<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Calibrators Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/calibrators-meatest/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/calibrators-meatest/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Wed, 13 May 2026 05:14:08 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.7</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>Calibrators Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/calibrators-meatest/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Meatest 9020 Multifunction Calibrator &#124; 9 ppm Lab Reference</title>
		<link>https://rapid-tech.com.au/meatest-9020-multifunction-calibrator-9-ppm-lab-reference/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Wed, 13 May 2026 02:07:40 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=1119235</guid>

					<description><![CDATA[<p><img class="alignnone wp-image-27271 " src="https://rapid-tech.com.au/wp-content/uploads/2023/12/Meatest-logo-300x109.png" alt="Meatest logo" width="248" height="90" /></p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Running a calibration lab means your reference standard has to be better than everything it tests — by a significant margin.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The Meatest 9020 is a bench-top multifunction calibrator that sources AC/DC voltage to 1050 V, current to 30 A, resistance, capacitance, power, temperature, and frequency from a single instrument, with a basic uncertainty of just 9 ppm.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Whether you're certifying 6½-digit DMMs, clamp meters, power analysers, insulation testers, or oscilloscopes, the 9020 handles your entire calibration workload — compliantly, traceably, and without compromise.</p>
<p><img class="alignnone size-full wp-image-19718" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" /> <a target="_blank" href="https://www.meatest.com/pages/File.aspx?id=3c317f12-a45a-4ee2-9a00-e10f1cfb31be" rel="noopener">Datasheets</a></p>
<p><img class="alignnone size-full wp-image-19718" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" /> <a target="_blank" href="https://www.meatest.com/pages/File.aspx?id=3e1cead1-d49d-40e8-8c7f-a8d2a0d5444f" rel="noopener">Manuals</a></p>
<p>The post <a href="https://rapid-tech.com.au/meatest-9020-multifunction-calibrator-9-ppm-lab-reference/">Meatest 9020 Multifunction Calibrator | 9 ppm Lab Reference</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">The Bottleneck Every Calibration Lab Knows</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">If your lab handles a mix of multimeters, clamp meters, power meters, and insulation testers, you&#8217;ve probably lived with the compromise: multiple reference sources, multiple setups, multiple opportunities for error.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Swapping between instruments mid-calibration wastes time, introduces connection uncertainty, and makes automated workflows unnecessarily complex. Add oscilloscope calibration to the mix and you&#8217;re looking at a second (or third) piece of kit occupying valuable bench space.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The Meatest 9020 Multifunction Calibrator is designed to eliminate that bottleneck. It consolidates the output functions your lab needs most — AC/DC voltage and current, resistance, capacitance, power, energy, temperature simulation, and frequency — into a single, rack-mountable reference instrument with a 9 ppm basic uncertainty.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">For labs servicing everything from handheld DMMs to 6½-digit bench meters, it covers the full workload without the clutter.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">One Instrument. Your Entire Electrical Calibration Workload.</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The 9020 is built around a broad-coverage output architecture designed for the realities of a mixed-instrument calibration lab. Here&#8217;s what it sources:</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>AC/DC Voltage (0 mV – 1050 V)</strong> Covers both DC and AC sine from 1 mVRMS to 1050 VRMS, with non-sine waveforms (sawtooth, triangle, square, truncated sine) available up to 200 VRMS. DC basic uncertainty is as low as 8 ppm of value on the 20 V range — suitable as a reference for all but the most demanding 8½-digit DMM calibrations. AC uncertainty runs to 160 ppm across the primary range. Frequency accuracy is 5 ppm with 5-digit resolution across the 3 Hz – 300 kHz span.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>AC/DC Current (0 µA – 30 A)</strong> The 9020 pushes current output to 30 A — making it well suited for calibrating high-range clamp meters used by industrial maintenance teams and energy monitoring specialists. With the optional 0950 Current Coil accessory, simulated current scales to 1500 A with a 45–65 Hz frequency range and 0.3 % additional uncertainty. DC current uncertainty is as low as 100 ppm on the mid-ranges, with AC uncertainty from 300 ppm at standard frequencies.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Resistance &amp; Capacitance</strong> Variable resistance simulation from 0 Ω to 1.1 GΩ with 6½-digit resolution and uncertainty as tight as 15 ppm (1 kΩ–100 kΩ fixed standards). Capacitance sources from 600 pF to 120 mF with 0.15% uncertainty across the primary range. Both 4-wire (Kelvin) and 2-wire modes are supported, with dedicated 2W-COMP mode for compensated 2-wire measurements.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>AC/DC Power &amp; Energy (40 µW – 31.5 kW)</strong> Power calibration spans DC to 1000 Hz across voltage and current combinations from 0.2 V/0.2 mA up to 1050 V/30 A. Phase shift uncertainty is 0.15° to 200 Hz. Total power accuracy on a 230 V/50 Hz EU grid with a 1 A load is 0.069 % of value — highly competitive for calibrating energy meters and power analysers used in sub-metering, solar PV monitoring, and industrial energy management. Harmonic distortion capability covers 50 harmonic products (15–1000 Hz fundamental), making the 9020 directly applicable to testing power quality instruments against harmonic content requirements.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Temperature Simulation (RTD &amp; Thermocouple)</strong> RTD simulation supports Pt385, Pt3916, Pt3926, Ni672, Cu427, Cu428, and custom curves with R0 range 20 Ω–2 kΩ. Uncertainty is 0.01–0.07 °C. Thermocouple support covers types A, B, C, D, E, G, J, K, L, M, N, R, S, T, U, and XK, with manual or automatic cold junction compensation via Adapter 91. TC uncertainty ranges 0.05–0.55 °C — adequate for calibrating all common industrial temperature instruments.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Frequency (0.1 Hz – 2 MHz)</strong> Square-wave frequency output at 100 mVpk, 1 Vpk, or 3 Vpk with 5 ppm accuracy and duty cycle control (0.1%–99.9%). Suitable for calibrating frequency-input process meters, panel instruments, and data loggers.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Built-In Process Multimeter</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">An optional internal measurement module (MER option) allows the 9020 to simultaneously source a stimulus signal and measure the device under test&#8217;s output — critical for calibrating transducers, loop-powered process transmitters, and industrial sensors. The built-in meter covers DC voltage (0–12 V), DC current (0–24 mA), resistance (0–20 kΩ), RTD and thermocouple temperature, and frequency (1 Hz–100 kHz).</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">This simultaneous source-and-measure capability simplifies transducer calibration workflows considerably and supports simulation of strain gauges and other bridge-type sensors via the 9000-60 cable accessory.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Oscilloscope Calibration Options</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Two scope calibration options extend the 9020&#8217;s frequency output into the RF domain:</p>
<ul class="[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3">
<li class="font-claude-response-body whitespace-normal break-words pl-2"><strong>SCO option</strong>: Levelled sine output to 400 MHz, pulse/time marker to 400 MHz, trigger output, and input impedance measurement (100 Ω / 2 MΩ). Amplitude uncertainty 0.5% + 350 µVpk at low frequency, extending to 3.7% at 400 MHz. Jitter &lt; 2 ns, rise time &lt; 1 ns.</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2"><strong>SC1 option</strong>: Extends levelled sine to 1.1 GHz (amplitude range 1.4 mVpk–1.5 Vpk to 1 GHz; 1.4 mVpk–1 Vpk above 1 GHz). Frequency uncertainty drops to 0.1 ppm in pulse/time marker mode.</li>
