 Ω</td>
<td class="Table_cell_outline_BR">0 to 550.00 Ω</td>
<td class="Table_cell_outline_BR">±(0.02% +0.1 Ω)</td>
<td class="Table_cell_outline_BR">0.01 Ω</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">5 kΩ</td>
<td class="Table_cell_outline_BR">0 to 5.5000 kΩ</td>
<td class="Table_cell_outline_BR">±(0.05% +1.5 Ω)</td>
<td class="Table_cell_outline_BR">0.1 Ω</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">50 kΩ</td>
<td class="Table_cell_outline_BR">0 to 55.000 kΩ</td>
<td class="Table_cell_outline_BR">±(0.1% +50 Ω)</td>
<td class="Table_cell_outline_BR">1 Ω</td>
</tr>
<tr>
<td class="Table_Blue_Background_BLR">RTD Output</td>
<td class="Table_Blue_Background_BR">Source Range</td>
<td class="Table_Blue_Background_BR">Accuracy</td>
<td class="Table_Blue_Background_BR">Resolution</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">PT 100</td>
<td class="Table_cell_outline_BR">-200.0 to 850.0°C</td>
<td class="Table_cell_outline_BR">±(0.025% +0.3°C)</td>
<td class="Table_cell_outline_BR">0.1°C</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">JPT 100</td>
<td class="Table_cell_outline_BR">-200.0 to 500.0°C</td>
<td class="Table_cell_outline_BR">±(0.025% +0.3°C)</td>
<td class="Table_cell_outline_BR">0.1°C</td>
</tr>
<tr>
<td class="Table_Blue_Background_BLR">TC Output</td>
<td class="Table_Blue_Background_BR">Source Range</td>
<td class="Table_Blue_Background_BR">Accuracy</td>
<td class="Table_Blue_Background_BR">Resolution</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR" rowspan="2">K</td>
<td class="Table_cell_outline_BR">200.0 to 1372.0°C</td>
<td class="Table_cell_outline_BR">±(0.02% +0.5°C)</td>
<td class="Table_cell_outline_BRm" rowspan="2">0.1°C</td>
</tr>
<tr>
<td class="Table_cell_outline_BR">-200.0 to -100.0°C</td>
<td class="Table_cell_outline_BR">±(0.02% +0.8°C)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR" rowspan="2">E</td>
<td class="Table_cell_outline_BR">-200.0 to 1000.0°C</td>
<td class="Table_cell_outline_BR">±(0.02% +0.4°C)</td>
<td class="Table_cell_outline_BRm" rowspan="2">0.1°C</td>
</tr>
<tr>
<td class="Table_cell_outline_BR">-200.0 to -100.0°C</td>
<td class="Table_cell_outline_BR">±(0.02% +0.6°C)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR" rowspan="2">J</td>
<td class="Table_cell_outline_BR">-200.0 to 1200.0°C</td>
<td class="Table_cell_outline_BR">±(0.02% +0.4°C)</td>
<td class="Table_cell_outline_BRm" rowspan="2">0.1°C</td>
</tr>
<tr>
<td class="Table_cell_outline_BR">-200.0 to -100.0°C</td>
<td class="Table_cell_outline_BR">±(0.02% +0.7°C)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR" rowspan="2">T</td>
<td class="Table_cell_outline_BR">-200.0 to 400.0°C</td>
<td class="Table_cell_outline_BR">±(0.02% +0.5°C)</td>
<td class="Table_cell_outline_BRm" rowspan="2">0.1°C</td>
</tr>
<tr>
<td class="Table_cell_outline_BR">-200.0 to -100.0°C</td>
<td class="Table_cell_outline_BR">±(0.02% +0.8°C)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR" rowspan="2">N</td>
<td class="Table_cell_outline_BR">-200.0 to 1300.0°C</td>
<td class="Table_cell_outline_BR">±(0.02% +0.5°C)</td>
<td class="Table_cell_outline_BRm" rowspan="2">0.1°C</td>
