<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Acoustic Imagers Archives - rapid-tech</title>
	<atom:link href="https://rapid-tech.com.au/acoustic-imagers/feed/" rel="self" type="application/rss+xml" />
	<link>https://rapid-tech.com.au/acoustic-imagers/</link>
	<description>Test Equipment Supplier</description>
	<lastBuildDate>Tue, 30 Jun 2026 03:38:58 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.5</generator>

<image>
	<url>https://rapid-tech.com.au/wp-content/uploads/2023/11/cropped-Rapid-Tech-logo-blue-1-1-32x32.png</url>
	<title>Acoustic Imagers Archives - rapid-tech</title>
	<link>https://rapid-tech.com.au/acoustic-imagers/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Fluke iSee ii01 Acoustic Imaging Camera &#124; Smartphone Leak Detector &#124; Australia</title>
		<link>https://rapid-tech.com.au/fluke-isee-ii01-acoustic-imaging-camera/</link>
		
		<dc:creator><![CDATA[Sam Hewa]]></dc:creator>
		<pubDate>Tue, 30 Jun 2026 03:09:22 +0000</pubDate>
				<guid isPermaLink="false">https://rapid-tech.com.au/?post_type=product&#038;p=1119375</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-679" src="https://rapid-tech.com.au/wp-content/uploads/2020/07/Fluke-Logo-Small.png" alt="" width="200" height="67" /></p>
<p><a target="_blank" href="https://mymeter.com.au/product/fluke-isee-ii01-acoustic-imaging-camera/" rel="noopener"><img class="alignnone wp-image-17839" src="https://rapid-tech.com.au/wp-content/uploads/2021/04/BUY-NOW-form-My-Meter-e1620004731558.png" alt="BUY NOW form My Meter" width="160" height="40" /></a></p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="15:1-15:469;423-891">The Fluke iSee™ ii01 turns your Android smartphone into a professional acoustic imaging system — no training required, no bulky gear, no downtime for the line. Simply plug it into your phone's USB-C port and Fluke's SoundMap™ technology immediately visualises compressed air leaks, gas escapes, and mechanical abnormalities across a wide 2 kHz–48 kHz frequency range. At just 50 g, it's the acoustic expert that lives in your pocket. Backed by Fluke's 2-year warranty.</p>
<p data-sourcepos="15:1-15:469;423-891"><img class="alignnone size-full wp-image-6653" src="https://mymeter.com.au/wp-content/uploads/2018/10/PDF-blue.png" alt="PDF download" width="43" height="54" /> <a target="_blank" href="https://media.fluke.com/aad750c1-b7e5-4ab7-a7a6-b41e0128914c_original file.pdf" rel="noopener">Datasheet</a></p>
<p data-sourcepos="15:1-15:469;423-891"><img class="alignnone size-full wp-image-6653" src="https://mymeter.com.au/wp-content/uploads/2018/10/PDF-blue.png" alt="PDF download" width="43" height="54" /> <a target="_blank" href="https://media.fluke.com/be9f75f5-ea06-4ae3-97c8-b41e010cfd55_original file.pdf" rel="noopener">User Manual</a></p>
<p>The post <a href="https://rapid-tech.com.au/fluke-isee-ii01-acoustic-imaging-camera/">Fluke iSee ii01 Acoustic Imaging Camera | Smartphone Leak Detector | Australia</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="21:1-21:49;934-982">The Problem with Finding What You Can&#8217;t Hear</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="23:1-23:396;984-1379">Compressed air and gas leaks are some of the most expensive problems in Australian manufacturing and process facilities — and they&#8217;re almost entirely invisible. You can&#8217;t see them. You usually can&#8217;t hear them above the ambient noise of a working plant. And by the time a leak becomes obvious, the cost in wasted energy and compromised system pressure has already accumulated for weeks or months.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="25:1-25:435;1381-1815">Traditional approaches have real limitations. Soap-water bubble testing means coating every joint by hand and waiting. Single-sensor ultrasonic detectors require slow, row-by-row scanning and struggle at distances. Dedicated acoustic imaging systems solve both problems brilliantly, but they&#8217;ve historically carried price tags that restrict them to one shared instrument for an entire organisation — if any budget is available at all.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="27:1-27:346;1817-2162">The Fluke iSee™ ii01 changes the equation. It&#8217;s an entry-level acoustic imaging camera that plugs directly into the USB-C port of any compatible Android or HarmonyOS smartphone, transforming a device that&#8217;s already in your pocket into a professional-grade SoundMap™ imaging system. Point. Scan. Locate. Done — often in minutes rather than hours.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="31:1-31:51;2169-2219">How the ii01 Works: Acoustic Imaging Explained</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="33:1-33:234;2221-2454">When compressed air or gas escapes through a small opening, the turbulence generated produces ultrasonic sound waves above 20 kHz — far beyond the range of human hearing, but well within the detection band of the ii01&#8217;s sensor array.