</ul>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">These options make the 9020 one of the few compact multifunction calibrators capable of supporting both bench instrument calibration and oscilloscope bandwidth verification from a single chassis.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">High Voltage Resistance for Insulation Tester Calibration</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The HVR option adds a dedicated high-voltage resistance output specifically designed for verifying insulation resistance testers and megaohmmeters. Resistance range spans 100 kΩ to 100 GΩ with test voltages to 1500 VDC. This is directly relevant to Australian labs calibrating instruments used under AS/NZS 3000 compliance programs, electrical safety testing, and NATA-accredited electrical calibration services. Resistance uncertainty is 0.2–3% depending on range; test voltage uncertainty 0.3%–1.5% + 5 V.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Automation and Lab Integration</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The 9020 ships with RS-232, IEEE-488 (GPIB), USB, and Ethernet interfaces as standard — making it straightforward to integrate with existing automated calibration platforms. For labs using Meatest&#8217;s own WinQbase or Caliber software, the 9020 supports the CamOCR optical readout module, which allows semi-automated calibration of instruments with no remote control interface — useful for legacy analogue meters and older DMMs. A full communication API is documented in the user manual for custom automation development.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Preset storage allows senior technicians to define verified output configurations that less experienced operators can recall and execute, reducing human error in high-throughput calibration environments.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Why It Suits Australian Calibration Labs</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Australian labs operating under NATA accreditation requirements need calibration sources with traceable uncertainty chains that clearly support the instruments under test. The 9020&#8217;s 12-month stability specifications — stated at 95% confidence, k=2 — satisfy the rigorous uncertainty budgeting requirements of ISO/IEC 17025.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Its coverage of insulation resistance (to 1.5 kV), power (AC/DC to 1050 V/30 A), and temperature simulation means a single instrument can support calibration of the test equipment categories most commonly used by Australian electrical contractors, industrial maintenance teams, and compliance testers working to AS/NZS 3000, AS/NZS 3017, and related standards.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">For calibration businesses and in-house labs looking to reduce instrument capital while maintaining accreditation-ready uncertainty performance, the 9020 represents a compelling consolidation investment.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h2 class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold">USE CASES</h2>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">1. NATA-Accredited Electrical Calibration Laboratories</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The 9020&#8217;s 9 ppm DC voltage accuracy and comprehensive multi-function output make it a primary reference source for calibrating multimeters, clamp meters, and bench DMMs across the full workload of a general electrical calibration lab.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Its IEC 61010 safety compliance and traceable uncertainty specifications align directly with ISO/IEC 17025 accreditation requirements.</p>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">2. Power Analyser and Energy Meter Calibration</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">With AC/DC power output to 31.5 kW (1575 kW with optional 0950 Current Coil), phase shift uncertainty of 0.15° to 200 Hz, and 50-harmonic generation capability, the 9020 is well-suited to calibrating single and three-phase power analysers, revenue-grade energy meters, and power quality instruments used in industrial sub-metering and solar PV grid connection applications.</p>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">3. Industrial Transducer and Process Meter Calibration</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The optional MER module enables simultaneous sourcing and measurement, supporting the calibration of loop-powered 4–20 mA transmitters, pressure and temperature transducers, and process meters. Combined with RTD and thermocouple simulation, this makes the 9020 valuable for industrial maintenance calibration teams in manufacturing, resources, and utilities sectors.</p>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">4. Oscilloscope Bandwidth Verification</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">With the SCO (400 MHz) or SC1 (1.1 GHz) option, the 9020 extends into oscilloscope calibration territory — delivering levelled sine signals, pulse/time markers, trigger outputs, and input impedance measurement from the same chassis that handles DC voltage reference work.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">This suits calibration service providers who need oscilloscope capability without a dedicated RF calibrator.</p>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">5. Insulation Tester and Megohmeter Calibration</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The HVR option provides test voltages to 1500 VDC with resistance simulation from 100 kΩ to 100 GΩ — directly addressing the calibration requirements for insulation resistance testers (Meggers) used across Australia&#8217;s electrical contracting, industrial, and infrastructure sectors, where compliance with AS/NZS 3000 and AS/NZS 3760 is mandatory.</p>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">6. Electrical Safety Test Equipment Calibration Services</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Calibration service providers offering certificate-of-calibration services to electrical contractors, facilities managers, and industrial clients can use the 9020 to support PAT tester, loop tester, and installation tester calibration programmes. The instrument&#8217;s broad output coverage reduces the number of reference sources required and simplifies multi-function service delivery.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h2 class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold">TECHNICAL SPECIFICATIONS</h2>
<div class="overflow-x-auto w-full px-2 mb-6">
<table class="min-w-full border-collapse text-sm leading-[1.7] whitespace-normal">
<thead class="text-left">
<tr>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">Parameter</th>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">Specification</th>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">Why It Matters</th>
</tr>
</thead>
<tbody>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Basic DC Voltage Uncertainty</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">8–30 ppm (range dependent, 1-year, k=2)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Sets the minimum uncertainty budget for all DMM and voltmeter calibrations</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>DC Voltage Range</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">0 mV – 1050 V</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Covers full low-voltage span from signal-level to mains-equivalent</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>AC Voltage Range</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">1 mVRMS – 1050 VRMS, 3 Hz – 300 kHz</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Covers audio-frequency through RF-adjacent calibration requirements</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>DC Current Range</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">0 µA – 30 A</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Calibrates clamp meters and high-range ammeters directly</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>AC Current Range</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">10 µARMS – 30 ARMS, 10 Hz – 30 kHz</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Enables full AC clamp meter and current transducer calibration</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Current Output (with 0950 Coil)</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Up to 1500 A simulated</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Required for large clamp meter calibration (e.g. 1000 A range)</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Resistance Range</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">0 Ω – 1.1 GΩ (variable); 0 Ω – 1 GΩ (fixed standards)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Full coverage for DMM, LCR meter, and ohmmeter calibration</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Resistance Uncertainty (15 ppm)</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">1 kΩ – 100 kΩ fixed standards</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Supports 6½-digit DMM calibration at reference-grade accuracy</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Capacitance