</tr>
<tr>
<td class="Table_cell_outline_BR">-200.0 to 0°C</td>
<td class="Table_cell_outline_BR">±(0.02% +1.0°C)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">L</td>
<td class="Table_cell_outline_BR">-200.0 to 900.0°C</td>
<td class="Table_cell_outline_BR">±(0.02% +0.5°C)</td>
<td class="Table_cell_outline_BRm">0.1°C</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR" rowspan="2">U</td>
<td class="Table_cell_outline_BR">-200.0 to 400.0°C</td>
<td class="Table_cell_outline_BR">±(0.02% +0.5°C)</td>
<td class="Table_cell_outline_BRm" rowspan="2">0.1°C</td>
</tr>
<tr>
<td class="Table_cell_outline_BR">-200.0 to 0°C</td>
<td class="Table_cell_outline_BR">±(0.02% +0.7°C)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR" rowspan="2">R</td>
<td class="Table_cell_outline_BR">0 to 1768°C</td>
<td class="Table_cell_outline_BR">± (0.02% +1.2°C)</td>
<td class="Table_cell_outline_BRm" rowspan="2">0.1°C</td>
</tr>
<tr>
<td class="Table_cell_outline_BR">0 to 100°C</td>
<td class="Table_cell_outline_BR">± (0.02% +2°C)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR" rowspan="2">S</td>
<td class="Table_cell_outline_BR">0 to 1768°C</td>
<td class="Table_cell_outline_BR">(0.02% +1.2°C)</td>
<td class="Table_cell_outline_BRm" rowspan="2">0.1°C</td>
</tr>
<tr>
<td class="Table_cell_outline_BR">0 to 100°C</td>
<td class="Table_cell_outline_BR">± (0.02% +2°C)</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR" rowspan="2">B</td>
<td class="Table_cell_outline_BR">600 to 1820°C</td>
<td class="Table_cell_outline_BR">± (0.02% +1°C)</td>
<td class="Table_cell_outline_BRm" rowspan="2">0.1°C</td>
</tr>
<tr>
<td class="Table_cell_outline_BR">600 to 1000°C</td>
<td class="Table_cell_outline_BR">± (0.02% +1.5°C)</td>
</tr>
<tr>
<td class="Table_Blue_Background_BLR">Hz/Pulse</td>
<td class="Table_Blue_Background_BR">Source Range</td>
<td class="Table_Blue_Background_BR">Accuracy</td>
<td class="Table_Blue_Background_BR">Resolution</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">CPM</td>
<td class="Table_cell_outline_BR">1.0 to 1100.0 CPM</td>
<td class="Table_cell_outline_BR">±0.5 CPM</td>
<td class="Table_cell_outline_BRm">0.1 CPM</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">100 Hz</td>
<td class="Table_cell_outline_BR">1.00 to 110.00 Hz</td>
<td class="Table_cell_outline_BR">±0.05 Hz</td>
<td class="Table_cell_outline_BRm">0.01 Hz</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">1000 Hz</td>
<td class="Table_cell_outline_BR">90.0 to 1100.0 Hz</td>
<td class="Table_cell_outline_BR">±0.5 Hz</td>
<td class="Table_cell_outline_BRm">0.1 Hz</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">10 kHz</td>
<td class="Table_cell_outline_BR">0.9 kHz to 11.0 kHz</td>
<td class="Table_cell_outline_BR">±0.1 kHz</td>
<td class="Table_cell_outline_BR">0.1 kHz</td>
</tr>
<tr>
<td class="Table_Grey_Background_BLR">50 kHz</td>
<td class="Table_cell_outline_BR">9 kHz to 50 kHz</td>
<td class="Table_cell_outline_BR">±1 kHz</td>