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="35:1-35:514;2456-2969">The ii01 uses 16 high-precision MEMS microphones arranged in an array to capture those ultrasonic signals from multiple directions simultaneously. Fluke&#8217;s proprietary SoundMap™ beamforming algorithm then calculates the precise origin of the sound and overlays a colour-coded acoustic heat map directly onto the live camera image on your phone screen. The loudest source — the likely leak point — appears as a bright hot spot on your display, at distances from 0.5 m right out to 50 m depending on site conditions.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="37:1-37:307;2971-3277">Because most industrial equipment produces low-frequency background noise while gas leaks generate high-frequency ultrasonic signatures, the ii01 can reliably distinguish leak signals even in noisy operating environments. Scans can be performed while equipment is running — no production shutdown required.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="41:1-41:34;3284-3317">SoundMap™ Leak Detection Mode</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="43:1-43:417;3319-3735">For frontline leak detection tasks, the ii01 includes a dedicated Quick Leak Detection mode that locks the frequency band to 37.4 kHz–42.6 kHz (the optimal ultrasonic range for compressed air and gas leak signatures) with a single tap. Real-time dB values for the target centre point are displayed on screen, giving technicians an immediate quantitative indicator to help assess leak severity and prioritise repairs.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="45:1-45:243;3737-3979">For broader acoustic investigation — locating mechanical abnormalities, assessing air tightness on complex pipeline assemblies, or noise source identification — the full 2 kHz to 48 kHz frequency range is available with manual slider control.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="47:1-47:285;3981-4265">Three colour palette options (IronRed, Blue-Red, and Grayscale) with fully adjustable colour blending (0–100%) give you control over how the acoustic overlay appears against the visible image, making it easy to adapt display settings to different lighting conditions and environments.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="51:1-51:39;4272-4310">Built for the Realities of the Job</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="53:1-53:84;4312-4395">The ii01 was designed with working maintenance teams in mind, not lab environments.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="55:1-55:292;4397-4688"><strong>Plug and play, no setup overhead.</strong> Connect the ii01 to your smartphone&#8217;s USB-C port and open the Fluke iSee™ app — you&#8217;re imaging immediately. No batteries to charge, no boot sequence, no configuration menus to navigate before you can start. The ii01 draws power directly from your phone.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="57:1-57:260;4690-4949"><strong>50 grams. Pocket-sized.</strong> The all-aluminium housing measures just 61 × 50 × 12 mm and weighs 50 g — lighter than most multi-tools and far smaller than any standalone acoustic imager on the market. Drop it in a shirt pocket and carry it to every job on site.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="59:1-59:306;4951-5256"><strong>No buttons to learn.</strong> The minimalist hardware design means there&#8217;s nothing to accidentally press or configure. All controls are handled through the simplified iSee™ app UI, which is designed for fast, intuitive operation by technicians who need to get results rather than learn a new software platform.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="61:1-61:424;5258-5681"><strong>Share findings instantly.</strong> Images (JPG) and videos (MP4, up to 5 minutes) are saved directly to your phone&#8217;s photo library with customisable watermarks for documentation purposes. Share them via text, email, or any messaging platform without needing to transfer files to a computer. For maintenance teams that need to escalate findings or brief supervisors while still on the floor, that immediacy is genuinely valuable.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="63:1-63:144;5683-5826"><strong>IP54 ingress protection.</strong> Rated to IEC 60529 IP54, the ii01 handles the dust and light moisture exposure typical in industrial environments.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="67:1-67:57;5833-5889">Where the ii01 Delivers Value in Australian Industry</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="69:1-69:440;5891-6330"><strong>General manufacturing and process facilities.</strong> Compressed air systems typically account for a significant portion of facility energy consumption. Poorly maintained systems can waste a substantial fraction of compressed air output through undetected leaks. The ii01 lets maintenance technicians walk a production area, rapidly scanning for leaks — without interrupting operations — and document findings for a scheduled repair programme.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="71:1-71:333;6332-6664"><strong>Injection moulding and plastics.