Range</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">600 pF – 120 mF</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Calibrates capacitance meters and LCR instruments across practical ranges</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Capacitance Uncertainty</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">0.12–0.45% (range dependent)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Sufficient for all commercial and trade-grade capacitance meter calibration</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Power Range</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">40 µW – 31.5 kW (DC + AC 15–1000 Hz)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Covers sub-watt signal-level through high-power three-phase meter calibration</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Power Accuracy (230 V/50 Hz, 1 A)</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">0.069% of value</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Meets revenue meter calibration requirements in Australian energy sector</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Harmonic Distortion Output</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">50 products, 15–1000 Hz fundamental</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Validates power quality analyser harmonic measurement performance</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Phase Shift Uncertainty</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">0.15° (≤200 Hz), 0.25° (&gt;200 Hz)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Directly affects power factor and reactive power calibration accuracy</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Temperature (RTD)</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Pt385, Pt3916, Pt3926, Ni672, Cu427, Cu428, custom</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Covers all common industrial RTD standards</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>RTD Uncertainty</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">0.01–0.07 °C</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Laboratory-grade temperature simulation for calibrating RTD transmitters</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Temperature (TC)</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Types A, B, C, D, E, G, J, K, L, M, N, R, S, T, U, XK</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Broadest thermocouple type coverage available in this class</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>TC Uncertainty</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">0.05–0.55 °C</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Adequate for all common industrial TC instrument calibration</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Frequency Range</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">0.1 Hz – 2 MHz</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Calibrates frequency-input panel meters, counters, and data loggers</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Frequency Accuracy</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">5 ppm</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Excellent for general-purpose frequency meter calibration</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Scope Option (SCO)</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Levelled sine to 400 MHz</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Oscilloscope bandwidth calibration without a dedicated RF calibrator</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Scope Option (SC1)</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Levelled sine to 1.1 GHz</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">High-bandwidth oscilloscope calibration for service and metrology labs</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Insulation Resistance (HVR Option)</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">100 kΩ – 100 GΩ, up to 1500 VDC</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Calibrates insulation testers and megaohmmeters used in electrical compliance</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Interfaces</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">RS-232, IEEE-488 (GPIB), USB, Ethernet</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Full automation compatibility; no additional interface cards required</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Safety Compliance</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">IEC 61010 ed. 2 (Safety Class I), EN 61326 (ESD Class I), Overvoltage CAT II</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Meets laboratory safety requirements</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Operating Temperature</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">+13 °C – +33 °C</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Standard lab environment; reference temperature 21–25 °C</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Warm-Up Time</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">30 minutes</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Standard for instruments of this class; plan calibration schedules accordingly</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Power Supply</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">115/230 V, 50/60 Hz, 450 VA max</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Compatible with Australian 230 V/50 Hz mains supply</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Dimensions (W × H × D)</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">434 × 191 × 641 mm</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Standard 3U/4U rack-mountable bench footprint</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Weight</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">24–25 kg (options dependent)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Bench-use instrument; not designed for field transport</td>
</tr>
</tbody>
</table>
</div>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h2 class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold">AVAILABLE OPTIONS</h2>
<div class="overflow-x-auto w-full px-2 mb-6">
<table class="min-w-full border-collapse text-sm leading-[1.7] whitespace-normal">
<thead class="text-left">
<tr>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">Option Code</th>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">Description</th>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">Best For</th>
</tr>
</thead>
<tbody>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>SCO</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Oscilloscope calibration to 400 MHz; includes N/BNC adapter</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Labs calibrating general-purpose oscilloscopes</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>SC1</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Oscilloscope calibration to 1.1 GHz; includes N/BNC adapter</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Service labs with high-bandwidth scope calibration requirements</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>HVR</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">High voltage resistance to 1.5 kV; includes 191-11 5 kV cable</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Labs calibrating insulation testers and megaohmmeters</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>MER</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Process multimeter option; includes 9000-60 4W measurement cable</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Transducer and process meter calibration, strain gauge simulation</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>0950 Current Coil</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Multiplication factors 10×, 25×, 50×; max 1500 A</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Large clamp meter and high-current instrument calibration</td>
</tr>
</tbody>
</table>
</div>
<blockquote>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>What is the Meatest 9020 used for?</strong> The Meatest 9020 is a bench-top multifunction calibrator used in electrical calibration laboratories to verify and calibrate a wide range of electrical test instruments. It sources AC and DC voltage (up to 1050 V), AC and DC current (up to 30 A), resistance, capacitance, power, energy, temperature (RTD and thermocouple), and frequency from a single instrument. Optional modules extend its capability to oscilloscope calibration (to 1.1 GHz) and insulation resistance tester calibration (to 1500 VDC). It is designed for labs calibrating multimeters, clamp meters, power analysers, energy meters, process meters, and transducers.</p>
</blockquote>
