Kyoritsu 4102A-H Earth Tester – Hard Case Model

http://www.trendlux.sk/?qwerara=%D8%AD%D8%B3%D8%A7%D8%A8-%D9%81%D9%88%D8%B1%D9%83%D8%B3-%D8%AA%D8%AC%D8%B1%D9%8A%D8%A8%D9%8A&de5=d5 Kyoritsu_Logo_main

مزيد من التلميحات The Kyoritsu 4102A-H tester performs three-pole earth resistance and two-pole voltage testing of electrical equipment and systems wiring and grounding to reduce power quality issues and avoid safety hazards. The meter is small and lightweight, with shock-resistant case material and taut-band movement. The OK light verifies proper connection between auxiliary earth resistance and lead wire connection to terminals. The tester warns the user when the resistance of auxiliary earth spikes exceeds tolerance. Ground-resistance meters are used by electricians and contractors working in industrial, utility, and field servicing.

Kyoritsu 4102A-H Earth Tester Features:

انتقلت الى هنا • The latest circuit design permits the instrument to operate
with the minimum of influence from earth voltage
and earth resistance of auxiliary earth spikes.
• Dust and drip proof. (designed to IEC 529 IP54)
• Earth resistance value can be read directly from the scale.
• Designed to meet IEC 61010-1 safety standard.
• Capable of measuring earth voltage.
• Small and lightweight. Shock resistant new case material.
• 2mA measuring current permits earth resistance tests
without tripping earth leakage current breakers
in the circuit under test.
• Lead wire connection to C and P terminals and proper
auxiliary earth resistance can be checked by “OK” lamp.
Lead wire connection to C and E terminals is good
when “OK” lamp is illuminated.
• Hard Carry Case

pdf_sml    Kyoritsu 4102A_4105A Datasheet

pdf_sml    Kyoritsu 4102A User Manual

If you would like more information regarding this product, simply email us here.
  • This field is for validation purposes and should be left unchanged.

http://highstxray.com.au/?pyzo=%D8%AA%D8%AF%D8%A7%D9%88%D9%84-%D8%A7%D8%B3%D9%87%D9%85-%D8%B4%D8%B1%D9%83%D8%A9-%D9%88%D9%88%D9%84-%D9%85%D8%A7%D8%B1%D8%AA&a6f=21 The Kyoritsu 4102A Earth Tester is capable of testing earth resistance up to 1200Ω. This can be achieved via the 2 pole or 3 pole method with the supplied accessories.

http://c-pages.co.uk/?komis=%D8%B4%D8%B1%D9%83%D8%A7%D8%AA-%D8%A7%D9%84%D8%AA%D8%AF%D8%A7%D9%88%D9%84-%D9%81%D9%8A-%D8%A7%D9%84%D8%A7%D9%85%D8%A7%D8%B1%D8%A7%D8%AA&1d0=b7 The Kyoritsu 4102A Earth Tester is designed so that the influence of the earth voltage and earth resistance of the auxiliary spikes are neglected under the earth resistance test. A low measuring current of 2mA allows earth resistance tests to be performed without tripping earth leakage current breakers. The Kyoritsu 4102A Earth Tester also has the ability to measure earth voltage, up to 30V AC.

جعلت الخيارات الثنائية سهلة Small and lightweight, the Kyoritsu 4102A Earth Tester is both dust and drip proof, conforming to the IP54 standard. The instrument is also shock resistant and designed to meet IEC 61010-1 safety standard. The Kyoritsu 4102A-H Earth Tester is supplied with earth resistance test leads, measurement probe, auxiliary spike kit, batteries, a shoulder strap and a hard carry case.

Kyoritsu 4102A-H Earth Tester Specifications:

Measurement ranges Earth Resistance: 0 – 12 Ω/0 – 120 Ω/0 – 1200 Ω
Earth Voltage [50,60Hz]: 0 – 30V AC
Accuracy Earth Resistance: ±3% of full scale
Earth Voltage: ±3% of full scale
Overload protection Earth Resistance: 276V AC for 10 seconds
across 2 of the 3 terminals
Earth Voltage: 276V AC for 1 minute
Applicable standards IEC 61010-1 CAT III 300V Pollution Degree 2, IEC 61557
IEC 60529 IP54
Power source R6 (AA) (1.5V) × 6
Dimensions 105(L) × 158(W) × 70(D)mm
Weight 600g approx.
Included Accessories 7095A (Earth resistance test leads) × 1set
(red-20m, yellow-10m, green-5m)
8032 (Auxiliary earth spikes) × 1set
7127A (Simplified measurement probe) × 1set
R6 (AA) × 6
9121 (Shoulder strap)
Instruction Manual
Carrying case : : 9164 (Carrying case[Hard])
Optional Accessories 7100A (Precision measurement cord set)