Yokogawa CL340 40mA/400A Leakage Current Clamp-On Meters

http://www.amkhamry.cz/?foravil=%D8%A7%D8%B3%D8%B9%D8%A7%D8%B1-%D8%B4%D8%B1%D8%A7%D8%A1-%D9%88%D8%A8%D9%8A%D8%B9-%D8%A7%D9%84%D8%B0%D9%87%D8%A8-%D8%A8%D8%A7%D9%84%D8%B3%D8%B9%D9%88%D8%AF%D9%8A%D8%A9-%D8%A7%D9%84%D9%8A%D9%88%D9%85&699=c0 اسعار شراء وبيع الذهب بالسعودية اليوم Yokogawa_logo_sml

http://sejrup-it.dk/?centosar=%D8%A7%D9%84%D9%81%D8%A7%D8%A6%D8%B6-%D8%A7%D8%B3%D9%87%D9%85-%D8%A7%D8%B3%D9%85%D9%86%D8%AA-%D8%A7%D9%85-%D8%A7%D9%84%D9%82%D8%B1%D9%89&0b1=74 The Yokogawa CL340 Clamp-on tester provides an easy-to read, 3999 count display. It measures current from 40 mA to 400 AAC.  It is an inexpensive, accurate and robust dedicated leakage meter with a mid-size clamp diameter  that accepts conductors up to 44 mm diameter.

Applications

  • Preventative maintenance
  • Testing for current leakage on branch circuits
  • Measuring current draw of motors and motor control circuits
  • Measuring Loads

استراتيجيات وتكتيكات الخيارات الثنائية ابي cofnas قوات الدفاع الشعبي  

If you would like more information regarding this product, simply email us here.
  • This field is for validation purposes and should be left unchanged.
SKU: Yokogawa CL340 Category: Tags: ,

Yokogawa CL340 Features

  • Mean value display
  • Auto power-off
  • Manual range switching
  • Approved for comformity to safety standards EN61010-1, EN61010-2-032 (CAT. III 300 V)

Specifications

Parameter
Reference
Accuracy
WIDE(20Hz to)
50/60Hz
AC Current 40mA/400mA 2.5+10 (20 to 1kHz) 1.0+5 (50/60Hz)
400A(0 to 350A) 2.5+10 (40 to 1kHz) 1.0+5 (50/60Hz)
400A(350 to 400A) 5.0 (40 to 1kHz) 2.0 (50/60Hz)
At 23 deg.C ±5 deg.C, 85% RH or less
Accuracy: ±(% rdg + dgt) = ±(% readout + value of least significant digit)

مزيد من المساعدة  

Method of detection Mean value
Display LCD(Digital display:3999 counts)
Response Time Approx. 2 seconds
Range Switching Manual-range
Data Hold On all range
Peak Hold On all range
Ambient temperature and humidity 0 to 40 deg.C, 85% RH or less (no condensation)
Temperature Coefficient _
Influence of external magnetic field 10mA or less in proximity to a 15mm-dia conductor carrying 100A
Influence of conductor position 40/400mA range:Within 5dgt at every part inside the jaw400A range
0 to 250A:Within ±0.5%rdg ±5dgt at every part inside the jaw section
Influence of residual current 12mA or less in proximity to a 10mm-dia conductor carrying 100A
Safety Standard Conforms EN 61010-1, EN61010-2-032
Circuit Voltage 300Vrms or less
Withstanding Voltage 3.7kV AC for one minute
Power Supply R0-3(UM-4) × 2 or LR03 × 2
Battery Life Approx. 40 hours (continuous)
Consumed Current Approx. 13mA
Auto power-off Approx. 10 minutes
Diameter of measurable conductor 40mm at maximum
Dimensions Approx. 81(W) × 185(H) × 40(D)mm
Weight Approx. 270g
Accessories User’s manual(IM CL340), batteries, carrying case(93030)