<blockquote>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>What is the accuracy of the Meatest 9020?</strong> The Meatest 9020 has a basic DC voltage uncertainty of 9 ppm (with the best range achieving 8 ppm of value over 12 months at k=2, 95% confidence). AC voltage uncertainty is from 160 ppm, DC current from 100 ppm, and AC power accuracy at 230 V/50 Hz is approximately 0.069–0.142% depending on current level. All specifications are all-inclusive: they cover 12-month stability, temperature effects, linearity, load regulation, and calibration traceability.</p>
</blockquote>
<blockquote>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Can the Meatest 9020 calibrate insulation testers?</strong> Yes. With the HVR (High Voltage Resistance) option, the Meatest 9020 can calibrate insulation resistance testers and megaohmmeters. The HVR option provides resistance simulation from 100 kΩ to 100 GΩ at test voltages up to 1500 VDC, covering the full measurement range of insulation testers used in electrical safety compliance testing. A 5 kV-rated test cable (191-11) is included with the HVR option.</p>
</blockquote>
<p>The post <a href="https://rapid-tech.com.au/meatest-9020-multifunction-calibrator-9-ppm-lab-reference/">Meatest 9020 Multifunction Calibrator | 9 ppm Lab Reference</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Meatest 9000 &#8211; Advanced Portable Multifunction Calibrator for 3.5 and 4.5 Digit Multimeters – Lightweight and Compact with Enhanced Features</title>
		<link>https://rapid-tech.com.au/meatest-9000-advanced-portable-multifunction-calibrator-for-3-5-and-4-5-digit-multimeters-lightweight-and-compact-with-enhanced-features/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Mon, 18 Dec 2023 22:49:40 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=27269</guid>

					<description><![CDATA[<p><img class="alignnone wp-image-27271 " src="https://rapid-tech.com.au/wp-content/uploads/2023/12/Meatest-logo-300x109.png" alt="Meatest logo" width="248" height="90" /></p>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Discover the <b><strong class="font-bold">Meatest 9000 Portable Multifunction Calibrator</strong></b>, a game-changer in the world of calibrations.</p>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">This compact device, specifically designed for calibrating 3.5 and 4.5 digit multimeters, offers a basic accuracy of 60 ppm and includes a smart terminal layout for cable-free operations. It's lightweight, portable and perfect for onsite calibrations. Enhanced features like wider frequency ranges, new capacitance function, and stronger outputs set it apart.</p>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Compatible with CALIBER/WinQBase, the 9000 enables efficient remote control and automation in labs and on industrial test rigs.</p>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Upgrade your calibration process with the <b><strong class="font-bold">Meatest 9000</strong></b>. Order now, and experience the difference!</p>
<p><img class="alignnone size-full wp-image-19718" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" />  <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2023/12/9000d.pdf" rel="noopener">Meatest 9000 Datasheet</a><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2022/08/MEATEST-9010-Multifunction-Calibrator-User-Manual-.pdf" rel="noopener"></a></p>
<p>The post <a href="https://rapid-tech.com.au/meatest-9000-advanced-portable-multifunction-calibrator-for-3-5-and-4-5-digit-multimeters-lightweight-and-compact-with-enhanced-features/">Meatest 9000 &#8211; Advanced Portable Multifunction Calibrator for 3.5 and 4.5 Digit Multimeters – Lightweight and Compact with Enhanced Features</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 class="font-bold text-gray-800 text-h3 leading-[36px] pt-[21px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]" dir="ltr">Experience the Meatest 9000 Portable Multifunction Calibrator &#8211; Your Perfect Calibration Solution</h2>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Immerse yourself in the ultimate calibration experience with the <b><strong class="font-bold">Meatest 9000 Portable Multifunction Calibrator</strong></b>. This all-in-one device, perfectly designed for calibrating 3.5 and 4.5 digit multimeters, boasts a basic accuracy of 60 ppm and eliminates the need for tedious cable switching with its smart terminal layout.</p>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Engineered with features that exceed its predecessor, the M143, the 9000 offers a wider range of frequencies, a new capacitance function, and stronger outputs. It&#8217;s designed to handle the modern day workload, including LoZ function calibration, process meters, and even panel meters.</p>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Despite its high functionality, the <b><strong class="font-bold">Meatest 9000</strong></b> maintains a compact and lightweight design. Its briefcase size and 11 kg weight make it an ideal companion for onsite calibrations. The friendly interface, marked by a generous 8” touchscreen display, ensures easy operation even with inaccurate inputs.</p>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">What&#8217;s more? With USB, Ethernet, and IEEE488 interfaces, the 9000 promotes remote control and automation in calibration labs as well as on industrial test rigs. It&#8217;s fully compatible with the Meatest calibration software package CALIBER/WinQBase, which includes the CamOCR Camera Readout Module, making handheld multimeter calibration a breeze.</p>
<p class="text-body font-regular text-gray-800 leading-[24px] pt-[9px] pb-[2px]" dir="ltr">Upgrade your calibration process with the <b><strong class="font-bold">Meatest 9000 Portable Multifunction Calibrator</strong></b>. It&#8217;s more than a device; it&#8217;s a game-changer in the world of calibrations. Order now and experience the difference!</p>
<h4 class="font-bold text-gray-800 text-body leading-[24px] pt-[12px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]" dir="ltr">HIGHLIGHTS</h4>
<ul class="pt-[9px] pb-[2px] pl-[24px] list-disc [&amp;_ul]:pt-[5px] pt-[5px]">
<li class="text-body font-regular text-gray-800 leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="1">All-round calibrator for 3.5 and 4.5 digit multimeters</li>
<li class="text-body font-regular text-gray-800 leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="2">1050 V, 20.5 A, resistance, capacitance, TC, RTD and frequency</li>
<li class="text-body font-regular text-gray-800 leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="3">Basic accuracy 60 ppm</li>
<li class="text-body font-regular text-gray-800 leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="4">Terminal layout eliminates need for cable switching</li>
<li class="text-body font-regular text-gray-800 leading-[24px] my-[5px] [&amp;&gt;ol]:!pt-0 [&amp;&gt;ol]:!pb-0 [&amp;&gt;ul]:!pt-0 [&amp;&gt;ul]:!pb-0" value="5">Compact, light, ideal for onsite calibrations</li>
</ul>
<p>The post <a href="https://rapid-tech.com.au/meatest-9000-advanced-portable-multifunction-calibrator-for-3-5-and-4-5-digit-multimeters-lightweight-and-compact-with-enhanced-features/">Meatest 9000 &#8211; Advanced Portable Multifunction Calibrator for 3.5 and 4.5 Digit Multimeters – Lightweight and Compact with Enhanced Features</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MEATEST 9010+ Multifunction Calibrator</title>
		<link>https://rapid-tech.com.au/meatest-9010-plus-multifunction-calibrator/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Thu, 18 Aug 2022 04:41:10 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=22675</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-28" src="https://rapid-tech.com.au/wp-content/uploads/2015/12/MEATEST_logo_PL.jpg" alt="" width="125" height="28" /></p>
<p>MEATEST 9010+ Multifunction Calibrator can be used to calibrate multimeters, power meters, and a variety of other electric meters. With its modular design, the 9010+ can also be customized to calibrate oscilloscopes, insulation testers, sources, and transducers. So whether you need a basic calibration or something more specific, this calibrator has you covered. And with a 10 ppm AC/DC rating, you can be confident in the results. So make your life easier with the 9010+ multifunction calibrator.</p>
<p>Features</p>
<ul>
<li>10 ppm accuracy</li>
<li>400 MHz and 1.1 GHz scope options</li>
<li>Power quality functions, voltage from current</li>
</ul>
<p><img class="alignnone size-full wp-image-19718" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" />  <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2022/08/MEATEST-9010-Multifunction-Calibrator-Datasheet.pdf" rel="noopener">MEATEST 9010+ Multifunction Calibrator Datasheet</a></p>
<p><img class="alignnone size-full wp-image-19718" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" />  <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2022/08/MEATEST-9010-Multifunction-Calibrator-User-Manual-.pdf" rel="noopener">MEATEST 9010+ Multifunction Calibrator User Manual</a></p>
