	<title>Additel Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/brand/additel/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/brand/additel/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Wed, 18 Feb 2026 01:12:49 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>Additel Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/brand/additel/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Additel ADT992 Pneumatic Pressure Pump &#124; 50 Bar Calibration</title>
		<link>https://rapid-tech.com.au/additel-adt992-pneumatic-pressure-pump-50-bar-calibration/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Fri, 13 Feb 2026 02:38:13 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=1119102</guid>

					<description><![CDATA[<p><img class="alignnone wp-image-28419" src="https://rapid-tech.com.au/wp-content/uploads/2024/10/images.png" alt="additel logo" width="177" height="76" /></p>
<p><a target="_blank" href="https://mymeter.com.au/product/additel-adt992-pneumatic-pressure-pump-50-bar-calibration" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Professional handheld pneumatic pressure pump generating 95% vacuum to 700 psi (50 bar).</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Dual-stage piston with lever pressurization for rapid stabilization. Multi-position versatility suits confined spaces. Includes quick connectors and filters.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Australian stock with calibration certification available.</p>
<h4><img class="alignnone size-full wp-image-19718" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/PDF-blue.png" alt="PDF Download" width="43" height="54" /> <a target="_blank" href="https://rapid-tech.com.au/wp-content/uploads/2026/02/Additel-992-Datasheet.pdf" rel="noopener">Additel 992 Datasheet</a></h4>
<p>The post <a href="https://rapid-tech.com.au/additel-adt992-pneumatic-pressure-pump-50-bar-calibration/">Additel ADT992 Pneumatic Pressure Pump | 50 Bar Calibration</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 class="text-text-100 mt-3 -mb-1 text-[1.375rem] font-bold">Additel ADT992 Handheld Pneumatic Pressure Pump – Portable Vacuum to 50 Bar Calibration System</h2>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Stop Fighting Unstable Pressure During Critical Calibrations</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">You&#8217;re on-site calibrating pressure transmitters, and your traditional hand pump is making you work twice as hard. You&#8217;re pumping frantically to reach 30 bar, the pressure keeps drifting, and you&#8217;re burning valuable time trying to maintain stability long enough to record a reading. Meanwhile, your client&#8217;s production team is waiting for you to finish, and you&#8217;re questioning whether your calibration certificate will hold up under scrutiny.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The Additel ADT992 Handheld Pneumatic Pressure Pump eliminates this frustration. Designed specifically for field calibration professionals, this pump delivers consistent pressure generation from 95% vacuum to 700 psi (50 bar) – covering the vast majority of industrial pneumatic calibration requirements across Australian HVAC, compressed air, and process instrumentation applications.</p>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Dual-Stage Engineering: Work Smarter, Not Harder</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The ADT992&#8217;s dual-stage piston design fundamentally changes how you approach pressure calibration. The pre-pressure piston rapidly builds bulk pressure with minimal physical effort – you&#8217;ll reach 40 bar faster than with conventional hand pumps, without the arm fatigue. Once you&#8217;re approaching your target pressure, the fine adjustment screw (7.2 ml volume capacity) provides precise control for hitting exact calibration points.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Each lever stroke delivers a +30 psi (2 bar) boost, giving you predictable, controlled pressure increases. The 10 Pa (0.1 mbar) adjustment resolution means you can dial in precise pressure values required for tight-tolerance calibrations. This isn&#8217;t just convenient – it&#8217;s the difference between completing 10 calibrations per day versus 6, and arriving home without exhausted forearms.</p>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Built-In Vacuum Capability: One Pump, Complete Pressure Range</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Unlike basic pressure-only hand pumps, the ADT992 generates vacuum down to 95% (approximately -950 mbar), making it genuinely versatile for calibration technicians who work with both positive pressure and vacuum instruments. Calibrating vacuum switches, negative pressure transmitters, or differential pressure devices no longer requires carrying separate equipment.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The minimum pre-pressure of 600 psi (40 bar) means you can efficiently generate high pressures without excessive pumping cycles, while the 35 ml maximum load volume provides the capacity needed for testing larger-volume pressure systems without constant re-pumping.</p>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Multi-Position Versatility: Designed for Real Job Sites, Not Just Lab Benches</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Australian trade professionals work in cramped plant rooms, alongside running machinery, on elevated platforms, and in confined spaces where traditional hand pumps become awkward or impossible to operate effectively. Additel engineered the ADT992 with this reality in mind.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The adjustable reference port and dual rubber grips enable horizontal, vertical, or tilted operation – whatever orientation suits your specific installation. Calibrating a wall-mounted pressure transmitter at head height? Work vertically. Testing equipment on a workbench? Operate horizontally. Awkward installation in a tight mechanical room? Adjust the pump to whatever position gives you access.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">At just 1.6 kg (3.5 lbs) and measuring 320mm x 110mm x 122mm (base x width x height), the ADT992 fits in your toolkit alongside multimeters and clamp meters, not in a separate bulky case that stays in the van.</p>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Integrated Filtration Protects Your Calibration Standards</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The ADT992 includes built-in port filters that protect both your pump and your precision calibration instruments:</p>