<td class="Table_cell_outline_BR">1 kHz</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-ca150-handy-multifunction-calibrator/">Yokogawa CA150 Handy Multifunction Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/yokogawa-ca150-handy-multifunction-calibrator/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Yokogawa CA71 Handy Multifunction Calibrator</title>
		<link>https://rapid-tech.com.au/yokogawa-ca71-handy-multifunction-calibrator/</link>
					<comments>https://rapid-tech.com.au/yokogawa-ca71-handy-multifunction-calibrator/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Sun, 14 Feb 2016 15:12:21 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/yokogawa-ca71-handy-multifunction-calibrator/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-5623" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/Yokogawa-Logo-Medium.jpg" alt="" width="250" height="50" /></p>
<p>&#160;</p>
<p><a target="_blank" href="https://mymeter.com.au/product/yokogawa-ca71-multifunction-calibrator/" rel="noopener"><img class="alignnone size-full wp-image-17843" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/BUY-NOW-form-My-Meter-e1620004827208.png" alt="Buy now form My Meter" width="220" height="55" /></a></p>
<h2>Multi-function, Easy-to-use Handheld Calibrator</h2>
<h4>Multi-functional and high-precision calibrators that can be used to calibrate and test industrial process devices and various electronics equipment.</h4>
<p>Sensors and instruments require a wide variety of operation checks in the field. The Yokgawa CA71, Handy Calibrator, is a small, lightweight, multifunction calibrator that can simultaneously source and measure voltage, current, resistance, TC, RTD, frequency, and pulse signals.</p>
<p>The CA71 is a comprehensive generating / measuring instrument for all your calibration and equipment checking needs at maintenance and production sites, making your task much easier. In addition, The CA71 incorporates a rotary switches for simple handling. Just open the carrying case cover and connect the cables, and you’re ready to take measurements</p>
<h4><strong>Applications </strong></h4>
<table id="Advanced_Functions">
<colgroup>
<col />
<col /></colgroup>
<tbody>
<tr>
<td>
<ul>
<li class="first-child">Maintenance and Preventative Maintenance Applications</li>
<li class="last-child">Production line quality Assurance</li>
</ul>
</td>
<td>
<ul>
<li class="first-child">In the Field Product Calibration</li>
<li class="last-child">Operation check of Temperature Transmitters and Sensor</li>
</ul>
</td>
</tr>
</tbody>
</table>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2016/02/CA71-Specification-Sheet.pdf" rel="noopener">CA71 Specification Sheet</a></span></span></h5>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg"><img class="alignnone size-full wp-image-5776" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/YEW-AUS-DISTRIBUTOR-SMALL.jpg" alt="" width="200" height="186" /></a></p>
<p>The post <a href="https://rapid-tech.com.au/yokogawa-ca71-handy-multifunction-calibrator/">Yokogawa CA71 Handy Multifunction Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4><strong>Yokogawa CA71 Handy Multifunction Calibrator Features:</strong></h4>
<p>Source and measure operations can be performed at the same time.<br />