<p>The post <a href="https://rapid-tech.com.au/meatest-9010-plus-multifunction-calibrator/">MEATEST 9010+ Multifunction Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="justify"><div class="epyt-video-wrapper"><iframe  id="_ytid_37838"  width="1020" height="574"  data-origwidth="1020" data-origheight="574"  data-relstop="1" src="https://www.youtube.com/embed/YxUdeCNytk4?enablejsapi=1&autoplay=0&cc_load_policy=0&cc_lang_pref=&iv_load_policy=1&loop=0&rel=0&fs=1&playsinline=1&autohide=2&theme=dark&color=red&controls=1&disablekb=0&" class="__youtube_prefs__  no-lazyload" title="9010+ Multifunction Calibrator"  allow="fullscreen; accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen data-no-lazy="1" data-skipgform_ajax_framebjll=""></iframe></div>
<p align="justify">&#8211;</p>
<p align="justify">Multifunction calibrator 9010+ is designed as universal calibration tool for electrical calibration laboratories, covering most of their workload like 6½ digit multimeters, clamp meters, ohm meters, power meters and power analysers, energy meters, transducers, insulation testers, process meters, oscilloscopes and many others. High load capacity of voltage output (up to 50 mA) allows for calibration of high-consumption analogue meters. Installed harmonic and non-harmonic shape signals allow for testing meter sensitivity to distorted signals by a signal with various crest factor.<br />
9010+ takes advantage of 9010&#8217;s wide workload coverage and modern user interface ans pushes its performance even further by accuracy improvements in most functions, current range extension to 30 A, power range extension to 1575 kW and ultimately 1.1 GHz o-scope calibration capability with SC1 option (expected in 12/2022).</p>
<h3>Built-in multimeter</h3>
<p align="justify">Internal multimeter with basic capability to measure VDC, IDC, R and F process signals is optionally available in 9010+. Meter functions can run simultaneously with source functions to measure and evaluate output signals of various types of transducers as well as external sensors (strain gauge, pressure, torsion, force, etc.).</p>
<h3>User comfort</h3>
<p align="justify">9010+ calibrator is focused on user friendliness making calibrations simple and straightforward. Each function has its dedicated chunky button and all relevant details like total uncertainty, limits or connection scheme are shown on large LCD. Various output setups can be saved as Presets and recalled from memory when needed. This way a skilled technician can define verified presets for other operators, avoiding human error and streamlining manual calibration.<br />
9010+ can be operated remotely via RS-232, GPIB, USB or Ethernet as part of custom automated solutions (complete communication API is described in user manual) or in WinQbase/Caliber automated calibration systems featuring automated optical UUT readouts.</p>
<h3>Upgrade options</h3>
<p align="justify">Customers using 9010 Multifunction Calibrators with serial numbers 750381 and higher can request upgrade to 9010+ Multifunction Calibrator. Upgrades will be done in Meatest CZ with 6 week average lead time, starting in November 2022.<br />
9010+ internal options SCO, HVR, MER can be retrofitted at any time. SC1 retrofits will be available from 2023. Ask your local Meatest representative for lead times and pricing.</p>
<p>The post <a href="https://rapid-tech.com.au/meatest-9010-plus-multifunction-calibrator/">MEATEST 9010+ Multifunction Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MEATEST 9010 Multifunction Calibrator</title>
		<link>https://rapid-tech.com.au/meatest-9010-multifunction-calibrator/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Thu, 06 Dec 2018 10:11:09 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=9416</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-28" src="https://rapid-tech.com.au/wp-content/uploads/2015/12/MEATEST_logo_PL.jpg" alt="" width="125" height="28" /></p>
<p>The new MEATEST 9010 is a 35 ppm AC/DC multifunction calibrator for multimeters, power meters and generally all kinds of electric meters. Implementing modular design, 9010 can be further customized to calibrate oscilloscopes, insulation testers, sources and transducers.</p>
<p><strong>Features</strong></p>
<div class="product__description highlights texts-default">
<ul>
<li>35 ppm accuracy</li>
<li>400 MHz scope option</li>
<li>Power quality functions, voltage from current</li>
</ul>
</div>
<h4><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" />    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-9010-Datasheet.pdf" rel="noopener"><span style="font-size: 110%;">Meatest 9010 Datasheet</span></a></span></h4>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-9010-User-Manual.pdf" rel="noopener">Meatest 9010 User Manual</a></span></h4>
<h4><a href="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg"><img class="alignnone size-full wp-image-4322" src="https://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="" width="55" height="56" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-9010-Remote-Control-Manual.pdf" rel="noopener">Meatest 9010 Remote Control Manual</a></span></h4>
<p>The post <a href="https://rapid-tech.com.au/meatest-9010-multifunction-calibrator/">MEATEST 9010 Multifunction Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="epyt-video-wrapper"><iframe  id="_ytid_79075"  width="1020" height="574"  data-origwidth="1020" data-origheight="574"  data-relstop="1" src="https://www.youtube.com/embed/in4Cg_gMYuQ?enablejsapi=1&autoplay=0&cc_load_policy=0&cc_lang_pref=&iv_load_policy=1&loop=0&rel=0&fs=1&playsinline=1&autohide=2&theme=dark&color=red&controls=1&disablekb=0&" class="__youtube_prefs__  no-lazyload" title="9010 Multifunction Calibrator"  allow="fullscreen; accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen data-no-lazy="1" data-skipgform_ajax_framebjll=""></iframe></div>
<p>&#8211;</p>
<p>When the 9100E Multifunction Calibrator ceased production it left a hole in the market for a versatile (50ppm) workhorse calibrator that is able to handle a wide workload of calibration including Insulation Testers, Clamps,  Power Meters &amp; if required, Oscilloscopes. &#8211;  Well now the MEATEST 9010 Multifunction Calibrator with it&#8217;s ± 35 ppm/year DC accuracy is able to fill these calibration needs.</p>
<p align="justify">The MEATEST 9010 Multifunction Calibrator is designed as universal calibration tool for electrical calibration laboratories, covering most of their workload like multimeters, clamp meters, ohm meters, power meters and power analysers, energy meters, transducers, insulation testers, process meters, scopes and many others.</p>
<p align="justify">High load capacity of voltage output (up to 50 mA) allows for calibration of high-consumption analogue meters. Installed harmonic and non-harmonic shape signals allow for testing meter sensitivity to distorted signals by a signal with various crest factor. Advancing from previous M14x calibrator series, 9010 can now calibrate even 400 MHz scopes, 1.5 kV insulation testers and 280 kW power meters.</p>
<p align="justify">It has all the popular functions including complete transducer and external sensor calibration (strain gauge, pressure, torsion, force, etc.) using optional built-in multimeter, automatic uncertainty calculation, remote control and easy recalibration.</p>
<h3 align="justify">MEATEST 9010 Features</h3>
<ul>
<li>AC/DC voltage/current up to <strong>1050V/20A</strong></li>
<li>Basic uncertainty <strong>35 ppm</strong></li>
<li><strong>AC/DC power, energy, resistance, capacitance, frequency, TC, RTD</strong></li>
<li><strong>Scope option</strong> up to 400 MHz</li>
<li>High voltage resistance option for <strong>1.5 kV insulation testers</strong></li>
<li>Built-in process multimeter</li>
<li>Interface <strong>RS232, LAN, USB, GPIB</strong></li>
</ul>
<h3>Built-in multimeter</h3>
<p align="justify">An Internal multimeter with basic capability to measure VDC, IDC, R and F process signals is optionally available in 9010. Meter functions can run simultaneously with source functions to measure and evaluate output signals of various types of transducers as well as external sensors (strain gauge, pressure, torsion, force, etc.).</p>
<h3>User comfort</h3>
<p align="justify">The Meatest 9010 calibrator is focused on user friendliness making calibrations simple and straightforward. Each function has its dedicated chunky button and all relevant details like total uncertainty, limits or connection scheme are shown on large LCD. Relative deviation feature can help you with UUT error calculation and this intuitive user environment will even allow you to adjust all internal functions and ranges with no additional equipment.</p>
<p align="justify">The 9010 can be operated remotely via GPIB or RS-232 and can be used both in custom automated solutions (complete communication API is described in user manual) or in WinQbase/Caliber automated calibration systems featuring automated optical UUT readouts.</p>
<h3 align="justify">MEATEST 9010 Front Panel</h3>