</strong> Compressed air leak detection in injection moulding machines is a primary application. Leaks reduce system pressure, reducing pneumatic tool efficiency and introducing variability into production quality. The ii01 locates the source visually rather than requiring section-by-section disassembly.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="73:1-73:268;6666-6933"><strong>Energy storage and battery manufacturing.</strong> Pre-commissioning pipeline air tightness testing on energy storage cabinets is a documented use case. The ii01 can scan complex pipeline assemblies quickly before equipment leaves the factory, confirming system integrity.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="75:1-75:356;6935-7290"><strong>Chemical, gas, and metallurgical plants.</strong> Process gas leak detection on chemical reactors, pressure vessels, and piping systems operating under high-pressure or high-temperature conditions. The ii01&#8217;s non-contact imaging capability means technicians can scan from a safe working distance rather than approaching potentially hazardous pipework directly.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="77:1-77:183;7292-7474"><strong>Food, beverage, and pharmaceutical production.</strong> Hygiene-critical environments where rapid non-contact detection and documented reporting are part of standard maintenance practice.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="79:1-79:167;7476-7642"><strong>Refrigeration and HVAC.</strong> Compressor and refrigeration equipment leak assessments, where gas tightness directly impacts system efficiency and regulatory compliance.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="81:1-81:219;7644-7862"><strong>Facilities management.</strong> Building air tightness inspections and mechanical plant maintenance assessments, where a lightweight, easy-to-use device is far more practical than booking out a shared specialist instrument.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="85:1-85:62;7869-7930">Comparing the ii01 to Higher-End Acoustic Imaging Systems</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="87:1-87:439;7932-8370">The ii01 is the entry point to Fluke&#8217;s acoustic imaging range — specifically designed to be accessible to individual technicians and smaller maintenance teams rather than requiring a shared, high-investment instrument. It delivers qualitative SoundMap™ imaging and single-source identification (the point with the highest acoustic energy) across the 2–48 kHz band, with leak mode, real-time dB display, and full image/video documentation.</p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="89:1-89:506;8372-8877">Fluke&#8217;s higher-tier ii500, ii905, and ii915 series instruments add capabilities including multi-source acoustic imaging, preliminary quantitative analysis modes (LeakQ, PDQ, MecQ), wider frequency ranges, and advanced analytical tools suited to systematic reliability programmes. The ii01 is not a replacement for those instruments — but for organisations looking to put acoustic imaging capability in the hands of every maintenance technician at an affordable per-unit cost, it&#8217;s a compelling first step.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<p><strong>Unparalleled usability</strong></p>
<table class="table">
<tbody>
<tr>
<td><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-1121764" src="https://mymeter.com.au/wp-content/uploads/2026/06/imgi_13_30ce4dca-410b-4cca-9f70-b412010a6f59_original-file.webp" alt="" width="450" height="600" /></td>
<td><img decoding="async" class="alignnone size-full wp-image-1121765" src="https://mymeter.com.au/wp-content/uploads/2026/06/imgi_14_efb92515-ec39-4c61-b3b2-b412010a7021_original-file.webp" alt="Fluke ii01 acoustic camera showing IronRed SoundMap heat map on injection moulding machine" width="450" height="600" /></td>
<td><img decoding="async" class="alignnone size-full wp-image-1121766" src="https://mymeter.com.au/wp-content/uploads/2026/06/imgi_15_f40ed812-5ddf-4245-ad5b-b412010a6e84_original-file.webp" alt="Fluke ii01 acoustic camera detecting compressed air leak on industrial pipeline — Australia" width="450" height="600" /></td>
</tr>
<tr>
<td>Compressed air leak detection of injection molding machines</td>
<td>Air tightness inspection of complicated equipment pipelines</td>
<td>Pipeline leak detection</td>
</tr>
</tbody>
</table>
<hr />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="93:1-93:15;8884-8898">In the Box</h3>
<ul class="[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3" data-sourcepos="95:1-97:24;8900-9003">
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="95:1-95:52;8900-8951">Fluke ii01 Acoustic Camera for Android Smartphone</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="96:1-96:28;8952-8979">Soft protective carry bag</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2" data-sourcepos="97:1-97:24;8980-9003">Quick Reference Guide</li>