(Select from the following source signal and measurement signal options: voltage,current, resistance, thermocouple (TC), resistance temperature detector (RTD),frequency, pulse)</p>
<ul>
<li>AC voltages, including supply voltage, can be measured</li>
<li>Includes a wide array of additional functions</li>
<li>Divided output (n/m) function, Auto-step function, Sweep function, Memory function &amp; Communication function are available</li>
<li>20 mA SINK Function</li>
<li>4−20 mA Step Function</li>
<li>Equivalent Output of TC/RTD and Built-in Reference Junction Compensation Sensor(</li>
<li>20 mA SINK Function</li>
<li>4−20 mA Step Function</li>
<li>Generation &amp; Measurement of Pulse Generation and Measurement of Voltage Pulse and Contact Pulse</li>
<li>Pulse Cycle Function</li>
<li>CPM (count/min), CPH (count/hour) Function</li>
<li>Divided Output (n/m) Function</li>
<li>Sweep Function</li>
<li>Memory Function can handle a maximum of 50 sets of data by means of its built-in memory</li>
</ul>
<h4><strong>Yokogawa CA71 Handy Multifunction Calibrator Specifications:</strong></h4>
<table id="Measurement_specs" style="height: 987px;" width="690">
<tbody>
<tr>
<td colspan="4"></td>
</tr>
<tr>
<td><strong>DC Voltage</strong></td>
<td><strong>Range</strong></td>
<td><strong>Accuracy</strong></td>
<td><strong>Resolution</strong></td>
</tr>
<tr>
<td>100 mV</td>
<td>0 to ±110.00 mV</td>
<td>± (0.025% + 20 µV)</td>
<td>10 μV</td>
</tr>
<tr>
<td>1V</td>
<td>0 to ±1.1000 V</td>
<td>± (0.025% + 0.2 mV)</td>
<td>0.1 mV</td>
</tr>
<tr>
<td>10V</td>
<td>0 to ±11.000 V</td>
<td>± (0.025% + 2 mV)</td>
<td>1 mV</td>
</tr>
<tr>
<td>100V</td>
<td>0 to ±110.00 V</td>
<td>± (0.025% + 20 mV)</td>
<td>1 mV</td>
</tr>
<tr>
<td>RTD Output</td>
<td>Source Range</td>
<td>Accuracy</td>
<td>Resolution</td>
</tr>
<tr>
<td>PT 100</td>
<td>-200.0 to 850.0°C</td>
<td>(0.05%+0.6°C)</td>
<td>0.1°C</td>
</tr>
<tr>
<td>JPT 100</td>
<td>-200.0 to 500.0°C</td>
<td>(0.05%+0.6°C)</td>
<td>0.1°C</td>
</tr>
<tr>
<td>Thermocouples</td>
<td>Source Range</td>
<td>Accuracy</td>
<td>Resolution</td>
</tr>
<tr>
<td>K</td>
<td>-200.0 to 1372.0 °C</td>
<td rowspan="7">± (0.05% + 1.5 °C)<br />
(-100 °C or greater)± (0.05% + 2 °C)(-100 °C or less)</td>
<td rowspan="7">1°C</td>
</tr>
<tr>
<td>E</td>
<td>-200.0 to 1000.0°C</td>
</tr>
<tr>
<td>J</td>
<td>-200.0 to 1200.0°C</td>
</tr>
<tr>
<td>T</td>
<td>-200.0 to 400.0°C</td>
</tr>
<tr>
<td>N</td>
<td>-200.0 to 1300.0°C</td>
</tr>
<tr>
<td>L</td>
<td>-200.0 to 900.0°C</td>
</tr>
<tr>
<td>U</td>
<td>-200.0 to 400.0°C</td>
</tr>
<tr>
<td>R</td>
<td>0 to 1768°C</td>
<td rowspan="3">± (0.05% + 2 °C)</p>
<p>(100 °C or greater)</p>
<p>± (0.05% + 3 °C)</p>
<p>(100 °C or less)</td>
<td rowspan="3">1 °C</td>
</tr>
<tr>
<td>S</td>
<td>0 to 1768°C</td>
</tr>
<tr>
<td>B</td>
<td>600 to 1800°C</td>
</tr>
<tr>
<td>DC Current</td>
<td>Range</td>
<td>Accuracy</td>
<td>Resolution</td>
</tr>
<tr>
<td>20 mA</td>
<td>0 to20.000mA</td>
<td>± (0.025% + 4 μA)</td>
<td>1 μA</td>
</tr>
<tr>
<td>100mA</td>
<td>0 to100.00mA</td>
<td>± (0.04% + 30 μA)</td>
<td>10 μA</td>
</tr>
<tr>
<td>Resistance</td>
<td>Range</td>
<td>Accuracy</td>
<td>Resolution</td>
</tr>
<tr>