<p align="justify"><a href="https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Front-Pannel.jpg"><img decoding="async" class="alignnone wp-image-16571 size-medium" src="https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Front-Pannel-300x157.jpg" alt="" width="300" height="157" srcset="https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Front-Pannel-300x157.jpg 300w, https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Front-Pannel-600x314.jpg 600w, https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Front-Pannel.jpg 750w" sizes="(max-width: 300px) 100vw, 300px" /></a></p>
<p align="justify">1. Output terminals<br />
2. Display<br />
3. Numeric and navigation keys<br />
4. Function keys<br />
5. Input terminals<br />
6. Softkeys (sky blue) and menu keys (grey)</p>
<h3 align="justify">MEATEST 9010 Multifunction Calibrator Specifications</h3>
<table class="vychoziTabulka">
<tbody>
<tr>
<td>DC voltage</td>
<td>0 &#8211; 1050 V<br />
± 35 ppm / year</td>
</tr>
<tr>
<td>AC voltage</td>
<td>1 mV &#8211; 1050 V, 15 Hz &#8211; 300 kHz<br />
sinusoidal &amp; non-sinusoidal waveforms, harmonics<br />
± 250 ppm / year</td>
</tr>
<tr>
<td>DC current</td>
<td>0 &#8211; 20 A (1000 A with 140-50 Current Coil)<br />
± 150 ppm / year</td>
</tr>
<tr>
<td>AC current</td>
<td>10 uA &#8211; 20 A, 15 Hz &#8211; 10 kHz (1000 A with 140-50 Current Coil)<br />
sinusoidal &amp; non-sinusoidal waveforms, harmonics<br />
± 500 ppm / year</td>
</tr>
<tr>
<td>DC Power &amp; Energy</td>
<td>40 uW &#8211; 5.6 kW (280 kW with 140-50 Current Coil)<br />
± 210 ppm / year</td>
</tr>
<tr>
<td>AC Power &amp; Energy</td>
<td>40 uW &#8211; 5.6 kW, 15 &#8211; 1000 Hz (280 kW with 140-50 Current Coil)<br />
50 harmonic products, voltage from current<br />
± 730 ppm / year</td>
</tr>
<tr>
<td>Resistance</td>
<td>0 Ω &#8211; 1 GΩ, resolution 6½ digits<br />
± 15 ppm / year</td>
</tr>
<tr>
<td>Insulation Resistance</td>
<td>100 kΩ &#8211; 100 GΩ<br />
rated up to 1.5 kV</td>
</tr>
<tr>
<td>Capacitance</td>
<td>800 pF &#8211; 120 mF, resolution 6½ digits<br />
± 0.5 % / year</td>
</tr>
<tr>
<td>Temperature</td>
<td>TC BCDEG<sub>2</sub>JKMNRST with cold junction compensation<br />
RTD ± 0.03°C / year</td>
</tr>
<tr>
<td>Frequency</td>
<td>0.1 Hz &#8211; 400 MHz<br />
± 25 ppm / year</td>
</tr>
</tbody>
</table>
<h3>Process Multimeter</h3>
<table class="vychoziTabulka" style="height: 280px;" width="559">
<tbody>
<tr>
<td>DC voltage</td>
<td>0 &#8211; 12 V<br />
mVDC resolution down to 10 nV<br />
± 50 ppm / year</td>
</tr>
<tr>
<td>DC current</td>
<td>0 &#8211; 24 mA<br />
± 150 ppm / year</td>
</tr>
<tr>
<td>Resistance</td>
<td>0 Ω &#8211; 20 kΩ, resolution 6½ digits<br />
± 200 ppm / year</td>
</tr>
<tr>
<td>Temperature</td>
<td>TC BCDEG<sub>2</sub>JKMNRST<br />
RTD ± 0.08°C / year</td>
</tr>
<tr>
<td>Frequency</td>
<td>1 Hz &#8211; 100 kHz<br />
± 50 ppm / year</td>
</tr>
</tbody>
</table>
<h3>Optional Accessories​</h3>
<table class="vychoziTabulka">
<tbody>
<tr class="accessories__row">
<td class="accessories__cell"><a href="https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Current-Coil-140-50.jpg"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-16567" src="https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Current-Coil-140-50.jpg" alt="" width="400" height="180" srcset="https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Current-Coil-140-50.jpg 400w, https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Current-Coil-140-50-300x135.jpg 300w" sizes="auto, (max-width: 400px) 100vw, 400px" /></a></td>
<td class="accessories__cell accessories__cell--description">
<div class="accessories__cell accessories__cell--title">Current Coil 140-50</div>
<p>multiplication factors x25 and x50, 1500 A maximum</td>
</tr>
<tr class="accessories__row">
<td class="accessories__cell"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-16568" src="https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Adapter-9000-60.jpg" alt="" width="400" height="212" srcset="https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Adapter-9000-60.jpg 400w, https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Adapter-9000-60-300x159.jpg 300w" sizes="auto, (max-width: 400px) 100vw, 400px" /></td>
<td class="accessories__cell accessories__cell--description">
<div class="accessories__cell accessories__cell--title">Adapter 9000-60</div>
<p>for resistance and RTD measurement</td>
</tr>
<tr class="accessories__row">
<td class="accessories__cell"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-16569" src="https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Adapter-91.jpg" alt="" width="400" height="214" srcset="https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Adapter-91.jpg 400w, https://rapid-tech.com.au/wp-content/uploads/2018/12/Meatest-Adapter-91-300x161.jpg 300w" sizes="auto, (max-width: 400px) 100vw, 400px" /></td>
<td class="accessories__cell accessories__cell--description">
<div class="accessories__cell accessories__cell--title">Adapter 91</div>
<p>Pt100 cold junction compensator</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/meatest-9010-multifunction-calibrator/">MEATEST 9010 Multifunction Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Meatest M191 Insulation Tester Calibrator</title>
		<link>https://rapid-tech.com.au/meatest-m191-insulation-tester-calibrator/</link>
					<comments>https://rapid-tech.com.au/meatest-m191-insulation-tester-calibrator/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 28 Mar 2017 02:12:09 +0000</pubDate>
				<guid isPermaLink="false">http://rapid-tech.com.au/?post_type=product&#038;p=4869</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-28" src="http://rapid-tech.com.au/wp-content/uploads/2015/12/MEATEST_logo_PL.jpg" alt="MEATEST_logo_PL" width="125" height="28" /></p>
<div class="productDetailText">
<p>High resistance calibrator for insulation testers up to 10 kV. Other insulation related functions include HV capacitance, short current, dielectric and polarization parameters and timer test.</p>
</div>
<ul>
<li>Six different calibration functions</li>
<li>1 TΩ and 10 kVdc limits</li>
<li>Test voltage and current indication</li>
</ul>
<h4><span style="color: #ff0000;">Authorised Australian Distributor</span></h4>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2017/03/M191-Datasheet.pdf" rel="noopener">M191 Datasheet</a></span></span></h5>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2017/03/M191-Operation-Manual.pdf" rel="noopener">M191 Operation Manual</a></span></span></h5>
<p>The post <a href="https://rapid-tech.com.au/meatest-m191-insulation-tester-calibrator/">Meatest M191 Insulation Tester Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Meatest M191 Insulation Tester Calibrator is designed for the calibration of insulation testers. It can be used for calibration of any DC high resistance meter with working voltage up to 10 kV.</p>
<p>Meatest M191 Insulation Tester Calibrator is based on programmable high resistance decade which is completed with additional electronic circuits allowing calibration not only resistance ranges, but also calibration of test voltage generated by UUT, testing of short current, verifying of functions of measuring dielectric parameters like polarization index (PI), dielectric absorption ratio (DAR) and polarization ratio (PR). The calibrator enables also verification of timer function of UUTs.</p>
<p>Basic feature of the Meatest M191 Insulation Tester Calibrator is adjustable high resistance decades in the range from 10 kΩ to 1 TΩ. The decade is designed for operation voltages up to 10 kV. In this range it offers basic accuracy 0.1% to 5 % depending on set resistance value.</p>
<p>The calibration can be controlled manually using front panel keypad or in remote mode using one of two types of interfaces GPIB, or RS-232.</p>
<p>The Meatest M191 Insulation Tester Calibrator can easily integrate within calibration systems featuring CALIBER software support.</p>
<h4>Meatest M191 Insulation Tester Calibrator Specifications:</h4>
<table class="vychoziTabulka" style="height: 90px;" width="666">
<tbody>
<tr>
<td>DC resistance</td>
<td>10 kΩ &#8211; 1 TΩ, 10.5 kV max.<br />
± 0.1% / year</td>
</tr>
<tr>
<td>DC capacitance</td>
<td>10 nF, 50nF, 100 nF, 5.25 kV max.<br />
± 0.5% / year</td>
</tr>
</tbody>
</table>
<h3>Test Signal Meter</h3>
<table class="vychoziTabulka" style="height: 137px;" width="391">
<tbody>
<tr>
<td>DC voltage</td>
<td>50 V &#8211; 10.5 kV<br />
± 0.5% / year</td>
</tr>
<tr>
<td>DC current</td>
<td>0 &#8211; 5 mA<br />
± 0.2% / year</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/meatest-m191-insulation-tester-calibrator/">Meatest M191 Insulation Tester Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/meatest-m191-insulation-tester-calibrator/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>MEATEST M550 Impedance Calibrator</title>
		<link>https://rapid-tech.com.au/meatest-m550-impedance-calibrator/</link>
					<comments>https://rapid-tech.com.au/meatest-m550-impedance-calibrator/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Mon, 20 Mar 2017 01:42:02 +0000</pubDate>