</ul>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="99:1-99:159;9005-9163"><em>Requires: Compatible Android (6.0+) or HarmonyOS (2.0+) smartphone with USB-C port and OTG enabled. Download the Fluke iSee™ app from the Google Play Store.</em></p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h2 class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold" data-sourcepos="103:1-103:34;9170-9203">TECHNICAL SPECIFICATIONS TABLE</h2>
<div class="overflow-x-auto w-full px-2 mb-6" data-sourcepos="105:1-133:53;9205-12638">
<table class="min-w-full border-collapse text-sm leading-[1.7] whitespace-normal">
<thead class="text-left">
<tr>
<th class="text-text-100 border-b-0.5 border-[hsl(var(--border-300)/0.6)] py-2 pr-4 align-top font-bold" scope="col">Specification</th>
<th class="text-text-100 border-b-0.5 border-[hsl(var(--border-300)/0.6)] py-2 pr-4 align-top font-bold" scope="col">Value</th>
<th class="text-text-100 border-b-0.5 border-[hsl(var(--border-300)/0.6)] py-2 pr-4 align-top font-bold" scope="col">Why It Matters</th>
</tr>
</thead>
<tbody>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Microphones</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">16 high-precision MEMS sensors</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Multi-sensor array enables directional acoustic imaging (beamforming) — single-sensor detectors cannot locate leaks visually</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Frequency band</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">2 kHz to 48 kHz</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Covers both low-frequency mechanical noise and high-frequency gas leak signatures across a single device</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Quick Leak Detection mode</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Locks at 37.4–42.6 kHz</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Optimised for compressed air and gas leak detection with a single tap; removes guesswork about frequency selection</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>dB value display</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Target centre point; enable/disable</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Real-time quantitative indicator supports severity assessment and repair prioritisation on site</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Detection range</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">0.50 m to 50 m (site-dependent)</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Wide standoff range lets you scan from a safe distance, including hard-to-reach or elevated pipework</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Field of view</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">50° (H) × 38° (V)</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Wide angular coverage means less repositioning when scanning large equipment or panel arrays</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Frame rate</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">20 Hz</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Smooth, responsive acoustic image — not a static snapshot</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Sensitivity</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">−38 dBV</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">High sensitivity MEMS sensors detect low-level leak signatures that lower-sensitivity detectors would miss</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Signal-to-noise ratio</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">73 dBA</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Strong SNR means the ii01 can distinguish real leak signals even in noisy industrial environments</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Visible lens resolution</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">2 MP</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Background image is sharp enough for accurate overlay interpretation and documentation</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Acoustic image</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Fluke SoundMap™</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Proprietary Fluke technology for overlaying directional acoustic data onto the live camera view</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Focal length</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">50 cm to infinity</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Set-and-forget focus — no adjustment needed across typical industrial inspection distances</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Image format</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">JPG / MP4 (up to 5 min)</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Saves directly to phone library; no separate software or USB transfer required</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Colour palettes</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">IronRed, Blue-Red, Grayscale</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Three options with 0–100% blending for different viewing