<td>400 Ω</td>
<td>0 to 400.00 Ω</td>
<td>± (0.05% + 0.1 Ω)</td>
<td>0.01 Ω</td>
</tr>
<tr>
<td>AC Voltage</td>
<td>Source Range</td>
<td>Accuracy</td>
<td>Resolution</td>
</tr>
<tr>
<td>1 V</td>
<td>0 to 1.100 V</td>
<td rowspan="3">± (0.5% + 5 dgt)</td>
<td>1 mV</td>
</tr>
<tr>
<td>10 V</td>
<td>0 to 11.00 V</td>
<td>0.01V</td>
</tr>
<tr>
<td>100 V</td>
<td>0 to 110.0 V</td>
<td>0.1 V</td>
</tr>
<tr>
<td>300 V</td>
<td>0 to 3000 V</td>
<td>± (0.5% + 2 dgt)</td>
<td>1 V</td>
</tr>
<tr>
<td>AC Voltage</td>
<td>Source Range</td>
<td>Accuracy</td>
<td>Resolution</td>
</tr>
<tr>
<td>100 Hz</td>
<td>1.00 to 100.00 Hz</td>
<td rowspan="5">± 2 dgt</td>
<td>0.01 Hz</td>
</tr>
<tr>
<td>1000 Hz</td>
<td>1.0 to 1000.0 Hz</td>
<td>0.1 Hz</td>
</tr>
<tr>
<td>10 kHz</td>
<td>0.001 to 11.000 kHz</td>
<td>0.001 kHz</td>
</tr>
<tr>
<td>CPM</td>
<td>1 to 99999 CPM</td>
<td>1 CPM</td>
</tr>
<tr>
<td>CPH</td>
<td>1 to 99999 CPH</td>
<td>1 CPH</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table id="Specifications">
<colgroup>
<col />
<col /></colgroup>
<tbody>
<tr>
<td colspan="2"><strong>Model: Yokogawa CA71 Calibrator</strong></td>
</tr>
<tr>
<td colspan="2">Source Unit</td>
</tr>
<tr>
<td>Voltage limiter:</td>
<td>Approx. 32 V</td>
</tr>
<tr>
<td>Current limiter:</td>
<td>Approx. 25 mA</td>
</tr>
<tr>
<td colspan="2"><strong>Measurement Unit</strong></td>
</tr>
<tr>
<td>Voltage terminal:</td>
<td>42 VDC</td>
</tr>
<tr>
<td>Current terminal:</td>
<td>120 mA</td>
</tr>
<tr>
<td>Loop Power :</td>
<td>Single 24 VDC power supply, Fuse: 125 mA/250 V</td>
</tr>
<tr>
<td colspan="2"><strong>General Specifications</strong></td>
</tr>
<tr>
<td>Battery:</td>
<td>Four AA-size (LR6) alkaline batteries, or special AC adapter</td>
</tr>
<tr>
<td>Battery life:</td>
<td>Measurement off, output 5 V DC/10 kΩ or greater: Approximately 40 hours</p>
<p>Simultaneous signal generation/measurement, output 5 V DC/10 kΩ or greater:</p>
<p>Approximately 20 hours</p>
<p>Simultaneous signal generation/measurement, output 20 mA/5 V: Approximately 12 hours</p>
<p>(using alkaline batteries, with backlight off)</td>
</tr>
<tr>
<td>Auto-step output function:</td>
<td>n value sent automatically when n/m function is selected (two options: approximately 2.5 seconds/step or approximately 5 seconds/step)</td>
</tr>
<tr>
<td>Insulation resistance:</td>
<td>Across input terminal and output terminal, 500V DC, 50 MΩ or greater</td>
</tr>
<tr>
<td>Withstand voltage:</td>
<td>Across input terminal and output terminal, 3.7 kV AC, for one minute</td>
</tr>
<tr>
<td>Dimensions:</td>
<td>Approximately 190 × 120 × 55 mm</td>
</tr>
<tr>
<td>Weight:</td>
<td>Approximately 730 g (including batteries)</td>
</tr>
<tr>
<td>Operating temperature:</td>
<td>0 to 50°C, 20 to 80%RH (no condensation)</td>
</tr>
<tr>
<td>Storage temperature:</td>
<td>–20 to 50°C 90%RH or less (no condensation)</td>
</tr>
<tr>
<td>Communication:</td>
<td>Serial interface: RS232 D-Sub 9-pin connector</td>
</tr>
<tr>
<td>Safety:</td>
<td>IEC61010-1, EN61010-2-031</td>
</tr>
<tr>
<td>EMC:</td>
<td>EN61236-1 Class B, EN61000-3-2, EN61000-3-3</p>
<p>EN55011: Group1, Class</p>
<p>EN61326 Annex B</td>