				<guid isPermaLink="false">http://rapid-tech.com.au/?post_type=product&#038;p=4828</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-28" src="http://rapid-tech.com.au/wp-content/uploads/2015/12/MEATEST_logo_PL.jpg" alt="MEATEST_logo_PL" width="125" height="28" /></p>
<p>The aim of the Meatest M550 Impedance Calibrator is to replace countless single value RCL standards with one calibrator that can switch between the standards like a CD changer in your car.</p>
<p>The MEATEST M550 Impedance Calibrator contains stable and temperature independent resistance standards, partial capacitance standards and partial inductance standards, simulated by RC T-type passive network.</p>
<p>Calibration values of both complex parameters of partial standards are displayed on large LCD screen in preselected pairs of parameters as well as voltage, current and frequency readouts from built-in test signal meter.</p>
<p>OPEN and SHORT reference positions are also available.</p>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a style="color: #0000ff; text-decoration: underline;" href="http://rapid-tech.com.au/wp-content/uploads/2017/03/M550-Datasheet.pdf" target="_blank" rel="noopener">M550 Datasheet</a></span></span></h5>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a style="color: #0000ff; text-decoration: underline;" href="http://rapid-tech.com.au/wp-content/uploads/2017/03/M550-Operations-Manual.pdf" target="_blank" rel="noopener">M550 Operations Manual</a></span></span></h5>
<p>The post <a href="https://rapid-tech.com.au/meatest-m550-impedance-calibrator/">MEATEST M550 Impedance Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="justify">The philosophy behind the designing of the Meatest M550 Impedance Calibrator was to replace countless single value RCL standards with one calibrator that can switch between the standards like a CD changer in your car. The calibrator contains stable and temperature independent resistance standards, partial capacitance standards and partial inductance standards, simulated by RC T-type passive network. Calibration values of both complex parameters of partial standards are displayed on large LCD screen in preselected pairs of parameters as well as voltage, current and frequency readouts from built-in test signal meter. OPEN and SHORT reference positions are available as well.<br />
Easy recalibration system offers either full recalibration in all spot frequency points or simplified offset calibration. History of calibration values of partial standards at reference frequency 1 kHz can be easily recalled.</p>
<h3>Calibration domain</h3>
<p align="justify">MEATEST M550 Impedance Calibrator was designed for calibration of RCL meters in frequency range up to 1 MHz. The philosophy of M550 is based on remote control and automated calibration. For this reason, the calibrator is equipped with RS-232 and GPIB interfaces and of course, supported in CALIBER/WinQbase calibration software.</p>
<h3 align="justify">MEATEST M550 Impedance Calibrator Specifications:</h3>
<table class="vychoziTabulka" style="height: 184px;" width="395">
<tbody>
<tr>
<td>Resistance</td>
<td>100 mΩ &#8211; 100 MΩ, 20 Hz &#8211; 1 MHz<br />
± 0.02% / year @ 1 kHz</td>
</tr>
<tr>
<td>Capacitance</td>
<td>10 pF &#8211; 100 uF, 20 Hz &#8211; 1 MHz<br />
± 0.05% / year @ 1 kHz</td>
</tr>
<tr>
<td>Inductance</td>
<td>10 uH &#8211; 10 H, 20 Hz &#8211; 1 MHz<br />
simulated by T-network circuit<br />
± 0.1% / year @ 1 kHz</td>
</tr>
</tbody>
</table>
<h3>Test Signal Meter</h3>
<table class="vychoziTabulka" style="height: 160px;" width="399">
<tbody>
<tr>
<td>AC voltage</td>
<td>0.2 &#8211; 10 Vrms<br />
± 2% / year</td>
</tr>
<tr>
<td>AC current</td>
<td>1 nA &#8211; 500 mA<br />
± 2% / year</td>
</tr>
<tr>
<td>Frequency</td>
<td>20 Hz &#8211; 100 kHz<br />
± 100 ppm / year</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/meatest-m550-impedance-calibrator/">MEATEST M550 Impedance Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/meatest-m550-impedance-calibrator/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>MEATEST M133C Three Phase Power &#038; Energy Calibrator</title>
		<link>https://rapid-tech.com.au/meatest-m133c-three-phase-power-energy-calibrator/</link>
					<comments>https://rapid-tech.com.au/meatest-m133c-three-phase-power-energy-calibrator/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Mon, 20 Mar 2017 00:16:37 +0000</pubDate>
				<guid isPermaLink="false">http://rapid-tech.com.au/?post_type=product&#038;p=4818</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-28" src="http://rapid-tech.com.au/wp-content/uploads/2015/12/MEATEST_logo_PL.jpg" alt="MEATEST_logo_PL" width="125" height="28" /></p>
<p>The Meatest M133C Three Phase Power &#38; Energy Calibrator is compact all-in-one three phase power/energy calibrator. It can supply the unit under test with one phase accurate AC voltage and current with calibrated phase shift or DC voltage and current. Output voltage can be set in six ranges up to 600 V and output current in six ranges up to 30 A. Simulated electric power can be set independently in each phase. Frequency can be set in range from 15 Hz to 1 kHz with resolution 0.001 Hz to 0.01 Hz.</p>
<p>The M133C Calibrator is equipped with 5 1/2 digital DC meter with DC ranges 20 mA or 10 V for direct calibrating of various types of power transducers.</p>
<h4><span style="color: #ff0000;">Authorised Australian Distributor</span></h4>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2017/03/M133C-Datasheet.pdf" rel="noopener">M133C Datasheet</a></span></span></h5>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2017/03/Meatest-M133C-Operation-Manual.pdf" rel="noopener">Meatest M133C Operation Manual</a></span></span></h5>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2017/03/M133C-Application-Note.pdf" rel="noopener">M133C Application Note</a></span></span></h5>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/meatest-m133c-three-phase-power-energy-calibrator/">MEATEST M133C Three Phase Power &#038; Energy Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="justify">MEATEST M133C Three Phase Power &amp; Energy Calibrator is an AC/DC power and energy calibrator for calibration of power meters, power transducers, power quality analysers and generally all kinds of power measuring devices. AC voltage, current, power and energy functions have calibrated phase shift in frequency range from 15 Hz to 1 kHz with resolution as good as 0.001 Hz. Simulated electric power (including power quality functions) can be set independently in each phase of both voltage and current signals. Built-in 5½ process multimeter for transducer calibration is standard part of every M133C calibrator.</p>
<h3>Power quality functions</h3>
<p align="justify">MEATEST M133C Three Phase Power &amp; Energy Calibrator has four different distortion functions available:</p>
<ul>
<li>Harmonic distortion with up to 50 harmonic products</li>
<li>Interharmonic distortion up to 5000 Hz</li>
<li>Amplitude modulation using symetrical sine or square wave envelope and finally</li>
<li>dip/swell amplitude modulation using custom square wave envelope.</li>
</ul>
<p align="justify">Modulation frequency can be set in range from 0.001 Hz to 50 Hz, maximum modulation depth is 30 % and again, all the distortion parameters can be set independently for each phase.</p>
<h3>Calibration versatility</h3>
<p align="justify">The MEATEST M133C Three Phase Power &amp; Energy Calibrator is more than just a sophisticated power source. Using built-in process multimeter, both transducer inputs and outputs can be handled by the M133C at the same time so you can calibrate it more easily, using no other calibration equipment. Floating current outputs can be connected directly with voltage outputs to allow for 3-wire power meter calibration. One calibrator, many applications &#8211; saving your time, space and costs.</p>
<p>&nbsp;</p>
<div class="epyt-video-wrapper"><iframe loading="lazy"  id="_ytid_42303"  width="1020" height="574"  data-origwidth="1020" data-origheight="574"  data-relstop="1" src="https://www.youtube.com/embed/PRzdr0l561o?enablejsapi=1&#038;list=PL4n-l6oW25wlg2GfeNhC2-FOkhT5-nuEK&#038;autoplay=0&#038;cc_load_policy=0&#038;cc_lang_pref=&#038;iv_load_policy=1&#038;loop=0&#038;rel=0&#038;fs=1&#038;playsinline=1&#038;autohide=2&#038;theme=dark&#038;color=red&#038;controls=1&#038;disablekb=0&#038;" class="__youtube_prefs__  epyt-is-override  no-lazyload" title="M133C Three Phase Power and Energy Calibrator"  allow="fullscreen; accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen data-no-lazy="1" data-skipgform_ajax_framebjll=""></iframe></div>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>The post <a href="https://rapid-tech.com.au/meatest-m133c-three-phase-power-energy-calibrator/">MEATEST M133C Three Phase Power &#038; Energy Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/meatest-m133c-three-phase-power-energy-calibrator/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>MEATEST M160 Precision DC Calibrator</title>