<ul class="[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3">
<li class="whitespace-normal break-words pl-2"><strong>Standard port:</strong> 150μm quick-removal filter prevents contamination entering your reference gauge or calibrator</li>
<li class="whitespace-normal break-words pl-2"><strong>Pump air intake port:</strong> 100μm quick-removal filter protects internal components from dust and debris</li>
<li class="whitespace-normal break-words pl-2"><strong>Pressure outlet:</strong> 150μm quick-release filter ensures clean pressure delivery to your device under test</li>
</ul>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">These filters are critical when working in dusty industrial environments, mining facilities, or outdoor installations where airborne contamination would otherwise compromise measurement accuracy or damage sensitive instruments. The quick-removal design means you can clean or replace filters on-site without tools.</p>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Hand-Tight Quick Connectors: Faster Workflows, No Tools Required</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Every model includes the ADT100-X-FNG female quick connector for your device under test (DUT), with configurations available in 1/4NPT, 1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5 to match your specific equipment. The hand-tight design means you can swap between different instruments without reaching for spanners – critical when you&#8217;re rotating through multiple calibration points or testing several devices in succession.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">When you&#8217;re working through a calibration schedule with 15 pressure transmitters to verify, these seconds per connection add up to significant time savings across your day.</p>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Materials and Construction: Built for Australian Industrial Environments</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The ADT992 uses stainless steel ram/adapters and a combination SS/aluminium body construction with Buna-N, PTFE, and Copper Alloy seals – materials selected for durability, chemical resistance, and reliable performance across diverse Australian conditions.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Whether you&#8217;re working in tropical Queensland humidity, dry inland mining facilities, coastal industrial plants with salt air, or temperature-controlled metropolitan facilities, the custom-machined components maintain leak-free operation. The robust construction withstands the inevitable knocks from being transported between sites, dropped in toolboxes, or used on vibrating equipment platforms.</p>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Applications Across Australian Industrial and Trade Sectors</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>HVAC &amp; Refrigeration Technicians:</strong> Verify pressure switches on commercial HVAC systems, test refrigeration gauges, calibrate building automation pressure sensors. The vacuum capability handles negative pressure differential switches common in HVAC applications.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Industrial Maintenance Teams:</strong> Routine calibration of pneumatic pressure transmitters, compressed air gauges, process control instruments, and safety devices. The multi-position capability handles installations in machinery bays, overhead piping, or confined equipment rooms.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Calibration Technicians:</strong> On-site verification services, field calibrations, and workshop instrument testing up to 50 bar. Pair with your Additel pressure calibrator or reference gauge for complete NATA-traceable pressure calibration capability.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Compressed Air System Specialists:</strong> Testing and verification of compressor pressure switches, airline pressure gauges, and pneumatic control equipment across manufacturing facilities, workshops, and industrial plants.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Instrumentation Engineers:</strong> Commissioning new pressure instruments, verifying process control transmitters, and maintaining measurement accuracy for compliance reporting. The stable pressure generation and fine adjustment support precise calibration procedures required for audit documentation.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Test &amp; Measurement Professionals:</strong> Pressure instrument audits, pre-calibration checks, equipment verification, and compliance testing for quality management systems. The 1-year warranty and available maintenance kit support long-term accuracy and reliability.</p>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">What&#8217;s Actually Included: Complete Calibration Kit</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The ADT992 arrives ready for professional calibration work:</p>
<ul class="[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3">
<li class="whitespace-normal break-words pl-2">ADT992 handheld pneumatic pressure pump with your selected pressure port type</li>
<li class="whitespace-normal break-words pl-2">Female quick connector for DUT connection (specified by your port configuration)</li>
<li class="whitespace-normal break-words pl-2">20 x O-rings for maintenance and seal replacement</li>
<li class="whitespace-normal break-words pl-2">Flexible pressure hose (maximum pressure rating: 630 bar)</li>
<li class="whitespace-normal break-words pl-2">Built-in port filters (standard port, pump intake, pressure outlet)</li>
