Yokogawa CL360 200mA/1000A Leakage Current Clamp-On Meters

Yokogawa_logo_sml

The Yokogawa CL360 Clamp-on meter features a large clamp that can measure conductors up to 69 mm in diameter and a leakage current range from 200mA and a maximum current range of 1000AAC, ideal for regular current measurement and high resolution for leakage detection.

  • Leakage current measurement with current range from 200mA to 1000A.
  • AC and DC output.
  • 68mm in diameter of measurable conductor.
  • Mean value display.
  • Manual range switching.
  • Approved for conformity to safety standards EN61010-1, EN61010-2-032
    (CAT III 300V) (CAT II 600V)

 

 

If you would like more information regarding this product, simply email us here.
  • This field is for validation purposes and should be left unchanged.
SKU: Yokogawa CL360 Category: Tags: ,

Yokogawa CL360 Features:

  • Leakage current measurement with current range from 200mA to 1000A
  • Method of detection Mean Value
  • Display LCD (Digital display: 1999 counts)
  • Response Time Approx. 1 second
  • Range Switching Manual-range
  • Data hold On all range
  • Operating temperature and humidity -10 – 50°C , 80% RH or less (no condensation)
  • Safety Standard Conforms EN61010-1, EN61010-2-032
  • Circuit voltage 300 Vrms or less
  • Withstanding voltage 3.7 kV AC for one minute
  • Power Supply 6 LR61 x 1, 6F22 (006P) 9V x 1
  • Battery Life Approx. 60 hours (continuous)
  • Consumed current Approx. 5 mA
  • Diameter of measurable conductor 68 mm at maximum
  • Dimensions Approx. 129 (W) x 248 (H) x 55 (D) mm
  • Weight Approx. 570 g
  • Accessories Batteries, carrying case (93031), User’s manual
  • Peak Hold On all range

Specifications:

Parameter Reference Accuracy
WIDE(40~1kHz) 50/60Hz
AC Current 20mA/2A/20A 1.0+2 (50/60Hz) 3.0+2 (40~1kHz) 1.5+2
200A 1.5+2 (50/60Hz) 3.5+2 (40~1kHz) 2.0+2
1000A(0~500A) 1.5+2 (50/60Hz) 3.5+2 (40~1kHz) 2.0+2
1000A(501~1000A) 5.0 (50/60Hz) 10.0 (40~1kHz) 5.5
AC Output 20mA/2A/20A(0~200mV) 2.0 2.0
200A(0~200mV) 2.5 2.5
1000A(0~50mV/0~500A) 3.0 3.0
1000A(50~100mV/501~1000A) 5.0 5.0
DC Output 20mA/2A/20A(0~200mV) 3.0 3.5
200A(0~200mV) 3.5 4.0
1000A(0~50mV/0~500A) 5.0 5.5
1000A(50~100mV/501~1000A) 7.0 7.5
  • General Specifications

Parameter Specification
Method of Detection Mean Value
Diameter of Measurable conductor Ø68MM at maximum
Display LCD (Digital Display: 1999 Counts)
Response Time (Approx.) 1 Second
Range Switching Manual-Range
Data Hold On All range
Peak Hold On All range
Ambient Temperature and Humidity -10-50˚C, 80% RH or less (no condensation)
Influence of external Magnetic Field 15mA or less  in proximity to a 10-Dia conductor carrying 100A
Influence of Conductor Position 2% or less
Influence of Residual Current 10mA or less  in proximity to a 10-Dia conductor carrying 100A
Circuit Voltage 300Vrms or less
Withstanding Voltage 3.7kV AC for one minute
Power Supply  6F22(006P)9V x1 or 6LR61 x1
Battery Life Approx. 60 hours (continuous)
Consumed Current Approx. 5mA
Auto Power-off
Dimensions Approx. 129(W)x248(H)x55(D)mm
Weight Approx. 570g
AC/ DC Output Option Included

Reviews


There are no reviews yet.

Be the first to review “Yokogawa CL360 200mA/1000A Leakage Current Clamp-On Meters”