environments</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Customised watermark</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Image or text characters</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Branded documentation directly from the device — no post-processing required</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Interface</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">USB Type-C</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Direct phone connection; powers from phone — no separate battery or charger</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>OS supported</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Android 6.0+ / HarmonyOS 2.0+</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Compatible with a broad range of current Android devices</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Ingress protection</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">IP54 (IEC 60529)</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Dust-partial and splash-resistant for industrial use</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Operating temperature</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">0 °C to +40 °C</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Suitable for standard industrial and outdoor Australian environments</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Storage temperature</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">−30 °C to +60 °C</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Handles vehicle storage and warehouse temperature extremes</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Operating humidity</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">10–90% RH, non-condensing</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Suitable for humid manufacturing and food production environments</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Operating altitude</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Up to 2,000 m</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Covers most Australian industrial sites including highland mining</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Power consumption</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">1.2 W (typical)</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Low draw — minimal impact on smartphone battery life</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Size (L × W × H)</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">61 × 50 × 12 mm</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Truly pocket-sized; smaller than a standard credit card in length and width</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Weight</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">50 g</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Lighter than most smartphones; no fatigue from extended scanning sessions</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>EMC</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">IEC 61326-1; CISPR 11 Group 1, Class A</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Industrial electromagnetic compatibility standard</td>
</tr>
<tr>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top"><strong>Warranty</strong></td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">2 years</td>
<td class="border-b-0.5 border-[hsl(var(--border-300)/0.3)] py-2 pr-4 align-top">Standard Fluke warranty</td>
</tr>
</tbody>
</table>
</div>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="139:1-139:46;12667-12712"></h3>
<blockquote>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="141:1-141:36;12714-12749"><strong>Q: What is the Fluke iSee ii01?</strong></p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="143:1-143:594;12751-13344">The Fluke iSee™ ii01 is a smartphone-connected acoustic imaging camera that detects compressed air and gas leaks, assesses air tightness, and locates mechanical noise sources. It connects directly to any compatible Android smartphone&#8217;s USB-C port and uses Fluke&#8217;s SoundMap™ beamforming technology to overlay a colour-coded acoustic heat map onto the phone&#8217;s live camera feed in real time. Weighing just 50 g at 61 × 50 × 12 mm, it&#8217;s designed to give individual maintenance technicians access to professional acoustic imaging without the cost or complexity of a dedicated standalone instrument.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="149:1-149:46;13408-13453"><strong>Q: How does acoustic leak detection work?</strong></p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="151:1-151:775;13455-14229">When compressed air or gas escapes through a small gap or fitting, it creates turbulence that produces ultrasonic sound waves above 20 kHz — inaudible to the human ear but detectable by sensitive microphone arrays. The Fluke ii01 captures these signals using 16 high-precision MEMS sensors, calculates the direction and source of the sound through beamforming algorithms, and displays a SoundMap™ acoustic image overlaid on the live camera view, visually pinpointing the leak location. Because most industrial machinery generates low-frequency background noise while gas leaks produce high-frequency ultrasonic signatures, the system can reliably locate leaks even in noisy operating environments, and inspections can usually be conducted while equipment remains in service.