</ul>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>ADT992-X-SET models</strong> additionally include a carrying case for protected transport between job sites.</p>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Optional Accessories for Extended Capability</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>ADT102 Adapter Set:</strong> 25-piece kit with 1/4NPT male adapters to various male and female connections – covers the majority of pressure instrument fittings you&#8217;ll encounter across different manufacturers.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>ADT103 Quick Connector Set:</strong> 10-piece kit with hand-tight quick connectors in multiple configurations (1/2NPT, 1/4BSP, 1/2BSP, M20X1.5) – enables rapid connection to diverse pressure equipment without thread compatibility concerns.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>9901-992 Carrying Case:</strong> Protective case for one ADT992 pump – safeguards your equipment during transport and provides organized storage.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>ADT992/993-MK Maintenance Kit:</strong> Replacement seals, O-rings, and service components for long-term pump maintenance – maintains performance and extends operational life.</p>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Model Selection Guide: Choose Your Pressure Port Configuration</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The ADT992 is available with different pressure port types to match your existing equipment and regional standards:</p>
<ul class="[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3">
<li class="whitespace-normal break-words pl-2"><strong>ADT992-N:</strong> 1/4NPT female port (common in Australia, North America)</li>
<li class="whitespace-normal break-words pl-2"><strong>ADT992-N2:</strong> 1/2NPT female port (larger bore for higher flow applications)</li>
<li class="whitespace-normal break-words pl-2"><strong>ADT992-B:</strong> 1/4BSP female port (British Standard Pipe, common in older Australian industrial equipment)</li>
<li class="whitespace-normal break-words pl-2"><strong>ADT992-B2:</strong> 1/2BSP female port</li>
<li class="whitespace-normal break-words pl-2"><strong>ADT992-M:</strong> M20X1.5 female port (metric thread, common in European-manufactured equipment)</li>
</ul>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">If you work across facilities with mixed equipment standards, consider the ADT103 quick connector accessory set for maximum versatility.</p>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Australian Supply with Calibration Support</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">We understand Australian calibration professionals need more than just equipment – you need traceable certification, responsive support, and confidence that your tools meet compliance requirements. Our Australian stock ensures fast delivery, while our calibration capabilities provide NATA-traceable certification when required for your quality management systems.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Whether you&#8217;re maintaining instruments to AS 2593 (boiler pressure vessel standards), supporting AS/NZS 3788 (pressure equipment compliance), or documenting calibrations for ISO 9001 quality systems, we understand the certification and traceability requirements Australian professionals face.</p>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Why Choose the Additel ADT992?</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Efficiency:</strong> Dual-stage design with lever pressurization generates pressure 40% faster than conventional hand pumps with significantly less physical effort.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Versatility:</strong> 95% vacuum to 700 psi (50 bar) range covers pneumatic transmitters, compressed air gauges, HVAC pressure switches, vacuum instruments, and general industrial pressure calibration requirements.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Precision:</strong> 10 Pa (0.1 mbar) adjustment resolution with 7.2 ml fine adjustment volume enables exact calibration point targeting.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Stability:</strong> Lever mechanism provides superior pressure stability compared to screw-type hand pumps – critical for recording accurate calibration readings.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Portability:</strong> 1.6 kg weight and compact dimensions suit daily field use without toolkit bulk or transport hassles.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Durability:</strong> Stainless steel and aluminium construction with engineered seals ensures leak-free operation across diverse Australian industrial environments.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Protection:</strong> Integrated 100-150μm port filters protect both your calibration standards and the pump from contamination damage.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Flexibility:</strong> Multi-position operation (horizontal, vertical, tilted) handles real-world installation constraints and confined workspace limitations.</p>
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Ready for Professional-Grade Pressure Calibration?</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Whether you&#8217;re conducting routine instrument verifications, commissioning new pressure equipment, or maintaining critical process instrumentation, the Additel ADT992 delivers the portable pressure generation capability modern calibration work demands. Fast pressure generation, precise control, genuine vacuum capability, and the reliability Australian trade professionals expect – backed by local stock and calibration support.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h2 class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold">Technical Specifications</h2>
<div class="overflow-x-auto w-full px-2 mb-6">
<table class="min-w-full border-collapse text-sm leading-[1.7] whitespace-normal">
<thead class="text-left">
<tr>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold">Specification</th>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold">Value</th>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold">What This Means for Your Work</th>
</tr>
</thead>
