Reed ST-156 Coating Thickness Gauge and Probes

reed logo red

The Reed ST-156 Coating Thickness Meter is suitable for the following applications: Inspection of paint thickness, Automotive Industry, Plating Thickness, General Industrial, Manufacturing. Thanks to its Dual technology REED ST-156 Coating Meter provides automatic recognition for ferrous (F) and non-ferrous (NF) metal substrates. Reed ST-156 has capability to save up to 80 readings in 4 different slots, displays statistics (average, minim, maxim values of measurements or standard deviation) and has capability to measure in continuous or single mode.
REED ST-156 can be connected to a personal computer and using the dedicated software ( included) can generate graph or export data to Excel for further data analysis.

PDF   REED ST-156 Instruction Manual

Authorised Australian Distributor

1 Year Warranty

If you would like more information regarding this product, simply email us here.
  • This field is for validation purposes and should be left unchanged.
SKU: REED ST-156 Categories: , , Tags: ,

REED ST-156 Features

  • Dual technology provides automatic recognition for ferrous and nonferrous metal substrates
  • Magnetic induction for ferrous metal substrates
  • Eddy current measurement for non-ferrous metal substrates
  • One or two point calibration
  • User-settable high/low alarms
  • Easy Zero calibration
  • Min, Max, and Average functions
  • Memory stores up to 400 readings
  • Easily delete single or group readings
  • Auto-Power-off function Backlight
  • Measurement Range: 0 to 1250 μm (0 to 49 mils)

How to use Reed ST-156 Coating Thickness Gauge

Continuous Measuring Mode
In Continuous Mode, the probe is not lifted off the surface being measured. Readings are not accompanied by a beep. All readings taken in this mode are automatically entered into the statistics program as long as sufficient memory is available.

Single Measuring Mode
In Single Mode, the probe is lifted off the surface being measured and moved. Readings are accompanied by a beep. All readings taken in this mode are automatically entered into the statistics program as long as sufficient memory is available.

Probe Operating
The probe can work in three modes:
AUTO: The probe can automatically select the working mode. When placed on steel (magnetic substrates), it will work in magnetic induction principle. When placed on no-ferrous metals, it will work in eddy current principle.
Fe: The probe works in magnetic induction principle.
No-Fe: The probe works in eddy current principle.

Statistic View
While in the Menu, choose “Statistic View” to toggle between Average, Maximum, Minimum and Standard Deviation functions. Press the Red Bar Button to select the current Statistic View and to return to measurement mode. A corresponding symbol of the Statistic View will be displayed on the lower right of the LCD. At the same time, the statistic number of the measured readings will display on the lower left of the LCD. Via the “Statistic View” in the Menu, you can look through all statistic values for a current group.

Measurement View
In the Menu, choose “Measurement View” to look through all measurement readings for current group.

REED ST-156 Specifications

Measuring Range 0 to 1250µm
0 to 49.21mils
Accuracy 0 to 850µm: ±3% +1µm
850 to 1250µm: ±5%
0 to 33.46mils: ±3% +0.039mils
33.46 to 49.21mils: ±5%
Resolution 0 to 50µm: 0.1µm
50 to 850µm: 1µm
850 to 1250µm: 0.01mm
0 to 1.968mils: 0.001mils
1.968 to 33.46mils: 0.01mils
33.46 to 49.21mils: 0.1mils
Min. Curvature Radius F: 1.5mm
NF: 3mm
Min. Area Diameter F: 7mm
NF: 5mm
Min. Substrate Thickness F: 0.5mm
NF: 0.3mm
Power Supply 2 x 1.5V “AA” batteries
Dimensions 110 x 50 x 23mm
Weight 100g

 

Reviews


There are no reviews yet.

Be the first to review “Reed ST-156 Coating Thickness Gauge and Probes”