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold" data-sourcepos="155:1-155:49;14236-14284">AEO Block 3: What can the Fluke ii01 detect?</h3>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="157:1-157:39;14286-14324"><strong>Q: What can the Fluke ii01 detect?</strong></p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="159:1-159:629;14326-14954">The Fluke ii01 covers a 2 kHz to 48 kHz frequency range, which spans the following applications: compressed air leaks in pneumatic systems and pipework; gas leaks in process pipelines, chemical reactors, and pressure vessels; air tightness assessment of complex pipeline assemblies and sealed equipment; and identification of mechanical abnormal sounds in rotating or pressurised machinery. A dedicated Quick Leak Detection mode locks the frequency band to 37.4–42.6 kHz (optimised for compressed air and gas leak signatures) with a single tap. Real-time dB values at the target centre point provide on-site severity assessment.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="165:1-165:70;15025-15094"><strong>Q: What is the detection range of the Fluke ii01 acoustic camera?</strong></p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="167:1-167:514;15096-15609">The Fluke ii01 supports a detection range of 0.5 m to 50 m, subject to site conditions including ambient noise levels, leak size, and system pressure. The wide-angle field of view (50° × 38°) allows broad area scanning without frequent repositioning, and the focal length covers 50 cm to infinity. This standoff range allows technicians to scan elevated pipework, hard-to-access equipment, or potentially hazardous process areas from a safe working distance while still accurately identifying the acoustic source.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="173:1-173:55;15681-15735"><strong>Q: What smartphones does the Fluke ii01 work with?</strong></p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="175:1-175:458;15737-16194">The Fluke ii01 connects via USB Type-C and is compatible with Android smartphones running Android 6.0 or later, and devices running HarmonyOS 2.0 or later. The OTG (On-The-Go) feature must be enabled on the smartphone. The free Fluke iSee™ application is available for download from the Google Play Store. The ii01 is not compatible with iOS (Apple iPhone) devices. It draws power from the connected smartphone — no separate charging or battery is required.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="181:1-181:87;16278-16364"><strong>Q: How does the Fluke ii01 compare to Fluke&#8217;s higher-end acoustic imaging cameras?</strong></p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="183:1-183:849;16366-17214">The ii01 is Fluke&#8217;s entry-level acoustic imager, designed to make qualitative SoundMap™ imaging accessible to individual technicians at a significantly lower price point than dedicated standalone instruments. It identifies the single strongest sound source (the point with the highest acoustic energy), displays real-time dB readings, and supports full image and video documentation. Fluke&#8217;s higher-tier ii500, ii905, and ii915 series add multi-source acoustic display, preliminary quantitative analysis (LeakQ, PDQ, MecQ modes), wider frequency ranges, and advanced analytics suited to systematic reliability programmes. The ii01 is best suited for individual or team-level compressed air and gas leak detection and air tightness assessments; the higher-tier instruments are suited to large-scale reliability and predictive maintenance programmes.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="189:1-189:66;17275-17340"><strong>Q: What industries is the Fluke ii01 acoustic camera used in?</strong></p>
<p class="font-claude-response-body break-words whitespace-normal" data-sourcepos="191:1-191:701;17342-18042">The Fluke ii01 is used across general manufacturing (compressed air leak detection and noise location); metallurgy, gas, and chemical processing (process gas and hazardous gas pipeline inspection); food, beverage, and pharmaceutical production (air tightness and hygiene-critical maintenance); power generation; hospital and healthcare facilities (oxygen station and pipeline inspection); and equipment manufacturing including compressors, refrigeration systems, and energy storage devices. In Australia, it&#8217;s particularly relevant for industrial maintenance teams, facilities managers, EHS compliance officers, and product quality engineers responsible for maintaining sealed or pressurised systems.</p>
</blockquote>
<p>The post <a href="https://rapid-tech.com.au/fluke-isee-ii01-acoustic-imaging-camera/">Fluke iSee ii01 Acoustic Imaging Camera | Smartphone Leak Detector | Australia</a> appeared first on <a href="https://rapid-tech.com.au">rapid-tech</a>.</p>