Extech CO250 Portable Indoor Air Quality CO2 Meter

Extech logo

Measures Carbon Dioxide (CO2)

This Portable Indoor Air Quality CO2 Meter measures Carbon Dioxide (C02), Temperature, Humidity, Dew Point, and Wet Bulb. Checks for Carbon Dioxide (CO2) concentrations and calculates statistical weighted averages of TWA (8 hour time weighted average) and STEL (15 minute short term exposure limit). User programmable audible alarm. Data acquisition software and cable included to record and document CO2, Humidity and Temperature data. Complete with software and cable, 4 AA batteries, and carrying case.

CE   1 Year

PDF Logo    تعلم هذا هنا الآن  CO250 datasheet
PDF Logo     تحقق من ذلك CO250_User Manual
If you would like more information regarding this product, simply email us here.
  • This field is for validation purposes and should be left unchanged.
SKU: Extech CO250 Categories: , Tags: ,
ثنائي الخيار إكس بي Extech CO250 Portable Indoor Air Quality CO2 Features:
  • Checks for Carbon Dioxide (CO2) concentrations
  • Calculates statistical weighted averages of TWA (8 hour time weighted average) and STEL (15 minute short term exposure limit)
  • Maintenance free NDIR (non-dispersive infrared) CO2 sensor
مزيد من التلميحات CO2 Guidelines:
اخر اخبار الفوركس Non-Enforced Reference levels:
  • 250 – 350 ppm – background (normal) outdoor air level
  • 350- 1,000 ppm – typical level found in occupied spaces with good air
  • 1,000 – 2,000 ppm – level associated with complaints of drowsiness and poor
  • 2,000 – 5,000 ppm – level associated with headaches, sleepiness, and stagnant, stale, stuffy air. Poor concentration, loss of attention, increased heart rate and slight nausea may also be
  • >5,000 ppm – Exposure may lead to serious oxygen deprivation resulting in permanent brain damage, coma and even

http://onsiteinsights.co.uk/?kliwe=%D8%A7%D9%84%D8%AE%D9%8A%D8%A7%D8%B1%D8%A7%D8%AA-%D8%A7%D9%84%D8%AB%D9%86%D8%A7%D8%A6%D9%8A%D8%A9&364=f2 Regulatory exposure limits:

ASHRAE Standard 62-1989: 1000ppm: CO2 concentration in occupied building should not exceed 1000ppm.

OSHA: 5000ppm: Time weighted average over five 8-hour work days should not exceed 5000ppm

Building bulletin 101 (Bb101): 1500ppm. UK standards for schools say that CO2 at averaged over the whole day(i.e. 9am to 3.30 pm) should not exceed 1500ppm.

Germany, Japan, Australia, UK…: 5000ppm, 8 hours weighted average in occupational exposure limit is 5000ppm.

Extech CO250 Specifictions:

http://scottishpen.org/?pywka=%D8%A7%D9%84%D8%AE%D9%8A%D8%A7%D8%B1%D8%A7%D8%AA-%D8%A7%D9%84%D8%AB%D9%86%D8%A7%D8%A6%D9%8A%D8%A9-%D8%A7%D9%84%D8%AA%D8%AF%D8%A7%D9%88%D9%84-%D9%84%D8%A7-%D8%A5%D9%8A%D8%AF%D8%A7%D8%B9&3bf=4c Function http://mydaddycooks.com/?evropa=%D9%85%D9%83%D8%A7%D8%AA%D8%A8-%D8%A8%D9%8A%D8%B9-%D8%A7%D9%84%D8%A7%D8%B3%D9%87%D9%85-%D8%A7%D9%84%D9%83%D9%88%D9%8A%D8%AA&0f1=4b Range دعوة ثنائية الخيار آلة حاسبة Resolution http://www.dramauk.co.uk/?arapyza=%D9%85%D8%B6%D8%A7%D8%B1%D8%A8-%D8%A7%D9%84%D9%81%D9%88%D8%B1%D9%83%D8%B3&904=88 Accuracy
مصدر المقال  

توقعات بيع اسهم مجموعة الحكير CO2

0 to 5000ppm 1ppm ±(%5rdg + 50ppm)
5000 to 9999ppm 1ppm Not specified
Pressure dependence: +1.6% reading per kPa deviation from normal pressure, 100kPa
تصفح حول هذا الموقع Temperature -10 to 60°C

14 to 140°F

0.1° ±0.6°C/0.9°F
http://cantabsrowing.org.uk/?semecko=%D8%A7%D9%84%D8%AF%D9%8A%D9%86%D8%A7%D8%B1-%D8%A7%D9%84%D8%B9%D8%B1%D8%A7%D9%82%D9%8A-%D9%84%D9%84%D9%81%D9%88%D8%B1%D9%83%D8%B3&b91=59 Humidity 0.0 to 99.9% 0.1% ±3%(10 to 90%)

±5%(< or > 10 to 90%)

http://etonvintners.com/?aliserto=%D8%A7%D9%81%D8%B6%D9%84-%D8%B4%D8%B1%D9%83%D8%A7%D8%AA-%D8%A7%D9%84%D9%81%D9%88%D8%B1%D9%8A%D9%83%D8%B3&936=79 Wet Bulb -5 to 60°C

23 to 140°F

0.1° http://rbsc.org.uk/?rimonibot=%D9%85%D8%AA%D9%8A-%D8%B7%D8%B1%D8%AD-%D8%A7%D8%B3%D9%87%D9%85-%D8%A7%D9%84%D8%A8%D9%86%D9%83-%D8%A7%D9%84%D8%A7%D9%87%D9%84%D9%8A&985=f5  

Calculated from RH and Temperature

http://ufsverige.org/?firty=kostnad-forex&5a0=f9 Dew Point -20 to 60°C

-4 to 140°F

0.1°

الخيارات الثنائية مقابل تداول الأسهم   Display                   Triple LCD with backlight

Sensor Type                   

  • CO2: NDIR (non-dispersive infrared) technology
  • Humidity: Capacitance sensor; Temperature (air): Thermistor

Operating Conditions    0 to 50C (32 to 122F); < 95% RH non-condensing

Storage Conditions    -20 to 60C ( -4 to 140F); <99% RH non-condensing

Power Supply    4 x 1.5V ‘AA’ batteries or AC adaptor (9V/1A)

Battery Life approx. 24 hours (alkaline batteries)

Dimensions / Weight      200 x 70 x 57mm / 190g