Yokogawa WT500 Mid-Range Power Analyzer

Yokogawa_logo_sml

The Yokogawa WT500 Power Analyzer is a Mid Range product for single-phase and three-phase power measurements. It is designed into a compact half-rack size chassis which can also be double rack mounted. Standard features include a colour TFT display and USB interface for communications and memory. The instrument has a basic accuracy of 0.1%, maximum inputs of 1000 Vrms, 40 Arms and a measurement bandwidth of DC to 100 kHz.

Features:

Simultaneous measurement of voltage, current, power, and harmonics
 High-speed data updating (100 ms)
 Display of numerical values, waveforms and trends
 Measurement of bought and sold watt hours
 Easy setup and operation

Current range: 0.5 to 40 A
Voltage range: 15 to 1000 V
Basic Power Accuracy: 0.1%
frequency range: DC 0.5 Hz to 100 kHz

PDF Logo    WT500 Brochure

 

If you would like more information regarding this product, simply email us here.
  • This field is for validation purposes and should be left unchanged.
SKU: Yokogawa WT500 Categories: , Tags: ,

The Yokogawa WT500 is a sophisticated power Analyzer with fast acquisition rate ideal for analyzing harmonics to the 100th order and transients. The WT500 can display inputs as waveforms, trends and in vector or bargraph format. Versatile integration functions such as active power (WP), current (q), reactive power (WQ), and apparent power (WS), and measurement of bought and sold watt hour. The Yokogawa WT500 can display, analyze and evaluate your power, making it an indispensable tool for Green IT, Energy Star and CO2 reduction.

The Yokogawa WT500 is designed for small current measurement in energy-saving equipment, as well as evaluating currents for large-sized loads. The WT500 works with voltages ranging from 1.5 V up to 1000 V, supporting a wide range of applications. Because it can accept signal inputs for up to six phases, a signal WT500 unit can measure I/O signals on inverters.

Yokogawa WT500 Features:

  • Simultaneous measurement of DC and AC signals
    Evaluation of DC/AC signal conversion technology is critical in the renewable energy market. With input from 2 or more elements, the WT500 can measure DC and AC signals simultaneously and calculate input-to-output efficiency.
  • Separate integration functions for charge/discharge and bought/sold power
    The WT500 is equipped with integration functions that can not only evaluate charge and discharge current such as from secondary cells, but also bought and sold power in photovoltaic power generation systems.
  • Saving measured data directly to USB memory
    Measured data can be saved in CSV format directly to USB memory.
  • Easy setup with cursor keys
    Menu-type screen offers intuitive setting.
  • Simultaneous measurement of normal data and harmonic data with the harmonic measurement, /G5 option
    RMS voltage, RMS current, power values, and harmonic components up to the 50 order can be measured simultaneously.

    Yokogawa WT500 Power Meter Specifications:
    Model 760201 760203 760203
    Number of elements 1 element 2 elements 3 elements
    Available with 40A input element
    Basic power accuracy: 0.1% of reading +0.1% of range
    DC power accuracy 0.1% of reading +0.1% of range
    Power frequency range: DC, 0.5 Hz to 100 kHz
    V / A frequency range: 100 kHz
    Sampling Speed: approximately 100 kS/s
    Accuracy range for V / A: 1% to 110%
    Inputs Crest Factor: Maximum 300
    Voltage
    (for crest factor 3) 15 V, 30 V, 60 V, 100 V, 150 V, 300 V, 600 V, 1000 V
    (for crest factor 6) 750m, 1.5, 3, 5, 7.5, 15, 30, 50, 75, 150, 300, 500V
    Direct Input: Current
    40 A input element
    (for crest factor 3) 500 mA, 1 A, 2 A, 5 A, 10 A, 20 A, 40 A
    (for crest factor 6) 250 mA, 500 mA, 1 A, 2.5 A, 5 A, 10 A, 20 A
    External Input: Current Sensor
    (for crest factor 3) 50 mV, 100 mV, 200 mV, 500 mV, 1 V, 2 V, 5 V, 10 V
    (for crest factor 6) 25 mV, 50 mV, 100 mV, 250 mV, 500 mV, 1 V, 2.5 V, 5 V
    Data Memory
    Data memory: approximately 20 MB (internal), HDD
    Data Update
    Rate: 100 m, 200 m, 500 m, 1, 2, 5 [S]
    Measurement Parameters
    Main: Voltage, current, active power, reactive power, apparent power, power factor, phase angle, frequency, peak voltage, peak current, crest factor, integration (Wh, Ah, varh, Vah)
    MAX hold
    Voltage RMS/MEAN simultaneous measurement
    Average active power (user defined function)
    Active power integration (WP) (Wh)
    Apparent power integration (WS) (VAh)
    Reactive power integration (WQ) (varh)
    Motor evaluation Power Consumption of Various Motor Loads
    Delta Calculation Voltage (V) difference, 3P3W ⇒ 3V3A, ΔY, YΔ
    Current (A) difference, 3P3W ⇒3V3A , ΔY, YΔ
    Power (W) Δ Y
    Harmonic Measurement in Normal Measurement Format PLL synchronization
    Frequency PLL source of fundamental frequency : 10 Hz–1.2 kHz.
    Window Rectangular
    FFT data length 8192
    Display—-
    Display: 5.7-inch VGA TFT colour LCD, 640 × 480 dots (H × V)
    Waveform Display
    Numerical: Select 4, 8, 16, Matrix, ALL, Harmonic Single List, Harmonic Dual List, Custom
    Bar: Displays the size of each harmonic in a bar graph
    Vector: Vector display of phase difference in fundamental waves of voltage and current
    Trend display: Number of measurement channels Up to 8 parameters
    Displays trends (transitions) in numerical data of the measurement functions in a sequential line graph.
    Waveform: Displays the waveforms of voltage, current, torque, speed etc.
    Environment
    Power supply: 100 to 90VAC/264 to 240VAC (automatic switching) — 50/60Hz
    Power consumption: Max 80 VA
    Operating Temperature: 5 to 40°C, 20 to 80% RH
    Dimensions: Approximately 213 (W) x 177 (H) x 409 (D) mm
    Weight: Approx. 6.5 kg (main unit with 3 power modules installed)