<tbody>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Pressure Range</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">95% vacuum to 700 psi (50 bar)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Covers pneumatic transmitters, compressed air, HVAC, and vacuum instruments</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Media</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Air (pneumatic)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Suitable for gas/air pressure calibration applications</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Adjustment Resolution</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">10 Pa (0.1 mbar)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Precise targeting of exact calibration points</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Minimum Pre-pressure</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">600 psi (40 bar)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Efficient high-pressure generation without excessive pumping</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Boost Pressure per Stroke</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">+30 psi (2 bar) / stroke</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Predictable, controlled pressure increases</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Maximum Load Volume</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">35 ml</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Capacity for testing larger-volume pressure systems</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Fine Adjustment Volume</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">7.2 ml</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Precision control range for exact pressure values</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Pressure Generation</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Dual-stage piston</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Pre-pressure stage + fine adjustment for efficiency</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Pressurization Method</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Lever-type</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Quick stabilization with minimal physical effort</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Weight</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">1.6 kg (3.5 lbs)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Genuinely portable for daily field use</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Dimensions (Base)</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">12.6&#8243; (320mm) x 4.3&#8243; (110mm)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Compact footprint fits standard toolboxes</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Height</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">4.8&#8243; (122mm)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Low profile for transport and storage</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Operating Positions</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Horizontal, Vertical, Tilted</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Adjustable for confined spaces and awkward installations</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Reference Port</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Adjustable</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Repositionable for multi-position operation</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Grip Design</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Dual rubber grips</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Secure handling in various orientations</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Port Filters</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">100-150μm quick-removal</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Protection from contamination (standard, intake, outlet)</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>DUT Connection</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Hand-tight quick connector</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Tool-free device changeover</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Available Port Types</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">1/4NPT, 1/2NPT, 1/4BSP, 1/2BSP, M20X1.5 female</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Match your equipment and regional standards</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Body Material</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">SS, Aluminium</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Durable, corrosion-resistant construction</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Ram/Adapters Material</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Stainless Steel (SS)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Wear-resistant, chemically compatible</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Seals Material</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Buna-N, PTFE, Copper Alloy</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Chemical resistance and reliable sealing</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Included Accessories</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Female quick connector, 20 x O-rings, flexible hose</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Ready for immediate use</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Flexible Hose Rating</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Maximum pressure: 630 bar</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Exceeds pump capability for safety margin</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Warranty</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">1 year</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Manufacturer-backed reliability assurance</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Optional Carrying Case</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">9901-992 (for -SET models)</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Protected transport between job sites</td>
</tr>
</tbody>
</table>
</div>