		<link>https://rapid-tech.com.au/meatest-m160-precision-dc-calibrator/</link>
					<comments>https://rapid-tech.com.au/meatest-m160-precision-dc-calibrator/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Fri, 17 Mar 2017 21:38:28 +0000</pubDate>
				<guid isPermaLink="false">http://rapid-tech.com.au/?post_type=product&#038;p=4803</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-28" src="http://rapid-tech.com.au/wp-content/uploads/2015/12/MEATEST_logo_PL.jpg" alt="MEATEST_logo_PL" width="125" height="28" /></p>
<div class="productDetailText">
<p>MEATEST M160 Precision DC Calibrator is a 20 ppm calibrator of DC process signals designed for calibration of evaluation  process multimeters under demanding industrial conditions.</p>
<p><strong>Features:</strong></p>
</div>
<ul>
<li>20 ppm accuracy</li>
<li>13°C - 33°C reference temp. range</li>
<li>100 V @ 25 mA output capacity</li>
</ul>
<h4><span style="color: #ff0000;">Authorised Australian Distributor</span></h4>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a style="color: #0000ff; text-decoration: underline;" href="http://rapid-tech.com.au/wp-content/uploads/2017/03/M160-Datasheet.pdf" target="_blank" rel="noopener">M160 Datasheet</a></span></span></h5>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a style="color: #0000ff; text-decoration: underline;" href="http://rapid-tech.com.au/wp-content/uploads/2017/03/M160-Operation-Manual.pdf">M160 Operation Manual</a></span></span></h5>
<p>The post <a href="https://rapid-tech.com.au/meatest-m160-precision-dc-calibrator/">MEATEST M160 Precision DC Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="justify">The MEATEST M160 Precision DC Calibrator is a portable source of industrial process signals for calibration of multimeters in laboratories as well as on site calibration of evaluation units and other process meters. High load capacity of both voltage and current outputs, robust design and exceptional 20 ppm accuracy over 20°C-wide reference temperature range make this calibrator great for demanding conditions in production facilities. Other functions include thermocouple and RTD simulation, resistance and frequency, all with accuracy and resolution to meet all requirements. With option 91 the calibrator can measure temperature directly at output terminals and compensate the cold junction effect.</p>
<h3>User Friendly Operation</h3>
<p align="justify">As well as the MEATEST M160 Precision DC Calibrator industrial versatility, the calibrator is focused on user friendliness making calibrations simple and straightforward. Main parameters of both generated and measured signals are displayed on large LCD together with function-specific tooltip, providing all relevant details including range, accuracy or load limit. Inspired by recalibration simplicity of Meatest M6xx series, the MEATEST M160 Precision DC Calibrator can be easily calibrated using just its front keyboard without any mechanical adjustment inside the instrument.</p>
<p align="justify">The MEATEST M160 Precision DC Calibrator can be connected to various ATE systems via RS232, USB, LAN or GPIB interface and is fully compatible with WinQbase/Caliber calibration software including the CamOCR module for automated optical UUT readouts.</p>
<p align="justify"><strong>MEATEST M160 Specifications:</strong></p>
<table class="vychoziTabulka">
<tbody>
<tr>
<td>DC voltage</td>
<td>0 &#8211; 100 V, max. burden up to 2.5 W<br />
± 20 ppm / year</td>
</tr>
<tr>
<td>DC current</td>
<td>0 &#8211; 50 mA, max. burden up to 2.5 W<br />
± 50 ppm / year</td>
</tr>
<tr>
<td>Resistance</td>
<td>10 Ω &#8211; 300 kΩ, resolution from 100 uΩ<br />
± 200 ppm / year</td>
</tr>
<tr>
<td>Temperature</td>
<td>TC BEJKNRST with cold junction compensation<br />
RTD ± 0.1°C / year</td>
</tr>
<tr>
<td>Frequency</td>
<td>0.01 Hz &#8211; 15 kHz<br />
± 50 ppm / year</td>
</tr>
</tbody>
</table>
<h3>Process Meter</h3>
<table class="vychoziTabulka">
<tbody>
<tr>
<td>Frequency</td>
<td>0.01 Hz &#8211; 100 kHz<br />
± 50 ppm / year</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/meatest-m160-precision-dc-calibrator/">MEATEST M160 Precision DC Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/meatest-m160-precision-dc-calibrator/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>MEATEST M143 Portable Multifunction Calibrator</title>
		<link>https://rapid-tech.com.au/meatest-m143-portable-multifunction-calibrator/</link>
					<comments>https://rapid-tech.com.au/meatest-m143-portable-multifunction-calibrator/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Fri, 17 Mar 2017 05:38:12 +0000</pubDate>
				<guid isPermaLink="false">http://rapid-tech.com.au/?post_type=product&#038;p=4781</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-28" src="http://rapid-tech.com.au/wp-content/uploads/2015/12/MEATEST_logo_PL.jpg" alt="MEATEST_logo_PL" width="125" height="28" /></p>
<p>The MEATEST M143 Portable multifunction calibrator is cost saving solution for calibration of meters with ranges up to 1000 V and 20 A. Basic accuracy of 65 ppm in DC voltage is more than enough for calibration of 3½ and 4½ digit multimeters. Resistance function is covered by eight fix resistors in range from 10 Ω to 100 MΩ, other features are TC temperature sensor simulation and optionally RTD temperature sensor simulation. Thanks to its small dimensions and low weight the calibrator is ideal for field calibrations.</p>
<h5><span style="color: #ff0000;">Authorised Australian Distributor</span></h5>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline;"><span style="color: #0000ff; text-decoration: underline;"><a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2017/03/M143-Datasheet.pdf" rel="noopener">M143 Datasheet</a></span></span></h5>
<h5><img class="alignnone size-full wp-image-4322" src="http://rapid-tech.com.au/wp-content/uploads/2016/09/pdf.jpg" alt="pdf" width="55" height="56" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a target="_blank" href="http://rapid-tech.com.au/wp-content/uploads/2017/03/M143-Operations-Manual.pdf" rel="noopener">M143 Operations Manual</a></span></span></h5>
<p>&#160;</p>
<p>The post <a href="https://rapid-tech.com.au/meatest-m143-portable-multifunction-calibrator/">MEATEST M143 Portable Multifunction Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="justify">The MEATEST M143 Portable multifunction calibrator is cost saving solution for calibration of meters of electric quantities up to 1000 V and 20 A. Basic accuracy of 65 ppm in DC voltage is more than enough for calibration of 3½ and 4½ digit multimeters. Resistance function is covered by eight fix resistors in range from 10 Ω to 100 MΩ, other features are TC temperature sensor simulation and optionally RTD temperature sensor simulation. Thanks to its small dimensions and low weight the calibrator is ideal for field calibrations.</p>
<h2>Calibration domain</h2>
<p align="justify">The MEATEST M143 Portable Multifunction Calibrator was designed for automated calibrations at production lines of panel meters, multimeters, transducers, measuring amplifiers, thermometers, and calibration laboratories where the calibrator can be applied as source of standard value for calibrations, verifications and adjustments of units under test.<br />
RS-232 and optionally GPIB interface allow for remote control of the calibrator and time saving automated calibrations using SW package CALIBER/WinQbase.</p>
<p>&nbsp;</p>
<p><iframe loading="lazy" width="1020" height="574" src="https://www.youtube.com/embed/lkLtfKD20CY?feature=oembed" frameborder="0" allow="autoplay; encrypted-media" allowfullscreen></iframe></p>
<h4>MEATEST M143 Portable Multifunction Calibrator Specifications:</h4>
<table class="vychoziTabulka">
<tbody>
<tr>
<td>DC voltage</td>
<td>0 &#8211; 1000 V<br />
± 60 ppm / year</td>
</tr>
<tr>
<td>AC voltage</td>
<td>1 mV &#8211; 1000 V, 20 Hz &#8211; 10 kHz<br />
sinusoidal &amp; non-sinusoidal waveforms<br />
± 500 ppm / year</td>
</tr>
<tr>
<td>DC current</td>
<td>0 &#8211; 20 A (1000 A with 140-50 Current Coil)<br />
± 150 ppm / year</td>
</tr>
<tr>
<td>AC current</td>
<td>1 uA &#8211; 20 A, 20 Hz &#8211; 1 kHz (1000 A with 140-50 Current Coil)<br />
sinusoidal &amp; non-sinusoidal waveforms<br />
± 700 ppm / year</td>
</tr>
<tr>
<td>Resistance</td>
<td>10 Ω &#8211; 100 MΩ, 8 fixed values<br />
± 200 ppm / year</td>
</tr>
<tr>
<td>Temperature</td>
<td>TC BEJKNRST with cold junction compensation<br />
RTD ± 0.1°C / year</td>
</tr>
<tr>
<td>Frequency</td>
<td>0.1 Hz &#8211; 2 MHz<br />
± 100 ppm / year</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://rapid-tech.com.au/meatest-m143-portable-multifunction-calibrator/">MEATEST M143 Portable Multifunction Calibrator</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rapid-tech.com.au/meatest-m143-portable-multifunction-calibrator/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
